February 19, 2010 Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN 55102 RE: Farnsworth Aerospace Magnet Asbestos Inspection Project #0924022 Dear Ted, Enclosed please find the inspection report for the above-referenced location. If you have any questions or require additional information, please do not hesitate to contact me. Sincerely,, INC. Jeff Carlson Director of Inspection Services JC/wb 021910 Enclosures cc File
ASBESTOS INSPECTION PROFILE Farnsworth Aerospace Magnet 1290 Arcade Street Saint Paul, MN 55106 Submitted to: Ted Sherman Saint Paul Public Schools Submitted by: Institute for Environmental Assessment 9201 West Broadway North, Suite 600 Brooklyn Park, MN 55445-1922 763-315-7900 / 800-233-9513 Client #2001 Project #0924022
INDEX SECTION I Asbestos Summary and Inspection Report SECTION II Floor Plans SECTION III Asbestos Laboratory Report SECTION IV Asbestos Inspector and Management Planner Licenses
SECTION I Asbestos Summary and Inspection Report
Asbestos Summary Farnsworth Aerospace Magnet 1290 Arcade Street Saint Paul, MN 55106 On February 8, 2010, an inspection for asbestos-containing materials (ACM) was performed at the above-referenced location. The scope of the inspection included all accessible suspect ACM within the building. Since this was a limited inspection, there may be additional materials not identified on the report located within wall cavities, pipe chases and/or other inaccessible locations. Suspect ACM was identified and sampled for asbestos content. Identified materials confirmed to be ACM include the following: Black dampproofing The following suspect materials were not sampled as part of the inspection. These materials are assumed to contain asbestos and shall be treated as ACM or sampled prior to disturbance to determine if they are ACM or not. Identified materials assumed to be ACM include the following: Millboard pipe insulation and associated mudded fittings Boiler refractory Fire doors Wood floor mastic/felt/vapor barrier Chalkboard adhesive Corkboard adhesive See the attached report for specific quantities and locations. Destructive sampling was not performed as a part of this inspection. This inspection does not meet the requirements of the Minnesota Pollution Control Agency (MPCA) or Minnesota OSHA (MNOSHA) for an asbestos demolition/renovation inspection. Bulk Samples of accessible suspect material were collected and analyzed in accordance with Environmental Protection Agency (EPA) sampling and analytical procedure requirements. Sampling was conducted in a manner determined by the inspector to be sufficient to identify whether the suspect materials are asbestos containing. Where deemed appropriate, prior sample results were used and are referenced in the report. Roof samples were not collected as part of this inspection. Suspect roofing materials should be handled as asbestos or sampled prior to disturbance to determine if they are ACM or not. Specific locations of these materials, as well as those suspect materials which were analyzed and were found not to contain asbestos, are identified in the attached report., INC. 2010 Page 1 of 1
