ES-301 Administrative Topics Outline Form ES-301-1

Similar documents
Outage dates (duration): September 5, 1996 to May 27, 1999 (2.7 years) Reactor age when outage began: 8.8 years

NATIONAL NUCLEAR REGULATOR

NEI [Revision 0] Guidelines for a Certified Fuel Handler Training and Retraining Program

Subj: CHANGE OR EXCHANGE OF COMMAND OF NUCLEAR POWERED SHIPS. Encl: (1) Engineering Department Change of Command Inspection List

CNSC Type I Inspections of Activities and Devices for Nuclear Substances and Radiation Device Licensees Group 3.5 Licensees

Brachytherapy-Radiopharmaceutical Therapy Quality Management Program. Rev Date: Feb

NRC INSPECTION MANUAL

IGO GROUP SAFETY STANDARD 15 - ENERGY CONTROL AND ISOLATION INDEPENDENCE GROUP NL

631-jx. Davis Besse Power Station Transmittal / Receipt Acknowledgement

Site Access and Identification Badges

REACTOR OPERATIONS AT SAFARI-1. JWH Vlok 1 Manager: Reactor Operations SAFARI-1 Research Reactor NECSA South Africa ABSTRACT

Swedish Radiation Safety Authority Regulatory Code

Staging Board Procedures. Supersedes: 8/27/01 (New) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

BHG Operational Awareness Program May 8, 1998 Surveillance Guideline OPS-9.12 Revision 0 Operations Turnover Page 1 of 8 OPERATIONS TURNOVER

Regulatory Guide 8.7 Instructions for Recording and Reporting Occupational Radiation Exposure Data

NRC REGULATORY ISSUE SUMMARY CONTROL OF RADIATION DOSE TO VISITORS OF HOSPITAL PATIENTS

Incident Reporting, Notification, and Review Procedure

May 23, Docket No License No. DPR-12

Western Michigan University. Training Program

120 White Bridge Rd. Nashville, TN Control of Hazardous Energy Program OSHA (lockout/ Tagout) standard 29 CFR

University of Maryland Baltimore. Radiation Safety Procedure

General Health and Safety Information for Victoria University. An outline of any further Health and Safety Training you may require.

Medical Event Reporting

Site Description. CCR Rule (a)(3), Emergency Action Plan (EAP)

Summary Report for Individual Task TROUBLESHOOT THE AVIATION GROUND POWER UNIT (AGPU) Status: Approved

Incident Command System Awareness Participant Guide May 2016

NORTH CAROLINA A&T STATE UNIVERSITY Chemical Hygiene Plan

February 8, 2017 SUBJECT: GRAND GULF NUCLEAR STATION - NRC INTEGRATED INSPECTION REPORT /

CORK COUNTY COUNCIL SANITARY CARETAKER GRADE 5 WATER SERVICES ZONE 3 (SOUTH EAST)

EXTRAORDINARY PUBLISHED BY AUTHORITY. ISLAMABAD, THURSDAY, March 1, 2012

DOE N /29/95 Expires: [1 year after initiation]

Summary Report for Individual Task M-3335 Supervise Driver's Training Program Status: Approved

JEFFERSON LAB Radiological Work Permit

FENOC AOLVS. February 3, 2000 PY-CEI/NRR-2463L. United States Nuclear Regulatory Commission Document Control Desk Washington, D. C.

Emergency Operations Plan

105 CMR: DEPARTMENT OF PUBLIC HEALTH

City of Hays Request for Proposal. Wastewater Treatment Plant Fiber Connectivity

Mobile Positron Emission Tomography

NUCLEAR POWER PLANT EMERGENCY PREPAREDNESS

805C-LF Report Suspected Postal Incidents Status: Approved

Radiation Protection Procedures for the Cincinnati Proton Therapy Center (CPTC)

INFORMAL SAFETY PROGRAM FOR SMALL BUSINESS

Policy on Minors in Laboratories

Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

1. General. 2. Background

Revision #: 0 Prepared By: Beth Eckert, Industrial Chemist Revision Date: 1/10/00 Approved By: Larry Cummings, Asst. Superintendent of WWTD

HAZARDOUS MATERIAL (HAZMAT) INCIDENTS

Sample orientation checklist

INCIDENT COMMANDER. Date: Start: End: Position Assigned to: Signature: Initial: Hospital Command Center (HCC) Location: Telephone:

SUBJECT: Radioactive Material Licensing POLICY 6-3

EMERGENCY MANAGEMENT TEAM

A. General provisions and other electrical systems are specified in other Sections of Division 26.

Summary Report for Individual Task 805C-LF Prepare Daily Money Order Business Report Status: Approved

VAMC Radiation Safety Refresher Training March 2011

Department of Defense INSTRUCTION

MEDICAL-TECHNICAL SPECIALIST: BIOLOGICAL/INFECTIOUS DISEASE

Electrical Safety and Testing Components published in Gazette Notice 1 December 2011

