Clinical staff undertaking Endoscopy and Nasendoscope interventions

Similar documents
Decontamination of Medical and Laboratory Equipment Prior to Maintenance or Transportation

The Newcastle upon Tyne Hospitals NHS Foundation Trust. Decontamination of Healthcare Equipment following Patient Use and Prior to Service or Repair

NHS GREATER GLASGOW & CLYDE CONTROL OF INFECTION COMMITTEE POLICY

HANDLING OF LAUNDRY POLICY

Decontamination of equipment

Reprocessing of Flexible Endoscopic Instruments

Shetland NHS Board Standard Operating Procedure for Cleaning, Maintenance, Audit and Replacement of Mattresses

THE DECONTAMINATION OF SURGICAL INSTRUMENTS AND OTHER MEDICAL DEVICES

Decontamination of Medical Devices:

Unannounced Theatre Inspection Report

Australian/New Zealand Standard

Infection prevention and control in your practice

DIAGNOSTIC CLINICAL TESTS AND SCREENING PROCEDURES MANAGEMENT POLICY

AS/NZS 4187:2003 AS/NZS

abcdefghijklm abcde abc a From the Chief Medical Officer eé~äíü=aéé~êíãéåí= Dear Colleague

Infection Control in General Practice

Infection Control Safety Guidance Document

INFECTION PREVENTION & CONTROL, INCLUDING PROCESSING ITEMS FOR REUSE, IN GENERAL PRACTICE

Device Ultrasound transducer probes with an internal lumen used for taking transrectal prostate biopsies.

First Aid Policy. Appletree Treatment Centre

Sharps Management Protocol Infection Prevention and Control Procedure

TOP 10 ASC COMPLIANCE FAQs

Step 1A: Before entering patient room, be sure you have all the material ready and available:

Guidance for registered pharmacies preparing unlicensed medicines

Patient held instrumentation Clinical Guideline

Comply with infection control policies and procedures in health work

Infection Control Policy

Sterile Supply Techniques. Level 5 L Module Descriptor

Pre-surgical assessment for variant Creutzfeldt-Jakob Disease (vcjd) risk in neurosurgery and eye surgery units

Section F - Decontamination Policy

Best Practice Guidelines BPG 5 Catheter Care

Linen Services Policy

NSQHS Standard 3: How are we going?

Standard Precautions for Infection Control

Pulmonary Care Services

Version: 5 Date Issued: 24 October 2017 Review Date: 24 October 2020 Document Type: Policy. Sharps Safety Policy Quick Reference Guide

1.2 billion ambulatory care visits in US: physician offices, outpatient hospital and ED

Sharps Safety Policy

OR staffing supports the provision of safe perioperative patient care and promotes a safe perioperative environment

Standard 1: Governance for Safety and Quality in Health Service Organisations

CREUTZFELDT- JAKOB DISEASE (CJD) AND VARIANT CREUTZFELDT- JAKOB DISEASE (VCJD) POLICY

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

Cleaning policy. Document author Assured by Review cycle. 1. Introduction Purpose or aim Scope Definitions...

Burn Intensive Care Unit

Infection Prevention and Control (IPC) Standard Operating Procedure for LICE (PEDICULOSIS AND PHTHIRIASIS) in a healthcare setting

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

Ambulatory Surgical Center (ASC) INFECTION CONTROL SURVEYOR WORKSHEET

Regulations that Govern the Disposal of Medical Waste

ASBESTOS POLICY. Version: 3 Senior Managers Operational Group Date ratified: March 2016

The Safe Use of Sharps in Healthcare Guidance for managers and staff

WELSH HEALTH CIRCULAR

INFECTION C ONTROL CONTROL CONTROL EDUCATION PROGRAM

Control of Substances Hazardous to Health (COSHH) Procedure

Community Infection Prevention and Control Guidance for Health and Social Care. Waste Management

FIRST AID POLICY. (to be read in conjunction with Administration of Medicines Policy) CONTENTS

Infection Prevention and Control Guidelines: Spillage Management

Healthcare Associated Infection (HAI) inspection tool

Section G - Aseptic Technique. Version 5

: Hand. Hygiene Policy NAME. Author: Policy and procedure. Version: V 1.0. Date created: 11/15. Date for revision: 11/18

