L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION

Size: px
Start display at page:

Download "L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION"

Transcription

1 Engineering Specification Signalling L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION Version: 1

2 ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 Approval Name Position Signature Document Endorser Louisa Waymouth Manager Standards Approving Manager Phil Ellingworth Chief Engineer Amendment Record Approval Date Version Description 20/06/ Rebadge VRIOGS Signal Identification and General Information. No change to the technical content. Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 2 of 133

3 ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 PREFACE This Specification replaces VRIOGS Signal Identification and General Information. The contents of this Specification were prepared by the Victorian Rail Industry Operators Group (VRIOG). This VRIOG Standard has been rebadged as an MTM document due to the retirement of VRIOG Standards as of 30 th June This Specification will be managed under the Engineering Standards Development Procedure (L1-CHE-PRO-032). As documents are uncontrolled once printed, it is imperative to check the currency of the Document on The Depot or the MTM s Document Portal which is available externally at All MTM Standards and Specifications are periodically reviewed, and new editions are published which incorporate learnings and Technical Notes (formerly known as Design Practice Notes). Technical Notes are issued between editions which correct any errors or ambiguities contained in an MTM Standard/Specifications. Standards and Specifications may also be withdrawn and/ or replaced. In the event of conflicts or discrepancies between different types of technical documents, refer to the order of precedence as defined in Chief Engineer s Guideline Engineering Standards Listing (L1-CHE-GDL-005). Note: Any clarification described in a Technical Note or Design Practice Note shall take precedence over the impacted clause or clauses in the associated MTM Standard/Specification. In the event a clause within a Standard/Specification is not achievable a waiver will need to be raised, please refer to the Engineering Waiver Procedure - L1-CHE-PRO-001. Note: MTM does not have the authority to grant waivers on any Standards/Specifications or clauses within a Standard/Specification which relate to Government Regulations or Legislation, e.g. Disability Discrimination Act. Referencing this document Clauses and subclauses of this document should be referenced using the following format style L1-CHE-XXX-YYY Clause Z.Z.Z. Referencing the VRIOGS document number is not required. Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 3 of 133

4 ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 THIS PAGE IS INTENDED TO BE BLANK Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 4 of 133

5 Victorian Rail Industry Operators Group Standards VRIOGS Signal Equipment Identification and General Information Revision: Revision A Issue Date: 12/10/2009

6 ii VRIOGS Revision A VRIOGS Signal Equipment Identification and General Information Revision A Issue Date: 12/10/2009 APPROVAL STATUS APPROVER STATUS DATE QUALIFICATIONS Document Developer VRIOG Steering Committee Approved All Sections Accredited Rail Operator Metropolitan Train (Metro Trains Melbourne) Intrastate Train (V/Line) Interstate Train (ARTC) Tram (Yarra Trams) For any queries please contact vriogs@transport.vic.gov.au.

7 VRIOGS Revision A iii PURPOSE OF THE STANDARD The Standard has been created through the collaboration of members of the Victorian Rail Industry Operators Group (VRIOG) for the purpose of establishing standards which, if implemented throughout the Victorian Rail Network, will facilitate the interoperability of infrastructure. The use of the Standard is not prescribed by law but, if adopted, conformity with the provisions of the Standard is mandatory in order that the purpose of the Standard be achieved. DISCLAIMER The Standard is published by the Director of Public Transport for information purposes only and does not amount to any kind of advice. Each person is responsible for making his or her own assessment of all such information and for verifying such information. The content of this publication is not a substitute for professional advice. The Director of Public Transport and VRIOG accept no liability for any loss or damage to any person, howsoever caused, for information contained in this publication, or any purported reliance thereon. COPYRIGHT STATEMENT Director of Public Transport This publication is copyright. No part may be reproduced by any process except in accordance with the provisions of the Copyright Act. Where information or material is so used, it should be used accurately and the Standard should be acknowledged as the source of the information.

8 iv VRIOGS Revision A TABLE OF CONTENTS SECTION 1.0 CONVENTIONS... 1 SECTION 2.0 DEFINITIONS... 2 SECTION 3.0 SCOPE AND GENERAL Scope Background... 3 SECTION 4.0 GENERAL... 4 SECTION 5.0 TRANSFORMERS... 5 SECTION 6.0 REFERENCE LIST VRI TO IRONCORE... 6 SECTION 7.0 REFERENCE LIST IRONCORE TO VRI... 9 SECTION 8.0 REFERENCE LIST SECONDARY VOLTAGE TO VRI SECTION 9.0 COMPONENT CIRCUITS AND PHOTOS SECTION 10.0 REFERENCES

9 VRIOGS Revision A 1 SECTION 1.0 CONVENTIONS 1) Words or phrases that appear capitalised out of context are defined within the Definitions section of this VRIOG Standard. 2) The word Shall is to be understood as mandatory. 3) The word Should is to be understood as non-mandatory i.e. advisory or recommended. 4) Uncontrolled Standards may not be referenced within the VRIOG Standards. These include former PTC Standards, Franchisee Standards, Franchisee Subcontractor Standards and Infrastructure Lessee Standards. 5) Controlled Standards, including Australian Standards and other VRIOG Standards, may be referenced but only if: The referenced item can not be adequately explained with an amount of text that could not reasonably be inserted into the body of the Standard. The reader is not referenced to another Controlled Standard necessary for the item to be adequately explained i.e. one document link only. The referenced document is a Figure or table and could not reasonably be included in the appendices of the Standard. 6) The format employed in the VRIOG Standards is compatible with Australian Standards, and will be used from this point on. 7) The numbering system for the VRIOG Standards is chronologically sequential from the point of introduction, and is not based on any form of interpretive system. 8) The VRIOG Standards contain engineering information necessary to operate a safe Railway. VRIOG Standards will not contain any information that can be construed as a work instruction, procedure, process or protocol. This information forms the basis of each individual entity s Safety Accreditation Certification, and, as such, is outside the scope of VRIOG Standards.

10 2 VRIOGS Revision A SECTION 2.0 DEFINITIONS Terminology used and/or applied in this Standard is defined as follows:- ARTC Terminology Accredited Rail Operator (ARO) DMS DOT Infrastructure Manager Ironcore PTC PTD VR Definition Australian Rail Track Corporation A Rail Infrastructure Manager or Rolling Stock Operator who is accredited under Part 5 of the Rail Safety Act VicTrack Drawing Management System Department of Transport The Manager of the rail infrastructure system and owner of the associated rail safety management systems A Manufacturer of power supplies and battery chargers, etc Public Transport Corporation The Public Transport Division of the Department of Transport Victorian Railways VRI Victorian Railways Industry VRIOGS The Victorian Rail Industry Operators Group comprising the following members: VicTrack V/Line Passenger Metro Trains Melbourne Yarra Trams Australian Rail Track Corporation (ARTC) Public Transport Division (PTD) of the Department of Transport (DOT) Table 1 - Terminology

11 VRIOGS Revision A 3 SECTION 3.0 SCOPE AND GENERAL 3.1 Scope This Standard captures the general specifications and identifying photos of various signalling equipment items; such as power supplies, transformers, battery chargers, rectifiers, etc for use within the Victorian Railway Network. It also contains a number of conversion charts between part numbers for Iron Core type signalling power supplies, battery chargers, etc to that of the Victorian Rail Industry part numbers. This Standard is intended to be dynamic, in that it will continually be updated to capture signalling equipment, by those within the Industry. 3.2 This is the Standard that is used as within the Victorian Railway Network to capture signal equipment such as transformers, power supplies, battery chargers, etc. This Standard should be read in conjunction with all other VRIOGS signal equipment technical specifications, and reference also made to the ARO s type approved signal equipment list. 3.3 Background This Standard replaces all previous versions of Railway Signal Equipment Technical General Specifications, such as and not limited to; Victorian Railways Signal Equipment Technical General Specifications Public Transport Corporation (PTC) Signal Equipment Technical General Specifications Thiess Infraco Signal Equipment Technical General Specifications

12 4 VRIOGS Revision A SECTION 4.0 GENERAL Please note that the following drawings have been created by the author for inclusion within this document. They were not part of the original A2 size B drawings of the Victorian Railways 7B1521 to 12B1521 1B1995 to 6B1995 9B1995, all B1996 9B1997 to 12B1997 It should be noted that within the specification there are a number of items which are OBSOLETE and as such have been replaced by other listed items, from within this specification, and are captured within this specification purely for maintenance functions to identify the equipment and its purpose. There are also items that have been SUPERSEDED by other items, and these are also listed, as also their replacements This specification should be read in conjunction with all other VRIOGS signal equipment technical specifications, and reference also made to the ARO s type approved signal equipment list. While every endeavour has been made to ensure the information contained within this document is accurate and up to date errors may have occurred. Please provide any corrections, additional photos or comments to the DOT Manager of Standards.

