Plum 360 TM Infusion System with Full IV-EHR Interoperability

Similar documents
IV-EHR Interoperability

ICU Medical MedNet. Helping You Minimize IV Drug Errors And Increase Patient Safety. Safety Software

IV Interoperability: Smart Pump and BCMA Integration

Clinical Skills Validation: Alaris Pump System

End-to-end infusion safety. Safely manage infusions from order to administration

Alaris Products. Protecting patients at the point of care

Improving the Safe Use of Multiple IV Infusions

ABSTRACT. dose", all steps in the setup of the secondary infusion must be conducted correctly.

How IoT Can Improve Infusion Interoperability Clinical Workflow

HL7 v2 IEEE Passport 17M. HL7 v2 IEEE Patient SafetyNet, Radius-7 Ivenix Infusion System

Alaris System. Medication safety system focused at the point of care

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

Patient Safety and Quality Measures for CRRT: The UAB Experience. Ashita Tolwani, M.D. University of Alabama at Birmingham CRRT 2012

Staff Responsible Procedure Rationale/Reason

OHTAC Recommendation. Implementation and Use of Smart Medication Delivery Systems

Giving Intravenous (IV) Nutrition Through a Central Line with a CADD Pump

Acute Care Workflow Solutions

Raising the Bar On Infusion Safety: A Patient Safety Program at Baylor Scott & White Health Improving Infusion Pump Safety: A Systematic Approach

Hospital-wide Lean Project:

VAN WERT COUNTY HOSPITAL. Policy/Procedure: Interdepartmental No.: N Issue Date: 6-90 By: Nursing No. of Pages: 9

Considerations for Sterile Compounding of Parenteral Products for Pediatric Use: Part 2 PharMEDium Lunch and Learn Series LUNCH AND LEARN

Medication Safety Technology The Good, the Bad and the Unintended Consequences

Organizational Overview

Case Study from Parallon

Infusion Pumps: The Delivery Mechanism For Your Compounded Products PharMEDium Lunch and Learn Series

Hospira Sapphire PCA/Epidural Pump Handout

How CHRISTUS Spohn Health System uses automation to improve standardization and re-deploy pharmacists to clinical functions

One or More Errors in 67% of the IV Infusions: Insights from a Study of IV Medication Administration

Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use

INSITE : Medication Management for Long-Term Care

Safety Innovations FOUNDATIONHTSI. Nine Recommendations To Prevent Multiple Line Infusion Medication Errors

To describe the process for the management of an infusion pump involved in an adverse event or close call.

Profiles in CSP Insourcing: Tufts Medical Center

Driving Business Value for Healthcare Through Unified Communications

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

Safe Medication Practices

Optum Anesthesia. Completely integrated anesthesia information management system

HL7 v2 IEEE and DoseLink. HIMSS Interoperability Showcase Page 1 of 11

SPOK MESSENGER. Improving Staff Efficiency and Patient Care With Timely Communications and Critical Connectivity

Optimizing Patient Outcomes

Increasing security and convenience at Epic health systems

RescueNet Dispatch, epcr, Care Exchange. HL7 v2. Ellkay LK EMR-Archive Smart on FHIR SAML Ellkay to Epic

Objectives. Demographics: Type and Services 1/22/2014. ICAHN Aggregate Results. ISMP Medication Safety Self Assessment for Hospitals

How Pharmacy Informatics and Technology are Evolving to Improve Patient Care

with the team that understands your drug delivery needs. Comprehensive solutions in drug delivery.

Medication Safety Way Beyond the 5 Rights

Masimo Patient SafetyNet

About Humanscale Healthcare

Smart Pumps and Drug Libraries The Way Forward

TELLIGENCE. Workflow Solutions. Integrated Workflow Intelligence. Ascom

Medicine Reconciliation FREQUENTLY ASKED QUESTIONS NATIONAL MEDICATION SAFETY PROGRAMME

How BPOC Reduces Bedside Medication Errors White Paper

Nurse Call Communication System

Improving patient safety and infection. Patient Safety Forum Dr J Coleman 1 ELECTRONIC PRESCRIBING AND CLINICAL DECISION SUPPORT (CDS)

HealthMatics ED Emergency Department Information System

The future of patient care. 6 ways workflow automation will transform the healthcare experience

EHR Implementation Best Practices. EHR White Paper

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

PROCESS FOR HANDLING ELASTOMERIC PAIN RELIEF BALLS (ON-Q PAINBUSTER AND OTHERS)

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

SAFE Standard of Care

How can oncology practices deliver better care? It starts with staying connected.

