L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION

Similar documents
Engineering Waiver Management

Inspection and Testing of Signalling - Roles, Responsibilities & Authorities

Buck & Boost Transformer Installation Instructions

Railway Interoperability and Safety Committee. Working document

Australian Standard. Clinical investigations of medical devices for human subjects. Part 1: General requirements AS ISO ISO :2003

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

COMMISSION DIRECTIVE 2011/18/EU

Australian/New Zealand Standard

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

Australian/New Zealand Standard

49469-IND: Mumbai Metro Rail Investment Project. 12 June 2018, 15:00 hours Indian Standard Time (IST)

TECHNICAL MANUAL. DISTRIBUTION STATEMENT A : Approved for public release; distribution is unlimite.

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

OPERATOR S MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET

A. General provisions and other electrical systems are specified in other Sections of Division 26.

B. All of the documents in this RFP form the Basis-of-Design for this project.

This document is a preview generated by EVS

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

PRODUCTION PERMIT/ CONCESSION FORM GUIDELINES

Solar Homes and Communities Plan Residential application for pre-approval

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

Guidelines on the Keeping of Records in Respect of Medicinal Products when Conducting a Retail Pharmacy Business

AMENDMENT OF SOLICITATION

Declaration of Classification ValiSpore Incubator Manual

Miscellaneous Publication

AS/NZS :2014. Single-use medical examination gloves AS/NZS :2014

Australia s National Guidelines and Procedures for Approving Participation in Joint Implementation Projects

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

Australian/New Zealand Standard

REQUESTING QUALIFICATIONS FOR PROFESSIONAL SERVICES

Pre-registration. e-portfolio

Clinical Coding Policy

Non Medical Prescribing Policy

NZQA Expiring unit standard version 3 Page 1 of 6

City of Puyallup City-Owned Fiber Infrastructure Evaluation Project

*PLEASE NOTE NEW SIZES TO ADVERTISING SPECS ON PAGE 5

TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTS)

RG 102 Accreditation for the Inspection of Non-public High Voltage Electrical Systems

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

PART II: GENERAL CONDITIONS APPLICCABLE TO GRANTS FROM THE NORWEGIAN MINISTRY OF FOREIGN AFFAIRS

Position description. Classification Registered Nurse Grade 3

Agreement. Between: The Research Foundation, Cerebral Palsy Alliance. And: (Name of Institution) Project: (Name of project)

Medication Management Policy and Procedures

REQUESTING QUALIFICATIONS FOR PROFESSIONAL DESIGN SERVICES

Frequently Asked Questions (FAQs) regarding ISO/IEC 17025:2017 and the transition of accreditation from the previous version of the Standard

ANCILLARY EQUIPMENT FOR: PERSONNEL TROOP PARACHUTE SYSTEM

PART V PROPOSAL REQUIREMENTS

MAGTFTC MCAGCC GUIDANCE FOR DD FORM 67 (FORM PROCESSING ACTION REQUEST )

ARMY TB

Level 2 NVQ Diploma in Heating and Ventilating - Ductwork Installation ( )

Interim Australian/New Zealand Standard

NOTE ON PERFORMANCE TESTING

MMRCL Recruitment Advertisement

Documents and Records Management ISO 14001:

Australian/New Zealand Standard

OH-58A/C AIRCRAFT PHASED MAINTENANCE CHECKLIST

Fiscal Year 2018 Competitive Funding Opportunity; Grants for Buses and Bus Facilities Infrastructure Investment Program

INFORMATION BULLETIN OPERATING PERMITS

Oracle. Human Capital Management Cloud Using Volunteering. Release 13 (update 18A)

Techstream ECU Flash Reprogramming Procedure

OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL FOR MULTIPLEXER SET AN/FCC-97 (NSN )

Medical Grade Power Strips

ARMY AH-64A HELICOPTER

Association of Mining and Exploration Companies (Inc)

Easylink to Square D Module

TRIP OF YALLOURN POWER STATION NO KV BUSBAR ON 6 DECEMBER 2015

CAP REGULATION 1-2 NATIONAL HEADQUARTERS CIVIL AIR PATROL 07 NOVEMBER 2016 CIVIL AIR PATROL STANDARDS PUBLICATIONS MANAGEMENT

COMPRESSED NATURAL GAS UTILITY TRUCK BODIES

TM &P TECHNICAL MANUAL INTRODUCTION 1-1 OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Proposal Form for Standards Development Projects. Version: 2.0 Issued: March 2010

Technical specifications for Interoperability (TSIs)

Item No. Description Part No.

SUP 08 Operational procedures for Medical Gas Pipeline Systems (MGPS) Unified procedures for use within NHS Scotland

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A

REPORT. Unit # 1, Street Surrey, British Columbia, V3W 4E6, Canada

FILING OF ANNUAL FINANCIAL STATEMENTS TO THE CIPC IN XBRL

Clinical Documentation

AS/NZS 1336:1997 AS/NZS

DEPARTMENT OF DEFENSE INTERFACE STANDARD BI-LEVEL IMAGE COMPRESSION FOR THE NATIONAL IMAGERY TRANSMISSION FORMAT STANDARD

OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING LASER: M83 (NSN ) FOR

GUIDELINES FOR THE USE OF ASSISTIVE TECHNOLOGY EQUIPMENT IN COMMUNITY INPATIENT UNITS

OPERATOR, ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS

NATIONAL PATIENT REPORTED OUTCOME MEASURES (PROMS) SUPPLIER ACCREDITATION PROCESS

Automated License Plate Reader (ALPR) System. City of Coquitlam. Request for Proposals RFP No Issue Date: January 25, 2017

The Director is the legally responsible person must manage the RTO s compliance with the Standards for RTO s 2015.