13 VRIOGS Revision A 5 SECTION 5.0 TRANSFORMERS 1. In general all transformers shall be of single phase, double wound; metal clad, natural air cooling type, with rated output specified, to operate from single phase 25 or 50 hertz supply voltage with a temperature rise not exceeding 55 C. 2. Transformers shall be designed for indoor use and wall mounting. 3. The exterior of transformers for use on 50-hertz supply shall be coloured yellow. 4. All winding ends and tapings shall be brought to easily accessible terminals. 5. The positive terminals of the same instantaneous polarity shall be marked by red disc. 6. A label giving Manufacture s name and serial number of transformer and rating plate shall be securely fitted to the front (preferably) of each transformer.

14 6 VRIOGS Revision A SECTION 6.0 REFERENCE LIST VRI TO IRONCORE VRI No. Ironcore Voltage Rating Freq 1B 954 T1 / / V 16VA 25Hz 2B 954 T6 / / V 25VA 25Hz 3B 954 T6 / / V 75VA 25Hz 4B / 3-18V 25VA 50Hz 5B 954 T1 / / 3-18V 25VA 25Hz 6B 954 Obsolete see 7B954 7B 954 T6 / / 6-6V 75VA 25Hz 8B 954 T1 / / V 30VA 25Hz 9B 954 T6 / / V 150VA 25Hz 10B 954 Obsolete see 7B B 954 T6 / / V 25VA 25Hz 12B 954 T6 / / 230V 150VA 50Hz 1B 1126 T5 / / 6-6V 5VA 25Hz 2B 1126 T6 / / 21-36V 50VA 25Hz 3B 1126 T6 / / 6-6V 100VA 50Hz 4B 1126 T5 / / 1-6V 1VA 25Hz 5B 1126 Obsolete see 7B1390 6B 1126 T5 / / V 20VA 50Hz 7B 1126 T3 / / 3-18V 25VA 50Hz 8B 1126 T1 / / 7-8.5V 85VA 50Hz 9B 1126 T9 / / V 500VA 50Hz 10B 1126 T3 / / 110V 25VA 50Hz 11B / V 37VA 50Hz 12B 1126 T5 / 199 Obsolete see 1B1126 1B 1390 T6 / / 3-18V 90VA 50Hz 2B 1390 T6 / / V 125VA 50Hz 3B / 3-1 8V 90VA 25Hz 4B / V 25VA 25Hz 5B / 30-34V 85VA 25Hz 6B 1390 T1 / / 11-12V 25VA 50Hz 7B 1390 T3 / / 110V 5VA 25Hz 8B 1390 ST / 110V 1.5kVA 50Hz 9B 1390 ST / 110V 3kVA 50Hz 10B 1390 T1 / / 9-12V 30VA 25Hz 11B 1390 T1 / 1354 Superseded by 10B B 1390 T1 / / 3-18V 40VA 50Hz 1B 1521 T10 / / 110V 750VA 50Hz 2B / 110V 2kVA 50Hz 3B 1521 T1 / / 3-18V 40VA 50Hz 4B 1521 T10 / / 110V 1kVA 50Hz 5B / 110V 4kVA 50Hz 6B 1521 T3 / / 120V 30VA 50Hz 7B 1521 T14 / / 125V 2kVA 50Hz 8B 1521 T14 / / 125V 2kVA 50Hz 9B 1521 T14 / / 125V 3kVA 50Hz

15 VRIOGS Revision A 7 VRI No. Ironcore Voltage Rating Freq 10B 1521 T14 / / 230V 3kVA 50Hz 11B 1521 T14 / / 440V 4kVA 50Hz 12B 1521 T14 / / 440V 5kVA 50Hz 1B 1995 T9 / 1648M 110 / 12Vdc 8A 50Hz 2B 1995 T9 / 1649M 110 / 24Vdc 8A 50Hz 3B 1995 HS1 12Vdc 4B 1995 Voltage Sensing Relay 5B 1995 T3 / / 2Vdc 3A 5B 1995 T9 / / 50Vdc 500VA 50Hz 6B 1995 ST / 24Vdc 10A 50Hz 7B 1995 T14 / / 110V 3kVA 50Hz 8B / 460V 3kVA 25Hz 9B 1995 T5 / / 50Vdc 500VA 25Hz 10B 1995 T14 / / 110V 5kVA 11B 1995 ST / 110V 6kVA 12B 1995 na 1B 1996 Current Sensor 30mA 2B 1996 Track Rectifier NT Type 3B 1996 Track rectifier BT Type 4B 1996 na 5B 1996 T9 / 1440M 110 / 15Vdc 25A 6B / 15.7Vdc 7.5A 50Hz 7B 1996 na 8B 1996 Current Sensor 30mA 9B Vdc 6A 10B 1996 T5 / Vac 200mA 11B / 24Vdc 20A 12B Vdc 6A 1B 1997 Contact Protection Unit 3A 2B 1997 Slow Release Unit 3B 1997 T6 / / 3-18Vdc 5A 90VA 4B 1997 Obsolete see 4B1995 5B 1997 T3 / Vdc 1.5A 6B 1997 T3 / Vdc 0.2A 7B 1997 T1 / / 4.2Vdc 50VA 25Hz 8B 1997 T1 / / 12Vdc 50VA 50Hz 9B 1997 T9 / / 50Vdc 250VA 25Hz 10B 1997 Negative Regulator 0.5A 11B 1997 Approach Indicator 12B / 24Vdc 3A 25Hz 1B 1998 T1 / / 18Vdc 2A 25VA 50Hz 2B , 4, 6, 10, 12V L.E.D Unit 3B , 4, 6, 10, 12V L.E.D Unit 4B 1998 T5 / / 50Vdc 10VA 25Hz 5B 1998 Obsolete see 9B1998 2A 6B 1998 T1 / / 6Vdc 45VA 25Hz 7B 1998 T9 / / 24Vdc 10A 260VA 8B , 4, 6, 10, 12V L.E.D Unit 9B Vdc Flasher Card 2A

16 8 VRIOGS Revision A VRI No. Ironcore Voltage Rating Freq 10B / 24Vdc 11B , 4, 6, 10, 12V L.E.D Unit 12B 1998 ST / 50Vdc 1kVA 25Hz 1B 1999 T9 / / 12Vdc 250VA 25Hz 2B 1999 DD07 12Vdc / 50Vdc 50VA 3B 1999 T0 / 34 10Vdc / 50Vdc 4B 1999 T5 / / 6Vdc 5VA 25Hz 5B 1999 Slow Release Unit 1A 6B 1999 SF1 12Vdc 16A 7B 1999 na 8B 1999 T1 / / 50Vdc 9B 1999 T6 / / 50Vdc 50VA 25Hz 10B 1999 Obsolete see 12B1997 3A 11B 1999 Slow Release Unit 12B 1999 Bridge Rectifier 4A 1B 2000 T5 / / 50Vdc 10VA 25Hz 2B / 12-24Vdc 10VA 50Hz 3B 2000 T5 / / 12Vdc 6VA 25Hz 4B 2000 T3 / 59A 12Vdc / Vac 1.5A 27VA 5B 2000 T6 / Vdc / Vac 1.5A 6B 2000 T9 / / 12Vdc 20A 400VA 25Hz 7B Vdc TDU 8B Vdc TDU 9B Vdc 2TDU 3VA 10B 2000 Obsolete see 6B A 11B 2000 T10 / / 21Vdc 17A 400VA 25Hz 11B 2000M T10 / / 21Vdc (16Vdc) 25A 50Hz 12B 2000 T9 / / 50Vdc 5A Table 2 - Cross reference list -VRI to Ironcore

17 VRIOGS Revision A 9 SECTION 7.0 REFERENCE LIST IRONCORE TO VRI Ironcore VRI No. Ironcore VRI No. Ironcore VRI No. DD O7 2B 1999 T B 1998 T B 1521 T5 594 T B 2000 HS 1 3B 1995 T5 38 9B 1995 T B 2000 T5 38 1B 2000 T B 1521 SF 1 6B 1999 T5 73 3B 2000 T B 1126 T B 1126 T B 2000M ST 251 T B 1126 ST B 1995 T B 1999 T B 1390 ST 1114 T B 1126 T13 38 ST 1115 T B 1126 ST B 1998 T B 1996 T B 1995 ST B 1390 T B 1521 ST B 1998 T B 954 T B 1521 ST B 1390 T B 1999 T B 1521 ST B 1995 T B 1126 T B 1521 T B 954 T B 1521 T0 34 3B 1999 T B 954 T B 1521 T B 1390 T B 1995 T B 954 T B 954 T B 954 T B 954 T T B 1126 T B 1390 T B 954 T B 954 T16 39 T B 954 T B 1126 T B 1999 T B 2000 TG 445 T B 1998 T B 1999 T B 1521 T B 1999 T B 1390 T B 954 T B 1997 T B 1997 T B 1997 T B 1390 T9 29 1B 1999 T B 1998 T B 2000 T B 1390 T B 2000 T B 1390 T B 1997 T B 1126 T3 59 4B 2000 T B 2000 T3 59A 4B 2000 T B 1995 T B 1126 T9 1648M 1B 1995 T B 1126 T9 1649M 2B 1995 T B 1997 T B 2000 T B 1997 T B 2000 T B 1521 T B 1998 T B 1390 T9 1440M 5B 1996 T B 1995 Table 3 - Cross reference list Ironcore to VRI

