ARROW PRESSURE INJECTABLE PICC. Expect more from your PICC

Similar documents
Arrow Pressure Injectable PICC Kit. Stay ahead of risk

Arrow Vascular Clinical Education

Arrow. Understanding Your Choice for Vascular Access. A patient guide to vascular access based on vessel health and preservation model

393 PICC INSERTION USING ULTRASONOGRAPHY AND MICRO INTRODUCER TECHNIQUE 06/10/03 1

Proven lowest catheter-related bloodstream infection rates.

Certified PICC Ultrasound Inserter CPUI Renewal Application

The Vygon range of peripherally inserted catheters provides safe and reliable vascular access.

See Policy #1302 (Nursing Student Privileges and Limitations) for full details. Central Line dressing care, declotting and discontinuation may ONLY

Technology Innovations in Vascular Access

Peripherally Inserted Central Catheter

NURSING LEADERSHIP IMPACTING CHANGE

Health Workforce Policies in OECD Countries

1. Infection Control, Centers for Disease Control and Prevention (CDC). (2002). Guideline for hand hygiene in health-care settings

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

21 st Century Health Care Consultants

Wyoming STATE BOARD OF NURSING

STANDARDIZED PROCEDURE CENTRAL LINE PLACEMENT and TEMPORARY NONTUNNELLED CENTRAL VENOUS DIALYSIS CATHETER INSERTION (Adult, Peds)

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

HHVNA Infusion Therapy MIDLINE CATHETER

ASEPTIC TECHNIQUE LEARNING PACKAGE

Compensation. Benefits. Expatriation.

Manpower Employment Outlook Survey India. A Manpower Research Report

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

Central Venous Access Devices (CVAD) Procedures

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

Having a portacath insertion in the x-ray department

Peripherally inserted central catheter (PICC line) Information to accompany consent

Healthcare Practice. Healthcare PanelBook 2017

Percutaneous Transhepatic Biliary Drainage Interventional Radiology

Peripherally Inserted Central Catheter (PICC Line)

NORTH SHORE MEDICAL CENTER NURSING PROCEDURE

Spectrum. Proven lowest catheter-related bloodstream infection rates.

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

TRENDS IN HEALTH WORKFORCE IN EUROPE. Gaétan Lafortune, OECD Health Division Conference, Brussels, 17 November 2017

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

Intravenous Medication Administration via a Central Venous Line

Limitations and Guidelines Revised for Elastomeric Devices and IV Supplies and Equipment

PICC line trends and cost effectiveness

Research on the Global Impact of the Ronald McDonald House Program

PICCs. Vascular access is the cornerstone in the. It s all about. Vascular safety:

Arrow Vascular Clinical Education

The industrial competitiveness of Italian manufacturing

Central Venous Access Devices (CVADs)

This document is NOT FOR PROMOTIONAL USE. Do not copy, distribute, or share with physicians, staff, or patients. FOR INTERNAL USE ONLY.

HCHS/SOL Follow-up Interview Form Contact Year 8

OECD Webinar on alternatives to long chain PFCs Co-organized with the Stockholm Convention Secretariat 18 April 2011

ManpowerGroup Employment Outlook Survey Global

NURSING POLICIES, PROCEDURES & PROTOCOLS

E-Seminar. Teleworking Internet E-fficiency E-Seminar

CENTRAL LINE ASSOCIATED BLOOD STREAM INFECTIONS (CLABSI)

Peripherally Inserted Central Catheter (PICC)

Generosity of R&D Tax Incentives

SARASOTA MEMORIAL HOSPITAL STANDARDS OF CARE STANDARDS OF PRACTICE DEPARTMENT OF IV THERAPY (IV THERAPISTS)

BE MOBILE! > L AUNCH BREAK < FROM 15 TH TO 30 TH NOVEMBER THE PROFESSORS PROMOTING PRESENT PARTNER SCHOOLS

1. The number of known arms producers has doubled after the end of the cold war.

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

Q Manpower. Employment Outlook Survey Global. A Manpower Research Report

Exploiting International Life Science Opportunities. Dafydd Davies

Skin Tunnelled Catheter (STC), also known as Central line

Organization: Sinai Hospital of Baltimore

Manpower Employment Outlook Survey

Implementation of the System of Health Accounts in OECD countries

Manpower Employment Outlook Survey Ireland. A Manpower Research Report

PATIENT CARE MANUAL PROCEDURE

Policies and Procedures. RNSP: RN Procedure. I.D. Number: 1067

SPONSORSHIP OPPORTUNITIES

Global Workforce Trends. Quarterly Market Report September 2017

A new option for you. What is the Primo Port?

