NFPA Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment (FAE-AAC) May 31 June 2, 2017 Providence, RI

Size: px
Start display at page:

Download "NFPA Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment (FAE-AAC) May 31 June 2, 2017 Providence, RI"

Transcription

1 NFPA Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment (FAE-AAC) May 31 June 2, 2017 Providence, RI Meeting Call-In Information: Participant Code: May 31, :00am 1. Call to Order, Bill Haskell, Chair 2. Introductions by Members and Guests 3. NFPA Staff Liaison Report, Chris Farrell 4. Approval of Minutes from Previous Meeting 5. Chairman s Remarks, Bill Haskell (ANSI/ASSE Z88 Respirator Committee & ISO SC15 USTAG Updates) 6. Overall PPE Project/Standards Schedule, Chris Farrell 7. Definitions Task Group, Karen Lehtonen 8. NFPA Certified Product with Non-Compliant Technologies/Systems/Equipment, Bob Athanas 9. Firefighter Hazard Environment Task Group, Dan Rossos & Marni Schmid 10. Eye, Face and Head Protection for Emergency Responders, Standard Development, Robert Tutterow 11. FPRF Project and Project Technical Panel Updates, Casey Grant 12. PFOA Discussion Bruce Varner 13. ISO TC94 SC13 Protective Clothing, SC14 Firefighters personal equipment Update, David Matthews, Russell Shephard, Diane Hess and Steve Corrado 14. NFPA Technical Committee Standard Reports First Draft NFPA 1975, J. Metz NFPA 1851, S. King Second Draft NFPA 1981, D. Rossos NFPA 1982, R. Athanas NFPA 1855, J. Metz NFPA 1858, J. Metz 15. Technical Committee Chair Reports TC on ELS R. Athanas TC on EMS T. Hock TC on HAZ C. Baxter TC on RPE D. Rossos TC on SCE J. Metz TC on SPF S. King TC on TTO B. Montgomery TC on WFF R. Swan 16. Old Business 17. New Business 18. Next Meeting 19. Adjourn

2 First Draft Meeting of the Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment December 13 th, 2016 Adobe Connect/Teleconference Minutes Introduction: Bill Haskell, Chair 11:00 a.m. Members and Guests Jason Allen Steve Corrado Christine Fargo Bill Haskell (Chair) David Haston Diane Hess James Johnson Karen Lehtonen David Matthews Benjamin Mauti John Morris Jeff Stull Tim Tomlinson Robert Tutterow Bill Van Lent Bruce Varner Steve Weinstein Dick Weise Pat Freeman Tim Gardner Judge Morgan Tricia Hock Brian Montgomery Dan Rossos Rick Swan Marni Schmid (guest) Chairman s Remarks Bill Haskell NFPA Staff Liaison Report Chris Farrell Approval of Minutes from the previous meeting Task Group Updates (as appropriate) 1. Definitions Task Group Karen Lehtonen: No update about definitions. 2. Labeling Task Group Karen Lehtonen: Group can be disbanded since analysis was reported in the chart at the last Correlating committee meeting. Group was disbanded. No further update from Karen.

3 3. Firefighter Hazard Environment Task Group Dan Rossos: no new update. 4. Hood Safety Alert Task Group Bruce Varner: Ed Conlin, Division Manager of Public Fire, updated that NFPA working on a communication. Cannot be called a safety notice, have to use a different name. Possibly use a tip sheet format with 3-4 takeaway items they want firefighters to know. Draft document will be provided to the Task Group for review after NFPA legal review, but prior to publication. 5. Eye and Face Protection Task Group Robert Tutterow: Task group continues to work on the end user survey. Eye and face selection for 1851 draft language being worked on. ISO Update Dave Matthews 6. Harry Winer s task group: no action taken since last CC meeting. Chapter 5 User Information Format Steve Corrado: Attach to packaging containing the user information. Didn t foresee widespread use of QR codes and smart phones. Asking for clarification regarding whether a physical printed copy is required or if a link to electronic documents is acceptable. Bill will follow up with the NFPA regarding where the clarification should be made (CC or NFPA FI) NFPA 1852, 1989 First Draft Review Technical Committee Chair Reports a. TC on ELS: R. Athanas b. TC on EMS: T. Hock c. TC on HAZ: C. Baxter d. TC on RPE: D. Rossos e. TC on SCE: J. Metz f. TC on SPF: S. King g. TC on TTO: B. Montgomery h. TC on WFF: R Swan Old Business New Business Next Correlating Committee Meeting, dates and location Somewhere on the east coast near Boston: Providence, RI Portsmouth, NH Portland, ME Adjourn

4 National Fire Protection Association 1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M TO: FROM: Technical Committee on Structural and Proximity Fire Fighting Protective Clothing and Equipment Yvonne Smith, Project Administrator DATE: May 30, 2017 SUBJECT: NFPA 1851 First Draft Technical Committee FINAL Ballot Results (F2018) According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. 35 Members Eligible to Vote 3 Members Not Returned (Ott, Putorti, Jr., Sisson) The attached report shows the number of affirmative, negative, and abstaining votes as well as the explanation of the vote for each revision. To pass ballot, each revision requires: (1) a simple majority of those eligible to vote and (2) an affirmative vote of 2 /3 of ballots returned. See Sections (c) and of the Regulations Governing the Development of NFPA Standards.

5 First Revision No. 77 NFPA [ Global Input ] Change manufacturer trained organization to manufacturer trained organization Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 17:43:08 EDT 2017 Committee Statement Committee Statement: Global language change Response Message: Public Input No. 118 NFPA [Global Input] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. 1/286

6 Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 2/286

7 First Revision No. 80 NFPA [ Global Input ] Replace routine cleaning with On Scene (Preliminary) Cleaning Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 18:22:51 EDT 2017 Committee Statement Committee Statement: This proposed change reflect a terminology change separately recommended. Response Message: Public Input No. 206 NFPA [Global Input] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn 3/286

8 Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 4/286

9 First Revision No. 2 NFPA [ Section No ] This standard shall also specify the minimum selection, care, and maintenance requirements for structural fire fighting protective ensembles with optional CBRN liquid and particulate contamination protection and for proximity fire fighting protective ensembles with optional CBRN liquid and particulate contamination protection. Supplemental Information File Name FR_2_1.1.4.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 17:27:53 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 45 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. 5/286

10 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 6/286

11 First Revision No. 3 NFPA [ Section No ] This standard shall also apply to structural fire fighting protective ensembles with optional CBRN liquid and particulate contamination protection and to proximity fire fighting protective ensembles with optional CBRN liquid and particulate contamination protection. Supplemental Information File Name FR_3_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:22:25 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 46 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 7/286

12 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 8/286

13 First Revision No. 4 NFPA [ Section No ] This standard shall not apply to respiratory protective equipment other than where such equipment interfaces with structural fire fighting protective ensembles or proximity fire fighting protective ensembles with the optional CBRN liquid and particulate contamination protection. Supplemental Information File Name FR_4_1.3.4.docx Description Approved For staff use. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:24:31 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 47 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 9/286

14 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 10/286

15 First Revision No. 5 NFPA [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered part of the requirements of this document. 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA NFPA 600, Standard on Industrial Facility Fire Brigades, edition. NFPA 1500, Standard on Fire Department Occupational Safety and Safety Health, and Wellness Program, edition. NFPA 1951, Standard on Protective Ensembles for Technical Rescue Incidents, edition. NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, edition. NFPA 1972, Standard on Helmets for Structural Fire Fighting, 1992 edition. NFPA 1973, Standard on Gloves for Structural Fire Fighting, 1993 edition. NFPA 1974, Standard on Protective Ensembles for Proximity Fire Fighting, 1992 edition. NFPA 1976, Standard on Protective Ensembles for Proximity Fire Fighting, 2000 edition. NFPA 1977, Standard on Protective Clothing and Equipment for Wildland Fire Fighting, edition. NFPA 1991, Standard on Vapor Protective Ensembles for Hazardous Materials Emergencies, edition. NFPA 1992, Standard on Liquid Splash Protective Ensembles and Clothing for Hazardous Materials Emergencies, edition. NFPA 1994, Standard on Protective Ensembles for First Responders to Hazardous Materials Emergencies and CBRN Terrorism Incidents, edition. NFPA 1999, Standard on Protective Clothing and Ensembles for Emergency Medical Operations, edition. 2.3 Other Publications ACGIH Publications. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH ACGIH Publication No. 0107, 2007 TLVs and BEIs ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM D737, Standard Test Method for Air Permeability of Textile Fabrics, ASTM E2274, Standard Test Method for Evaluation of Laundry Sanitizers and Disinfectants, ASTM E2406, Standard Test Method for Evaluation of Laundry Sanitizers and Disinfectants for Use in High Efficiency Washing Operations, /286

16 2.3.2 ISO Publications. International Organization for Standardization, ISO Central Secretariat 1, ch. de la Voie Creuse, Case postale 56, CH 1211 Genève 20, Switzerland, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva, Switzerland. ISO 17011, Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies, ISO/IEC Guide 65, General requirements for bodies operating product certification systems, ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories, ISO/IEC 17065, Conformity assessment Requirements for bodies certifying products, processes and services, U.S. Government Publications. U.S. Government Printing Publishing Office, 710 North Capitol Street, NW, Washington, DC NIOSH Publication No , NIOSH Pocket Guide to Chemical Hazards, September EPA Product Performance Test Guidelines OCSPP : Disinfectants and Sanitizers for Use on Fabrics and Textiles Efficacy Data Recommendations Other Publications. Lewis, R., Hazardous Chemicals Desk Reference, John Wiley & Sons, New York, Merriam Webster s Collegiate Dictionary, 11th edition, Merriam Webster, Inc., Springfield, MA, References for Extracts in Mandatory Sections. (Reserved) Supplemental Information File Name FR_5_ch._2.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:27:37 EDT 2017 Committee Statement Committee Statement: Updating references. Response Message: Public Input No. 7 NFPA [Chapter 2] Public Input No. 197 NFPA [Section No. 2.3] Public Input No. 99 NFPA [Chapter 2] 12/286

17 Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. 13/286

18 Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 14/286

19 First Revision No. 6 NFPA [ Section No ] Advanced Cleaning. See , Advanced Cleaning. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:44:08 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee would like the definition to be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 110 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 15/286

20 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 16/286

21 First Revision No. 7 NFPA [ Section No ] 3.3.5* Carcinogen/Carcinogenic. A cancer causing substance that is identified in one of several published lists, including, but not limited to, those prepared by NIOSH Pocket Guide to Chemical Hazards, Hazardous Chemicals Desk Reference, and the ACGIH 2007 TLVs and BEIs the U.S. National Toxicology Program, the International Agency for Research on Cancer (IARC), the National Institute for Occupational Safety and Health (NIOSH), and the American Conference of Governmental Industrial Hygienists (ACGIH). Supplemental Information File Name FR_7_3.3.5.docx FR 7_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:49:35 EDT 2017 Committee Statement Committee Statement: Response Message: The proposed changes update the definition and expand the sources for identifying carcinogens. A related annex item is separately provided to given actual source lists. The proposed annex item provides a source for lists of different carcinogens. These changes are consistent with the intent of modifying the definition and creating a separate annex section for specific sources (published lists) Public Input No. 194 NFPA [Section No ] Public Input No. 145 NFPA [Section No ] Public Input No. 148 NFPA [New Section after A.3.2.4] Public Input No. 195 NFPA [New Section after A.3.2.4] Ballot Results This item has passed ballot 35 Eligible Voters 17/286

22 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard 18/286

23 Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 19/286

24 First Revision No. 8 NFPA [ Section No ] 3.3.8* CBRN Barrier Layer. The part of the composite that is intended to provide protection against CBRN terrorism agents. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 18:58:48 EDT 2017 Committee Statement Committee This section and its related annex section are no longer needed as the CBRN option has Statement: been removed from NFPA 1971 and there are no certified ensembles that meet these optional requirements. Response Message: Public Input No. 48 NFPA [Section No ] Public Input No. 58 NFPA [Section No. A.3.3.8] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All 20/286

25 Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 21/286

26 First Revision No. 9 NFPA [ Section No ] Cleaning. The act of removing soils soiling and contaminants contamination from ensembles and ensemble elements by mechanical, chemical, thermal, or combined processes * Routine On Scene (Preliminary) Cleaning. The light cleaning of ensembles or ensemble elements performed at or near the emergency scene or as soon as possible by the end user without taking the elements out of service * Advanced Cleaning. The thorough cleaning of ensembles or elements by washing with cleaning agents * Specialized Cleaning. Cleaning to remove hazardous materials or, body fluids, or other forms of contamination. Supplemental Information File Name FR_9_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:04:12 EDT 2017 Committee Statement Committee The current hierarchy of cleaning definitions is not consistent with actual practice or the Statement: approach that is needed to reduce the spread of persistent contamination following emergency operations. The proposal of the term on scene cleaning is intended to connote that cleaning must start as soon as possible following the exit from the fire ground or other emergency area. Response Message: Additional detail is needed in the annex to explain the role of on scene or preliminary cleaning and indicate the practical limitations for its application. Public Input No. 204 NFPA [Section No ] Ballot Results This item has passed ballot 22/286

27 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. 23/286

28 Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 24/286

29 First Revision No. 11 NFPA [ Section No ] * Contamination/Contaminated. The process by which ensembles and ensemble elements are exposed to hazardous materials, body fluids accumulation of hazardous materials on or in an ensemble element that includes carcinogenic, toxic, corrosive, or sensitizing chemicals, potentially infectious body fluids, other infectious microorganisms, or CBRN terrorism agents. Supplemental Information File Name FR_11_3.3.15_plus_annex.docx FR 11_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:16:51 EDT 2017 Committee Statement Committee A clearer, more robust definition is needed for contamination that identifies other forms of Statement: potential contaminants. The definition has also been made consistent with soiling. An annex section is separately recommended to provide further explanation of the definition. The annex language further clarifies the process of contamination and its significance. Response Message: Public Input No. 143 NFPA [Section No ] Public Input No. 144 NFPA [New Section after A ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 25/286

30 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. 26/286

31 OK 27/286

32 First Revision No. 12 NFPA [ Section No ] * Disinfectant. An A type of antimicrobial agent that destroys, neutralizes, or inhibits the growth of harmful biological agents or irreversibly inactivates microorganisms on hard, inanimate surfaces and objects. Supplemental Information File Name FR_12_3.3.22_plus_annex.docx FR 12_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:25:50 EDT 2017 Committee Statement Committee The definition for disinfectant is consistent with the definition provided by the EPA Statement: regarding the classification of antimicrobial agents. An annex item is separately provided to provide further clarification of the definition. Response Message: The annex language related to the definition of disinfectant clarifies how a disinfectant is qualified and its relative effectiveness. Public Input No. 18 NFPA [New Section after 3.3] Public Input No. 13 NFPA [Global Input] Public Input No. 150 NFPA [New Section after A ] Public Input No. 149 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 28/286

33 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. 29/286

34 Affirmative with Comment Granger, Jr., Richard O. OK 30/286

35 First Revision No. 13 NFPA [ Section No ] Independent Service Provider (ISP). An independent third party utilized by an organization to perform advanced cleaning, advanced inspection, and repair services. In order to comply with NFPA 1851, an ISP must be verified. [ See also , Verified Independent Service Provider (ISP)]. Supplemental Information File Name FR_13_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:35:59 EDT 2017 Committee Statement Committee The TC acknowledges that the definition was removed in the 2014 edition because the Statement: committee did not want to imply that an ISP could comply with the standard without being verified. This definition addresses that issue while providing a basic, generic definition of an ISP. Response Message: Public Input No. 109 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. 31/286

36 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 32/286

37 First Revision No. 14 NFPA [ Section No ] Major A Seam. See , Major A Seam. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:39:21 EDT 2017 Committee Statement Committee Statement: Response Message: The definition should be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 111 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 33/286

38 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 34/286

39 First Revision No. 15 NFPA [ Section No ] Major B Seam. See , Major B Seam. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:40:52 EDT 2017 Committee Statement Committee Statement: Response Message: The definition should be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 112 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 35/286

40 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 36/286

41 First Revision No. 17 NFPA [ Section No ] Manufacturer Trained Organization. See , Manufacturer Trained Organization. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:49:22 EDT 2017 Committee Statement Committee Statement: Response Message: The definition should be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 113 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 37/286

42 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 38/286

43 First Revision No. 16 NFPA [ Section No ] Minor Seam. See , Minor Seam. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:47:33 EDT 2017 Committee Statement Committee Statement: Response Message: The definition should be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 114 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 39/286

44 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 40/286

45 First Revision No. 19 NFPA [ Section No ] Proximity Fire Fighting Protective Ensemble with Optional CBRN Terrorism Agent Liquid and Particulate Contamination Protection. A compliant proximity fire fighting protective ensemble that is also certified as an entire ensemble to meet the optional requirements for protection from specific CBRN terrorism agents liquid and particulate contaminants. Supplemental Information File Name FR_19_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:05:28 EDT 2017 Committee Statement Committee This term has been revised to be consistent with the new edition of NFPA 1971 and Statement: addresses the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 49 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. 41/286

46 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 42/286

47 First Revision No. 20 NFPA [ Section No ] Routine On Scene (Preliminary) Cleaning. See , On Scene (Preliminary) Cleaning. Supplemental Information File Name FR_20_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:19:18 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee would like the definition to be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 115 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 43/286

48 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 44/286

49 First Revision No. 22 NFPA [ Section No ] * Soiled/ Soiling. The accumulation of materials that are not considered hazardous materials, body fluids, or CBRN terrorism agents but that could degrade the performance of the ensemble or ensemble elementsweat, dust, dirt, debris, and other nonhazardous materials on or in an ensemble or ensemble element sweat, dust, dirt, debris, and other nonhazardous materials on or in an ensemble or ensemble element that could degrade its performance or cause hygiene issues. Supplemental Information File Name FR_22_3.3.87_plus_annex.docx FR 22_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:27:08 EDT 2017 Committee Statement Committee The current definition does not define what soiling is but instead what it is not. The Statement: proposed definition provides a clearer description of soiling. A separate annex section is being recommended to clarify the definition of soiling. "Soiled" does not need to be defined as it is the action of soiling. Response Message: Additional clarification is needed for the definition of soiling, particularly in how soiling is different from contamination. This additional information also indicates how ordinary fireground exposures to combustion products are actually a form of contamination. Public Input No. 141 NFPA [Section No ] Public Input No. 142 NFPA [New Section after A ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 45/286

50 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. 46/286

51 Affirmative with Comment Granger, Jr., Richard O. OK 47/286

52 First Revision No. 21 NFPA [ Section No ] Specialized Cleaning. See , Specialized Cleaning. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:23:55 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee would like the definition to be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 116 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 48/286

53 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 49/286

54 First Revision No. 23 NFPA [ Section No ] Structural Fire Fighting Protective Ensemble with Optional CBRN Terrorism Agent Liquid and Particulate Contaminant Protection. A compliant structural fire fighting protective ensemble that is also certified as an entire ensemble to meet the optional requirements for protection from specific CBRN terrorism agents liquid and particulate contaminants. Supplemental Information File Name FR_23_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:36:24 EDT 2017 Committee Statement Committee This term has been revised to be consistent with the new edition of NFPA 1971 and Statement: addresses the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 50 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. 50/286

55 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 51/286

56 First Revision No. 24 NFPA [ Section No ] Structural Fire Fighting Protective Hood. The interface element of the protective ensemble that provides limited protection to the coat/helmet/scba facepiece interface area. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:41:15 EDT 2017 Committee Statement Committee Statement: Response Message: Ballot Results Particulate contamination blocking layers are available in the market place. There is currently no information in the standard to address these articles of PPE for the end user. This item has passed ballot 35 Eligible Voters 3 Not Returned 30 Affirmative All 2 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. 52/286

57 Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK Stull, Jeffrey O. I do not see the need to remove this definition as there are still hoods with and without the optional particulate blocking performance 53/286

58 First Revision No. 26 NFPA [ Section No ] Verified Organization. See , Verified Organization. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:59:50 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee would like the definition to be consistent with other definitions that point the reader to another section by naming the test in the referenced section. Public Input No. 117 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 54/286

