Lateral Transfers Boosting Turning Positioning Proning

Similar documents
THE INTERVENTIONAL PATIENT HYGIENE COMPANY

Chapter 14. Body Mechanics and Safe Resident Handling, Positioning, and Transfers

Understand nurse aide skills needed to promote skin integrity.

VHA Safe Patient Handling and Mobility Algorithms (2014 revision) Algorithm 4: Reposition in Chair: Wheelchair, Dependency Chair or Other Chair

Safe Patient Handling:

Solutions to Challenges Associated with Bariatric Patients

We Have Your Back A Worker Safety Collaborative An Initiative of the Florida Hospital Association

Redefining Patient Handling. prevention

The Ergonomics of Patient Handling

*Before instructing class carefully review Transfer Sheet User Guide*

Eleganza 3XC. Designed for ICU

Considerations for Bariatric Patients in Pressure Injuries and Wound Care. April 27, 2017

Handling the Bariatric Patient: Ergonomic Issues HoverTech International All Rights Reserved

OR Positioning and Pressure Injury Prevention. September 13, Ann N. Tescher, APRN CNS, PhD, CCRN, CWCN Debra L.

ConCerto Shower trolley

Pressure Ulcers ecourse

Pressure Injuries. Care for Patients in All Settings

Safe Patient Movement and Mobility Improving Outcomes for Patients and Employees. Objectives. Your Presenter. Vision

Facility and Equipment Assessments and Hands-on Equipment Training

Introduction. Welcome to Human Care.

Safe Lifting the BFA Way

CARINO. with people in mind

How effective is your pressure reducing surface?

PRESSURE ULCER PREVENTION

Redefining Patient Handling. prevention

PRESSURE ULCER PREVENTION SIMPLIFIED

User Guide (0108) Barton Ceiling Track Lift

DO NOT DUPLICATE. Pressure ulcers remain a huge burden, in terms of financial cost to the

LikoGuard Overhead Lift System Enhancing patient safety

Development of SPH and ISO implemented in the United States

Wound Care and. February Lymphoedema Service

Wound Care Program for Nursing Assistants- Prevention 101

CARINO. with people in mind

See the Pressure you re up against...

Affinity Four Birthing bed Delivering Safety

Safer mattresses. Effective and proven pressure ulcer prevention & therapy

Citadel Plus Bariatric Care System

Park Nicollet Health Services

Propad MATTRESS OVERLAYS, CUSHIONS AND ACCESSORIES MSS. Distributed by:

CARMINA BARIAtRIC shower CoMMode ChAIR

Alaina Tellson, PhD, RN-BC, NE-BC

InTouch Critical Care Bed. Basic needs. Simplified care. Exceptional outcomes.

10/12/2017 QAPI SYSTEMATIC ON-GOING CHANGE. Governance & Leadership

Guidelines. Homes. Ergonomics. Musculoskeletal Disorders. for Nursing. for the Prevention of

Wound, Ostomy and Continence Nursing Certification Board (WOCNCB) Advanced Practice (AP) Wound Care Detailed Content Outline

PATRAN SLIDE SHEETS AN INEXPENSIVE WAY TO START A SAFE-PATIENT-HANDLING PROGRAM

Pressure Ulcers (pressure sores)

Wound, Ostomy and Continence Nursing Certification Board (WOCNCB) Advanced Practice (AP) Wound Care Detailed Content Outline

Seba: Supine to Seated Edge of Bed Solution

Medical. InTouch. Basic Needs. Simplified Care. Exceptional Outcomes. Stryker InTouch Critical Care Bed

CARINO HEIGHT ADJUSTABLE HYGIENE CHAIR

Centrella Smart+ Bed Because life-altering moments deserve elevated care

Centrella Smart+ Bed. Because life-altering moments deserve elevated care

Protection and Convenience For You and Your Patient

They are updated regularly as new NICE guidance is published. To view the latest version of this NICE Pathway see:

CArEnDO ElECtrIC HyGIEnE CHAIr

PUSH for FACT # 1. Quality Patient Care! What are the Facts about Safe Patient Handling and Movement?

Soteria Strains Safe Patient Handling and Mobility Program Guide

4/16/2018. QAPI Quality Assurance Performance Improvement QAPI SYSTEMATIC ON-GOING CHANGE.

Safe Patient Handling and Mobility for Home Care. Audrey Beauvais, DNP, MBA, CNL, RN, and Lenore Frost, PhD, OTR/L, CHT

Reducing Bed Mobility Injuries of ICU Nursing Staff. Through Body Mechanics Retraining. Human Factors in QAS. Spring 2008 Term Project

Introduction. Welcome to Human Care.

PURPOSE: POLICY: FACTS:

TO BE RESCINDED Hospital beds, pressure-reducing support surfaces and accessories.

showering solutions Create a safe, efficient and dignified care environment

Challenge Scenario. Featured TAG TOPIC SCENARIO NOTES F314

The first step to early mobilization, patient satisfaction and caregiver safety.

