NOTE ON PERFORMANCE TESTING

Similar documents
NOTE ON PERFORMANCE TESTING

Pipeline Operational Qualification (OQ) Crosswalks

National Center for Construction Education and Research (NCCER) Webinar for NCCER Craft Instructors Fall 2018

1. Perform maintenance tasks associated with L120 and SMB actuators: 3. Evaluate L120 and SMB actuators for correct operation.

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

NCCER Accredited Training Sponsor Toolkit

BUILDING OFFICIALS ASSOCIATION OF FLORIDA CROSS TRAINING PROGRAM SYLLABUS. Electrical Plans Examiner Training Program

INSTRUMENTATION TECHNICIAN I/II/III

NCCER Accredited Training Sponsor

A. General provisions and other electrical systems are specified in other Sections of Division 26.

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

The University of Texas at San Antonio

RTD or Thermocouple / Well Assembly

B. All of the documents in this RFP form the Basis-of-Design for this project.

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

1.5 to 5 Tons INDOOR COILS C33. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ELECTRICAL TECHNICIAN I/II/III

Specifications, Performance & Submittal

LIST OF EFFECTIVE PAGES. Cover Sheet 0 LEP 0 Table of Contents 0 4 thru 9 0. AG-009 Rev. 0 Page 2 of 19

RELIABILITY CONSIDERATIONS FOR LAUNCH VEHICLE COMMAND DESTRUCT SYSTEMS

Gasket Failure Causes Leak

AIR CONDITIONER HORIZONTAL, COMPACT, 9,000 BTU/HR, 115 VOLT SINGLE PHASE 50/60 HERTZ PART NO. S8450-9KC-1H (NSN ) (EIC: N/A)

TAHOE CITY PUBLIC UTILITY DISTRICT Job Description

UNIFIED FACILITIES GUIDE SPECIFICATION

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1041 ASPHALT CONCRETE QUALITY ASSURANCE PROGRAM ADMINISTRATION.

WLDG 2443 ADVANCED SHIELD METAL ARC WELD (PLATE)

NAVSEA STANDARD ITEMS FY-19 CH-2 (26 MAR 2018)

Attachment D. Paramedic

TRAINING AND DEVELOPMENT PLAN B102

The University of Texas at San Antonio

Parts List. Commercial Series Refrigerated Kitchen Equipment

GE Energy Connections

Attachment D. Paramedic. Updated 1/2015 1

ARMY TM AIR FORCE TO-35C NAVY NAVFAC P

Part I Assessment Summary

Course Outline (Winter 2017)

ELECTRONICS TECHNICIAN I ELECTRONICS TECHNICIAN II

MINUTES JOINT MEETING FINANCE AND CONSTRUCTION COMMITTEES UNIVERSITY OF SOUTHERN INDIANA BOARD OF TRUSTEES. July 13, 2000

1. General. 2. Background

Fluorine Gas Mist Pot Fails

CUE DATA REQUEST CUE-SCG-DR-10 UTILITIES 2019 GRC A SOCALGAS / SDG&E RESPONSE DATE RECEIVED: MAY 4, 2018 DATE RESPONDED: MAY 10, 2018

Electrical Safety and Testing Components published in Gazette Notice 1 December 2011

A M E R I C A N S A F E T Y & H E A LT H I N S T I T U T E

WLDG 1428 Introduction to Shielded Metal Arc Welding

Buck & Boost Transformer Installation Instructions

HELICOPTER MECHANIC, HELICOPTER MECHANIC SUPERVISOR, 3749

Easylink to Square D Module

First Aid/CPR Training Program Application Packet

COMDTPUB P16721 NVIC August 25, 2014

Southface LEED for Homes 2017 Quality Assurance Plan

DEPARTMENT OF THE ARMY TECHNICAL MANUAL *TM DEPARTMENT OF THE AIR FORCE TECHNICAL ORDER TECHNICAL MANUAL

Panel Manager Observation Checklist

/ I N S T I T U T E t r a i n i n g c a t a l o g f a l l 2015

Safety Innovations FOUNDATIONHTSI. Nine Recommendations To Prevent Multiple Line Infusion Medication Errors

6-3 [D5A0] WIRING DIAGRAM. 5. Wiring Diagram. 5. Wiring Diagram A: POWER SUPPLY ROUTING