Clean and store care equipment to minimise the risks of spreading infection

Respiratory Protection Program

Developed in response to: Best Practice Health and Social Act 2008 CQC Fundamental Standards: 12

INFECTION CONTROL SURVEYOR WORKSHEET

DISINFECTION POLICY. Date of Issue March Date of Review March Version No. 1.0

Version: 2. Date adopted: 17 May publication: Review date: September Expiry date: March 2019

Unit title: Health Sector: Working Safely (National 4)

ANTT. What is it and do you need to know? Grampians Region Infection Control Group Sue Atkins Regional Infection Control Consultant

08/09/ elements required for Infection to occur. Chain of Infection. Evolution of Standard & Transmission Based Precautions

Spillage of Blood and Other Body Fluids

ASEPTIC & CLEAN (NON TOUCH TECHNIQUE) POLICY

Infection Prevention and Control and Isolation Authored by: Infection Prevention and Control Department

NHS Professionals. POL6 Infection Control Policy

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

No. 7 Dealing with Spills of Blood and Body Fluids

9/14/2017. Best Practices in Instrument Cleaning. Objectives. Healthcare-associated Infections

EXPOSURE CONTROL PLAN

Isolation Care of Patients in Isolation due to Infection or Disease

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

SFHEND21 - SQA Code HD22 04 Reprocess endoscopy equipment

Kevin Chapman Tissue Viability - Modern Matron

The Newcastle Upon Tyne Hospitals NHS Foundation Trust. Standard Precautions Policy

INFECTION CONTROL SURVEILLANCE POLICY

HANDLING AND DELIVERY OF LABORATORY SPECIMENS POLICY

STANDARD OPERATING PROCEDURE (SOP) TERMINAL CLEAN OF ISOLATION ROOMS

SOMERSET PARTNERSHIP NHS FOUNDATION TRUST REVISED WARD ESTABLISHMENTS TO SUPPORT THE RETURN TO CORE COMMUNITY HOSPITAL BEDS

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control

Hygiene Policy. Arrangements for Review:

Pharmacy Sterile Compounding Areas

BLOOD AND BODILY FLUID GUIDELINES

Policy for the Control and Management of patients Colonised or Infected with Vancomycin resistant enterococci (VRE)

MEDICAL WASTE MANAGEMENT PLAN

NHS GREATER GLASGOW & CLYDE STANDARD OPERATING PROCEDURE (SOP)

North East Ambulance Service NHS Trust Infection Prevention and Control Annual Work Plan April 2009 March 2010 October review (2)

Occupational safety in laboratories

Standard Operating Procedure (SOP) Neonatal Service Using the Sluice on the Neonatal Intensive Care Unit at the City Campus.

Responsible officer Tony Gray

ADMINISTRATIVE POLICY AND PROCEDURE MANUAL

Guideline for the Management of Patients with Known or Suspected Diarrhoea / Viral Gastroenteritis

Cleaning and Decontamination of the Environment and Patient Equipment Procedures (IPC Policy Manual)

Infection Control and Prevention On-site Review Tool Hospitals

Transcription:

DECONTAMINATION OF NON LUMENED ENDOSCOPIC EQUIPMENT ( INCLUDING CYSTOSCOPES AND NASENDOSCOPES) Version: 3 Date issued: December 2017 Review date: December 2020 Applies to: Clinical staff undertaking Endoscopy and Nasendoscope interventions This document is available in other formats, including easy read summary versions and other languages upon request. Should you require this please contact the Equality and Diversity Lead on 01278 432000 V3-1 - December 2017

DOCUMENT CONTROL Reference KA/Oct14/DFEEP Version 3 Status Final Author Head of IPC / Decontamination Lead Amendments 1.5 Amended following change of Decontamination responsibilities post move to new Bridgwater Community Hospital location October 2017; Policy updated to reflect changes in Endoscopy service provision (Bridgwater and Minehead Community Hospitals). Document objectives: To ensure that the Trust is able to provide assurance of compliance with robust Endoscope/Nasendoscope decontamination methodology, thus ensuring patient safety. Approving body Clinical Governance Group Date: November 2017 Equality Impact Assessment Impact Part 1 Date: December 2017 Ratification Body Senior Management Team Date: December 2017 Date of issue December 2017 Review date December 2020 Contact for review Lead Director Head of IPC/Decontamination Lead Director of Infection Prevention and Control CONTRIBUTION LIST Key individuals involved in developing the document Designation or Group Infection Prevention and Control Team Infection Prevention and Control Assurance Group Theatre and Endoscopy User Group Endoscopy Lead Nurse: BCH OPD Theatre Sister, Minehead Community Hospital Clinical Policy Review Group Clinical Governance Group Senior Management Team V3-2 - December 2017