18 10 VRIOGS Revision A SECTION 8.0 REFERENCE LIST SECONDARY VOLTAGE TO VRI Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 3-18Vdc 3B V 90VA 25Hz 4.2Vdc 7B V 50VA 25Hz 6Vdc 4B V 5VA 25Hz 6Vdc 6B V 45VA 25Hz 12Vdc 3B V 6VA 25Hz 12Vdc 8B V 50VA 50Hz 12Vdc 1B V 100VA 50Hz 12Vdc 1B V 250VA 25Hz 12Vdc 6B V 400VA 25Hz 12-24Vdc 2B V 10VA 50Hz 15Vdc 5B V 25A 50Hz 15.7Vdc 6B V 7.5A 50Hz 18Vdc 1B V 25VA 50Hz 21Vdc 11B V 17A 25Hz 21Vdc 11B 2000M 110V 25A 50Hz 24Vdc 9B Vdc 6A 25Hz 24Vdc 12B Vdc 6A 25Hz 24Vdc 12B V 3A 25Hz 24Vdc 10B V 3A 24Vdc 2B V 8A 50Hz 24Vdc 6B V 10A 50Hz 24Vdc 11B V 20A 50Hz 24Vdc 7B V 260VA 50Hz 24Vdc 10B V 450VA 50Hz 50Vdc 2B Vdc 50VA 50Vdc 4B V 10VA 25Hz 50Vdc 1B V 10VA 25Hz 50Vdc 8B V 50VA 50Hz 50Vdc 9B V 50VA 25Hz 50Vdc 12B V 250VA 25Hz 50Vdc 9B V 250VA 25Hz 50Vdc 5B V 500VA 50Hz 50Vdc 9B V 500VA 25Hz

19 VRIOGS Revision A 11 Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 50Vdc 12B V 1kVA 25Hz 3-18V 5B V 25VA 25Hz 3-18V 7B V 25VA 50Hz 3-18V 12B V 40VA 50Hz 3-18V 3B V 40VA 50Hz 3-18V 1B V 90VA 50Hz 3-18V 3B V 90VA 25Hz 3-18V 4B V 25VA 50Hz 6V 4B Vdc 1.5A 50Hz 6V 5B Vdc 1.5A 50Hz 6-6V 1B V 5VA 25Hz 6-6V 12B V 5VA 50Hz 6-6V 6B V 50VA 25Hz 6-6V 7B V 75VA 25Hz 6-6V 3B V 100VA 50Hz V 1B V 16VA 25Hz V 6B V 20VA 50Hz V 4B V 25VA 25Hz 7-8.5V 8B V 85VA 50Hz 9-12V 10B V 30VA 25Hz 9-12V 11B V 50Hz V 2B V 125VA 50Hz 11-12V 6B V 25VA 50Hz V 11B V 25VA 25Hz V 11B V 37VA 50Hz 21-36V 2B V 50VA 25Hz 24V 3B Vdc 30-34V 5B V 85VA 25Hz B V 25VA 25Hz B V 75VA 25Hz 110V 7B V 5VA 25Hz 110V 10B V 25VA 50Hz V 8B V 30VA 25Hz V 9B V 150VA 25Hz

20 12 VRIOGS Revision A Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 110V 2B V 2kVA 50Hz V 9B V 500VA 50Hz 110V 1B V 750VA 50Hz 110V 8B V 1.5kVA 50Hz 110V 9B V 3kVA 50Hz 110V 7B V 3kVA 50Hz 110V 10B V 5kVA 110V 11B V 6kVA 110V 4B V 1kVA 50Hz 110V 5B V 4kVA 50Hz 120V 6B V 30VA 50Hz 125V 7B V 2kVA 50Hz 125V 8B V 2kVA 50Hz 125V 9B V 3kVA 50Hz 230V 12B V 150VA 50Hz 230V 10B V 3kVA 50Hz 240V 10B V 200mA 250V 10B V 250V 5B V 440V 11B V 4kVA 50Hz 440V 12B V 5kVA 50Hz 460V 8B V 3kVA 25Hz Table 4 - Cross reference list Secondary Voltage

21 VRIOGS Revision A 13 SECTION 9.0 COMPONENT CIRCUITS AND PHOTOS Identifying Name 1B 954 Searchlight Signal INSERT PHOTO

22 14 VRIOGS Revision A Identifying Name 2B 954 Light Signal Dimming INSERT PHOTO

23 VRIOGS Revision A 15 Identifying Name 3B 954 Light Signal Dimming

24 16 VRIOGS Revision A Identifying Name 4B 954 Trickle Charging INSERT PHOTO

25 VRIOGS Revision A 17 Identifying Name 5B 954 Trickle Charging

26 18 VRIOGS Revision A Identifying Name 7B 954 Now Obsolete and see 7B954 Track Feed INSERT PHOTO

27 VRIOGS Revision A 19 Identifying Name 7B 954 Track Feed

28 20 VRIOGS Revision A Identifying Name 8 B 954 Pole Changing

29 VRIOGS Revision A 21 Identifying Name 9B 954 Pole Changing INSERT PHOTO

30 22 VRIOGS Revision A Identifying Name 10B 954 Now Obsolete and see 7B1390 Point Detection

31 VRIOGS Revision A 23 Identifying Name 11B 954 Bell Ringing

32 24 VRIOGS Revision A Identifying Name 12B volt mains INSERT PHOTO

33 VRIOGS Revision A 25 Identifying Name 1B 1126 Indication Light

34 26 VRIOGS Revision A Identifying Name 2B 1126 Transformer

35 VRIOGS Revision A 27 Identifying Name 3B 1126 Transformer

36 28 VRIOGS Revision A Identifying Name 4B 1126 Track Relay Shielding

37 VRIOGS Revision A 29 Identifying Name 5B 1126 Now Obsolete and see 7B 1390 Point Detection

38 30 VRIOGS Revision A Identifying Name 6B 1126 Searchlight Signal

39 VRIOGS Revision A 31 Identifying Name 7B 1126 Trickle Charging

40 32 VRIOGS Revision A Identifying Name 8B 1126 Flashing Light Signal Lamps INSERT PHOTO

41 VRIOGS Revision A 33 Identifying Name 9B volt mains

42 34 VRIOGS Revision A Identifying Name 10B 1126 Line Circuit Isolations

43 VRIOGS Revision A 35 Identifying Name 11B 1126 Searchlight Signal

44 36 VRIOGS Revision A Identifying Name 12B 1126 Now Obsolete and see 1B 1126 Indication Light

45 VRIOGS Revision A 37 Identifying Name 1B 1390 Battery Charging INSERT PHOTO

46 38 VRIOGS Revision A Identifying Name 2B 1390 Flashing Lights INSERT PHOTO

47 VRIOGS Revision A 39 Identifying Name 3B 1390 Battery Charging INSERT PHOTO

48 40 VRIOGS Revision A Identifying Name 4B 1390 Colour Light Signal

49 VRIOGS Revision A 41 Identifying Name 5B 1390 Searchlight Signal

50 42 VRIOGS Revision A Identifying Name 6B 1390 Searchlight Signal

51 VRIOGS Revision A 43 Identifying Name 7B 1390 Point Detection

52 44 VRIOGS Revision A Identifying Name 8B volt mains

53 VRIOGS Revision A 45 Identifying Name 9B volt mains

54 46 VRIOGS Revision A Identifying Name 10B 1390 Colour light signal dimming INSERT PHOTO

