COMPRESSOR TECHNICAL OVERVIEW

Similar documents
Specifications, Performance & Submittal

REQUEST FOR PROPOSALS

1.5 to 5 Tons INDOOR COILS C33. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

B. All of the documents in this RFP form the Basis-of-Design for this project.

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

AIR CONDITIONER HORIZONTAL, COMPACT, 9,000 BTU/HR, 115 VOLT SINGLE PHASE 50/60 HERTZ PART NO. S8450-9KC-1H (NSN ) (EIC: N/A)

WEST BENGAL ELECTRONICS INDUSTRY DEVELOPMENT CORPORATION LIMITED (WEBEL ) TENDER DOCUMENTS

Spare Part Catalogue. Star Cool refrigeration unit Model SC MCI40, SCU and SCI

Energy Optimization Plan

Setting a new standard for performance, safety and simplicity

smart technologies Neonatal incubator from standard to intensive care

/ I N S T I T U T E t r a i n i n g c a t a l o g f a l l 2015

Product Introduction. Specification Sheet. Certificates. Application. Features. Street Light

CHAPTER 35 FIREMAN (FN) NAVPERS A CH-52

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

Approved for public release. Distribution is unlimited.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

Isolette 8000 Neonatal Closed Care

Declaration of Classification ValiSpore Incubator Manual

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

12/4/2017 ICE BOOK 1 WELBILT KITCHENCARE PARTS PRICE BOOK LIST PRICE USD BRAND PART NUMBER DESCRIPTION UOM SUBSTITUTE PART NUMBER

/ I N S T I T U T E t r a i n i n g c a t a l o g s p r i n g 2018

Isolette TI500 Neonatal Transport

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

Eleganza 3XC. Designed for ICU

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa HEALTH & SAFETY POLICY EMERGENCY MANAGEMENT POLICY

AMC 30% 40% 10% 20% Electric power(kw) kw 25,44. Rotation speed (rpm) rpm 40,00. Got the Cochlea to reach the maximum availability of water

Green tax incentives and credits for businesses and individuals. Federal and state planning ideas

PO #GS-02F-0070S

Advt. No. AIIMS/RIS/DR-Gr C /2014/ Dated:

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

Lodestar. Series. Specification Sheet. Application. Features. Floodlight. Tunnel Lighting. Parking Applications. Canopy Lighting Wash Lighting.

*TB HEADQUARTERS, DEPARTMENT OF THE ARMY WASHINGTON, DC, 1 AUGUST 1999

6-3 [D5A0] WIRING DIAGRAM. 5. Wiring Diagram. 5. Wiring Diagram A: POWER SUPPLY ROUTING

What will be covered in this NAEP workshop?

smart technologies Neonatal incubator from standard to intensive care

PPL s Business Energy Efficiency Program Direct Discount for Small Commercial & Industrial

Recommended Physical Plant Improvements to Existing Nursing Homes for Disaster Preparedness. Report to the Governor and to the Legislature

Tender Information. Ethiopia (EEPC Ref. No. DB-1088) Rwanda (EEPC Ref. No. DB-1089) Overseas Information. Project ID No. : P Credit from IDA

Subj: FULL POWER AND ECONOMY TRIAL REQUIREMENTS FOR NON-NUCLEAR SURFACE SHIP CLASSES

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

Pedernales Electric Cooperative. Residential HVAC Rebate Program Manual

Rebates & Incentives - WTF. Lee Guthman February 28, 2012

... Top Quality Assurance Bizerba CWE Checkweigher

ANNUAL SURVEY PREPARATION. For Year-Long Compliance May 21, 2014 Adam Snyder, RVP, Unidine Jenny Overly, Director of Innovation, Unidine

Image 3. exclusive design to meet all your needs

Licence Application Decision

Medical Baseline Allowance Program

Introduction. Welcome to Human Care.