CONTENTS Section Summary of Section Page Doc Document Control 2 Cont Contents 3 1 Introduction 4 2 Purpose & Scope 4 3 Duties and Responsibilities 4 4 Definitions 5 5 Flexible Endoscopy Service 5 6 Decontamination Principles 6 7 Local Monitoring 7 8 Training Requirements 7 9 Monitoring Compliance and Effectiveness 7 10 References, Acknowledgements and Associated documents 7 APPENDIX 1 STANDARD OPERATING PROCEDURE General Decontamination Principles for Endoscopes and Nasendoscopes 9 V3-3 - December 2017

1. INTRODUCTION 1.1 Flexible endoscopes are complex re-usable instruments that require unique consideration with respect to decontamination and must be decontaminated following every endoscopic procedure. 1.2 Staff responsible for flexible endoscope decontamination must be trained for the role and records of training and competency assessment retained. 1.3 There must be documented safe working practices for decontamination and periodic testing must be carried out as detailed in Choice Framework for local Policy and Procedures 01-06 Decontamination of Flexible endoscopes: Policy and management (CFPP 01/06) and BSG Guidance for Decontamination of Equipment for Gastrointestinal Endoscopy; The Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee March 2014, Revised November 2016. 1.4 Flexible endoscopes are used within Trust managed Community Hospital sites as follows; Nasendoscopes; at the following locations; Minehead Community Hospital; Bridgwater Community Hospital; Burnham on Sea Community Hospital; West Mendip Community Hospital; Chard Community Hospital; Shepton Mallet Community Hospital Cystoscopes; at the following locations; Minehead Community Hospital Day Unit; Bridgwater Community Hospital Outpatient Department. 2. PURPOSE & SCOPE 2.1 In order to prevent the potential for transmission of infection each endoscope and device must be decontaminated with the same rigour following every endoscopic procedure. The guidance contained within, CFPP 01/06 and manufacturer s instructions should be followed. 2.2 This policy applies to all staff involved in the provision care of to patients undergoing an endoscopic procedure within Trust managed services. 2.3 Non lumened endoscopes are used within Somerset Partnership NHS Trust managed locations, and therefore this Policy DOES NOT cover lumened Endoscopy equipment. 3. DUTIES AND RESPONSIBLITIES 3.1 Director of Infection Prevention and Control - Executive staff member responsible for Trust Decontamination and ensuring decontamination processes used throughout the Trust are according to national standards. Reports risk to the Board. V3-4 - December 2017

3.2 Trust Decontamination Lead- Advises Director of Infection Prevention and Control as regards any shortfalls against National and European Directives or Guidance and ensures that effective quality control and monitoring systems are in place for the decontamination of reusable devices. 3.3 Day Case/Out Patient Department Unit Lead - Day to day Management of Department and ensuring decontamination of flexible Endoscopes and associated items are maintained to required standards as stated in this policy. This post should also make sure all staff are trained to required standard. 3.4 Staff involved in endoscope decontamination All staff involved in decontamination of flexible endoscopes are responsible for: Ensuring they have received training and assessed as competent to carry out the process; Ensuring they follow the decontamination process as outlined in this policy 3.5 Infection Prevention and Control Team - To support all named parties in this policy as regards infection prevention and control issues and give advice as required 4. DEFINITIONS 4.1 Decontamination: A process which removes or destroys contamination so that infectious agents or other contaminants cannot reach a susceptible site in sufficient quantities to initiate infection or any other harmful response. 4.2 Flexible Endoscope: A flexible Instrument with a fibreoptic camera which is passed into an area of the body (e.g. the bladder) which allows a greatly magnified image to be projected onto a screen. 4.3 Nasendoscope: A flexible endoscope used to explore the nasal passages, larynx, and oropharynx. 4.4 Cystoscope: A flexible endoscope used to explore the urinary tract and bladder. 4.5 Creutzfeldt-Jakob Disease (Cjd) And Variant Creutzfeldt-Jakob Disease (Vcjd) - Transmissible spongiform encephalopathies (TSEs) are a group of diseases which affect both humans and animals. 4.6 SSD: Sterile Services Department; an integrated place in hospitals and other healthcare facilities that reprocesses sterilization and other actions on medical devices 5. FLEXIBLE ENDOSCOPY SERVICE 5.1 An Endoscopy ( Cystoscopy) service is delivered via Bridgwater and Minehead Community Hospitals. 5.2 The Minehead based service is delivered via the Hospital Day Surgery Unit, and is managed via a locally appointed lead, who has received appropriate training to V3-5 - December 2017