55 VRIOGS Revision A 47 Identifying Name 11B 1390 Superseded by 10B 1390 Colour light signal

56 48 VRIOGS Revision A Identifying Name 12B 1390 Battery Charging

57 VRIOGS Revision A 49 Identifying Name 1B volt mains

58 50 VRIOGS Revision A Identifying Name 2B 1521 Mains Isolating INSERT PHOTO

59 VRIOGS Revision A 51 Identifying Name 3B 1521 Trickle Charging INSERT PHOTO

60 52 VRIOGS Revision A Identifying Name 4B volt mains

61 VRIOGS Revision A 53 Identifying Name 5B volt mains INSERT PHOTO

62 54 VRIOGS Revision A Identifying Name 6B 1521 Line Isolating

63 VRIOGS Revision A 55 Identifying Name 7B volt mains INSERT PHOTO

64 56 VRIOGS Revision A Identifying Name 8B volt mains INSERT PHOTO

65 VRIOGS Revision A 57 Identifying Name 9B volt mains INSERT PHOTO

66 58 VRIOGS Revision A Identifying Name 10B volt mains INSERT PHOTO

67 VRIOGS Revision A 59 Identifying Name 11B volt mains INSERT PHOTO

68 60 VRIOGS Revision A Identifying Name 12B volt mains INSERT PHOTO

69 VRIOGS Revision A 61 Identifying Name 1B 1995 Battery Charger

70 62 VRIOGS Revision A Identifying Name 2B 1995 Battery Charger

71 VRIOGS Revision A 63 Identifying Name 3B 1995 Healthy State Indicator

72 64 VRIOGS Revision A Identifying Name 4B 1995 DC voltage sensing relay INSERT CIRCUIT

73 VRIOGS Revision A 65 Identifying Name 5B 1995 Transformer Rectifier INSERT PHOTO

74 66 VRIOGS Revision A Identifying Name 6B 1995 Transformer Rectifier

75 VRIOGS Revision A 67 Identifying Name 9B 1995 Transformer Rectifier-Slugged

76 68 VRIOGS Revision A Identifying Name 1B 1996 Current Sensor INSERT PHOTO

77 VRIOGS Revision A 69 Identifying Name 2B 1996 Track Rectifier-NT

78 70 VRIOGS Revision A Identifying Name 3B 1996 Track Rectifier-BT

79 VRIOGS Revision A 71 Identifying Name 5B 1996 Battery Charger INSERT CIRCUIT

80 72 VRIOGS Revision A Identifying Name 8B 1996 Current Sensor INSERT PHOTO

81 VRIOGS Revision A 73 Identifying Name 9B 1996 Battery Charger INSERT CIRCUIT

82 74 VRIOGS Revision A Identifying Name 10B 1996 Constant Current Source

83 VRIOGS Revision A 75 Identifying Name 12B 1996 Rectifier Unit INSERT CIRCUIT

84 76 VRIOGS Revision A Identifying Name 1B 1997 Contact Protection Unit

85 VRIOGS Revision A 77 Identifying Name 2B 1997 Slow Release Unit INSERT PHOTO

86 78 VRIOGS Revision A Identifying Name 3B 1997 Trickle Charger INSERT PHOTO

87 VRIOGS Revision A 79 Identifying Name 4B 1997 DC Power Off Relay and Tone Unit

88 80 VRIOGS Revision A Identifying Name 5B 1997 Line Surge Suppression Unit INSERT PHOTO

89 VRIOGS Revision A 81 Identifying Name 6B 1997 Line Surge Suppression Unit INSERT PHOTO

90 82 VRIOGS Revision A Identifying Name 7B 1997 Track Feed Unit

91 VRIOGS Revision A 83 Identifying Name 8B 1997 Transformer Rectifier

92 84 VRIOGS Revision A Identifying Name 9B 1997 Transformer Rectifier

93 VRIOGS Revision A 85 Identifying Name 10B 1997 Negative Regulator

94 86 VRIOGS Revision A Identifying Name 11B 1997 Approach Indicator

95 VRIOGS Revision A 87 Identifying Name 12B 1997 Stabilised Power Supply CSEE Track Circuit

96 88 VRIOGS Revision A Identifying Name 1B 1998 Battery Charger

97 VRIOGS Revision A 89 Identifying Name 2B 1998 LED Indicator Unit

98 90 VRIOGS Revision A Identifying Name 3B 1998 LED Signal Repeater

99 VRIOGS Revision A 91 Identifying Name 4B 1998 Reactive Transformer Rectifier

100 92 VRIOGS Revision A Identifying Name 5B 1998 Superseded by 9B 1998 Flasher Card

101 VRIOGS Revision A 93 Identifying Name 6B 1998 DC Supply Unit

102 94 VRIOGS Revision A Identifying Name 7B 1998 DC Filtered Power Supply Unit

103 VRIOGS Revision A 95 Identifying Name 8B 1998 LED Indicator Signal

104 96 VRIOGS Revision A Identifying Name 9B 1998 Flasher Card

105 VRIOGS Revision A 97 Identifying Name 10B 1998 DC Filtered Power Supply Unit

106 98 VRIOGS Revision A Identifying Name 11B 1998 LED Indicator Points

107 VRIOGS Revision A 99 Identifying Name 12B 1998 DC Smoother Power Supply

108 100 VRIOGS Revision A Identifying Name 1B 1999 Transformer Rectifier

109 VRIOGS Revision A 101 Identifying Name 2B 1999 DC-DC Converter

110 102 VRIOGS Revision A Identifying Name 3B 1999 Transistorised Inverter

111 VRIOGS Revision A 103 Identifying Name 4B 1999 Track Feed Unit

112 104 VRIOGS Revision A Identifying Name 5B 1999 Slow Release Unit for MSRA Relay

113 VRIOGS Revision A 105 Identifying Name 6B 1999 Static Flasher Unit

114 106 VRIOGS Revision A Identifying Name 7B 1999 Terminating Junction for unused 1B2000 Unit

115 VRIOGS Revision A 107 Identifying Name 8B 1999 Now Obsolete and see 9B 1999 Transformer Rectifier

116 108 VRIOGS Revision A Identifying Name 9B 1999 Transformer Rectifier

117 VRIOGS Revision A 109 Identifying Name 10B 1999 Transformer Rectifier

118 110 VRIOGS Revision A Identifying Name 11B 1999 Slow Release Unit for 2-MBA relays

119 VRIOGS Revision A 111 Identifying Name 12B 1999 Bridge Rectifier

120 112 VRIOGS Revision A Identifying Name 1B 2000 Transformer Rectifier

121 VRIOGS Revision A 113 Identifying Name 2B 2000 Transformer Rectifier INSERT PHOTO

122 114 VRIOGS Revision A Identifying Name 3B 2000 Transformer Rectifier

123 VRIOGS Revision A 115 Identifying Name 4B 2000 Transistorised Inverter

124 116 VRIOGS Revision A Identifying Name 5B 2000 Transistorised Inverter

125 VRIOGS Revision A 117 Identifying Name 6B 2000 Battery Charger

126 118 VRIOGS Revision A Identifying Name 7B 2000 Time Delay Unit INSERT PHOTO

127 VRIOGS Revision A 119 Identifying Name 8B 2000 Time Delay Unit INSERT PHOTO

128 120 VRIOGS Revision A Identifying Name 9B 2000 Twin Time Delay Unit

129 VRIOGS Revision A 121 Identifying Name 10B 2000 Static Flasher Unit

130 122 VRIOGS Revision A Identifying Name 11B 2000 Transformer Rectifier for Boom Barriers

131 VRIOGS Revision A 123 Identifying Name 11B 2000 M Heavy Duty Transformer Rectifier for Boom Barriers

132 124 VRIOGS Revision A Identifying Name 12B 2000 Transformer Rectifier

133 VRIOGS Revision A 125 SECTION 10.0 REFERENCES 1. ARO type approved signal equipment list

Engineering Waiver Management

Engineering Waiver Management Division / Business Unit: Function: Document Type: Enterprise Services All Disciplines Procedure Engineering Waiver Management Applicability ARTC Network Wide SMS Publication Requirement Internal / External

More information

Inspection and Testing of Signalling - Roles, Responsibilities & Authorities

Inspection and Testing of Signalling - Roles, Responsibilities & Authorities Discipline: Engineering (Signalling) Category: Standard Inspection and Testing of Signalling - Roles, Responsibilities & Authorities ESC-21-01 Applicability ARTC Network Wide CRIA (NSW CRN) Primary Source

More information

Buck & Boost Transformer Installation Instructions

Buck & Boost Transformer Installation Instructions Buck & Boost Installation Instructions 120 V x 240 V - 12/24 V Class 7414 Introduction This manual provides installation, operation, and maintenance instructions for the 2847 Buck & Boost transformer,

More information

Railway Interoperability and Safety Committee. Working document

Railway Interoperability and Safety Committee. Working document 08/57-ST12 RISC 62 Version EN01 Origin EN 06.10.2011 Status: NA Railway Interoperability and Safety Committee Working document Draft Commission Decision amending Commission Decisions 2006/679/EC and 2006/860/EC

More information

Australian Standard. Clinical investigations of medical devices for human subjects. Part 1: General requirements AS ISO ISO :2003

