New Fire Safety Rules Summary Evvie Munley, LeadingAge

Similar documents
Life Safety Code Update for Hospitals and Nursing Homes May 3, 2012

Minnesota Health Care Engineers Association. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

Department of Health Update

Adult Family Care Home Top Ten Health Deficiency Citations Statewide October 8, 2009 Year Date Range: January 1, 2008 through December 31, 2008

Prepublication Requirements

Facility Demographic Report

CMS Proposed Rule

Agency for Health Care Administration

How to Submit Waivers and Equivalencies

F Physical Environment The facility must be designed, constructed, equipped, and maintained to protect the health and safety of residents,

Medicare Conditions for Coverage 2009 Crosswalk

M E M O R A N D U M. NFPA Technical Committee on Health Care Occupancies. Diane Matthews, Project Administrator

Preparing for Life Safety Code Surveys with the Joint Commission - Part 2. Florida Hospital Association. Wednesday, May 2, 2018 WELCOME!

Medicare and Medicaid Programs; Emergency Preparedness Requirements for Medicare and Medicaid Participating Providers and Suppliers

Long Term Care Requirements CMS Emergency Preparedness Final Rule

Navigating the Codes in Henry Kosarzycki, A.I.A. Architect/State Fire Authority September 12, 2013

CMS Emergency Preparedness Rule

TOP 10 DEFICIENCIES, SECOND QUARTER FY 2015.xls

Standards. Successfully Preparing for Your Next AAAHC Accreditation Survey Annual Conference

APPENDIX I HOSPICE INPATIENT FACILITY (HIF)

Programs of All-Inclusive Care for the Elderly Requirements CMS Emergency Preparedness Final Rule

Recommended Physical Plant Improvements to Existing Nursing Homes for Disaster Preparedness. Report to the Governor and to the Legislature

CALIFORNIA STATE UNIVERSITY, OFFICE OF THE CHANCELLOR Telecommuting Policy and Guidelines For CSUEU Employees

SAMPLE: Environmental Rounds and Safety Assessment Tool

SUBCHAPTER 31. MANDATORY PHYSICAL ENVIRONMENT

No. 22 in In accordance to articles 152 & 108 / second of Labor Law no. (71) of 1987 we decided to issue the following instructions:

Health Care Construction Projects

Missouri. Phone. Agency (573)

Wisconsin. Phone. Agency Department of Health Services, Division of Quality Assurance, Bureau of Assisted Living (608)

District of Columbia. Phone. Agency. Department of Health, Health Regulation and Licensing Administration (202)

SENIOR/ASSISTED LIVING FACILITY SPECIFIC QUESTIONNAIRE

New York City Fire Department Instructions for Preparation and Submission of Emergency Action Plan (EAP) for Office Buildings

Standard EC Elements of Performance for EC The hospital manages fire risks.

Iowa. Phone. Web Site. Licensure Term

Medicare and Medicaid Program; Regulatory Provisions to Promote Program Efficiency, Transparency, and Burden Reduction. Summary of Proposed Rule

Arizona Department of Health Services Licensing and CMS Deficient Practices

The Pre-Construction Risk Assessment

Summary, January 8, 2013

Hospital (and Transplant Center) Requirements as Written in the Final Rule

Rule R Nursing Facility Construction. Table of Contents. State Links: Utah.gov State Online Services Agency List Business.utah.gov Search.

ARSD 67 :42:07 : :42:07 :01. Definitions.

The CMS Rule and Healthcare Coalitions

Post Acute Care. Kyle Devine, M.S.W. Bureau Chief

The Joint Commission and Facility Design: A Partnership for Patient Safety and Quality Care

Report to the General Assembly: Nursing Home Inspection and Enforcement Activities. A Report to the 105 th Tennessee General Assembly

Department of Health and Human Services, Division of Public and Behavioral Health, Bureau of Health Care Quality and Compliance

Center for Medicaid, CHIP, and Survey & Certification/Survey & Certification Group

EMERGENCY PREPAREDNESS REQUIREMENTS Long Term Care Facility Overview

Manhattan Fire Protection District

Prepublication Requirements

ND CAH Quality Pre-Conference

Organization and administration of services

Observations will be made of the storage. knowledge of the hazardous materials. labeling the container to the use of. containers (which may range from

