Isolette TI500 Neonatal Transport

Similar documents
Isolette 8000 Neonatal Closed Care

MT Optimal microclimate and reliability you can depend on.

Isolette 8000 plus Neonatal Closed Care

The birth of a new era Excellent neonatal respiratory support at your fingertips DRÄGER BABYLOG VN500

MT Streamlined access to vital patient information INNOVIAN SOLUTION SUITE

On-site & Shutdown Safety Service Health and Safety Officer. Basic Information

Streamlined access to vital patient information. InnovIan SolutIon SuIte

D A refreshing advancement in high-performance thermoregulation. ISOLETTE 8000

Critical Care. at its best

Monitoring and IT Solutions for supporting patient safety and care INFINITY IN-HOSPITAL TRANSPORT SOLUTIONS

smart technologies Neonatal incubator from standard to intensive care

D Pure possibilities. Dräger perseus A500

D Bringing you closer to your patients PATIENT MONITORING AND IT SOLUTIONS

V500/VN500 Elite What does peace of mind mean to you?

Primus. Your personal anesthesia assistant. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

smart technologies Neonatal incubator from standard to intensive care

D Anesthesia Information Management DRÄGER INNOVIAN ANESTHESIA

Safe anesthesia during transplantation surgery and other interventions

At your side in intensive care

Monitoring and It solutions for supporting patient safety and care. InfInIty

Infinity Monitoring and IT Solutions

Infinity Acute Care System Patient Monitoring Solution

Setting a new standard for performance, safety and simplicity

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

ENTERPRISE with people in mind

Declaration of Classification ValiSpore Incubator Manual

More comfortable childbirth

Hill-Rom Advanta 2 Bed Tips Simply Intuitive FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE ADVANTA 2 BED, SEE USER S MANUAL.

Introduction. Welcome to Human Care.

Specifications, Performance & Submittal

Monnal T75. Tailor-made breathing.

Efficient Use of Valuable Space

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE 2A & 2B Raja S.C.Mullick Road Jadavpur, Kolkata

Eleganza 3XC. Designed for ICU

... Top Quality Assurance Bizerba CWE Checkweigher

Redefining Patient Handling. prevention

Citadel Bed Frame System

Instant results with a simple touch

MediCom. MediCom AUSTCO. State of the art Hospital Emergency Call System. The very best in nurse call and. care management solutions

Affinity Four Birthing bed Delivering Safety

Medical Grade Power Strips

SV 300 Ventilator. Compact yet powerful. Globally experienced, locally accessible

Redefining Patient Handling. prevention

Simply Practical. The Hill-Rom CareAssist ES Hospital Bed

AvantGuard bed Safety by design. Information

ConCerto Shower trolley

3M Infection Prevention Patient Warming Product Brochure. Warm. Every. Patient

New Fire Safety Rules Summary Evvie Munley, LeadingAge

Velino. by Haelvoet HOSPITAL - NURSING HOME FURNITURE

Operating Manual for HEKA Incubators

MAXI SKY 2 THE NEXT GENERATION CEILING LIFT SOLUTION

Image 3. exclusive design to meet all your needs

Birthing Bed AVE 2. Welcome to this world child

Equipment Cleaning Guidelines Template

SV 300 Ventilator. Compact yet powerful. Globally experienced, locally accessible

Because Warming Makes All The Difference

Lynn Bayne has no financial disclosures to make.

Wristbands & Labels Catalog

Simply Intuitive. The Hill-Rom Advanta 2 Bed

Instruction for use and trouble shooting guide

EasyCare Maximizing Care, Comfort and Safety

Distribution Statement A: Approved for public release; distribution is unlimited.

MMO

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

Wiring Diagrams 15/30RES 15/30RYG. Residential Generator Sets Commercial Generator Sets. Models: Controllers: Advanced Digital Control ADC 2100

Silver Plus. Manual Guns. Airless. Features and Benefits. Typical Applications. Typical Fluids Handled

Medical furniture OPTIMA OBSTETRIC BED

Providing Quality Equipment and Services for Specialized Mechanical Air Systems. Serving Kentucky and Southern Indiana for over 70 years

AMC 30% 40% 10% 20% Electric power(kw) kw 25,44. Rotation speed (rpm) rpm 40,00. Got the Cochlea to reach the maximum availability of water

B. All of the documents in this RFP form the Basis-of-Design for this project.

Ave 2 Birthing Bed. Welcome to the world

Opera. With people in mind

Wiring Diagrams RZD RZDB (Detroit Diesel Powered) Industrial Generator Sets. Models:

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

REVEAL. Patient Assistant 9538/9539. Clinician Manual. Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician.