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Chart B - Assessment of Asbestos-Containing Building Materials (ACBM) All asbestos-containing events listed here are to be inspected during each six-month periodic surveillance inspection for changes in condition. The Institute for Environmental Assessment () highly recommends an in depth "front end" inspection prior to any general renovation or remodeling to determine if those activities may disrupt building materials that may involve existing or undiscovered asbestos. Potentially inaccessible or exempt asbestos-containing materials not included in this plan may include: adhesives, caulking, putty, woven blankets, curtains, gloves and gaskets, electrical wiring insulation and heat shields above lights, paints and coatings, roofing felts, flashings and shingles, and mineral core fire doors. Damaged materials which require corrective action to reduce a potential hazard are indicated on Chart A. All non-damaged ACBM identified in Chart B should be monitored through scheduled inspections and removed prior to renovation or demolition activities, or when their condition deteriorates. District administration will direct another formal inspection by a federally certified inspector within three (3) years, and will maintain an ongoing file for each building. Specific recommendations on how to manage the different types of asbestos-containing material are identified in the Asbestos Management Plan. PLEASE NOTE: Based on EPA recommendations, materials analyzed utilizing PLM and found to contain between 0% and 10% should be assumed asbestos containing unless building owner wishes the laboratory to utilize "point counting." For samples analyzed prior to 1994 containing 1% or less (trace) of asbestos, resampling utilizing the 1993 EPA Test Method or point counting is strongly recommended for purposes of demolition or renovation before treating these materials as non-asbestos containing. Contact your local office for questions or additional information. EPA ASSESSMENT CATEGORIES: 1 = Damaged or significantly damaged TSI ACM. 5 = ACBM w/potential for damage. 2 = Damaged friable surfacing ACM. 6 = ACBM w/potential for significant damage. 3 = Significantly damaged friable surfacing ACM. 7 = Any remaining friable ACBM or friable suspected ACBM. 4 = Damaged or significantly damaged friable miscellaneous ACM. Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 8 P0A Fire Door THROUGHOUT 1ST FLOOR HALLWAY 160 Sq. Ft. N ASSUMED 5 Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) EIGHT (8) DOORS. 14 X0A Miscellaneous Material ELEVATOR MECHANICAL ROOM (117) 2 Sq. Ft. N 15 CH 5 Black Dampproofing NORTH LOWER WALL. Farnsworth Aerospace Magnet Page 1
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 15 P0A Fire Door ELEVATOR MECHANICAL ROOM (117) 20 Sq. Ft. N ASSUMED 5 Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) ONE (1) DOOR. 19 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 101 750 Sq. Ft. N ASSUMED 5 1922 Original Building 20 X0C Miscellaneous Material ROOM 101 60 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) NORTH WALL BEHIND NEW CHALKBOARD. 23 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 102 750 Sq. Ft. N ASSUMED 5 1922 Original Building UNDER CARPET. 26 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 103 750 Sq. Ft. N ASSUMED 5 1922 Original Building 29 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 104 750 Sq. Ft. N ASSUMED 5 1922 Original Building 32 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 105 750 Sq. Ft. N ASSUMED 5 1922 Original Building 33 X0B Miscellaneous Material ROOM 105 10 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 34 X0C Miscellaneous Material ROOM 105 50 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) Farnsworth Aerospace Magnet Page 2