manage the decontamination facilities within this location. The Bridgwater Community Hospital based service is delivered via the Outpatient Department. The activity generated within this site is owned by Taunton and Somerset NHS Foundation Trust. 5.3 The Endsocopy activity delivered via Minehead Day Case unit and Bridgwater OPD are owned by Taunton and Somerset NHS Foundation Trust, with Somerset Partnership NHS Foundation Trust managing the premises and providing clinician support. 5.4 The process for decontamination of cystoscopes between patients has been agreed between Taunton and Somerset NHS Foundation Trust and Somerset Clinical Commissioning Group. The agreed process will involve the use of a sheathed cover for the endoscope, with the endoscope being manually decontaminated between patients via the use of the Tristal 3 wipe system. Training for this process is provided via the Sheath product manufacturer. For any system breaches, equipment will be decontaminated via the Taunton and Somerset managed SSD service 5.5 Nasendoscopy is undertaken in a proportion of the community hospital settings (see section 1.4) and manual cleaning is utilised for the decontamination of this equipment, using the Tristal three stage cleaning process. All staff in these locations are required to receive training to ensure full compliance with the decontamination process. 6. DECONTAMINATION PRINCIPLES ( see also Appendix 1) 6.1 General Decontamination Principles for Flexible Endoscopes Decontamination of endoscopes should begin as soon as possible after use.. Flexible endoscopes entering sterile body cavities must have undergone a sterilisation process OR be using the single use sheath system. It is important that staff are familiar with the equipment they are responsible for decontaminating, testing and maintaining. Standard infection prevention and control precautions apply and appropriate personal protective equipment must be readily available and should be used to protect the healthcare worker, from exposure to biological agents and toxic chemicals. All staff responsible for flexible endoscope decontamination must have been trained for the role. A record should be kept of all training given and levels of competencies achieved as per the Staff Training Matrix. Safe working practices in the decontamination area should be written down and understood by all staff. Decontamination of endoscopes/nasendoscopes must be undertaken between patients, at the beginning and end of each list by staff trained for the purpose. The department should be followed. A record should be kept of the serial V3-6 - December 2017

number of each endoscope and each re-useable accessory used in each patient. This is important for any future contact tracing when possible endoscopic transmission of disease is being investigated. It is essential that all decontamination stages are included after every use of the endoscope and that none are omitted. Endoscopy should be avoided wherever possible in patients with suspected or confirmed CJD. A dedicated endoscope should be used and fully cleaned and decontaminated via the Taunton and Somerset NHS Foundation Trust CSSD after use. The scope should then be quarantined and may be reused exclusively on the same individual patient if required. For further details see CJD policy. 7. LOCAL MONITORING (see Appendix 1) 8. TRAINING REQUIREMENTS 8.1 Local Leads will disseminate training as per the requirements of the equipment manufacturer s training and guidance 8.2 Equipment Manufacturer will support locally based training. 8.3 The Trust will work towards all staff being appropriately trained. 9. MONITORING COMPLIANCE AND EFFECTIVENESS 9.1 The policy will be monitored via Trust Theatre and Endoscopy Group which reports to the Infection Prevention and Control Assurance Group. Quarterly Infection Prevention and Control Reports include Endoscopy related information and are submitted to the Trust Clinical Governance Group who report directly to the Trust Board. 9.2 An audit of flexible endoscope decontamination will be carried out annually by the Department Lead to check that all procedures are being followed and the flexible endoscopes are in good state of repair. A report highlighting any non-conformity will be sent to the Theatre and Endoscopy Working Group for further investigation and an action plan developed to rectify any issues. Progress against these action plans will be monitored via the Theatre and Endoscopy Working Group and also the Trust Infection Prevention and Control Assurance Group (IPCAG). Exceptions will be reported via the IPCAG via The Trust Clinical Governance Group. 10. REFERENCES, ACKNOWLEDGEMENTS AND ASSOCIATED DOCUMENTS - Department of Health publications (England only): Choice Framework for local Policy and Procedures 01-06 Decontamination of flexible endoscopes: Operational management manual 13536:1.0. V3-7 - December 2017

