Health & Safety Policy and Procedures Manual SECTION 31 CADMIUM

Similar documents
Great Western Painting Arsenic

A Summary of Cal/OSHA s Lead in Construction Standard Title 8 CCR Section

(b) Definitions. (d) Exposure Assessment Exposure assessment must be performed in all workplaces where employees may be exposed to lead.

Formaldehyde Exposure Control Policy

Formaldehyde Exposure Control Plan

BLOODBORNE PATHOGENS

Formaldehyde Program. For Compliance with Federal and State Regulated Carcinogen Regulations

SANDBLASTING CONTROL PLAN

CHEMICAL HYGIENE PLAN ENVIRONMENTAL HEALTH AND SAFETY 72 ONYX BRIDGE

RESPIRATORY PROTECTION PROGRAM

CHEMICAL HYGIENE PLAN

BLOODBORNE PATHOGENS EXPOSURE PREVENTION POLICY AND PROCEDURE BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

VP, Facilities and Construction Management

University of Illinois at Urbana-Champaign Facilities & Services Division of Safety and Compliance. Lead Program. Last Updated October 2012

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

CHEMICAL HYGIENE PLAN

Bloodborne Pathogens & Exposure Control Plan

NORTH CAROLINA A&T STATE UNIVERSITY Chemical Hygiene Plan

Respiratory Protection Program

Houston Controls, Inc Safety Management System

Hobart and William Smith Colleges. Personal Protective Equipment Program

DEPARTMENT OF LABOUR. Government Notice R February 2002 OCCUPATIONAL HEALTH AND SAFETY ACT, 1993 (ACT NO. 85 OF 1993) Lead Regulations, 2001

Appendix AX: B Occupational Exposure to Bloodborne Pathogens Exposure Control Plan

RMM # 500 Title: Designated Substances Control Program Approved: Karen Belaire Vice President, Administration

Health, Safety, Security and Environment

POLICY & PROCEDURES MEMORANDUM

Louisiana State University

"exposed" means exposed to lead while at the workplace and "exposure" has a corresponding meaning;

Shawnee State University

Environmental Health and Safety Department & Chemical Hygiene. Respiratory Protection Program

West Virginia University

Access to the laboratory is restricted when work is being conducted; and

Maintain Food Safety when Storing, Holding and Serving Food Level: 2 Credit value: 4 GLH: 31 TQT: 40

The City of Carson RESPIRATORY PROTECTION PROGRAM PLAN

[Type here] RESPIRATORY PROTECTION PROGRAM

Controlling Office: Director of Clinical Services Effective Date: May 1, Applies to CAMTS: n/a Last Review: January 1, 2018

Oak Grove School District Respiratory Protection Program

SECTION 6 PERSONAL PROTECTIVE EQUIPMENT (PPE)

Health and Safety in the lab. Seyed Hosseini SA Pathology Chemical Pathology

PPLGS SQA Code HD4V 04 Maintain food safety when storing, holding and serving food

RESPIRATORY PROTECTION

Level 2 Award in Health and Safety in Health and Social Care

RESEARCH LABORATORIES CONDUCTING HIV/HBV RESEARCH AND PRODUCTION

Environmental Standard Operating Procedure Originating Office: MCAS Yuma Environmental Department

University of Chattanooga Respiratory Protection Program. Areas Affected: Employees whose duties require the use of a respirator

Laboratory Safety Chemical Hygiene Plan (CHP)

Personal Hygiene. Author Date Dept. Approval Signature Date Q.A. Approval Signature Date

Laboratory Chemical Hygiene Plan -- Teaching Lab

POLICY. Asbestos removal OHSMS REQUIREMENTS FOR CLASS A ASBESTOS REMOVAL

Laboratory Chemical Hygiene Plan Research Lab

Respiratory Protection Plan

Biology 100, 101, 102, 105 Laboratory Safety Agreement

EXPOSURE CONTROL PLAN

Western Michigan University. Respiratory Protection Safety Policy

Respiratory Protection Program

Abu Dhabi Occupational Safety and Health System Framework (OSHAD-SF) Code of Practice

CORPORATE SAFETY MANUAL

DEPARTMENT OF LABOUR. Government Notice. R: February 2002 OCCUPATIONAL HEALTH AND SAFETY ACT, 1993 (ACT NO. 85 OF 1993)

i. Identifying work areas, processes or tasks that require workers to wear respirators, and evaluating hazards.