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 50 B2A Millboard Pipe Insulation THROUGHOUT 1924 ADDITION 40 Lin. Ft. N ASSUMED 5 1924 Addition ESTIMATED IN WALL CHASES. CONDITION UNKNOWN. 51 A2A Mudded Pipe Joints on Millboard Insulation THROUGHOUT 1924 ADDITION 8 Joints N ASSUMED 5 1924 Addition ESTIMATED IN WALL CHASES. CONDITION UNKNOWN. 54 X0I Miscellaneous Material ROOM 110 15 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1924) 55 X0E Miscellaneous Material ROOM 110 60 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1924) 56 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 110 350 Sq. Ft. N ASSUMED 5 1924 Addition 58 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 106 750 Sq. Ft. N ASSUMED 5 1924 Addition 59 X0I Miscellaneous Material ROOM 106 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1924) 60 X0E Miscellaneous Material ROOM 106 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1924) 64 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 109 240 Sq. Ft. N ASSUMED 5 1924 Addition Farnsworth Aerospace Magnet Page 3
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 65 X0I Miscellaneous Material ROOM 109 5 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1924) 66 X0E Miscellaneous Material ROOM 109 30 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1924) 78 P0A Fire Door NORTH ENTRY NEAR CUSTODIAL OFFICE 20 Sq. Ft. N ASSUMED 5 Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) ONE (1) DOOR. 82 D2A Interior Boiler Insulation BOILER ROOM (128) 60 Sq. Ft. N ASSUMED 5 Interior Refractory TWO (2) BOILERS. 89 P0A Fire Door THROUGHOUT 2ND FLOOR HALLWAY 80 Sq. Ft. N ASSUMED 5 Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) FOUR (4) DOORS. 90 X0B Miscellaneous Material ROOM 200 10 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 91 X0C Miscellaneous Material ROOM 200 60 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 92 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 200 300 Sq. Ft. N ASSUMED 5 1922 Original Building 94 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 202 750 Sq. Ft. N ASSUMED 5 1922 Original Building Farnsworth Aerospace Magnet Page 4
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 95 X0B Miscellaneous Material ROOM 202 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 96 X0C Miscellaneous Material ROOM 202 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 98 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 201 500 Sq. Ft. N ASSUMED 5 1922 Original Building 99 X0B Miscellaneous Material ROOM 201 15 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 100 X0C Miscellaneous Material ROOM 201 60 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 103 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 203 750 Sq. Ft. N ASSUMED 5 1922 Original Building 104 X0B Miscellaneous Material ROOM 203 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 105 X0C Miscellaneous Material ROOM 203 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 107 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 204 750 Sq. Ft. N ASSUMED 5 1922 Original Building Farnsworth Aerospace Magnet Page 5