Australian Standard. Clinical investigations of medical devices for human subjects. Part 1: General requirements AS ISO ISO :2003 AS ISO 14155.1 2004 ISO 14155-1:2003 AS ISO 14155.1 2004 Australian Standard Clinical investigations of medical devices for human subjects Part 1: General requirements This Australian Standard was prepared

More information

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 15 KW, 50/60 AND 400 Hz MEP-804A (50/60 Hz) 6115-01-274-7388 MEP-814A (400 Hz) 6115-01-274-7393

More information

COMMISSION DIRECTIVE 2011/18/EU

COMMISSION DIRECTIVE 2011/18/EU 2.3.2011 Official Journal of the European Union L 57/21 DIRECTIVES COMMISSION DIRECTIVE 2011/18/EU of 1 March 2011 amending Annexes II, V and VI to Directive 2008/57/EC of the European Parliament and of

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4308:2008 AS/NZS 4308:2008 Australian/New Zealand Standard Procedures for specimen collection and the detection and quantitation of drugs of abuse in urine AS/NZS 4308:2008 This Joint Australian/New

More information

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL 1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL Bozeman Manufacturing Facility Bozeman, MT USA (303) 987-8000 FAX: (406) 585-9219 www.mesalabs.com Omaha Manufacturing Facility Omaha,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3003:2003 Australian/New Zealand Standard Electrical installations Patient areas of hospitals, medical and dental practices and dialyzing locations PREPARATION OF JOINT AUSTRALIAN/NEW ZEALAND STANDARDS

More information

49469-IND: Mumbai Metro Rail Investment Project. 12 June 2018, 15:00 hours Indian Standard Time (IST)

49469-IND: Mumbai Metro Rail Investment Project. 12 June 2018, 15:00 hours Indian Standard Time (IST) Invitation for Bids Date: 18 April 2018 Loan No. and Title: Contract No. and Title: Deadline for Submission of Bids: 49469-IND: Mumbai Metro Rail Investment Project MRS1: Design, Manufacture, Supply, Testing,

More information

TECHNICAL MANUAL. DISTRIBUTION STATEMENT A : Approved for public release; distribution is unlimite.

TECHNICAL MANUAL. DISTRIBUTION STATEMENT A : Approved for public release; distribution is unlimite. TECHNICAL MANUAL OPERATOR S MANUAL GENERATOR SET SKID MOUNTED, TACTICAL QUIET 5 KW, 60 AND 400 HZ MEP-802A (60 HZ) 6115-01-274-7387 MEP-812A (400 HZ) 6115-01-274-7391 DISTRIBUTION STATEMENT A : Approved

More information

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model EZTest Incubator OPERATION MANUAL 10 Evergreen Drive Bozeman, MT 59715 USA (303) 987-8000 www.mesalabs.com 16 1 This page intentionally blank. 2 15 This page intentionally blank. Table of Contents Introduction

More information

OPERATOR S MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET

OPERATOR S MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET AIR FORCE TO 35C2 3-444 11 MARINE CORPS TM 09244A/09245A 10/1 TECHNICAL MANUAL OPERATOR S MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 60 KW, 50/60 AND 400 HZ MEP-806A (50/60 HZ) 6115-01-274-7390

More information

A. General provisions and other electrical systems are specified in other Sections of Division 26.

A. General provisions and other electrical systems are specified in other Sections of Division 26. PART 1: GENERAL 1.01 DESCRIPTION: A. General provisions and other electrical systems are specified in other Sections of Division 26. B. Commissioning is an ongoing process and shall be performed throughout

More information

B. All of the documents in this RFP form the Basis-of-Design for this project.

B. All of the documents in this RFP form the Basis-of-Design for this project. SECTION 01 91 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 13940 First edition 2015-12-15 Health informatics System of concepts to support continuity of care Informatique de santé Système de concepts en appui de la continuité des soins

More information

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation Document No. 540-1027 Siemens TEC Unit Vent 0-10V Output Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2281, 2283, 2284, 2286, 2287

More information

PRODUCTION PERMIT/ CONCESSION FORM GUIDELINES

PRODUCTION PERMIT/ CONCESSION FORM GUIDELINES PRODUCTION PERMIT/ CONCESSION FORM GUIDELINES Issue 05 9 th April 2018 A white paper issued by: Siemens. Siemens AG 2016. All rights reserved Contents 1 Purpose 3 2 Scope of Applicability 3 3 Definitions

More information

Solar Homes and Communities Plan Residential application for pre-approval

Solar Homes and Communities Plan Residential application for pre-approval Solar Homes and Communities Plan Residential application for pre-approval Step 1 Read the Solar Homes and Communities Plan Guidelines for residential applicants to check if you are eligible. Step 2 Obtain

More information

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES TESTING APPLICATION STANDARD (TAS) 201-94 IMPACT TEST PROCEDURES 1. 2. Scope: 1.1 This protocol covers procedures for conducting the impact test of materials as required by Section 1626 of the Florida

More information

Guidelines on the Keeping of Records in Respect of Medicinal Products when Conducting a Retail Pharmacy Business

Guidelines on the Keeping of Records in Respect of Medicinal Products when Conducting a Retail Pharmacy Business Guidelines on the Keeping of Records in Respect of Medicinal Products when Conducting a Retail Pharmacy Business to facilitate compliance with Regulation 12 of the Regulation of Retail Pharmacy Businesses

More information

AMENDMENT OF SOLICITATION

AMENDMENT OF SOLICITATION 1. SOLICITATION NO.: 2. AMENDMENT NO.: DALLAS AREA RAPID TRANSIT DALLAS, TEXAS AMENDMENT OF SOLICITATION 3. EFFECTIVE DATE: 4. BRIEF SOLICITATION DESCRIPTION: B-1022113 1 September 21, 2012 5. REVISED

More information

Declaration of Classification ValiSpore Incubator Manual

Declaration of Classification ValiSpore Incubator Manual alisafe Declaration of Classification ValiSpore Incubator Manual I hereby confirm that the Valisafe chemical indicators used to monitor steam sterilization are an accessory to a class 1 medical device

More information

Miscellaneous Publication

Miscellaneous Publication SA MP 101:2017 SA MP 101:2017 Miscellaneous Publication On-site domestic wastewater treatment Conformity assessment requirements for AS 1546.3 and AS 1546.4 This Miscellaneous Publication was prepared

More information

AS/NZS :2014. Single-use medical examination gloves AS/NZS :2014

AS/NZS :2014. Single-use medical examination gloves AS/NZS :2014 Australian/New Zealand Standard AS/NZS 4011.1:2014 (ISO 11193-1:2008, MOD) Single-use medical examination gloves Part 1: Specification for gloves made from rubber latex or rubber solution Superseding AS/NZS

More information

Australia s National Guidelines and Procedures for Approving Participation in Joint Implementation Projects

Australia s National Guidelines and Procedures for Approving Participation in Joint Implementation Projects Australia s National Guidelines and Procedures for Approving Participation in Joint Implementation Projects March 2010 Version 1.2 Contacting the National Authority for the CDM and JI For information about

More information

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1 OPERATOR S, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL OPERATING INSTRUCTIONS 2-1 OPERATOR TROUBLESHOOTING 3-3 UNIT LEVEL PMCS 4-7 UNIT LEVEL TROUBLESHOOTING 4-12 UNIT MAINTENANCE PROCEDURES 4-27 DIRECT

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4501.1:2008 CEN/TR 15321:2006 AS/NZS 4501.1:2008 Australian/New Zealand Standard Occupational protective clothing Part 1: Guidelines on the selection, use, care and maintenance of protective clothing

More information

REQUESTING QUALIFICATIONS FOR PROFESSIONAL SERVICES

REQUESTING QUALIFICATIONS FOR PROFESSIONAL SERVICES STATE OF FLORIDA, DEPARTMENT OF MILITARY AFFAIRS CONSTRUCTION & FACILITY MANAGEMENT OFFICE PUBLIC ANNOUNCEMENT REQUESTING QUALIFICATIONS FOR PROFESSIONAL SERVICES For PROJECT NUMBER: FEA 1802 Multi-Facility

More information

Pre-registration. e-portfolio

Pre-registration. e-portfolio Pre-registration e-portfolio 2013 2014 Contents E-portfolio Introduction 3 Performance Standards 5 Page Appendix SWOT analysis 1 Start of training plan 2 13 week plan 3 26 week plan 4 39 week plan 5 Appraisal

More information

Clinical Coding Policy

Clinical Coding Policy Clinical Coding Policy Document Summary This policy document sets out the Trust s expectations on the management of clinical coding DOCUMENT NUMBER POL/002/093 DATE RATIFIED 9 December 2013 DATE IMPLEMENTED