59 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 55/286

60 First Revision No. 18 NFPA [ New Section after ] * Sanitizer. A type of antimicrobial agent that kills or irreversibly inactivates at least 99.9 percent of all microorganisms present on a surface. Supplemental Information File Name FR_14_3.3.x_plus_annex.docx FR 18_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 19:58:36 EDT 2017 Committee Statement Committee Statement: Response Message: The definition of sanitizer is needed to differentiate its antimicrobial activity against a disinfectant. The proposed term is consistent with the EPA definition of a sanitizer. The annex item further elaborates on the definition of a sanitizer. The changes for addressing both disinfectants and sanitizers are in line with the previously proposed changes to NFPA 1851 that were held during the public comment period during the last revision and included as public inputs 13 and 18. Public Input No. 152 NFPA [New Section after A ] Public Input No. 151 NFPA [New Section after ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 56/286

61 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment 57/286

62 Granger, Jr., Richard O. OK 58/286

63 First Revision No. 25 NFPA [ New Section after ] * Structural Fire Fighting Particulate Blocking Hood. A structural fire fighting protective hood that reduces particulate penetration. Supplemental Information File Name FR_25_3.3.x_particulate_hood.docx FR 25_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 20:52:30 EDT 2017 Committee Statement Committee Statement: Response Message: Particulate contamination blocking layers are available in the market place. There is currently no information in the standard to address these articles of PPE for the end user. Public Input No. 174 NFPA [New Section after A ] Public Input No. 140 NFPA [New Section after ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 59/286

64 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 60/286

65 First Revision No. 42 NFPA [ New Section after ] * Mitigation. A technique for reducing soiling and contamination from the exterior of the ensemble or ensemble element that takes place during on scene or preliminary cleaning. Supplemental Information File Name FR_42_3.3.x_mitigation_plus_new_annex.docx FR 42_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 10:54:08 EDT 2017 Committee Statement Committee The transformation of the routine cleaning procedures to procedures for on scene or Statement: preliminary cleaning. The new procedures require the use of a new term for mitigation as form of on scene cleaning. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 61/286

66 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 62/286

67 First Revision No. 28 NFPA [ Section No ] Manufacturer trained organizations performing advanced cleaning and advanced inspection shall be trained by an element manufacturer of the same element type or by a verified ISP. Organizations that wish to perform advanced cleaning and advanced inspection shall be trained by an element manufacturer of the same element type or by a verified ISP. The element manufacturer or verified ISP shall provide documentation that the organization has received the necessary training. Supplemental Information File Name FR_28_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 21:07:43 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee suggests these changes to make the section clearer and easier to understand. The changes do not affect the meaning of the section. Public Input No. 119 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. 63/286

68 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 64/286

69 First Revision No. 29 NFPA [ Section No ] The organization shall compile and maintain records as required by on fire fighting protective ensembles with CBRN liquid and particulate contamination protection. The records shall include a list of specific required elements and interface components necessary for structural fire fighting protective ensembles with optional CBRN terrorism agent liquid and particulate contamination protection and proximity fire fighting protective ensembles with optional CBRN terrorism agent liquid and particulate contamination protection. Supplemental Information File Name FR_29_4.3.4.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 21:10:11 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 51 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. 65/286

70 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 66/286

71 First Revision No. 30 NFPA [ Section No. 4.4 ] 4.4 Manufacturer s Instructions When issuing new structural fire fighting protective ensembles and ensemble elements or proximity fire fighting protective ensembles and ensemble elements, the organization shall provide users with the instructions provided by the manufacturer on the care, use, and maintenance of the protective ensembles or ensemble elements, including any warnings provided by the manufacturer. This information shall be permitted to be delivered from the manufacturer in various formats, including, but not limited to, printed materials or instructions to access the information electronically/digitally * Where the manufacturer s instructions regarding the care or maintenance of the protective ensembles or elements differ from a specific requirement(s) in this standard, the manufacturer s instructions shall be followed for that requirement(s). Manufacturers shall not be permitted to override the requirements of this standard for third party verification The organization shall retain and make accessible to fire department personnel a copy of manufacturers instructions regarding the care, use, and maintenance of the protective ensembles for reference purposes. Supplemental Information File Name FR_30_4.4.1.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 21:14:27 EDT 2017 Committee Statement Committee Statement: Adding language to clarify information can be shared digitally. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 67/286

72 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. 68/286

73 Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 69/286

74 First Revision No. 31 NFPA [ Section No ] 4.5.4* Soiled or potentially contaminated ensembles or ensemble elements shall not be brought into the home, washed in home laundries, or washed in public laundries taken to public facilities, or transported in private vehicles. Supplemental Information File Name FR_31_4.5.4_plus_annex.docx FR 31_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 21:21:05 EDT 2017 Committee Statement Committee The Technical Committee suggests this change to clearly state that the public cannot be Statement: exposed to soil and contaminants. Because the original statement limits the restriction to home, home laundries, and public laundries, it s missing public dry cleaners and all other public places dirty gear should not go (like grocery stores). This language makes the restriction more in line with what the committee intended. Response Message: Public Input No. 120 NFPA [Section No ] Public Input No. 121 NFPA [New Section after 4.5.4] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 70/286

75 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. 71/286

76 OK 72/286

77 First Revision No. 32 NFPA [ Section No ] The organization shall request written acknowledgment from that the report of health and safety concerns was received by the element manufacturer and certification organization. Written acknowledgment must be received within 30 days of the date of the report of health and safety concerns. Supplemental Information File Name FR_32_4.6.3.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Apr 13 21:23:26 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee would like to specify what the written acknowledgement is acknowledging. Public Input No. 122 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 73/286

78 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 74/286

79 First Revision No. 33 NFPA [ Sections 5.1.1, ] 5.1.1* Prior to starting the selection process of structural fire fighting ensembles and ensemble elements and proximity fire fighting ensembles and ensemble elements, the organization shall perform a risk assessment The organization shall distinguish between the use of structural fire fighting ensembles and proximity fire fighting ensembles based on the operating area and mission responsibilities of the organization. The risk assessment shall be based on both the frequency and severity of exposure to specific hazards as a means for determining the selection of appropriate fire fighting protective ensembles The organization shall review the risk assessment or conduct a new risk assessment at least every 2 years or under specific circumstances, including, but not limited to, the following: (1) When there are changes that affect the findings of the current risk assessment in terms of the specific identification of hazards or availability of fire fighting ensemble product technology (2) When there are changes in the organization s standard operating procedures (SOPs) for the use of structural fire fighting ensembles or proximity fire fighting ensembles (3) When any personal protective ensemble or ensemble elements are being considered for selection and purchase The risk assessment shall include, but not be limited to, the hazards that can be encountered by structural or proximity fire fighters based on the following: (1)* Type of duties performed (2) Frequency of use of ensemble elements Distinguishing response activities for different potential incidents (3) Organization s experiences (4) Incident operations (5) Geographic location and climate (6)* Specific physical area of operation (7)* Likelihood of or response to CBRN terrorism incident (8) Need for two sets of ensemble elements or spare ensemble elements Supplemental Information File Name FR_33_ _and_5.1.2.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc 75/286

80 Street Address: City: State: Zip: Submittal Date: Fri Apr 14 08:40:52 EDT 2017 Committee Statement Committee NFPA 1851 addresses the organization s selection of appropriate fire fighting protective Statement: ensembles. Currently, insufficient detail exists within the standard to distinguish between the decision for selecting protective ensembles for either structural or proximity fire fighting. The lack of detail in both the mandatory and non mandatory parts the standards does not provide adequate information for organizations to consider which type of protective ensemble to have available for the respective hazards that the organization may face as part of its firefighting responsibilities. In fact, this deficiency has led some organizations to dismiss the need for proximity fire fighting protective ensembles on the basis of an overly simplistic hazard assessment that does not recognize the specific risks and potential for those fire fighter injury or fatalities in high radiant fire environments, such as aircraft fires. Such hazards require additional radiant protection afforded by proximity fire fighting protective ensembles. Response Message: Outside organizations rely on the specific requirements and guidance provided in NFPA 1851 to support selection decisions that they make. Therefore it is incumbent that the NFPA 1851 standard includes the appropriate provisions to aid in the selection of protective ensembles that are commensurate with the specific hazards and risks faced by the fire fighters. This includes the requirements for different organizations to select structural, proximity, or both types of fire fighting protective ensembles. Public Input No. 42 NFPA [Sections 5.1.1, 5.1.2] Public Input No. 43 NFPA [Sections A.5.1, A.5.1.1, A.5.1.2(1), A.5.1.2(6), A.5.1.2(7)] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. 76/286

81 Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 77/286

82 First Revision No. 37 NFPA [ New Section after ] * Organizations shall specifically consider the tradeoffs in the level of thermal insulation versus thermal comfort or stress related effects of the material composite in their selection of protective garments. Supplemental Information File Name FR_37_ _new_plus_annex.docx FR 37_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 09:24:21 EDT 2017 Committee Statement Committee A substantial decision for organizations in selecting protective garments is to consider the Statement: tradeoffs between the protection from heat and the stress induced by the garment. Thermal protective performance, total heat loss, and evaporative resistance of the principal material composite offer information that is helpful to the fire department. The balance in these properties affects fire department tactics and protection strategies and should be highlighted. It is further proposed that additional language be prepared for the annex that explains the differences in the performance properties and how these properties can be viewed in making decisions on the selection of protective garments. Response Message: Public Input No. 9 NFPA [Global Input] Public Input No. 215 NFPA [New Section after 5.1.5] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 78/286

83 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment 79/286

84 Granger, Jr., Richard O. OK 80/286

85 First Revision No. 38 NFPA [ New Section after ] * Based on the risk assessment, the organization shall ensure that eye and face protection components or separate devices are specified to provide adequate eye and face protection for each type of incident identified in the risk assessment. Supplemental Information File Name FR_38_ _new_plus_annex.docx FR 38_A docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 09:47:40 EDT 2017 Committee Statement Committee Fire fighters may encounter a variety of different eye and face exposure hazards for which Statement: different forms of eye and face protection are needed. While some of this protection may be offered by the SCBA facepiece, the different types of components provided with the helmet, either faceshields, goggles, or both, should be further considered in how the organization determines the suitable ensemble for protecting its members. Response Message: Public Input No. 96 NFPA [New Section after 5.1.6] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned 81/286

86 Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 82/286

87 First Revision No. 39 NFPA [ Section No ] 83/286

88 A /286

89 Organizations are able to assess the effectiveness of ensemble interfaces and interface components for reducing the penetration of particulate contamination by conducting a simple test. In this test, a fire fighter wears their ensemble consisting of protective garments, a helmet, gloves, footwear, a hood, and self contained breathing apparatus (SCBA). A fluorescent agent based solution is sprayed as an aerosol onto the exterior of the protective ensemble worn by the fire fighter, while the fire fighter carries out stationary exercises. When applied as a fine mist, the aerosol can approximate the small particles of smoke created in a structural fire. After carefully removing the ensemble, the underlying skin and clothing are examined under a black UV light to show any evidence of aerosol penetration. This information can then be used by the organization to judge how well interfaces are maintained between elements and the overall protective capabilities of specific interface components such as particulate blocking hoods. For performing this test, the following supplies, equipment, and facilities are needed: (1) A commercial fluorescent liquid solution that is typically applied in hand washing. A supply of 3.8 L (1 gal) will be sufficient to evaluate multiple ensembles. (2) An ordinary paint spray with a variable control. An inexpensive electric powered sprayer can be obtained for less than $100 from a home improvement supply store. (3) A large black UV flashlight for viewing any fluorescent aerosol. Alternatively, a bank of long black UV fluorescent lights can be used in a darkened room. (4) An area that can be darkened for examining the fire fighter test subject under black light. This area can be a closet or other room where the light can be fully blocked out. (5) An area for spraying the liquid onto the fire fighter test subject. (6) Optionally, the fire fighter test subject can wear black witness garments such as body wear underneath the ensemble to provide a uniform viewing surface. If this approach, is used, synthetic material based black body wear consisting of a full long sleeved top and pants are useful. However, such garments must be totally free of lint as ascertained by being checked under a black light. The basic procedures for conducting this test involve the following steps: (1) Spray a very small portion of fluorescent solution (1 sec) onto either the black witness garment or individual s skin to determine how it appears under the selected black light observation conditions. This will serve as a visual control for determining if penetration has occurred. (2) The fluorescent solution should rinse off the individual s skin with thorough soap andwater washing. It should also be readily removed from the black witness garments by conventional washing. (3) If the fire fighter test subject wears the black witness garments, then the garments should be washed and free of lint. (4) Put the fluorescent liquid in the sprayer reservoir and adjust the sprayer settings to deliver a light, circular spray pattern of liquid mist. (5) Have the fire fighter test subject put on the complete ensemble to be evaluated. (6) Spray the fluorescent liquid onto the fire fighter ensemble using a spray time of 5 to 10 seconds in each location. Ideally, have the test subject perform motions that are designed to challenge the interfaces, such as reaching above their head with their arms, bending over, and cross body reaches. (7) Following the spraying of fluorescent liquid, use extreme care removing the ensemble from the fire fighter test subject to prevent contaminant transfer to the interior and skin/clothing of the subject. (8) After the ensemble is removed, check the surfaces on the black witness garments or test subject s skin under a black UV light in a darkened area to determine if there is any visual evidence of fluorescence that might have penetrated from the spraying process. (9) Make notes or draw a diagram to show where underlying fluorescence has penetrated portions of the ensemble or the test subject s skin. 85/286

90 Based on this test method, information gained from the evaluation of different ensembles can show their relative effectiveness in preventing particulate protection. However, it is important to note that this evaluation technique might not show all avenues of particulate penetration and can also provide results that might be difficult to interpret unless specific penetration pathways are identified. It is important to carry out these procedures with a high level of advance planning and scrutiny to ensure consistent and comparable results. For example, conducting the evaluation with the same test subject(s) on the same day will allow more uniform testing when comparing different ensembles. Supplemental Information File Name FR_39_A docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 09:51:07 EDT 2017 Committee Statement Committee Fire departments need simple tests to show how well their ensembles performed to prevent Statement: the inward leakage of particulates to either barrier hoods or complete ensembles. The proposed inspection technique can be easily performed and can be further used as a means for training firefighters on their relative exposures during fire ground operations. In addition, this technique has utility for showing cross contamination that occurs during the doffing process. Response Message: Public Input No. 216 NFPA [Global Input] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 86/286

91 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 87/286

92 First Revision No. 40 NFPA [ Section No ] 5.1.8* Where the organization develops purchase specifications, at least the following criteria shall be included: (1) Purchase specifications shall require that the ensemble or ensemble element(s) to be purchased shall be compliant with the current edition of NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting. Purchasers shall consider that ensembles that are certified to the optional CBRN liquid and particulate contamination protection requirement are tested and certified as ensembles and must be worn as an ensemble with all elements and interface components present as stated on the element label. (2)* Where the organization selects criteria that exceed the minimum requirements of the current edition of NFPA 1971, such criteria shall be stipulated in the purchase specifications. (3)* Purchase specifications shall require that manufacturers submitted offers or bids include substantiation of certification for each element and model stated in the bid offered. (4)* Where applicable, the purchase specifications shall define the process for determining proper fit. (5)* The organization shall compare each bid submittal against purchase specifications. Supplemental Information File Name FR_40_5.1.8.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 10:07:00 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 52 NFPA [Section No ] Ballot Results 88/286

93 This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. 89/286

94 Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 90/286

95 First Revision No. 43 NFPA [ Section No ] Universal precautions shall be observed, as appropriate, when handling ensemble elements. At a minimum, individuals conducting inspections shall wear examination gloves that are certified to NFPA Consideration shall also be given to having individuals conducting inspections of ensemble elements wear appropriate aprons with sleeves or respirators. Supplemental Information File Name FR_43_6.1.1.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 11:00:44 EDT 2017 Committee Statement Committee Universal precautions is a philosophy for assuming that clothing is contaminated unless Statement: other demonstrated. More specific guidance should be provided to departments as to how universal precautions can be applied, which includes the use of protective clothing to limit contamination transfer to the individual conducting the inspection. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. 91/286

96 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 92/286

97 First Revision No. 44 NFPA [ Section No ] The organization shall determine appropriate actions to be taken if an element is found to be in need of cleaning, decontamination, or repair Global FR 80 As At a minimum, any necessary cleaning or decontamination shall be done in accordance with the requirements specified in Chapter 7. Where a condition exists that is beyond on scene (preliminary) cleaning in accordance with Section 7.2, the element shall be removed from service, tagged, and referred to personnel responsible for advanced cleaning As At a minimum, any necessary repairs shall be made in accordance with the requirements specified in Chapter 8. Where a condition exists that is beyond on scene (preliminary) cleaning in accordance with Section 8.3, the element shall be removed from service, tagged, and referred to personnel responsible for repair As At a minimum, any necessary testing shall be conducted in accordance with the methods specified in Chapter 12. Supplemental Information File Name FR_44_6.1.4.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 11:05:31 EDT 2017 Committee Statement Committee Statement: Response Message: This additional requirement provides the end user with more detail on what to do if something is found during the inspection process. There is similar language in NFPA Public Input No. 90 NFPA [Sections , ] Ballot Results This item has passed ballot 93/286

98 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. 94/286

99 Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 95/286

100 First Revision No. 45 NFPA [ Section No ] Individual members shall conduct a routine inspection of their protective ensembles and ensemble elements upon issue, at the beginning of each duty period, and after each use. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 11:11:08 EDT 2017 Committee Statement Committee Statement: Response Message: A routine inspection should also be conducted at the beginning of each duty period to ensure the elements are fit for use. Public Input No. 91 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. 96/286

101 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 97/286

102 First Revision No. 46 NFPA [ Section No ] 6.2.2* The routine inspection shall include, as at a minimum, the inspections specified in through Coat and trouser garment elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage such as the following: (a) (b) (c) Rips, tears, and cuts Damaged or missing hardware and closure systems Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) (4) Damaged or missing reflective trim (5) Loss of seam integrity and broken or missing stitches (6) Correct assembly and size compatibility of shell, liner, and the drag rescue device (DRD) Hood elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage such as the following: (a) (b) Rips, tears, and cuts Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) (4) Loss of face opening adjustment (5) Loss of seam integrity and broken or missing stitches (6)* Damage to the barrier (particulate blocking hoods only) 98/286

103 Helmet elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage to the shell such as the following: (a) Cracks, crazing, dents, and abrasions (b) Thermal damage to the shell (such as bubbling, soft spots, warping, or discoloration) (4) Physical damage to the earflaps such as the following: (a) Rips, tears, and cuts (b) Thermal damage (such as charring, burn holes, or melting) (5) Damaged or missing components of the suspension and retention systems (6)* Damaged or missing components of the faceshield/goggle system, including discoloration, crazing, and scratches to the faceshield/goggle lens limiting visibility (7) Damaged or missing reflective trim (8) Loss of seam integrity and broken or missing stitches Glove elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage such as the following: (a) Rips, tears, and cuts (b) Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) (c) Inverted glove liner (4) Shrinkage (5) Loss of elasticity or flexibility (6) Loss of seam integrity and broken or missing stitches Footwear elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage such as the following: (a) (b) (c) Cuts, tears, and punctures Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) Exposed or deformed protective toe, protective midsole, or shank (4) Loss of water resistance (5) Closure system component damage and functionality (6) Loss of seam integrity and broken or missing stitches 99/286

104 DRD components shall be inspected for the following: (1) Installation in garment (2) Soiling (3) Contamination (4) Physical damage such as the following: (a) (b) (c) Cuts, tears, punctures, cracking, or splitting Thermal damage (such as charring, burn holes, melting, or discoloration) Loss of seam integrity and broken or missing stitches Interface components shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage (4) Loss or reduction of properties that allow component to continue as effective interface [e.g., loss of shape or inability to remain attached to the respective element(s) where attachment is required] (5) Loss of seam integrity and broken or missing stitches Supplemental Information File Name FR_46_6.2.2.docx FR 46_A _6_.docx Description Approved For staff use New annex Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 12:43:53 EDT 2017 Committee Statement Committee Changed the legislative text to match the tables and maintain consistency between the Statement: legislative text and annex for "Inverted glove liner". Particulate blocking Hoods are not currently addressed by 1851, this and other proposed changes address this problem. Response Message: Public Input No. 138 NFPA [Section No ] Public Input No. 123 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 157 NFPA [Section No ] Public Input No. 136 NFPA [Section No ] 100/286