Section I Referenced Publications. ANSI/IES-RP American National Standards Institute and Illuminating Engineering Society standard

MSE CONTROLLED DOCUMENT. NORM Training

EvCC Emergency Management Plan ANNEX #02 Emergency Operations Center

Peninsula Dental Social Enterprise (PDSE)

Operational Experience Log Book

COMDTPUB P16721 NVIC August 25, 2014

Licensing of Nuclear Installations

Health and Safety Policy and Procedures

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

PWROG Severe Accident Management Guidelines Development and Status

BHG Operational Awareness Program May 8, 1998 Surveillance Guide CMS 3.4 Revision 0 Temporary Changes Page 1 of 9 TEMPORARY CHANGES

University of Liverpool Radiation Risk Assessment. For Laboratories Using X-Ray Generators (Form RP-RA03).

805C-LF Check the Cashing of Domestic Postal Money Orders Status: Approved

DECONTAMINATION, AND REGISTRATION

Demobilization Plan Exercise 8 Overview Unit 8

Nurse Aide Training Program Policies

CHEMICAL HYGIENE PLAN

805C-LF Prepare Daily Money Order Business Report Status: Approved

Examination Centre Handbook 2014/2015

CNSC Type I Inspections of Activities and Devices for Nuclear Substances and Radiation Device Licensees Group 2.2 Licensees

Radiation Control Chapter Use of Radionuclides in the Healing Arts

AUSTIN/MOWER COUNTY-WIDE

Control Number: Item Number: 209. Addendum StartPage: 0

University of North Dakota Facilities Department Respiratory Protection Program. Table of Contents. 1.0 Introduction Purpose...

Commack School District District-Wide. Emergency Response Plan

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Health and Safety Code of Practice Code of Practice Safe Lone Working

October 23, Attention: Mr. Amory Quinn, President Cotter Corporation 7800 East Dorado Place, Suite 210 Englewood, CO 80111

U.S. Nuclear Regulatory Commission

University of Sussex. Radiation (Ionising) Safety Policy

UV21096 Health and safety in catering and hospitality

Safety Best Practices Manual

Decommissioning Licensing Process of Nuclear Installations in Spain Cristina CORREA SÁINZ.

EMERGENCY ARRANGEMENTS OF A NUCLEAR POWER PLANT

Agency for Health Care Administration

NUREG-0800 U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN ADMINISTRATIVE PROCEDURES - GENERAL REVIEW RESPONSIBILITIES

An Internal Audit of Lottery Drawings June 2016 Report #16-004

Smart Energy New Homes Program

Aseptic Processing Assessments

WC-OSH 109 Tagging and Isolation

RADIOLOGICAL MONITORING AND SURVEYS

SECURITY OFFICER, 3181 SENIOR SECURITY OFFICER, 3184 PRINCIPAL SECURITY OFFICER, 3200 CHIEF SECURITY OFFICER, 3187

C: Safety. Alberta Licensed Practical Nurses Competency Profile 23

Transcription:

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Cooper Nuclear Station Week of Examination: 12/4/00 Examination Level: RO Administrative Topic/Subject Description Describe method of evaluation: 1. ONE Administrative JPM, OR 2. TWO Administrative Questions Operating Test Number: A.1 Conduct of Operations Regular Reactor Plant Review Plant Parameter Verification JPM: Generate and review the Official Case following a power increase to 100%. (Will be used in system JPM B1-d (APRM gain adjustment). JPM: Perform Jet Pump and Recirc Pump Flow Check A.2 Equipment Control Tagging and Clearances JPM: Review the tagout for the Sparger Pump 1D K/A: 294001K102 IMPORTANCE: 3.9/4.5 A.3 Radiation Control A.4 Emergency Plan Knowledge of Significant Radiation Hazards Question: Concerning the rad levels in containment while performing In- Plant JPM B2-c (Venting Scram air header) Question: Concerning the emergency exposure and controls Question: Concerning general knowledge of the flowcharts K/A: 2.4.14 IMPORTANCE: 3.0 Accountability during Emergencies; Where to Report (RO) K/A: G2.4.29 IMPORTANCE: 2.6 Examiner: Chief Examiner:

SKL034-20-04 Administrative JPM P8200408.J Page 1 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: **Performed NOT Faulted** 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee Level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 18 minutes 5. Importance Rating: 3.25 6. NRC K/A 202001 K1.06 3.6/3.6 Directions to Examiner: 1. This JPM evaluates the trainee's ability to perform the daily Jet Pump and Recirc Pump Flow Check of the Daily Tech Specs Surveillance Log. 2. If this JPM is performed on the Simulator, only cues preceded by "#" should be given. 3. Observe the trainee during performance of the JPM for proper use of self-checking methods. 4. All blanks must be filled out with either initials or an NP for not performed ; an explanation may also be written in the space if desired by the examiner. 5. Brief the trainee, place the simulator in run, and tell the trainee to begin. ============================================================================== General Conditions: 1. The plant is operating at rated power with DEH in Mode 4. 2. Both Reactor Recirculation pumps are operating in individual manual control with pump flows balanced. General References: 1. Procedure 6.LOG.601 General Tools and Equipment: 1. Calculator. 2. Jet pump operability curves.

