The Joint Commission Medication Compounding Certification (MDC) FAQs

Similar documents
USP <797> PERSONAL HYGEINE PERSONAL PROTECTION EQUIPMENT

6/23/2011. Compounded Sterile Products Update and Review. Learning Goals for the Pharmacist. Learning Goals for the Pharmacy Technician

Sterile Compounding of Hazardous Drugs

Compounded Sterile Preparations Pharmacy Content Outline May 2018

Pharmacy Sterile Compounding Areas

The Leader in Guidance for the Health Information Management Profession. Patient Safety Monitor Journal

Introduction to USP General Chapter <800> How Will It Affect Federal Pharmacy?

Advanced Sterile Product Preparation Training and Certificate Program

1.0 Sterile Compounding Personnel

Implementing USP

Implementing USP 800 ASHLEY DUTY, PHARMD, MS JOANNA ROBINSON, PHARMD, MS

Implementing USP 800 ASHLEY DUTY, PHARMD, MS JOANNA ROBINSON, PHARMD, MS

USP 797: A FOCUS ON ANTIMICROBIAL RISK LEVEL KAREN MILKIEWICZ, PHARMD

Pharmacy General Personnel

PHARMACY SERVICES / MEDICATION USE

To provide information about the role of the pharmacy in Infection Prevention and Control.

Preventing Occupational Exposure to Hazardous Drugs

CHAPTER 2 GENERAL PRACTICE OF PHARMACY REGULATIONS. These regulations are promulgated as authorized by the Act.

CASE STUDY: PENINSULA REGIONAL MEDICAL CENTER

Understanding USP 797

ONCOLOGY PRACTICE MANAGEMENT

STATE OF FLORIDA DEPARTMENT OF HEALTH

USP <800>: Navigating the New Requirements for Handling Hazardous Drugs in the Community Oncology Setting

STATE OF FLORIDA DEPARTMENT OF HEALTH

Of Critical Importance: Infection Prevention Strategies for Environmental Management of the CSSD. Study Points

CHAPTER 17 STERILE PRODUCT COMPOUNDING 17-1

SCOPE PURPOSE. BACKGROUND and DEFINITIONS

Intravenous Admixture Program. Effective Date: 3/4/95. Revised: 04/08, 7/11, 7/14. Page 1 of 17. Purpose:

Meeting New Requirements for Sterile Compounding Webinar

Personal Hygiene & Protective Equipment. NEO111 M. Jorgenson, RN BSN

RULES OF THE TENNESSEE BOARD OF PHARMACY CHAPTER STERILE PRODUCT PREPARATION IN PHARMACY PRACTICE TABLE OF CONTENTS

The Home Infusion Compounder's Guide to the Second Proposed Revision to USP <797>

This course was written for RN.ORG by an outside consultant and RN.ORG has rights for distribution but is not responsible for the contents.

The Joint Commission

11/4/2016. Sterile Compounding: USP<797> Revisions and the Compounding Quality Act. In the 1930 s and 40 s, 60% of all medications were compounded.

KPIC Aseptic Technique Training Program

KPIC Aseptic Technique Training Program Friday, August 24 th Saturday, August 25 th, 2018

Leveraging Nursing Expertise with USP<800>

Department Policy. Code: D: MM Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

PERSONAL PROTECTIVE EQUIPMENT (PPE) Standard Operating Guidance

CHEMOTHERAPY/HAZARDOUS DRUGS PRECAUTIONS, PREPARATION, ORDERING

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157

2017 Pharmacy Education Series

2012 Academy Seminar - Thessaloniki, Greece DOs and DON Ts in setting up a new facility. 21 April 2012, Barbara Wimmer,

PC EP 4; PC EP 7. (Outpatient Only) If nutritional screen positive, plans for follow-up documented.

USP <797>: Making the Case for Increasing Environmental Controls in Pharmaceutical Compounding. By Eric S. Kastango, M.B.A., R.Ph.