105 Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O /286

106 Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 102/286

107 First Revision No. 48 NFPA [ Section No ] * The ensemble or ensemble element manufacturer or a verified ISP and the organization shall determine the level of training required to perform advanced inspections. The ensemble or ensemble element manufacturer or verified ISP shall provide written verification of training. The organization shall be retrained on advanced inspection procedures by either an element manufacturer or a verified ISP upon each new revision of this standard If the organization is a verified organization, it shall be permitted to determine the level of training necessary to perform the advanced inspection without any further written verification. Supplemental Information File Name FR_48_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 13:39:32 EDT 2017 Committee Statement Committee There have been several changes since the first Edition of 1851, and significant changes to Statement: the next edition are likely. There is, however, no requirement for organizations to receive updated training. This is especially important when considering that this standard is an end user document allowing for organizations to perform cleaning, inspections and basic repairs in house. It should be required that organizations receive training on the most current edition of this standard and stay abreast of any changes to be able to continue to perform in house cleaning, inspections and repairs on their PPE. Response Message: Public Input No. 178 NFPA [Section No [Excluding any Sub Sections]] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 103/286

108 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J /286

109 Affirmative with Comment Granger, Jr., Richard O. OK 105/286

110 First Revision No. 49 NFPA [ Section No ] 6.3.3* Advanced inspections of all protective ensemble elements that are issued shall be conducted at a minimum of every 12 months, or annually and whenever a routine inspections indicate that a problem could exist determines potential damage Ensemble elements that have been properly stored in accordance with Chapter 9 and are not being used are not required to be subjected to advanced inspection. Supplemental Information File Name FR_49_6.3.3.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 13:44:07 EDT 2017 Committee Statement Committee The Complete Liner Inspection is a critical method for evaluating the thermal barrier and Statement: moisture barrier. It is also relatively easy and quick to perform as part of the Advanced Inspection and has become routine practice requested by fire departments. Since the performance of these two components is critical to the performance of the garment, it is appropriate for the Complete Liner Inspection to become a required part of the Advanced Inspection annually. This will both improve the Advanced Inspection and simplify the inspection interval criteria currently written in the standard Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 106/286

111 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment 107/286

112 Granger, Jr., Richard O. OK 108/286

113 Sections] ] First Revision No. 51 NFPA [ Section No [Excluding any Sub The advanced inspection shall include, as at a minimum, the inspections specified in through through and for garment elements only the testing specified in Section 12.1 and Section The complete liner inspection shall be permitted to be conducted as part of the advanced inspection in lieu of the testing specified in Section 12.1 and Section Supplemental Information File Name FR_51_6.3.5.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 14:47:10 EDT 2017 Committee Statement Committee The Light Test was originally included in the Standard to provide an easy method of Statement: evaluating the thermal barrier without opening the liner assembly. At the time, the rationale was sound. Now, however, after several years of experience with NFPA1851, we have learned the Light Test is neither easy to conduct or as effective as opening the liner up and visually inspecting all layers for possible issues. The inclusion of this test in the Standard, along with the Complete Liner Inspection, also adds confusion to the inspection process. The Complete Liner Inspection is clearly the more effective method for evaluating the thermal barrier. It is also relatively easy and quick to perform. Since the performance of the thermal barrier is critical to the performance of the garment, it is appropriate for the Complete Liner Inspection to become a required part of the Advanced Inspection. This will both improve the Advanced Inspection and simplify the inspection criteria. The Puddle Test was originally included in the Standard to provide an easy method of evaluating of the moisture barrier without opening the liner assembly or having the ability to perform the hydrostatic test. At the time, the rationale was sound. Now, however, after several years of experience with NFPA1851, we have learned the Puddle Test is neither easy to conduct or as effective as opening the liner up and performing the hydrostatic test. The inclusion of this test in the Standard, along with the Complete Liner Inspection, also adds confusion to the inspection process and is a very time consuming task and further more is not used commonly in the industry. The Hydrostatic Test as the recommended procedure to evaluate leakage of the moisture barrier while performing the Complete Liner Inspection is clearly the more effective method for evaluating the moisture barrier layer. It is also relatively easy and quick to perform. Since the performance of the moisture barrier is critical to the performance of the garment, it is appropriate for the hydrostatic test to be the recommended leakage evaluation within the Complete Liner Inspection. This will both 109/286

114 Response Message: Ballot Results improve the Advanced Inspection and simplify the inspection criteria. This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom 110/286

115 Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 111/286

116 First Revision No. 55 NFPA [ Section No ] * Hood elements shall be inspected for the following: (1) Soiling (2) Contamination (3) Physical damage such as the following: (a) (b) (c) (d) (4) Shrinkage Rips, tears, and cuts Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) Damage to the internal moisture barrier, thermal barrier, or any other barrier material Damage or separation of any material designed to function as a barrier as determined in Sections 12.1 through 12.5 (5) Loss of material elasticity or stretching out of shape (6) Loss of seam integrity or broken or missing stitches (7) Loss of face opening adjustment (8)* Label integrity and legibility (9) Any damage to the particulate blocking layer (particulate blocking hoods only) Supplemental Information File Name FR_55_ _plus_annex_material.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 15:07:49 EDT 2017 Committee Statement Committee Statement: Response Message: Barrier hoods are not addressed by the current edition. This adds text to address those products Public Input No. 139 NFPA [Section No ] Public Input No. 159 NFPA [Section No ] 112/286

117 Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 30 Affirmative All 2 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O /286

118 Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Affirmative with Comment Granger, Jr., Richard O. OK Woods, Patrick J. In regard to the addition of (9), the word "Any" should not be included in the sentence. The preceding numbers (1) (7) all deal with integrity or functionality issues, but do not contain the word "any'. This should also be the same in Table A last item(fr 47) 114/286

119 First Revision No. 58 NFPA [ Section No ] Glove elements shall be inspected for the following: (1) Soiling (2) Contamination (3)* Physical damage such as the following: (a) Rips, tears, and cuts (b) Thermal damage (such as charring, burn holes, melting, or discoloration of any layer) (c) Inverted glove liner (d) Loss of seam integrity or broken or missing stitches (4) Shrinkage (5) Loss of flexibility (6) Loss of elasticity and shape in wristlets (7) Accessories for compliance with (8)* Label integrity and legibility Supplemental Information File Name FR_58_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 16:31:44 EDT 2017 Committee Statement Committee Statement: Response Message: Changed the legislative text to match the tables and maintain consistency between the legislative text and annex for "Inverted glove liner" Public Input No. 137 NFPA [Section No ] Ballot Results This item has passed ballot 115/286

120 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A /286

121 Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 117/286

122 First Revision No. 59 NFPA [ Section No ] Additional Advanced Inspection Criteria for Ensembles with Optional CBRN Liquid and Particulate Contamination Protection * CBRN Liquid and particulate contamination protective ensembles shall be inspected according to the manufacturer s instructions Complete liner inspection of all garment elements shall be conducted at a minimum after 2 years in service and annually thereafter or whenever advance inspections indicate that a problem might exist CBRN Liquid and particulate contamination protective ensembles shall be inspected for loss of integrity, including but not limited to the following : (1) Loss of interface functionality (2) Excessive material or component shrinkage or stretching Supplemental Information File Name FR_59_6.3.7.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 16:35:42 EDT 2017 Committee Statement Committee The CBRN option has been removed from NFPA 1971 and there are no certified ensembles Statement: that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Given the fact that analogous issues exist with respect to particulate/liquid barriers as with CBRN barrier layers, the same types of consideration should be provided for inspection of the optional liquid and particulate protection ensemble elements. Response Message: Public Input No. 53 NFPA [Section No ] Ballot Results 118/286

123 This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D /286

124 Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 120/286

125 First Revision No. 50 NFPA [ Section No ] Complete liner inspection of all garment elements shall be conducted as part of the advanced inspection at a minimum after 3 years in service and annually thereafter or and whenever a problem might exist routine inspection determines potential damage. The liner system shall be opened to expose all layers for inspection and testing A complete liner inspection of all garment elements shall be conducted after 2 years in service and annually thereafter following replacement of the moisture barrier, the CBRN barrier, or both. Supplemental Information File Name FR_50_6.4.3.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 13:51:55 EDT 2017 Committee Statement Committee The Complete Liner Inspection is a critical method for evaluating the thermal barrier and Statement: moisture barrier. It is also relatively easy and quick to perform as part of the Advanced Inspection and has become routine practice requested by fire departments. Since the performance of these two components is critical to the performance of the garment, it is appropriate for the Complete Liner Inspection to become a required part of the Advanced Inspection annually. This will both improve the Advanced Inspection and simplify the inspection interval criteria currently written in the standard Response Message: Public Input No. 191 NFPA [Section No. A.6.4.3] Public Input No. 179 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 192 NFPA [Section No. A ] Public Input No. 54 NFPA [Section No ] Public Input No. 180 NFPA [Section No ] Ballot Results This item has passed ballot 121/286

126 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A /286

127 Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 123/286

128 First Revision No. 62 NFPA [ Section No. 7.1 ] 7.1* General Organizations shall provide a means for having ensemble elements cleaned and decontaminated Organizations shall establish specific capabilities and procedures for cleaning and decontaminating ensemble elements from soiling and expected contamination. These capabilities shall be permitted to be provided by one or more verified ISPs As part of providing a means for having ensemble elements cleaned and decontaminated, organizations shall use the decision tool provided in Figure (a) and Figure (b). Figure (a) Approach for Deciding Handling, Cleaning, and Disposition of Ensemble Elements. Figure (b) Approach for Addressing Specific Types of Contamination Organizations shall determine their specific limitations for carrying out cleaning and decontamination of ensemble elements internally and identify a means by which these limitations can be addressed /286

129 Ensembles and ensemble elements shall be evaluated by the wearer or a designated individual within the organization for application of appropriate cleaning level after each use Ensembles and ensemble elements contaminated by CBRN terrorism agents shall be immediately retired after confirmed exposure and shall not be subjected to cleaning or decontamination Ensembles and ensemble elements that were used in a hazardous materials incident shall be assessed by qualified members of the hazardous materials team or other experts with knowledge about the specific exposures that took place. The information gained from the hazardous materials team or other experts shall be used to determine whether cleaning is possible. If a determination is made that cleaning is possible, an appropriate form of specialized cleaning shall be applied for removal of contamination from the affected ensembles and ensemble elements. If a determination is made that cleaning is not possible, the affected ensembles and ensemble elements shall be retired and not subjected to cleaning or decontamination * Ensembles and ensemble elements that are known or suspected to be contaminated with hazardous materials shall be evaluated on the incident scene by members of the organization authorized by the organization to conduct a preliminary assessment of the extent of contamination and the need for ensembles or ensemble elements to be isolated, tagged, and bagged on scene, and the type of cleaning or decontamination that is to be applied as specified in This evaluation shall apply to ensembles and ensemble elements that are used in a structural fire that cannot be completely cleaned on scene Ensembles and ensemble elements that are soiled but not contaminated shall be subject to on scene (preliminary cleaning) as specified in Section * Eye and face protection components that are provided as part of the helmet or as separate devices shall be cleaned after each use Where ensembles have been suspected or found to have contamination from bulk chemicals, asbestos, or other designated hazardous materials, body fluids, or other forms of biological contamination, and combustion products or soot, the organization shall follow the steps based on Figure (a) and the steps described in through as applied to the specific form of contamination suspected or confirmed to be present Contaminated ensembles and ensemble elements shall be isolated during the incident personnel decontamination process and removed from service until the contaminant or suspected contaminant is identified and the elements can receive specialized cleaning as necessary to remove the specific contaminant(s) If spare ensembles or ensemble elements are not available, the organization shall provide other forms of clothing to minimize any cross contamination to the apparatus, other vehicles, station, or other facilities until any uniform or underlying clothing can be cleaned * Where possible and where the contaminant and its source have been identified, the organization shall consult the supplier of the contaminant and the manufacturer of the ensemble and ensemble elements for an appropriate decontamination agent and process /286

130 A member(s) of the organization who has received training in the cleaning of ensembles and ensemble elements shall be responsible for performing or managing specialized cleaning of elements contaminated with hazardous materials Where ensembles or ensemble elements have been exposed to asbestos or other designated highly hazardous substances, the exposure shall be evaluated by members of the organization authorized by the organization to conduct a preliminary assessment of the extent of the contamination and if the exposure warrants cleaning and reuse of the ensemble. If the determination is made that cleaning and decontamination need to be performed, then the respective ensemble elements shall be subjected to an appropriate form of specialized cleaning Ensembles and ensemble elements that are known or suspected to be contaminated with body fluids or other forms of biological contaminants shall be evaluated on the incident scene by members of the organization authorized to conduct a preliminary assessment of the extent of contamination and need for the ensemble or ensemble elements to be isolated, tagged, and bagged at the incident scene * Organizations shall have written procedures detailing the decontamination and cleaning processes for ensembles and ensemble elements contaminated with body fluids or other forms of biological contaminants. Where used, these processes shall employ only disinfectants or sanitizers that have been registered and properly validated as to the specific claims of disinfection and sanitization. Selected disinfectants and sanitizers shall not degrade the performance properties of protective ensemble elements. Any disinfectant used on clothing ensemble elements shall be validated for its effectiveness as specified in Universal precautions shall be observed at all times by members handling elements known or suspected to be contaminated with body fluids Ensembles and ensemble elements that have been significantly exposed to combustion products shall be assumed to be contaminated and shall be subjected to on scene (preliminary) cleaning, isolation, tagging, and bagging at the incident scene. The exposure shall be evaluated by members of the organization authorized by the organization to conduct a preliminary assessment of the extent of the contamination and if the exposure warrants either advanced cleaning or specialized cleaning. If the determination is made that specialized cleaning is needed, then the respective ensemble elements shall be subjected to an appropriate form of specialized cleaning Ensembles and ensemble elements contaminated by CBRN terrorism agents shall be immediately retired after confirmed exposure and shall not be subjected to cleaning or decontamination * Ensembles and ensemble elements that are known or suspected to be contaminated with hazardous materials shall be evaluated on the incident scene by members of the organization authorized by the organization to conduct a preliminary assessment of the extent of contamination and the need for ensemble or ensemble elements to be isolated, tagged, and bagged on scene Contaminated ensembles and ensemble elements shall be isolated during the incident personnel decontamination process and removed from service until the contaminant or suspected contaminant is identified and the elements can receive specialized cleaning as necessary to remove the specific contaminant(s) /286

131 * Where possible and where the contaminant and its source have been identified, the organization shall consult the supplier of the contaminant and the manufacturer of the ensemble and ensemble elements for an appropriate decontamination agent and process A member(s) of the organization who has received training in the cleaning of ensembles and ensemble elements shall be responsible for performing or managing specialized cleaning of elements contaminated with hazardous materials Ensembles and ensemble elements that are known or suspected to be contaminated with body fluids shall be evaluated on the incident scene by members of the organization authorized to conduct a preliminary assessment of the extent of contamination and need for the ensemble or ensemble elements to be isolated, tagged, and bagged at the incident scene * Organizations shall have written procedures detailing the decontamination and cleaning processes for ensembles and ensemble elements contaminated with body fluids. Universal precautions shall be observed at all times by members handling elements known or suspected to be contaminated with body fluids Soiled or contaminated elements shall not be brought into the home, washed in home laundries, or washed in public laundries unless the public laundry has a dedicated business to handle protective ensembles and ensemble elements * Commercial dry cleaning shall not be used as a means of cleaning or decontaminating ensembles and ensemble elements unless approved by the ensemble or ensemble element manufacturer * When a verified ISP is used for cleaning or decontamination, the verified ISP shall demonstrate to the organization s satisfaction that the procedures for cleaning and decontamination do not compromise the performance of ensembles and ensemble elements * Selected cleaning processes employed by the organization or verified ISP shall not knowingly cause significant long term degradation of ensemble or ensemble element performance when applied at the expected frequency When elements of an ensemble are connected, the procedures in and shall be used When one element is connected to another element and they are not permanently attached to each other, individual elements shall be disassembled from each other prior to beginning the cleaning process of elements and all disassembled elements shall undergo a separate cleaning process When one element is connected to another element and they are not permanently attached to each other and are subsequently disassembled from each other prior to beginning the cleaning process, they shall be reassembled prior to any return to service in a like manner to their original manufactured state. Supplemental Information 127/286

132 File Name FR_62_7.1.docx FR 62_7.1_Annex_changes.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 12:34:19 EDT 2017 Committee Statement Committee Extensive changes are proposed for this section to reflect work and discussion by the Statement: NFPA 1851 task group on cleaning of protective ensembles. The principal change involves defining a decision process by which determinations are made on the handling, potential for cleaning, and disposition of the ensemble and ensemble elements using a hierarchy of cleaning approaches. The changes reflect the incorporation of the new concepts with existing language within NFPA It is recognized that additional work will be required to more effectively establish specific requirements by which organizations can apply effective cleaning for the removal of soiling and contamination. Response Message: The current language provided in A is now tied to A.7.1. Additional changes to this section have been made to address special cleaning of eyewear, the recognition that products of combustion should be considered contamination, and the cleaning of ensembles when elements are connected to one another. Public Input No. 97 NFPA [New Section after 7.1.2] Public Input No. 207 NFPA [Section No. 7.1] Public Input No. 214 NFPA [Section No. A.7.1.9] Public Input No. 39 NFPA [Section No ] Public Input No. 200 NFPA [New Section after 7.2] Public Input No. 198 NFPA [New Section after 7.1.9] Public Input No. 208 NFPA [Global Input] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 30 Affirmative All 1 Affirmative with Comments 1 Negative with Comments 0 Abstention 128/286

133 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Affirmative with Comment Granger, Jr., Richard O /286

134 OK Negative with Comment Woods, Patrick J. This negative vote does not reflect a disagreement with the concept of increasing the protection of fire service members from multiple and varied forms of contamination, especially the need to limit the exposure to cancer causing toxins. However, nothing in the committee statement technically justifies the proposed changes to 7.1. The Committee Statement for this revision is based on a discussion of a TC Task Group. What was discussed? The TC needs to explain the reason for the changes and technical justification for addressing each specific type of contamination. It must also reflect the data driving the benefit of addressing each type of contamination. As 7.1 has significant cost implications, it stands to reason that some form of sound technical justification is warranted to require the listed action triggers. Arguably, the TC statement fails to meet the spirit of the NFPA s Regulations Governing Committee Projects /286

135 First Revision No. 63 NFPA [ Section No. 7.2 ] 7.2* Routine On Scene (Preliminary) Cleaning * Organizations shall include on scene or preliminary cleaning as part of their overall program for the selection, care, and maintenance of structural fire fighting ensembles and ensemble elements and proximity fire fighting ensembles and ensemble elements * The end End users shall be responsible for the routine on scene (preliminary) cleaning of their issued ensemble and ensemble elements Organizations shall examine the manufacturer s product label and user information for instructions on or precautions for on scene (preliminary) cleaning and drying that the manufacturer provided with the ensemble or ensemble element. In the absence of manufacturer s instructions or manufacturer s approval of alternative procedures for the ensemble or ensemble element, the routine on scene (preliminary) cleaning and drying procedures provided in this section shall be used Routine On Scene (Preliminary) Cleaning Process * Where possible, the contamination levels shall be evaluated and organizations shall direct their members to initiate on scene (preliminary) cleaning shall be initiated at immediately after exiting the emergency scene * Ensembles and element layers shall be isolated whenever possible to avoid cross contamination. Upon exiting the emergency scene, the end user shall remain on self contained breathing apparatus (SCBA) air or switch to ambient air if the cylinder is empty Any If the end user is returning to the emergency scene after an air cylinder change, any dry debris shall be brushed off the helmet, facepiece, and SCBA prior to changing out the cylinder * If the end user is completing their time on scene, dry or wet mitigation shall occur prior to the removal of any ensemble or ensemble elements * Dry mitigation shall be performed by brushing debris from the exterior of ensembles and ensemble elements prior to removal * Wet mitigation shall be performed by gently rinsing off the exterior of ensembles and ensemble elements Other debris, shall be gently rinsed with a fine mist of water. Heavy scrubbing or spraying with high velocity water jets such as a power washer shall not be used Where necessary, a soft bristle brush shall be used to gently scrub, and the ensemble or element shall be rinsed off again during the wet mitigation process If used in combination, dry mitigation shall precede wet mitigation /286