Vascular Access Department Insertion of a peripherally inserted central catheter Information for patients

CENTRAL VENOUS LINES: REMOVAL

Quarterly Monitor of the Canadian ICT Sector Third Quarter Covering the period July 1 September 30

Administration of IV Medication in the Community by the Children s Community Nursing Team Standard Operating Procedure

WHY IMPLEMENT CENTRAL LINE INSERTION BUNDLES

Objectives. Vessel Health and Preservation: Disclosure. Ms. Moureau has disclosed the following: Angiodynamics, Genentech

Country Requirements for Employer Notification or Approval

Advancement Division

International Cooperation Types of Activities

INTERNATIONALISATION GRANTS FOR YOUNG GRADUATES

Options for Attracting Research Students to Australia

ManpowerGroup Employment Outlook Survey Global

ManpowerGroup Employment Outlook Survey Global

patientinformation Peripherally inserted central catheter (PICC) Vascular Access The Rotherham NHS Foundation Trust

Manpower Employment Outlook Survey

THE NATIONAL INVESTMENT IN RESEARCH. Professor Vicki Sara Chair, Australian Research Council

The G200 Youth Forum 2015 has 4 main platforms which will run in tandem with each other:

OECD Information Technology Outlook 2010 Highlights

WYOMING STATE BOARD OF NURSING ADVISORY OPINION

International Recruitment Solutions. Company profile >

BRIDGING GRANT PROGRAM GUIDELINES 2018

The EUREKA Initiative. Matteo Fedeli EUREKA Secretariat

ADMINISTRATION OF BLOOD PRODUCTS (RED CELLS, PLATELETS, PLASMA, & CRYOPRECIPITATE) NICU SYRINGE METHOD

Intravenous Injection of Contrast Media COMPETENCY PROFILE. Prepared by The Ontario Association of Medical Radiation Sciences

The EUREKA Initiative An Opportunity for Industrial Technology Cooperation between Europe and Japan

Assisting with the Bedside (Percutaneous) Removal of Chronic Peritoneal Dialysis Catheters

Heart Rhythm Program, St. Paul s Hospital Lead Extraction

Q4/13. Contents. Hong Kong Employment Outlook. Global Employment Outlook. About the Survey. About ManpowerGroup. Sector Comparisons

UPMC PASSAVANT Policy Manual. TITLE/SUBJECT: IntraOsseous Device POLICY NO:

Sage business index. Global trends. Executive summary. Sage Insights Smart thinking

Transcription:

ARROW PRESSURE INJECTABLE PICC Expect more from your PICC

EXPECT MORE FROM YOUR PICC DISTINCT LABELING pressure injection capabilities are marked on the extension line hubs with each lumen s maximum flow rate FLEXIBLE LOW PROFILE JUNCTION HUB designed for patient comfort and easy of maintenance The arrow Pressure Injectable PICC was developed for ease-of-use, smooth insertion and patient comfort. Arrow PICC is the choice for those who simply demand more from their PICC. The arrow Pressure Injectable PICC is a polyurethane open ended catheter, indicated for short or long-term peripheral access to the central venous system for intravenous therapy, blood sampling, central venous pressure monitoring, infusions and power injection of contrast media. PRESSURE INJECTION CAPABILITY The maximum pressure of power injector equipment used with the Pressure Injectable PICC may not exceed 300 psi while the maximum flow rate of infusion is 4 ml/sec (single and double lumens PICC) and 6ml/sec (triple lumens PICC). The arrow Polyurethane ensures high resistance while maintaining softness and gentleness once into the vessel. TAPERFREE CATHETER DESIGN same French size between distal tip and the hub, reduces the risk of thrombosis 2,3,4