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 108 X0B Miscellaneous Material ROOM 204 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 109 X0C Miscellaneous Material ROOM 204 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 113 P0A Fire Door MECHANICAL ROOM 225 20 Sq. Ft. N ASSUMED 5 Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) ONE (1) DOOR. 117 S0A Wood Floor Mastic / Felt / Vapor Barrier MEDIA CENTER (210) 1500 Sq. Ft. N ASSUMED 5 1922 Original Building UNDER CARPET. SOUTH END. 118 S0B Wood Floor Mastic / Felt / Vapor Barrier MEDIA CENTER (210) 450 Sq. Ft. N ASSUMED 5 1924 Addition NORTH END. UNDER CARPET. 122 X0I Miscellaneous Material ROOM 207 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1924) 123 X0E Miscellaneous Material ROOM 207 80 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1924) 125 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 207 750 Sq. Ft. N ASSUMED 5 1924 Addition UNDER CARPET. 126 S0B Wood Floor Mastic / Felt / Vapor Barrier SERVER ROOM TA10 90 Sq. Ft. N ASSUMED 5 1924 Addition Farnsworth Aerospace Magnet Page 6
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 161 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 314 750 Sq. Ft. N ASSUMED 5 1924 Addition 164 S0B Wood Floor Mastic / Felt / Vapor Barrier ROOM 309 750 Sq. Ft. N ASSUMED 5 1924 Addition 167 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 308 250 Sq. Ft. N ASSUMED 5 1922 Original Building 171 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 307 750 Sq. Ft. N ASSUMED 5 1922 Original Building 172 X0B Miscellaneous Material ROOM 307 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 173 X0C Miscellaneous Material ROOM 307 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 175 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 305 750 Sq. Ft. N ASSUMED 5 1922 Original Building 176 X0B Miscellaneous Material ROOM 305 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 177 X0C Miscellaneous Material ROOM 305 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) Farnsworth Aerospace Magnet Page 7
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 179 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 304 750 Sq. Ft. N ASSUMED 5 1922 Original Building 180 X0B Miscellaneous Material ROOM 304 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 181 X0C Miscellaneous Material ROOM 304 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 183 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 301 750 Sq. Ft. N ASSUMED 5 1922 Original Building 184 X0B Miscellaneous Material ROOM 301 5 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 185 X0C Miscellaneous Material ROOM 301 180 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) 187 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 303 750 Sq. Ft. N ASSUMED 5 1922 Original Building 188 X0B Miscellaneous Material ROOM 303 20 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 189 X0C Miscellaneous Material ROOM 303 230 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) Farnsworth Aerospace Magnet Page 8
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Event No. Material Type Location Estimated Amount Total Friable? % Asbestos EPA Assess. Category 191 S0A Wood Floor Mastic / Felt / Vapor Barrier ROOM 302 750 Sq. Ft. N ASSUMED 5 1922 Original Building 192 X0B Miscellaneous Material ROOM 302 10 Sq. Ft. N ASSUMED 5 Wood Frame Chalkboard Adhesive (1922) 193 X0C Miscellaneous Material ROOM 302 40 Sq. Ft. N ASSUMED 5 Wood Frame Corkboard Adhesive (1922) Farnsworth Aerospace Magnet Page 9