136 * Following dry or wet mitigation, the ensemble or ensemble elements shall be isolated and bagged if they are determined to be contaminated as specified in Where on scene (preliminary) cleaning fails to render the ensemble or ensemble element(s) sufficiently clean from soiling for service, the ensemble or ensemble element(s) shall receive advanced cleaning Other debris shall be gently rinsed off with water. Heavy scrubbing or spraying with highvelocity water jets such as a power washer shall not be used Where necessary, a soft bristle brush shall be used to gently scrub, and the ensemble or element shall be rinsed off again Where necessary, elements for routine cleaning shall be cleaned in a utility sink designated for personal protective equipment (PPE) cleaning and decontamination using the following procedures: * Heavily soiled or spotted areas shall be pretreated. Chlorine bleach, chlorinated solvents, active ingredient cleaning agents, or solvents shall not be used without the ensemble or element manufacturer s approval. * Water temperature shall not exceed 40 C (105 F). Mild detergents with a ph range of not less than 6.0 ph and not greater than 10.5 ph as indicated on the product MSDS or original product container shall be used. * Protective gloves and eye/face splash protection shall be worn. Element(s) shall be gently scrubbed using a soft bristle brush. Element(s) shall be thoroughly rinsed. Element(s) shall be inspected and, where necessary, shall be rewashed or submitted for advanced cleaning procedures. The manufacturer shall be consulted if stronger cleaning agents are required. Elements shall be dried in accordance with Section 7.4. Following the routine cleaning procedure, the utility sink shall be rinsed Additional Requirements for Routine Cleaning of Garment Elements Routine cleaning procedures for cleaning garment elements shall be used only for spot cleaning of the element and shall be performed in a utility sink To avoid cross contamination, garment element layers shall be isolated whenever possible Cleaning of the entire garment element shall be accomplished using advanced cleaning procedures Additional Requirements for Routine Cleaning of Helmet Elements If it is necessary to totally immerse the helmet, the impact cap shall be separated from the helmet shell. Each element component shall be washed and dried separately before reassembly /286

137 Solvents shall not be used to clean or decontaminate helmets or helmet components. The manufacturer shall be consulted if stronger cleaning agents are required Helmets shall not be machine dried using equipment that produces mechanical action from tumbling or agitation Additional Requirements for Routine Cleaning of Glove Elements. Glove elements shall not be machine dried using equipment that produces mechanical action from tumbling or agitation Additional Requirements for Routine Cleaning of Footwear Elements. Footwear elements shall not be machine dried using equipment that produces mechanical action from tumbling or agitation Additional Requirements for On Scene (Preliminary) Cleaning of Hood Interface Components. Following on scene cleaning of ensembles, hood interface components shall be subjected to advanced cleaning following each structural fire or emergency service use Additional Requirements for Routine CleaningOn Scene (Preliminary) Cleaning of Proximity Fire Fighting Ensembles and Ensemble Elements. Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall not be cleaned with a brush or any other abrasive cleaning devices Where routine cleaning fails to render the ensemble or ensemble element(s) sufficiently clean for service, the ensemble or ensemble element(s) shall receive advanced cleaning. Global FR 80 Supplemental Information File Name FR_63_7.2.docx FR 63_7.2_Annex_changes.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 12:56:07 EDT 2017 Committee Statement Committee Other proposed changes to NFPA 1851 have modified the hierarchy of cleaning as applied Statement: to soiled and contaminated ensemble elements. These changes reflect initial modification of the section to adopt this philosophy. The NFPA 1851 technical committee has determined that utility sink cleaning is no longer useful and that routine cleaning should instead reflect 133/286

138 Response Message: initial cleaning that is performed on scene or as soon as possible practical after the emergency event. Public Input No. 106 NFPA [New Section after 7.2.5] Public Input No. 211 NFPA [Section No. 7.2] Public Input No. 14 NFPA [Section No ] Public Input No. 66 NFPA [Section No ] Public Input No. 65 NFPA [Section No ] Public Input No. 64 NFPA [Section No ] Public Input No. 177 NFPA [Section No. A.7.2.1] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M /286

139 King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 135/286

140 First Revision No. 64 NFPA [ Sections 7.3, 7.4 ] 7.3 Advanced Cleaning and Decontamination Advanced cleaning shall be performed by the element manufacturer, a manufacturer trained organization manufacturer trained organization, a verified organization, or a verified ISP The member(s) of the organization who has received training in the advanced cleaning of the ensembles or ensemble elements shall be responsible for performing, managing, or coordinating advanced cleaning or the advanced cleaning process The organization, in conjunction with the ensemble or ensemble element manufacturer or verified ISP, and the organization shall determine the level of training required to perform advanced cleaning. The ensemble or ensemble element manufacturer or verified ISP shall provide written verification of training * Global FR 77 The training of the organization s personnel shall be performed by the element manufacturer or a verified ISP, who will provide written documentation of training If the organization is a verified organization, it shall be permitted to determine the level of training that is needed for carrying out the advanced cleaning * Ensemble and ensemble elements that are soiled or soiled and contaminated shall receive advanced cleaning prior to reuse Advanced cleaning shall be applied to the ensembles and ensemble elements that are soiled, that have been exposed to contamination involving products of combustion, or that have been exposed to blood or other body fluids Ensembles or ensemble elements that have been exposed to bulk chemicals, unusual biological contaminants, asbestos, or other substances of a highly hazardous or unusual nature shall be subjected to specialized cleaning as specified in Section Ensemble and ensemble elements that are issued and used shall receive advanced cleaning at the time of advanced inspection if not subjected to advanced cleaning in the preceding 12 6 months The training of the organization s personnel shall be performed by the element manufacturer or a verified ISP, who will provide written documentation of training If the organization is a verified organization, it shall be permitted to determine the level of training necessary to perform advanced cleaning without any further written verification /286

141 7.3.5 Organizations shall examine the manufacturer s label and user information for instructions on cleaning and drying that the manufacturer provided with the element. In the absence of manufacturer s instructions or manufacturer s approval of alternative procedures for the ensemble or ensemble element, the advanced cleaning and drying procedures provided in this section shall be used * Advanced Where the use of machine cleaning is specified, advanced cleaning of ensembles and ensemble elements shall be conducted by machine using a washer/extractor with the following characteristics unless specifically prohibited. : (1) The washer/extractor shall have a minimum load capacity of 13.6 kg (30 lbs) and a minimum volumetric capacity of 0.11 m 3 (4.0 ft 3 ). (2) The washer/extractor shall be programmable to permit multiple formulations for adjustments of detergent application, water temperature, water level, and cycle time. (3)* The washer/extractor shall not have a g force that exceeds 100 g or shall have the capability of drum revolutions per minute (RPM) adjustment such that the g force can be adjusted to not exceed 100 g for all washed ensembles and ensemble elements * Top loading washing machines with or without a center post agitator shall not be used for advanced cleaning of ensembles and ensemble elements or components * If a cleaning device other than a washer/extractor is utilized, the element manufacturer shall be contacted for instructions on how to best clean the element(s) using the respective cleaning device Detergents and other cleaning or pretreatment chemicals used in the advanced cleaning of the ensembles and ensemble elements shall be appropriate for the respective ensemble or ensemble element. (See A ) Chlorine bleach, chlorinated solvents, or active ingredient cleaning agents or solvents shall not be used without the ensemble or ensemble element manufacturer s approval. (See A ) * For advanced cleaning using a washer/extractor, a mild detergent with a ph range of not less than 6.0 ph and not greater than 10.5 ph as indicated on the product safety data sheet (SDS) or original product container shall be used Selected detergents and cleaning agents shall not be known to cause significant long term degradation of ensemble or ensemble element performance when applied at the expected cleaning frequency over the service life of the ensemble or ensemble element. (See A ) Where used for the sanitization or disinfection of protective ensembles or ensemble elements, advanced cleaning procedures shall employ only disinfectants or sanitizers that are registered with the U.S. Environmental Protection Agency Office of Chemical Safety and Pollution Prevention OCSPP : Disinfectants and Sanitizers for Use on Fabrics and Textiles Efficacy Data Recommendations, and have been properly validated as to the specification claims of disinfection and sanitization. Selected disinfectants and sanitizers shall not degrade the performance properties of protective ensemble elements /286

142 7.3.9 Universal procedures shall be applied in the washing of all contaminated ensembles or ensemble elements The Where machine washing with a washer/extractor is specified, the following procedures shall be used for machine washing : (1)* The machine washer/extractor shall not be overloaded or underloaded. (2)* Heavily soiled or spotted areas shall be pretreated. Chlorine bleach, chlorinated solvents, active ingredient cleaning agents, or solvents shall not be used without the ensemble or ensemble element manufacturer s approval. (3) All closures, including pocket closures, hooks and loops, snaps, zippers, and hooks and dees shall be fastened. (4)* Water temperature shall not exceed 40 C (105 F). * A mild detergent with a ph range of not less than 6.0 ph and not greater than 10.5 ph as indicated on the product MSDS or original product container shall be used. * Washing machines with the capability of drum RPM adjustment shall be adjusted so the g force does not exceed 100 g for all elements. (5)* Machine The washer/extractor manufacturer s instructions shall be followed for proper setting or program selection for the specific element being washed. (6) The element shall be inspected and rewashed if necessary. * Where the machine is also used to wash items other than protective ensemble elements, it shall be rinsed out by running the machine without a laundry load through a complete cycle with detergent and filled to the maximum level with water at a temperature of 49 C to 52 C (120 F to 125 F) * Ensembles and ensemble elements shall be dried in accordance with Section 7.4 using the procedures in through * The following procedures shall be used for air drying: (1)* Elements shall be placed in an area with good ventilation. (2)* Elements shall not be dried in direct sunlight. (3) The area used for drying shall not exceed 40 C (105 F) * The following procedures shall be used for machine drying: (1) The recommended capacity of the machine shall not be exceeded. (2) All closures, including pocket closures, hooks and loops, snaps, zippers, and hooks and dees shall be fastened. All hooks that are not part of a closure shall be covered with a piece of loop. (3)* A no heat or air dry option shall be permitted to be used, if available. (4)* In the absence of a no heat or air dry option, the basket temperature shall not exceed 40 C (105 F). (5)* The use of a heat cycle shall be discontinued prior to the removal of all moisture from the ensemble or ensemble elements. (6)* The remainder of the drying process shall be accomplished by a no heat machine setting or removal of the ensemble or ensemble elements from the machine dryer to air dry /286

143 Ensembles or ensemble elements that are not completely dry shall not be used for emergency services Additional Requirements for Advanced Cleaning of Garment Elements Garment elements shall be subjected to advanced cleaning using a washer/extractor with an appropriate formulation. A top loading washing machine or utility sink shall not be used for advanced cleaning Separate washer/extractor formulations shall be permitted for garments that are soiled, contaminated with products of combustion, or contaminated with blood and body fluids. [See A.7.3.9(5).] * Where the shells and liners of protective garment elements are separable, those components shall be cleaned and decontaminated only with similar components Separable liner systems shall be oriented such that the moisture barrier is on the inside for both liners in advanced cleaning Separate washer/extractor formulations shall be permitted for washing garment shells versus garment liners If the coat element has a drag rescue device (DRD) and the DRD is removable, the DRD shall be removed prior to the coat being laundered. If the DRD also requires cleaning, it shall be placed in a separate mesh bag for washing and drying Removable DRDs shall be placed in a separate mesh bag for advanced cleaning If the garment includes fall protection components, and the fall protection components are removable, the fall protection shall be removed prior to advanced cleaning If the fall protection also requires cleaning, it shall be cleaned separately according to the manufacturer s instructions * Where the shells and liners of protective garment elements are separable, those items shall be cleaned and decontaminated only with like items, other than as provided for in Separable liner systems shall be turned inside out so the moisture barrier is on the inside for both machine washing and machine drying Additional Requirements for Advanced Cleaning of Helmet Elements Detachable items components, such as ear covers, suspensions covers, and goggles shall be removed from the helmet and shall be washed and dried separately /286

144 * Detachable components that are textile based shall either be separately hand washed or washed in a washer/extractor with other components such as garments or hoods as specified in Helmets shall not be machine cleaned or dried using equipment that produces mechanical action by tumbling or agitation * Helmets shall be hand washed on both the interior and exterior surfaces in a utility sink using a soft bristle brush to reach between components and into difficult to access spaces. The helmet shall be thoroughly rinsed following washing Attached faceshields shall be hand washed with a soft cloth Goggles shall be separately hand washed after every fire or emergency scene use Additional Requirements for Advanced Cleaning of Glove Elements * Gloves shall not be machine dried using equipment that produces mechanical action by tumbling or agitation Unless otherwise specified, gloves shall be hand washed in a utility sink or other container of sufficient size using the following procedures: (1) The individual washing the gloves shall put on a pair of examination gloves and an apron. (2) The utility sink shall be filled with warm water at temperature no warmer than 40 C (105 C) and a mild detergent. (3) The individual shall then don the fire fighting gloves over the examination gloves and shall briskly rub the gloves together, ensuring the cleaning of all surfaces. (4) The individual shall then remove the fire fighting gloves and submerge the gloves in the wash water. (5) The interior and exterior of the gloves shall be thoroughly rinsed with clean water. (6) The excess water shall be squeezed out of the gloves and the gloves shall be placed on a drying rack. Wringing of the gloves shall not be permitted Additional Requirements for Advanced Cleaning of Footwear Elements * Footwear shall not be machine cleaned or dried using equipment that produces mechanical action by tumbling or agitation /286

145 Unless otherwise specified, footwear shall be hand washed in a utility sink or other container of sufficient size using the following procedures: (1) The individual washing the footwear shall put on a pair of examination gloves and an apron. (2) The utility sink shall be filled with warm water at a temperature no warmer than 40 C (105 C) and a mild detergent. (3) The individual shall first scrub the interior of the footwear with a soft bristle brush. (4) The individual shall then scrub the exterior of the footwear with a soft bristle brush, ensuring the cleaning of all exterior surfaces. (5) The interior and exterior of the footwear shall be thoroughly rinsed with clean water. (6) The footwear shall be suspended upside down to dry, with attention that water runoff does not create a slip hazard. (7) If specified by the manufacturer, a sealant, conditioning, or polishing shall be applied to leather footwear after the footwear has completely dried Additional Requirements for Advanced Cleaning of Hood Elements Hoods shall be subjected to advanced cleaning after every fire or emergency service use Hoods shall be permitted to be machine washed and machine dried with garment liners If hoods are hand washed in a utility sink or other suitable container, hoods shall not be wrung out to dry, but instead slightly squeezed to remove excess water after rinsing Hoods shall be permitted to be air dried or machine dried Special care shall be applied to the advanced cleaning of particulate blocking hoods. Advanced cleaning of particulate blocking hoods shall be in accordance with procedures provided by the manufacturer Additional Requirements for Advanced Cleaning of Proximity Fire Fighting Ensembles and Ensemble Elements Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall not be cleaned with a brush or other abrasive cleaning devices Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall not be machine washed or dried Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall be hand washed with a moist soft cloth or sponge Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall not be machine dried /286

146 Outer shell and other radiant reflective components of proximity fire fighting protective ensembles and ensemble elements shall be hung without any folding of the shell and air dried without any mechanical action Additional Requirements for Advanced Cleaning of Ensembles Certified to the Optional CBRN Liquid and Particulate Contamination Protection Requirements of NFPA The manufacturer shall be consulted to determine if any special handling procedures or the removal of interface components or other components must be undertaken prior to advanced cleaning. 7.4 Specialized Cleaning Organizations shall employ specialized cleaning where it is recognized the ensemble or ensemble elements cannot be adequately cleaned and decontaminated with advanced cleaning * Organizations shall designate exposure to any specific substances or contaminants that warrant specialized cleaning such as certain bulk chemicals, asbestos, or highly infectious, persistent microorganisms Organizations shall rely on expertise from hazardous materials teams, infection control specialists, verified independent service providers, or other individuals knowledgeable about the type of the contaminant and how it can be removed from protective clothing and equipment. This expertise shall be applied for determining whether the type of contamination can be effectively removed and the procedures to be used for the removal of the specific contaminant(s) In cases where a determination is made that the contaminant(s) cannot be sufficiently removed, the ensemble or ensemble elements shall be condemned and disposed of in accordance with local, state, and federal regulations for the handling and disposal of hazardous materials In cases where a determination is made that the contaminant(s) can be sufficiently removed, specific procedures shall be applied and a rationale provided for judging the efficacy of the specialized cleaning procedures that are used * Where risk is judged to exist for the reuse of ensembles or ensemble elements that have been exposed to bulk chemicals, infectious microorganisms, or other hazardous substances, the organization shall consider testing of sample ensembles or ensemble elements to determine whether any residual contamination remains after the applied specialized cleaning procedures. Any testing procedures that are used for assessing residual levels of contamination shall be specific to the contaminants of concern When specialized cleaning is applied for the cleaning of ensembles or ensemble elements involving highly hazardous contaminants, consideration should be given to the disposition of the effluent from the cleaning process and whether disposal into the local sewer system is acceptable according to local, state, and federal regulations. 7.4 Drying Procedures /286

147 7.4.1* Organizations shall examine the manufacturer s label and user information for instructions on drying procedures that the manufacturer provided with the ensemble or ensemble element. In the absence of manufacturer s instructions or manufacturer s approval of alternative procedures, the drying procedures provided in this section shall be used * The following procedures shall be used for air drying: * Elements shall be placed in an area with good ventilation. * Elements shall not be dried in direct sunlight * The following procedures shall be used for machine drying: The recommended capacity of the machine shall not be exceeded. All closures, including pocket closures, hooks and loops, snaps, zippers, and hooks and dees shall be fastened. * A no heat or air dry option shall be used, if available. * In the absence of a no heat or air dry option, the basket temperature shall not exceed 40 C (105 F). * The use of a heat cycle shall be discontinued prior to the removal of all moisture from the ensemble or ensemble elements. * The remainder of the drying process shall be accomplished by a no heat machine setting or removal of the ensemble or ensemble elements from the machine dryer to air dry. Supplemental Information File Name FR_64_7.3_7.4.docx FR 64_7.3_and_7.4_Annex_changes.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:07:04 EDT 2017 Committee Statement Committee A large number of proposed changes have been made to Section 7.3 on Advanced Statement: Cleaning to account for evolving industry knowledge and practices for the effective cleaning of turnout clothing. Many of these changes follow other modifications within Chapter 7 to address a new hierarchy of cleaning. Among the significant changes are the transition to solely using washer/extractors as the principal machine for washing garments and other elements. Additional details have been provided for the specific procedures related to advanced cleaning of individual elements. In addition, drying procedures have been incorporated into Section 7.3 and several parts of the section have been reorganized along with the respective annex sections /286

148 Response Message: Other significant changes incorporated via public inputs include transitioning to a minimum requirement, applying two advance cleanings per year regardless of clothing soiling and contamination levels, the provision of default wash formulations, and specialized handling of proximity firefighting outer shells and other radiant protective components. A new section has been added to address specialized cleaning had previously was not addressed within NFPA Public Input No. 162 NFPA [Section No. A ] Public Input No. 161 NFPA [Section No ] Public Input No. 212 NFPA [Global Input] Public Input No. 16 NFPA [New Section after 7.3.3] Public Input No. 156 NFPA [New Section after ] Public Input No. 25 NFPA [New Section after ] Public Input No. 24 NFPA [New Section after 7.3] Public Input No. 93 NFPA [Section No ] Public Input No. 155 NFPA [Section No ] Public Input No. 188 NFPA [Section No. A.7.3.7(2)] Public Input No. 186 NFPA [Section No. A.7.3.6] Public Input No. 107 NFPA [Section No ] Public Input No. 209 NFPA [Global Input] Public Input No. 166 NFPA [Section No ] Public Input No. 92 NFPA [Section No ] Public Input No. 158 NFPA [New Section after ] Public Input No. 163 NFPA [Section No. A ] Public Input No. 196 NFPA [New Section after ] Public Input No. 67 NFPA [New Section after 7.4.2] Public Input No. 183 NFPA [Section No. A.7.3.2] Public Input No. 160 NFPA [Section No ] Public Input No. 55 NFPA [Section No ] Public Input No. 167 NFPA [Section No ] Public Input No. 108 NFPA [Section No ] Public Input No. 169 NFPA [New Section after ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 144/286

149 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J /286

150 Affirmative with Comment Granger, Jr., Richard O. OK 146/286

151 First Revision No. 65 NFPA [ Section No ] Where moisture barrier tears, holes, or abrasions are being repaired, a single width of seam the repair tape shall be used and shall be required to extend at least 12.5 mm ( 1 2 in.) in all directions beyond the edge of the repaired damage. Where the moisture barrier has a hole or abrasion measuring more than 12.5 mm ( 1 2 in.) in diameter in any direction or a tear greater than 75 mm (3 in.) in length, a patch consisting of the same moisture barrier fabric shall be used for repair. Supplemental Information File Name FR_65_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:23:26 EDT 2017 Committee Statement Committee Statement: Response Message: This rewritten section allows the use of multiple widths and multiple pieces of tapes which have shown to be effective in the repair of moisture barriers. Public Input No. 30 NFPA [Section No ] Public Input No. 153 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned 147/286

152 Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 148/286

153 First Revision No. 66 NFPA [ Section No ] Visibility markings being replaced shall be completely removed so that no new visibility marking is sewn over an older sewn visibility marking. New visibility markings shall be permitted to be applied over older visibility markings by alternative methods where approved by the garment manufacturer. Supplemental Information File Name FR_66_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:29:22 EDT 2017 Committee Statement Committee Recently, new forms of NFPA compliant high visibility trim materials began to be available Statement: for use on firefighter garments. These new trims attach directly to the shell fabric without the use of thread or stitching, as has been the historic norm. This change allows for repair of these new, emerging technologies. Response Message: Public Input No. 27 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 30 Affirmative All 1 Affirmative with Comments 1 Negative with Comments 0 Abstention Not Returned Ott, Louis V /286

154 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK Negative with Comment 150/286

155 Reidy, Jim If we require damaged/worn sewn reflective to be completely removed before new reflective is sewn into its place then any damaged/worn reflective that needs to be replaced should be removed. After all the talk about stored energy, we should not be layering new reflective material on top of old. How many layers can be overlapped? 151/286

156 First Revision No. 67 NFPA [ Section No ] 8.4.4* Repairs to garment thermal liners shall be permitted provided there is no the repair does not result in any stitching through the moisture barrier. Supplemental Information File Name FR_67_8.4.4.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:32:30 EDT 2017 Committee Statement Committee The current text could be interpreted to mean that stitching through the moisture barrier Statement: occurred before the repair and was the determining factor. This edit makes the sentence clearer and leaves less room for misinterpretation. Response Message: Public Input No. 124 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 152/286

157 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 153/286

158 First Revision No. 68 NFPA [ Sections 8.8, 8.9 ] 8.8 Structural Fire Fighting Hood and Proximity Fire Fighting Helmet Overcover and Proximity Fire Fighting Shroud Repair. In addition to the requirements in Section 8.1, all repairs to hoods, helmet covers, and proximity shrouds shall be performed in accordance with the element manufacturers instructions. Repairs of these interface components containing a particulate blocking layer shall not be undertaken unless authorized by the manufacturer. 8.9 Additional Requirements for Structural Fire Fighting Ensembles and Proximity Fire Fighting Ensembles with Optional CBRN Liquid and Particulate Contamination Protection. In addition to the requirements in Section 8.1, all repairs to ensembles with optional CBRN liquid and particulate contamination protection shall be referred to the ensemble manufacturer. Supplemental Information File Name FR_68_8.8_8.9.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:35:38 EDT 2017 Committee Statement Committee This is to provide guidance when dealing with interface components that contain a Statement: particulate blocking layer. Also, continuing to remove the CBRN requirements from NFPA Response Message: Public Input No. 56 NFPA [Section No. 8.9] Public Input No. 210 NFPA [Section No. 8.8] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 154/286

159 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J /286

160 Affirmative with Comment Granger, Jr., Richard O. OK 156/286

161 First Revision No. 69 NFPA [ Section No ] 9.1.1* Ensembles or ensemble elements not in use shall not be stored in direct sunlight or exposed to direct sunlight while not being worn exposed to lighting that emits UV rays, including, but not limited to, fluorescent lighting, direct sunlight, and indirect sunlight. Supplemental Information File Name FR_69_9.1.1.docx FR 69_A.9.1.1_changes.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:44:49 EDT 2017 Committee Statement Committee The fluorescent lighting storage restriction should be a mandatory requirement versus Statement: simply mentioned in the annex. Damage to materials is occurring under this lighting type and should be restricted. Additional clarification is being provided to the annex on the types of light sources that should be avoided including all light sources that emit UV rays. Response Message: Public Input No. 94 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 157/286

162 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O /286

163 OK 159/286

164 First Revision No. 70 NFPA [ Section No ] 9.1.6* Soiled Issued ensembles and ensemble elements shall not be stored allowed in living quarters or with personal belongings or taken or transported in the passenger compartment of personal vehicles.. Contaminated or soiled clothing shall not be transported in the cab of fire department apparatus when not being worn for operational duties. Where ensembles or ensemble elements must be stored or transported in such environments in personal vehicles, the ensembles or ensemble element(s) shall be placed in a protective case or bag to prevent cross contamination cross contamination, and shall be removed from such environments as soon as possible. Supplemental Information File Name FR_70_9.1.6.docx FR 70_A.9.1.6_changes.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:49:51 EDT 2017 Committee Statement Committee Additional emphasis is need to indicated that the transport of contaminated or soil gear in Statement: vehicles, including apparatus, created a health risk and contributed to the spread of contamination. The annex language has been expanded to clarify this risk. Response Message: Public Input No. 38 NFPA [Global Input] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 30 Affirmative All 0 Affirmative with Comments 2 Negative with Comments 0 Abstention 160/286

165 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Negative with Comment Durby, Tim 161/286

166 I agree with Rich. Taking PPE out of cab while on duty is not realistic. Granger, Jr., Richard O. I disagree with the removal of gear from the cab. Gear used on a scene may be needed when you receive an additional call while in route back to quarters. Departments do not have the resources to put companies out of service nor should we set them up to be ineffective when returning from duty. This happens rarely and the minimal exposure is out weighed by our duty to act /286

167 First Revision No. 71 NFPA [ New Section after ] Eye and face protection shall be readily accessible to the user and, when not in use, shall be stored in such a manner so as to prevent at least the following: (1) Thermal damage (2) Mechanical damage (3) Hazardous materials contamination Supplemental Information File Name FR_71_9.1.9_new.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 13:57:54 EDT 2017 Committee Statement Committee The current eye and face protective components are inconsistent with the level of Statement: protection provided and their application subjects them to unnecessary damage (thermal and mechanical) as well as hazardous particulate contamination. Users must be instructed on the proper way to clean and decontaminate the eye and face protection without causing damage to these components. Response Message: Public Input No. 98 NFPA [New Section after 9.1.9] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention 163/286

168 Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O /286

169 OK 165/286

170 First Revision No. 72 NFPA [ Section No ] * In all cases, the radiant reflective outer shell of the garment element shall be replaced at a maximum of no more than 5 years from the date the ensembles or ensemble elements were manufactured. Supplemental Information File Name FR_72_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 17:22:29 EDT 2017 Committee Statement Committee Statement: Response Message: The Technical Committee makes this section clearer and consistent with section Public Input No. 125 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 166/286

171 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 167/286

172 First Revision No. 74 NFPA [ Section No ] * Structural fire fighting ensembles and ensemble elements and proximity fire fighting ensembles and ensemble elements that are worn or damaged to the extent that the organization deems it not possible or cost effective to repair them shall be retired in accordance with Supplemental Information File Name FR_74_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 17:27:41 EDT 2017 Committee Statement Committee Statement: Response Message: The section is easier to read without them and removing them does not change the meaning of the section. Public Input No. 126 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 168/286

173 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 169/286

174 First Revision No. 75 NFPA [ Section No ] Retired structural fire fighting ensembles and ensemble elements and proximity fire fighting ensembles and ensemble elements as determined in to be no longer of use in accordance with shall be permitted to be used as follows: (1) For training that does not involve live fire, provided the ensembles and ensemble elements are appropriately marked as being for non live fire training only (2) As determined by the organization Supplemental Information File Name FR_75_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 17:30:55 EDT 2017 Committee Statement Committee Statement: Makes the section more understandable. Response Message: Public Input No. 127 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D /286

175 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 171/286

176 First Revision No. 88 NFPA [ Section No ] Verification of the organization or ISP shall include advanced inspection, advanced cleaning, and advanced repairs of garment elements only. Verification of the organization or ISP shall not apply to helmet elements, glove elements, footwear elements, hood elements, or optional CBRN liquid and particulate contamination protective ensembles. Supplemental Information File Name FR_88_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 22:59:43 EDT 2017 Committee Statement Committee This section should be modified as the CBRN option has been removed from NFPA 1971 Statement: and there are no certified ensembles that meet these optional requirements. The proposed changes address the new optional category of liquid and particulate contamination protective ensembles. Response Message: Public Input No. 57 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V /286

177 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 173/286

178 First Revision No. 89 NFPA [ Section No ] An organization or ISP shall be permitted to be verified for advanced cleaning and advanced inspection only. An ISP shall be verified for advanced cleaning, advanced inspection, and repairs, but shall not be permitted to be verified for advanced cleaning and advanced inspection only. Supplemental Information File Name FR_89_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:08:22 EDT 2017 Committee Statement Committee By requiring ISP s to offer all three services, this change will eliminate any possible Statement: confusion over which service the ISP has been verified to provide. The Technical Committee concluded that ISP s must be verified for all three services. Response Message: Public Input No. 68 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 29 Affirmative All 3 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D /286

179 Sisson, Kelly Affirmative All Berger, George E. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Allen, Jason L. I think by making this change to the wording we will create significant gaps geographically in available services that can clean and inspect. The better solution to clarify this issue would be through better mandatory language on verification documents which could specifically show what a location is and isnt approved for. Corrado, Steven D. This revision will create a gap in available offerings beneficial to the fire service. Clarification to the documentation provided to verified ISPs by the certification organizations may be a better solution to 175/286

180 any confusion in the industry. By providing a clear scope of what the actual verification entails on certificates and supporting documentation, misrepresentation of verified services can be eliminated without removing eligible ISPs for cleaning and repair only. Granger, Jr., Richard O. OK 176/286

181 First Revision No. 90 NFPA [ Section No ] The verified organization or ISP shall be listed. The listing shall contain advanced cleaning and advanced inspection; or advanced cleaning, advanced inspection, and/or the repair categories that the organization or the ISP is verified to conduct. Repair categories shall be garment outer shell repairs, garment moisture barrier repairs, and garment thermal barrier repairs. Supplemental Information File Name FR_90_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:13:20 EDT 2017 Committee Statement Committee Statement: Response Message: This removes the term "and/or" and clarifies the options for listing the ISPs, making consistent with through Public Input No. 31 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 177/286

182 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 178/286

183 First Revision No. 91 NFPA [ Section No ] Where the certification listing includes the moisture barrier repair category, the listing shall include the moisture barrier manufacturer and trade name designation, and the repair tape manufacturer and trade name or part number. Supplemental Information File Name FR_91_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:19:05 EDT 2017 Committee Statement Committee Statement: Response Message: Multiple tape materials may be used by the industry for the same moisture barrier. This clarifies the listing. Public Input No. 105 NFPA [Section No ] Public Input No. 32 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D /286

184 Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 180/286

185 First Revision No. 92 NFPA [ Section No ] All verification of the organization or ISP shall be performed by a certification organization that meets at least the requirements specified in Section 11.2 and that is accredited for personal protective equipment (PPE) in accordance with ISO Guide 65, General requirements for bodies operating product certification systems ISO/IEC 17065, Conformity assessment Requirements for bodies certifying products, processes and services. The accreditation shall be issued by an accreditation body operating in accordance with ISO 17011, Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies. Supplemental Information File Name FR_92_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:24:00 EDT 2017 Committee Statement Committee Statement: Response Message: ISO Guide 65 has been replaced by ISO/IEC therefore the reference needs to be updated in Public Input No. 100 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned 181/286

186 Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 182/286

187 First Revision No. 93 NFPA [ Sections , ] The certification organization shall not issue any new verifications to the edition of NFPA 1851 on or after the NFPA effective date for the edition, which is August 21, Organizations or ISPs verified to the edition of NFPA 1851 shall undergo verification to the edition of NFPA 1851 within 6 months of the NFPA effective date for the edition, which is August 21, Supplemental Information File Name FR_93_11.1.4_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:39:06 EDT 2017 Committee Statement Committee Statement: Updating references and dates. Response Message: Public Input No. 129 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V /286

188 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 184/286

189 First Revision No. 94 NFPA [ Section No ] The certification organization shall be accredited for personal protective equipment PPE in accordance with ISO Guide 65, General requirements for bodies operating product certification systems ISO/IEC 17065, Conformity assessment Requirements for bodies certifying products, processes and services. The accreditation shall be issued by an accreditation body operating in accordance with ISO 17011, Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies. Supplemental Information File Name FR_94_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:45:38 EDT 2017 Committee Statement Committee Statement: Response Message: ISO Guide 65 has been replaced by ISO/IEC therefore the reference needs to be updated in Public Input No. 101 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V /286

190 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 186/286

191 First Revision No. 95 NFPA [ Section No ] The certification organization shall be permitted to conduct additional specific testing to verify continued compliance. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 23:50:30 EDT 2017 Committee Statement Committee Statement: Response Message: This clarifies that this paragraph refers to testing that is above and beyond the testing requirements for re verification. Public Input No. 34 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D /286

192 Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 188/286

193 First Revision No. 79 NFPA [ Section No ] For verification of an organization s or an ISP s advanced cleaning services, the certification organization shall evaluate the organization s or ISP s procedures in accordance with Section 7.3 of this standard. For verification of an ISP s advanced cleaning services, the certification organization shall evaluate the ISP s procedures in accordance with Section 7.3 of this standard and evaluate the effectiveness of its cleaning processes against the requirements specified in and When tested for removal of selected products of combustion as specified in Section 12.7, the ISP cleaning process shall provide for a 90 percent or greater decontamination efficiency for each of the specified surrogate contaminants When tested for the neutralization and sanitization of biological contaminants as specified in Section 12.8, the ISP cleaning process shall provide for at least log4 reduction of incident challenge microorganisms. Supplemental Information File Name FR_79_ docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 18:17:52 EDT 2017 Committee Statement Committee An overwhelming amount of attention is being placed within the fire service for determining Statement: how effective cleaning is a removing contaminants from firefighter exposure during various emergency incidents, particularly as related to exposure to persistent chemical and carcinogenic contaminants. Research being conducted by the Fire Protection Research Foundation as partner organizations including the National Institute for Occupational Safety and Health (NIOSH), Intertek Testing Services (ITS), and International Personnel Protection, Inc. is being positioned to provide substantiation for any recommended procedures for cleaning validation as well as answer the question of how clean is clean? Response Message: Public Input No. 213 NFPA [Global Input] Ballot Results 189/286

194 This item has passed ballot 35 Eligible Voters 3 Not Returned 29 Affirmative All 3 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard 190/286

195 Winer, Harry P. Woods, Patrick J. Affirmative with Comment Allen, Jason L. I think we need to somehow differentiate that an organizations approval for advanced cleaning is not the same as an ISPs. Or create a specific option of Advanced Cleaning Decontamination that is an allowed additional approval for either ISPs or Organizations Granger, Jr., Richard O. OK Stull, Jeffrey O. Significant progress have been made with respect to further defining and validating the proposed cleaning effectiveness measurements techniques /286

196 First Revision No. 78 NFPA [ Section No ] /286

197 For verification of an organization s or an ISP s repair services, the following series of tests shall be required for each repair category for which the organization or the ISP is verified. Testing shall be conducted using new materials as outlined in Table (a) through Table (c). Initial samples submitted by the organization or ISP for verification shall be permitted to be prepared by that organization or ISP. Table (a) Outer Shell Repairs Who Makes Repair Organization ISP Sample Material 5 ft felled seam Outer shell material(s) utilized by the organization 5 ft overedge seam Small tear patch Patched tear made from the outer shell material utilized by the organization 5 ft felled seam 7.5 osy Nomex IIIa plain weave fabric 5 ft overedge seam Small tear patch Patched tear made from 7.5 osy Nomex IIIa plain weave fabric Test or Evaluation NFPA NFPA NFPA NFPA Table (b) Thermal Liner Repairs Who Makes Repair Organization ISP Sample 5 ft felled seam 5 ft overedge seam Small tear patch 5 ft felled seam 5 ft overedge seam Small tear patch Material Thermal liner material(s) utilized by the organization Patched tear made from the thermal liner material utilized by the organization Blended filament/spun face cloth quilted to two layers of E89 Patched tear made from blended filament/spun face cloth quilted to two layers of E89 Test or Evaluation NFPA NFPA NFPA NFPA Table (c) Moisture Barrier Repairs Who Makes Repair Sample Material Test or Evaluation Organization 5 ft seam Hole patch Moisture barrier material(s) utilized by the organization Patched hole made from the moisture barrier material(s) utilized by the organization NFPA NFPA and NFPA in the as received condition 193/286

198 Who Makes Repair ISP Sample Material Test or Evaluation Pinhole Repair Tear patch 5 ft seam Hole patch Pinhole Repair Tear patch Pinhole repair made from the moisture barrier material(s) utilized by the organization Patched tear made from the moisture barrier material(s) utilized by the organization All moisture barrier materials repaired by the ISP Patched hole made from the moisture barrier materials repaired by the ISP Pinhole repair made from the moisture barrier material(s) utilized by the ISP Patched hole made from the moisture barrier materials repaired by the ISP NFPA and NFPA 1851 Section 12.3 in as received and after preconditioning in NFPA NFPA and NFPA in the as received condition NFPA 1851 Section 12.3 in as received and after preconditioning in NFPA NFPA NFPA and NFPA in the as received condition NFPA and NFPA 1851 Section 12.3 in as received and after preconditioning in NFPA NFPA and NFPA in the as received condition and NFPA 1851 Section 12.3 in as received and after preconditioning in NFPA For repairs to tears in the outer shell, moisture barrier, and thermal barrier, the certification organization shall create inspect the tear in the material(s) to be repaired in accordance with Figure and shall witness the repair of the samples to be tested. Figure Tear Repairs /286

199 For moisture barrier hole pinhole repairs, the certification organization shall create inspect the hole pinholes in the material(s) to be repaired in accordance with Figure and shall witness the repair of the samples to be tested. The pinholes shall be created in the material(s) by using a size 8 gauge sewing needle to completely puncture the moisture barrier five times in a 25 mm (1 in.) square located in the center of a 305 mm 305 mm (12 in. 12 in.) sample. The 1 in. square shall be clearly marked to identify the damaged area. Figure Hole Repairs. DELETED Sample seams shall be prepared and submitted to the certification organization for verification testing by an NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, certified manufacturer, verified organization, or verified ISP. Initial sample seams submitted for verification by a certified manufacturer, verified organization, or verified ISP shall be prepared by the organization or ISP being verified for repairs Where a verified organization or verified ISP performs repairs for more than one garment manufacturer, then only one set of seam samples shall be required for verification testing For moisture barrier seam repairs, the certification organization or ISP shall damage the sample seams by cutting multiple stitches and the seam tape to a distance of 75 mm (3 in.) mm/ 0.00 mm (+ 1 2 in./ 0 in.). The certification organization shall inspect the damaged seams and witness the repair of the samples to be tested For outer shell and thermal barrier seam repairs, the certification organization or ISP shall damage the sample seams by cutting multiple stitches to a distance of 75 mm (3 in.) mm/ 0.00 mm (+ 1 2 in./ 0 in.). The certification organization shall inspect the damaged seams and witness the repair of the samples to be tested The certification organization shall not allow test specimens samples that have been conditioned and tested for one method to be reconditioned and tested for another test method unless specifically permitted in the test method. Supplemental Information File Name FR_78_ docx Description Approved For staff use 195/286

