INTERNAL FRENCHFOLD DOOR SYSTEM

Similar documents
INTERNAL FRENCHFOLD DOOR SYSTEM

DIAMOND-TUFTED EXTENDED HEADBOARD BED COLLECTION

Thank you for purchasing the Actuator Systems NextBolt fingerprint deadbolt.

66CF1005 Certificate lifting equipment with new delivery Pag. 64/03

FlexoStretch. Product Description. Instruction Guide

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

INTRODUCTION. AUTHORIzATION A Word of Caution

Bedside cabinets and overbed tables

Caution! triangles are used to warn of situations that demand extra care and attention.

User-Service Manual Joerns Assist Handle Model F025

Improving Safety of Demil Operations Through Automation. Mark M. Zaugg July 14, 2010

KANOPY INTRODUCTION PRODUCT SPECIFICATION

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

1.5 to 5 Tons INDOOR COILS C33. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Overview. Airespace AP a Radio Card Quick Installation

Buck & Boost Transformer Installation Instructions

EasyCare Maximizing Care, Comfort and Safety

RP 5.0: INSPECTION AND CERTIFICATION OF MANUAL ROTARY TONGS

Manual Provided by emilitary Manuals -

TWISTER BINS FOR FLEXIBLE AND RELIABLE GRAIN STORAGE

Simply Practical. The Hill-Rom CareAssist ES Hospital Bed

ELECTRICAL INSPECTION ACT CANADIAN ELECTRICAL CODE REGULATIONS

MMO

SERVICE LETTER HC-SL Spinner - Bulkhead Modification

PRESSURE TACK WELDER CERTIFICATE OF COMPETENCY EXAMINATION

RP 12.0: INSPECTION OF CATWALKS. A Recommended Practice (RP) for the Canadian Land-Based Drilling

COMPANY PROFILE. Company Profile YOUR STRATEGIC PARTNER IN PRECISION ENGINEERING

INSIGNIA OF APPROVAL INFORMATION BOOKLET

USAF TECHNICAL TRAINING NAS Pensacola Florida Develop America's Airmen Today --- for Tomorrow

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

LF1090 BARIATRIc. USeR MANUAL. LF1090-INS-LAB-RevD GF Health Products, Inc.

Bariatric Bed Shown with options

Eleganza 3XC. Designed for ICU

Simply Intuitive. The Hill-Rom Advanta 2 Bed

CONVENIENCE METAL FABRICATION ABRASIVES VENDING SOLUTIONS CORNER STORE RIGHT ON THE FLOOR

CONVENIENCE CORNER STORE RIGHT ON THE FLOOR

TECHNICAL BULLETIN REPAIR OF DISPLAY/KEYPAD ASSEMBLY (A ) WITH REPAIR KIT A (NSN ) (EIC: N/A)

13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

School Safety Audit Checklist

ConCerto Shower trolley

Typical Cattlegrid Scenario

RP 1.0A: INSPECTION AND CERTIFICATION OF SUBSTRUCTURES. A Recommended Practice (RP) for the Canadian Land-Based Drilling and Well Servicing Industry

Handling the Bariatric Patient: Ergonomic Issues HoverTech International All Rights Reserved

EVENTS AND EXHIBITIONS EXHIBITIONS GUIDE

LF1090 BARIATRIC PATIENT LIFT

Instructions for Use and Disposal

Easylink to Square D Module

R E C L I N E R S E A T I N G

City of Waterbury Safety & Security Assessment

SECURITY FACTS!! Fire Protection. Force Protection Equipment Demonstration. In This Issue...

Veterans Federal Survivors Benefits and Allowances

Image 3. exclusive design to meet all your needs

CLASS TITLE: Bus driver/custodian/gardner Range 13

COMMERCIAL ITEM DESCRIPTION SHUNT, INSTRUMENT (EXTERNAL, 50 MILLIVOLT, 10 THROUGH 150 AMPERES (A) LIGHTWEIGHT TYPE)

Department of Veterans Affairs VHA HANDBOOK HOME IMPROVEMENTS AND STRUCTURAL ALTERATIONS (HISA) PROGRAM

RETAIL PRICELIST. Effective from May Unit 3, 10 Achievement Way Wangara WA 6065 Ph: Fax:

UNCLASSIFIED. AUD-MERO Office of Audits March 2017

Parts List. Commercial Series Refrigerated Kitchen Equipment

TARGUS NOTEBOOK SECURITY DEFCON SCL SERIALIZED COMBINATION CABLE LOCK

3.03 Functions of support services personnel Name

Presentation to support the: Immediate actions following an adult in-patient fall flow-chart: familiarisation with flat-lifting and use of Hoverjack

PRICE LIST MARCH 2016

Distribution Statement A: Approved for public release; distribution is unlimited.