SKL034-20-04 Administrative JPM P8200408.J Page 2 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK Special Conditions, References, Tools, Equipment: 1. Simulator Setup: See Attachment 1. 2. Critical checks denoted by "*". 3. Simulator cues denoted by "#". Task Standards: 1. Accurately locate, identify, operate and/or manipulate all component controls required to be utilized to perform the daily Jet Pump and Recirc Pump Flow Check. 2. Accurately locate and identify all instrumentation required to be monitored to perform the daily Jet Pump and Recirc Pump Flow Check. 3. Correctly interpret instrument and system responses and their interrelationships when performing the daily Jet Pump and Recirc Pump Flow Check. Initiating Cue(s): The Control Room Supervisor directs you to perform the daily Jet Pump and Recirc Pump Flow Check as part of the routine shift activities. Notify the CRS when the task is complete. NOTE: Place the Simulator in RUN and tell the trainee to begin..

SKL034-20-04 Administrative JPM P8200408.J Page 3 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK Performance Checklist Standards Initials 1. Record indicated core flow Record Core flow from Recorder NBI-DPR/FR-95. CUE: Core Flow = 71.5. * 2. Record RR pump flow Record RR pump flow from RR-FR-163 for Pumps A & B. CUE: Pump A = 46.5; Pump B =46. * 3. Record RRMG Set speed Record RRMG Set speed from the following: a. RRFC-SIC-16A for RRMG A b. RRFC-SIC-16B for RRMG B CUE: RRMG A = 98; RRMG B = 97. * 4. Record Jet Pump Flow Record Jet Pump Flow from the following: a. NBI-FI-92A for LOOP A b. NBI-FI-92B for LOOP B CUE: LOOP A = 36; LOOP B = 35 * 5. Record Jet Pump Differential Pressure Record differential pressures from individual jet pump instruments NBI-FI-78A through NBI-FI-78Z on Panel 9-38 in control room. CUE: 1 = 44 8 = 43 15 = 49 2 = 44 9 = 44 16 = 48 3 = 43 10 = 46 17 = 42 4 = 41 11 = 43 18 = 43 5 = 48 12 = 44 19 = 45 6 = 47 13 = 42 20 = 44 7 = 43 14 = 43 * 6. Record B and A Average Add JP #1 through 10 and divide by 10 for LOOP B, then add JP #11 through 20 and divide by 10 for LOOP A. CUE: Average 44.3 for LOOP B and 44.3 for LOOP A. * Note: Curves are contained in the binder labeled Cooper Nuclear Station Jet Pump Operability Graphs and Instability Noise Level Data in the Control Room.

SKL034-20-04 Administrative JPM P8200408.J Page 4 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK Performance Checklist Standards Initials 7. Verify RR pump flow and RRMG set speed within limits. 8. Verify JP flow and RRMG set speed within limits. 9. Jet Pump ªp differs by #20% from established patterns. 10. Verify check 1 and 2 SAT or check 3 SAT. Determine that the values recorded in Items B and C are within the limits of the curve for Check 1. Determine that the values recorded in Items C and D are within the limits of the curve for Check 2. Determine that Jet Pump Îp differs by #20% from established patterns. (Check 3). Verify check 1 and 2 SAT or check 3 SAT. * * * * 11. Inform the CRS that the task is complete. Inform Control Room Supervisor that the daily Jet Pump and Recirc Pump Flow Check is Complete. #CUE: The CRS Acknowledges the report. This JPM is complete.

SKL034-20-04 Administrative JPM P8200408.J Page 5 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK ATTACHMENT 1 SIMULATOR SET-UP A. Materials Required B. Initialize the Simulator in IC-18. Batch File Name - none. C. Change the simulator conditions as follows: 1. Triggers 2. Malfunctions 3. Remotes 4. Overrides ZAONBIF192B to 31 5. Panel Setup D. Place the Simulator in RUN to allow conditions to stabilize. Note: If this JPM is to be performed more than once, snap the simulator into IC-0 after the panel setup is complete.

SKL034-20-04 Administrative JPM P8200408.J Page 6 of 7 RO-Admin-A1-2 Revision 08 ADMINISTRATIVE JPM FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK ATTACHMENT 2 Directions to Candidate: When I tell you to begin, you are to perform the daily Jet Pump and Recirc Pump Flow Check. Before you start, I will state the general plant conditions, the initiating cues and answer any questions you may have. When simulating, physically point to any meters, gauges, recorders and controls you would be using. State the position of controls as you would have manipulated them to perform the daily Jet Pump and Recirc Pump Flow Check. During performance, state the actions you are taking, e.g.: repositioning controls and observing instrumentation. General Conditions: 1. The plant is operating at rated power with DEH in Mode 4. 2. Both Reactor Recirculation pumps are operating in individual manual control with pump flows balanced. Initiating Cues: The Control Room Supervisor directs you to perform the daily Jet Pump and Recirc Pump Flow Check as part of the routine shift activities. Notify the CRS when the task is complete.