More information

Non Medical Prescribing Policy

Non Medical Prescribing Policy Non Medical Prescribing Policy Author: Sponsor/Executive: Responsible committee: Ratified by: Consultation & Approval: (Committee/Groups which signed off the policy, including date) This document replaces:

More information

NZQA Expiring unit standard version 3 Page 1 of 6

NZQA Expiring unit standard version 3 Page 1 of 6 Page 1 of 6 Title Describe the electricity metering Codes of Practice Level 4 Credits 10 Purpose People credited with this unit standard are able to describe the: Code of Practice 10.1 Metering installations;

More information

City of Puyallup City-Owned Fiber Infrastructure Evaluation Project

City of Puyallup City-Owned Fiber Infrastructure Evaluation Project REQUEST FOR PROPOSALS City of Puyallup City-Owned Fiber Infrastructure Evaluation Project Due Date: Friday, September 29, 2017; No later than 4:00 PM City of Puyallup 333 S Meridian Puyallup, WA 98371

More information

*PLEASE NOTE NEW SIZES TO ADVERTISING SPECS ON PAGE 5

*PLEASE NOTE NEW SIZES TO ADVERTISING SPECS ON PAGE 5 2016 ADVERTISING RATES* *PLEASE NOTE NEW SIZES TO ADVERTISING SPECS ON PAGE 5 THE AUSTRALIAN NURSING & MIDWIFERY JOURNAL (ANMJ) IS AUSTRALIA S LEADING NURSING JOURNAL, REACHING MORE THAN 140,000* NURSES

More information

TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTS)

TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTS) *TM 9-6115-646-14&P TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTS) POWER UNIT PU-495A/G (NSN 6115-00-394-9575) AND

More information

RG 102 Accreditation for the Inspection of Non-public High Voltage Electrical Systems

RG 102 Accreditation for the Inspection of Non-public High Voltage Electrical Systems This publication contains policy, recommendations and guidance applicable to UKAS accredited inspection bodies RG 102 Accreditation for the Inspection of Non-public High Voltage Electrical Systems Contents

More information

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL AIR CONDITIONER, HORIZONTAL, COMPACT, 36,000 BTU/HR, MULTI-POWER INPUT 208V, 3 PHASE, 50/60/400 HZ MODEL MH-40-MP

More information

PART II: GENERAL CONDITIONS APPLICCABLE TO GRANTS FROM THE NORWEGIAN MINISTRY OF FOREIGN AFFAIRS

PART II: GENERAL CONDITIONS APPLICCABLE TO GRANTS FROM THE NORWEGIAN MINISTRY OF FOREIGN AFFAIRS PART II: GENERAL CONDITIONS APPLICCABLE TO GRANTS FROM THE NORWEGIAN MINISTRY OF FOREIGN AFFAIRS TABLE OF CONTENTS 1 IMPLEMENTATION PLAN AND BUDGET... 2 2 PROGRESS REPORT... 2 3 FINANCIAL REPORT... 2 4

More information

Position description. Classification Registered Nurse Grade 3

Position description. Classification Registered Nurse Grade 3 Position (CDNPC) Classification Registered Nurse Grade 3 Award Reports to Direct reports Key relationships Hours of Work Position summary Nurses and Midwives (Victorian Public Health Sector) (Single Interest

More information

Agreement. Between: The Research Foundation, Cerebral Palsy Alliance. And: (Name of Institution) Project: (Name of project)

Agreement. Between: The Research Foundation, Cerebral Palsy Alliance. And: (Name of Institution) Project: (Name of project) Agreement Between: The Research Foundation, Cerebral Palsy Alliance And: (Name of Institution) Project: (Name of project) Contents 1. Defined meanings... 1 2. Administration of Award... 1 3. Funding...

More information

Medication Management Policy and Procedures

Medication Management Policy and Procedures POLICY STATEMENT This policy establishes guidelines for ensuring safe and correct management of client medications in accordance with legislative and regulatory requirements and professional practice competency

More information

REQUESTING QUALIFICATIONS FOR PROFESSIONAL DESIGN SERVICES

REQUESTING QUALIFICATIONS FOR PROFESSIONAL DESIGN SERVICES STATE OF FLORIDA, DEPARTMENT OF MILITARY AFFAIRS CONSTRUCTION & FACILITY MANAGEMENT OFFICE PUBLIC ANNOUNCEMENT REQUESTING QUALIFICATIONS FOR PROFESSIONAL DESIGN SERVICES For PROJECT NUMBER: 212060 BROOKSVILLE

More information

Frequently Asked Questions (FAQs) regarding ISO/IEC 17025:2017 and the transition of accreditation from the previous version of the Standard

Frequently Asked Questions (FAQs) regarding ISO/IEC 17025:2017 and the transition of accreditation from the previous version of the Standard Frequently Asked Questions (FAQs) regarding ISO/IEC 17025:2017 and the transition of accreditation from the previous version of the Standard Issue Date: 10 July 2018 General Questions 1. When was the new

More information

ANCILLARY EQUIPMENT FOR: PERSONNEL TROOP PARACHUTE SYSTEM

ANCILLARY EQUIPMENT FOR: PERSONNEL TROOP PARACHUTE SYSTEM *TM 10-1670-299-20&P TO 14D1-2-470-2 NAVAIR 13-1-41 UNIT MAINTENANCE MANUAL, INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST (RPSTL) FOR ANCILLARY EQUIPMENT FOR: PERSONNEL TROOP PARACHUTE SYSTEM CASE, PARACHUTISTS,

More information

PART V PROPOSAL REQUIREMENTS

PART V PROPOSAL REQUIREMENTS PART V PROPOSAL REQUIREMENTS SECTION TITLE K L M Proposal Content Cost Information Submission of Proposal 38 SECTION K PROPOSAL CONTENT K.1 GENERAL REQUIREMENTS A. The requirements included in this Section

More information

MAGTFTC MCAGCC GUIDANCE FOR DD FORM 67 (FORM PROCESSING ACTION REQUEST )

MAGTFTC MCAGCC GUIDANCE FOR DD FORM 67 (FORM PROCESSING ACTION REQUEST ) MAGTFTC MCAGCC GUIDANCE FOR DD FORM 67 (FORM PROCESSING ACTION REQUEST ) ITEM NUMBER INSTRUCTIONS 1. DATE OF REQUEST Enter the date of the form request: YYYYMMDD 2. FROM Enter the complete mailing address

More information

ARMY TB

ARMY TB ARMY TB 9-6115-672-24 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 60kW, 50/60 AND 400 Hz MEP-806B AND MEP-816B PROCURED UNDER CONTRACT DAAK01-96-D-0062

More information

Level 2 NVQ Diploma in Heating and Ventilating - Ductwork Installation ( )

Level 2 NVQ Diploma in Heating and Ventilating - Ductwork Installation ( ) Level 2 NVQ Diploma in Heating and Ventilating - Ductwork Installation (6188-21) Candidate performance evidence logbook 600/0144/6 www.cityandguilds.com February 2012 Version 1.0 About City & Guilds As

More information

Interim Australian/New Zealand Standard

Interim Australian/New Zealand Standard A1 AS/NZS 5911(Int):2005 Expires 17 March 2009 (Incorporating Amendment No. 1) AS/NZS 5911(Int):2005 Interim Australian/New Zealand Standard General guidelines on the verification, validation and assurance

More information

NOTE ON PERFORMANCE TESTING

NOTE ON PERFORMANCE TESTING NOTE ON PERFORMANCE TESTING Performance Profile Sheet(s) are included in a format that can be easily photocop ied for each trainee. Performance tests are designed to mea sure competency in the s taught

More information

MMRCL Recruitment Advertisement

MMRCL Recruitment Advertisement MUMBAI METRO RAIL CORPORATION LIMITED (A JV company of Govt. of India and Govt. of Maharashtra) NaMTTRI Building, Plot # R-13, E Block, Bandra-Kurla Complex, Bandra (E), Mumbai - 400 051. Website: www.mmrcl.com

More information

Documents and Records Management ISO 14001:

Documents and Records Management ISO 14001: Document Number: PRO-008 Revision Number: 6 1. PURPOSE: This procedure describes the methods for environmental document and records management including the document numbering system, document control

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4815:2001 AS/NZS 4815 Australian/New Zealand Standard Office-based health care facilities not involved in complex patient procedures and processes Cleaning, disinfecting and sterilizing reusable

More information

OH-58A/C AIRCRAFT PHASED MAINTENANCE CHECKLIST

OH-58A/C AIRCRAFT PHASED MAINTENANCE CHECKLIST TECHNICAL MANUAL OH-58A/C AIRCRAFT PHASED MAINTENANCE CHECKLIST This manual supersedes those portions of TM 55-1520-228-PMS, 24 September 1976, that pertain to Periodic Inspections. HEADQUARTERS, DEPARTMENT