200 Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 17:59:53 EDT 2017 Committee Statement Committee Statement: Response Message: The committee has revised Section 11.3 to incorporate several revisions. These changes include: Provision for the ISP or the Certification Organization to be able to damage the sample that is to be repaired prior to testing. This will allow for flexibility in getting the samples damaged prior to repair and testing. In either case, the Certification Organization will still inspect the damaged sample prior to any repairs being made in order to ensure damage was performed correctly. Seam samples submitted for testing will no longer be allowed to be constructed by a garment manufacturer. The seam samples submitted for damage will be required to be constructed by the ISP or the organization seeking verification. Currently it has been the practice of some verified organizations and/or ISP s to purchase pre made seam kits and submit those as if they are an original submittal of verification samples. The ability to create seams required for submittal for verification should be considered as valuable as performing the required repairs. ISP s, even though considered repair facilities many times perform major repairs larger than what would be considered small patches. The ability to purchase pre made seam kits does not provide confidence that the ISP or verified organization has the skill, knowledge or ability to perform to the scope which is portrayed not only to the industry but the fire service. Based on the types of repairs typically made by ISP s to moisture barriers, the moisture barrier hole repair is being replaced by a pinhole repair. Since pinholes are a common type of moisture barrier repair, this repair type should be verified instead of the hole repair which is not a common repair. The following additional editorial changes were also made: In Table Evaluation was also added to Test to better reflect what is conducted. In The word garment was added to clarify that this relates to the garment manufacturer and not fabric manufacturer. In The term specimens was changed to samples for consistency. Public Input No. 185 NFPA [Section No ] Public Input No. 130 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 36 NFPA [Sections , ] Public Input No. 35 NFPA [Sections , ] Public Input No. 187 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 147 NFPA [New Section after ] Public Input No. 146 NFPA [Section No ] 196/286

201 Public Input No. 146 NFPA [Section No ] Public Input No. 184 NFPA [Sections , ] Public Input No. 33 NFPA [Section No ] Public Input No. 37 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 104 NFPA [Section No ] Public Input No. 182 NFPA [Section No [Excluding any Sub Sections]] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F /286

202 Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 198/286

203 First Revision No. 54 NFPA [ Section No ] 12.1 Light Evaluation of Liners * Application. This evaluation method shall apply to liner composites found in structural and proximity fire fighting protective garment elements that are in service Evaluation Areas At a minimum, the front and back body panels of each protective garment element shall be evaluated Specific areas of the body panels that shall be evaluated include the upper back, shoulders, underarms, sleeves, waist area, and crotch area Liner evaluation areas shall also be any areas of the garment where damage or loss of thermal protection is detected or expected Evaluation Apparatus. The apparatus used to perform the light evaluation shall have the following characteristics: The apparatus shall consist of a light source that provides enough light to show the changes in density of the liner materials when viewed. The light source shall not produce enough heat to damage the liner composite. The light source shall be configured to prevent the bulbs from directly contacting the liner composite. The light source shall be appropriately sized to fit into the sleeves of the liner Procedure The evaluation procedure shall be performed at room temperature The evaluation shall be conducted using the following procedure: If possible, separate the liner from the outer shell. Orient the liner so that the thermal barrier is on the outside. Position the light source near the moisture barrier so that the light passes through the moisture barrier and then through the thermal barrier. Evaluate the liner by examining the amount of light coming through the thermal liner Results Results shall be determined by evaluating areas where the light is brighter through some areas than others /286

204 Brighter areas could be an indication of insulating material shifting or migrating, resulting in a thin or bare spot To further evaluate a suspected area of shifting or migration, a complete liner inspection shall be performed. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 15:04:15 EDT 2017 Committee Statement Committee The recommendation of the public input is to remove the Light Test from the standard. The Statement: Light Test was originally included in the Standard to provide an easy method of evaluating the thermal barrier without opening the liner assembly. At the time, the rationale was sound. Now, however, after several years of experience with NFPA 1851, we have learned the Light Test is neither easy to conduct or as effective as opening the liner up and visually inspecting all layers for possible issues. The inclusion of this test in the Standard, along with the Complete Liner Inspection, also adds confusion to the inspection process. The Complete Liner Inspection is clearly the more effective method for evaluating the thermal barrier. It is also relatively easy and quick to perform. Since the performance of the thermal barrier is critical to the performance of the garment, it is appropriate for the Complete Liner Inspection to become a required part of the Advanced Inspection. This will both improve the Advanced Inspection and simplify the inspection criteria. Response Message: Public Input No. 74 NFPA [Section No. 12.1] Public Input No. 189 NFPA [Section No. 12.1] Public Input No. 203 NFPA [Section No. 12.1] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V /286

205 Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 201/286

206 First Revision No. 81 NFPA [ New Section after 12.2 ] 12.5 Smoke Evaluation of Hood Particulate Blocking Layers Application. This evaluation method shall apply to particulate blocking protective hood interface components that are in service Evaluation Areas. All portions of the hood interface component that contain a particulate blocking layer, including seams, shall be evaluated Evaluation Apparatus. An apparatus shall be used that consists of a perforated headform and half torso form along with a source for a theatrical smoke generator with a tube that connects the theatrical smoke source to the headform Procedure The evaluation procedure shall be conducted indoors in an area that is free from air currents The evaluation shall be conducted using the following procedure: (1) Don the hood on the headform. (2) Turn on the smoke generator and pump smoke through the tube into the headform and torso form. (3) Observe the headform for any smoke coming out of the headform Results. Results shall be determined by recording observations of smoke coming from the headform Interpretation. Any observed smoke coming out of the headform shall be considered a possible indication of a defect or other damage that compromises the hood s performance. Supplemental Information File Name FR_81_12.5.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 21:46:45 EDT /286

207 Committee Statement Committee Organizations and independent service providers need a means for assessing the integrity Statement: of the particulate blocking layer in particulate blocking hoods during advanced inspections. Five specific methods are proposed to determine the integrity based on use a lighted headform, a powder based technique, a fluorescent aerosol spray, by the measurement of air permeability, and the use of theatrical smoke through a perforated head and torso form. The committee is in the process of further investigating the utility and reliability of each testing approach. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L /286

208 Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 204/286

209 First Revision No. 82 NFPA [ New Section after 12.2 ] 12.4 Air Permeability Evaluation of Hood Particulate Blocking Layers Application. This evaluation method shall apply to particulate blocking protective hood interface components that are in service Evaluation Areas. All portions of the hood interface component that contain a particulate blocking layer, including seams, shall be evaluated Evaluation Apparatus. A Frazier air permeation test apparatus conforming to ASTM D737, Standard Test Method for Air Permeability of Textile Fabrics, shall be used. A test apparatus shall be selected that has the test head and clamping system on an arm that allows positioning of different areas of the sample in the test apparatus Procedure. Each area of the hood sample shall be tested by positioning the respective hood area into the hood and measuring the air permeability in accordance with ASTM D737, Standard Test Method for Air Permeability of Textile Fabrics Results. The air permeability shall be reported for each tested area of the hood Interpretation. Any hood area with an air permeability that is greater than 15.3 m 3 /min/m 2 (50 ft 3 /min/ft 2 ) shall be considered a possible indication of a defect or other damage that compromises the hood s performance. Supplemental Information File Name FR_82_12.4.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 21:50:33 EDT 2017 Committee Statement Committee Organizations and independent service providers need a means for assessing the integrity Statement: of the particulate blocking layer in particulate blocking hoods during advanced inspections. Five specific methods are proposed to determine the integrity based on use a lighted 205/286

210 Response Message: Ballot Results headform, a powder based technique, a fluorescent aerosol spray, by the measurement of air permeability, and the use of theatrical smoke through a perforated head and torso form. The committee is in the process of further investigating the utility and reliability of each testing approach. This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene 206/286

211 Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 207/286

212 First Revision No. 83 NFPA [ New Section after 12.2 ] 12.3 Fluorescent Spray Evaluation of Hood Particulate Blocking Layers Application. This evaluation method shall apply to particulate blocking protective hood interface components that are in service Evaluation Areas. All portions of the hood interface component that contain a particulate blocking layer, including seams, shall be evaluated Evaluation Supplies. For this evaluation, the evaluation apparatus shall consist of the following: (1) A fluorescent liquid with a spray bottle or other suitable device to create a fine mist or aerosol spray (2) Black construction paper (3) A cardboard form that is used for mounting the hood interface component in a flat position (4) A black UV light such as a flashlight Procedure The evaluation procedure shall be conducted indoors in an area that can be darkened so as to provide for optimum use of a fluorescent black (UV) light The following procedure shall be applied in this test: (1) Cut out a piece of cardboard that allows the hood to lay flat but does not overstretch the hood material. (2) Place a similarly shaped piece of black construction paper over the cardboard and use paper clips to secure the paper over the cardboard. (3) Position the sample hood over the cardboard and black construction paper. (4) Spray a mist onto the surface of the hood taking care not to saturate any one area with liquid. (5) After applying the mist, carefully remove the hood from the cardboard. (6) Examine the black paper with the fluorescent black (UV) light in a darkened area to determine if any of the aerosol penetrated the test areas of the hood. (7) Apply the technique in steps 1 through 6 to other areas of the hood that contain a particulate blocking layer Results. Results shall be determined by identifying any areas of the fluorescent liquid that are visible on the black construction paper when using the fluorescent black (UV) light Interpretation. Areas of fluorescent liquid appearing on the black paper shall be considered a possible indication of a defect in the particulate blocking layer or other damage that compromises the hood s performance /286

213 Supplemental Information File Name FR_83_12.3.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 21:53:30 EDT 2017 Committee Statement Committee Organizations and independent service providers need a means for assessing the integrity Statement: of the particulate blocking layer in particulate blocking hoods during advanced inspections. Five specific methods are proposed to determine the integrity based on use a lighted headform, a powder based technique, a fluorescent aerosol spray, by the measurement of air permeability, and the use of theatrical smoke through a perforated head and torso form. The committee is in the process of further investigating the utility and reliability of each testing approach. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F /286

214 Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 210/286

215 First Revision No. 84 NFPA [ New Section after 12.2 ] 12.2 Powder Penetration Evaluation of Hood Particulate Blocking Layers Application. This evaluation method shall apply to particulate blocking protective hood interface components that are in service Evaluation Areas. All portions of the hood interface component that contain a particulate blocking layer, including seams, shall be evaluated Evaluation Supplies. For this evaluation, the evaluation apparatus shall consist of the following: (1) A test white powder with a particle size distribution that includes at least 50 percent of the total particles that are less than 10 µm in diameter. A powder that contains a fluorescent agent shall be permitted to be used. (2) A measuring spoon that can dispense 1 4 tsp. of powder. (3) A brush to spread the powder over the test surface. (4) Black construction paper. (5) A cardboard form that is used for mounting the hood interface component in a flat position. (6) A black UV light such as a flashlight Procedure The evaluation procedure shall be conducted indoors in an area that is free from air currents The following procedure shall be applied in this test: (1) Cut out a piece of cardboard that allows the hood to lay flat but does not overstretch the hood material. (2) Place a similarly shaped piece of black construction paper over the cardboard and use paper clips to secure the paper over the cardboard. (3) Position the sample hood over the cardboard and black construction paper. (4) Measure out 1 4 tsp. of the selected powder on the area of the hood to be evaluated and use the brush to spread and push down the powder on top of the areas to be evaluated. (5) Following the application of the powder, invert the hood mounted on the paper covered cardboard holder and carefully remove the hood from the holder. (6) If an ordinary white powder is used, examine the black paper in a well lit area to determine if any powder penetrated the test areas of the hood. (7) If a fluorescent powder is used, examine the black paper in a darkened area to determine if any of the powder penetrated the test areas of the hood. (8) Apply the technique in steps 1 through 7 to other areas of the hood that contain a particulate blocking layer /286

216 Results. Results shall be determined by identifying any areas of the hood powder that are visible on the black construction paper Interpretation. Areas of visible powder shall be considered a possible indication of a defect in the particulate blocking layer or other damage that compromises the hood s performance. Supplemental Information File Name FR_84_12.2.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 21:56:28 EDT 2017 Committee Statement Committee Organizations and independent service providers need a means for assessing the integrity Statement: of the particulate blocking layer in particulate blocking hoods during advanced inspections. Five specific methods are proposed to determine the integrity based on use a lighted headform, a powder based technique, a fluorescent aerosol spray, by the measurement of air permeability, and the use of theatrical smoke through a perforated head and torso form. The committee is in the process of further investigating the utility and reliability of each testing approach. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly 212/286

217 Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 213/286

218 First Revision No. 85 NFPA [ New Section after 12.2 ] 12.1 Light Evaluation of Hood Particulate Blocking Layers Application. This evaluation method shall apply to particulate blocking protective hood interface components that are in service Evaluation Areas. All portions of the hood interface component that contain a particulate blocking layer, including seams, shall be evaluated Evaluation Apparatus. An apparatus shall be used that consists of a glass headform combined with a bright enough light source to show the changes in density of the liner materials when viewed. The light source shall be mounted at the center of the headform interior and have a means for turning the light on and off and for replacing it Procedure The evaluation procedure shall be conducted indoors in an area that can be darkened to provide for optimum viewing of potential damage to the particulate blocking layer of the hood interface component The evaluation shall be conducted using the following procedure: (1) Don the hood on the headform. (2) Turn on the light inside the headform. (3) Evaluate any area of the hood that has the particulate blocking layer in place including seams Results. Results shall be determined by evaluating areas where the light is brighter through some areas than others Interpretation. Brighter areas shall be considered a possible indication of a defect or other damage that compromises the hood s performance. Supplemental Information File Name FR_85_12.1.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: 214/286

219 State: Zip: Submittal Date: Sat Apr 15 21:58:59 EDT 2017 Committee Statement Committee Organizations and independent service providers need a means for assessing the integrity Statement: of the particulate blocking layer in particulate blocking hoods during advanced inspections. Five specific methods are proposed to determine the integrity based on use a lighted headform, a powder based technique, a fluorescent aerosol spray, by the measurement of air permeability, and the use of theatrical smoke through a perforated head and torso form. The committee is in the process of further investigating the utility and reliability of each testing approach. Response Message: Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl 215/286

220 Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 216/286

221 First Revision No. 56 NFPA [ Section No ] 12.2 Leakage Evaluation * Application. This evaluation method shall apply to moisture and thermal barrier liners found in structural or proximity fire fighting protective garment elements that are in service Evaluation Areas At a minimum, the front and back body panels of each protective garment element shall be evaluated using three different moisture barrier material areas and three different moisture barrier areas with a seam Liner evaluation areas shall be from high abrasion areas of the garment elements, including, but not limited to: Broadest part of the shoulders Back waist area of the coat Knees Crotch area Seat area In addition to the areas listed in where potential damage to the garment outer shell or thermal barrier has been detected, the evaluation shall be conducted on the corresponding area of the moisture barrier. Where potential damage to the garment moisture barrier has been detected, the evaluation shall also be conducted on that area The liner composite shall be positioned in the evaluation apparatus so that the moisture barrier is oriented upward and is contacted with the liquid exposure in the evaluation apparatus Moisture barrier material areas with seams shall be positioned on the evaluation apparatus so that the seam divides the specimen into two equal halves Evaluation Apparatus * An alcohol tap water mixture shall be made by combining 1 part rubbing alcohol (70 percent isopropanol alcohol) with 6 parts tap water A 5 gal bucket or similar container shall be used to support the liner during evaluation Procedure The evaluation procedure shall be performed at room temperature /286

222 The evaluation shall be conducted using the following procedure: If possible, separate the liner from the outer shell. Orient the liner so that the moisture barrier is on the outside. Position the dry liner over the bucket with the thermal barrier facing down and the moisture barrier side facing up. Cup the liner area that is being evaluated, so that it is lower than the surrounding liner. Pour 1 cup of the alcohol tap water mixture specified in onto the moisture barrier in the cupped area of the liner Results The liner shall be visually inspected for leakage on the thermal barrier side after 3 minutes If any liquid passes through the moisture barrier and wets the thermal barrier, the liner shall be removed from service and repaired or replaced After the evaluation procedure has been performed, the liner shall be cleaned and allowed to completely dry to remove all traces of the alcohol tap water mixture. Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Apr 14 15:41:03 EDT 2017 Committee Statement Committee The Puddle Test was originally included in the Standard to provide an easy method of Statement: evaluating of the moisture barrier without opening the liner assembly or having the ability to perform the hydrostatic test. At the time, the rationale was sound. Now, however, after several years of experience with NFPA1851, we have learned the Puddle Test is neither easy to conduct or as effective as opening the liner up and performing the hydrostatic test. The inclusion of this test in the Standard, along with the Complete Liner Inspection, also adds confusion to the inspection process and is a very time consuming task and further more is not used commonly in the industry. The Hydrostatic Test as the recommended procedure to evaluate leakage of the moisture barrier while performing the Complete Liner Inspection is clearly the more effective method for evaluating the moisture barrier layer. It is also relatively easy and quick to perform. Since the performance of the moisture barrier is critical to the performance of the garment, it is appropriate for the hydrostatic test to be the recommended leakage evaluation within the Complete Liner Inspection. This will both improve the Advanced Inspection and simplify the inspection criteria. Public Input No. 78 NFPA [Section No ] Public Input No. 71 NFPA [Section No ] Public Input No. 70 NFPA [Section No [Excluding any Sub Sections]] Public Input No. 75 NFPA [Section No ] 218/286

223 Public Input No. 75 NFPA [Section No ] Public Input No. 77 NFPA [Section No ] Public Input No. 76 NFPA [Section No ] Public Input No. 132 NFPA [Section No ] Public Input No. 190 NFPA [Section No. 12.2] Public Input No. 73 NFPA [Section No ] Ballot Results This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M. King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F /286

224 Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 220/286

225 First Revision No. 86 NFPA [ New Section after 12.3 ] 12.8 Biological Decontamination Efficacy Test Application. This test method shall apply to the decontamination of outer shell material that is subjected to ISP cleaning procedures for advanced cleaning employed for the disinfection or sanitization of structural fire fighting protective garments Samples. Pristine 100 mm (4.0 in.) diameter surrogate outer shell material samples shall be laundered ten times in accordance with of NFPA Specimens. A total of 12 pieces of surrogate outer shell material shall be tested Procedure Testing shall be performed in accordance with ASTM E2274, Standard Test Method for Evaluation of Laundry Sanitizers and Disinfectants, or ASTM E2406, Standard Test Method for Evaluation of Laundry Sanitizers and Disinfectants for Use in High Efficiency Washing Operations, with the following modifications: (1) The test microorganisms shall be Klebsiella pneumoniae, Staphylococcus aureus, Pseudomonas aeruginosa, and Bacillus subtilis spores. (2) Three specimens shall be individually inoculated with each test microorganism. (3) Growth or no growth shall be recorded after a 48 hour incubation period. (4) A polymerase chain reaction detection method shall be used to identify and quantify the levels of microorganism present on the test specimens. (5) A minimum average of CFU/carrier shall be recovered for a valid test. A minimum average of CFU/mL in the wash water control shall be recovered for a valid test Inoculated specimens shall be placed inside a protective clothing sample Report The individual microbial counts shall be reported for each specimen The average microbial counts shall be reported for each test microorganism The average log10 reduction shall be calculated and reported for each test microorganism Interpretation. Passing or failing performance shall be based on the average log10 reduction for each test microorganism. Supplemental Information 221/286