Pressure Injury (Ulcer) Prevention

BOARD OF DIRECTORS PAPER COVER SHEET. Meeting Date: 1 st December 2010

CARENDO ERGONOMIC HYGIENE CHAIR WITH UNIQUE CARE RAISER

3M Infection Prevention Patient Warming Product Brochure. Warm. Every. Patient

Hospital Acquired Pressure Ulcers The Rhode Island Hospital Experience. Quality Partners of Rhode Island November 15, 2006

Pressure Ulcer/Pressure Injury Road Map

Bariatric. Care Solutions

This report summarizes the ergonomic risk assessment conducted at a Hospital August 2001.

OUTLINE SPH NEW HIRE TRAINING

Step by step instructions for each team member when lifting or repositioning patients with suspected or known spinal injury.

sample Pressure Sores Prevention & Awareness Copyright Notice This booklet remains the intellectual property of Redcrier Publications L td

2010 Innovative Uses and Tips for Safe Patient Moving Equipment: Safe Patient Moving: the Keys to the Kingdom: Learning Objectives

INCIDENCE OF PRESSURE ULCERS IN THE ELDERLY:

EasyCare Maximizing Care, Comfort and Safety

Expression of Interest for Wound Care Project

Introduction. Pressure Ulcers. EPUAP, NPUAP Pressure Ulcer Categories. Current Clinical and Political background CLINICAL CASE STUDY

Strengthen Patient Care by Reducing Hospital Acquired Pressure Ulcers (HAPU)

Ave 2 Birthing Bed. Welcome to the world

PRESSURE ULCER PREVENTION

Prevention of Pressure Ulcers

Pressure Injuries and Pressure Care

Safe Patient Handling MN Statute Legislation to change out-dated work practices

How to Prevent Pressure Ulcers. Advice for Patients and Carers

PRESSURE ULCER PREVENTION

The right ancillary services can be as important as the right medication.

Contractor Information. LCD Information

Infection Control - Romy reinforces basic principles

Information on How to Prevent Pressure Ulcers ( Bedsores ) for Patients, Relatives and Carers in Hospital and in the Community

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

New data from Minnesota hospitals offers more insight into preventing

A PRACTICAL GUIDE TO RESIDENT HANDLING

QUESTIONS PERTINENT TO PRODUCT SELECTION:

Safe Patient Handling: Reducing Risk through Evidence-Based Interventions Susan Lennon Salsbury OTR/L CDMS Associate Health OhioHealth

Transcription:

Lateral Transfers Boosting Turning Positioning Proning

Facilitate all-day patient care with the HoverMatt Single-Patient Use Air Transfer System. Designed to be multifunctional, the HoverMatt Single-Patient Use (SPU) Air Transfer System makes patient transfers, boosting, positioning and proning easier, while protecting caregiver safety. A cushion of air beneath the inflated HoverMatt SPU reduces the force required to move a patient by 80-90%, enabling caregivers to safely transfer patients without lifting or straining. By reducing injuries related to lateral transfers and repositioning, the HoverMatt SPU helps to improve staff retention while meeting legislative guidelines for safe patient handling. Improves Patient Comfort & Safety Breathable top layer dries quickly and stays cool, allowing the SPU to be left under the patient Inflated mattress cradles the patient while moving them in a stable position, eliminating skin shear and bruising and providing comfort to patients in pain Reduces Cost Single-patient use product eliminates costs and logistics associated with reprocessing, while greatly reducing the risk of cross-contamination Air-assisted technology is proven to reduce workplace injuries and associated costs 50-100% when implemented into a Safe Patient Handling Program Facilitates Care Throughout the Facility With a 1200 lb. weight limit, one device can be used for multiple patient handling tasks across the facility, including in Radiology, Diagnostic Imaging and ancillary departments Supports Safe Patient Handling recommendations and guidelines for increased healthcare worker safety from OSHA, AORN, NAON and ANA HT-Air 1200 Air Supply offers six airflow options, including a setting that can be used to inflate the HoverMatt slowly for sensitive patients and ensure proper positioning prior to full inflation.

Ortho, L&D and UroGyn Specifically designed for use in the OR and Labor and Delivery, the HoverMatt SPU Half-Matt delivers the same safe and easy patient transfers as the standard HoverMatt but in a shorter length. At 45" long, the SPU Half-Matt ends right below the buttocks to accommodate specialty tables. It is ideal for use during arthroscopy, cystoscopy, labor and delivery, and other gynecological or urological procedures as an effective yet unobtrusive patient transfer device. Bariatrics and UroGyn The HoverMatt SPU Split-Leg Matt is a specialty transfer mattress designed for use in the lithotomy position or on surgical tables when split-leg attachments are used. The SPU Split-Leg Matt has a patented design that separates the bottom half of the transfer mattress into two individual segments, or "legs." These legs snap together for effortless lateral patient transfers and are then unsnapped for convenient positioning on the procedure table.