SOUTH AFRICAN NATIONAL STANDARD

REQUEST FOR PROPOSALS

CHESAPEAKE BAY BRIDGE AND TUNNEL DISTRICT PARALLEL THIMBLE SHOAL TUNNEL REQUEST FOR QUALIFICATIONS #PTST-15-1

TANZANIA CIVIL AVIATION AUTHORITY AERODROMES AND AIR NAVIGATION SERVICES. Foreword

Assessing Benefits from the Regional Rail Link Project. Independent assurance report to Parliament. May : 18

DMTF Standards Incubation Process

Document Title: Study Data SOP (CRFs and Source Data)

Machine Gun Barrel Research Records, Carnegie Institution of Washington Geophysical Laboratory Archives Washington, DC

Level 3 NVQ Diploma in Pharmacy Service Skills (QCF) ( )

CNAS-RC07. Rules for the Accreditation of Certification Bodies with Foreign Locations

Track Occupancy Authority

Smoke Control BACnet PTEC Unit Vent Controller. Control Applications. Product Description. Product Numbers

Public Address System Norwalk Public Schools REQUEST FOR PROPOSAL 1/16/15 Proposal Response Date:

Level 2 Award in Employment Responsibilities and Rights in Health, Social Care and Children and Young People's Settings ( )

Level 2 Award/Certificate/Diploma in Cleaning and Support Services Skills ( )

Transcription:

Engineering Specification Signalling L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION Version: 1

ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 Approval Name Position Signature Document Endorser Louisa Waymouth Manager Standards Approving Manager Phil Ellingworth Chief Engineer Amendment Record Approval Date Version Description 20/06/2018 1 Rebadge VRIOGS 012.7.33 Signal Identification and General Information. No change to the technical content. Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 2 of 133

ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 PREFACE This Specification replaces VRIOGS 012.7.33 Signal Identification and General Information. The contents of this Specification were prepared by the Victorian Rail Industry Operators Group (VRIOG). This VRIOG Standard has been rebadged as an MTM document due to the retirement of VRIOG Standards as of 30 th June 2018. This Specification will be managed under the Engineering Standards Development Procedure (L1-CHE-PRO-032). As documents are uncontrolled once printed, it is imperative to check the currency of the Document on The Depot or the MTM s Document Portal which is available externally at https://documentportal.metrotrains.com.au. All MTM Standards and Specifications are periodically reviewed, and new editions are published which incorporate learnings and Technical Notes (formerly known as Design Practice Notes). Technical Notes are issued between editions which correct any errors or ambiguities contained in an MTM Standard/Specifications. Standards and Specifications may also be withdrawn and/ or replaced. In the event of conflicts or discrepancies between different types of technical documents, refer to the order of precedence as defined in Chief Engineer s Guideline Engineering Standards Listing (L1-CHE-GDL-005). Note: Any clarification described in a Technical Note or Design Practice Note shall take precedence over the impacted clause or clauses in the associated MTM Standard/Specification. In the event a clause within a Standard/Specification is not achievable a waiver will need to be raised, please refer to the Engineering Waiver Procedure - L1-CHE-PRO-001. Note: MTM does not have the authority to grant waivers on any Standards/Specifications or clauses within a Standard/Specification which relate to Government Regulations or Legislation, e.g. Disability Discrimination Act. Referencing this document Clauses and subclauses of this document should be referenced using the following format style L1-CHE-XXX-YYY Clause Z.Z.Z. Referencing the VRIOGS document number is not required. Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 3 of 133

ENGINEERING SPECIFICATION SIGNAL IDENTIFICATION AND GENERAL INFORMATION L1-CHE-SPE-305 Version: 1 Effective from: 1 st July 2018 THIS PAGE IS INTENDED TO BE BLANK Approving Manager: Chief Engineer Approval Date: 20/06/2018 Next Review Date: 20/06/2021 PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 4 of 133

Victorian Rail Industry Operators Group Standards VRIOGS 012.7.33 Signal Equipment Identification and General Information Revision: Revision A Issue Date: 12/10/2009

ii VRIOGS 012.7.33 Revision A VRIOGS 012.7.33 Signal Equipment Identification and General Information Revision A Issue Date: 12/10/2009 APPROVAL STATUS APPROVER STATUS DATE QUALIFICATIONS Document Developer VRIOG Steering Committee Approved All Sections Accredited Rail Operator Metropolitan Train (Metro Trains Melbourne) Intrastate Train (V/Line) Interstate Train (ARTC) Tram (Yarra Trams) For any queries please contact vriogs@transport.vic.gov.au.

VRIOGS 012.7.33 Revision A iii PURPOSE OF THE STANDARD The Standard has been created through the collaboration of members of the Victorian Rail Industry Operators Group (VRIOG) for the purpose of establishing standards which, if implemented throughout the Victorian Rail Network, will facilitate the interoperability of infrastructure. The use of the Standard is not prescribed by law but, if adopted, conformity with the provisions of the Standard is mandatory in order that the purpose of the Standard be achieved. DISCLAIMER The Standard is published by the Director of Public Transport for information purposes only and does not amount to any kind of advice. Each person is responsible for making his or her own assessment of all such information and for verifying such information. The content of this publication is not a substitute for professional advice. The Director of Public Transport and VRIOG accept no liability for any loss or damage to any person, howsoever caused, for information contained in this publication, or any purported reliance thereon. COPYRIGHT STATEMENT Director of Public Transport 2005. This publication is copyright. No part may be reproduced by any process except in accordance with the provisions of the Copyright Act. Where information or material is so used, it should be used accurately and the Standard should be acknowledged as the source of the information.