Oregon Health & Science University Department of Surgery Standard Precautions Policy

ASHP Guidelines on Compounding Sterile Preparations

SARASOTA MEMORIAL HOSPITAL

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

Compounding Conundrums: Outsourcing Shortages, Clean Room Design, and Hazardous Drugs 2012 Midyear Clinical Meeting

Infection Prevention Implementation and adherence to infection prevention practices are the keys to preventing the transmission of infectious diseases

DoD Space Planning Criteria for Health Facilities Pharmacy (Chapter 5.5)5.5.1 PURPOSE AND SCOPE

USP <800> and What Changes Will Mean for Oncology Practices November 2, 2016 State Society Education Series

42 CFR Infection Control

Infection Prevention and Control in the Dialysis Facility

Clinical IQ, LLC September 2, 2009

Infection Prevention and Control and Isolation Authored by: Infection Prevention and Control Department

RE: MHA and MSHP and Joint Comments Proposed 247 CMR Sterile Compounding Regulations

NORTH DAKOTA STATE BOARD OF PHARMACY PRACTICE ACT PAGE #

2018 Pharmacy Education Series

Ensuring Readiness for USP Chapter <800> on Handling Hazardous Drugs: Assessment, Planning, and Implementation

OR staffing supports the provision of safe perioperative patient care and promotes a safe perioperative environment

4/18/2018. Improving USP <800> Compliance in a Community Healthcare Organization. Disclosures. Learning Objectives

Check List Putting On (Donning) PPE Removing (Doffing) PPE. Sources: Victorian Ebola Virus Disease Plan Version 2: 12 November 2014.

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Student Protocol for the Operating Room. Vangie Dennis, RN, CNOR, CMLSO

Ebola Isolation Precaution Checklist Donning PPE

Training Your Caregiver: Hand Hygiene

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

Hazardous Medication Personal Protective Equipment (PPE) Guide and List

HAI Outbreak Response: A Tabletop Exercise

OPERATING ROOM ORIENTATION

Root Cause Analysis. Why should you dig deeper? Joe Cabaleiro, R.Ph. Gates Healthcare Associates LP3 Network Inc. MEDISCA Network Inc.

Elements of dialysis care that may promote the spread. Applying lessons from the patient safety movement to

Newfoundland and Labrador Pharmacy Board Standards of Practice

Infection Control: You are the Expert

Checklist for Office Infection Prevention and Control

PPE During the Management of Ebola

Department of Public Health Infection Control Survey

MODEL STANDARDS FOR PHARMACY COMPOUNDING OF NON-HAZARDOUS STERILE PREPARATIONS

June 2018 Phc newsletter

TOP 10 ASC COMPLIANCE FAQs

Operational Impacts of Adhering to NIOSH and USP 800 Standards

Risk Assessment for the TB Laboratory

HAZARDOUS DRUGS: HANDLING PRECAUTIONS BACKGROUND PURPOSE POLICY STATEMENTS

Access to the laboratory is restricted when work is being conducted; and

While Your Child Is on the BMT Unit

Infection Control Prevention Strategies. For Clinical Personnel

Student Protocol for the Operating Room. Authored by: Vangie Dennis, RN, BSN, CNOR, CMLSO

About OMICS Group Conferences

USP <797> does not apply to the administration of medications.

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

Hospital Construction, Renovation, and Demolition

Jeanne Moldenhauer (c) Jeanne Moldenhauer

Continuing Care Health Service Standards Standard 11.0 Audit Readiness Checklist (ARC)

Pulmonary Care Services

Burn Intensive Care Unit

Step 1A: Before entering patient room, be sure you have all the material ready and available:

PRESENTORS Cyndi McCullough Andrew Yosten

Transcription:

The Joint Commission will be implementing the new Medication Compounding Certification (MDC) program for hospitals, critical access hospitals, and home care pharmacy organizations in the state of Michigan on 1/9/17. This Certification will assess organizations compliance with Joint Commission standards based on the USP Chapter <797> requirements on sterile compounding. The Joint Commission has received a number of questions about the standards in this new program and this FAQ document was developed to address them: Number Question Answer Comment 1 What is the definition of compounding? The MDC Certification glossary contains a definition of compounding. The glossary, along with other helpful MDC documents, can be found at this link: 2 Is there a non-pdf version of the MDC Certification standards? 3 Is it sufficient to use an SOP and attach it to the management operating directive (a type of policy specific to the organization) to use as a policy? The organization is unable to update an entire policy and have it approved by 1/17. 4 In the proposed update to USP Chapter <797>, the requirement for garbing is cleanest to dirtiest. The current USP Chapter <797> requirements for garbing is dirtiest to cleanest. Which will you be looking for to be in compliance? https://www.jointcommission.org/certification/ medication_compounding.aspx No, the only version available to organizations is in pdf format. Yes, for the initial Certification review, this will be acceptable. The proposed USP Chapter <797> changes have not been finalized or approved. The reviewers will be reviewing organizations using the MDC Certification standards, which are based on the current USP Chapter <797> requirements which state garbing is dirtiest to cleanest. The Joint Commission 1 12/30/16