Farnsworth Aerospace Magnet 1290 Arcade Street, Saint Paul, MN 55106 Inspection Dates: 2/8/2010 Chart C - All Materials List The following list contains all events observed by the inspector, whether or not they actually contained asbestos, and are grouped by homogeneous area (material type). Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount A2A B2A D1A D2A H1A Mudded Pipe Joints on Millboard Insulation 1924 Addition Millboard Pipe Insulation 1924 Addition Boiler Gaskets White, Shiny Interior Boiler Insulation Interior Refractory Sprayed-On Structural Fireproofing Light Blue, Fluffy (2004) Total Amount: 8 Joints 51 THROUGHOUT 1924 ADDITION ASSUMED 8 Joints Total Amount: 40 Lin. Ft. 50 THROUGHOUT 1924 ADDITION ASSUMED 40 Lin. Ft. Total Amount: 4 Sq. Ft. 81 BOILER ROOM (128) NONE DETECTED 020810ML-11 4 Sq. Ft. Total Amount: 60 Sq. Ft. 82 BOILER ROOM (128) ASSUMED 60 Sq. Ft. Total Amount: 600 Sq. Ft. 141 HALLWAY BETWEEN ROOMS 310 & 313 NONE DETECTED 020810ML-35,36 50 Sq. Ft. 144 ROOM 310 NONE DETECTED 200 Sq. Ft. 149 ROOM 311 NONE DETECTED 020810ML-35,36 100 Sq. Ft. 152 ROOM 312 NONE DETECTED 50 Sq. Ft. 155 ROOM 313 NONE DETECTED 020810ML-34 200 Sq. Ft. Farnsworth Aerospace Magnet Page 1
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount I3A 2' x 4' Ceiling Tile Widthwise Slits & Pin Holes (1992) Total Amount: 14,915 Sq. Ft. 9 HALLWAY OUTSIDE ROOMS 111 & 112 NONE DETECTED 200 Sq. Ft. 10 ROOM 111 NONE DETECTED 145 Sq. Ft. 12 GYMNASIUM OFFICE (118) NONE DETECTED 85 Sq. Ft. 16 ROOM 112 NONE DETECTED 200 Sq. Ft. 36 MAIN OFFICE NONE DETECTED 720 Sq. Ft. 39 OFFICE 115 NONE DETECTED 120 Sq. Ft. 41 OFFICE 116 NONE DETECTED 190 Sq. Ft. 43 NURSE'S OFFICE (117A) NONE DETECTED 135 Sq. Ft. 47 SICK ROOM (117) NONE DETECTED 130 Sq. Ft. 52 ROOM 110 NONE DETECTED 350 Sq. Ft. 62 ROOM 109 NONE DETECTED 240 Sq. Ft. 67 HALLWAY BETWEEN ROOMS 107 & 108 NONE DETECTED 140 Sq. Ft. 70 ROOM 107 NONE DETECTED 1050 Sq. Ft. 73 ROOM 108 NONE DETECTED 1050 Sq. Ft. 76 HALLWAY 115 NONE DETECTED 70 Sq. Ft. 77 NORTH ENTRY NEAR CUSTODIAL OFFICE NONE DETECTED 200 Sq. Ft. 79 CUSTODIAL OFFICE (131) NONE DETECTED 110 Sq. Ft. 80 HALLWAY OUTSIDE BOILER ROOM NONE DETECTED 020810ML-02 80 Sq. Ft. 85 SOUTH ENTRY TO GYMNASIUM 154 NONE DETECTED 190 Sq. Ft. 86 ENTRY 135 NONE DETECTED 360 Sq. Ft. 110 ROOM 208 NONE DETECTED 640 Sq. Ft. 115 MEDIA CENTER (210) NONE DETECTED 1950 Sq. Ft. 119 MEDIA CENTER OFFICE (209) NONE DETECTED 020810ML-03 320 Sq. Ft. Farnsworth Aerospace Magnet Page 2
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount 127 HALLWAY BETWEEN ROOMS 205 & 206 NONE DETECTED 140 Sq. Ft. 129 ROOM 205 NONE DETECTED 820 Sq. Ft. 131 ROOM 216 NONE DETECTED 240 Sq. Ft. 133 ROOM 206 NONE DETECTED 820 Sq. Ft. 139 THROUGHOUT 3RD FLOOR HALLWAY NONE DETECTED 1600 Sq. Ft. 151 ROOM 312 NONE DETECTED 190 Sq. Ft. 159 ROOM 314 NONE DETECTED 750 Sq. Ft. 162 ROOM 309 NONE DETECTED 750 Sq. Ft. 165 ROOM 308 NONE DETECTED 250 Sq. Ft. 168 ROOM 315 NONE DETECTED 680 Sq. Ft. I3B I3C I3D 2' x 4' Ceiling Tile Vinyl-Covered Sheetrock 2' x 4' Ceiling Tile Widthwise Fissures w/pin Holes 2' x 4' Ceiling Tile Dents w/pin Holes Total Amount: 1,120 Sq. Ft. 84 KITCHEN AREA (143) NSM 1120 Sq. Ft. Total Amount: 2,110 Sq. Ft. 136 THROUGHOUT 3RD FLOOR HALLWAY NONE DETECTED 020810ML-29 330 Sq. Ft. 140 HALLWAY BETWEEN ROOMS 310 & 313 NONE DETECTED 140 Sq. Ft. 143 ROOM 310 NONE DETECTED 820 Sq. Ft. 154 ROOM 313 NONE DETECTED 820 Sq. Ft. Total Amount: 330 Sq. Ft. 148 ROOM 311 NONE DETECTED 020810ML-33 330 Sq. Ft. Farnsworth Aerospace Magnet Page 3