Giving Intravenous (IV) Nutrition Through a Central Line with a CADD Pump

IHDA 47 ILLINOIS ADMINISTRATIVE CODE 368 TITLE 47: HOUSING AND COMMUNITY DEVELOPMENT CHAPTER II: ILLINOIS HOUSING DEVELOPMENT AUTHORITY

CARRIER, PERSONNEL, FULL TRACKED, ARMORED, M113A CARRIER, COMMAND POST, LIGHT TRACKED, M577A

GBH 24 VFR GBH 24 VRE

HEALTH AND SAFETY POLICY STATEMENT AND ARRANGMENTS MANUAL

Medical Grade Power Strips

SKS, $100. 1" /22, TAPCO

Rulemaking Hearing Rules of Department of Commerce and Insurance Division of Fire Prevention. Chapter Electrical Installations.

Rules on event organisation and entry

Creating a Healthcare Facility that Supports the Patient-Centered Medical Home

table of contents The American Cherry collection is inspired by original pieces of American built antiques. Fine Furniture Design

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

Redefining Patient Handling. prevention

HELICOPTER MECHANIC, HELICOPTER MECHANIC SUPERVISOR, 3749

TECHNICAL MANUAL OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

3.5 Emergency Procedures Policy (Evacuation & Invacuation)

A. General provisions and other electrical systems are specified in other Sections of Division 26.

SELECTIVE ADMISSIONS GUIDELINES SPRING 2018 DEADLINE: APRIL 13

Request for Proposal. Purchase of New Mobile Trailer Climbing Wall. No November 23, 2015

250- PERSONAL PROTECTIVE EQUIPMENT PROGRAM

TABLE OF CONTENTS FINAL ASSEMBLY (3 WIRE)... 1 FINAL ASSEMBLY (2 WIRE)... 2 DOOR ASSEMBLY (3 WIRE)... 4 DOOR ASSEMBLY (2 WIRE)...

Field Raked Poles. Southern Pine & Coastal Douglas-fir 32ft - 107ft Longer Poles Available Upon Request

TEST PROJECT / PROJET D ÉPREUVE CAR PAINTING PEINTURE AUTOMOBILE POST-SECONDARY / NIVEAU POSTSECONDAIRE

Read thoroughly before getting started. Patient User Guide

Maintenance Department Trades Person / Caretaker Full-time ongoing position 5 weeks annual leave. Role Description

Raiser s Edge: How To Query Constituent Giving With A Cumulative Total Including Soft Credits

Redefining Patient Handling. prevention

Pressure IQ Evolve Mattress Replacement System USER MANUAL

What will be covered in this NAEP workshop?

MITRE H A L C O N MT.

Request for Proposal P Computer Training Room Furniture

STATE OF MARYLAND MARYLAND JUDICIARY ADMINISTRATIVE OFFICE OF THE COURTS (AOC) REQUEST FOR PROPOSALS (RFP) # 2690

Right to Refuse The City of Coralville reserves the right to reject any and all quotes.

Product Brochure. If you would like to browse our website please click here

Instruction for use and trouble shooting guide

BANGKOK GEMS & JEWELRY FAIR 2018 September 7-11, 2018

CARMINA BARIAtRIC shower CoMMode ChAIR

Transcription:

INTERNAL FRENCHFOLD DOOR SYSTEM 3 AND 4 Patterns to Head clearance 3mm to Frame clearance 5-8mm Slave Daily Access /Master to floor clearance 17mm max IMPORTANT Please note: You can only assemble these door configurations by using the frame provided. Your warranty will be invalid if other alternatives are used. All loads are taken by the top track to ensure smooth, light operation and long life. Prior to installing this doorset, inspect for damage and do not proceed to fit if any noticeable damage or defect is evident. This doorset should be stored in a dry flat location before installation. CAUTION SAFETY: This product needs to be installed by a competent tradesperson with assistance. Two people are required to carry out the installation, as some components are heavy. The outer frame requires fixing to the supporting structure above the opening. The opening MUST be capable of carrying the load of the doorset in all conditions. Thank-you for purchasing your interior French-fold door system. This set up comes complete with Frame, s and all Ironmongery (except handle and latch) and is supplied in both 3 and 4 door systems to allow you to open up your rooms when required while still maintaining that interior French door look. Offering the benefit of folding completely back against the wall this revolutionary French-fold system gives you the benefit of bi-fold doors whilst retaining a central access point between rooms Frenchfold Internal Frenchfold Range PAGE 1 3 & 3 4 and 4 Systems System REV:01 Climadoor Interior Frenchfold System method of build 2018 v5.indd 1 30/04/2018 10:16