Medication Safety & Electrolyte Administration. Objectives. High Alert Medications. *Med Safety Electrolyte Administration

Infusion Pumps: a structured approach to drug library optimization

Streamlining Medical Image Sharing For Continuity of Care

NCPDP Work Group 11 Task Group: RxFill White Paper on Implementation Issues

HL7 v2 IEEE OBIX Perinatal Data System

Automation and Information Technology

Top Ten Health Technology Hazards

D Bringing you closer to your patients PATIENT MONITORING AND IT SOLUTIONS

The anesthesiologist switches the patient from the ventilator to the cardiopulmonary

STANDARDIZED PROCEDURE HEPATIC ARTERY INFUSION OF CHEMOTHERAPY (Adults, Peds)

Go! Guide: Medication Administration

Optimizing Medication Distribution using Automated Dispensing Cabinets

Adverse Drug Events: A Focus on Anticoagulation Steve Meisel, Pharm.D., CPPS Director of Patient Safety Fairview Health Services, Minneapolis, MN

Keenan Pharmacy Care Management (KPCM)

UPMC PASSAVANT Policy Manual. TITLE/SUBJECT: IntraOsseous Device POLICY NO:

Department Policy. Code: D: MM Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

Constant Pursuit of Medication Safety. Geraldine Koh Chief Pharmacist

An EHR Overview for Pharma Marketers

A Case Study in Collaboration: The Delaware Cancer Treatment Task Force. Jerry Ewancio, RPh, Director of Pharmacy, Apple Infusion, Salisbury, MD

Smart Pump Interoperability: A Multi-System Safety Journey. February 23, 2018

Drug Distribution Services for Long Term Care Facilities. Susan L. Lakey, PharmD 1/11/06

To establish a consistent process for the activity of an independent double-check prior to medication administration, where appropriate.

Conflict of Interest. Objectives. The Solution. The Need. Reaching for the Stars Advanced Roles for Pharmacy Technicians.

Seamless Clinical Data Integration

Building a Smarter Healthcare System The IE s Role. Kristin H. Goin Service Consultant Children s Healthcare of Atlanta

Preventing Medical Errors

Presenters. Technology Interoperability at the Bedside. Learning Objectives. Learning Objectives 8/30/2012. Wednesday, October 3, :15 5:15 pm

Evidence-Based Practices to Optimize Prescriber Use of PDMPs

Continuous Monitoring of Patients on Opioids: Capnography Initiative at BJC Healthcare. Friday October 14, 2016

MBCHD and CARS Use myavatar EHR to Facilitate Care for 6,000 Patients

The Connected Point of Care Ecosystem: A Solid Foundation for Value-Based Care

Monitoring in ICU. BR Bhengu UKZN

DISCIPLINE COMMITTEE OF THE COLLEGE OF NURSES OF ONTARIO. PANEL: Joanne Furletti, RN Chairperson Rosalie Woods, RPN Member

Intelligence. Intelligence. Workload forecasting with Cerner Clairvia. Workload forecasting with Cerner Clairvia

IMPACT OF TECHNOLOGY ON MEDICATION SAFETY

The birth of a new era Excellent neonatal respiratory support at your fingertips DRÄGER BABYLOG VN500

REVISED FIP BASEL STATEMENTS ON THE FUTURE OF HOSPITAL PHARMACY

Transcription:

Plum 360 TM Infusion System with Full IV-EHR Interoperability Your Direct Connection To Clinical Excellence > Air management that doesn t require disconnecting from the patient > A secondary line that connects directly to the cassette > Proven full IV-EHR interoperability, ready when you are