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount J3A K1A K2A K2B K2C K3A Miscellaneous Cementitious Material Black Window Sills Sheet Vinyl Flooring & Mastic Purple Terrazzo-Look 12" x 12" Vinyl Floor Tile & Mastic Gray w/black Specks 12" x 12" Vinyl Floor Tile & Mastic Tan Mottle 12" x 12" Vinyl Floor Tile & Mastic Pink Mottle Miscellaneous Flooring Black Floor Tile Mastic Total Amount: 15 Sq. Ft. 146 ROOM 310 NONE DETECTED 5 Sq. Ft. 157 ROOM 313 NONE DETECTED 020810ML-32 10 Sq. Ft. Total Amount: 130 Sq. Ft. 48 SICK ROOM (117) NONE DETECTED 020810ML-09 130 Sq. Ft. Total Amount: 4,775 Sq. Ft. 13 GYMNASIUM OFFICE (118) NONE DETECTED 020810ML-04 85 Sq. Ft. 83 GYMNASIUM (133) NONE DETECTED 4500 Sq. Ft. 153 ROOM 312 NONE DETECTED 190 Sq. Ft. Total Amount: 135 Sq. Ft. 44 NURSE'S OFFICE (117A) NONE DETECTED 020810ML-08 135 Sq. Ft. Total Amount: 820 Sq. Ft. 134 ROOM 206 NONE DETECTED 020810ML-28 820 Sq. Ft. Total Amount: 2,850 Sq. Ft. 7 THROUGHOUT 1ST FLOOR HALLWAY NONE DETECTED 950 Sq. Ft. 88 THROUGHOUT 2ND FLOOR HALLWAY NONE DETECTED 020810ML-06 ML-06: HALLWAY NEAR ROOM 207. 950 Sq. Ft. 138 THROUGHOUT 3RD FLOOR HALLWAY NONE DETECTED 950 Sq. Ft. Farnsworth Aerospace Magnet Page 4
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount K3B M0A M0B N0A Miscellaneous Flooring 2' x 2' Blue Raised Circles Stair Treads Plaster 1922 Original Building Plaster 1924 Addition Drywall/Joint Compound Total Amount: 500 Sq. Ft. 69 NORTH STAIRWELL NONE DETECTED 020810ML-26 500 Sq. Ft. 5 THROUGHOUT 1922 ORIGINAL BUILDING NONE DETECTED 020810ML-12,13,14,15,16,1 7; 458-1 49 THROUGHOUT 1924 ADDITION NONE DETECTED 020810ML-18,19,20,21,22;4 58-2 Total Amount: 20,000 Sq. Ft. ML-12: CUSTODIAL CLOSET NEAR ROOM 305. ML-13: MEDIA CENTER. ML-14: MAIN OFFICE. ML-15: ROOM 201. ML-16: ROOM 307. ML-17: ROOM 301. 458-1: ROOM 103. ML-18: ROOM 309. ML-19: 3RD FLOOR HALLWAY. ML-20: SERVER ROOM. ML-21: MEDIA OFFICE. ML-22: ROOM 109. 458-2: ROOM 106. 20000 Sq. Ft. Total Amount: 3,000 Sq. Ft. 3000 Sq. Ft. Total Amount: 10,000 Sq. Ft. 1 THROUGHOUT BUILDING NONE DETECTED 020810ML-23; 509N7 ML-23: BOILER ROOM. N7: ROOM 11. 10000 Sq. Ft. P0A Q0A Fire Door Metal - 1-1/2 Hr Rating (Underwriter's Laboratories) Carpet Mastic Purple Carpet Total Amount: 300 Sq. Ft. 8 THROUGHOUT 1ST FLOOR HALLWAY ASSUMED 160 Sq. Ft. 15 ELEVATOR MECHANICAL ROOM (117) ASSUMED 20 Sq. Ft. 78 NORTH ENTRY NEAR CUSTODIAL OFFICE ASSUMED 20 Sq. Ft. 89 THROUGHOUT 2ND FLOOR HALLWAY ASSUMED 80 Sq. Ft. 113 MECHANICAL ROOM 225 ASSUMED 20 Sq. Ft. Total Amount: 20,565 Sq. Ft. 11 ROOM 111 NONE DETECTED 145 Sq. Ft. 17 ROOM 112 NONE DETECTED 200 Sq. Ft. 18 ROOM 101 NONE DETECTED 750 Sq. Ft. 22 ROOM 102 NONE DETECTED 750 Sq. Ft. Farnsworth Aerospace Magnet Page 5
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount 25 ROOM 103 NONE DETECTED 750 Sq. Ft. 37 MAIN OFFICE NONE DETECTED 720 Sq. Ft. 40 OFFICE 115 NONE DETECTED 120 Sq. Ft. 42 OFFICE 116 NONE DETECTED 190 Sq. Ft. 53 ROOM 110 NONE DETECTED 350 Sq. Ft. 57 ROOM 106 NONE DETECTED 750 Sq. Ft. 63 ROOM 109 NONE DETECTED 240 Sq. Ft. 68 HALLWAY BETWEEN ROOMS 107 & 108 NONE DETECTED 140 Sq. Ft. 71 ROOM 107 NONE DETECTED 1050 Sq. Ft. 74 ROOM 108 NONE DETECTED 1050 Sq. Ft. 93 ROOM 202 NONE DETECTED 020810ML-01 750 Sq. Ft. 97 ROOM 201 NONE DETECTED 1200 Sq. Ft. 102 ROOM 203 NONE DETECTED 750 Sq. Ft. 106 ROOM 204 NONE DETECTED 750 Sq. Ft. 111 ROOM 208 NONE DETECTED 640 Sq. Ft. 116 MEDIA CENTER (210) NONE DETECTED 1950 Sq. Ft. 120 MEDIA CENTER OFFICE (209) NONE DETECTED 320 Sq. Ft. 124 ROOM 207 NONE DETECTED 750 Sq. Ft. 130 ROOM 205 NONE DETECTED 820 Sq. Ft. 160 ROOM 314 NONE DETECTED 750 Sq. Ft. 163 ROOM 309 NONE DETECTED 750 Sq. Ft. 166 ROOM 308 NONE DETECTED 250 Sq. Ft. 169 ROOM 315 NONE DETECTED 680 Sq. Ft. 170 ROOM 307 NONE DETECTED 750 Sq. Ft. 174 ROOM 305 NONE DETECTED 750 Sq. Ft. Farnsworth Aerospace Magnet Page 6