226 File Name FR_86_12.8.docx Description Approved For staff use Submitter Information Verification Submitter Full Name: Chris Farrell Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sat Apr 15 22:17:16 EDT 2017 Committee Statement Committee Specific procedures for validating the effectiveness of cleaning ensemble elements, Statement: primarily protective garments and hoods, for removal of combustion products and associated contamination in addition to separate procedures for the sanitization of protective elements for biological contamination are proposed. Specific research is being carried out to develop simplified procedures by which specially contaminated samples can be sent to any facility and subjected to a respective organization s cleaning process and procedures. The facility would then return the cleaned samples back to a qualified laboratory for analysis. Based on the analysis of the samples, a determination can be made as to how much contamination has been removed by the respective cleaning process are procedures. Is recommended that these validation procedures be specified for qualifying specific cleaning and decontamination processes as applied to the removal of products of combustion contamination and separately to biological contamination. Thus, only those equipment, cleaning agents/sanitizers, procedures and processes that pertain a specific level of contamination removal efficiency would be used. Work is already underway by the Fire Protection Research Foundation and is sufficiently advanced for developing procedures that examines both chemical and biological contamination. In the case of chemical contamination, two separate approaches are being investigated. The first approach entails exposing small material swatches in a repeatable fashion to products of combustion created and a small controlled chamber that creates both soot particles and various types of organic and inorganic chemicals. A second approach involves impregnating fabric samples with a certain like carbon material and inoculating the material with specific amounts of known organic and inorganic chemicals. In while either case, the contaminated samples would be characterized for the levels contamination an identical set would be sent to the facility for incorporation into a clothing set that is then subjected to the respective cleaning process being evaluated. With the return of the wash samples, and analysis would be performed to determine the remaining level of contaminants retained by the sample. By comparing the levels both in the uncleaned and cleaned samples, a quantitative measure can be obtained for individual substances or contaminants. Similarly, specimen fabric samples can be inoculated with specific microorganisms and likewise subjected to cleaning or sanitization processes to determine the remaining number of microorganisms following the application the process. Specific efficiencies can be set for qualifying the effectiveness of the decontamination processes for either chemical or biological contaminants. The inclusion of cleaning validation will be proposed in the following ways: 1. All advanced cleaning processes would be required to be validated for effectiveness for chemical decontamination. 2. Any cleaning process recommended for the removal biological contaminants would be required to be validated for effectiveness for biological decontamination /286

227 Response Message: Ballot Results 3. It would be permitted for vendors to qualify their equipment, cleaning/sanitization, and specialized processes for either chemical or biological decontamination effectiveness. 4. These procedures would be applied to Independent Service Providers to verify their cleaning as no such current procedures exist and would be undertaken during the verification process applied to ISPs. Specific details for how these requirements would be implemented as well as current proposed procedures for the conduct of both chemical and biological contamination will be specified prior to the first draft meeting to allow committee review of the recommended changes to the standard. This item has passed ballot 35 Eligible Voters 3 Not Returned 31 Affirmative All 1 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Ott, Louis V. Putorti, Jr., Anthony D. Sisson, Kelly Affirmative All Allen, Jason L. Berger, George E. Corrado, Steven D. Curtis, Paul F. Deaton, Anthoney Shawn Durby, Tim Fanning, David P. Fesik, Jonathan Fithian, William A. Freeman, Patricia A. Harkness, A. Ira Haskell, III, William E. Hayden, Earl Karban, John M /286

228 King, Stephen J. Klaren, Kim Lakey, Steve L. Lehtonen, Karen E. McKenna, Michael F. Necklaus, Gene Ragan, Tom Reidy, Jim Rihn, John F. Robison, R. Wendell Stull, Jeffrey O. Tomlinson, Tim W. Tutterow, Jr., Robert D. Walter, James A. Weise, Richard Winer, Harry P. Woods, Patrick J. Affirmative with Comment Granger, Jr., Richard O. OK 224/286

229 First Revision No. 87 NFPA [ New Section after 12.3 ] 12.7 Chemical Decontamination Efficacy Test Application. This test method shall apply to the decontamination of outer shell material that is subjected to ISP cleaning procedures for advanced cleaning employed for the removal of products of combustion from structural fire fighting protective garments Samples. Pristine 100 mm (4.0 in.) diameter surrogate outer shell material samples shall be laundered ten times in accordance with of NFPA Specimens. A total of 12 pieces of surrogate outer shell material shall be tested Procedure Six specimens shall be mounted to the lower mounting stage of a Martindale abrasion machine Specimens shall be loaded with 0.05 g ± g each of 99.9 percent acetylene based carbon black for 80 cycles utilizing 9 kpa head pressure. The top abradant head shall be the 30 mm (1.2 in.) diameter stainless steel head only All 12 specimens shall be contaminated with the chemical quantities as specified in Table Table Selected Surrogate Chemical Contaminants and Doses Specimens Chemical Amount 1 6 Pentachlorophenol 2.5 g of a 625 ppm standard 1 6 Phenanthrene 2.5 g of a 625 ppm standard 1 6 Octacosane 2.5 g of a 625 ppm standard 1 6 Naphthalene 2.5 g of a 625 ppm standard 1 6 Diethylhexyl phthalate 2.5 g of a 625 ppm standard 1 6 Xylene 2.5 g of a 625 ppm standard 1 6 2,2,4,4 Tetrabromodiphenyl ether 2.5 g of a 625 ppm standard 1 6 2,2,4,4,5,5 Hexachlorobiphenyl 2.5 g of a 625 ppm standard 7 12 Arsenic 600+/ 50 ng 7 12 Lead 600 +/ 50 ng Organic chemical contamination shall be performed by placing the fabric samples in largemouth jars and dripping the above specified quantity of a standard solution containing all of the target compounds on the carbon loaded portion of the fabric * Inorganic chemical contamination shall be performed utilizing the nebulizer from an ICP instrument to deposit the arsenic and lead to the carbon loaded surface of the fabric /286

230 All specimens shall be allowed to fully dry within a chemical hood for 24 hours Specimens shall be mounted on a standard protective coat that is certified to NFPA 1971, in the locations as shown in Figure , by fastening with a safety pin through the top and bottom of the circles to the outer shell. Figure Locations for Attachment of Contaminated Specimens The protective coat and surrogate specimen assembly shall be cleaned in accordance with the procedures of the ISP. Sufficient ballast of a suitable type shall be provided to make up a full load All six organic specimens shall be extracted using methylene chloride or another suitable methodology All six inorganic specimens shall be extracted using a suitable methodology Report The recovered quantity of each chemical in each individual specimen shall be reported Specimens 1 3 recovered quantities shall be averaged and compared by chemical versus the nonlaundered specimens 4 6 averages Specimens 7 9 recovered quantities shall be averaged and compared by chemical versus the nonlaundered specimens averages The average percent reduction for each chemical shall be reported as the decontamination efficiency of the ISP process Interpretation. Compliance with the pass/fail requirements shall be determined on the basis of each individual decontamination efficiency for all eight chemical contaminants. Supplemental Information File Name Description Approved 226/286

MEETING MINUTES OF THE TECHNICAL COMMITTEE ON STRUCTURAL AND PROXIMITY FIRE FIGHTING PROTECTIVE CLOTING AND EQUIPMENT JULY 26-28, 2011

MEETING MINUTES OF THE TECHNICAL COMMITTEE ON STRUCTURAL AND PROXIMITY FIRE FIGHTING PROTECTIVE CLOTING AND EQUIPMENT JULY 26-28, 2011 MEETING MINUTES OF THE TECHNICAL COMMITTEE ON STRUCTURAL AND PROXIMITY FIRE FIGHTING PROTECTIVE CLOTING AND EQUIPMENT JULY 26-28, 2011 PROVIDENCE HILTON PROVIDENCE, RI ROP MEETING FOR NFPA 1851 Tuesday,

More information

M E M O R A N D U M. NFPA 1801 Second Draft Technical Committee FINAL Ballot Results (A2017)

M E M O R A N D U M. NFPA 1801 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Electronic Safety

More information

NFPA CORRELATING COMMITTEE ON FIRE AND EMERGENCY SERVICES PROTECTIVE CLOTHING AND EQUIPMENT AGENDA JUNE 24-25, 2014 BLOOMINGTON, MN

NFPA CORRELATING COMMITTEE ON FIRE AND EMERGENCY SERVICES PROTECTIVE CLOTHING AND EQUIPMENT AGENDA JUNE 24-25, 2014 BLOOMINGTON, MN NFPA CORRELATING COMMITTEE ON FIRE AND EMERGENCY SERVICES PROTECTIVE CLOTHING AND EQUIPMENT AGENDA JUNE 24-25, 2014 BLOOMINGTON, MN 1. 9:00 AM - Call to Order - Chair Bill Haskell 2. Members and guests

More information

M E M O R A N D U M. Technical Committee on Industrial Fire Brigade Personnel Professional Qualifications

M E M O R A N D U M. Technical Committee on Industrial Fire Brigade Personnel Professional Qualifications National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Industrial Fire Brigade

More information

M E M O R A N D U M. Technical Committee on Fire Service Occupational Safety and Health

M E M O R A N D U M. Technical Committee on Fire Service Occupational Safety and Health National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Fire Service Occupational

More information

ISO INTERNATIONAL STANDARD. Medical laboratories Requirements for safety. Laboratoires de médecine Exigences pour la sécurité

ISO INTERNATIONAL STANDARD. Medical laboratories Requirements for safety. Laboratoires de médecine Exigences pour la sécurité INTERNATIONAL STANDARD ISO 15190 First edition 2003-10-15 Medical laboratories Requirements for safety Laboratoires de médecine Exigences pour la sécurité Reference number ISO 15190:2003(E) ISO 2003 PDF

More information

MEMORANDUM. NFPA Technical Committee on Fire Service Training. NFPA 1403 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Fire Service Training. NFPA 1403 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Service Training

More information

M E M O R A N D U M. Technical Committee on Hazardous Materials Response Personnel

M E M O R A N D U M. Technical Committee on Hazardous Materials Response Personnel National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Hazardous Materials

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 10 From: Kimberly Shea, Project Administrator

More information

TECHNICAL COMMITTEE ON EMERGENCY MEDICAL SERVICES PROTECTIVE CLOTHING AND EQUIPMENT. NFPA 1999 Pre-First Draft Meeting

TECHNICAL COMMITTEE ON EMERGENCY MEDICAL SERVICES PROTECTIVE CLOTHING AND EQUIPMENT. NFPA 1999 Pre-First Draft Meeting TECHNICAL COMMITTEE ON EMERGENCY MEDICAL SERVICES PROTECTIVE CLOTHING AND EQUIPMENT NFPA 1999 Pre-First Draft Meeting Hyatt Regency Crystal City 2799 Jefferson Davis Highway Arlington, VA 22202 December

More information

M E M O R A N D U M. Technical Committee on Aircraft Rescue and Fire Fighting. NFPA 403 Second Draft Technical Committee FINAL Ballot Results (A2017)

M E M O R A N D U M. Technical Committee on Aircraft Rescue and Fire Fighting. NFPA 403 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Aircraft Rescue and

More information

M E M O R A N D U M. Technical Committee on Public Emergency Service Communication

M E M O R A N D U M. Technical Committee on Public Emergency Service Communication National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Public Emergency

More information

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON SPECIAL OPERATIONS PROTECTIVE CLOTHING AND EQUIPMENT SAN DIEGO, CA MARCH 2012

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON SPECIAL OPERATIONS PROTECTIVE CLOTHING AND EQUIPMENT SAN DIEGO, CA MARCH 2012 MINUTES OF THE MEETING TECHNICAL COMMITTEE ON SPECIAL OPERATIONS PROTECTIVE CLOTHING AND EQUIPMENT SAN DIEGO, CA 14 -- 16 MARCH 2012 The meeting was called to order by Chairman Dean Cox at 08.00 on Wednesday,

More information

Technical Committee on Traffic Control Incident Management Professional Qualifications. First Draft Meeting - NFPA Agenda

Technical Committee on Traffic Control Incident Management Professional Qualifications. First Draft Meeting - NFPA Agenda Technical Committee on Traffic Control Incident Management Professional Qualifications 1. Call to Order Chair Steve Austin 2. Introduction of Members and Guests 3. Chair s Remarks and Purpose of Meeting

More information

M E M O R A N D U M. NFPA 1122 First Draft Technical Committee FINAL Ballot Results (A2017)

M E M O R A N D U M. NFPA 1122 First Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Pyrotechnics Yvonne

More information

Health, Safety, Security and Environment

Health, Safety, Security and Environment Document owner and change code Document Owner Aaron Perronne Title HSSE Manager Mark X Change Code Description X N/A First Issue A Typographical/Grammatical correction; formatting change; text clarification-no

More information

Personal Protective Equipment Program. Risk Management Services

Personal Protective Equipment Program. Risk Management Services Personal Protective Equipment Program Services Table of Contents I. Program Goals and Objectives... 2 II. Scope and Application... 2 III. Responsibilities... 2 IV. Procedures... 3 V. Training... 5 VI.

More information

MEMORANDUM. NFPA 85 BCS-SBB First Draft TC FINAL Ballot Results (F2014 Cycle)

MEMORANDUM. NFPA 85 BCS-SBB First Draft TC FINAL Ballot Results (F2014 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Single Burner Boilers

More information

Urinalysis and Body Fluids

Urinalysis and Body Fluids Urinalysis and Body Fluids Unit 1 A Safety in the Clinical Laboratory Types of Safety Hazards Physical risks Sharps hazard Electrical hazard Radioactive hazard Chemical exposure risk Fire / explosive hazards

More information

CHAPTER 2 INDUSTRIAL HYGIENE SURVEYS AND SURVEY REPORTS

CHAPTER 2 INDUSTRIAL HYGIENE SURVEYS AND SURVEY REPORTS CHAPTER 2 INDUSTRIAL HYGIENE SURVEYS AND SURVEY REPORTS 1. GENERAL. Industrial hygiene surveys are conducted to accurately assess worker exposures to chemical, physical and biological agents in the workplace

More information

WRITTEN HAZARD COMMUNICATION PROGRAM. Prepared for: BORO OF

WRITTEN HAZARD COMMUNICATION PROGRAM. Prepared for: BORO OF Prepared for: BORO OF 2013 TABLE OF CONTENTS INTRODUCTION...1 POLICY:...1 OBJECTIVE:...1 PURPOSE:...1 RESPONSIBLE PERSONS:...2 HAZARD DETERMINATION...3 PHYSICAL HAZARDS:...3 HEALTH HAZARDS:...4 EXEMPT

More information

PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards. Infection Prevention and Control: Personal Protective Equipment

PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards. Infection Prevention and Control: Personal Protective Equipment PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards : Personal Protective Equipment PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards 2016 PERSONAL PROTECTIVE EQUIPMENT Personal protective

More information

BLOODBORNE PATHOGENS

BLOODBORNE PATHOGENS BLOODBORNE PATHOGENS Supplement to Standard Training Module TRAINING REQUIREMENTS OVERVIEW This standard Vivid training module provides a general overview of Bloodborne Pathogens (BBP). It is important

More information

Agenda. 1. Call to Order Interim Chair Randall Bradley. 2. Introduction of Members and Guests. 3. Chair s Brief Remarks and Purpose of Meeting

Agenda. 1. Call to Order Interim Chair Randall Bradley. 2. Introduction of Members and Guests. 3. Chair s Brief Remarks and Purpose of Meeting Technical Committee for Wildland Fire Management Second Draft Meeting for NFPA 1143 Conference Call/Adobe Connect Connections October 10, 2016 2:00pm EST (11:00am PST) Connection will be provided through

More information

ASSE International Seal Control Board Procedures

ASSE International Seal Control Board Procedures ASSE International Seal Control Board Procedures 2014 PREAMBLE Written operating procedures shall govern the methods used for maintaining the product listing program and shall be available to any interested

More information

Hazmat Roles and Actions

Hazmat Roles and Actions 3.4.3.1 Hazmat Roles and Actions YOUR ORGANIZATION STANDARD OPERATING PROCEDURES/GUIDELINES TITLE: Hazmat Roles and Actions NUMBER: 3.4.3.1 PREPARED BY: SECTION/TOPIC: First Responder Operations ISSUE

More information

Hobart and William Smith Colleges. Personal Protective Equipment Program

Hobart and William Smith Colleges. Personal Protective Equipment Program Hobart and William Smith Colleges Geneva, New York Personal Protective Equipment Program Copies of the Personal Protective Equipment Program: 1. Human Resources Office 2. Office of the President (Provost)

More information

EPEAT Requirements of PREs

EPEAT Requirements of PREs EPEAT Requirements of PREs Published 26 January 2015 By The Green Electronics Council EPEAT Requirements of PREs Page 1 Context This EPEAT Requirements of PREs document is part of a set of documents that

More information

First Revision No. 2-NFPA [ Sections 1.1, 1.2, 1.3 ]

First Revision No. 2-NFPA [ Sections 1.1, 1.2, 1.3 ] First Revision No. 2-NFPA 1091-2013 [ Sections 1.1, 1.2, 1.3 ] 1.1 Scope. This standard identifies the minimum job performance requirements (JPRs) necessary to perform temporary traffic control duties

More information

Formaldehyde Exposure Control Policy

Formaldehyde Exposure Control Policy Formaldehyde Exposure Control Policy POLICY AND PROCEDURES FOR WORKING WITH FORMALDEHYDE Policy: It is Columbia University (CU) policy to maintain formaldehyde exposure below the action level (AL) 0.5

More information

CHEMICAL HYGIENE PLAN

CHEMICAL HYGIENE PLAN CHEMICAL HYGIENE PLAN The SDSU Laboratory Chemical Safety Program for Compliance with 29 CFR 1910.1450 and 8 CCR 5191: Occupational Exposure to Hazardous Chemical in Laboratories Prepared by San Diego

More information

CHEMICAL HYGIENE PLAN

CHEMICAL HYGIENE PLAN SAMPLE WRITTEN CHEMICAL HYGIENE PLAN For Compliance With 29 CFR 1910.1450 Wyoming General Rules and Regulations Wyoming Department of Workforce Services OSHA Division Consultation Program ACKNOWLEDGEMENTS

More information

Respiratory Protection Plan

Respiratory Protection Plan Respiratory Protection Plan Contents: Sample Respiratory Protection Plan Introduction... ii Plan Cover Sheet... 1 Policy... 2 Responsibility... 2 Plan Elements... 3 Organizational Responsibility Chart...

More information

PROCEDURE FOR THE PREPARATION AND FOLLOW-UP OF AN AGENCY FOR TOXIC SUBSTANCES AND DISEASE REGISTRY (ATSDR) PUBLIC HEALTH ASSESSMENT

PROCEDURE FOR THE PREPARATION AND FOLLOW-UP OF AN AGENCY FOR TOXIC SUBSTANCES AND DISEASE REGISTRY (ATSDR) PUBLIC HEALTH ASSESSMENT PROCEDURE FOR THE PREPARATION AND FOLLOW-UP OF AN AGENCY FOR TOXIC SUBSTANCES AND DISEASE REGISTRY (ATSDR) PUBLIC HEALTH ASSESSMENT David F. McConaughy, MPH Navy and Marine Corps Public Health Center,

More information

Pharmacy Sterile Compounding Areas

Pharmacy Sterile Compounding Areas Approved by: Pharmacy Sterile Compounding Areas Corporate Director, Environmental Supports Environmental Services/ Nutrition Food Services Operating Standards Manual Number: Date Approved June 17, 2016

More information

MODULE 3 HAZARDOUS MATERIAL OPERATIONS NFPA MISSION-SPECIFIC RESPONSIBILITIES

MODULE 3 HAZARDOUS MATERIAL OPERATIONS NFPA MISSION-SPECIFIC RESPONSIBILITIES MODULE 3 HAZARDOUS MATERIAL OPERATIONS NFPA MISSION-SPECIFIC RESPONSIBILITIES 1 ACKNOWLEDGEMENTS This course and participant s manual were developed and produced for the training of Operations level responders.

More information

Health and Safety in the lab. Seyed Hosseini SA Pathology Chemical Pathology

Health and Safety in the lab. Seyed Hosseini SA Pathology Chemical Pathology Health and Safety in the lab Seyed Hosseini SA Pathology Chemical Pathology ISO 15190 This International Standard specifies requirements to establish and maintain a safe working environment in a medical

More information

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control Ministry of Labour Occupational Health & Safety and Infection Prevention & Control Presentation to Northern Ontario ICN September 23, 2011 Denise Madsen, RN, BScN, CIC Infection Control Consultant Northern

More information

Personal Hygiene & Protective Equipment. NEO111 M. Jorgenson, RN BSN

Personal Hygiene & Protective Equipment. NEO111 M. Jorgenson, RN BSN Personal Hygiene & Protective Equipment NEO111 M. Jorgenson, RN BSN Hand Hygiene the single most effective way to help prevent the spread of infections agents. (CDC, 2002.) Consistency & Compliancy 50%

More information

SARASOTA MEMORIAL HOSPITAL

SARASOTA MEMORIAL HOSPITAL SARASOTA MEMORIAL HOSPITAL TITLE: NURSING PROCEDURE HANDLING LIQUID CHEMOTHERAPY SPILLS DATE: REVIEWED: PAGES: 03/86 11/17 1 of 6 PS1094 ISSUED FOR: Nursing RESPONSIBILITY: RN PURPOSE: OBJECTIVE: KNOWLEDGE

More information

Is Your Respirator Really Protecting You?