Roots HCM Product Family

QUALITY ASSURANCE ASSESSMENT

APPRENTICESHIP PROGRAM FOR MOS OF AIR TRAFFIC CONTROL NAVIGATIONAL AIDS TECHNICIAN

BP HUSKY TOLEDO REFINERY

Business. Ms. Hardin. Business Principles & Applications. Suggested Grade Level: Prerequisite: None. Credit: 1.0

NEA07 LABORATORY PRACTICAL EVALUATION. EXAM # NEA07P00107 COURSE TITLE: Electronic Controls

ES-301 Administrative Topics Outline Form ES-301-1

Preceptor Guidelines and Application

RFP for 2015 E-Rate Funded Wireless Upgrade Project at Four Locations In Thomasville City Schools RFP Reference# 2015Wireless Cabling Contact Mike

Document source:

PUBLIC COMPANY ORLEN LIETUVA OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-6/1 EQUIPMENT UNSEALING AND MAINTENANCE WORKS I. GENERAL PROVISIONS

WC-OSH 109 Tagging and Isolation

Medical Grade Power Strips

ATTACHMENT B. 1. Intent to Bid/Bidder Contact Information Form. 2. Executive Summary. 3. Proposal Characteristics and Term Sheet

TOP 10 DEFICIENCIES, SECOND QUARTER FY 2015.xls

Eastern Municipal Water District Date Adopted: 04/16/97 Date Revised: 07/06

ASA HEALTH AND SAFETY POLICY

YOU ARE INVITED EDUCATIONAL COURSES CREDITS OFFERED. IDN-H. Hoffman & ASSA ABLOY are proud to offer

SEMEM3-05 Carrying out fault diagnosis on mechanical equipment

PSA 2017 Paper Improved Tornado Missile Risk Analysis Using Nonlinear Finite Element Analysis of Nuclear Power Plant Structures.

Approved for public release. Distribution is unlimited.

1 What is an AAAHC/Medicare Deemed Status survey? 2 What are the Medicare Conditions for Coverage (CfC)?

WHEELING-OHIO COUNTY BOARD OF HEALTH WHEELING-OHIO COUNTY HEALTH DEPARTMENT

Outage dates (duration): September 5, 1996 to May 27, 1999 (2.7 years) Reactor age when outage began: 8.8 years

Recommendation: I will update the Board as necessary. Recommendation: I will update the Board as necessary. Total time 1.5 hours.

Curriculum For The LMA Supreme

Testing Fees Student Fee Amount

Design/Builder Qualifications Supplement (DBQS) Instructions. GENERAL INSTRUCTIONS UF-583, Ground Floor Renovation (Basic Science Bldg)

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

2 Quality Assurance In A Diagnostic Radiology Department. 1.1 Aim. 1.2 Introduction. 1.3 Key Elements of Quality assurance

2-DAYS OF EDUCATION TUESDAY, AUGUST 7, :00 AM - 5:00 PM TRADE SHOW WEDNESDAY, AUGUST 8, :00 AM - 2:00 PM YOU ARE CORDIALLY INVITED

Continuing Education Credits

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Guidance for Invigilators

HEADQUARTERS, DEPARTMENT OF THE ARMY

TM BD INTRODUCTION PAGE 1-1 TECHNICAL MANUAL ASSESSING BATTLEFIELD DAMAGE PAGE 2-1

OSHPD 3 CLINIC CERTIFICATION INSTRUCTIONS

IECEx OPERATIONAL DOCUMENT

Mobile X-Ray Machines

MEMORANDUM Department of Aging and Disability Services Regulatory Services Policy*Survey and Certification Clarification

Guidelines for Authorized Emergency Medical Services Continuing Education Providers

Incident Command System Awareness Participant Guide May 2016

Transcription:

NOTE ON PERFORMANCE TESTING Performance Profile Sheet(s) are included in a format that can be easily photocop ied for each trainee. Performance tests are designed to mea sure competency in the s taught in each module. Please note the number of s to be tested while teaching each module. Each trainee should be tested on all the s listed on the Performance Profile Sheet(s). Before performance, the instructor should brief the trainees on: Test objectives and criteria Safety precautions Procedures for each to be tested The instructor administering the performance should also do the following: Ensure that all of the needed equip ment is available and operating properly. Set up the stations. Organize and administer the test in a way that allows for optimal per for mance. Complete the Performance Profile Sheet(s) for each trainee by assigning a pass/fail score for each listed. Also, include the date for each in the rating box. Monitor adherence to all safety regulations and precautions. Provide adequate supervision to prevent injuries. Take immediate and effective action to remedy any emergency. Performance Testing If Performance Testing is done as part of the National Center for Construction Education and Research Standardized Craft Training Program, the following conditions must be met: 1. The Craft Instructor must hold valid NCCER instructor cer ti fi ca tion for the craft being tested. 2. The training must be delivered through a Accredited Training Sponsor recognized by NCCER. 3. For every module, the specific performance must be completed to the satisfaction of the instructor. 4. The results of the must be recorded on the Training Report Form 200. This form must be provided to the local Accredited Training Sponsor to be forwarded to the NCCER National Registry. Certified Plus Credential Provided the sponsor is working through an NCCER-Accredited Assessment Center, candidates who successfully pass performance may be eligible for a Certified Plus Credential. A number of NCCER s Performance Profiles cross over to NCCER s Assessment Performance Verifications and may be completed simultaneously. Go to www.nccer.org and select the Assessments tab to locate the Performance Verifications associated with this craft. Note two other important conditions are required for the Certified Plus Credential: 1. Candidates must first pass the associated written assessment. 2. An NCCER-Accredited Assessment Administrator must sign off on the Performance Verification before it is submitted to NCCER.

Module has no Performance Profile Sheet; no performance is required for this module.

Craft: Industrial Maintenance E & I Technician Module Number: 40207-08 Module Title: Process Mathematics Contren Learning Series Rating Levels: (1) Passed: performed (2) Failed: did not perform Rating Levels: (1) Also, Passed: list the performed date the for (2) each Failed: did was not completed. perform Recognition: Also, When list the date for the NCCER for Standardized each was Craft completed. Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Craft on Training Craft Training Program, Report be Form sure 200, to record and submit Performance the results to the results Training on Program Craft Training Sponsor. Report Certified Plus Form 200, and submit the results to the Training Program Sponsor. Credential: Trainees who successfully complete these performance s may be 2 1. Find the point where Fahrenheit equals Celsius. 2 2. Do three temperature conversions, using figures provided by your instructor. 3 3. Calculate differential pressure using values provided by your instructor. 3 4. Calculate the volume of a vessel using variables provided by your instructor. Copyright 2008 National Center for Construction Education and Research. Permission is granted to reproduce this page PROCESS MATHEMATICS MODULE 40207-08 PERFORMANCE PROFILE 7.5

Module has no Performance Profile Sheet; no performance is required for this module.

Craft: Industrial Maintenance E & I Technician Module Number: 40211-08 Module Title: Instrument Drawings and Documents, Part One Contren Learning Series Rating Levels: (1) Passed: performed (2) Failed: did not perform Also, list the date the for each was completed. Recognition: When for the NCCER Standardized Craft Training Program, be sure to record Performance results on Craft Training Report Form 200, and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 1 6 1. Locate and identify drawing elements as specified by your instructor. Copyright 2008 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENT DRAWINGS AND DOCUMENTS, PART ONE MODULE 40211-08 PERFORMANCE PROFILE 11.5

Craft: Instrumentation Module Number: 12104-01 Module Title: Electrical Systems for Instrumentation STANDARDIZED CRAFT TRAINING SERIES Rating Levels: 1. (1) Passed: performed. (2) Failed: did not perform Also, list the date the for each was completed. 2. Failed: did not perform. Recognition: When for the NCCER Standardized Craft Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Craft on Training Craft Training Program, Report be Form sure 200, to record and submit Performance the results Profile to the Training results Program on Craft Sponsor. Training Report Form 200 and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 3 1. Under the supervision of the instructor, measure and record the current, voltage, and resistance in a DC circuit. 5 2. Using any two of the measured values, calculate the power consumed by the circuit. Copyright 2001 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION LEVEL ONE MODULE 12104-01 PERFORMANCE PROFILE 4.5

Craft: Instrumentation Module Number: 12208-03 Module Title: Relays and Timers Rating Rating Levels: Levels: 1. (1) Passed: Passed: performed performed. (2) Failed: did not perform Also, list the date the for each was completed. Recognition: 2. When Failed: did for not the perform NCCER. Standardized Craft Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Training on Craft Program, Training be Report sure to record Form 200, Performance and submit the results to on the NCCER Training Training Program Report Sponsor. Form 200 Certified Plus and submit the results to the Training Program Sponsor. Credential: Trainees who successfully complete these performance s may be 2, 4, 5, 6 1. Select and install various types of relays. 9 2. Select and install various types of timers. Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION LEVEL TWO MODULE 12208-03 PERFORMANCE PROFILE 8.5