3 & 4 Systems 01 INSTALLING YOUR DOORS PACK COMPONENTS FRAME JAMBS FRAME HEAD STOP BEADS T-PIECE 818 PIVOT 360 DROP BOLT 282SS HINGE tbc 30mmx108mmx2001mm 2No 108mmX30mm 1No 3 door = 2384 long 4 door = 2836 long 2No 15x15x675mm (head stops) 2No 15x15x2001mm (jamb stops) 1981mm long 1No 3 door = 3 4 door = 6 3 door = 4 4 door = 4 3 door = 3 4 door = 4 02 FRAME SIZE AND DOOR OPTIONS Check you have correct frame for the door pattern you have ordered. Frame pack size supplied. No s / frame size ordered Pattern / Size ordered Std Frame Pack Supplied (WxH)mm Structural Opening size recommended (WxH)mm 3 1687 x 2031 2 + 1 x 533mm (21 ) 2384 x 2031 1697 x 2036 3 1807 x 2031 2 + 1 x 573mm (22.5 ) 2384 x 2031 1817 x 2036 3 1918 x 2031 2 + 1 x 610mm (24 ) 2384 x 2031 1928 x 2036 3 2146 x 2031 2 + 1 x 686mm (27 ) 2384 x 2031 2156 x 2036 4 2222 x 2031 2 + 2 x 533mm (21 ) 2384 x 2031 2232 x 2036 4 2381 x 2031 2 + 2 x 573mm (22.5 ) 2384 x 2031 2391 x 2036 4 2530 x 2031 2 + 2 x 610mm (24 ) 2836 x 2031 2540 x 2036 4 2834 x 2031 2 + 2 x 686mm (27 ) 2836 x 2031 2844 x 2036 The recommended structural opening sizes give a clearance of 10mm on the width & 5mm on the height to allow the frame to be installed square in the opening. Suggestion - Highlight the table to ensure you are working with the correct option before starting work. 3 & 4 Systems PAGE 2 Climadoor Interior Frenchfold System method of build 2018 v5.indd 2 30/04/2018 10:16

3 & 4 Systems 03 CUTTING YOUR HEAD DOWN The sizing required for your product and opening. No s / frame size ordered Pattern / Size ordered Std Frame Pack Supplied (WxH)mm Cut the head down to: 3 1692 x 2031 2 + 1 x 533mm (21 ) 2384 x 2031 1692 3 1810 x 2031 2 + 1 x 573mm (22.5 ) 2384 x 2031 1810 3 1924 x 2031 2 + 1 x 610mm (24 ) 2384 x 2031 1924 3 2152 x 2031 2 + 1 x 686mm (27 ) 2384 x 2031 2152 4 2226 x 2031 2 + 2 x 533mm (21 ) 2384 x 2031 2226 4 2384 x 2031 2 + 2 x 573mm (22.5 ) 2384 x 2031 No Cutting Required 4 2534 x 2031 2 + 2 x 610mm (24 ) 2836 x 2031 2534 4 2836 x 2031 2 + 2 x 686mm (27 ) 2836 x 2031 No Cutting Required Suggestion - Highlight the table to ensure you are working with the correct option before starting work. 04 ASSEMBLING YOUR FRAME Using a 3mm drill bit, drill two holes through the head into the top of the jambs approx 75mm deep. Countersink as necessary. 108 Fix the jambs using 2no 75mm screws both ends. 153mm 1830mm Position the 818 pivots as shown with the leading edge in line with the front edge of the frame. Carefully Counterbore into the frame using a router for the pivot housings. Ø11.5 40.0 6.5 3 & 4 Systems PAGE 3 Climadoor Interior Frenchfold System method of build 2018 v5.indd 3 30/04/2018 10:16