5 Can an ante room be ISO Class 8 or if there is negative pressure, can it be ISO Class 7? 6 Does the buffer room have to be ISO Class 7? If it is ISO Class 5, is it okay if you re-alcohol? 7 In the organization, the ER has a compounding area (unclassified) with an ISO Class 5 laminar flow hood. What is considered a good segregated compounding area? Does this room need to be a physically separated area, or is a room with an area demarcated acceptable? 8 The new expanded list of hazardous medications contains many which are compounded for immediate use. Will reviewers only be looking at antineoplastics or will they look at other hazardous drugs for immediate use? 9 Several standards about the physical environment (such as MDCSN.3, MDCN.3, MDCS.1) often refer to USP Chapter <797>. Based on the definition in USP Chapter <797>, the Ante Room should be ISO Class 8 or better. Based on the guidance in USP Chapter <797>, the buffer room must be ISO Class 7 or better. If the buffer room is ISO Class 5, once items are entered into the direct compounding area, staff must re-alcohol these items (USP Chapter <797>, suggested SOPs 17, 18, 19). Joint Commission engineers do not answer specific pharmacy infrastructure and design questions (or review infrastructure designs) prior to construction. The organization should refer to USP Chapter <797> requirements when planning for construction or changes to their compounding pharmacy. Any hospital or home care organization engaging with a consultant and/or contractor to construct these types of areas should consider whether or not the person engaged and overseeing the process has working knowledge of USP requirements. Another resource that may be of help are the Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014, at Sections 2.1-4.2 entitles Pharmacy Services. Reviewers will very likely look at antineoplastics, but they may also look at other hazardous medications that are being compounded. See the new NIOSH list of hazardous medications: https://www.cdc.gov/niosh/topics/antineoplasti c/pdf/hazardous-drugs-list_2016-161.pdf The USP Chapter <800> requirements do not go into effect until July 1, 2018. The surveyors will be surveying to the MDC Certification standards, which are based on the current USP Chapter <797> requirements. The Joint Commission 2 12/30/16

With the pending changes that will occur with USP Chapter <800>, is there an engineering matrix or flow chart for everything including ACPH, pressure relationships, temperature and humidity, and monitoring of these? 10 If we are going to do construction (including the clean room, chemo room, etc.), what is the allowable time frame that this will need to be completed to obtain certification? 11 If the organization does not have funding to start and complete the construction within the 3-6 month period, is there a waiver that can be requested until funding is available? 12 The ACPH (exchange and fresh air) requirements for hazardous compounding were mentioned as going away when USP Chapter <800> goes into effect. Is this true? What are the requirements that we should be following? When the Certification report is completed and submitted, the organization has 60 days to submit their Evidence of Standards Compliance (ESC) report. The organization will have from 3-6 months to complete any construction needed to meet the standards. If the construction necessary will require a longer timeframe, it will be reviewed by the Standards Interpretation Group and engineers when the 60-day ESC and their plan are submitted. No, at this time there is no waiver or extension process that allows for a delay in construction until funds are available. The USP Chapter <800> requirements do not go into effect until July 1, 2018. The reviewers will be using the MDC Certification standards for the onsite review, which are based on the current USP Chapter <797> requirements. The Joint Commission 3 12/30/16

13 What HEPA filtration is required for meeting the current and USP Chapter <800> requirements? 14 Do you have a schematic outlining pressure differentials for USP Chapter <797> vs USP Chapter <800>? 15 For low and medium risk compounding, media fill and fingertip testing is a requirement in USP Chapter <797>, but it does not address immediate use needs (for nurses). Work is being done in a laminar flow hood, not on a table top. Do these nurses need to be in full PPE during the immediate use compounding? 16 Can people wear hospital scrubs over their own garments in the clean room? We have many employees who wear head scarves and long sleeved garments for religious reasons. It is not recommended to wear garments from outside in the clean room. 17 What is the definition of compounding Current USP Chapter <797> requirements related to HEPA filtration can be found in sections: IX. Hazardous Drugs as CSPs, and XIII.C. Facility Design and Environmental Controls MDC Certification standards with HEPA filtration include: MDCSN.03, EP11 and MDCS.08, EP5. No, we do not have this. Please refer to USP Chapter <797>; USP Chapter <800> is not yet in effect, so you will not be reviewed to USP Chapter <800>. Media fill and fingertip testing is not required for nurses doing immediate use compounding. Use didactic and observational methods to assess nursing competency. Note: For the initial reviews in MI, reviewers will not visit nursing units to observe nurses performing compounding for immediate use. Reviewers will only visit the main pharmacy and satellite pharmacies. Nurses are to use aseptic technique, and wear sterile gloves. Per USP Chapter <797>, Appendix 1, "compounding personnel shall remove personal outer garments; cosmetics; artificial nails; hand, wrist, and body jewelry that can interfere with the fit of gowns and gloves; and visible body piercing above the neck." These should all be removed prior to putting on scrubs to wear in the clean room. The MDC Certification review will only observe medication compounding in the Surgery The Joint Commission 4 12/30/16