Get the Clinical Performance and Full IV-EHR Interoperability You Need Today With today s hectic pace, tight budgets, and patient safety concerns, you need an infusion pump that serves you and your patients, helping to maximize valuable resources and enhance your clinical practice. Achieving clinical excellence takes a pump that enables it. With ICU Medical s Plum 360 infusion system, you re equipped to do your best. With air management that doesn t require disconnecting from the patient, a secondary line that connects directly to the cassette, and proven full IV-EHR interoperability, you ll find that this infusion pump is unlike any other. Maximize Safety with Closed System Air Management * The unique design of the PlumSet cassette allows for automated backpriming to easily remove air from the line without disconnecting from the patient, allowing you to maintain a closed system.* Reduce Therapy Interruptions Capture 1 ml of air in the cassette s air trap an industry exclusive feature before the alarm is activated. Reduce Risk of Contamination Help eliminate the potential for contaminants by keeping the patient line connected. Limit Exposure to Hazardous Medications Protect clinicians and prepare for USP <800> with the PlumSet cassette s closed system.* Minimize Wasted Medication No need to purge the distal line, because air is removed without disconnecting from the patient, minimizing wasted medication. * When using the PlumSet with Clave secondary port and a closed system transfer device.

See Why Secondary Delivery Is of Primary Importance ICU Medical s Plum 360 infusion system is unique in the way it connects the secondary line directly to the PlumSet cassette so the pump can differentiate between primary and secondary infusion lines and deliver each as intended. And if your secondary line is not infusing, an alarm will alert you. The results? You re more likely to reduce medication errors and ensure proper delivery. Deliver Medication as Intended The direct-connect secondary delivery helps to ensure medication is administered as intended, helping to improve delivery accuracy and avoid infusion errors. Lower Medication Errors, Not Infusion Containers Plum 360 functions independent of head height. And the direct connection helps to reduce the risk of infusing the primary medication at the secondary rate. Believe in Your Data With direct-connect secondary delivery, you can feel confident that the prescribed infusion is delivered and your patient infusion data accurately reflects the infusion. Do Two Things at Once Simultaneously deliver two compatible medications at independent rates through a single line something only ICU Medical s Plum 360 infusion systems can do.

Optimize Compliance and Enhance Safety by Automatically Starting in the Drug Library When programming your Plum 360 infusion system with ICU Medical MedNet software, you automatically start in the drug library. This helps to ensure that the hard and soft limits in the drug library are utilized, greatly improving compliance and enhancing medication safety for your patients. Large drug library The extensive drug library includes 2500 medications (medications used in multiple CCAs count as a single entry), 40 CCAs, and 400 medications per CCA, giving you the flexibility to tailor your drug library as needed. Clinical use selection Multiple limits, based on clinical usage, can be defined for a given medication, allowing further refinement of the infusion parameters. Extensive dosing units The Plum 360 helps you administer the medication orders the way it was written with 119 dosing units. Sample of initial programming screens A B A Critical Care (1 of 10) A Critical Care (1 of 1) A Clinical Use Change CCA Sort: DOP DOPamine 0 Rate 0 0 ml/hr Vol Inf ml 0 Maintenance Fluid 1000mL Maintenance Fluid 500mL 0.9% NS 1000mL Amiodarone 450mg/250mL Amiodarone Bolus 150mg/100mL DOBUT amine 500mg/250mL DOBUT amine DS 1000mg/250mL DOPamine DOPamine DS 400mg/250mL 800mg/250mL Conc 400mg 250mL CARDIAC RENAL TRANSPLANT Critical Care Select Line A/B to Program Select Choose to Change CCA Press 0-9 to Sort this list Press [C] key to clear sorting. Select then press Choose. Select then press Choose. Back Prime A B Settings/ Vols/CCA Page Up Page Down Choose Previous Screen Choose Previous Screen Choose Previous Screen Select Line (A) Enter Alphanumeric Keys for Desired Drug Select Drug Choose Clinical Use For further refinement, more specific limits can be implemented by selecting clinical uses (up to four per medication).