Hovertech advantages Innovative market leader focused on customer needs Extensive air-assisted lateral transfer device product line Comprehensive compatibility safety testing: Pressure Mapping MRI Compatibility Radiolucency Attenuation Wound Care OR Particle Test Electrosurgery Compatibility Heat Transfer Static Testing Flammability Equipment acquisition programs including the HT-Air Placement Program, HT-Air Rental Program, and HoverTech Rewards Program Professionally trained, account-dedicated sales and customer service representatives Safe Patient Handling Healthcare Ergonomics Lifting Program (HELP SM ) provides consultative services to assist facilities to develop or improve a SPHM program The HoverSling Lift & Transfer Device combines the HoverMatt SPU and a lift sling into one product to streamline patient handling and reduce costs. The HoverSling offers all of the benefits of the HoverMatt for lateral transfers, boosting, turning and repositioning. When used as a lift sling, the HoverSling s patented design cradles the patient s limbs evenly and securely for greater patient comfort. This unique product can also be used as a limb lifter or stabilizer for wound care and Labor and Delivery applications.

Wound care management Wound care and prevention are critical for the vast majority of patients in acute care, long term care and home care settings. The prevalence of pressure ulcers is a major concern, as they can lead to additional healthcare costs and a decline in a patient's health. Managing the microclimate of the skin, reducing pressure and minimizing friction and shear are some of the most significant factors for wound care management. The HoverMatt SPU can be left under patients to assist with transfers and repositioning, while mitigating these wound care risk factors. Because it makes turning and repositioning easier for caregivers, use of the HoverMatt SPU can also help to improve adherence to Q2 turning protocols. Friction & Shear When the HoverMatt SPU is inflated, the patient is moved on a stable cushion of air, eliminating friction and shear caused by the opposing pull forces of the tissue and bone. Heat & Moisture The top layer of the HoverMatt SPU has high wicking and moisture evaporation properties, which are well above the industry breathability threshold. This helps prevent moisture and heat build-up under the patient to mitigate skin issues and promote wound healing. Pressure Mapping There is <1% difference in interface pressures between the low air loss baseline measurement and the HoverMatt SPU. Pressure mapping and clinical trials conclude that there is no increase in risk of pressure ulcers with the use of the HoverMatt SPU, allowing clinicians to safely leave it under the patient for all-day care. Baseline Measurement: Low air loss mattress, sheet, pressure sensing device, 200 lb. patient Low air loss mattress, sheet, pressure sensing device, SPU, 200 lb. patient Lloyd, JD, Biomechanical Evaluation of Pressure Distribution During Extended Use of HoverMatt Technology; October 26th, 2010 Deter L, Kiely D, White-Chu EF. A Descriptive View of the Impact of an Air-Assisted Device on Pressure Ulcer Prevention and Healing. AM J SPHM. December 2013; Vol. 3, No. 4, 138-143.

Product specifications Sewn construction Top: Non-woven polypropylene fiber Bottom: Nylon fabric Latex free HoverMatt Single-Patient Use (10 Per box) 34" W x 78" L HM34SPU 39" W x 78" L HM39SPU 50" W x 78" L HM50SPU (5 Per box) HM50SPU-1Matt (1 Unit) Weight limit 1,200 pounds Patent No(s). 7,373,680; 7,712,170 HoverMatt SPU Half-Matt (10 Per box) 34" W x 45" L HM34SPU-HLF 39" W x 45" L HM39SPU-HLF Weight limit 1,200 pounds Patent No. 6,073,291 HoverMatt SPU Split-Leg Matt (10 Per box) 34" W x 64" L HM34SPU-SPLIT Weight limit 1,200 pounds Patent No(s). 6,073,291; 7,266,852; 7,406,723; 7,574,761 HoverSling (10 Per box) 34" W x 64" L HMSLING-34 Weight limit 700 pounds 39" W x 64" L HMSLING-39 50" W x 64" L HMSLING-50 Weight limit 1,000 pounds Patent No(s). 7,373,680; 8,566,977; 7,266,852; 7,574,761; 7,712,170 Compatible with HoverTech Air Supplies Air200G (800W), Air400G (1100W), and HTAIR1200/2300 (Variable Speed) The Single-Patient Use HoverMatt and HoverSling should not be reprocessed. If the devices are laundered, the DO NOT WASH label at the foot end of the product will dissolve and state DISCARD IMMEDIATELY. 4482 Innovation Way Allentown, PA 18109 800.471.2776 Fax 610.694.9601 www.hovermatt.com Info@HoverMatt.com Bro_spu_0816