Humidity in Anesthetizing Locations Where Mechanical Systems and Compliance Collide

Q COLORADO DSM ROUNDTABLE. May 6, 2015

66CF1005 Certificate lifting equipment with new delivery Pag. 64/03

DEPARTMENT OF THE ARMY TECHNICAL MANUAL *TM DEPARTMENT OF THE AIR FORCE TECHNICAL ORDER TECHNICAL MANUAL

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

Sub : Guidelines for Procurement from Micro and Small Enterprises (MSEs)

Parts List. Commercial Series Refrigerated Kitchen Equipment

Student Organization Housing. Project Initiation Request (PIR)

2014 PROGRAM MANUAL. Large Commercial MTP. El Paso Electric

SEA TERM 2016 Engineering Watchstanding Manual. Massachusetts Maritime Academy Buzzards Bay, Massachusetts

Power NI Variable Speed Drive Grant 2015/16

VERTICAL TURBINE. PUMPS Repair Parts Table

Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY. 1 WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM August 2010 eere.energy.

Medical furniture OPTIMA OBSTETRIC BED

Medical Grade Power Strips

RETAIL READY HVAC MAINTENANCE READY TECH. Career Center. 6 Week Training Program. Empowering Students. Evolving Education.

Classified Employee Food Services Manager Serving Kitchen (Elementary) JOB DESCRIPTION

Isolette 8000 plus Neonatal Closed Care

Residential Heating and Cooling Program

Water Heating Program Guide

5US1-2 EDITION. Parts & Accessories 2 EDITION

Con Edison Commercial and Industrial Energy Efficiency Program

Ground Source Heat Pump - July 1, 2016 through June 30, 2017

Department of the Air Force. Military Family Housing. Fiscal Year (FY) 2013 Budget Estimate

Agricultural Energy Program Grant

AQUATIC HEALTH PROGRAM PLAN REVIEW SUBMISSION INSTRUCTIONS FOR MINOR REMODEL

AIR CONDITIONING AND REFRIGERATION Administrative Rules of the Texas Department of Licensing and Regulation 16 Texas Administrative Code, Chapter 75

Providing Quality Equipment and Services for Specialized Mechanical Air Systems. Serving Kentucky and Southern Indiana for over 70 years

Approved for public release. Distribution is unlimited.

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE 2A & 2B Raja S.C.Mullick Road Jadavpur, Kolkata

Affinity Four Birthing bed Delivering Safety

FORM CMS (2/2013)

MULTIFAMILY UPGRADE CUSTOMER HANDBOOK

Manitoba Geothermal Energy Incentive Program

COMMERCIAL ITEM DESCRIPTION SHUNT, INSTRUMENT (EXTERNAL, 50 MILLIVOLT, 10 THROUGH 150 AMPERES (A) LIGHTWEIGHT TYPE)

May 6, 2002 Revision 2

NURSE CALLING SYSTEM

ConCerto Shower trolley

Magnetic contactor, Thermal overload relay, auxiliaries. LSISC0., Ltd. 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do Korea, Republic of

INNOVATIVE OPPORTUNITIES FOR FINANCING ENERGY EFFICIENCY UPGRADES

More comfortable childbirth

F200DET 13 (6CD5) F225DET 13 (6CC5) F250CET 13 (6CB5)

ARMY RDT&E BUDGET ITEM JUSTIFICATION (R2 Exhibit)

University Facilities Personal Protective Equipment Procedure

Distribution Statement A: Approved for public release; distribution is unlimited.

2011 Landfill Operator s Conference. R. W. Beck, An SAIC Company 1

England Energy Efficiency Loans Application Notes

For more information, call or

Public Art RFQ. California Air Resources Board. Request for Qualifications Public Art. California Air Resources Board

SAMPLE. Child Care Center Sanitation Inspection Form

BOILER WATER TREATMENT Standard Boiler Water Treatments

Transcription:

AWECO COMPRESSOR TECHNICAL OVERVIEW COMMERCIAL REFRIGERATION HEAT PUMP sanhuaclimate.com 1