medications in the OR suites? Do all medications given in the OR need to be mixed by a pharmacist? 18 We are building a new clean room in one of the OR pharmacies and have several construction questions concerning materials used for the walls, counter tops, flooring, paint, lighting, and doors. We also have questions about the number and type of required air exchanges in the buffer room and clean room. 19 What products are acceptable to be used to wipe down items brought into the clean side of the anteroom? Also, what products can be used to wipe down the clean room hoods and chemo hoods? 20 Unlike most pharmacies, our pharmacists do the compounding. Our pharmacy technicians are only responsible for attaching the vial department if there is a satellite pharmacy with a compounding pharmacist located in the Surgery department. Compounding in the OR suites will not be observed in the initial reviews in MI. These questions all relate to your organization s pharmacy infrastructure and new construction. You need to consult the USP Chapter <797> requirements for these items, and work with your engineers to ensure that the work is done properly. For example, the countertops need to be installed in a manner that prevents the risk of bacterial or infectious process proliferation, and they must be able to withstand the rigorous cleaning required. Joint Commission engineers do not review clean room design plans (or any other infrastructure designs) prior to construction. Any hospital engaging with a consultant and/or contractor to construct the area should consider whether or not the person engaged and overseeing the process has working knowledge of USP Chapter <797> requirements. Another resource that may be of help are the Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014, at Sections 2.1-4.2 entitled Pharmacy Services. The Joint Commission does not provide guidance regarding specific products that are acceptable for proper cleaning. The organization needs to investigate various products to determine which meet the USP Chapter <797> requirements and the needs of the organization. The coupling of MINI-BAG Plus and VIAL- MATE are not considered compounding per USP Chapter <797> and therefore these pharmacy technicians would not be required to complete the training elements required for a compounding employee if they are not compounding. The Joint Commission 5 12/30/16

using the MINI-BAG Plus System and the VIAL-MATE Adaptor Device. Are the technicians required to do Media fill and gloved fingertip testing? Can this function be done outside the clean room by the technicians? 21 During the overview, it was mentioned you have to use a new alcohol wipe for each entry point. If we are compounding 1200mg Remicade, for example, we could potentially use 30 alcohol wipes. We wanted to confirm that this is what is expected. 22 Our organization is beginning a renovation to install a hazardous negative pressure room and a positive pressure clean room connected by an anteroom. We need to confirm the type of hood that needs to be installed to meet USP Chapter <800> requirements (Class Caution should be made to ensure that these items are being coupled in the ISO Class area required by the manufacturer. If this does involve utilization of the ISO Class 5 or Class 7 buffer areas, then it would be prudent to ensure they have training on that environment and appropriate restrictions to ensure the integrity of that area. Yes, USP Chapter <797> requires that the alcohol swab used to clean a critical point on a vial does not touch any other item prior to its use. Here is the text from USP Chapter <797>: Cleaning and Disinfecting the Compounding Area Wiping with small sterile 70% IPA swabs that are commercially available in individual foil-sealed packages (or a comparable method) is preferred for disinfecting entry points on bags and vials, allowing the IPA to dry before piercing stoppers with sterile needles and breaking necks of ampuls. The surface of the sterile 70% IPA swabs used for disinfecting entry points of sterile packages and devices shall not contact any other object before contacting the surface of the entry point. Sterile 70% IPA wetted gauze pads or other particle-generating material shall not be used to disinfect the sterile entry points of packages and devices. (Note: This was confirmed with USP leadership on 12/20/16.) USP Chapter <800> is not finalized and advice cannot be given to those expectations (this does not go into effect until July 1, 2018). The organization is encouraged to review the information currently available (USP Chapters <797> and <795>) and make decisions based on their review. Joint Commission engineers do not review infrastructure and design plans (or any other infrastructure designs) prior to construction. Any hospital or home care organization engaging with a consultant and/or contractor to construct these types of areas should consider whether or The Joint Commission 6 12/30/16