Is Your Respirator Really Protecting You? Is Your Respirator Really Protecting You? 2018 Wisconsin Safety Council Safety & Health Conference, Presentation by Tim Gackle, OSHA Training Institute April 18, 2018 1 Objectives Define Respirator Discuss

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM RESPIRATORY PROTECTION PROGRAM 1.0 PURPOSE The purpose of this Respiratory Protection Program is to protect respirator users at California State University East Bay from breathing harmful airborne contaminants

More information

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017 Page 1 of 8 Policy Applies to: All Mercy Staff, Credentialed Specialists, Allied Health Professionals, students, patients, visitors and contractors will be supported to meet policy requirements Related

More information

Robert H. Hill, Jr. Battelle Atlanta, Georgia

Robert H. Hill, Jr. Battelle Atlanta, Georgia Robert H. Hill, Jr. Battelle Atlanta, Georgia Graduate students conducting research same institution, department 1 st Student Reaction exploded; acid splash in eyes, severely cut arm 2 nd Student, 5 mos.

More information

Respiratory Protection Program

Respiratory Protection Program Respiratory Protection Program July 2016 Table of Contents Purpose... 1 Scope and Application... 1 Responsibilities... 2 Program Administrator... 2 Directors/Supervisors... 2 Employees... 2 Program Elements...

More information

RESPIRATORY PROTECTION

RESPIRATORY PROTECTION RESPIRATORY PROTECTION 29 CFR 1910.134 OSHA law requires that engineering controls rather than respirators be used to solve most air contamination problems. Respirators are too often used as a permanent

More information

NORTH CAROLINA A&T STATE UNIVERSITY Chemical Hygiene Plan

NORTH CAROLINA A&T STATE UNIVERSITY Chemical Hygiene Plan North Carolina Agricultural and Technical State University OFFICE OF ENVIRONMENTAL HEALTH & SAFETY Safety Manual Subject: Chemical Hygiene Plan Number: 5-1 Date February 1, 2009 Amends: None Supersedes:

More information

Ensuring Healthcare Worker Safety When Handling Hazardous Drugs: The Joint Position Statement From the Oncology Nursing Society, the American

Ensuring Healthcare Worker Safety When Handling Hazardous Drugs: The Joint Position Statement From the Oncology Nursing Society, the American Ensuring Healthcare Worker Safety When Handling Hazardous Drugs: The Joint Position Statement From the Oncology Nursing Society, the American Society of Clinical Oncology, and the Hematology/Oncology Pharmacy

More information

Policy - Infection Control, Safety and Personal Security

Policy - Infection Control, Safety and Personal Security Policy - Infection Control, Safety and Personal Security Origin Date: October 28, 2013 Last Evaluated: April 2018 Responsible Party: Program Director Minimum Review Frequency: Annually Approving Body:

More information

Body of Knowledge. Respiratory Protection Program Administration and Fit Testing

Body of Knowledge. Respiratory Protection Program Administration and Fit Testing Body of Knowledge Respiratory Protection Program Administration and Fit Testing About AIHA Founded in 1939, the American Industrial Hygiene Association (AIHA ) is one of the largest international associations

More information

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE. AGENDA October 23, 2013 Teleconference/Web Meeting

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE. AGENDA October 23, 2013 Teleconference/Web Meeting National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-104101 Phone: 6110-10100-3000 Fax: 6110-10100-01000 www.nfpa.org NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA October

More information

May 4, The Honorable John Conyers, Jr. United States House of Representatives Washington, DC Dear Representative Conyers:

May 4, The Honorable John Conyers, Jr. United States House of Representatives Washington, DC Dear Representative Conyers: Your Essential Connection May 4, 2005 The Honorable John Conyers, Jr. United States House of Representatives Washington, DC 20515-2214 Dear Representative Conyers: The American Industrial Hygiene Association

More information

Laboratory Safety Chemical Hygiene Plan (CHP)

Laboratory Safety Chemical Hygiene Plan (CHP) Laboratory Safety Chemical Hygiene Plan (CHP) The Occupational Safety and Health Administration s (OSHA) Occupational Exposure to Hazardous Chemicals in Laboratories standard (29 CFR 1910.1450), referred

More information

OSHA Preparedness. Presented by: Dave Lall, CEO, DEMILEC (USA) LLC

OSHA Preparedness. Presented by: Dave Lall, CEO, DEMILEC (USA) LLC OSHA Preparedness Presented by: Dave Lall, CEO, DEMILEC (USA) LLC Safety Manual A Safety Manual is not required by OSHA, but a Written Respiratory Protection Program is. It is much easier to incorporate

More information

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: NEC Code-Making Panel 15 FROM: Kimberly Shea, Administrator, Technical

More information

Respiratory Protection Safety Program

Respiratory Protection Safety Program Purpose Document location: P:\ASDAEH\^Risk Management^\Respiratory Safety The purpose of Florida Gulf Coast University s is to enhance the protection of employee health by ensuring proper training, selecting

More information

New OSHA Chemical Standard: What All Labs Need to Know!

New OSHA Chemical Standard: What All Labs Need to Know! Speaker 2013 Webinar Series New OSHA Chemical Standard: What All Labs Need to Know! September 19, 2013 Eric Clark, MS, Safety Officer, Los Angeles County, Downey, CA Eric Clark earned his MS in Analytical

More information

Control of Substances Hazardous to Health (COSHH)

Control of Substances Hazardous to Health (COSHH) Control of Substances Hazardous to Health (COSHH) 1. PURPOSE 1.1 The Control of Substance Hazardous to Health regulations are the main piece of legislation covering control of the risks to staff and other

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 1 From: Kimberly Shea, Project Administrator

More information

Certified Healthcare Safety Environmental Services (CHS-EVS) Examination Blueprint/Outline

Certified Healthcare Safety Environmental Services (CHS-EVS) Examination Blueprint/Outline Certified Healthcare Safety Environmental Services (CHS-EVS) Examination Blueprint/Outline Exam Domains 100-130 1. Safety Management 38-50 (38%) 2. Hazard Control 38-50 (38%) 3. Compliance & Voluntary

More information

Policy - Infection Control, Safety and Personal Security

Policy - Infection Control, Safety and Personal Security Policy - Infection Control, Safety and Personal Security Origin Date: October 28, 2013 Last Evaluated: February 5, 2015 Responsible Party: Director of Didactic Education Minimum Review Frequency: Annually

More information

Implementing USP

Implementing USP Implementing USP 800 Joanna Robinson, PharmD, MS Inpatient Operations Manager Disclosure I have no conflicts of interest to disclose Objectives 1. Understand the purpose of USP 80 2. Describe how to engage

More information

Occupational Health - Industrial Hygiene. Objectives:

Occupational Health - Industrial Hygiene. Objectives: Occupational Health - Industrial Hygiene Objectives: Students should be able to describe: The role of occupational health practice within the community Inter-relation between OH and preventive health practices.

More information

West Virginia University

West Virginia University West Virginia University Environmental Health and Safety RESPIRATORY PROTECTION PROGRAM Revised January 2017 West Virginia University P.O Box 6551 Morgantown WV 26506 # 304-293-3792 Fax 304-293-7257 http://ehs.wvu.edu

More information

ANSWERING TO A HIGHER CALLING

ANSWERING TO A HIGHER CALLING ANSWERING TO A HIGHER CALLING Verifying Laundry Processes, Quantifying Cleanliness Quality Assurance Best Management Practices Continuous Improvement Process and Outcome Measures ANSWERING TO A HIGHER

More information

Bloodborne Pathogens Exposure Control Plan Dumas Independent School District

Bloodborne Pathogens Exposure Control Plan Dumas Independent School District Bloodborne Pathogens Exposure Control Plan Dumas Independent School District Part I: Purpose The purpose of this exposure control plan is to eliminate or minimize work-related exposure to bloodborne pathogens,

More information

Oregon Health & Science University Department of Surgery Standard Precautions Policy

Oregon Health & Science University Department of Surgery Standard Precautions Policy Standard Precautions Policy 1. Policy Standard Precautions are to be followed by all employees for all patients within and entering the OHSU system. Standard Precautions are designed to reduce the risk

More information

SECTION 6 PERSONAL PROTECTIVE EQUIPMENT (PPE)

SECTION 6 PERSONAL PROTECTIVE EQUIPMENT (PPE) SECTION 6 PERSONAL PROTECTIVE EQUIPMENT (PPE) 6.1 Personal Protective Equipment 6.2 Respiratory Protection Program 6.3 Information for Voluntary Use of Respirators 6.4 Hearing Conservation Program Reviewed:

More information

Control of Substances Hazardous to Health (COSHH) Procedure

Control of Substances Hazardous to Health (COSHH) Procedure Control of Substances Hazardous to Health (COSHH) Procedure Objective The purpose of this procedure is: To ensure that the necessary use of substances hazardous to health is safe and controlled. To ensure

More information

CHABOT/LAS POSITAS COMMUNITY COLLEGE DISTRICT

CHABOT/LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT/LAS POSITAS COMMUNITY COLLEGE DISTRICT HAZARD COMMUNICATION PLAN Chabot/Las Positas Community College District Hazard Communication Program 2/2007 Pg 1 of 7 Hazard Communication Program Policy Policy

More information

Infection Control in the Hearing Aid Clinic What is infection control & why should we care?

Infection Control in the Hearing Aid Clinic What is infection control & why should we care? Infection Control in the Hearing Aid Clinic What is infection control & why should we care? OBJECTIVES What do we need to do? A.U. Bankaitis, PhD, FAAA Vice President & General Manager Oaktree Products,

More information

2014 Annual Continuing Education Module. Contents

2014 Annual Continuing Education Module. Contents This self-directed learning module contains information you are expected to know to protect yourself, our patients, and our guests. Content Experts: Infection Prevention Target Audience: All Teammates

More information

TRINIDAD AND TOBAGO BUREAU OF STANDARDS

TRINIDAD AND TOBAGO BUREAU OF STANDARDS TRINIDAD AND TOBAGO BUREAU OF STANDARDS STANDARDS WORK PROGRAMME FOR THE PERIOD APRIL 2018 SEPTEMBER 2018 Date: 2018-04-13 TRINIDAD AND TOBAGO BUREAU OF STANDARDS Location: 1-2 Century Drive Trincity Industrial

More information

PRECAUTIONS IN INFECTION CONTROL

PRECAUTIONS IN INFECTION CONTROL PRECAUTIONS IN INFECTION CONTROL Standard precautions Transmission-based precautions Contact precautions Airborne precautions Droplet precautions 1 2/25/2015 WHO HAVE TO PROTECT IN HOSPITALS? Patients

More information

PERSONAL PROTECTIVE EQUIPMENT (PPE) Standard Operating Guidance

PERSONAL PROTECTIVE EQUIPMENT (PPE) Standard Operating Guidance Revision Date: 27OCT2014 Hazard ID: P/H Incident EBOLA Annex A 1 PPE Revised By: PERSONAL PROTECTIVE EQUIPMENT (PPE) Standard Operating Guidance Use By: Response personnel required to don and doff PPE

More information

OH&ESD. Technical Data Bulletin

OH&ESD. Technical Data Bulletin 3 Technical Data Bulletin OH&ESD #160 Reusable Respirator Facepieces and Powered Air Purifying Respirator Systems (PAPRs) in the Health Care Environment: Considerations for Use Published: August, 2003

More information

DRAFT. FIRESCOPE JOINT OPERATIONS TEAM MEETING Quincy July 9-10, 1998

DRAFT. FIRESCOPE JOINT OPERATIONS TEAM MEETING Quincy July 9-10, 1998 ATIENDEES: DRAFT FIRESCOPE JOINT OPERATIONS TEAM MEETING Quincy July 9-10, 1998 Pat Cooney, OES Chris Wurzell, CDF Jeff Jones, CDF Jack Hickey, Davis FD Jim Marquis, OES Mike Colgan, ORC Hank Weston, GVFD

More information

SAFETY REQUIREMENTS UCLA DEPARTMENT OF CHEMISTRY AND BIOCHEMISTRY

SAFETY REQUIREMENTS UCLA DEPARTMENT OF CHEMISTRY AND BIOCHEMISTRY SAFETY REQUIREMENTS UCLA DEPARTMENT OF CHEMISTRY AND BIOCHEMISTRY On July 25, 2012 the Regents and Chancellor Block signed a Settlement Agreement with the Los Angeles District Attorney that terminated

More information

TRINIDAD AND TOBAGO BUREAU OF STANDARDS

TRINIDAD AND TOBAGO BUREAU OF STANDARDS TRINIDAD AND TOBAGO BUREAU OF STANDARDS STANDARDS WORK PROGRAMME APRIL 2016 SEPTEMBER 2016 (STATUS AS OF APRIL 2016) Date: 2016-04-12 TRINIDAD AND TOBAGO BUREAU OF STANDARDS Location: 1-2 Century Drive

More information

Does this topic relate to the work the crew is doing? If not, choose another topic.

Does this topic relate to the work the crew is doing? If not, choose another topic. TRAINING GUIDE RESPIRATORS 1994 Before you begin the meeting... Does this topic relate to the work the crew is doing? If not, choose another topic. Did you read this Training Guide and fill in the blanks

More information

TECHNICAL COMMITTEE ON TRANSPORTATION OF FLAMMABLE LIQUIDS

TECHNICAL COMMITTEE ON TRANSPORTATION OF FLAMMABLE LIQUIDS TECHNICAL COMMITTEE ON TRANSPORTATION OF FLAMMABLE LIQUIDS MEMORANDUM TO: FROM: Technical Committee on Transportation of Flammable Liquids R. P. Benedetti DATE: May 29, 2015 SUBJECT: Agenda for NFPA 385

More information

Level 2 Award in Health and Safety in Health and Social Care

Level 2 Award in Health and Safety in Health and Social Care Level 2 Award in Health and Safety in Health and Social Care Accidents and ill-health Accidents in the workplace Typically, the most common causes of injury to employees in health and social care are due

More information

Respiratory Protection Program

Respiratory Protection Program Respiratory Protection Program Office of Environmental Health and Safety Revised July, 2012 Cleveland State University Respiratory Protection Program 1 Cleveland State University Respiratory Protection

More information

SANDBLASTING CONTROL PLAN

SANDBLASTING CONTROL PLAN SANDBLASTING CONTROL PLAN Steingass Mechanical Contracting, Inc. 754 Progress Drive Medina, Ohio 44256 (330) 725-6090 1 Purpose The Sandblasting Control Plan establishes mandatory guidelines to protect

More information

Laboratory Chemical Hygiene Plan Research Lab

Laboratory Chemical Hygiene Plan Research Lab Laboratory Chemical Hygiene Plan Research Lab A chemical hygiene plan is a written program developed to establish procedures, protective equipment requirements and standard work practices that promote

More information

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157 Fall 2010 HOLLY ALEXANDER Academic Coordinator of Clinical Education 609-570-3478 AlexandH@mccc.edu MS157 To reduce infection & prevent disease transmission Nosocomial Infection: an infection acquired

More information

INDIVIDUAL PROTECTION

INDIVIDUAL PROTECTION Joint Program Executive Office for Chemical and Biological Defense Joint Science and Technology Office INDIVIDUAL PROTECTION April 4, 2007 Advanced Planning Briefing to Industry MR. JAMES L. NELSON, JR.

More information

Health And Safety Instructions On Cleaning >>>CLICK HERE<<<

Health And Safety Instructions On Cleaning >>>CLICK HERE<<< Health And Safety Instructions On Cleaning Materials At Home Identify the risks involved with window cleaning, choose the right access equipment to do the job. Vaccine Safety Guidelines for Flu Vaccination

More information

Everyone Involved in providing healthcare should adhere to the principals of infection control.

Everyone Involved in providing healthcare should adhere to the principals of infection control. Infection Control Introduction The prevention and control of infection is an integral part of the role of all health care personnel. Healthcare Associated Infections (HCAIs) affect an estimated one in

More information

PEMBERTON TOWNSHIP VOLUNTEER FIRE DEPARTMENT STANDARD OPERATING PROCEDURES EFFECTIVE DATE 9/27/2010

PEMBERTON TOWNSHIP VOLUNTEER FIRE DEPARTMENT STANDARD OPERATING PROCEDURES EFFECTIVE DATE 9/27/2010 PEMBERTON TOWNSHIP VOLUNTEER FIRE DEPARTMENT STANDARD OPERATING PROCEDURES EFFECTIVE DATE 9/27/2010 Revised Date 3/12/2011 Pemberton Township Fire Department Organizational Chart Fire Director Vacant Craig

More information

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings : Program Goal Improve personnel safety in the healthcare environment through appropriate use of PPE. :

More information

Hazardous Materials/Weapons of Mass Destruction Mission Specific Competencies (Chapter 6)

Hazardous Materials/Weapons of Mass Destruction Mission Specific Competencies (Chapter 6) Standardized Curriculum Form Ontario, Canada Office of the Fire Marshal and Emergency Management Curriculum based on NFPA 472, Chapter 6.3, 6.4, 6.7, 6.8 and 6.9, 2013 Edition Hazardous Materials/Weapons

More information

Conformity Assessment Approaches and Best Practices NIST Public Workshop. Session 4: Conformity Assessment Case Study Personal Protective Technologies

Conformity Assessment Approaches and Best Practices NIST Public Workshop. Session 4: Conformity Assessment Case Study Personal Protective Technologies Conformity Assessment Approaches and Best Practices NIST Public Workshop Session 4: Conformity Assessment Case Study Personal Protective Technologies Maryann D Alessandro, Ph.D. Director, National Personal

More information

HAZARDOUS MATERIAL (HAZMAT) INCIDENTS

HAZARDOUS MATERIAL (HAZMAT) INCIDENTS Policy 706 Subject HAZARDOUS MATERIAL (HAZMAT) INCIDENTS Date Published Page 27 September 2017 1 of 6 By Order of the Police Commissioner POLICY Public Safety. It is the policy of the Baltimore Police

More information

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY Department: Neurology (Hemby Lane) Date Originated: 2/20/14 Date Reviewed: 6.5.18 Date Approved: 6/3/14 Page 1 of 7 Approved by: Department Chairman Administrator/Manager

More information

Oak Grove School District Respiratory Protection Program

Oak Grove School District Respiratory Protection Program Oak Grove School District Respiratory Protection Program District Policy The purpose of this notice is to inform you that Oak Grove School District is complying with the OSHA Respiratory protection Standard,

More information

COSHH - Fundamentals of Risk Assessment and Control Qualification specification

COSHH - Fundamentals of Risk Assessment and Control Qualification specification P304 Proficiency Qualification COSHH - Fundamentals of Risk Assessment and Control Qualification specification Issue 1 January 2016 Issue 2 February 2018 Contents Page Section 1 About BOHS 2 Section 2

More information

Observations will be made of the storage. knowledge of the hazardous materials. labeling the container to the use of. containers (which may range from

Observations will be made of the storage. knowledge of the hazardous materials. labeling the container to the use of. containers (which may range from PHYSICAL ENVIRONMENT STANDARD / ELEMENT EXPLANATION SCORING PROCEDURE SCORE 11.05.06 Hazardous Materials - Routine Monitoring. Monitoring of hazardous materials and wastes is conducted to reduce the exposure

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Page 1 of 12 ISSUED: 6/94 REVISED: 06/07 Introduction: Purpose The purpose of this program is to ensure the protection of all employees from respiratory hazards through the proper use of respirators. Respirators

More information

Environmental Health & Safety Respiratory Protection and Use Policy

Environmental Health & Safety Respiratory Protection and Use Policy **Printed copies of this document are uncontrolled, visit the EHS website at http://www.wright.edu/admin/ehs/ for the latest revision** I. Purpose The purpose of the Respiratory Protection Program is to

More information