SKL034-20-04 Job Performance Measure P8200408.J Page 7 of 7 RO-Admin-A1-2 Revision 08 JOB PERFORMANCE MEASURE FOR OPERATIONS PERFORM JET PUMP OPERABILITY CHECK ATTACHMENT 3 Directions to Candidate: This Page May Be Given To The Candidate When I tell you to begin, you are to perform the daily Jet Pump and Recirc Pump Flow Check. Before you start, I will state the general plant conditions, the initiating cues and answer any questions you may have. When simulating, physically point to any meters, gauges, recorders and controls you would be using. State the position of controls as you would have manipulated them to perform the daily Jet Pump and Recirc Pump Flow Check. During performance, state the actions you are taking, e.g.: repositioning controls and observing instrumentation. General Conditions: 1. The plant is operating at rated power with DEH in Mode 4. 2. Both Reactor Recirculation pumps are operating in individual manual control with pump flows balanced. Initiating Cues: The Control Room Supervisor directs you to perform the daily Jet Pump and Recirc Pump Flow Check as part of the routine shift activities. Notify the CRS when the task is complete.

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: **Ensure that two of the three AGAFs are out of Spec. (APRM B, and APRM F)** 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 15 minutes 5. Importance Rating: 6. NRC K/A: Directions to Examiner: 1. This JPM evaluates the trainee's ability to generate and review an Official Case (AGAF) 2. If this JPM is performed on the Simulator, only the cues preceded by "#" should be given. 3. Observe the trainee during performance of the JPM for proper use of self-checking methods. 4. All blanks must be filled out with either initials or an NP for not performed ; an explanation may also be written in the space if desired by the examiner. 5. Brief the trainee, place the simulator in run, and tell the trainee to begin. ============================================================================== General Conditions: 1. Reactor power just increased from 90% to 100%. General References: General Tools and Equipment: 1. Special Conditions, References, Tools, Equipment: 1. Simulator Setup: See Attachment 1. 2. Critical checks denoted by "*". 3. Simulator cues denoted by "#". Task Standards: 1. Accurately locate, identify, operate and/or manipulate all component controls required to be utilized to generate and review an Official Case. 2. Accurately locate and identify all instrumentation required to be monitored to generate and review an Official Case.

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE 3. Correctly interpret instrument and system responses and their interrelationships when generating and reviewing an Official Case. Initiating Cue(s): The Control Room Supervisor has directed you to generate an Official Case (OD-3) following a 10% power increase to the new reactor power of 100%. Report on any discrepancies.

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE Performance Checklist Standards Initials 1. Locate CR Computer and Generate the Offical Case 2. Review the Offical Case Comments: Locate an appropriate control room computer and Generate Official Case by pressing the F3 button Review the Official Case and determine that two of the three AGAFs are not within + 2% of the reactor power of 100% * *

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE ATTACHMENT 1 SIMULATOR SET-UP A. Materials Required B. Initialize the Simulator in IC Ensure that two of the three AGAFs are out of Spec. (APRM B, and APRM F) C. Change the simulator conditions as follows: 1. Triggers 2. Malfunctions 3. Remotes 4. Overrides 5. Panel Setup Note: If this JPM is to be performed more than once, snap the simulator into IC-0 after the panel setup is complete.

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE ATTACHMENT 2 Directions to Candidate: When I tell you to begin, you are to generate and review an Official Case. Before you start, I will state the general plant conditions, the Initiating Cues and answer any questions you may have. When simulating, physically point to any meters, gauges, recorders and controls you would be using. State the position of controls as you would have manipulated them to generate and review an Official Case.. During performance, state the actions you are taking, e.g.: repositioning controls and observing instrumentation. General Conditions: 1. Reactor power just increased from 90% to 100%. Initiating Cues: The Control Room Supervisor has directed you to generate an Official Case (OD-3) following a 10% power increase to the new reactor power of 100%. Report on any discrepancies.

Page 1 of 6 Administrative JPM RO-Admin-A1-1 ADMINISTRATIVE JPM FOR OPERATIONS GENERATE AND REVIEW THE OFFICIAL CASE FOLLOWING POWER INCREASE ATTACHMENT 3 Directions to Candidate: This Page May Be Given To The Candidate When I tell you to begin, you are to generate and review an Official Case. Before you start, I will state the general plant conditions, the Initiating Cues and answer any questions you may have. When simulating, physically point to any meters, gauges, recorders and controls you would be using. State the position of controls as you would have manipulated them to generate and review an Official Case. During performance, state the actions you are taking, e.g.: repositioning controls and observing instrumentation. General Conditions: 1. Reactor power just increased from 90% to 100%. Initiating Cues: The Control Room Supervisor has directed you to generate an Official Case (OD-3) following a 10% power increase to the new reactor power of 100%. Report on any discrepancies.