Rice University Exposure Control Plan

Control of Substances Hazardous to Health (COSHH) Procedure

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Personal Protective Equipment Program. Risk Management Services

Oregon Health & Science University Department of Surgery Standard Precautions Policy

MODULE 22: Contingency Planning and Emergency Response to Healthcare Waste Spills

Bloodborne Pathogens Cumru Township Fire Department 02/10/2011 Policy 10.5 Page: 1 of 7

This course was written for RN.ORG by an outside consultant and RN.ORG has rights for distribution but is not responsible for the contents.

Department of Environmental Health & Safety 11/ of 15

Bloodborne Pathogens Exposure Control Plan. Approved by The College at Brockport, Office of Environmental Health and Safety, February 2018

Michigan State University Department of Chemical Engineering and Materials Science (CHEMS) SAFETY Documents

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Requirements for Construction Site Welfare Facilities

ATTACHMENT B: TCSG Exposure Control Plan Model INTRODUCTION

Maintain food safety when preparing, storing and cooking food (2GEN3)

Regional School District No COMMUNICABLE AND INFECTIOUS DISEASES

Chapter 4 - Employee First Aid, Medical and Emergency Procedures

Employee First Aid, Medical and Emergency Procedures

I. Introduction. Definitions SP /16/2016. Chemistry Department Emergency Action Plan Spill Response

Accident Prevention Process

Bloodborne Pathogens. Goal. Objectives. Definitions. Background

Bloodborne Pathogens. Goal. Objectives. Background

Occupational Health and Safety Act, 1993 Asbestos Regulations, 2001

5. DEFINITIONS is a day care centre where child care educator will take care of children in place of their parents

COMPREHENSIVE SAFETY AND HEALTH PROGRAM TABLE OF CONTENTS

State of Maine Department of Transportation

Asbestos Management Plan

Respiratory Protection

Section 29 Brieser Construction SH&E Manual

Step 1A: Before entering patient room, be sure you have all the material ready and available:

BLOODBORNE PATHOGEN EXPOSURE CONTROL PLAN POLICY

320- HAZARD COMMUNICATION

VAMC Radiation Safety Refresher Training March 2011

OSHA Preparedness. Presented by: Dave Lall, CEO, DEMILEC (USA) LLC

Burn Intensive Care Unit

SALEM TOWNSHIP FIRE DEPARTMENT BLOODBORNE EXPOSURE CONTROL PLAN

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Infection Prevention, Control & Immunizations

Medical Surveillance and the New Cr(VI) Standard. Bruce A. Dalton, MD, MPH, FACOEM Medical Director, Workplace Group

CHEMICAL HYGIENE PLAN

Transcription:

SECTION 31 CADMIUM

1. CADMIUM A. Scope: This written compliance program applies to all Maul Electric, Inc employees or employees of Maul Electric, Inc subcontractors who may be exposed to cadmium at or above the prescribed action level of 2.5 micrograms per cubic meter of air averaged over any eight hour period. (2.5ug/m3). The permissible exposure limit (PEL) for cadmium 5 micrograms per cubic meter of air, averaged over any 8-hour period. (5ug/m3). B. Application: Maul Electric, Inc is not a user of cadmium. However, this material may be found at many of our client's facilities. Maul Electric, Inc should request copies of any plot plan or unit map indicating the location of regulated areas. All employees must be trained, as part of their initial site training, as to the hazards of cadmium exposure, signs, symptoms, necessary protective measures and the location of regulated areas. C. Exposure Monitoring: Air samples, taken by certified technicians and analyzed by approved Environmental Laboratories, must be taken from air that is representative of each employee's exposure to cadmium over an eight-hour period. 1. Exposure for monitoring purposes is defined as exposure that would occur if the employee were not using a respirator. 2. Full shift personal samples must be collected for each shift, each area and one sample for each classification in each work area. D. Initial Monitoring: Initial monitoring is required to accurately determine the employee's exposure to cadmium. All employees will be notified within 7 working days, in writing, of the results of any monitoring samples that represent the employee's exposure. If the results of monitoring conducted indicate exposure above the permissible exposure limit, a written notice will be provided. The written notice must include as statement that the PEL was exceeded and a description of the corrective actions taken to reduce the exposure below the PEL. 1. If the initial monitoring discloses exposure below the action level, additional monitoring will not be required unless: a) There has been a change of production, process, control, or personal change that may result in new or additional exposures. b) Whenever the company, the employee or the client has any other reason to suspect a change that may result in new or