AWECO Key compressor range - typical applications Page AWECO Series Refrigerant Control Typical Application 2 QXER R134a On/Off Heat pump - Sanitary water tank 6 QXDR R290 On/Off Heat pump - Sanitary water tank 8 QXD R290 On/Off Refrigeration + Air conditioning 10 ATz R410A Inverter Heat pump - Ground water QXER Compressor Series GENERAL SPECIFICATION Application: Heat Pump - Sanitary Water / Dehumidifier / Refrigeration medium temperature Net supply: 2V/1Ph/Hz Refrigerant: R134a Control: On/Off PERFORMANCE DATA - R134A 1) Displacement [cm 3 ] Cooling Power Input 2) Heating COP Heating 2) Sound Power 2) [db(a)] Max. Ref. Charge [g] QXER-B109 E1 10,9 12 4 1690 3,84 67 10 QXER-B122 C1 12,2 14 4 1890 4,11 67 10 QXER-B15 C0 15,0 17 6 23 3,76 65 1000 QXER-C18 E0 18,0 2100 0 2800 4,00 68 10 QXER-D253 F0 25,3 29 9 3880 4,04 71 10 QXER-F36 F0 35,6 43 1480 58 3,95 71 Note: 1) Extent of delivery: Compressor, terminal cover, nut and gasket for terminal cover and 3 pcs. grommet 2) Conditions ASHRAE: Conditions ASHRAE: Evap. temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C Exception: QXER-B15 C0: Evap. temp. +10 C; cond. temp. C; liquid temp. C; suction gas temp. C ELECTRICAL DATA Locked Rot. Current LRA Absorbed Current 1) Run Capacitor [μf/v] QXER-B109 E1 19,3 2,0 25/4 QXER-B122 C1 14,0 2,1 25/4 QXER-B15 C0,0 3,0 25/4 QXER-C18 E0 22,0 3,3 /4 QXER-D253 F0,0 4,7 35/4 QXER-F36 F0 43,5 6,8 55/4 Note: 1) Conditions ASHRAE: Evap. temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C Exception: QXER-B15 C0: Evap. temp. +10 C; cond. temp. C; liquid temp. C; suction gas temp. C 2 sanhuaclimate.com

DIMENSIONS Total Height H Comp. ød 1 Bolt circle installation plate ød 2 Suction Discharge QXER-B109 E1 286 118 1 12,2 9,7 11,4 QXER-B122 C1 285 118 1 12,2 9,7 12,0 QXER-B15 C0 312 118 175 12,2 9,7 12,0 QXER-C18 E0 3 128 175 12,2 9,7 15,0 QXER-D253 F0 325 132 175 12,2 9,7 16,5 QXER-F36 F0 367 146 175 16,2 9,7 21,4 Weight [kg] Drawing: QXER-B109E1 ød 2 H ød 1 SANHUA is the world s largest producer of Micro-Channel Heat Exchangers for Stationary HVAC&R application SANHUA DELIVERS OVER 1,0,000 MCHE CONDENSERS (CO & HP) AND EVAPORATORS HELPING TO IMPROVE SYSTEM EFFICIENCY BY UP TO %

OPERATING ENVELOPES - R134A QXER-B109E1 QXER-B122C1 80 85 75 65 55 45 35 25 10 15 - - -10 0 10 5 - - -10 0 10 QXER-B15C0 QXER-C18E0 80 90 80 10 - -10 0 10 QXER-D253F0 and QXER-F36F0 - -10 0 10 = Area of emergency operation: Max. min. 80 - -10 0 10 4 sanhuaclimate.com

YOUR ROAD MAP TO THE ECO-DESIGN DIRECTIVE* KEEPS YOU ONE STEP AHEAD OF THE COMING EFFICIENCY AND ENVIRONMENTAL EUROPEAN CHALLENGES ADERAL.ES ADVANCED Technology & Solutions ideas worldwide SANHUA INTERNATIONAL info@sanhuaeurope.com