CHOOSE THE RIGHT LENGTH, DO NOT TRIM THE TIP The arrow Pressure Injectable PICC is available in three different lengths (40, 0, cm) thus eliminating the need to trim the line and avoiding to alter the integrity of the catheter itself. This means saving all the benefits related to the Blue Flex Tip and the Staggered Exit Ports. BLUE FLEX TIP & STAGGERED EXIT PORTS The contoured design is softer than the rest of the catheter, which allows for smooth maneuvering through narrow, tortuous vessels with less trauma. With this unique tip design, multilumen PICC s have staggered ports. These ports are intended to reduce the risk of medications mixing and creating a precipitate that could potentially occlude the catheter 1. The Blue Flex Tip is also designed to track better over wire. Blunt, ragged tip on conventional trimmable catheter poses risk of intimal trauma BLUE FLEX TIP Unique to Arrow. Soft contoured tip design to enhance maneuverabilitywhile minimizing vessel trauma STAGGERED EXIT PORTS reduce the risk of mixing incompatible medications that can create precipitate 1 With the Blue Flex Tip, it is also the only PICC that can be inserted without a sheath in over-the-wire interventional insertions. It provides instant visual confirmation upon the removal. The soft, contoured tip is designed to be easier to maneuver and minimize trauma DOUBLE NUMBERING simplifies documentation of catheter length

SAME SIZE FROM TIP TO HUB Our attention to detail and focus on safety extends over the entire length of the catheter. arrow PICCs are taper-free as we strive to make procedures complication-free. The arrow TaperFree catheter design assures the clinician stated size is consistent between the distal and proximal ends. Long tapered catheter bodies can be up to two French sizes larger than what s actually labeled. This presents you with a catheter to vessel ratio that increases the risk of thrombosis 2,3,4. Fr Fr RISK OF THROMBOSISRISES AS FRENCH SIZE INCREASES 2 REVERSE FREE DESIGN RISK OF THROMBOSIS 10% 8% 6% 4% 2% 0% 1% 6.6% 4 Fr. Fr. 6 Fr. SIZE OF CATHETER 9.8% According to a study published in the Journal of Vascular and Interventional Radiology, the risk of thrombosis rises as French size increases 3 (see chart). To minimize this risk, the authors recommend using the smallest acceptable catheter required for the therapy. With a tapered catheter body there can be a considerable difference between the French size at the tip and the French size at the proximal end. This type of design puts the widest portion of the catheter into the narrowest portion of the vein. For the sake of their patients, clinicians need to know that the French size of their PICC does not vary. With Arrow PICCs you can depend on it. In fact, a study evaluating outcomes associated with a 6 French reverse tapered triple lumen PICC, was stopped prematurely due to unacceptably high venous thrombosis rate 4. 1 Collins JL, Lutz RJ. In Vitro Study of Simultaneous Infusion of Incompatible Drugs in Multilumen Catheter. Heart & Lungs. 1991; 20(3):271-7 2 Nifong, T., McDevitt, T. The Effect on Catheter to Vein Ratio on Blood Flow Rates in a Sumulated Model of Peripherally Inserted Central Venous. Chest 2011;140;48-3 3 Grove JR, Pevec WC. Venous Thrombosis Related to Peripherally Inserted Central Catheters. Journal of Vascular and Interventional Radiology. 2000; 11: 837-840. 4 Trerotola, S., Stravropoulos, S., Mondeschein, J., Patel, A., Fishman, N., Fuchs, B., Kolansky, D., Kasner, S., Pryor, J., Chittams, J. Triple-Lumen Peripherally Inserted Central Catheter in Patients in the Critical Care Unit: Prospective Evaluation. Radiology. 2010; 26 (1.2).) Data on file