3 & 4 Systems 05 INSTALL YOUR FRAME IN THE OPENING Using appropriate fixings, attach the frame in the opening with the front of the jamb face either in line, or slightly in front of the facing wall (2-3mm). All fixings at 450mm centres NOTE Check corner to corner measurements after fixing to ensure frame is square & plumb in opening. Diagonal measure + or - 5mm maximum tolerance Bottom fixings at 600mm centres Facing wall of opening Head 2-3mm in front of face wall Jamb 3 & 4 Systems PAGE 4 Climadoor Interior Frenchfold System method of build 2018 v5.indd 4 30/04/2018 10:16

3 & 4 Systems 06 CHECK YOUR INTERNAL REBATE MEASUREMENT Before proceeding, check the internal frame rebate dimensions to ensure they are correct & adjust frame as necessary. No s / frame size ordered Pattern / Size ordered Internal Rebate Size Req: 3 1692 x 2031 2 + 1 x 533mm (21 ) 1632 3 1810 x 2031 2 + 1 x 573mm (22.5 ) 1750 3 1924 x 2031 2 + 1 x 610mm (24 ) 1864 3 2152 x 2031 2 + 1 x 686mm (27 ) 2092 4 2226 x 2031 2 + 2 x 533mm (21 ) 2166 4 2384 x 2031 2 + 2 x 573mm (22.5 ) 2324 4 2534 x 2031 2 + 2 x 610mm (24 ) 2474 4 2836 x 2031 2 + 2 x 686mm (27 ) 2776 07 INSTALLING YOUR DOORS A: Fit the pivot hinges into pre-machined holes in the frame jambs with each pivot pin facing each other (reversing the hinge flag as necessary by unscrewing the bolt through the hinge). 153mm 25.0 7.0 11.0 12.5 10.0 10.0 6.5 40.0 13.0 Ø12.5 B: Screw in the main body of the bolt into the mounting plate until the back of the hinge flag is approx 1mm from jamb face for optimum adjustment. 3 & 4 Systems PAGE 5 Climadoor Interior Frenchfold System method of build 2018 v5.indd 5 30/04/2018 10:16

3 & 4 Systems 08 FRENCH FOLD - 3 DOOR Fit drop bolts and door overview of door operation. 3 No 282SS Hinges Plan View to Head clearance 3mm to Frame clearance 5-8mm / Slave Daily Access to floor clearance 17mm max 3 & 4 Systems PAGE 6 Climadoor Interior Frenchfold System method of build 2018 v5.indd 6 30/04/2018 10:16

3 & 4 Systems 09 FRENCH FOLD - 4 DOOR Fit drop bolts and door overview of door operation. 3 No 282SS Hinges Plan View to Head clearance 3mm to Frame clearance 5-8mm Slave Daily Access /Master to floor clearance 17mm max 3 & 4 Systems PAGE 7 Climadoor Interior Frenchfold System method of build 2018 v5.indd 7 30/04/2018 10:16

3 & 4 Systems 10 FLUSH BOLT MACHINING Install flush bolt to panel 9[0.35] 110 24[0.95] 24mm Router required 11 ATTACHING THE DOORS A. Attach each pivot door to the pivot hinges leaving a 3mm gap at the top of the door between the door & frame-head. B. Using 3 No face fix 282SS hinges attach the daily access door (& slave door) to the pivot doors being careful to place them on the correct edge of the doors (refer door overview arrangements) C. Fit the T piece section to the meeting stile of the slave door to act as a door stop for the master door. D. Adjust the doors as necessary to ensure they are square and operate properly. E. Trim the door stop beads to the width of the pivot door and attach to the frame head to stop the pivot door closing past 180. Head Jamb / Slave Stop Beads Jamb Reverse side of doorset F. Once the door stops are fitted, close the doors and mark out positions of the drop bolt keeps on the head, face fix using screws provided (dust box not required). Repeat on any flush bolts for the bottom of the doors. 3 & 4 Systems PAGE 8 Climadoor Interior Frenchfold System method of build 2018 v5.indd 8 30/04/2018 10:16

3 & 4 Systems NOTES: 3 & 4 Systems PAGE 9 Climadoor Interior Frenchfold System method of build 2018 v5.indd 9 30/04/2018 10:16

3 & 4 Systems NOTES: 3 & 4 Systems PAGE 10 Climadoor Interior Frenchfold System method of build 2018 v5.indd 10 30/04/2018 10:16

3 & 4 Systems NOTES: 3 & 4 Systems PAGE 11 Climadoor Interior Frenchfold System method of build 2018 v5.indd 11 30/04/2018 10:16

3 & 4 Systems Climadoor Interior Frenchfold System method of build 2018 v5.indd 12 30/04/2018 10:16