Prepublication Requirements

HORRY COUNTY FIRE RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING GUIDELINE. SOG 607 Live Fire Training in Acquired Structures

Home Health Agency Requirements CMS Emergency Preparedness Final Rule

Using Body Mechanics

By now, everyone should be very familiar with the H&S Guidance contained in WPN For that reason, we won t review the entire WPN 17-7, but just

EXISTING CONDITIONS

Head Start Facilities and Safe Environments Checklist

The Healthcare Environment Challenges and Update

LEGALLY-EXEMPT CHILD CARE HEALTH AND SAFETY REQUIREMENTS

GRILLS MODEL MWG-9501 MODEL MWGH-9501 MODEL MWGF-9501 MODEL MWGL-9501 MODEL MWGR-9501 WIRING DIAGRAMS

ANNEX 2 RESOLUTION MSC.216(82) (adopted on 8 December 2006)

TRENDING IN THE JOINT COMMISSION

Laboratory Safety Coordinator Meeting. Fall 2011

Clinics, Rehabilitation Agencies, and Public Health Agency Requirements CMS Emergency Preparedness Final Rule

245D-HCBS Community Residential Setting (CRS) Licensing Checklist

Emergency Preparedness

EMERGENCY PREPAREDNESS ACUTE CARE

West Virginia. Phone. Agency (304)

SWING BED (SWB) Rural Hospitals under 100 Beds and Critical Access Hospitals

Mary Massey, BSN, MA, CHEP California Hospital Association

The Regulatory Focus. Critical Access Hospitals The Regulatory Process

2016 Final CMS Rules vs. Joint Commission Requirements

upgrade to consider may be the Heating Ventilation and Air Conditioning (HVAC) system. Facilities may have to maintain higher humidity & filtration le

HARBEX METAL PROCESSING LTD. Health and Safety Policy and Procedures

Alabama Medicaid Adult Day Health Minimum Standards

Basic Personal and Environmental Safety Precautions

Overview of the CMS Emergency Preparedness Final Rule

Notice of Proposed Rule

RULES OF TENNESSEE DEPARTMENT OF MENTAL HEALTH AND MENTAL RETARDATION CHAPTER ADEQUACY OF FACILITY ENVIRONMENT AND ANCILLARY SERVICES

Joint Commission: Insight into the Top Cited Elements of Performance and SAFER Scoring

San Francisco General Hospital ENVIRONMENT OF CARE (EOC)/SAFETY MANAGEMENT 2006 Annual Report

YORK COUNTY FIRE SCHOOL STRUCTURAL BURN BUILDING USAGE MANUAL

Niagara County Emergency Services

1 What is an AAAHC/Medicare Deemed Status survey? 2 What are the Medicare Conditions for Coverage (CfC)?

Date: September 2, Assisted Living Facilities (ALFs) To:

D ISASTER AND E MERGENCY P REPAREDNESS 101

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa HEALTH & SAFETY POLICY EMERGENCY MANAGEMENT POLICY

Specific Excerpts for Long Term Care Facilities (LTC) and Intermediate Care Facilities for Individuals with Intellectual Disabilities June 1, 2017

April 10, 2018 York Chan, CHFM, CHC, SASHE

Joint Commission Resources Quality & Safety Network (JCRQSN)

Joint Commission Resources Quality & Safety Network (JCRQSN) Resource Guide. Centers for Medicare & Medicaid Services (CMS): Emergency Preparedness

CHEMICAL HYGIENE PLAN

ARTICLE 6. PHYSICAL PLANT. s Alterations to Existing Buildings or New Construction.