iv VRIOGS 012.7.33 Revision A TABLE OF CONTENTS SECTION 1.0 CONVENTIONS... 1 SECTION 2.0 DEFINITIONS... 2 SECTION 3.0 SCOPE AND GENERAL... 3 3.1 Scope... 3 3.2... 3 3.3 Background... 3 SECTION 4.0 GENERAL... 4 SECTION 5.0 TRANSFORMERS... 5 SECTION 6.0 REFERENCE LIST VRI TO IRONCORE... 6 SECTION 7.0 REFERENCE LIST IRONCORE TO VRI... 9 SECTION 8.0 REFERENCE LIST SECONDARY VOLTAGE TO VRI... 10 SECTION 9.0 COMPONENT CIRCUITS AND PHOTOS... 13 SECTION 10.0 REFERENCES... 125

VRIOGS 012.7.33 Revision A 1 SECTION 1.0 CONVENTIONS 1) Words or phrases that appear capitalised out of context are defined within the Definitions section of this VRIOG Standard. 2) The word Shall is to be understood as mandatory. 3) The word Should is to be understood as non-mandatory i.e. advisory or recommended. 4) Uncontrolled Standards may not be referenced within the VRIOG Standards. These include former PTC Standards, Franchisee Standards, Franchisee Subcontractor Standards and Infrastructure Lessee Standards. 5) Controlled Standards, including Australian Standards and other VRIOG Standards, may be referenced but only if: The referenced item can not be adequately explained with an amount of text that could not reasonably be inserted into the body of the Standard. The reader is not referenced to another Controlled Standard necessary for the item to be adequately explained i.e. one document link only. The referenced document is a Figure or table and could not reasonably be included in the appendices of the Standard. 6) The format employed in the VRIOG Standards is compatible with Australian Standards, and will be used from this point on. 7) The numbering system for the VRIOG Standards is chronologically sequential from the point of introduction, and is not based on any form of interpretive system. 8) The VRIOG Standards contain engineering information necessary to operate a safe Railway. VRIOG Standards will not contain any information that can be construed as a work instruction, procedure, process or protocol. This information forms the basis of each individual entity s Safety Accreditation Certification, and, as such, is outside the scope of VRIOG Standards.

2 VRIOGS 012.7.33 Revision A SECTION 2.0 DEFINITIONS Terminology used and/or applied in this Standard is defined as follows:- ARTC Terminology Accredited Rail Operator (ARO) DMS DOT Infrastructure Manager Ironcore PTC PTD VR Definition Australian Rail Track Corporation A Rail Infrastructure Manager or Rolling Stock Operator who is accredited under Part 5 of the Rail Safety Act 2006. VicTrack Drawing Management System Department of Transport The Manager of the rail infrastructure system and owner of the associated rail safety management systems A Manufacturer of power supplies and battery chargers, etc Public Transport Corporation The Public Transport Division of the Department of Transport Victorian Railways VRI Victorian Railways Industry VRIOGS The Victorian Rail Industry Operators Group comprising the following members: VicTrack V/Line Passenger Metro Trains Melbourne Yarra Trams Australian Rail Track Corporation (ARTC) Public Transport Division (PTD) of the Department of Transport (DOT) Table 1 - Terminology

VRIOGS 012.7.33 Revision A 3 SECTION 3.0 SCOPE AND GENERAL 3.1 Scope This Standard captures the general specifications and identifying photos of various signalling equipment items; such as power supplies, transformers, battery chargers, rectifiers, etc for use within the Victorian Railway Network. It also contains a number of conversion charts between part numbers for Iron Core type signalling power supplies, battery chargers, etc to that of the Victorian Rail Industry part numbers. This Standard is intended to be dynamic, in that it will continually be updated to capture signalling equipment, by those within the Industry. 3.2 This is the Standard that is used as within the Victorian Railway Network to capture signal equipment such as transformers, power supplies, battery chargers, etc. This Standard should be read in conjunction with all other VRIOGS signal equipment technical specifications, and reference also made to the ARO s type approved signal equipment list. 3.3 Background This Standard replaces all previous versions of Railway Signal Equipment Technical General Specifications, such as and not limited to; Victorian Railways Signal Equipment Technical General Specifications Public Transport Corporation (PTC) Signal Equipment Technical General Specifications Thiess Infraco Signal Equipment Technical General Specifications

4 VRIOGS 012.7.33 Revision A SECTION 4.0 GENERAL Please note that the following drawings have been created by the author for inclusion within this document. They were not part of the original A2 size B drawings of the Victorian Railways 7B1521 to 12B1521 1B1995 to 6B1995 9B1995, all B1996 9B1997 to 12B1997 It should be noted that within the specification there are a number of items which are OBSOLETE and as such have been replaced by other listed items, from within this specification, and are captured within this specification purely for maintenance functions to identify the equipment and its purpose. There are also items that have been SUPERSEDED by other items, and these are also listed, as also their replacements This specification should be read in conjunction with all other VRIOGS signal equipment technical specifications, and reference also made to the ARO s type approved signal equipment list. While every endeavour has been made to ensure the information contained within this document is accurate and up to date errors may have occurred. Please provide any corrections, additional photos or comments to the DOT Manager of Standards.

VRIOGS 012.7.33 Revision A 5 SECTION 5.0 TRANSFORMERS 1. In general all transformers shall be of single phase, double wound; metal clad, natural air cooling type, with rated output specified, to operate from single phase 25 or 50 hertz supply voltage with a temperature rise not exceeding 55 C. 2. Transformers shall be designed for indoor use and wall mounting. 3. The exterior of transformers for use on 50-hertz supply shall be coloured yellow. 4. All winding ends and tapings shall be brought to easily accessible terminals. 5. The positive terminals of the same instantaneous polarity shall be marked by red disc. 6. A label giving Manufacture s name and serial number of transformer and rating plate shall be securely fitted to the front (preferably) of each transformer.