EHR Ready, Today and Tomorrow When you and your electronic health record (EHR) partner are ready for integration, your Plum 360 infusion system with ICU Medical MedNet safety software is ready, too. Whether it s today, or any time after, ICU Medical s full IV-EHR interoperability lets you connect your Plum 360 system to the IV medication order and patient information from the EHR. Enhance patient safety and clinician workflow Bypass drug errors and manual steps by automatically populating your Plum 360 pumps with medication orders sent directly from your EHR medication administration workflow. 1 Reduce Manual Steps Scan the Patient > Smart pump programming that extends the benefits of integration beyond the initial infusion set up to include just about everything you do for infusion management but in an integrated environment (new bag, rate change, titration, medications not in the drug library, and changes to the care area without needing to stop or restart the pump). 2 Scan the Medication > Infusion documentation that captures pump settings, start and stop times, and titrations including accurate documentation of secondary infusions. 3 Scan the Pump Channel > Alarm-forwarding capabilities to help improve alarm monitoring and responses. Ready to work with you Our IV-EHR solution is compatible with 67% of the EHR market with continuous development underway to further extend our reach. 1 Real results from clinical sites* > Reduced manual steps from 17 to 7 2 4 Verify Settings & Start Infusion > 32% reduction in monthly IV heparin errors reported from telemetry and med-surg care areas 3 > Reduced time to document a code blue from 120 to 5 minutes 2 5 Complete Documentation * Results from live IV Clinical Integration sites. Pump type may vary. Results may vary by facility.

Featuring Built-in Safety and Efficiency The Plum 360 was designed with safety and efficiency in mind. In addition to air management that doesn t require disconnecting from the patient, a secondary line that connects directly to the cassette, and proven full IV-EHR interoperability, Plum 360 has a number of innovative features designed to help you enhance patient safety and increase clinical efficiency, including: > Bolus delivery capability to facilitate rapid infusion to magnify therapeutic response > Integrated free-flow protection built into PlumSet cassette technology > Automated concurrent and piggyback delivery > Proximal tubing guides to help clearly identify and organize secondary lines > Distal occlusion auto restart - Clears alarm and automatically restarts the pump if a distal occlusion has been quickly resolved > Enhanced cybersecurity that is FIPS 140-2 validated Our Training and Support Helps Nurture Your Success With ICU Medical, you have a partner with the expertise of more than 500,000 pumps installed worldwide and the dedicated resources to help ensure your implementation is a success and you are performing at your optimum. Some of the many ways we can help you succeed are through: > Operational expertise Program managers and information systems specialists help assemble your implementation plan, assess the environment for wireless connectivity, configure devices, and optimize your drug library. > Extensive support An interdisciplinary team of pharmacists, nurses, and IT professionals help train your staff and provide service and support for the system. > Ongoing innovation A commitment to investing in the Plum 360 system so that, as your needs grow and change, we adapt to meet them, protecting your investment over the long term.

Rx List RxA RxB RxC RxD Straight Talk: How a Direct Connection Helps Streamline Secondary Delivery A direct connection from the secondary line to cassette reduces risk and increases efficiency Take a look at the infusion scenario below, both with and without the Plum cassette, to find out. Without Plum Cassette With Plum Cassette Hang secondary bag and lower the primary bag. Hang secondary bag. Since it does not rely on fluid dynamics, it is not necessary to lower the primary bag. Connect the secondary line to the primary line above the infusion pump. Connect the secondary line directly to the Plum cassette. Program and start the secondary infusion. Program and start the secondary infusion. Nurse is pulled from the patient s room for an emergency and leaves without opening the clamp on the secondary line. Nurse is pulled from the patient s room for an emergency and leaves without opening the clamp on the secondary line. The pump delivers the primary medication at the secondary rate. The secondary medication is not being delivered and no alarm is triggered. Proximal Occlusion The pump alarm sounds, alerting the nurse to the station. The nurse clears the alarm, opens the clamp, and starts the secondary infusion. Choose the Plum 360 infusion system your direct connection to clinical excellence.

Your Mission is Clinical Excellence. The Plum 360 is Your Direct Connection. For more information, visit www.icumed.com or call (877) 946-7747 to speak to a sales representative. Only. For safe and proper use of this device, please refer to the appropriate manual. 1. Vaidya A, Epic, Cerner hold 50% of hospital EHR market share: 8 things to know [web page]. Created August 2, 2017. Available at http://www.beckershospitalreview.com/healthcare-information-technology/epic-cerner-hold-50-of-hospital-ehr-market-share-8- things-to-know.html. Accessed August 3, 2017. 2. Prusch AE, Suess TM, Paoletti RD, et al. Integrating technology to improve medication administration. Am J Health Syst Pharm. 2011;68(9):835-842. 3. Cerner Corporation. Closing the loop in IV medication administration [white paper]. Kansas City, MO: Cerner Corporation; 2011. 2017 ICU Medical Inc. P14-0331-2-R2-Jul., 17 800.824.7890 www.icumed.com