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount 178 ROOM 304 NONE DETECTED 750 Sq. Ft. 186 ROOM 303 NONE DETECTED 750 Sq. Ft. Q0B Q0C Q0D R0A Carpet Mastic Brown Carpet Carpet Mastic Blue Carpet Carpet Mastic Multi-Colored Berber Carpet Baseboard/Mopboard Adhesive 4" Maroon Baseboard Total Amount: 6,640 Sq. Ft. 6 THROUGHOUT 1ST FLOOR HALLWAY NONE DETECTED 1800 Sq. Ft. 28 ROOM 104 NONE DETECTED 2001-1901-XX-26B 750 Sq. Ft. 87 THROUGHOUT 2ND FLOOR HALLWAY NONE DETECTED 1600 Sq. Ft. 128 HALLWAY BETWEEN ROOMS 205 & 206 NONE DETECTED 140 Sq. Ft. 137 THROUGHOUT 3RD FLOOR HALLWAY NONE DETECTED 1600 Sq. Ft. 182 ROOM 301 NONE DETECTED 750 Sq. Ft. Total Amount: 1,500 Sq. Ft. 31 ROOM 105 NONE DETECTED 020810ML-25 750 Sq. Ft. 190 ROOM 302 NONE DETECTED 750 Sq. Ft. Total Amount: 2,110 Sq. Ft. 142 HALLWAY BETWEEN ROOMS 310 & 313 NONE DETECTED 140 Sq. Ft. 145 ROOM 310 NONE DETECTED 820 Sq. Ft. 150 ROOM 311 NONE DETECTED 330 Sq. Ft. 156 ROOM 313 NONE DETECTED 020810ML-31 820 Sq. Ft. Total Amount: 20 Sq. Ft. 45 NURSE'S OFFICE (117A) NONE DETECTED 2001-1901-XX-28B 20 Sq. Ft. Farnsworth Aerospace Magnet Page 7
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount S0A S0B Wood Floor Mastic / Felt / Vapor Barrier 1922 Original Building Wood Floor Mastic / Felt / Vapor Barrier 1924 Addition Total Amount: 13,050 Sq. Ft. 19 ROOM 101 ASSUMED 750 Sq. Ft. 23 ROOM 102 ASSUMED 750 Sq. Ft. 26 ROOM 103 ASSUMED 750 Sq. Ft. 29 ROOM 104 ASSUMED 750 Sq. Ft. 32 ROOM 105 ASSUMED 750 Sq. Ft. 92 ROOM 200 ASSUMED 300 Sq. Ft. 94 ROOM 202 ASSUMED 750 Sq. Ft. 98 ROOM 201 ASSUMED 500 Sq. Ft. 103 ROOM 203 ASSUMED 750 Sq. Ft. 107 ROOM 204 ASSUMED 750 Sq. Ft. 117 MEDIA CENTER (210) ASSUMED 1500 Sq. Ft. 167 ROOM 308 ASSUMED 250 Sq. Ft. 171 ROOM 307 ASSUMED 750 Sq. Ft. 175 ROOM 305 ASSUMED 750 Sq. Ft. 179 ROOM 304 ASSUMED 750 Sq. Ft. 183 ROOM 301 ASSUMED 750 Sq. Ft. 187 ROOM 303 ASSUMED 750 Sq. Ft. 191 ROOM 302 ASSUMED 750 Sq. Ft. Total Amount: 4,130 Sq. Ft. 56 ROOM 110 ASSUMED 350 Sq. Ft. 58 ROOM 106 ASSUMED 750 Sq. Ft. 64 ROOM 109 ASSUMED 240 Sq. Ft. Farnsworth Aerospace Magnet Page 8
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount V0A Sink Undercoating Gray 118 MEDIA CENTER (210) ASSUMED 450 Sq. Ft. 125 ROOM 207 ASSUMED 750 Sq. Ft. 126 SERVER ROOM TA10 ASSUMED 90 Sq. Ft. 161 ROOM 314 ASSUMED 750 Sq. Ft. 164 ROOM 309 ASSUMED 750 Sq. Ft. Total Amount: 112 Sq. Ft. 21 ROOM 101 NONE DETECTED 6 Sq. Ft. 24 ROOM 102 NONE DETECTED 6 Sq. Ft. 27 ROOM 103 NONE DETECTED 6 Sq. Ft. 30 ROOM 104 NONE DETECTED 6 Sq. Ft. 35 ROOM 105 NONE DETECTED 6 Sq. Ft. 38 MAIN OFFICE NONE DETECTED 4 Sq. Ft. 46 NURSE'S OFFICE (117A) NONE DETECTED 6 Sq. Ft. 61 ROOM 106 NONE DETECTED 020810ML-07 6 Sq. Ft. 72 ROOM 107 NONE DETECTED 6 Sq. Ft. 75 ROOM 108 NONE DETECTED 6 Sq. Ft. 101 ROOM 201 NONE DETECTED 16 Sq. Ft. 112 ROOM 208 NONE DETECTED 8 Sq. Ft. 121 MEDIA CENTER OFFICE (209) NONE DETECTED 4 Sq. Ft. 132 ROOM 216 NONE DETECTED 4 Sq. Ft. 135 ROOM 206 NONE DETECTED 10 Sq. Ft. 147 ROOM 310 NONE DETECTED 6 Sq. Ft. 158 ROOM 313 NONE DETECTED 6 Sq. Ft. Farnsworth Aerospace Magnet Page 9