6 VRIOGS 012.7.33 Revision A SECTION 6.0 REFERENCE LIST VRI TO IRONCORE VRI No. Ironcore Voltage Rating Freq 1B 954 T1 / 451 110 / 6.5-8.25V 16VA 25Hz 2B 954 T6 /1950 110 / 37-110V 25VA 25Hz 3B 954 T6 / 1035 110 / 37-110V 75VA 25Hz 4B 954 240 / 3-18V 25VA 50Hz 5B 954 T1 / 412 110 / 3-18V 25VA 25Hz 6B 954 Obsolete see 7B954 7B 954 T6 / 752 110 / 6-6V 75VA 25Hz 8B 954 T1 / 528 110 / 110-110V 30VA 25Hz 9B 954 T6 / 862 110 / 110-110V 150VA 25Hz 10B 954 Obsolete see 7B1390 11B 954 T6 / 871 110 / 12-108V 25VA 25Hz 12B 954 T6 / 660 110 / 230V 150VA 50Hz 1B 1126 T5 / 241 110 / 6-6V 5VA 25Hz 2B 1126 T6 / 1410 110 / 21-36V 50VA 25Hz 3B 1126 T6 / 750 110 / 6-6V 100VA 50Hz 4B 1126 T5 / 326 1 / 1-6V 1VA 25Hz 5B 1126 Obsolete see 7B1390 6B 1126 T5 / 447 110 / 6.5-8.25V 20VA 50Hz 7B 1126 T3 / 201 110 / 3-18V 25VA 50Hz 8B 1126 T1 / 452 110 / 7-8.5V 85VA 50Hz 9B 1126 T9 / 186 230 / 110-125V 500VA 50Hz 10B 1126 T3 / 199 110 / 110V 25VA 50Hz 11B 1126 110 / 17-18.5V 37VA 50Hz 12B 1126 T5 / 199 Obsolete see 1B1126 1B 1390 T6 / 1102 110 / 3-18V 90VA 50Hz 2B 1390 T6 / 869 110 / 10-12.5V 125VA 50Hz 3B 1390 110 / 3-1 8V 90VA 25Hz 4B 1390 110 / 6-11.5V 25VA 25Hz 5B 1390 110 / 30-34V 85VA 25Hz 6B 1390 T1 / 1356 110 / 11-12V 25VA 50Hz 7B 1390 T3 / 258 110 / 110V 5VA 25Hz 8B 1390 ST 1448 230 / 110V 1.5kVA 50Hz 9B 1390 ST1340 230 / 110V 3kVA 50Hz 10B 1390 T1 / 1356 110 / 9-12V 30VA 25Hz 11B 1390 T1 / 1354 Superseded by 10B1390 12B 1390 T1 / 1226 110 / 3-18V 40VA 50Hz 1B 1521 T10 / 663 230 / 110V 750VA 50Hz 2B 1521 110 / 110V 2kVA 50Hz 3B 1521 T1 / 1226 110 / 3-18V 40VA 50Hz 4B 1521 T10 / 29 440 / 110V 1kVA 50Hz 5B 1521 440 / 110V 4kVA 50Hz 6B 1521 T3 / 253 110 / 120V 30VA 50Hz 7B 1521 T14 / 156 440 / 125V 2kVA 50Hz 8B 1521 T14 / 156 440 / 125V 2kVA 50Hz 9B 1521 T14 / 207 440 / 125V 3kVA 50Hz

VRIOGS 012.7.33 Revision A 7 VRI No. Ironcore Voltage Rating Freq 10B 1521 T14 / 172 460 / 230V 3kVA 50Hz 11B 1521 T14 / 174 240 / 440V 4kVA 50Hz 12B 1521 T14 / 208 240 / 440V 5kVA 50Hz 1B 1995 T9 / 1648M 110 / 12Vdc 8A 50Hz 2B 1995 T9 / 1649M 110 / 24Vdc 8A 50Hz 3B 1995 HS1 12Vdc 4B 1995 Voltage Sensing Relay 5B 1995 T3 / 293 110 / 2Vdc 3A 5B 1995 T9 / 1645 110 / 50Vdc 500VA 50Hz 6B 1995 ST1849 110 / 24Vdc 10A 50Hz 7B 1995 T14 / 212 240 / 110V 3kVA 50Hz 8B 1995 230 / 460V 3kVA 25Hz 9B 1995 T5 / 38 110 / 50Vdc 500VA 25Hz 10B 1995 T14 / 135 240 / 110V 5kVA 11B 1995 ST 791 240 / 110V 6kVA 12B 1995 na 1B 1996 Current Sensor 30mA 2B 1996 Track Rectifier NT Type 3B 1996 Track rectifier BT Type 4B 1996 na 5B 1996 T9 / 1440M 110 / 15Vdc 25A 6B 1996 110 / 15.7Vdc 7.5A 50Hz 7B 1996 na 8B 1996 Current Sensor 30mA 9B 1996 24Vdc 6A 10B 1996 T5 / 467 240Vac 200mA 11B 1996 110 / 24Vdc 20A 12B 1996 24Vdc 6A 1B 1997 Contact Protection Unit 3A 2B 1997 Slow Release Unit 3B 1997 T6 / 2516 110 / 3-18Vdc 5A 90VA 4B 1997 Obsolete see 4B1995 5B 1997 T3 / 241 12Vdc 1.5A 6B 1997 T3 / 249 50Vdc 0.2A 7B 1997 T1 / 1257 110 / 4.2Vdc 50VA 25Hz 8B 1997 T1 / 1269 110 / 12Vdc 50VA 50Hz 9B 1997 T9 / 159 110 / 50Vdc 250VA 25Hz 10B 1997 Negative Regulator 0.5A 11B 1997 Approach Indicator 12B 1997 110 / 24Vdc 3A 25Hz 1B 1998 T1 / 1355 110 / 18Vdc 2A 25VA 50Hz 2B 1998 2, 4, 6, 10, 12V L.E.D Unit 3B 1998 2, 4, 6, 10, 12V L.E.D Unit 4B 1998 T5 / 489 110 / 50Vdc 10VA 25Hz 5B 1998 Obsolete see 9B1998 2A 6B 1998 T1 / 1200 110 / 6Vdc 45VA 25Hz 7B 1998 T9 / 1389 110 / 24Vdc 10A 260VA 8B 1998 2, 4, 6, 10, 12V L.E.D Unit 9B 1998 5-15Vdc Flasher Card 2A