PREMATURE INFANT INCUBATOR ALERT SYSTEM VIA SMS

Bedside cabinets and overbed tables

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

USA, LCC CATALOG 2016 USA, LCC

Environmental Monitoring in NHS Facilities

enflow IV fluid and blood warming system Vital Signs The right temperature, in the right place, at the right time

Centrella Smart+ Bed Because life-altering moments deserve elevated care

Centrella Smart+ Bed. Because life-altering moments deserve elevated care

Wiring Diagrams REOZM REOZMB. Industrial Generator Sets. Models: Controllers: Decision-Maker 550 Decision-Maker 3+ TP /07d

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Thopaz. Einführung. Welcome to the age of digital thoracic drainage therapy! «What I want... is a safe and efficient drainage therapy»

Standard Operating Procedure. for the Retrieval Nurse

Lodestar. Series. Specification Sheet. Application. Features. Floodlight. Tunnel Lighting. Parking Applications. Canopy Lighting Wash Lighting.

KEY CONSIDERATIONS: Thermal Barcoded Infant Wristbands

BariMaxx Active Therapy System

SUBCHAPTER 31. MANDATORY PHYSICAL ENVIRONMENT

Isolation Precaution (Part 2) Protective Environment (PE) Room. Combined AII/PE Rooms. Contact Isolation 5/22/2017

Wiring Diagrams 200REOZPB REOZDB 350/400REOZD 350/400REOZDC 450REOZDB. Industrial Generator Sets. Models:

Rule R Nursing Facility Construction. Table of Contents. State Links: Utah.gov State Online Services Agency List Business.utah.gov Search.

THE MODERN WORKSPACE BY ENTRAWOOD

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

WHITE PAPER HOSPITAL DESIGN AND HIPAA: The Changing Face of Patient Privacy

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

Transcription:

Isolette TI500 Neonatal Transport Transport neonates safely, comfortably and with a minimum of stress with a fully-featured, high-performance transport incubator. D-1587-2009

02 Isolette TI500 Benefits Rugged design for maximum performance The durable design of the Isolette TI500 means it can be taken nearly anywhere and still provide the warm, safe environment and quick access necessary for optimal neonate care. Built in accordance with stringent IEC and CE standards, the TI500 is low maintenance and features both easy cleaning and servicing. NICU-level care - anywhere Used in thousands of hospitals around the globe, the Isolette is an integrated, full-feature incubator solution. Caregivers can select temperature, humidity and oxygen concentration of the incubator microenvironment while the Isolette provides continuous data on the temperature of the newborn. Flexible power options The Dräger Isolette can run on 120or 240 VAC line voltage (50/60/400 Hz), 12 or 28 V DC, or internal battery power, giving users optimal flexibility during transport. Quick access to the infant The head access / slide out mattress feature allow quick and easy access to baby for intubation or CPR. Designed for safety All controls and monitors are situated in the front of the device for easy viewing and quick access. Clear view of the infant The hand-made acrylic hood is scratch resistant to maintain transparency over time, and an integrated examination light gives you high quality illumination for visual evaluation. Many options and accessories to choose from The high hood option further facilitates access to baby and provides more room for larger babies, clinical disposables (diapers, blankets, etc.) and even more uniform air flow and temperature distribution. Add an i.v. pole, a second monitor shelf or increase the offline range with an additional external battery.

Isolette TI500 03 Accessories Neonatal Care Accessories Dräger accessories for neonatal ventilation and thermotherapy ventilate gently and effectively, reduce stress and help promote the development of the newborn with a wide range of accessories designed specifically for use with the smallest of patients. D-7384-2009