Page 1 of 6 Administrative JPM RO-Admin-A2 ADMINISTRATIVE JPM FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee Level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 20 minutes 5. Importance Rating: 6. NRC K/A: Directions to Examiner: 1. This JPM evaluates the trainee's ability to review tagout of sparger pump 1D. 2. If this JPM is performed on the Simulator, only cues preceded by "#" should be given. 3. Observe the trainee during performance of the JPM for proper use of self-checking methods. 4. All blanks must be filled out with either initials or an NP for not performed ; an explanation may also be written in the space if desired by the examiner. 5. Brief the trainee, place the simulator in run, and tell the trainee to begin. ============================================================================== General Conditions: 1. The plant is operating at100% power General References: 1. Administrative Procedure 0.9 Tagout General Tools and Equipment: 1. Facility Drawings Special Conditions, References, Tools, Equipment: 1. Simulator Setup: See Attachment 1. 2. Critical checks denoted by "*". 3. Simulator cues denoted by "#". Task Standards:

Page 2 of 6 Administrative JPM RO-Admin-A2 ADMINISTRATIVE JPM FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D 1. Accurately locate, identify, and interpret facility drawings in order to properly review the tagout of the sparger pump 1D. 2. Demonstrate the ability to review and interpret information located on the system tagout for the sparger pump 1D. Initiating Cue(s): The Control Room Supervisor directs you to be the verifier for the tagout of the Sparger Pump 1D as per admin procedure 0.9 Tagout. Notify the CRS when the task is complete.

Page 3 of 6 Administrative JPM RO-Admin-A2 ADMINISTRATIVE JPM FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D Performance Checklist Standards Initials 1. Obtain Correct Drawings 2. Locate Discrepancy Obtain the correct facility drawings for the Sparger Pump 1D Discover that Screen Wash for pump D Outboard Seal Shutoff is improperly labeled as CW-V-738. Should be labeled as CW-V-756. * * 3. Notify CRS Notify CRS of the discrepancy and comment as to the correct valve. * Comments:

Page 4 of 6 Administrative JPM RO-Admin-A2 ADMINISTRATIVE JPM FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D ATTACHMENT 1 SIMULATOR SET-UP A. Materials Required B. Initialize the Simulator. Batch File Name - none. C. Change the simulator conditions as follows: 1. Triggers 2. Malfunctions 3. Remotes 4. Overrides 5. Panel Setup D. Place the Simulator in RUN to allow conditions to stabilize. Note: If this JPM is to be performed more than once, snap the simulator into IC-0 after the panel setup is complete.

Page 5 of 6 Administrative JPM RO-Admin-A2 ADMINISTRATIVE JPM FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D ATTACHMENT 2 Directions to Candidate: When I tell you to begin, you are to review the tagout for the Sparger Pump 1D. Before you start, I will state the general plant conditions, the initiating cues and answer any questions you may have. General Conditions: 1. The plant is operating at100% power Initiating Cues: The Control Room Supervisor directs you to be the verifier for the tagout of the Sparger Pump 1D as per admin procedure 0.9 Tagout (See Attachment #4). Notify the CRS when the task is complete.

Page 6 of 6 Job Performance Measure RO-Admin-A1-2 JOB PERFORMANCE MEASURE FOR OPERATIONS REVIEW TAGOUT OF SPARGER PUMP 1D ATTACHMENT 3 Directions to Candidate: This Page May Be Given To The Candidate When I tell you to begin, you are to review the tagout of the Sparger Pump 1D. Before you start, I will state the general plant conditions, the initiating cues and answer any questions you may have. General Conditions: 1. The plant is operating at100% power Initiating Cues: The Control Room Supervisor directs you to be the verifier for the tagout of the Sparger Pump 1D as per admin procedure 0.9 Tagout (See Attachment #4). Notify the CRS when the task is complete.

ATTACHMENT 4 CLEARANCE ORDER FORMS AND WORKSHEETS SECTION 1 - CLEARANCE ORDER SECTION STATION: Cooper EQUIPMENT: CW-P-SCWP 1D (Sparger Pump 1D) PURPOSE: Isolate and Drain pump due to a gross packing leak REQUESTED BY: Shift Supervisor REFERENCES: REMARKS: PREPARED BY: Extra Licensed Operator VERIFIED BY: CLEARANCE GRANTED BY: DATE: TIME: SECTION HOLDER: DATE: TIME: COMPONENT ID DESCRIPTION TAG POS LOCATION TYPE CW-SW-SCWP1D (SC) CW-SW-SCWP1D (SS) EE-CB-4160 (SCWP1D) Screen Wash Pump 1D Control Switch (Start-Stop) Screen Wash Pump 1D Select Switch (Standby-Manual) Sparger Pump D Pull-To- Lock Manual Racked- Out C&D Screen Wash Pump Area C&D Screen Wash Pump Area Non-Critical Switch Danger Danger Danger PLACED BY VERIFIED BY