PRODUCT & ORDERING INFORMATION PRESSURE INJECTABLE PICC Lumen Ref. Kit Configuration 1 EU-24041-HPMSB outer ø (Fr) Inner Ø* (Gauge) LengtH (Cm) Max Flow Rate* (ml/sec) Flow Rate* (ml/hr) EU-24041-HP Basic Nursing 4 18 40 4 1020 EU-24041-IR Interventional Radiology EU-2041-HPMSB qty 1 EU-2041-HP Basic Nursing 4 18 0 4 720 EU-2041-IR Interventional Radiology EU-241-HPMSB 1 EU-241-HP Basic Nursing 4 18 4 660 EU-241-IR Interventional Radiology 2 EU-2402-HPMSB EU-2402-HP Basic Nursing 18/18 40 4/4 630/720 EU-2402-IR Interventional Radiology EU-202-HPMSB 2 EU-202-HP Basic Nursing 18/18 0 4/4 40/600 EU-202-IR Interventional Radiology 2 EU-22-HPMSB EU-22-HP Basic Nursing 18/18 4/4 480/40 EU-22-IR Interventional Radiology 3 EU-24063-HPMSB 6 17/19/19 40 6/NoCT/NoCT 160/0/0 EU-24063-HP Basic Nursing 3 EU-2063-HPMSB 6 17/19/19 0 6/NoCT/NoCT 1320/480/40 EU-2063-HP Basic Nursing 3 EU-263-HPMSB 6 17/19/19 6/NoCT/NoCT 1070/390/360 EU-263-HP Basic Nursing *Distal/Proximal/Medial KIT COMPONENTS Kit configuration Arrow Pressure Injectable PICC GlideThru Microintroducer Echogenic Introducer Needle 21Gax7Cm 0.018 in x 4 Cm Nitinol Guidewire 0.018 in x 130 Cm Stainless Steel Guidewire Scalpel, Safety 2 Ga Hypodermic Needle, Safety 22Ga Hypodermic Needle, Safety 10 ml Syringe 3 ml Syringe Filter Needle Sharps Away Locking Disposal Cup Catheter trimmer, Safety Needle Free Connectors Full Body drape Fenestrated drape Surgical gown Mask Mask with Eyeshield Cap Absorbent Towel Towel Hemo-Hopper Fluid Receptacle Sutureless Fixation Device Transparent Dressing Tourniquet Tape Measuring tape Gauze Pad cmxcm Gauze Pad 10 cm x 10 cm Ultrasound Sterile Probe Cover Maximal Barrier Nursing Kit Basic Nursing Kit Interventional Radiology Kit

Teleflex is a leading global provider of specialty medical devices used for diagnostic and therapeutic procedures in critical care, urology and surgery. Our mission is to provide solutions that enable healthcare providers to improve outcomes and enhance patient and provider safety. We specialise in devices for general and regional anaesthesia, cardiac care, respiratory care, urology, vascular access and surgery and we serve healthcare providers in more than 10 countries. Teleflex also provides specialty products for medical device manufacturers. Our well known brands include arrow, deknatel, gibeck, hudson rci, KMedic, lma, Pilling, Pleur-evac, rüsch, sheridan, taut, tfx oem, vasonova, vidacare and weck, all of which are trademarks or registered trademarks (in the U.S. and/or other countries) of Teleflex Incorporated. Teleflex global operations: Australia, Austria, Belgium, Canada, China, Czech Republic, France, Germany, Greece, India, Ireland, Italy, Japan, Korea, Malaysia, Mexico, Netherlands, New Zealand, Portugal, Singapore, Slovak Republic, South Africa, Spain, Switzerland, United Kingdom, Uruguay and USA. YOUR INTERNATIONAL CONTACTS: TELEFLEX HEADQUARTERS INTERNATIONAL, IRELAND Teleflex Medical Europe Ltd., IDA Business and Technology Park, Dublin Road, Athlone, Co Westmeath Phone +33 (0)9 06 46 08 00 Fax +33 (0)14 37 07 73 orders.intl@teleflex.com AUSTRALIA/NEW ZEALAND 1300 360 226 AUSTRIA +43 (0)1 402 47 72 BELGIUM +32 (0)2 333 24 60 CHINA (SHANGHAI) +86 (0)21 6163 096 CHINA (BEIJING) +86 (0)10 6418 699 CZECH REPUBLIC +420 (0)49 79 111 FRANCE +33 (0) 62 18 79 40 GERMANY +49 (0)711 406 0 GREECE +30 210 67 77 717 INDIA +91 (0)44-2836 040 ITALY +39 0362 8 911 JAPAN +81 (0)3 3379 111 KOREA +82 2 36 70 NETHERLANDS +31 (0)88 00 21 00 PORTUGAL +31 22 41 90 8 SINGAPORE +6 6439 3000 SLOVAK REPUBLIC +421 (0)3377 24 28 SOUTH AFRICA +27 (0)11 807 4887 SPAIN +34 918 300 41 SWITZERLAND +41 (0)31 818 40 90 UNITED KINGDOM +44 (0)1494 3 27 61 For detailed information see www.teleflex.com Teleflex is a registered trademark of Teleflex Incorporated or its affiliates. The products in this catalogue may not be available in all countries. Please contact your local representative. All data current at time of printing (11/201). Subject to technical changes without further notice. 201 Teleflex Incorporated. All rights reserved. 94 11 10-00 00 01 REV A MC / PDF 11 1 PDF