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount X0A X0B X0C Miscellaneous Material Black Dampproofing Miscellaneous Material Wood Frame Chalkboard Adhesive (1922) Miscellaneous Material Wood Frame Corkboard Adhesive (1922) Total Amount: 2 Sq. Ft. 14 ELEVATOR MECHANICAL ROOM (117) 15 CH 020810ML-05 2 Sq. Ft. Total Amount: 190 Sq. Ft. 33 ROOM 105 ASSUMED 10 Sq. Ft. 90 ROOM 200 ASSUMED 10 Sq. Ft. 95 ROOM 202 ASSUMED 20 Sq. Ft. 99 ROOM 201 ASSUMED 15 Sq. Ft. 104 ROOM 203 ASSUMED 20 Sq. Ft. 108 ROOM 204 ASSUMED 20 Sq. Ft. 172 ROOM 307 ASSUMED 20 Sq. Ft. 176 ROOM 305 ASSUMED 20 Sq. Ft. 180 ROOM 304 ASSUMED 20 Sq. Ft. 184 ROOM 301 ASSUMED 5 Sq. Ft. 188 ROOM 303 ASSUMED 20 Sq. Ft. 192 ROOM 302 ASSUMED 10 Sq. Ft. Total Amount: 2,060 Sq. Ft. 20 ROOM 101 ASSUMED 60 Sq. Ft. 34 ROOM 105 ASSUMED 50 Sq. Ft. 91 ROOM 200 ASSUMED 60 Sq. Ft. 96 ROOM 202 ASSUMED 230 Sq. Ft. 100 ROOM 201 ASSUMED 60 Sq. Ft. 105 ROOM 203 ASSUMED 230 Sq. Ft. 109 ROOM 204 ASSUMED 230 Sq. Ft. Farnsworth Aerospace Magnet Page 10
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount 173 ROOM 307 ASSUMED 230 Sq. Ft. 177 ROOM 305 ASSUMED 230 Sq. Ft. 181 ROOM 304 ASSUMED 230 Sq. Ft. 185 ROOM 301 ASSUMED 180 Sq. Ft. 189 ROOM 303 ASSUMED 230 Sq. Ft. 193 ROOM 302 ASSUMED 40 Sq. Ft. X0D X0E X0F X0G Miscellaneous Material Brown Ductwork Seam Caulk Miscellaneous Material Wood Frame Corkboard Adhesive (1924) Miscellaneous Material Red Fire Stop Miscellaneous Material AHU Seam Tar Total Amount: 200 Sq. Ft. 2 THROUGHOUT BUILDING NONE DETECTED 020810ML-10 ML-10: MEDIA CENTER. 200 Sq. Ft. Total Amount: 400 Sq. Ft. 55 ROOM 110 ASSUMED 60 Sq. Ft. 60 ROOM 106 ASSUMED 230 Sq. Ft. 66 ROOM 109 ASSUMED 30 Sq. Ft. 123 ROOM 207 ASSUMED 80 Sq. Ft. Total Amount: 100 Sq. Ft. 4 THROUGHOUT BUILDING NONE DETECTED 020810ML-24 ML-24: ROOM 109. 100 Sq. Ft. Total Amount: 10 Sq. Ft. 114 MECHANICAL ROOM 225 NONE DETECTED 020810ML-27 10 Sq. Ft. Farnsworth Aerospace Magnet Page 11
Chart C - All Materials List - Farnsworth Aerospace Magnet (cont.) Homogeneous Area ID Code (Material Type) Event No. Location % Asbestos Sample No. Sample Location Estimated Total Amount X0H X0I Miscellaneous Material Gray Duct Caulk Miscellaneous Material Wood Frame Chalkboard Adhesive (1924) Total Amount: 100 Sq. Ft. 3 THROUGHOUT BUILDING NONE DETECTED 020810ML-30 ML-30: 3RD FLOOR HALLWAY. 100 Sq. Ft. Total Amount: 60 Sq. Ft. 54 ROOM 110 ASSUMED 15 Sq. Ft. 59 ROOM 106 ASSUMED 20 Sq. Ft. 65 ROOM 109 ASSUMED 5 Sq. Ft. 122 ROOM 207 ASSUMED 20 Sq. Ft. Farnsworth Aerospace Magnet Page 12
SECTION II Floor Plans
Farnsworth Elementary - Basement TA1 B100 B101 TA2 B102
Farnsworth Elementary - First Floor 137 138 136 144 128 143 128 131A 131 132 133A 130 133 145 142 118 113A 134 135 108 115 117 118 109 110 E1 112 111 119 TA3 122 123 124 125 101 102 114 129 102A 102B 101 102 117 107 106 117A 110 TA4 105 104 103 116 115 111A
Farnsworth Elementary - Second Floor 225 206 216 207 214 E1 215 208 216A 217 218 TA8 221 TA9 201 200 208 210 201 200 TA10 JC21 209 210 204 203 202 205
Farnsworth Elementary - Third Floor 313 312 315A 314 TB1 315 317 320 321 TE21 324 TE22 301 302 312 313 302 301 JC31 311 309 308 307 306 305 304 303 310
SECTION III Asbestos Laboratory Report
SECTION IV Asbestos Inspector & Management Planner Licenses