ATTACHMENT 4 CLEARANCE ORDER FORMS AND WORKSHEETS COMPONENT ID DESCRIPTION TAG POS LOCATION TYPE CW-V-237 CW-V-753 CW-V-738 CW-V-236 CW-V-750 CW-V-242 CW-V-754 CW-V-757 Screen Wash Pump D Discharge Screen Wash Pump D Inboard Seal Shutoff Screen Wash Pump D Outboard Seal Shutoff Screen Wash Pump D Suction Screen Wash Pump D Drain Screen Wash Pump D Vent Screen Wash Pump D Inboard Seal Strainer Drain Screen Wash Pump D Outboard Seal Strainer Drain Closed Closed Closed Closed Open Open Open Open C&D Screen Wash Pump Area Above D Sparger Pump Above D Sparger Pump C&D Screen Wash Pump Area C&D Screen Wash Pump Area C&D Screen Wash Pump Area Above D Sparger Pump Above D Sparger Pump Danger Danger Danger Danger Danger Danger Danger Danger PLACED BY VERIFIED BY

Administrative Question RO-Admin-A3-a Page 1 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 15 minutes 5. Importance Rating: 6. NRC K/A: Directions to Examiner: 1. This JPM evaluates the trainee's ability to perform 2. The examiner is to obtain the JPM Comment Form (Attachment C of ODG 206) prior to administering the JPM. 3. If this JPM is performed on the Simulator, only the cues preceded by "#" should be given. 4. Observe the trainee during performance of the JPM for proper use of self-checking methods. 5. All blanks must be filled out with either initials or an NP for not performed ; an explanation may also be written in the space if desired by the examiner. 6. Brief the trainee, place the simulator in run, and tell the trainee to begin. ============================================================================== General Conditions: 1. A failure of RPS and ARI to insert the control rods has occurred. 2. The Control Room operator has placed all keylock RPS test trip switches to TRIP. 3. All CRD HCU scram valves remain closed. 4. TSC is not yet operational. 5. No ARMs are alarming. 6. The In-Containment Rad Monitors are reading 100 REM/HR. General References: 1. Procedure 5.8.3 Alternate Rod Insertion Methods General Tools and Equipment: 1.

Administrative Question RO-Admin-A3-a Page 2 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION Special Conditions, References, Tools, Equipment: 1. Simulator Setup: See Attachment 1. 2. Critical checks denoted by "*". 3. Simulator cues denoted by "#". Task Standards: 1. Accurately locate, identify, the procedure and controls utilized during a dispatching personnel for EOP actions. Initiating Cue(s): Given the specific conditions stated above, and the CRS directs you to vent the Scram Air Header, what are the guidelines for dispatching personnel for EOP actions. Please write your response below.

Administrative Question RO-Admin-A3-a Page 3 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION Performance Checklist Standards Initials 1. If no Station Area Radiation Monitor (Panel 9-11) alarms exist, dispatched personnel should follow standard CNS Radiological Protection practices and procedures. 2. If Station Area Radiation Monitors in travel path and work location of dispatched personnel are alarming, but on-scale, dispatched personnel shall carry a survey instrument capable of monitoring radiation dose rates in travel path and work areas. Dispatched personnel accompanied by a Radiological Protection Technician or Chemistry/Radiological Protection On-Site Availability Technician also satisfies this criteria. 3. If dispatched personnel must travel through or work in vicinity of an off-scale Station Area Radiation Monitor, they shall be accompanied by a Radiological Protection Technician or Chemistry/Radiological Protection On-Site Availability Technician. 4. If DRYWELL RAD MONITOR RMA-RM-40A or DRYWELL RAD MONITOR RMA-RM-40B (PNL 9-02) is reading $ 10 4 rem/hour, entry into Secondary Containment is prohibited until TSC is operational and personnel can be dispatched per Procedure 5.7.15. * * * * Comments:

Administrative Question RO-Admin-A3-a Page 4 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION ATTACHMENT 1 SIMULATOR SET-UP A. Materials Required B. Initialize the Simulator in IC Batch File Name - none. C. Change the simulator conditions as follows: 1. Triggers 2. Malfunctions 3. Remotes 4. Overrides 5. Panel Setup Note: If this JPM is to be performed more than once, snap the simulator into IC-0 after the panel setup is complete.

Administrative Question RO-Admin-A3-a Page 5 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION ATTACHMENT 2 General Conditions: 1. A failure of RPS and ARI to insert the control rods has occurred. 2. The Control Room operator has placed all keylock RPS test trip switches to TRIP. 3. All CRD HCU scram valves remain closed. 4. TSC is not yet operational. 5. No ARMs are alarming. 6. The In-Containment Rad Monitors are reading 100 REM/HR. Initiating Cues: Given the specific conditions stated above, and the CRS directs you to vent the Scram Air Header, what are the guidelines for dispatching personnel for EOP actions. Please write your response below.

