Telergon DC Isolators. for Photovoltaic applications

Similar documents
Catalogue. Surge protective devices UL range OVR NE12 and OVR T2

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

Medical Grade Power Strips

Magnetic contactor, Thermal overload relay, auxiliaries. LSISC0., Ltd. 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do Korea, Republic of

66CF1005 Certificate lifting equipment with new delivery Pag. 64/03

RS Series. Remote Manual Bypass Switch KVA, 1 PHASE KVA, 3 PHASE

MCC. SMBJP6KE6.8(C)A THRU SMBJP6KE550(C)A. Features. Transient Voltage Suppressor 6.8 to 550 Volts 600 Watt.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Criteria Booklet. Taste of the Toolbox Bali Criteria 1 Version 3 17/11/10

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME

NURSE CALLING SYSTEM

Solar Photovoltaic System

Isolette TI500 Neonatal Transport

Telehealth Beyond Videoconferencing Australian Telehealth Conference

Product Introduction. Specification Sheet. Certificates. Application. Features. Street Light

Operating Manual for HEKA Incubators

What will be covered in this NAEP workshop?

Electrical Safety and Testing Components published in Gazette Notice 1 December 2011

enflow IV fluid and blood warming system Vital Signs The right temperature, in the right place, at the right time

Medical furniture OPTIMA OBSTETRIC BED

Current-compensated Chokes EMC/EMI Chokes RN series

Lodestar. Series. Specification Sheet. Application. Features. Floodlight. Tunnel Lighting. Parking Applications. Canopy Lighting Wash Lighting.

Kimberly Shea, Administrator, Technical Projects. SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

(800) Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

CERTIFICATES OF ELECTRICAL SAFETY RESPONSIBILITY OF RECs AND ELECTRICIANS

Introduction. Welcome to Human Care.

Making a difference. Partnering with rural and regional communities towards better health. Stands for purpose

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

ELECTRICAL INSPECTION ACT CANADIAN ELECTRICAL CODE REGULATIONS

Rulemaking Hearing Rules of Department of Commerce and Insurance Division of Fire Prevention. Chapter Electrical Installations.

National Youth Science Forum (NYSF) Inspiring young Australians to futures in science since 1984

GBH 24 VFR GBH 24 VRE

DIALYSIS HOSPITAL REPORT

UK Universities Student Sensor Competition

Generator Interconnection Impact Study Report Bladen County, NC 75.0 MW Solar Farm Queue #377

Feel at home. No matter where you stay. TECHNICAL MANUAL

j. Billing procedure k. Periodical Inspections Page 1

ENTERPRISE with people in mind

Smart Energy Harvesting for Every Warfighter

RDNS and Telehealth HIC2014. Mat Tyler Project Manager Telehealth, ehealth

Generator Interconnection Facilities Study Report Franklin County, NC 50.0 MW Solar Farm Queue #384

A survey of sexually transmitted disease centres in Australia

PRICE LIST MOTORS & FANS

OFF-THE-ROAD Tires FOUNTAIN CORP

Generator Interconnection System Impact Study Report Carteret County, NC MW Queue #297 Original Submittal Revision 1

INTER POWER ENGINEERING PTE LTD

Generator Interconnection Impact Study Report Wayne County, NC 20.0 MW Solar Farm Queue #364

Approved Diploma of Nursing Programs

smart technologies Neonatal incubator from standard to intensive care

Choosing Regulatory-Compliant Power Strips for Every Area of a Healthcare Facility

Eleganza 3XC. Designed for ICU

Carbon Neutral Adelaide

A. General provisions and other electrical systems are specified in other Sections of Division 26.

1SHAFT 2BODY 3STEEL BALL 4SEAL(O-RING) 5DUST SEAL 6BALL PLUG 7SET SCREW 8GREASE NIPPLE 9PLUG (IMAGE: A-2) Ductile Cast Iron (Carbon steel in part)

Item No. Description Part No.

Approved Diploma of Nursing Programs

Distribution Statement A: Approved for public release; distribution is unlimited.

More comfortable childbirth

Adelaide 22 February Melbourne 1 March Perth 2 May Sydney 23 May Canberra 5 July

Specifications, Performance & Submittal

Buck & Boost Transformer Installation Instructions

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

smart technologies Neonatal incubator from standard to intensive care

Key to BEDSIDE External Pulse Generator Controls and Features

COMMERCIAL ITEM DESCRIPTION SHUNT, INSTRUMENT (EXTERNAL, 50 MILLIVOLT, 10 THROUGH 150 AMPERES (A) LIGHTWEIGHT TYPE)

Minutes of the Meetings held on May 1 st, 2 nd and 3 rd 2013 in Galveston - TX, US