8 VRIOGS 012.7.33 Revision A VRI No. Ironcore Voltage Rating Freq 10B 1998 110 / 24Vdc 11B 1998 2, 4, 6, 10, 12V L.E.D Unit 12B 1998 ST1405 110 / 50Vdc 1kVA 25Hz 1B 1999 T9 / 29 110 / 12Vdc 250VA 25Hz 2B 1999 DD07 12Vdc / 50Vdc 50VA 3B 1999 T0 / 34 10Vdc / 50Vdc 4B 1999 T5 / 441 110 / 6Vdc 5VA 25Hz 5B 1999 Slow Release Unit 1A 6B 1999 SF1 12Vdc 16A 7B 1999 na 8B 1999 T1 / 1008 110 / 50Vdc 9B 1999 T6 / 1860 110 / 50Vdc 50VA 25Hz 10B 1999 Obsolete see 12B1997 3A 11B 1999 Slow Release Unit 12B 1999 Bridge Rectifier 4A 1B 2000 T5 / 38 110 / 50Vdc 10VA 25Hz 2B 2000 110 / 12-24Vdc 10VA 50Hz 3B 2000 T5 / 73 110 / 12Vdc 6VA 25Hz 4B 2000 T3 / 59A 12Vdc / 6-6 - 6Vac 1.5A 27VA 5B 2000 T6 / 1552 12Vdc / 6-6 - 6Vac 1.5A 6B 2000 T9 / 858 110 / 12Vdc 20A 400VA 25Hz 7B 2000 9-12Vdc TDU 8B 2000 50Vdc TDU 9B 2000 50Vdc 2TDU 3VA 10B 2000 Obsolete see 6B1999 16A 11B 2000 T10 / 368 110 / 21Vdc 17A 400VA 25Hz 11B 2000M T10 / 1071 110 / 21Vdc (16Vdc) 25A 50Hz 12B 2000 T9 / 151 250 / 50Vdc 5A Table 2 - Cross reference list -VRI to Ironcore

VRIOGS 012.7.33 Revision A 9 SECTION 7.0 REFERENCE LIST IRONCORE TO VRI Ironcore VRI No. Ironcore VRI No. Ironcore VRI No. DD O7 2B 1999 T5 489 4B 1998 T10 29 4B 1521 T5 594 T10 368 11B 2000 HS 1 3B 1995 T5 38 9B 1995 T10 609 6B 2000 T5 38 1B 2000 T10 663 1B 1521 SF 1 6B 1999 T5 73 3B 2000 T10 668 9B 1126 T5 199 12B 1126 T10 1071 11B 2000M ST 251 T5 241 1B 1126 ST 791 11B 1995 T5 441 4B 1999 T13 16 8B 1390 ST 1114 T5 326 4B 1126 T13 38 ST 1115 T5 447 6B 1126 ST 1200 6B 1998 T5 467 10B 1996 T14 135 10B 1995 ST 1340 9B 1390 T14 156 7B 1521 ST 1405 12B 1998 T6 660 12B 954 T14 156 8B 1521 ST 1448 8B 1390 T6 663 9B 1999 T14 172 10B 1521 ST 1849 6B 1995 T6 750 3B 1126 T14 174 11B 1521 T6 752 7B 954 T14 207 9B 1521 T0 34 3B 1999 T6 862 9B 954 T14 208 12B 1521 T6 869 2B 1390 T14 212 7B 1995 T1 412 5B 954 T6 871 11B 954 T1 451 1B 954 T6 1035 3B 954 T15 142 T1 452 8B 1126 T6 1102 1B 1390 T1 457 1B 954 T6 1228 3B 954 T16 39 T1 528 8B 954 T6 1410 2B 1126 T1 1008 8B 1999 T6 1552 5B 2000 TG 445 T1 1200 6B 1998 T6 1850 9B 1999 T1 1226 3B 1521 T6 1860 9B 1999 T1 1226 12B 1390 T6 1950 2B 954 T1 1257 7B 1997 T6 2516 3B 1997 T1 1269 8B 1997 T1 1354 11B 1390 T9 29 1B 1999 T1 1355 1B 1998 T9 151 12B 2000 T1 1356 10B 1390 T9 159 12B 2000 T1 1356 6B 1390 T9 159 9B 1997 T9 186 9B 1126 T3 59 4B 2000 T9 558 6B 2000 T3 59A 4B 2000 T9 1645 5B 1995 T3 199 10B 1126 T9 1648M 1B 1995 T3 201 7B 1126 T9 1649M 2B 1995 T3 241 5B 1997 T9 852 6B 2000 T3 249 6B 1997 T9 858 6B 2000 T3 253 6B 1521 T9 1389 7B 1998 T3 258 7B 1390 T9 1440M 5B 1996 T3 293 5B 1995 Table 3 - Cross reference list Ironcore to VRI