additional exposures. c) Whenever an employee reports that they may be exposed above the action level. 2. If the initial monitoring discloses exposure at or above the action level and below the PEL, air monitoring and personal air sampling of 25% of the represented work force will be conducted. 3. If the initial monitoring discloses exposure above the PEL, air monitoring will be conducted periodically to confirm cadmium levels are below the action level. If our initial determination reveals that employee s exposures will be above the PEL, attempts will be made through administrative and engineering controls to reduce exposures below the PEL. Engineering and administrative controls will include, but are not limited to wetting down contaminated dust and rotating employees in regulated areas. If this should fail to reduce the exposure level, employees shall wear the appropriate level of personal protective equipment (PPE) necessary to reduce exposures below the PEL. E. Accuracy Of Measurement: Sampling devices and equipment used to monitor exposure must be accurate (with a confidence level of 95%). Only certified laboratories will be selected for sample analysis. F. Regulated Areas: Regulated areas will be established where employee exposures are in excess of the PEL. 1. The regulated area must be segregated from the rest of the work place in a manner that will minimize the number of persons who will be exposed. 2. Access to the regulated area must be limited to persons authorized, trained, and designated as having access to the area. 3. All persons entering a regulated area must be trained, qualified, fit tested, and provided with respiratory protection in accordance with the Respiratory Protection Program. Documentation of training must be on file with the Project Supervisor and Safety Director. 4. Food, beverages, smoking products, chewing tobacco, or other smokeless tobacco, and chewing gum will not be consumed in the regulated area. Cosmetics will also not be applied. Drinking water may be consumed. G. Respiratory Protection: Respiratory protection must be used if engineering and work practices cannot reduce the exposure level below the PEL. Respirators will be used in the following circumstances:

1. While installing or implementing feasible engineering or work practice controls. 2. During maintenance and repair work when the client has established that engineering controls are not feasible. 3. Where engineering controls and supplemental work practice controls are not sufficient to reduce the exposure. 4. Respirator selection will be accomplished in accordance with the Respiratory Protection Program. 5. Respirators will not be issued to any employee not trained in the use, care, and selection. Respirators will not be issued to any employee not fit tested in the specific respirator issued. H. Protective Work Clothing: Protective Work Clothing will be provided at no cost to the employee as follows: 1. Coveralls or similar full-body work clothing. 2. Gloves and shoes or coverlets 3. Face shields or vented goggles when necessary to prevent eye irritation. Impervious clothing for employees exposed to arsenic trichloride. 4. Cleaning and replacement will be provided at least once weekly in a freshly laundered, clean, and dry condition. If the employee is exposed to cadmium of over 50 ug/m3 or in an area where more frequent washing is needed to prevent skin irritation, clothing will be provided daily. 5. Clothing shall be repaired or replaced to maintain its protection factor. 6. Clothing will only removed in designated change rooms and will be disposed of in containers clearly marked with the following: a) CAUTION: Clothing contaminated with cadmium; do not remove dust by blowing or shaking. Dispose of cadmium contaminated wash water in accordance with applicable Local, State, or Federal Regulations. 7. Contaminated clothing and/or equipment will not be shaken out by employees or taken outside of the designated change trailer. I. Housekeeping: All surfaces must be maintained free from accumulations of cadmium. Shoveling and brushing of floors and surfaces will be allowed