- Musgrove Park Hospital, Taunton and Somerset NHS Foundation Trust Decontamination of Flexible Endoscope Equipment Policy; - The Health and Safety at Work Act and associated Regulations; - The Control of Substances Hazardous to Health Regulations; - EU Council Directive 93/42 EEC concerning Medical Devices; - EU Council Directive 99/44 EEC concerning product liability; - Health Technical Memorandum 01-01 Decontamination of reusable medical devices; - Health Technical Memorandum 03-01: Specialised ventilation for - healthcare premise ( Sections A&B); - BSG Guidance for Decontamination of Equipment for Gastrointestinal Endoscopy; the Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee March 2014, Revised November 2016. Cross reference to other procedural documents - Cleaning of equipment and decontamination policy (to be read in conjunction with the medical devices policy); - Creutzfeldt-Jakob disease (CJD) policy; - Hand Hygiene Policy; - Infection Control Surveillance Policy; - Infection control: standard infection control precautions policy (incorporating blood and body fluid spillage) Policy; - Learning Development and Mandatory Training Policy; - Risk Management Policy and Procedure; - Staff Mandatory Training Matrix (Training Needs Analysis); - Untoward Event Reporting Policy and procedure; All current policies and procedures are accessible in the policy section of the public website (on the home page, click on Policies and Procedures ). Trust Guidance is accessible to staff on the Trust Intranet. STANDARD OPERATING PROCEDURE APPENDIX 1 V3-8 - December 2017

General Decontamination Principles for Endoscopes and Nasendoscopes A scientifically validated product must be used when manual decontamination is being undertaken. The approved product is the Tristel Sporicidal Wipes System which incorporates;- Pre-clean wipe; Sporicidal wipe; Rinse wipe. Do NOT use if the wipe sachet or foam bottle has been damaged. 1) Use Tristel pre-clean wipe to decontaminate the instrument, open sachet to activate foam of the enzymatic, proceed to wipe over instrument including cord for 20 seconds. 2) Second step in decontamination process is to put on clean gloves and apron. Using Tristel Sporicidal Wipe sachet pump 4 measures of activator foam onto sporicidal wipe, scrunch to mix active ingredients, wait 15 seconds, wipe the surface of the instrument ensuring all areas have come in contact with the solution, all areas of the surface must come into contact with the wipe at least once. Wait 30 seconds. 3) Third step open Tristel Rinse Wipe sachet and wipe over instrument, place the cleaned instrument onto a clean paper towel. The Rinse wipe is utilised to remove and neutralise chemical residues from the surface. 4) Dispose of paper roll into clinical waste bag. 5) Remove and dispose of gloves into clinical waste bag. 6) Wash and dry hands. 7) Complete audit book (for traceability), remove both labels from the book of the sporicidal wipe, place one label in the patients chart and one label in the audit book. 8) Repeat above process between each patient and at the end of the clinic decontaminated equipment should be returned to storage area. Precautions and Considerations The cleaning and disinfection of Nasendoscopes requires a high-level disinfection process. Cleaning of Nasendoscopes is to be performed between each patient examination MONITORING (AUDIT/TRACEABILITY TRAIL) Tristal 3 Stage Decontamination Process V3-9 - December 2017

Maintain log book. Entry required for each patient; At the completion of each list, all patient s records must be completed; When the log book is completed, sign off on front cover and archive; The scope is to be checked post each clinical intervention for any evidence of breach; In the event of identifying a breach, the scope will be cleaned as per the TrIstal Three stage decontamination process and sent to Taunton and Somerset NHS Foundation Trust, to undergo an automated sterilisation process. A report will be submitted via the DATIX Incident reporting system, detailing actions taken. WEEKLY TESTS Flexible Endoscopes: For each endoscope prior to use; Check the integrity of the insertion tube and the distal end Check the entire endoscope as described in the manufacturer s instructions.. V3-10 - December 2017