04 Isolette TI500 Technical Data Physical Attributes (without options/ accessories) TI500 TI500 with 147 stand Height 20 in (50.8 cm) min- 32 in (81.3 cm) max- 44in (111.8 cm) Width 20.8 in (52.7 cm) 22.3 in (56.5 cm) Length 37.8 in (95.9 cm) 40.3 in (102 cm) Weight(1) 108.5 lbs (49.2 kg) 159 lbs (72 kg) Distance from vertical hood to mattress Low Hood 8.25 in (21 cm) High Hood 9.84 in (25 cm) Standard Features Double wall Skin temperature probe O2 inlet Examination lamp 2 access doors 2 disposable infant restraint straps 1 Iris port 2 Quiet Touch port doors 6 tubing ports Locking power control receptacles DC cable 2D or 2E size tank mounts Humidity Pad(2) The tank mount permits mounting gas cylinders with a diameter of up to 4.5 in (11.6 cm) and up to 34 in (85 cm) in length Optional Features Accessory shelf, IV pole, * High Hood, * Pressure Regulator and Flowmeter General Specifications O2 concentration range 21% to 58% minimum Humidity capacity 50% to 70% Noise level Performance Characteristics Temperature set range Temperature rise time <60 dba(3) 22.0 C - 38 C (71 F - 100 F) 30 minutes Temperature variability 1.0 C Temperature overshoot 2.0 C Temperature uniformity 1.0 C Correlation of display temperature to set point at temperature equilibrium Humidity pad Air filter Relative humidity Check calibration key 36.0 ± 0.l C Controller Displays On/standby 2.0 C in l0-20 C ambients 1.5 C in 20-30 C ambients Holds 400 ml.(14 oz) sterile distilled water with no significant spillage for up to 45 tilt in either direction. Removes >99% of airborne particles greater than 0.5 micron diameter 50 to 70% for 10-12 hours using humidity pad Illuminates when On Battery condition status 4 LED indication of battery charge condition 25-100% Power mode Illuminates AC, DC, or external DC Heater power 4 LED indication of heater power; 25-100% Baby temperature C Displays infant temperature

Isolette TI500 05 Technical Data Air temperature C Set temperature Alarm indicators Battery Specifications(4) Incubator Type Battery rating Life expectancy Charge time Displays incubator air temperature Illuminates when changing set temperature High temp, Power fail, Sensor fault, Heater temp, Air flow, Low DC 1 battery standard (2nd optional) Vented rechargeable, 12 Vdc, 24 AH gel-type battery (lead acid) Incubator maintains a differential of 25 C (77 F) between ambient and set point for 90 minutes on 1 battery or 180 min. on 2 batteries at full heater power 200 complete charge/discharge cycles minimum 10 hours per battery from full discharge Safety Alarms High temperature Actuates if incubator air temp. >39 ± 0.5 C Sensor (temperature) Heater temperature Power fail Air flow Low DC Silence/reset Actuates if sensor fails Actuates if heater temp >77 C (l70 F) Actuates if AC fails and no DC power present, and activates if unit switches from AC to DC current Actuates for fan failure Actuates if DC<10.5 Vdc, or external 28 Vdc falls below 25.5 Vdc nominal Silences the audible portion of alarms for 5 minutes, except Power fail. Resets Sensor & High Temp alarms after 100% conditions corrected. Resets intermittent power alert if unit switches from AC to DC current Environmental Storage temperature Operating range Relative Humidity Operating range -40 C to 70 C ambient Sea level to 3 km (10,000 ft.) non-pressurized environment. Sea level to 12 km (40,000 ft.)-pressurized environment 0% to 95% RH, non-condensing Electrical AC power requirements DC power requirements Observation lamp (1) Weight includes one battery (2) Humidity pad prevents spills (3) In ambients of 50 dba or less 110/120 V, 50/60/400 Hz - 220/240 V, 50/60/400 Hz 11-13 V, 200 W (max) - 26-30 V, 200 W (max) 35 footcandles - 4 inches above mattress 376 lux - 10 cm above mattress (4) TI500 will maintain a differential of 25 C (77 F) between ambient and Set point for 90 minutes (one battery) or 3 hours (two batteries). At differentials <25 C (<77 F), the TI500 maintains temperatures for longer periods Ordering Information Accessories Organizer tray for Resuscitaire slide through drawer Second Battery Option MU11132 MU05598

06 Isolette TI500 Ordering Information Accessory Shelf Standard Hood High Hood IV Pole Conversion Kit to High Hood MU05619 MU05841 MU04500 MU06094

Notes Isolette TI500 07

08 Isolette TI500 Notes 90 69 068 14-08-1 Communications & Sales Marketing PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2014 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Manufacturer: Draeger Medical Systems, Inc. 3135 Quarry Road Telford, PA 18969-1042, USA REGION EUROPE CENTRAL AND EUROPE NORTH Drägerwerk AG & Co. KGaA Moislinger Allee 53-55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE SOUTH Dräger Médical S.A.S. Parc de Haute Technologie d'antony 2 25, rue Georges Besse 92182 Antony Cedex, France Tel +33 1 46 11 56 00 Fax +33 1 40 96 97 20 dlmfr-contact@draeger.com REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA / PACIFIC Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore 609916, Singapore Tel +65 6572 4388 Fax +65 6572 4399 asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel +507 377 9100 Fax +507 377 9130 contactcsa@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact