UnoMeter Safeti Plus Hourly Diuresis Monitoring System

Similar documents
URINARY CATHETER MANAGEMENT CARE PLAN

Best Practice Guidelines BPG 5 Catheter Care

Undertake care for individuals with urinary catheters

Early discharge with Exudrain wound drains NURSING INFORMATION ON THE CARE OF BREAST SURGERY PATIENTS AT HOME

Goal Statement: Achieve reduction in CAUTI events by review and implementation of best practices for utilization and management.

In 2008, the Centers for Medicare & Medicaid Services

PROVISION OF CATHETER CARE BY SUPPORT WORKERS IN THE COMMUNITY

Supplement 1. Procedure 35: Assist to Bathroom

Policy for use of the Royal Marsden Manual of Clinical Nursing Procedures (9th Edition)

Thopaz. Einführung. Welcome to the age of digital thoracic drainage therapy! «What I want... is a safe and efficient drainage therapy»

St. Vincent s East Page 1 of 5

Running head: EBN & CAUTIS 1

Giving Intravenous (IV) Nutrition Through a Central Line with a CADD Pump

Remove catheters as soon as possible, care for catheters individually

CAUTI Reduction A Clinton Memorial Presentation

CHANGING BEHAVIOR BY DESIGN.

Going home with a redivac drain after surgery

Administration of urinary catheter maintenance solution by a carer

Application for Clinical / Medical Waste Collection

ASEPTIC TECHNIQUE LEARNING PACKAGE

Infection Prevention & Control Orientation for Housestaff Welcome to Shands at UF!

Keeping fit to stay healthy

#29 & #30 MEASURING INTAKE AND OUTPUT/WOUND DRAINAGE SYSTEMS (TEST)

Eliminating Catheter-Associated Urinary Tract Infections: Implementing a Quality Improvement Project

Indwelling Urinary Catheters: A One- Point Restraint?

Section G - Aseptic Technique. Version 5

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

Learning Objectives. Successful Antibiotic Stewardship. Byron Health Center & GrandView Pharmacy

Go with the Flow: Working together to improve bladder health and reduce urinary tract infections

Multi-Link. X2 ECG System. Choose flexibility and quality for your reusable and disposable single-patient-use leadwires

Carbapenemase Producing Enterobacteriaceae (CPE) Prevention and Management Toolkit for Inpatient Areas

Healthcare-Associated Infections

PATIENT CARE MANUAL PROCEDURE

1. Infection Control, Centers for Disease Control and Prevention (CDC). (2002). Guideline for hand hygiene in health-care settings

GOING HOME WITH A NEPHROSTOMY TUBE PATIENT INFORMATION

Ambulatory Chest Drainage System Chest Bag

The percent of skilled nursing facility (SNF) residents who have

PERSONAL CARE WORKER (PCW) - Job Description

THE NEUMA PICC AND CENTRAL LINE PROTECTION CLAMP Introduction and Frequently Asked Questions

Catheterisation and competency. Allison Robertson CNS Urology

Running head: NURSING REASEARCH AND MY EBN PRACTICE 1

LAPAROSCOPIC SIMPLE REMOVAL OF THE KIDNEY

Setting a new standard for performance, safety and simplicity

21 st Century Health Care Consultants

Learning Objectives. QAPI at a Glance: 8/22/16. Achieving Success with QAPI. Participants will be able to describe:

Hospital Acquired Conditions. Tracy Blair MSN, RN

CAUTI reduction at Mayo Clinic

THERMAL PRINT PROCESS LATEX FREE CONSTRUCTION EASY TO FIT TO PATIENT SECURED BY TAMPER EVIDENT CLASP ADJUSTABLE LENGTH BRACELET

What is a Mitrofanoff?

your hospitals, your health, our priority CATHETERISATION Urethral/ supra-pubic POLICY NAME: VERSION NUMBER : 1 PROFESSIONAL ADVISORY BOARD (PAB)

patientinformation Peripherally inserted central catheter (PICC) Vascular Access The Rotherham NHS Foundation Trust

Policies and Procedures. RNSP: RN Procedure. I.D. Number: 1067

Level 2 Award in Health and Safety in Health and Social Care

More comfortable childbirth

About the Critical Care Center

Clinical guideline for insertion and removal of an intermittent urethral catheter

Five Top Tips to Prevent Infections in Long-term Care Settings

Clinical Intervention Overview: Objectives

Adult Protocol Intermittent Catheterisation

The Safe Use of Sharps in Healthcare Guidance for managers and staff

ENTERPRISE with people in mind

Chapter 15 8/23/2016. Specimen Collection and Diagnostic Testing. Diagnostic Examination. Diagnostic Examination (Cont.)

Continence & Catheter Training For Nursing Homes For Jan-June 2016

Infection Prevention - Changing Practice in Catheter Management

Intravenous Medication Administration via a Central Venous Line

Percutaneous Nephrostomy Tube

The Clatterbridge Cancer Centre. NHS Foundation Trust MRSA. Infection Control. A guide for patients and visitors

Nurse Driven Foley Removal Protocol. Cathy Moore, MSN, ACNS-BC, CCRN 2009

Spotlight on Visual Management

Risk Assessment Form HS 9 (1)

Cleaning a Wound and Applying a Dry, Sterile Dressing

Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use

SARASOTA MEMORIAL HOSPITAL

C: Safety. Alberta Licensed Practical Nurses Competency Profile 23

AvantGuard bed Safety by design. Information

Running head: PREVENTING UTIS 1

Alaris Products. Protecting patients at the point of care

First Aid Policy. Appletree Treatment Centre

Bladder Instillation Therapy (Mitomycin) Department of Urology Information for patients

ANTT. What is it and do you need to know? Grampians Region Infection Control Group Sue Atkins Regional Infection Control Consultant

Adopting New Enteral Connectors

LESSON ASSIGNMENT. Environmental Health and the Practical Nurse. After completing this lesson, you should be able to:

Launch Team Tool Kit

Real Time CLABSI Case Reviews at HCMC. Mary Ellen Bennett Steph Laskowski

LAPAROSCOPIC RADICAL REMOVAL OF THE KIDNEY AND URETER

State-Approved Curriculum NURSE AIDE I TRAINING PROGRAM July 2013 Appendix and Resources

4/30/2012. Disclosure. Housekeeping. The Role of the Infection Preventionist on the Value Analysis Committee. Boyd Wilson

This leaflet can be made available in other formats including large print, CD and Braille and in languages other than English, upon request.

This document is NOT FOR PROMOTIONAL USE. Do not copy, distribute, or share with physicians, staff, or patients. FOR INTERNAL USE ONLY.

Eleganza 3XC. Designed for ICU

CYSTOSCOPY AND URETHRAL BULKING INJECTIONS

The Urine Dipstick: A Quick Way To Over-Treat! Ann McFeeters, RN Infection Control Practitioner September 26, 2012

Ampera bed. Trusted performance for all care environments

Goal Elements of Performance APIC Comments APIC Recommendations

90207/90217 Ambulatory Blood Pressure Systems

Preparing for the 2015 QIS Changes in abaqis

MAINTAINING a closed system to reduce

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

Commissioning for Quality & Innovation (CQUIN)

Hickman line insertion and caring for your line

Transcription:

UnoMeter Safeti Plus Hourly Diuresis Monitoring System

Hourly Diuresis For patients, for nurses, for better care Hourly diuresis is much more than just a measurement. It is a clear indicator of a patient s condition. We understand the important link between urine meters and patient care and have created a safe and intuitive system. Our Circle of Hourly Diuresis explains the many features and benefits of the UnoMeter Safeti Plus system for patients and carers so you can be sure you are making the right choice when choosing a urine meter.

UnoMeter Safeti Plus Hourly Diuresis Monitoring System For intensive care patients only the best will do The importance of accurate urine monitoring The condition of a critical patient can change from one hour to the next. This makes accurate hourly monitoring of urine production a significant indicator of patient condition. Although simple to do, this procedure is often one of the most common causes of infection, especially for critically ill patients. Based on the high demands healthcare professionals place upon their equipment, the UnoMeter Safeti Plus system allows nurses to provide the highest standards of patient care. Proven infection control 2 At ConvaTec, our urine meters have always been associated with infection control and the UnoMeter Safeti Plus system, our latest offering, is no exception. As one of the most welldocumented urine meters on the market, the UnoMeter Safeti Plus system is designed to offer the highest level of infection control available. The small details make the biggest difference With the UnoMeter Safeti Plus system, we have striven to meet the current daily demands of nurses and healthcare professionals. In addition to improved patient safety, the UnoMeter Safeti Plus system is even easier to use than its predecessor, with extra details such as faster chamber emptying and drainage time and improved hanging features.

Infection Prevention Protecting patients at risk Nosocomial urinary tract infections account for up to 40% of all hospital-acquired infections 1. In vitro tests have documented that the UnoMeter Safeti Plus system prevents contamination via the KombiKon needle free sample port and retrograde infection via 2 non-return valves (NRVs) 2,3. Infection Control > 2 non-return valves to minimise retrograde infection > Closed system to minimise cross contamination and UTI > Compact system to minimise the risk for contamination from the floor > Evidence of reduced risk of retrograde infection 2 > Double lumen tubing to minimise urine stasis > Evidence of contamination prevention through the KombiKon needle-free sample port 3 > Top-mounted system to minimise retrograde infection 2

Compact system reduces the risk of contamination from the floor Non-return valve built into the connector prevents residual urine from re-entering the Foley catheter Non-return valve in the collecting bag designed to prevent retrograde infection² Double lumen tubing allows emptying into chamber before measurement KombiKon needle-free sample port prevents contamination 3 Anti-kink spiral in tubing reduces risk of urine stasis Enhanced 5ų bacteria-proof hydrophobic air vents secure constant airflow through the system Top-mounted chamber minimises risk of retrograde infection²

Nurse Safety KombiKon - needle-free sample port Accidental needle stick is one of the most common dangers to nurses in their working environment 4. With KombiKon, our unique needle-free sample port, the UnoMeter Safeti Plus system protects nurses from needle stick injuries. Furthermore, testing demonstrates that the KombiKon sample port reduces the risk of contamination in the system.³ KombiKon - needle free sample port > No risk to the nurse of needle stick injuries > Universal port can be used with most standard syringes > Easy to clean sample port How to use Insert tip, turn, draw urine sample

Intuitive Design The confidence to care Throughout development, the UnoMeter Safeti Plus system has been extensively tested by nurses and design experts, which has resulted in a simple and intuitive design. This reduces the time required for training and leaves nurses confident that they are providing the best possible care for their patients. Intuitive Design > Flexible hanging options for different bed designs > Comfortable open/close system > Face up during transportation > Minimal training required > Easy-to-read linear scale > Easy-to-use bottom outlet Improved flexible hanging options Intuitive design requires minimal training Compact and functional design of bag and bottom outlet Transported face up when patients are moved

Optimised Nursing Time saving without compromising reliability During the development phase of the UnoMeter Safeti Plus system, significant time was spent observing how nursing staff monitor urine output. We found that they needed a urine meter that could save time yet remain reliable. The UnoMeter Safeti Plus system has therefore been designed to enable nurses to spend less time on routine procedures and more time caring for patients. Optimised nursing > Fast chamber and bag emptying > Comfortable open/close system > Easy-to-operate bottom outlet > Large digits on chamber for easy and accurate measurements Fast chamber and bag emptying Easy-to-operate bottom outlet Easy-to-read scale with large digits for accurate measurements Comfortable open/close system

For all Patients Whatever the situation, whoever the patient Very often a urine meter is changed as a patient moves from one hospital department to another. For patients, this increases their risk of infection and for the hospital it increases costs. The UnoMeter Safeti Plus system was designed for all types of patients and to be hung on all types of beds. It can be used in the Operating Room, Intensive Care Unit, Emergency Department and other Specialist Wards and while connected to the patient, it can easily be transported between each department. The UnoMeter Safeti Plus system is also compatible with the full range of Foley catheters. For all patients > Can be used in Operating Room, Intensive Care Unit, Emergency Department and other Specialist Wards > Flexible hanging options for use on all bed types > Transported face up when patients are moved > Detailed graduation in main chamber for accurate measurements even for low urine output patients and paediatric patients > Compatible with all Foley catheters > Cost-effective potential Transported face up when patients are moved Flexible hanging options for use on all bed types TotalCare bed from Hill-Rom - the balanced UnoMeter Safeti Plus system

Our world is what we make of it ConvaTec is a global company committed to serving healthcare professionals, hospitals and patients worldwide. In the ConvaTec Continence and Critical Care division, we specialize in the development, manufacturing and distribution of single-use devices to hospitals and healthcare sectors around the world. We are proud of our strong tradition of innovation and dedication to providing solutions. It is this legacy of ingenuity and invention that allows us to find answers to the challenges health care professionals and ordinary people are confronted with in their daily lives. Ref.: ¹ Kalsi J, Wilson P, Mundy A. Hospital acquired urinary tract infection. Intern J of Clin Pract.2003;57(5):388-391. 2 Frimodt-Møller N, Corneliussen L. In vitro test of different urine-meters in an experimental bladder-drainage model: prevention of ascending contamination depends on construction of the urine meter. British J of Infect Control 2005;6(5):14-17. ³ Tvede M. Performance of KombiKon needle free sample port. Test Report, July 2004, data on file, ConvaTec. 4 Needlestick Prevention for Worker Safety: Sharps Injuries Still a Leading Occupational Hazard, Environment of Care News, August 2005, Volume 8, Issue 8. UnoMeter Safeti Plus Hourly Diuresis Monitoring System Description Reference Box Qty. 2.0L Fixed, straps and round hooks, 150 cm, free flow 158101310190 14 2.0L Fixed, straps and round hooks, 110 cm, free flow 158100510190 14 2.0L Fixed, straps, 150 cm, free flow 158101210190 14 2.0L Fixed, straps, 110 cm, free flow 158100410190 14 / indicates trademark of Unomedical a/s unless otherwise noted. The ConvaTec Logo and Our world is what we make of it are trademarks of ConvaTec Inc. TotalCare is a trademark of Hill-Rom Services, Inc. 2009 Unomedical a/s. AP-008496-MM Unomedical a/s A ConvaTec Company Birkerød Kongevej 2 DK-3460 Birkerød Denmark Phone +45 48 16 70 00 Telefax +45 48 16 70 45 E-mail mail@unomedical.com www.unomedical.com www.convatec.com 0312-2010-02 GB