10 VRIOGS 012.7.33 Revision A SECTION 8.0 REFERENCE LIST SECONDARY VOLTAGE TO VRI Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 3-18Vdc 3B 1997 110V 90VA 25Hz 4.2Vdc 7B 1997 110V 50VA 25Hz 6Vdc 4B 1999 110V 5VA 25Hz 6Vdc 6B 1998 110V 45VA 25Hz 12Vdc 3B 2000 110V 6VA 25Hz 12Vdc 8B 1997 110V 50VA 50Hz 12Vdc 1B 1995 110V 100VA 50Hz 12Vdc 1B 1999 110V 250VA 25Hz 12Vdc 6B 2000 110V 400VA 25Hz 12-24Vdc 2B 2000 110V 10VA 50Hz 15Vdc 5B 1996 110V 25A 50Hz 15.7Vdc 6B 1996 110V 7.5A 50Hz 18Vdc 1B 1998 110V 25VA 50Hz 21Vdc 11B 2000 110V 17A 25Hz 21Vdc 11B 2000M 110V 25A 50Hz 24Vdc 9B 1996 24Vdc 6A 25Hz 24Vdc 12B 1996 24Vdc 6A 25Hz 24Vdc 12B 1997 110V 3A 25Hz 24Vdc 10B 1999 110V 3A 24Vdc 2B 1995 110V 8A 50Hz 24Vdc 6B 1995 110V 10A 50Hz 24Vdc 11B 1996 110V 20A 50Hz 24Vdc 7B 1998 110V 260VA 50Hz 24Vdc 10B 1998 110V 450VA 50Hz 50Vdc 2B 1999 12Vdc 50VA 50Vdc 4B 1998 110V 10VA 25Hz 50Vdc 1B 2000 110V 10VA 25Hz 50Vdc 8B 1999 110V 50VA 50Hz 50Vdc 9B 1999 110V 50VA 25Hz 50Vdc 12B 2000 110V 250VA 25Hz 50Vdc 9B 1997 110V 250VA 25Hz 50Vdc 5B 1995 110V 500VA 50Hz 50Vdc 9B 1995 110V 500VA 25Hz

VRIOGS 012.7.33 Revision A 11 Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 50Vdc 12B 1998 110V 1kVA 25Hz 3-18V 5B 954 110V 25VA 25Hz 3-18V 7B 1126 110V 25VA 50Hz 3-18V 12B 1390 110V 40VA 50Hz 3-18V 3B 1521 110V 40VA 50Hz 3-18V 1B 1390 110V 90VA 50Hz 3-18V 3B 1390 110V 90VA 25Hz 3-18V 4B 954 240V 25VA 50Hz 6V 4B 2000 12Vdc 1.5A 50Hz 6V 5B 2000 12Vdc 1.5A 50Hz 6-6V 1B 1126 110V 5VA 25Hz 6-6V 12B 1126 110V 5VA 50Hz 6-6V 6B 954 110V 50VA 25Hz 6-6V 7B 954 110V 75VA 25Hz 6-6V 3B 1126 110V 100VA 50Hz 6.5-8.25V 1B 954 110V 16VA 25Hz 6.5-8.25V 6B 1126 110V 20VA 50Hz 6-11.5V 4B 1390 110V 25VA 25Hz 7-8.5V 8B 1126 110V 85VA 50Hz 9-12V 10B 1390 110V 30VA 25Hz 9-12V 11B 1390 110V 50Hz 10-12.5V 2B 1390 110V 125VA 50Hz 11-12V 6B 1390 110V 25VA 50Hz 12-108V 11B 954 110V 25VA 25Hz 17-18.5V 11B 1126 110V 37VA 50Hz 21-36V 2B 1126 110V 50VA 25Hz 24V 3B 1999 10Vdc 30-34V 5B 1390 110V 85VA 25Hz 37-110 2B 954 110V 25VA 25Hz 37-110 3B 954 110V 75VA 25Hz 110V 7B 1390 110V 5VA 25Hz 110V 10B 1126 110V 25VA 50Hz 110-110V 8B 954 110V 30VA 25Hz 110-110V 9B 954 110V 150VA 25Hz

12 VRIOGS 012.7.33 Revision A Secondary Voltage VRI No. Primary Voltage Ampere Rating Frequency 110V 2B 1521 110V 2kVA 50Hz 110-125V 9B 1126 230V 500VA 50Hz 110V 1B 1521 230V 750VA 50Hz 110V 8B 1390 230V 1.5kVA 50Hz 110V 9B 1390 230V 3kVA 50Hz 110V 7B 1995 240V 3kVA 50Hz 110V 10B 1995 240V 5kVA 110V 11B 1995 240V 6kVA 110V 4B 1521 440V 1kVA 50Hz 110V 5B 1521 440V 4kVA 50Hz 120V 6B 1521 110V 30VA 50Hz 125V 7B 1521 440V 2kVA 50Hz 125V 8B 1521 440V 2kVA 50Hz 125V 9B 1521 440V 3kVA 50Hz 230V 12B 954 110V 150VA 50Hz 230V 10B 1521 460V 3kVA 50Hz 240V 10B 1996 240V 200mA 250V 10B 954 110V 250V 5B 1126 110V 440V 11B 1521 240V 4kVA 50Hz 440V 12B 1521 240V 5kVA 50Hz 460V 8B 1995 230V 3kVA 25Hz Table 4 - Cross reference list Secondary Voltage

VRIOGS 012.7.33 Revision A 13 SECTION 9.0 COMPONENT CIRCUITS AND PHOTOS Identifying Name 1B 954 Searchlight Signal INSERT PHOTO

14 VRIOGS 012.7.33 Revision A Identifying Name 2B 954 Light Signal Dimming INSERT PHOTO

VRIOGS 012.7.33 Revision A 15 Identifying Name 3B 954 Light Signal Dimming

16 VRIOGS 012.7.33 Revision A Identifying Name 4B 954 Trickle Charging INSERT PHOTO

VRIOGS 012.7.33 Revision A 17 Identifying Name 5B 954 Trickle Charging

18 VRIOGS 012.7.33 Revision A Identifying Name 7B 954 Now Obsolete and see 7B954 Track Feed INSERT PHOTO

VRIOGS 012.7.33 Revision A 19 Identifying Name 7B 954 Track Feed

20 VRIOGS 012.7.33 Revision A Identifying Name 8 B 954 Pole Changing

VRIOGS 012.7.33 Revision A 21 Identifying Name 9B 954 Pole Changing INSERT PHOTO

22 VRIOGS 012.7.33 Revision A Identifying Name 10B 954 Now Obsolete and see 7B1390 Point Detection

VRIOGS 012.7.33 Revision A 23 Identifying Name 11B 954 Bell Ringing

24 VRIOGS 012.7.33 Revision A Identifying Name 12B 954 240 volt mains INSERT PHOTO

VRIOGS 012.7.33 Revision A 25 Identifying Name 1B 1126 Indication Light

26 VRIOGS 012.7.33 Revision A Identifying Name 2B 1126 Transformer

VRIOGS 012.7.33 Revision A 27 Identifying Name 3B 1126 Transformer

28 VRIOGS 012.7.33 Revision A Identifying Name 4B 1126 Track Relay Shielding

VRIOGS 012.7.33 Revision A 29 Identifying Name 5B 1126 Now Obsolete and see 7B 1390 Point Detection