QXDR Compressor Series GENERAL SPECIFICATION Application: Heat Pump - Sanitary Water Net supply: 2V/1Ph/Hz Refrigerant: R290 Control: On/Off PERFORMANCE DATA - R290 1) Displacement [cm 3 ] Cooling Power Input 2) Heating COP Heating 2) Sound Power 2) [db(a)] Max. Ref. Charge [g] QXDR-A058 L1 5,8 8 2 1080 4,15 64 3 QXDR-A088 T1 8,8 13 425 1745 4,11 64 3 QXDR-B222 A0 22,2 33 10 4380 4,29 67 800 QXDR-D5 F0,8 47 10 61 4,39 71 800 Note: 1) Extent of delivery: Compressor, terminal cover, nut and gasket for terminal cover and 3 pcs. grommet 2) Conditions ASHREA: Evap. temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C ELECTRICAL DATA Locked Rot. Current LRA Absorbed Current 1) Run Capacitor [μf/v] QXDR-A058 L1 6,0 1,2 15/4 QXDR-A088 T1 13,0 1,9 /4 QXDR-B222 A0 26,5 4,6 35/4 QXDR-D5 F0 33,0 6,1 45/4 Note: 1) Conditions ASHREA: Evap. temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C 6 sanhuaclimate.com

DIMENSIONS Total Height H Comp. ød 1 Bolt circle installation plate ød 2 Suction Discharge QXDR-A058 L1 254 107 1 9,7 6,2 7,9 QXDR-A088 T1 2 107 1 9,7 6,2 9,0 QXDR-B222 A0 8 118 175 12,2 9,7 13,0 QXDR-D5 F0 3 132 175 16,2 9,7,0 Weight [kg] Drawing: QXDR-A088T1 ød 2 H ød 1 OPERATING ENVELOPES - R290 QXDR-A058L1... QXDR-B222A0 80 - -10 0 10 Operating envelope QXDR-D5F0 available on request. sanhuaclimate.com 7

QXD Compressor Series GENERAL SPECIFICATION Application: Refrigeration Medium Temp / Dehumidifier / Air conditioning Net supply: 2V/1Ph/Hz Refrigerant: R290 Control: On/Off PERFORMANCE DATA - R290 1) Displacement [cm 3 ] Cooling Power Input 2) Heating COP Cooling 2) Sound Power 2) [db(a)] Max. Ref. Charge [g] QXD-G058 P2 5,8 785 3 1105 2,45 52 0 QXD-A066 W1 6,6 980 3 1310 2,97 on request 3 QXD-A081 L1 8,1 12 375 1595 3,25 64 0 QXD-A121 L1A 12,1 1780 610 2390 2,92 64 3 QXD-C173 A0 17,3 25 795 3345 3,21 67 800 QXD-C184 A0A 18,4 2710 8 35 3, 67 800 QXD-C218 A0A 21,8 30 9 41 3, 67 800 QXD-B222 A0 22,2 1010 4410 3,37 on request on request QXD-E34 F0 34,0 50 10 60 3,47 71 800 Note: 1) Extent of delivery: Compressor, terminal cover, nut and gasket for terminal cover and 3 pcs. grommet 2) Conditions ASHREA: Evap. temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C ELECTRICAL DATA Locked Rot. Current LRA Absorbed Current 1) Run Capacitor [μf/v] QXD-G058 P2 7,0 1,6 6,5/4 QXD-A066 W1 10 1,5 15/4 QXD-A081 L1 7,0 1,7 15/4 QXD-A121 L1A 13 2,9 /4 QXD-C173 A0 22 3,6 25/4 QXD-C184 A0A 22 3,8 25/4 QXD-B222 A0 26 4,8 /4 QXD-E34 F0 6,8 /4 Note: 1) Conditions ASHREA: Evap temp. 7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C" 8 sanhuaclimate.com

