INTERNATIONAL STANDARD

Similar documents
ISO/TR TECHNICAL REPORT. Business requirements for health summary records Part 2: Environmental scan

ISO INTERNATIONAL STANDARD. Medical laboratories Requirements for safety. Laboratoires de médecine Exigences pour la sécurité

NZS/ISO 15189:2007. Medical Laboratories Particular Requirements for Quality and Competence NZS/ISO 15189:2007

This document is a preview generated by EVS

Packaging for terminally sterilized medical devices - Guidance on the application of ISO and ISO (ISO 16775:2014)

This document is a preview generated by EVS

IECEE OPERATIONAL DOCUMENT

REQUIREMENTS FOR FACTORY INSPECTORS

Form 4: New Work Item Proposal. Reference number: ISO/NP Circulation date: (to be given by Central Secretariat)

IECEx OPERATIONAL DOCUMENT

Content Sheet 11-1: Overview of Norms and Accreditation

Department of Defense INSTRUCTION. 1. PURPOSE. In accordance with the authority in DoD Directive (DoDD) (Reference (a)), this Instruction:

Australian Standard. Clinical investigations of medical devices for human subjects. Part 1: General requirements AS ISO ISO :2003

New work item proposal Outsourcing

ISO/TC 59/SC 13 N 526

Safety EMC Environment Quality assurance

Working document QAS/ RESTRICTED September 2006

TC 100 Guidelines and Procedures

CMDCAS Handbook Policies and Procedures for Sector Qualification under the Canadian Medical Devices Conformity Assessment System (CMDCAS)

Medical Device and Health Software

PATHWAYS FOR STANDARDS DEVELOPMENT. Developing internationally aligned Australian Standards in the national interest

Simultaneous circulation to CEN and CENELEC TECHNICAL BOARDS

Australian/New Zealand Standard

Which QMS Standard should be chosen for the structural quality of a medical laboratory? Matthias ORTH

International Perspectives. Marjorie S. Greenberg, MA National Center for Health Statistics Centers for Disease Control and Prevention

SA/SNZ HB 205:2017. Handbook. Managing health-and-safetyrelated SA/SNZ HB 205:2017

Klinisk prövning av medicintekniska produkter Del 2: Kliniska prövningsplaner (ISO :2003)

Standards and Research : a key issue for

IEC-IEEE development of dual logo standards on condition monitoring Update November Kjell Spång KS miltek

AS/NZS :2014. Single-use medical examination gloves AS/NZS :2014

Linking research and standardization. Integrating standards in your research project: a pocket guide for project proposers

ISO/IEC JTC1/SC7 /N3020

IAF Mandatory Document for the Application of ISO/IEC in Medical Device Quality Management Systems (ISO 13485)

AS/NZS 1336:1997 AS/NZS

Call for Experts representing the SME perspective

Miscellaneous Publication

National clinical audit of inpatient care for adults with ulcerative colitis

FOOD SAFETY SYSTEM CERTIFICATION Part I: Scheme Overview

SOUTH AFRICAN NATIONAL STANDARD

IAF MLA Document. Policies and Procedures for a MLA on the Level of Single Accreditation Bodies and on the Level of Regional Accreditation Groups

IAF Liaison Report to CIML November 2014

004 Licensing of Evaluation Facilities

The route to signing the IAF/ILAC Arrangement. Good Practice Guidelines for Single Accreditation Bodies

Open call for Experts to

ISO Registration Bodies Governance ISO RMG Rules Sub-group Approved on 14 April 2017

Jim Matthews III Vice-President Chairman, SMB. ANSI Smart Sustainable Cities 21 November 2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION

Policy Category: Activity Policy. Policy Name: QCHP CPD Activity Accreditation Eligibility Policy. Policy Code: MOPH/QCHP/AD/CPDActivities/001

IAF Guidance on the Application of ISO/IEC Guide 61:1996

Jim Moore IEEE Computer Society Liaison Representative to ISO/IEC JTC 1/SC 7 Annual Report for Standards Activities Board Oct 2013

TITLE: IECEx Surveillance report for Korea Gas Safety Corporation (KGS) an accepted ExCB including an extension to scope INTRODUCTION

S ince its incorporation in January 1992, Clinical

Building blocks of health information: Classifications, terminologies, standards

Australian/New Zealand Standard

Interim Australian/New Zealand Standard

Introduction Patient-Centered Outcomes Research Institute (PCORI)