30 VRIOGS 012.7.33 Revision A Identifying Name 6B 1126 Searchlight Signal

VRIOGS 012.7.33 Revision A 31 Identifying Name 7B 1126 Trickle Charging

32 VRIOGS 012.7.33 Revision A Identifying Name 8B 1126 Flashing Light Signal Lamps INSERT PHOTO

VRIOGS 012.7.33 Revision A 33 Identifying Name 9B 1126 230 volt mains

34 VRIOGS 012.7.33 Revision A Identifying Name 10B 1126 Line Circuit Isolations

VRIOGS 012.7.33 Revision A 35 Identifying Name 11B 1126 Searchlight Signal

36 VRIOGS 012.7.33 Revision A Identifying Name 12B 1126 Now Obsolete and see 1B 1126 Indication Light

VRIOGS 012.7.33 Revision A 37 Identifying Name 1B 1390 Battery Charging INSERT PHOTO

38 VRIOGS 012.7.33 Revision A Identifying Name 2B 1390 Flashing Lights INSERT PHOTO

VRIOGS 012.7.33 Revision A 39 Identifying Name 3B 1390 Battery Charging INSERT PHOTO

40 VRIOGS 012.7.33 Revision A Identifying Name 4B 1390 Colour Light Signal

VRIOGS 012.7.33 Revision A 41 Identifying Name 5B 1390 Searchlight Signal

42 VRIOGS 012.7.33 Revision A Identifying Name 6B 1390 Searchlight Signal

VRIOGS 012.7.33 Revision A 43 Identifying Name 7B 1390 Point Detection

44 VRIOGS 012.7.33 Revision A Identifying Name 8B 1390 230 volt mains

VRIOGS 012.7.33 Revision A 45 Identifying Name 9B 1390 230 volt mains

46 VRIOGS 012.7.33 Revision A Identifying Name 10B 1390 Colour light signal dimming INSERT PHOTO

VRIOGS 012.7.33 Revision A 47 Identifying Name 11B 1390 Superseded by 10B 1390 Colour light signal

48 VRIOGS 012.7.33 Revision A Identifying Name 12B 1390 Battery Charging

VRIOGS 012.7.33 Revision A 49 Identifying Name 1B 1521 240 volt mains

50 VRIOGS 012.7.33 Revision A Identifying Name 2B 1521 Mains Isolating INSERT PHOTO

VRIOGS 012.7.33 Revision A 51 Identifying Name 3B 1521 Trickle Charging INSERT PHOTO

52 VRIOGS 012.7.33 Revision A Identifying Name 4B 1521 440 volt mains

VRIOGS 012.7.33 Revision A 53 Identifying Name 5B 1521 440 volt mains INSERT PHOTO

54 VRIOGS 012.7.33 Revision A Identifying Name 6B 1521 Line Isolating

VRIOGS 012.7.33 Revision A 55 Identifying Name 7B 1521 440 volt mains INSERT PHOTO

56 VRIOGS 012.7.33 Revision A Identifying Name 8B 1521 440 volt mains INSERT PHOTO

VRIOGS 012.7.33 Revision A 57 Identifying Name 9B 1521 440 volt mains INSERT PHOTO

58 VRIOGS 012.7.33 Revision A Identifying Name 10B 1521 440 volt mains INSERT PHOTO

VRIOGS 012.7.33 Revision A 59 Identifying Name 11B 1521 440 volt mains INSERT PHOTO

60 VRIOGS 012.7.33 Revision A Identifying Name 12B 1521 440 volt mains INSERT PHOTO

VRIOGS 012.7.33 Revision A 61 Identifying Name 1B 1995 Battery Charger

62 VRIOGS 012.7.33 Revision A Identifying Name 2B 1995 Battery Charger

VRIOGS 012.7.33 Revision A 63 Identifying Name 3B 1995 Healthy State Indicator

64 VRIOGS 012.7.33 Revision A Identifying Name 4B 1995 DC voltage sensing relay INSERT CIRCUIT

VRIOGS 012.7.33 Revision A 65 Identifying Name 5B 1995 Transformer Rectifier INSERT PHOTO

66 VRIOGS 012.7.33 Revision A Identifying Name 6B 1995 Transformer Rectifier

VRIOGS 012.7.33 Revision A 67 Identifying Name 9B 1995 Transformer Rectifier-Slugged

68 VRIOGS 012.7.33 Revision A Identifying Name 1B 1996 Current Sensor INSERT PHOTO

VRIOGS 012.7.33 Revision A 69 Identifying Name 2B 1996 Track Rectifier-NT

70 VRIOGS 012.7.33 Revision A Identifying Name 3B 1996 Track Rectifier-BT

VRIOGS 012.7.33 Revision A 71 Identifying Name 5B 1996 Battery Charger INSERT CIRCUIT

72 VRIOGS 012.7.33 Revision A Identifying Name 8B 1996 Current Sensor INSERT PHOTO

VRIOGS 012.7.33 Revision A 73 Identifying Name 9B 1996 Battery Charger INSERT CIRCUIT