Welcome ADFCA AD EHSMS Workshop

Formal Interpretations Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014 edition

Health and Safety at Work (General Risk and Workplace Management) Regulations 2016 (LI 2016/13)

Powering Our Communities. Grant Guidelines

Transcription:

New Fire Safety Rules Summary Evvie Munley, LeadingAge Following is the link to the Centers for Medicare and Medicaid Services (CMS) Final Rule, Medicare and Medicaid Programs; Fire Safety Requirements for Certain Health Care Facilities, published in the Federal Register today, May 4, 2016, and effective July 5, 2016. https://www.gpo.gov/fdsys/pkg/fr-2016-05-04/pdf/2016-10043.pdf This Rule amends the fire safety standards for Medicare and Medicaid participating hospitals, critical access hospitals (CAHs), long-term care facilities, intermediate care facilities for individuals with intellectual disabilities (ICF-IID), ambulatory surgery centers (ASCs), hospices providing inpatient services, religious non-medical health care institutions (RNHCIs), and programs of all-inclusive care for the elderly (PACE) facilities. The Rule adopts the 2012 edition of the Life Safety Code (LSC), which contains several changes from the 2000 LSC. It also adopts the 2012 edition of the Health Care Facilities Code, with some exceptions. Chapter 43 Building Rehabilitation The 2000 LSC requires minor renovation projects to meet the same requirements as those applied to completely new construction. The 2012 LSC Chapter 43--Building Rehabilitation'' replaces the requirements that all modernizations/renovations meet the requirements for new construction. The degree to which requirements for new construction must be met now varies with the rehabilitation work category. o Buildings that have not received all pre-construction governmental approvals required by their respective jurisdiction(s) before the rule's effective date, or those buildings that begin construction after the effective date, will be required to meet the New Occupancy chapters of the 2012 LSC. o Buildings constructed before the effective date of this regulation will be required to meet the Existing Occupancy chapters of the 2012 LSC. Changes made to buildings would be required to comply with Chapter 43--Building Rehabilitation, which could require compliance with the New Occupancy chapters, depending on the changes being made. The following provisions appear in the 2012 LSC, but did not exist in the 2000 LSC, for Chapter 18, New Health Care Occupancies,'' and Chapter 19, Existing Health Care Occupancies.'' 18.2.3.4 (2) and 19.2.3.4(2)--Corridor Projections: Requires noncontinuous projections to be no more than 6 from the corridor wall. However, in addition to the requirements of the LSC, health care facilities are also required to follow the Americans with Disabilities Act (ADA). Section 307 of the ADA Accessibility Guidelines for Buildings and Facilities (http://www.ada.gov/regs2010/2010adastandards/2010adastandards.htm#c4) requires

that objects mounted above 27 and no more than 80 high be no more than 4 from the corridor wall. CMS intends to provide technical assistance regarding strategies for avoiding noncompliance with the ADA. 18.7.5.7.2 and 19.7.5.7.2 Recycling: Requires that containers used solely for recycling clean waste be limited to a maximum capacity of 96 gallons. If the recycling containers are located in a protected hazardous area, container size will not be limited. 18.3.6.3.9.1 and 19.3.6.3.5--Roller Latches o CMS is not adopting the 2012 LSC provision permitting roller latches on corridor doors, i.e., Through fire investigations, roller latches have proven to be an unreliable door latching mechanism requiring extensive maintenance to operate properly. Many roller latches in fire situations failed to provide adequate protection to residents in their rooms during an emergency. o Roller latches will be prohibited in existing and new Health Care Occupancies for corridor doors and doors to rooms containing flammable or combustible materials. These doors will be required to have positive latching devices instead. 18.4.2 and 19.4.2--Sprinklers in High-Rise Buildings: Requires buildings over 75' (generally greater than 7-8 stories) in height to have automatic sprinkler systems installed throughout. The 2012 LSC allows 12-years from when the authority having jurisdiction (which in this case is CMS) officially adopts the 2012 LSC for existing facilities to comply. Therefore, those facilities that are not already required to do so have 12 years following publication of the final rule to install sprinklers. 18.2.2.2.5.2 and 19.2.2.2.5.2--Door Locking: Requires that, where the special needs of patients require specialized protective measures for their safety, door-locking arrangements are permitted. o Allows interior doors to be locked subject to the following: (1) all staff must have keys; (2) smoke detection systems must be in place; (3) the facility must be fully sprinklered; (4) the locks are electrical locks that will release upon loss of power; and (5) the locks release by independent activation of the smoke detection system and the water flow in the automatic sprinkler system. 18.3.2.6 and 19.3.2.6--Alcohol Based Hand Rubs (ABHRs) o Explicitly allows aerosol dispensers in addition to gel hand rub dispensers. Aerosol dispensers are subject to limitations on size, quantity, and location. o Automatic dispensers are now permitted in health care facilities, provided the following requirements are met: (1) They do not release contents unless activated; (2) activation occurs only when an object is within 4 of the sensing device; (3) any object placed in the activation zone and left in place must not cause more than 1 activation; (4) the dispenser must not dispense more than the amount required consistent with the label instructions; (5) the dispenser is designed, constructed and operated in a way to minimize accidental or malicious dispensing; (6) all