Craft: Instrumentation Module Number: 12209-03 Module Title: Switches and Photoelectric Devices Rating Levels: 1. (1) Passed: performed. (2) Failed: did not perform 2. Also, Failed: list the did date not the perform. for each was completed. Recognition: When for the NCCER Standardized Craft Training Program, Recognition: When for the NCCER Standardized Training Program, be sure to be sure to record Per for mance results on Craft Training Report record Performance results on NCCER Training Report Form 200 Form 200, and submit the results to the Training Program Sponsor. and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 1, 2, 3, 4 1. Select and install various switches. 6, 7 2. Select and install various photoelectric devices. Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION LEVEL TWO MODULE 12209-03 PERFORMANCE PROFILE 9.5

(PAGE 1 OF 2) Craft: Industrial Maintenance E & I Technician Module Number: 40209-08 Module Title: Tubing Contren Learning Series Rating Levels: (1) Passed: performed (2) Failed: did not perform Also, list the date the for each was completed. Recognition: Certified Plus Credential: When for the NCCER Standardized Craft Training Program, be sure to record Per for mance results on Craft Training Report Form 200, and submit the results to the Training Program Sponsor. Trainees who successfully complete these performance s may be 5 1. Bend copper tubing at 45-degree and 90-degree angles using a compression-type bender. 4 2. Cut and deburr copper tubing using a hacksaw or tubing cutter. 4 3. Cut and deburr stainless steel tubing. continued Copyright 2008 National Center for Construction Education and Research. Permission is granted to reproduce this page TUBING MODULE 40209-08 PERFORMANCE PROFILE 9.5

(PAGE 2 OF 2) Craft: Industrial Maintenance E & I Technician Module Number: 40209-08 Module Title: Tubing Contren Learning Series 7 4. Install a flare fitting on a section of copper tubing. 8 5. Properly make up an instrument tubing connection with a compression fitting, then loosen and re-tighten it. Copyright 2008 National Center for Construction Education and Research. Permission is granted to reproduce this page 9.6 INDUSTRIAL MAINTENANCE E & I MECHANIC LEVEL TWO MODULE 40209-08 PERFORMANCE PROFILE

Craft: Industrial Maintenance E & I Technician Module Number: 40309-09 Module Title: Layout and Installation of Tubing and Piping Systems Contren Learning Series Rating Levels: (1) Passed: performed (2) Failed: did not perform Also, list the date the for each was completed. Rating Levels: 1. Passed: performed. Recognition: When for the NCCER Standardized Craft Training Program, be 2. sure Failed: to record did not Per perform mance. results on Craft Training Report Form 200, and submit the results to the Training Program Sponsor. Recognition: When for the NCCER Standardized Craft Training Program, Certified Plus Credential: Trainees be sure to who record successfully Performance complete Profile these performance results on s Craft may Training be eligible Report for Form a Certified 200 and Plus submit Credential. the results Refer to the to the Training Note on Program Performance Spons 1 1. Given a partial system equipment location diagram (one loop) and observing all considerations covered in this module, create an isometric drawing of the given loop. 2, 3 2. Measure and bend the tubing sections in the loop and select the fittings needed to install the layout shown in the isometric drawing in Performance Task #1. 7 3. Indicate the types and locations of minimal support needed for the tubing installation. 8 4. Make up compression fittings on tubing. Copyright 2009 National Center for Construction Education and Research. Permission is granted to reproduce this page INDUSTRIAL MAINTENANCE E & I TECHNICIAN MODULE 40309-09 PERFORMANCE PROFILE 9.7

Craft: Industrial Maintenance E & I Technician Module Number: 40210-08 Module Title: Clean, Purge, and Test Tubing and Piping Systems Contren Learning Series Rating Rating Levels: Levels: (1) (1) Passed: Passed: performed performed (2) (2) Failed: Failed: did did not not perform perform Also, Also, list list the the date date the the for for each each was was completed. completed. Recognition: When for the NCCER Standardized Craft Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Craft on Training Craft Training Program, Report be Form sure 200, to record and submit Performance the results to the results Training on Program Craft Training Sponsor. Report Form 200, and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 6 1. Set up and perform a pressure leak test. 6 2. Inspect the system to verify there is no leakage. 3 3. Perform a blowdown/purge. 7 4. Document the test results and restore the system to be serviceready. Copyright 2008 National Center for Construction Education and Research. Permission is granted to reproduce this page CLEAN, PURGE, AND TEST TUBING AND PIPING SYSTEMS MODULE 40210-08 PERFORMANCE PROFILE 10.5