ATTACHMENT B. 1. Intent to Bid/Bidder Contact Information Form. 2. Executive Summary. 3. Proposal Characteristics and Term Sheet

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Business plan writers brisbane. Business plan writers brisbane.zip

RG 102 Accreditation for the Inspection of Non-public High Voltage Electrical Systems

NSW Regional Health Partners. Targeted Project EOI Application Guide for MRFF 2018

Invitation to Submit Expression of Interest and Proposal

Course Outline (Winter 2017)

155 Third Generation Maritime Fire Support (155 TMF) Robert McClure BAE Systems Global Combat Systems

GENERATOR SET, SKID MOUNTED, TACTICAL QUIET

Request for Proposal Close Air Support Aircraft (A-10 Replacement)

VREDENDAL SOLAR POWER PARK (PTY) LTD.

MAXI SKY 2 THE NEXT GENERATION CEILING LIFT SOLUTION

REQUEST FOR QUALIFICATIONS EXECUTIVE ELECTRICAL ENGINEER I-5 ELECTRICAL SWITCH STATION UNIVERSITY OF CALIFORNIA, SAN DIEGO. CPM Project No.

Application for a Gold Card for Veterans of Australia s Defence Force

Security X-Ray Machine Design Proposal Crisp County Courthouse

Attitudes to Residential Asbestos Assessments

Instruction for use and trouble shooting guide

3M Infection Prevention Patient Warming Product Brochure. Warm. Every. Patient

Introduction to missiles

Australian/New Zealand Standard

MediCom. MediCom AUSTCO. State of the art Hospital Emergency Call System. The very best in nurse call and. care management solutions

Declaration of Classification ValiSpore Incubator Manual

Canada Mortgage and Housing Corporation. Jeremie LeBlanc, Consultant, Research and Information Transfer

REVEAL. Patient Assistant 9538/9539. Clinician Manual. Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Siemens Power Academy Lagos Course Schedule

Making an Informed Choice Makes a BIG Difference

AMSP Guidebook. February 2017

USMC Hybrid Power Efforts

Standard FAC Facility Ratings. A. Introduction

ARMY TM AIR FORCE TO-35C NAVY NAVFAC P

Bristol Regional Wastewater Treatment Plant Arc Flash Study Engineering Services City of Bristol Tennessee RFP 18004

Transcription:

Telergon DC Isolators for Photovoltaic applications

Photovoltaic Switches up to 1800A Telergon DC isolators are the ideal switch range for photovoltaic installations, with a high DC switching capability, Telergon isolators have been tested up to 1000V DC in accordance with IEC947.3. Features High DC switching capability Up to 1000V DC operational voltage Up to 1800A DC21B switching capability Special rotary knife contacts for improved DC arc breaking DIN profile models to suit any DIN slot Optional external handles to IP65 Models available in Hensel or W66, weatherproof enclosures

TFV5011 Switch Model DC Rated Operational voltage Ue 400V 500V 600V 800V 900V 1000V DC Rated operational current Ie (to IEC947.3) 50A 40A 25A 10A 8A 8A TFV5022 50A 50A 50A 50A 50A 40A ZFV32 32A 32A 32A 32A 32A 32A TFV5041 50A 50A 50A 50A 50A 50A S501254PR0 125A 125A 125A 125A 125A 100A S502004PR0 200A 200A 200A 180A 160A 160A S503154PR0 315A 315A 315A 280A 260A 250A S508004PC0 800A 700A 700A 630A 550A 500A S512504PC0 1250A 1250A 1250A 1000A 870A 850A S518004PS0 1800A 1800A 1800A 1500A 1350A 1250A

Spec Sheet: TFV5011 Compact non polarized isolator 50A rated up to 1000V DC. Fault-make load-break switch operation, ideal for DC systems Padlockable handle with terminals rated to IP20. DIN profile for mounting in any DIN slot. Rotary oxidation proof contacts. Up to 2 x 6mm 2 cables or 1 x 10mm 2 fork lug. Application: PV array isolators. Certification: EN 60947.3, UL 508, File E332938. Dimensions & Ratings Free air thermal current (Ith) Rated insulation voltage (Ui) Rated operational voltage (Ue) Rated impulse withstand voltage (Uimp) 50A 1500V 1000V 6kV Ambient temperature (Ith) -30 to +50 Rated Operational Current DC21B* (according to IEC 60947.3 and VDE 0660) at 400V DC at 500V DC at 600V DC at 850V DC at 1000V DC Rated Short-cct Making Capacity Short Time Withstand (1sec) 50A 40A 25A 10A 8A 1.4kA 1.0kA Short-time withstand current (1 hour) 62.5 Mechanical Endurance 30,000 Weight Operating torque 0.2kg 4Nm Connection torque 1.5 2.0Nm Cable Size mm 2 2x6 *(time constant 1ms resistive load + moderate overload) L = 65.6mm L = 65.6mm Connections 1 x MPPT Feb 2012