dispensers are tested in accordance with the manufacturer's care and use instructions each time a new refill is installed. o Defines prior language regarding above or adjacent to an ignition source'' as being within 1 inch of the ignition source. 18.3.5 and 19.3.5--Extinguishment Requirements: Requires evacuation or an approved fire watch when a sprinkler system is out of service for more than 10 hours in a 24-hour period until it is returned to service. 18.2.3.4 and 19.2.3.4 Corridors: Allows wheeled equipment in use, medical emergency equipment not in use, and patient lift and transportation equipment to be stored in corridors for more timely patient care. This provision also allows placement of fixed furniture in corridors to create resting points for patients and families and a more home-like setting as long as it does not obstruct accessible routes required by the ADA. Sections 18.3.2.5.3 and 19.3.2.5.3--Cooking Facilities o Cooking facilities are allowed in a smoke compartment where food is prepared for 30 or fewer individuals (by bed count). o The cooking facility is permitted to be open to the corridor, provided the following conditions are met: the area being served is 30 beds or less; separated from other portions of the facility by a smoke barrier; and the range hood and stovetop meet certain standards-- o A switch must be located in the area used to deactivate the cook top or range whenever the kitchen is not under staff supervision; o The switch also has a timer, not exceeding 120-minute capacity that automatically shuts off after time runs out; o 2 smoke detectors must be located no closer than 20 feet and not further than 25 feet from the cooktop or range. 18.7.5.1 and 19.7.5.1--Furnishings & Decorations o Allows combustible decor in any health care occupancy as long as they are flameretardant or treated with approved fire-retardant coating that is listed and labeled, and meet fire test standards. o Decor may not exceed--(1) 20% of the wall, ceiling and doors in any room that is not protected by an approved automatic sprinkler system; (2) 30% of the wall, ceiling and doors in any room not protected by an approved, supervised automatic sprinkler system; and (3) 50% of the wall, ceiling and doors in any room with a capacity of 4 people not protected by an approved, supervised automatic sprinkler system. 18.5.2.3 and 19.5.2.3 Fireplaces: Allows direct-vent gas fireplaces in smoke compartments without the 1 hour fire wall rating. Fireplaces must not be located inside of any patient sleeping room. Solid fuel-burning fireplaces are permitted and can be used only in areas other than patient sleeping rooms, and must be separated from sleeping rooms by construction of no less than a 1 hour fire resistance wall rating.

Outside Window or Door Requirements o The 2000 LSC required every health care occupancy patient sleeping room to have an outside window or door, with new health care occupancies having an allowable sill height not to exceed 36 above the floor with certain exceptions. This requirement does not exist in the 2012 LSC; however, as outside windows and doors may be used for smoke control, building entry, patient and resident evacuation, and other emergency operations, CMS is retaining this requirement for facilities built after the effective date of this final rule, i.e., new construction, with the following exceptions: Newborn nurseries and rooms intended for occupancy for less than 24 hours have no sill height requirements; Windows in atrium walls shall be considered outside windows for the purposes of this requirement; The window sill height in special nursing care areas shall not exceed 60 inches above the floor. Waiver Authority CMS will retain existing authority to waive provisions of the LSC under certain circumstances. A waiver may be granted for a specific LSC requirement if it is determined that-- (1) the waiver would not adversely affect patient/staff health and safety; and (2) it would impose an unreasonable hardship on the facility to meet a specific LSC requirement. In cases where a provider/supplier is cited for a LSC deficiency, a waiver recommendation may be requested from the State Survey Agency (SA) or Accrediting Organization (AO) with a CMS-approved Medicare and applicable Medicaid accreditation program. The CMS Regional Office will review the waiver request and recommendation and make a final decision. Fire Safety Evaluation System (FSES): CMS retains authority to apply the Fire Safety Evaluation System (FSES) option within the LSC as an alternative approach to meeting the requirements of the LSC. NFPA 99 The 2012 edition of the NFPA 99, Health Care Facilities Code'', addresses requirements for both health care occupancies and ambulatory care occupancies, and serves as a resource for those who are responsible for protecting health care facilities from fire and associated hazards. The purpose of this Code is to provide minimum requirements for the installation, inspection, testing, maintenance, performance, and safe practices for health care facility materials, equipment and appliances. NFPA 99 applies specific requirements based on results of a risk-based assessment methodology; this allows for application of requirements based upon the types of treatment and services being provided rather than type of facility. In order to ensure the minimum level of protection afforded by NFPA 99, it is applicable to all patient and resident care areas within a health care facility.