Craft: Industrial Maintenance E & I Technician Module Number: 40302-09 Module Title: Electronic Components Contren Learning Series Rating Rating Levels: Levels: (1) (1) Passed: Passed: performed performed (2) (2) Failed: Failed: did did not not perform perform Also, Also, list list the the date date the the for for each each was was completed. completed. Recognition: When for the NCCER Standardized Craft Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Craft on Training Craft Training Program, Report be Form sure 200, to record and submit Performance the results to the results Training on Program Craft Training Sponsor. Report Form 200, and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 6 1. Using a cross reference manual, identify a substitute for a selected electronic component. 5 2. Build a simple bridge rectifier circuit and view the results. 12 3. Check diodes. Copyright 2009 National Center for Construction Education and Research. Permission is granted to reproduce this page ELECTRONIC COMPONENTS MODULE 40302-09 PERFORMANCE PROFILE 2.3

Craft: Instrumentation Module Number: 12212-03 Module Title: Panel-Mounted Instruments Rating Levels: 1. (1) Passed: performed. (2) Failed: did not perform Also, list the date the for each was completed. 2. Failed: did not perform. Recognition: When for the NCCER Standardized Craft Training Program, Recognition: When be sure to record for the Per NCCER for mance Standardized results Training on Craft Program, Training be Report sure to record Form 200, Performance and submit the results to on the NCCER Training Training Program Report Sponsor. Form 200 and submit the results to the Training Program Sponsor. Certified Plus Credential: Trainees who successfully complete these performance s may be 2 1. Lay out an instrument panel. 3 2. Install an instrument in a panel. Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION LEVEL TWO MODULE 12212-03 PERFORMANCE PROFILE 12.3

(PAGE 1 OF 2) Craft: Instrumentation Module Number: 12213-03 Module Title: Installing Field-Mounted Instruments Rating Levels: (1) Passed: performed (2) Failed: did not perform Also, list the date the for each was completed. Recognition: Certified Plus Credential: When for the NCCER Standardized Craft Training Program, be sure to record Per for mance results on Craft Training Report Form 200, and submit the results to the Training Program Sponsor. Trainees who successfully complete these performance s may be 2 1. Fabricate a floor-mounted instrument stand. 3 2. Install an orifice plate between two flanges. 3 3. Assemble and install a thermowell assembly on a section of 4-inch process piping. continued Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION LEVEL TWO MODULE 12213-03 PERFORMANCE PROFILE 13.7

(PAGE 2 OF 2) Craft: Instrumentation Module Number: 12213-03 Module Title: Installing Field-Mounted Instruments 4 4. Identify selected pipe flange facings. 4 5. Identify selected pipe flange gaskets. 4 6. Install a three-valve manifold on a differential pressure transmitter using futbols. Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page 13.8 INSTRUMENTATION LEVEL TWO MODULE 12213-03 PERFORMANCE PROFILE

Craft: Instrumentation Module Number: 12306-03 Module Title: Grounding and Shielding of Instrumentation Wiring Rating Levels: Rating Levels: (1) Passed: performed (2) Failed: did not perform Also, 1. Passed: list the date performed the. for each was completed. Recognition: When 2. Failed: did for not the perform NCCER. Standardized Craft Training Program, be sure to record Per for mance results on Craft Training Report Recognition: When for the NCCER Standardized Training Program, be sure to Form 200, and submit the results to the Training Program Sponsor. record Performance results on NCCER Training Report Form 200 Certified Plus and submit the results to the Training Program Sponsor. Credential: Trainees who successfully complete these performance s may be 1,2 1. Identify and explain the function of an equipment ground in a given drawing. 6 2. Draw an example of a ground loop. 7 3. Identify and explain the function of an equipment shield in a given drawing. Copyright 2003 National Center for Construction Education and Research. Permission is granted to reproduce this page INSTRUMENTATION THREE MODULE 12306-03 PERFORMANCE PROFILE 6.3

Module has no Performance Profile Sheet; no performance is required for this module.