74 VRIOGS 012.7.33 Revision A Identifying Name 10B 1996 Constant Current Source

VRIOGS 012.7.33 Revision A 75 Identifying Name 12B 1996 Rectifier Unit INSERT CIRCUIT

76 VRIOGS 012.7.33 Revision A Identifying Name 1B 1997 Contact Protection Unit

VRIOGS 012.7.33 Revision A 77 Identifying Name 2B 1997 Slow Release Unit INSERT PHOTO

78 VRIOGS 012.7.33 Revision A Identifying Name 3B 1997 Trickle Charger INSERT PHOTO

VRIOGS 012.7.33 Revision A 79 Identifying Name 4B 1997 DC Power Off Relay and Tone Unit

80 VRIOGS 012.7.33 Revision A Identifying Name 5B 1997 Line Surge Suppression Unit INSERT PHOTO

VRIOGS 012.7.33 Revision A 81 Identifying Name 6B 1997 Line Surge Suppression Unit INSERT PHOTO

82 VRIOGS 012.7.33 Revision A Identifying Name 7B 1997 Track Feed Unit

VRIOGS 012.7.33 Revision A 83 Identifying Name 8B 1997 Transformer Rectifier

84 VRIOGS 012.7.33 Revision A Identifying Name 9B 1997 Transformer Rectifier

VRIOGS 012.7.33 Revision A 85 Identifying Name 10B 1997 Negative Regulator

86 VRIOGS 012.7.33 Revision A Identifying Name 11B 1997 Approach Indicator

VRIOGS 012.7.33 Revision A 87 Identifying Name 12B 1997 Stabilised Power Supply CSEE Track Circuit

88 VRIOGS 012.7.33 Revision A Identifying Name 1B 1998 Battery Charger

VRIOGS 012.7.33 Revision A 89 Identifying Name 2B 1998 LED Indicator Unit

90 VRIOGS 012.7.33 Revision A Identifying Name 3B 1998 LED Signal Repeater

VRIOGS 012.7.33 Revision A 91 Identifying Name 4B 1998 Reactive Transformer Rectifier

92 VRIOGS 012.7.33 Revision A Identifying Name 5B 1998 Superseded by 9B 1998 Flasher Card

VRIOGS 012.7.33 Revision A 93 Identifying Name 6B 1998 DC Supply Unit

94 VRIOGS 012.7.33 Revision A Identifying Name 7B 1998 DC Filtered Power Supply Unit

VRIOGS 012.7.33 Revision A 95 Identifying Name 8B 1998 LED Indicator Signal

96 VRIOGS 012.7.33 Revision A Identifying Name 9B 1998 Flasher Card

VRIOGS 012.7.33 Revision A 97 Identifying Name 10B 1998 DC Filtered Power Supply Unit

98 VRIOGS 012.7.33 Revision A Identifying Name 11B 1998 LED Indicator Points

VRIOGS 012.7.33 Revision A 99 Identifying Name 12B 1998 DC Smoother Power Supply

100 VRIOGS 012.7.33 Revision A Identifying Name 1B 1999 Transformer Rectifier

VRIOGS 012.7.33 Revision A 101 Identifying Name 2B 1999 DC-DC Converter

102 VRIOGS 012.7.33 Revision A Identifying Name 3B 1999 Transistorised Inverter

VRIOGS 012.7.33 Revision A 103 Identifying Name 4B 1999 Track Feed Unit

104 VRIOGS 012.7.33 Revision A Identifying Name 5B 1999 Slow Release Unit for MSRA Relay

VRIOGS 012.7.33 Revision A 105 Identifying Name 6B 1999 Static Flasher Unit

106 VRIOGS 012.7.33 Revision A Identifying Name 7B 1999 Terminating Junction for unused 1B2000 Unit

VRIOGS 012.7.33 Revision A 107 Identifying Name 8B 1999 Now Obsolete and see 9B 1999 Transformer Rectifier

108 VRIOGS 012.7.33 Revision A Identifying Name 9B 1999 Transformer Rectifier

VRIOGS 012.7.33 Revision A 109 Identifying Name 10B 1999 Transformer Rectifier

110 VRIOGS 012.7.33 Revision A Identifying Name 11B 1999 Slow Release Unit for 2-MBA relays

VRIOGS 012.7.33 Revision A 111 Identifying Name 12B 1999 Bridge Rectifier

112 VRIOGS 012.7.33 Revision A Identifying Name 1B 2000 Transformer Rectifier

VRIOGS 012.7.33 Revision A 113 Identifying Name 2B 2000 Transformer Rectifier INSERT PHOTO

114 VRIOGS 012.7.33 Revision A Identifying Name 3B 2000 Transformer Rectifier

VRIOGS 012.7.33 Revision A 115 Identifying Name 4B 2000 Transistorised Inverter

116 VRIOGS 012.7.33 Revision A Identifying Name 5B 2000 Transistorised Inverter

VRIOGS 012.7.33 Revision A 117 Identifying Name 6B 2000 Battery Charger

118 VRIOGS 012.7.33 Revision A Identifying Name 7B 2000 Time Delay Unit INSERT PHOTO

VRIOGS 012.7.33 Revision A 119 Identifying Name 8B 2000 Time Delay Unit INSERT PHOTO

120 VRIOGS 012.7.33 Revision A Identifying Name 9B 2000 Twin Time Delay Unit

VRIOGS 012.7.33 Revision A 121 Identifying Name 10B 2000 Static Flasher Unit

122 VRIOGS 012.7.33 Revision A Identifying Name 11B 2000 Transformer Rectifier for Boom Barriers

VRIOGS 012.7.33 Revision A 123 Identifying Name 11B 2000 M Heavy Duty Transformer Rectifier for Boom Barriers

124 VRIOGS 012.7.33 Revision A Identifying Name 12B 2000 Transformer Rectifier

VRIOGS 012.7.33 Revision A 125 SECTION 10.0 REFERENCES 1. ARO type approved signal equipment list