CMS is adopting the 2012 NFPA 99, with certain exceptions [chapters 7, 8, 12, and 13]. Key provisions include: o Chapter 4: Provides guidance on how to apply NFPA 99 to health care facilities based upon categories'' determined when using a risk-based methodology. There are 4 categories based on treatment and services provided: o #1: Facility systems in which failure of such equipment or system is likely to cause major injury or death of patients or caregivers...'' E.Gs of major injury are amputation or a burn to the eye. o #2: Facility systems in which failure of such equipment is likely to cause minor injury to patients or caregivers...'' A minor injury is one that is not serious or involving risk of life. o #3: Facility systems in which failure of such equipment is not likely to cause injury to patients or caregivers, but can cause patient discomfort '' o #4: Facility systems in which failure of such equipment would have no impact on patient care '' Each health care or ambulatory occupancy will define and implement its risk assessment methodology and document the results. CMS will not require submission of risk assessment methodologies or the use of any particular risk assessment procedure, but will confirm via the onsite survey that risk assessment methodologies are being used. Chapter 5-Gas and Vacuum Systems. Addresses the ability of oxygen and nitrous oxide to exacerbate fires, safety concerns from the storage and use of pressurized gas, and the reliance upon medical gas and vacuum systems for patient care. If such systems are installed they must comply with NFPA 99. Chapter 6-Electrical Systems. Addresses hazards related to the electrical power distribution systems in health care facilities, and issues such as electrical shock, power continuity, fire, electrocution, and explosions that might be caused by faults in the electrical system. Chapter 9-Heating, Ventilation, and Air Conditioning (HVAC). Requires HVAC systems serving spaces to be in accordance with the American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 170- Ventilation of Health Care Facilities (2008 edition) (http://www.ashrae.org). Chapter 9 applies to new construction, and altered, renovated, or modernized portions of existing systems or individual components. Chapter 10--Electrical Equipment. Covers performance, maintenance, and testing of electrical equipment. Much applies to requirements for portable electrical equipment, but also included are requirements for fixed-equipment and information on administrative issues. Chapter 11-Gas Equipment. Addresses general fire, explosions, and mechanical issues associated with gas equipment, including compressed gas cylinders. Chapter 14-Hyperbaric Facilities. Addresses hazards associated with hyperbaric facilities in health care facilities, including electrical, explosive, implosive, and fire hazards. Many requirements are applicable only to new construction. Chapter 15-Features of Fire Protection. Covers the performance, maintenance, and testing of fire protection equipment in health care facilities. Hospice / PACE / LTC Facilities

Due to similar content and regulatory structure, most of the information repeats for these providers. o All would retain requirements related to the prohibition of roller latches. o All propose modifications specific to ABHRs consistent with the 2012 LSC. o All would require evacuation or fire watch when a sprinkler system is out of service for more than 10 hrs in a 24 hr period until the system is back in service. o All would retain the 36 window sill for facilities built after the effective date of this final rule, i.e., new construction. o All add compliance with NFPA 99. o Waivers would be allowed consistent with current requirements/procedures. Hospice: Condition of Participation: Hospices that Provide Inpatient Care (418.110)\ Programs of All-Inclusive Care for the Elderly (PACE): CoP: Physical Environment (460.72) PACE providers would continue to be required to meet LSC specifications for the type of facilities in which the programs are located (that is, hospitals, and office buildings). Long-Term Care Facilities: CoP: Physical Environment (Sec. 483.70)