DIMENSIONS Total Height H Comp. ød 1 Bolt circle installation plate ød 2 Suction Discharge QXD-G058 P2 225 92 1 8,2 6,2 5,0 QXD-A066 W1 2 107 1 9,7 6,2 8,0 QXD-A081 L1 254 107 1 9,7 6,2 8,4 QXD-A121 L1A 259 107 1 9,7 6,2 8,0 QXD-C173 A0 314 128 175 12,2 9,7 13,8 QXD-C184 A0A 314 128 175 12,2 9,7 13,8 QXD-C218 A0A 314 128 175 12,2 9,7 14,9 QXD-B222 A0 8 118 175 12,2 9,7 13,2 QXD-E34 F0 357 141 176 16,2 9,7,2 Weight [kg] Drawing: QXD-C184A0A ød 2 H ød 1 OPERATING ENVELOPES - R290 Evap. temp. range [ C] Cond. temp. range [ C] Overload protector action temp. [ C] Application QXD-G058P2 QXD-G058 P2-10 +15 27 115 Dehumidifier QXD-A066 W1 0 +35 75 on req. Air Conditioner QXD-A081 L1-10 +15 27 on req. Air Conditioner QXD-A121 L1A -15 +15 27 67 125 Air Conditioner QXD-C173 A0-15 + 35 65 115 Refrigeration MT QXD-C184 A0A -15 + 35 65 115 Refrigeration MT QXD-C218 A0A -15 +15 27 68 125 Air Conditioner QXD-B222 A0-15 +15 27 68 on req. Air Conditioner QXD-E34 F0-15... + 35... 65 on req. Air Conditioner QXD-C173A and QXD-C184A0A - -10 0 10 - -10 0 10 sanhuaclimate.com 9

ATz Compressor Series GENERAL SPECIFICATION Application: Heat Pump Ground Water, Air Conditioning Net supply: 1-Phase and 3-phase net supply Refrigerant: R410A Control: Inverter 900 70rpm (15 1Hz) PERFORMANCE DATA R410A 1) Displacement [cm 3 ] Absorbed Current 1) Cooling Power supply Power Input 2) Heating COP Heating 2) Motor Technology ATz-AA098AHBA 4,0 2V/1Ph/Hz Permanent Magnet Synchronous Motor ATz-SM151AXBA 4,6 2V/1Ph/Hz Permanent Magnet Synchronous Motor ATz-SD23AXAF 11,5 2V/1Ph/Hz Permanent Magnet Synchronous Motor ATz-SD32AXAF 15,1 2V/1Ph/Hz Permanent Magnet Synchronous Motor Sound Power 2) [db(a)] Max. Ref. Charge [g] ATz-AA098AHBA 9,8 35 8 4410 5,07 72 1000 ATz-SM151AXBA 15,1 5380 1295 6675 5,15 74 16 ATz-SD23AXAF 23,1 71 24 90 3,92 78 ATz-SD32AXAF 32,1 100 33 134 3,99 79 Note: 1) Extent of delivery: Compressor, terminal cover, nut and gasket for terminal cover and 3 pcs. grommet 2) Conditions: ATz-AA098 and ATz-SM151: Evap. temp. +10 C; cond. temp. 46 C; liquid temp. 41 C; suction gas temp. +18 C; rpm (Hz) Conditions ASHREA: ATz-SD23 and ATz-SD32: Evap. temp. +7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C; rpm (Hz) ELECTRICAL DATA Note: 1) Conditions: ATz-AA098 and ATz-SM151: Evap. temp. +10 C; cond. temp. 46 C; liquid temp. 41 C; suction gas temp. +18 C; rpm (Hz) Conditions ASHREA: ATz-SD23 and ATz-SD32: Evap. temp. +7,2 C; cond. temp. 54,4 C; liquid temp. 46,1 C; suction gas temp. 35 C; rpm (Hz) 1 Phase Supply: DIMENSIONS Total Height H Comp. ød 1 Bolt circle installation plate ød 2 Suction Discharge ATz-AA098AHBA 262 108 1 12,9 8,2 7,8 ATz-SM151AXBA 311 114 1 12,2 8,2 9,4 ATz-SD23AXAF 389 132 175 16,2 9,7 15,7 ATz-SD32AXAF 391 132 175 16,2 9,7 16,5 Weight [kg] Drawing: ATz-SD23AXAF H ød 1 ød 2 10 sanhuaclimate.com

OPERATING ENVELOPES - R410A ATZ-AA098AHBA, ATZ-SM151AXBA, ATZ-SD23AXAF, ATZ-SD32AXAF 15-29 Hz -44 Hz - - -10 0 10 - - -10 0 10 45-90 Hz 91-100 Hz - - -10 0 10 - - -10 0 10 101-1 Hz - - -10 0 10 = Area of no continous operation sanhuaclimate.com 11

sanhuaclimate.com SANHUA INTERNATIONAL info@sanhuaeurope.com DS-AWECO COMP-EN-R1802 ideas worldwide