Experience of inpatients with ulcerative colitis throughout

PRACTICAL APPLICATION OF ISO BY ACCREDITATION BODIES - A comparison with ISO/IEC Page 128. ejifcc2004vol15no4pp

The CMMI Product Suite and International Standards

Level 2 Award in. Allergen Awareness. Qualification Specification. Qualification Recognition Number: 603/2833/2. ABBE Qualification Code: AwardAAL217

Meeting at BIPM, Paris Friday 15 June 2012 at 9: 00 till 13:00 Lunch: 13:00. NMI TC Representatives KEBS Mr Anderson Maina

Australian/New Zealand Standard

NEW PROJECT PROPOSAL FORM

National Disability Insurance Scheme (Approved Quality Auditors Scheme) Guidelines 2018

ISO Helmut Reihlen 2010 Award Can International Standards help fight climate change?

IEC 2010 Seattle, USA Sponsorship Opportunities. IEC 2010 Into the Future

Australian/New Zealand Standard

IEEE Standards Association

IMAS Second Edition 01 October 2008 Amendment 4, June 2013

Practice Guidelines for Medication Practices

Raad voor Accreditatie (Dutch Accreditation Council RvA) Specific Accreditation Protocol for Certification according to ISO/IEC 13485

Standardization Activities of SMIIC Technical Committees (TCs)

Building and strengthening national health research systems

Australian/New Zealand Standard

DMTF Standards Incubation Process

Nurse-to-Patient Ratios

Guidelines: Postdoc.Mobility return grants

Accreditation Procedure

The CLSI Consensus Process: Making a Difference in Health Care David Sterry, MT(ASCP) Director, Standards Development, CLSI

WORKPLACE VIOLENCE IN THE HEALTH SECTOR COUNTRY CASE STUDIES RESEARCH INSTRUMENTS RESEARCH PROTOCOL. Joint Programme on

DG(SANCO)/ MR

Networked Medical Devices And The IEC80001 Standard: Are You Ready?

INTERQUAL REHABILITATION CRITERIA REVIEW PROCESS

A checklist for carers. Information leaflet

Train The Trainer Course on Regional Minimum Standards For National Reference Laboratories

IEEE P802.3ba 40Gb/s and 100Gb/s Ethernet

Terminology in Healthcare and

Our Lady s Children s Hospital

GPP Subcommittee Meeting

Practical application of ISO by accreditation bodies A comparison with ISO/IEC 17025

Successful disease management requires technology that can measure progress, show gaps

general criteria New Zealand Code of Radiology Management Practice for accreditation

CLEAN DEVELOPMENT MECHANISM PROJECT DESIGN DOCUMENT FORM (CDM-PDD) Version 03 - in effect as of: 28 July 2006 CONTENTS

UPDATE OF QUALITY ASSURANCE HANDBOOK

REPORT. Unit # 1, Street Surrey, British Columbia, V3W 4E6, Canada

CEN Technical Committees Mode of operations

Medical Supply Co. Ltd.

icare's Clinical, Care & Medication Management Solution

World Health Organization (WHO)

QUASER The Hospital Guide. A research-based tool to reflect on and develop your quality improvement strategies Version 2 (October 2014)

Transcription:

INTERNATIONAL STANDARD ISO 13379-1 First edition 2012-05-01 Condition monitoring and diagnostics of machines Data interpretation and diagnostics techniques Part 1: General guidelines Surveillance et diagnostic d état des machines Interprétation des données et techniques de diagnostic Partie 1: Lignes directrices générales Reference number ISO 13379-1:2012(E) ISO 2012

ISO 2012 COPYRIGHT PROTECTED DOCUMENT All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO s member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2012 All rights reserved

Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Normative references... 1 3 Terms and definitions... 1 4 Condition monitoring set-up and diagnostics requirements... 1 4.1 Role of diagnostics in operation and maintenance... 1 4.2 Establishing diagnostics needs... 1 4.3 Failure mode symptoms analysis... 2 4.4 Diagnostics requirements report... 6 5 Elements used for diagnostics... 6 5.1 Condition monitoring data... 6 5.2 Machine data... 8 5.3 Machine history... 8 6 Diagnostic approaches... 9 6.1 Two types of approaches... 9 6.2 General guidelines for the selection of appropriate diagnostic approaches... 9 6.3 Data-driven approaches...10 6.4 Knowledge-based approaches...14 6.5 Confidence factor determination...18 Annex A (informative) Failure mode and symptoms analysis (FMSA)...20 Annex B (informative) Effectiveness of the diagnostics system...23 Annex C (informative) Comparative analysis of diagnostic models...25 Annex D (informative) Most commonly used diagnostic models by monitoring technique... 26 Annex E (informative) Example of diagnostic report...27 Annex F (informative) Example of causal tree modelling: bearing spalling... 30 Annex G (informative) Example of diagnosis confidence level determination... 32 Bibliography...33 ISO 2012 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13379-1 was prepared by Technical Committee ISO/TC 108, Mechanical vibration, shock and condition monitoring, Subcommittee SC 5, Condition monitoring and diagnostics of machines. This first edition of ISO 13379-1 cancels and replaces ISO 13379:2003, which has been technically revised. ISO 13379 consists of the following parts, under the general title Condition monitoring and diagnostics of machines Data interpretation and diagnostics techniques: Part 1: General guidelines The following parts are planned: Part 2: Data-driven applications Part 3: Knowledge-based applications iv ISO 2012 All rights reserved

Introduction ISO 13379-1:2012(E) This part of ISO 13379 contains general procedures that can be used to determine the condition of a machine relative to a set of baseline parameters. Changes from the baseline values and comparison to alarm criteria are used to indicate anomalous behaviour and to generate alarms: this is usually designated as condition monitoring. Additionally, procedures that identify the cause(s) of the anomalous behaviour are given in order to assist in the determination of the proper corrective action: this is usually designated as diagnostics. ISO 2012 All rights reserved v

ISO 2012 COPYRIGHT PROTECTED DOCUMENT All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO s member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2012 All rights reserved

Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Normative references... 1 3 Terms and definitions... 1 4 Condition monitoring set-up and diagnostics requirements... 1 4.1 Role of diagnostics in operation and maintenance... 1 4.2 Establishing diagnostics needs... 1 4.3 Failure mode symptoms analysis... 2 4.4 Diagnostics requirements report... 6 5 Elements used for diagnostics... 6 5.1 Condition monitoring data... 6 5.2 Machine data... 8 5.3 Machine history... 8 6 Diagnostic approaches... 9 6.1 Two types of approaches... 9 6.2 General guidelines for the selection of appropriate diagnostic approaches... 9 6.3 Data-driven approaches...10 6.4 Knowledge-based approaches...14 6.5 Confidence factor determination...18 Annex A (informative) Failure mode and symptoms analysis (FMSA)...20 Annex B (informative) Effectiveness of the diagnostics system...23 Annex C (informative) Comparative analysis of diagnostic models...25 Annex D (informative) Most commonly used diagnostic models by monitoring technique... 26 Annex E (informative) Example of diagnostic report...27 Annex F (informative) Example of causal tree modelling: bearing spalling... 30 Annex G (informative) Example of diagnosis confidence level determination... 32 Bibliography...33 ISO 2012 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13379-1 was prepared by Technical Committee ISO/TC 108, Mechanical vibration, shock and condition monitoring, Subcommittee SC 5, Condition monitoring and diagnostics of machines. This first edition of ISO 13379-1 cancels and replaces ISO 13379:2003, which has been technically revised. ISO 13379 consists of the following parts, under the general title Condition monitoring and diagnostics of machines Data interpretation and diagnostics techniques: Part 1: General guidelines The following parts are planned: Part 2: Data-driven applications Part 3: Knowledge-based applications iv ISO 2012 All rights reserved

Introduction ISO 13379-1:2012(E) This part of ISO 13379 contains general procedures that can be used to determine the condition of a machine relative to a set of baseline parameters. Changes from the baseline values and comparison to alarm criteria are used to indicate anomalous behaviour and to generate alarms: this is usually designated as condition monitoring. Additionally, procedures that identify the cause(s) of the anomalous behaviour are given in order to assist in the determination of the proper corrective action: this is usually designated as diagnostics. ISO 2012 All rights reserved v

ISO 2012 COPYRIGHT PROTECTED DOCUMENT All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO s member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2012 All rights reserved

Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Normative references... 1 3 Terms and definitions... 1 4 Condition monitoring set-up and diagnostics requirements... 1 4.1 Role of diagnostics in operation and maintenance... 1 4.2 Establishing diagnostics needs... 1 4.3 Failure mode symptoms analysis... 2 4.4 Diagnostics requirements report... 6 5 Elements used for diagnostics... 6 5.1 Condition monitoring data... 6 5.2 Machine data... 8 5.3 Machine history... 8 6 Diagnostic approaches... 9 6.1 Two types of approaches... 9 6.2 General guidelines for the selection of appropriate diagnostic approaches... 9 6.3 Data-driven approaches...10 6.4 Knowledge-based approaches...14 6.5 Confidence factor determination...18 Annex A (informative) Failure mode and symptoms analysis (FMSA)...20 Annex B (informative) Effectiveness of the diagnostics system...23 Annex C (informative) Comparative analysis of diagnostic models...25 Annex D (informative) Most commonly used diagnostic models by monitoring technique... 26 Annex E (informative) Example of diagnostic report...27 Annex F (informative) Example of causal tree modelling: bearing spalling... 30 Annex G (informative) Example of diagnosis confidence level determination... 32 Bibliography...33 ISO 2012 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13379-1 was prepared by Technical Committee ISO/TC 108, Mechanical vibration, shock and condition monitoring, Subcommittee SC 5, Condition monitoring and diagnostics of machines. This first edition of ISO 13379-1 cancels and replaces ISO 13379:2003, which has been technically revised. ISO 13379 consists of the following parts, under the general title Condition monitoring and diagnostics of machines Data interpretation and diagnostics techniques: Part 1: General guidelines The following parts are planned: Part 2: Data-driven applications Part 3: Knowledge-based applications iv ISO 2012 All rights reserved

Introduction ISO 13379-1:2012(E) This part of ISO 13379 contains general procedures that can be used to determine the condition of a machine relative to a set of baseline parameters. Changes from the baseline values and comparison to alarm criteria are used to indicate anomalous behaviour and to generate alarms: this is usually designated as condition monitoring. Additionally, procedures that identify the cause(s) of the anomalous behaviour are given in order to assist in the determination of the proper corrective action: this is usually designated as diagnostics. ISO 2012 All rights reserved v

ISO 2012 COPYRIGHT PROTECTED DOCUMENT All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO s member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2012 All rights reserved

Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Normative references... 1 3 Terms and definitions... 1 4 Condition monitoring set-up and diagnostics requirements... 1 4.1 Role of diagnostics in operation and maintenance... 1 4.2 Establishing diagnostics needs... 1 4.3 Failure mode symptoms analysis... 2 4.4 Diagnostics requirements report... 6 5 Elements used for diagnostics... 6 5.1 Condition monitoring data... 6 5.2 Machine data... 8 5.3 Machine history... 8 6 Diagnostic approaches... 9 6.1 Two types of approaches... 9 6.2 General guidelines for the selection of appropriate diagnostic approaches... 9 6.3 Data-driven approaches...10 6.4 Knowledge-based approaches...14 6.5 Confidence factor determination...18 Annex A (informative) Failure mode and symptoms analysis (FMSA)...20 Annex B (informative) Effectiveness of the diagnostics system...23 Annex C (informative) Comparative analysis of diagnostic models...25 Annex D (informative) Most commonly used diagnostic models by monitoring technique... 26 Annex E (informative) Example of diagnostic report...27 Annex F (informative) Example of causal tree modelling: bearing spalling... 30 Annex G (informative) Example of diagnosis confidence level determination... 32 Bibliography...33 ISO 2012 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13379-1 was prepared by Technical Committee ISO/TC 108, Mechanical vibration, shock and condition monitoring, Subcommittee SC 5, Condition monitoring and diagnostics of machines. This first edition of ISO 13379-1 cancels and replaces ISO 13379:2003, which has been technically revised. ISO 13379 consists of the following parts, under the general title Condition monitoring and diagnostics of machines Data interpretation and diagnostics techniques: Part 1: General guidelines The following parts are planned: Part 2: Data-driven applications Part 3: Knowledge-based applications iv ISO 2012 All rights reserved

Introduction ISO 13379-1:2012(E) This part of ISO 13379 contains general procedures that can be used to determine the condition of a machine relative to a set of baseline parameters. Changes from the baseline values and comparison to alarm criteria are used to indicate anomalous behaviour and to generate alarms: this is usually designated as condition monitoring. Additionally, procedures that identify the cause(s) of the anomalous behaviour are given in order to assist in the determination of the proper corrective action: this is usually designated as diagnostics. ISO 2012 All rights reserved v