II Type A2 or B2). Is it possible for us to send our clean room design plans to Joint Commission engineers for review prior to beginning the project? 23 With USP Chapter <800>, the oncology meds need to be stored in the negative pressure room. It was mentioned in the overview that the chemo vials have to be removed from the non-corrugated cardboard boxes before going into the room. We would like to confirm this. We do see some problems if we need to return the medications to the wholesaler. With the cost of these medications, we do send medications back if a patient s treatment changes and won t be needed the product. 24 Are the use of closed system transfer devices a current requirement when compounding hazardous drugs in a Class II Type A2 cabinet in a nonnegative pressure room? Will there be a requirement for compounding in a not the person engaged and overseeing the process has working knowledge of USP requirements. Another resource that may be of help are the Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014, at Sections 2.1-4.2 entitles Pharmacy Services. USP Chapter <800> does not go into effect until July 2018. Guidance regarding USP Chapter <800> cannot be provided at this time. Organizations will not be reviewed for compliance with USP Chapter <800>. Yes, closed system transfer devices are required when compounding hazardous drugs in a Class II Type A2 cabinet in a non-negative pressure room. If the organization does a low volume of compounding of hazardous medications it would be acceptable for the organization to use a CSTD in a non-negative pressure room based on USP Chapter <797>. Optimally, all hazardous medications should be compounded in a hood that is 100% vented to the outside. The Joint Commission 7 12/30/16

negative pressure room? 25 Can you explain the master formulary record requirement? 26 At the MI training, someone mentioned that we need to have a signed Hazardous Drug Risk Acknowledgement for every employee who has reproductive capability. My HR department is pushing back on this a little. Is there someone there that can point me to where this requirement is within the standards or USP chapter? 27 We are planning on making renovations to our compounding space. We may not be able to begin construction until mid-february and are uncertain about our completion date. We are considering using the glove box until our renovations are completed. Is this a viable option for us? Do you know if the utilization of a glove box (CACI) will meet This requirement is for nonsterile compounding, and is based on USP Chapter <795> at: XI. Compounding Documentation. Because we are not reviewing nonsterile compounding for the MI organizations on the first reviews, it does not apply to the initial reviews. For your information, it is addressed at MDCN.07, EP5. This is the requirement that addresses the Hazardous Drug Risk Acknowledgement: MDCSN.04, EP6 The organization advises all compounding staff of the risks to their reproductive systems when handling hazardous medications and confirms in writing that staff understand these risks. It is covered in USP Chapter <797> at: IX. Hazardous Medications as CSPs As long as the glove box (CACI) is in a segregated compounding area, it is a viable option until your construction is completed. Keep in mind that garbing is required just as if using a laminar flow hood in a clean room or a bench in a clean room. For example, hand cleaning, gowns, masks, gloves, etc. and protocol for changing both large gloves and the small sterile gloves per policy and manufacturer's guidelines must be followed. Also, the same compounding staff competencies are required for staff utilizing the glove box. Note: The above is just one suggestion of a way to comply with the standards, but it is not the only way. If the above criteria are met and the organization is in compliance with sterile compounding The Joint Commission 8 12/30/16

the MDC Standards throughout 2017? 28 Our question pertains to the physical requirements of an IV cleanroom/ante room. The current layout is a single room containing both "ante" room and "clean" room designated areas. Additionally, the room air quality is consistently maintaining an ISO Class 7 environment. We are also in the process of building a new facility, so I need to determine how much renovation needs to occur in our existing facility which we are expected to vacate in 2018. standards at the time of the review, utilization of the glove box is acceptable. This question is specific to your renovation and construction to upgrade your compounding areas. Joint Commission engineers do not answer specific pharmacy infrastructure and design questions (or review infrastructure designs) prior to construction. The organization should refer to USP Chapter <797> requirements when planning for construction or changes to their compounding pharmacy. You can choose to work with your organization s engineers or a consultant and/or contractor. Any hospital or home care organization engaging with a consultant and/or contractor to construct these types of areas should consider whether or not the person engaged and overseeing the process has working knowledge of USP requirements. Another resource that may be of help are the Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014, at Sections 2.1-4.2 entitled Pharmacy Services. The Joint Commission 9 12/30/16