Administrative Question RO-Admin-A3-a Page 6 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS DISPATCHING PERSONNEL FOR EOP ACTION ATTACHMENT 3 This Page May Be Given To The Candidate OPEN REFERENCE OPEN REFERENCE OPEN REFERENCE OPEN REFERENCE General Conditions: 1. A failure of RPS and ARI to insert the control rods has occurred. 2. The Control Room operator has placed all keylock RPS test trip switches to TRIP. 3. All CRD HCU scram valves remain closed. 4. TSC is not yet operational. 5. No ARMs are alarming. 6. The In-Containment Rad Monitors are reading 100 REM/HR. Initiating Cues: Given the specific conditions stated above, and the CRS directs you to vent the Scram Air Header, what are the guidelines for dispatching personnel for EOP actions. Please write your response below.

Administrative Question RO-Admin-A3-b Page 1 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS RADIATION EXPOSURE AND CONTROLS Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 15 minutes 5. Importance Rating: 6. NRC K/A: Directions to Examiner: 1. This JPM evaluates the trainee's ability to perform 2. The examiner is to obtain the JPM Comment Form (Attachment C of ODG 206) prior to administering the JPM. 3. If this JPM is performed on the Simulator, only the cues preceded by "#" should be given. 4. Observe the trainee during performance of the JPM for proper use of self-checking methods. 5. All blanks must be filled out with either initials or an NP for not performed ; an explanation may also be written in the space if desired by the examiner. 6. Brief the trainee, place the simulator in run, and tell the trainee to begin. ============================================================================== General Conditions: The plant has just experienced a severe accident with an uncontrolled radiological release in progress. To mitigate this event and to terminate the radiological release an isolation valve located in the RCA in a very high radiation area needs to be manually secured. You are thirty years old, your current annual dose is 2 rem, and your accumulated life time exposure is 55 rem. General References: 1. Task Standards: 1. Accurately locate, identify, the procedure and controls utilized during a dispatching personnel for EOP actions. Initiating Cue(s): Given the specific conditions stated above, who can authorize you to receive an exposure in excess of the 10CFR20 exposure limits and what is the maximum emergency exposure limit allowed for preventing major damage to equipment and preventing release of radioactive materials? Please write your response below.

Administrative Question RO-Admin-A3-b Page 2 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS RADIATION EXPOSURE AND CONTROLS Performance Checklist Standards Initials 1. Emergency Director can give authorization of exposure in excess of 10CFR20 exposure limits 2. 25 rem Comments: Reference: Procedure 5.7.12 Emergency Exposure Limits

Administrative Question RO-Admin-A3-b Page 3 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS RADIATION EXPOSURE AND CONTROLS ATTACHMENT 1 CLOSED REFERENCE CLOSED REFERENCE CLOSED REFERENCE General Conditions: The plant has just experienced a severe accident with an uncontrolled radiological release to the environment is in progress. To mitigate this event and to terminate the radiological release an isolation valve located in the RCA in a very high radiation area needs to be manually secured. You are thirty years old, your current annual dose is 2 rem, and your accumulated life time exposure is 55 rem. Initiating Cues: Given the specific conditions stated above, who can authorize you to receive an exposure in excess of the 10CFR20 exposure limits and what is the maximum emergency exposure limit allowed for preventing major damage to equipment and preventing release of radioactive materials? Please write your response below.

Administrative Question RO-Admin-A3-b Page 4 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS RADIATION EXPOSURE AND CONTROLS ATTACHMENT 2 This Page May Be Given To The Candidate CLOSED REFERENCE CLOSED REFERENCE CLOSED REFERENCE General Conditions: The plant has just experienced a severe accident with an uncontrolled radiological release to the environment is in progress. To mitigate this event and to terminate the radiological release an isolation valve located in the RCA in a very high radiation area needs to be manually secured. You are thirty years old, your current annual dose is 2 rem, and your accumulated life time exposure is 55 rem. Initiating Cues: Given the specific conditions stated above, who can authorize you to receive an exposure in excess of the 10CFR20 exposure limits and what is the maximum emergency exposure limit allowed for preventing major damage to equipment and preventing release of radioactive materials? Please write your response below.

Administrative Question RO-Admin-A4-a Page 1 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS KNOWLEDGE OF GENERAL GUIDELINES FOR EOP FLOWCHART USAGE Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 15 minutes 5. Importance Rating: 6. NRC K/A: 2.4.14 3.0/3.9 ============================================================================== General Conditions: The plant is operating at 98% reactor power with several SRVs leaking. Average Torus Pool temperature increases to 95 EF and EOP-3A is entered. Initiating Cues: When is it permitted to exit the EOP flowcharts? General References: 1. EOP 5.8 Task Standards: 1. To demonstrate knowledge concerning the EOP flowcharts.