More information

Fiscal Year 2018 Competitive Funding Opportunity; Grants for Buses and Bus Facilities Infrastructure Investment Program

Fiscal Year 2018 Competitive Funding Opportunity; Grants for Buses and Bus Facilities Infrastructure Investment Program This document is scheduled to be published in the Federal Register on 06/25/2018 and available online at https://federalregister.gov/d/2018-13554, and on FDsys.gov DEPARTMENT OF TRANSPORTATION Federal

More information

INFORMATION BULLETIN OPERATING PERMITS

INFORMATION BULLETIN OPERATING PERMITS OPERATING PERMITS This guide supplements Directive NO: D-E3 070801 7 revised on May 4, 2015. The following document provides guidance on the application of policy for BCSA. Please check with municipal

More information

Oracle. Human Capital Management Cloud Using Volunteering. Release 13 (update 18A)

Oracle. Human Capital Management Cloud Using Volunteering. Release 13 (update 18A) Oracle Human Capital Management Cloud Release 13 (update 18A) Release 13 (update 18A) Part Number E92269-02 Copyright 2011-2018, Oracle and/or its affiliates. All rights reserved. Author: Lakshmi VR This

More information

Techstream ECU Flash Reprogramming Procedure

Techstream ECU Flash Reprogramming Procedure T-SB-0012-13 January 29, 2013 Service Category Engine/Hybrid System Section Engine Control Market USA Applicability YEAR(S) MODEL(S) ADDITIONAL INFORMATION 2001 2014 4Runner, Avalon, Avalon HV, Camry,

More information

OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL FOR MULTIPLEXER SET AN/FCC-97 (NSN )

OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL FOR MULTIPLEXER SET AN/FCC-97 (NSN ) ARMY TM 11-5805-694-14 AIR FORCE TO 31W2-4-287-1 OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL FOR MULTIPLEXER SET AN/FCC-97 (NSN 5805-01-0308) This copy is a reprint

More information

Medical Grade Power Strips

Medical Grade Power Strips Product Bulletin for Medical Grade Power Strips For use in Patient Care Areas of Health Care Facilities Conforms to UL 60601-1, UL 60950-1 and UL 1363A Leviton s family of medical-grade power strips are

More information

ARMY AH-64A HELICOPTER

ARMY AH-64A HELICOPTER TECHNICAL MANUAL PHASED MAINTENANCE INSPECTION CHECKLIST FOR ARMY AH-64A HELICOPTER Approved for public release; distribution is unlimited TM 1-1520-238-PM dated TBD supersedes TM 1-1520-238-PM dated 30

More information

Association of Mining and Exploration Companies (Inc)

Association of Mining and Exploration Companies (Inc) 1st June 2012 Chief Executive Officer Queensland Competition Authority GPO Box 2257 BRISBANE QLD 4001 Dear Sir Queensland Rail 2012 Draft Access Undertaking (DAU) Thank you for the opportunity to provide

More information

Easylink to Square D Module

Easylink to Square D Module Document o. 587-326 Easylink to Square D Module Product Description The Easylink Module mounts in an enclosure (P/ 587-300, 115 Vac or P/ 587-295, 230 Vac). Once installed, the Easylink Module is positioned

More information

TRIP OF YALLOURN POWER STATION NO KV BUSBAR ON 6 DECEMBER 2015

TRIP OF YALLOURN POWER STATION NO KV BUSBAR ON 6 DECEMBER 2015 TRIP OF YALLOURN POWER STATION NO.2 220 KV BUSBAR ON 6 DECEMBER 2015 AN AEMO POWER SYSTEM OPERATING INCIDENT REPORT FOR THE NATIONAL ELECTRICITY MARKET Published: March 2016 VERSION RELEASE HISTORY VERSION

More information

CAP REGULATION 1-2 NATIONAL HEADQUARTERS CIVIL AIR PATROL 07 NOVEMBER 2016 CIVIL AIR PATROL STANDARDS PUBLICATIONS MANAGEMENT

CAP REGULATION 1-2 NATIONAL HEADQUARTERS CIVIL AIR PATROL 07 NOVEMBER 2016 CIVIL AIR PATROL STANDARDS PUBLICATIONS MANAGEMENT NATIONAL HEADQUARTERS CIVIL AIR PATROL CAP REGULATION 1-2 07 NOVEMBER 2016 CIVIL AIR PATROL STANDARDS PUBLICATIONS MANAGEMENT This regulation implements federal statutes, United States Air Force policy,

More information

COMPRESSED NATURAL GAS UTILITY TRUCK BODIES

COMPRESSED NATURAL GAS UTILITY TRUCK BODIES REQUEST FOR PROPOSALS COMPRESSED NATURAL GAS UTILITY TRUCK BODIES April 2018 CITY OF SAN MATEO Public Works Department 330 West 20 th Avenue San Mateo, CA 94403 650/522-7300 650/522-7301 (fax) ***** 1

More information

TM &P TECHNICAL MANUAL INTRODUCTION 1-1 OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TM &P TECHNICAL MANUAL INTRODUCTION 1-1 OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TECHNICAL MANUAL OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FOR WATER QUALITY ANALYSIS SET PREVENTIVE MEDICINE NSN 6630-01-367-9402 (EIC) ZGF INTRODUCTION

More information

Proposal Form for Standards Development Projects. Version: 2.0 Issued: March 2010

Proposal Form for Standards Development Projects. Version: 2.0 Issued: March 2010 Proposal Form for Standards Development Projects Version: 2.0 Issued: March 2010 GUIDANCE How do I use this form? Use the Tab key to move to the next field and Shift+Tab to go back to the previous field.

More information

Technical specifications for Interoperability (TSIs)

Technical specifications for Interoperability (TSIs) Technical specifications for Interoperability (TSIs) 1. Content and Scope 2. Major differences between a TSI and UIC leaflets / standards 3. When do they need to be applied? 9 March 2011 IPA project -

More information

Item No. Description Part No.

Item No. Description Part No. MONITRON II Boiler Replacement Parts List LISTED 89C4 Electric Hot Water Boiler This parts list must be left with owner, hung on or adjacent to the boiler. Owner should retain parts list for future reference.

More information

SUP 08 Operational procedures for Medical Gas Pipeline Systems (MGPS) Unified procedures for use within NHS Scotland

SUP 08 Operational procedures for Medical Gas Pipeline Systems (MGPS) Unified procedures for use within NHS Scotland SUP 08 Operational procedures for Medical Gas Pipeline Systems (MGPS) Unified procedures for use within NHS Scotland May 2015 Contents Page Acknowledgements... 4 Introduction... 5 1. Aim and scope... 6

More information

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A [INCH-POUND] A-A-55571/5F 11 December 2014 SUPERSEDING A-A-55571/5E 7 May 2009 COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES

More information

REPORT. Unit # 1, Street Surrey, British Columbia, V3W 4E6, Canada

REPORT. Unit # 1, Street Surrey, British Columbia, V3W 4E6, Canada REPORT For Acura Embedded Systems Inc. Unit # 1, 7711-128 Street Surrey, British Columbia, V3W 4E6, Canada Date: August 8, 2011 Report No.: 10052-1S Revision No.: 0 Project No.: 10052 Equipment: Mobile

More information

FILING OF ANNUAL FINANCIAL STATEMENTS TO THE CIPC IN XBRL

FILING OF ANNUAL FINANCIAL STATEMENTS TO THE CIPC IN XBRL FILING OF ANNUAL FINANCIAL STATEMENTS TO THE CIPC IN XBRL Filers Guidelines: Business Aspects Author: Hennie Viljoen XBRL Programme Manager: CIPC This document provides General Information and Guidelines

More information

Clinical Documentation

Clinical Documentation Approved by: Chief Operating Officer; and Chief Medical Officer Clinical Documentation Corporate Policy & Procedures Manual Number: III-120 Date Approved January 4, 2018 Date Effective February 9, 2018

More information

AS/NZS 1336:1997 AS/NZS

AS/NZS 1336:1997 AS/NZS AS/NZS 1336:2014 Australian/New Zealand Standard Eye and face protection Guidelines Superseding AS/NZS 1336:1997 AS/NZS 1336:2014 AS/NZS 1336:2014 This joint Australian/New Zealand standard was prepared

More information

DEPARTMENT OF DEFENSE INTERFACE STANDARD BI-LEVEL IMAGE COMPRESSION FOR THE NATIONAL IMAGERY TRANSMISSION FORMAT STANDARD