Spec Sheet: TFV5022 Compact non polarized isolator 50A rated up to 1000V DC. Fault-make load-break switch operation, ideal for DC systems. Padlockable handle with terminals rated to IP20. DIN profile for mounting in any DIN slot. Rotary oxidation proof contacts. Up to 2 x 6mm 2 cables or 1 x 10mm 2 fork lug. Application: PV array isolators. Certification: EN 60947.3, UL 508, File E332938. Dimensions & Ratings Free air thermal current (Ith) 50A Rated insulation voltage (Ui) 1500V Rated operational voltage (Ue) 1000V Rated impulse withstand voltage (Uimp) 6kV Ambient temperature (Ith) -30 to +50 Rated Operational Current DC21B* (according to IEC 60947.3 and VDE 0660) 1 x MPPT 2 x MPPT Rated Short-cct Making Capacity Short Time Withstand (1sec) at 400V DC 50A 50A at 500V DC 50A 40A at 600V DC 50A 25A at 800V DC 50A 10A at 900V DC 50A 8A at 1000V DC 40A 8A 1.4kA 1.0kA Short-time withstand current (1 hour) 62.5 Mechanical Endurance 30,000 Weight Operating torque Connection torque 0.24kg 4Nm 1.5 2.0Nm Cable Size mm 2 2x6 *(time constant 1ms resistive load + moderate overload) L = 77.5mm Connections 1 x MPPT 2 x MPPT Feb 2012

Spec Sheet: TFV5041 Compact non polarized isolator 50A rated up to 1000V DC. Fault-make load-break switch operation, ideal for DC systems. Padlockable handle with terminals rated to IP20. DIN profile for mounting in any DIN slot. Rotary oxidation proof contacts. Up to 2 x 6mm 2 cables or 1 x 10mm 2 fork lug. Application: PV array isolators. Certification: EN 60947.3, UL 508, File E332938. Dimensions & Ratings Free air thermal current (Ith) Rated insulation voltage (Ui) Rated operational voltage (Ue) Rated impulse withstand voltage (Uimp) 50A 1500V 1000V 6kV Ambient temperature (Ith) -30 to +50 Rated Operational Current DC21B 1) (according to IEC 60947.3 and VDE 0660) at 400V DC at 600V DC at 800V DC at 900V DC at 1000V DC Rated Short-cct Making Capacity Short Time Withstand (1sec) 50A 50A 50A 50A 50A 1.4kA 1.0kA Short-time withstand current (1 hour) 62.5 L = 142.3mm Mechanical Endurance 30,000 Weight 0.3kg Operating torque 4Nm Connection torque 1.5 2.0Nm Cable Size mm 2 2x6mm 2) 1) Time constant 1ms resistive load + moderate overload 2) For 10mm 2 cable use fork lug Connections 1 x MPPT Feb 2012

Spec Sheet: ZFV32 Compact non polarized isolator 32A rated up to 1000V DC. Fault-make load-break switch operation, ideal for DC systems. DIN profile complete with direct mounted padlockable handle. Padlockable handle with terminals rated to IP20. Oxidation proof contacts. Up to 16mm2 cable capacity. Application: PV array isolators. Certification: EN 60947.3, UL 508, File E332938. Dimensions & Ratings Free air thermal current (Ith) Rated insulation voltage (Ui) Rated operational voltage (Ue) Rated impulse withstand voltage (Uimp) Ambient temperature Open Enclosed 32A 1000V 1000V 8kV -40 to +65-40 to +65 Rated Operational Current DC21B* (according to IEC 60947.3 and VDE 0660) 1 x MPPT 2 x MPPT at 600V DC 32A 32A at 700V DC 32A 27A at 800V DC 32A 23A at 900V DC 32A 20A at 1000V DC 32A 13A Maximum Fuse (A) 80 Max padlock shank size 5mm Rated Conditional Short-cct Current 5kA Rated Sshort-cct Making Capacity Short Time Withstand (1sec) Power Loss / pole Mechanical Endurance Weight Operating torque Connection torque Cable Size mm2 1.7kA 1kA 4.0W 10,000 0.2kg 1.7Nm 1.2 1.8Nm 4-16 *(time constant 1ms resistive load + moderate overload) Connections 1 x MPPT 2 x MPPT Feb 2012

DARWIN CAIRNS BRISBANE PERTH NEWCASTLE SYDNEY WOLLONGONG ADELAIDE MELBOURNE AUCKLAND HOBART National Customer Support Centre Tel: 1300 556 601 Fax: 1300 550 187 www.ipdgroup.com.au