Administrative Question RO-Admin-A4-a Page 2 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS KNOWLEDGE OF GENERAL GUIDELINES FOR EOP FLOWCHART USAGE Performance Checklist Standards Initials 2. EOP flowcharts may be exited when it is determined that an emergency requiring guidance provided by EOP flowcharts no longer exists. Comments: Reference: EOP 5.8

Administrative Question RO-Admin-A4-a Page 3 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS KNOWLEDGE OF GENERAL GUIDELINES FOR EOP FLOWCHART USAGE ATTACHMENT 1 CLOSED REFERENCE CLOSED REFERENCE CLOSED REFERENCE General Conditions: The plant is operating at 98% reactor power with several SRVs leaking. Average Torus Pool temperature increases to 95 EF and EOP-3A is entered. Initiating Cues: When is it permitted to exit the EOP flowcharts?

Administrative Question RO-Admin-A4-a Page 4 of 4 ADMINISTRATIVE QUESTION FOR OPERATIONS KNOWLEDGE OF GENERAL GUIDELINES FOR EOP FLOWCHART USAGE ATTACHMENT 2 This Page May Be Given To The Candidate CLOSED REFERENCE CLOSED REFERENCE CLOSED REFERENCE General Conditions: The plant is operating at 98% reactor power with several SRVs leaking. Average Torus Pool temperature increases to 95 EF and EOP-3A is entered. Initiating Cues: When is it permitted to exit the EOP flowcharts?

Administrative Question RO-Admin-A.4-b Page 1 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY Candidate: Examiner: Pass: Fail: Examiner Signature: Date: Additional Program Information: **Closed Question ** 1. Appropriate Performance Locations: CR/SIM 2. Appropriate Trainee level: RO/SRO 3. Evaluation Method: Simulate Perform 4. Performance Time: 15 minutes 5. Importance Rating: 6. NRC K/A: Directions to Examiner: 1. This JPM evaluates the trainee's knowledge as to where to report during a notification of unusual event or greater. ============================================================================== General Conditions: 1. Notification of Unusual Events has been declared. The Emergency Director requires personnel assembly and accountability. General References: 1. Procedure 5.7.10 Personnel Assembly and Accountability (page 2) General Tools and Equipment: 1. Special Conditions, References, Tools, Equipment: 1. Simulator Setup: See Attachment 1. 2. Critical checks denoted by "*". 3. Simulator cues denoted by "#". Task Standards: 1. Accurately identify where visitors and on-duty personnel are to report during a Notification of Unusual Event when the Emergency Director directs personnel assembly and accountability..

Administrative Question RO-Admin-A.4-b Page 2 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY Initiating Cue(s): You are an on-duty reactor operator who has been tasked by the CRS to escort/tour a potential new contractor (classified as a visitor) through the plant. You both are outside of containment when you hear the Emergency Director declare a Notification of Unusual Event and request personnel assembly and accountability. Where do you and you visitor report in this event?

Administrative Question RO-Admin-A.4-b Page 3 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY Performance Checklist Standards Initials 1. Personnel escorting visitors or tours shall take them immediately to the exit turnstile and direct them to report to the Training Building Classrooms J, H, or I for assembly 2. Escort shall then report to the Control Room * * Comments:

Administrative Question RO-Admin-A.4-b Page 4 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY ATTACHMENT 1 SIMULATOR SET-UP A. Materials Required B. Initialize the Simulator in IC Batch File Name - none. C. Change the simulator conditions as follows: 1. Triggers 2. Malfunctions 3. Remotes 4. Overrides 5. Panel Setup Note: If this JPM is to be performed more than once, snap the simulator into IC-0 after the panel setup is complete.

Administrative Question RO-Admin-A.4-b Page 5 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY ATTACHMENT 2 General Conditions: 1. Notification of Unusual Events has been declared. The Emergency Director requires personnel assembly and accountability. Initiating Cue(s): You are an on-duty reactor operator who has been tasked by the CRS to escort/tour a potential new contractor (classified as a visitor) through the plant. You both are outside of containment when you hear the Emergency Director declare a Notification of Unusual Event and request personnel assembly and accountability. Where do you and you visitor report in this event? Please write your answer below

Administrative Question RO-Admin-A.4-b Page 6 of 6 ADMINISTRATIVE QUESTION FOR OPERATIONS PERSONNEL ASSEMBLY AND ACCOUNTABILITY ATTACHMENT 3 This Page May Be Given To The Candidate General Conditions: 1. Notification of Unusual Events has been declared. The Emergency Director requires personnel assembly and accountability. Initiating Cue(s): You are an on-duty reactor operator who has been tasked by the CRS to escort/tour a potential new contractor (classified as a visitor) through the plant. You both are outside of containment when you hear the Emergency Director declare a Notification of Unusual Event and request personnel assembly and accountability. Where do you and you visitor report in this event? Please write you answer below.