DEPARTMENT OF DEFENSE INTERFACE STANDARD BI-LEVEL IMAGE COMPRESSION FOR THE NATIONAL IMAGERY TRANSMISSION FORMAT STANDARD NOTICE OF CHANGE NOT MEASUREMENT SENSITIVE MIL-STD-188-196 NOTICE 1 27 June 1996 DEPARTMENT OF DEFENSE INTERFACE STANDARD BI-LEVEL IMAGE COMPRESSION FOR THE NATIONAL IMAGERY TRANSMISSION FORMAT STANDARD

More information

OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING LASER: M83 (NSN ) FOR

OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING LASER: M83 (NSN ) FOR Supersedes copy dated 18 October 1984 OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING LASER: M83 (NSN 1265-01-158-4560) FOR M2/M3 FIGHTING VEHICLES DISTRIBUTION

More information

GUIDELINES FOR THE USE OF ASSISTIVE TECHNOLOGY EQUIPMENT IN COMMUNITY INPATIENT UNITS

GUIDELINES FOR THE USE OF ASSISTIVE TECHNOLOGY EQUIPMENT IN COMMUNITY INPATIENT UNITS GUIDELINES FOR THE USE OF ASSISTIVE TECHNOLOGY EQUIPMENT IN COMMUNITY INPATIENT UNITS Guideline Reference: 1666 Version: 2.1 Status: Adopted Type: Clinical Guideline Guideline applies to (Staff Group)

More information

OPERATOR, ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS

OPERATOR, ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS WIND MEASURING SET AN/PMQ-3A (NSN 6660-515-4339) This

More information

NATIONAL PATIENT REPORTED OUTCOME MEASURES (PROMS) SUPPLIER ACCREDITATION PROCESS

NATIONAL PATIENT REPORTED OUTCOME MEASURES (PROMS) SUPPLIER ACCREDITATION PROCESS NATIONAL PATIENT REPORTED OUTCOME MEASURES (PROMS) SUPPLIER ACCREDITATION PROCESS September 2017 1 INFORMATION READER BOX Directorate Medical Operations and Information Specialised Commissioning Nursing

More information

Automated License Plate Reader (ALPR) System. City of Coquitlam. Request for Proposals RFP No Issue Date: January 25, 2017

Automated License Plate Reader (ALPR) System. City of Coquitlam. Request for Proposals RFP No Issue Date: January 25, 2017 Request for Proposals RFP No. 17-01-06 Automated License Plate Reader (ALPR) System Issue Date: January 25, 2017 File #: 03-1220-20/17-01-06/1 Doc #: 2519682.v1 RFP No. 17-01-06 Automated License Plate

More information

The Director is the legally responsible person must manage the RTO s compliance with the Standards for RTO s 2015.

The Director is the legally responsible person must manage the RTO s compliance with the Standards for RTO s 2015. Duty Statement - Director The Director is the legally responsible person must manage the RTO s compliance with the Standards for RTO s 2015. RTO compliance delegation The Director may delegate their key

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-31239-8 Edition 1 and IEEE amdt 1 IEEE Std 1584-2002 and IEEE Std 1584a-2004 (amdt to IEEE Std 1584-2002) SOUTH AFRICAN NATIONAL STANDARD IEEE guide for performing arc-flash hazard calculations

More information

REQUEST FOR PROPOSALS

REQUEST FOR PROPOSALS REQUEST FOR PROPOSALS RFP # 17-02-04 Window & Portable AC Units & Parts PART II The Houston Independent School District ( HISD and/or the District ) is soliciting proposals for Window & Portable AC Units

More information

CHESAPEAKE BAY BRIDGE AND TUNNEL DISTRICT PARALLEL THIMBLE SHOAL TUNNEL REQUEST FOR QUALIFICATIONS #PTST-15-1

CHESAPEAKE BAY BRIDGE AND TUNNEL DISTRICT PARALLEL THIMBLE SHOAL TUNNEL REQUEST FOR QUALIFICATIONS #PTST-15-1 CHESAPEAKE BAY BRIDGE AND TUNNEL DISTRICT PARALLEL THIMBLE SHOAL TUNNEL REQUEST FOR QUALIFICATIONS #PTST-15-1 TO: FROM: All Offerors Chesapeake Bay Bridge and Tunnel District SUBJECT: Addendum No. 1 Request

More information

TANZANIA CIVIL AVIATION AUTHORITY AERODROMES AND AIR NAVIGATION SERVICES. Foreword

TANZANIA CIVIL AVIATION AUTHORITY AERODROMES AND AIR NAVIGATION SERVICES. Foreword AERODROMES AND AIR NAVIGATION SERVICES Revision: 1 Title: ANS Inspector Handbook Page 1 of 62 Foreword The Civil Aviation safety oversight program has been implemented to promote and ensure conformance

More information

Assessing Benefits from the Regional Rail Link Project. Independent assurance report to Parliament. May : 18

Assessing Benefits from the Regional Rail Link Project. Independent assurance report to Parliament. May : 18 Assessing Benefits from the Regional Rail Link Project May 2018 Independent assurance report to Parliament 2017 18: 18 Assessing Benefits from the Regional Rail Link Project Independent assurance report

More information

DMTF Standards Incubation Process

DMTF Standards Incubation Process 1 2 3 4 Document Number: DSP4008 Date: 2010-11-19 Version: 1.2.0 5 6 7 8 9 Document Type: Process Document Status: DMTF Informational Document Language: en-us 10 DSP4008 11 12 Copyright Notice Copyright

More information

Document Title: Study Data SOP (CRFs and Source Data)

Document Title: Study Data SOP (CRFs and Source Data) Document Title: Study Data SOP (CRFs and Source Data) Document Number: SOP047 Staff involved in development: Job titles only Document author/owner: Directorate: Department: For use by: RM&G Manager, R&D

More information

Machine Gun Barrel Research Records, Carnegie Institution of Washington Geophysical Laboratory Archives Washington, DC

Machine Gun Barrel Research Records, Carnegie Institution of Washington Geophysical Laboratory Archives Washington, DC Machine Gun Barrel Research Records, 1941-1945 Carnegie Institution of Washington Geophysical Laboratory Archives Washington, DC Finding aid written by: Joseph Neumann September 2008 Machine Gun Barrel

More information

Level 3 NVQ Diploma in Pharmacy Service Skills (QCF) ( )

Level 3 NVQ Diploma in Pharmacy Service Skills (QCF) ( ) Level 3 NVQ Diploma in Pharmacy Service Skills (QCF) (5355-03) Qualification handbook for centres 500/9576/6 www.cityandguilds.com September 2010 Version 3.1 (August 2013) About City & Guilds City & Guilds

More information

CNAS-RC07. Rules for the Accreditation of Certification Bodies with Foreign Locations

CNAS-RC07. Rules for the Accreditation of Certification Bodies with Foreign Locations CNAS-RC07 Rules for the Accreditation of Certification Bodies with Foreign Locations CNAS CNAS-RC07:2014 Page 1 of 7 Foreword This document is developed by CNAS. This document specifies the basic rules

More information

Track Occupancy Authority

Track Occupancy Authority Applicability NSW SMS Publication Requirement External Only Document Status Issue/Revision # Effective from 4.0 11 October 2015 Australian Rail Track Corporation Limited (ARTC) Disclaimer This document

More information

Smoke Control BACnet PTEC Unit Vent Controller. Control Applications. Product Description. Product Numbers

Smoke Control BACnet PTEC Unit Vent Controller. Control Applications. Product Description. Product Numbers Document No. 550-161 Smoke Control BACnet PTEC Unit Vent Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 6675 through 6679 Product Description

More information

Public Address System Norwalk Public Schools REQUEST FOR PROPOSAL 1/16/15 Proposal Response Date:

Public Address System Norwalk Public Schools REQUEST FOR PROPOSAL 1/16/15 Proposal Response Date: Public Address System Norwalk Public Schools REQUEST FOR PROPOSAL 1/16/15 Proposal Response Date: NORWALK PUBLIC SCHOOLS Central Office 125 East Avenue Norwalk, Connecticut 06852-6001 Replacement of Public

More information

Level 2 Award in Employment Responsibilities and Rights in Health, Social Care and Children and Young People's Settings ( )

Level 2 Award in Employment Responsibilities and Rights in Health, Social Care and Children and Young People's Settings ( ) Level 2 Award in Employment Responsibilities and Rights in Health, Social Care and Children and Young People's Settings (4233-20) www.cityandguilds.com August 2017 Version 2.1 Qualification handbook for

More information

Level 2 Award/Certificate/Diploma in Cleaning and Support Services Skills ( )

Level 2 Award/Certificate/Diploma in Cleaning and Support Services Skills ( ) Level 2 Award/Certificate/Diploma in Cleaning and Support Services Skills (7648-02) Candidate Logbook www.cityandguilds.com July 2012 Version 2.0 Award 500/8105/6 Certificate 500/8104/4 Diploma 500/8182/2

More information