only if vacuuming with a HEPA equipped vacuum has failed to clean the surfaces. Air blowing is not permitted at any time. J. Hygiene Facilities: The following hygiene facilities will be provided to employees working in regulated areas. 1. Change Facilities will be provided with clean rooms equipped with storage facilities for street clothes and separate storage for protective clothing and equipment. 2. Showers will be provided where employees working in regulated areas. 3. Lunchrooms that have a temperature controlled positive pressure filtered air supply and readily accessible to employees working in regulated areas. 4. Employees must wash hands and faces prior to eating. 5. Lavatory facilities shall be provided. 6. Vacuums will be provided to clean protective clothing and shoes worn in areas where the exposure exceeds 50 ug/m3, in an area before entering change rooms, lunchrooms, or shower rooms required. K. Signs And Labels: Signs will be posted around the perimeter of the regulated area and labels will be used to identify samples, waste, contaminated clothing, and equipment will be utilized. 1. Signs stating the following will be posted in and around the regulated work area: DANGER CADMIUM CANCER HAZARD CAN CAUSE LUNG AND KIDNEY DISEASE AUTHORIZED PERSONNEL ONLY NO SMOKING OR EATING RESPIRATOR REQUIRED IN THIS AREA 2. Labels must be applied to all shipping and storage containers of cadmium:

DANGER CONTAINS CADMIUM CANCER HAZARD AVOID CREATING DUST CAN CAUSE LUNG AND KIDNEY DISEASE L. Medical Monitoring: Maul Electric, Inc. supports the practices necessary for early detection of cadmium exposure. The medical surveillance program supplements the primary goals of the cadmium exposure control program of preventing disease through elimination or reduction of airborne concentrations of cadmium, and sources of ingestion. The medical surveillance provisions incorporate both initial and ongoing medical surveillance. 1. Maul Electric, Inc will provide initial medical surveillance to employees who are occupationally exposed to airborne cadmium levels greater than the action level 30 days a year or above the PEL for greater than 10 days a year. This monitoring consists of visits with the physician to include a detailed occupational history and laboratory analysis per 1926.1127(l) (2), as required. To ensure appropriate medical surveillance is performed, we provide to the physician and/or representative copies of the regulation and appendices, a description of the employees duties, a list of the personal protective equipment worn by the employee, and past exposure assessment data. 2. All medical examinations, procedures, and blood Cadmium level sampling/analysis shall be conducted by licensed healthcare practitioners and/or physicians. Our medical surveillance program shall meet the requirements of 29 CFR 1926.1127(l). M. Medical Removal: Maul Electric, Inc will remove employees from work who have exposures to cadmium at or above the action level each time a periodic and a follow-up blood sample indicates that medical removal is necessary as required by 1926.1127 (l)(3),(4), & (6). We also remove employees from work who have exposures to cadmium at or above the action level when a health care professional determines that they have medical conditions which, when exposed to cadmium, places them at greater risk for those health problems. Employees who are removed from work will receive all wages, benefits, for a period of 18 months without loss of seniority or promotion opportunities. The company reserves the right to place an employee in a position, of equal responsibility, where the employee will not be exposed occupationally to cadmium. N. Employee Training: No employee will be allowed to perform any task which may result in exposure above the action level without training in this policy and the contents of 29 CFR 1926.1127 (cadmium), 1926.59 (hazard communication), and respiratory protection. Maul Electric, Inc. will ensure its employees receive the required training and all training records are

kept on file for at least one year. Documented training records will include the identity of the employee trained, signature of the instructor and date of training. Additionally, training must be provided in the following: 1. The health hazards associated with cadmium. 2. The quantity, location, manner of use, storage, source of exposure and the nature of the operation which could result in exposure and any necessary protective steps. The purpose, proper use, and limitations of respirators. 3. The purpose and description of the medical surveillance program, engineering controls, and work practices associated with the job. O. Monitoring Data Record Keeping: As a minimum, the following records will be maintained and accessible to the employee, client designated representative and employee designated representative. Monitoring records must be retained and maintained for a period of at least 30 years of the objective data relied upon. All environmental monitoring data including the date, number, duration, location, and results of each of the samples taken, including a description of the sampling procedure used to determine representative employee exposure. 1. A description of the sampling and analytical method used and evidence of their accuracy. 2. The type of respiratory protection worn, if any. 3. The name, social security number, and job classification of the employees monitored and all other employees whose exposure the samples represent. 4. The environmental variables that could affect the measurement of the employee s exposure. P. Medical Records Retention: The employer or the Physician must maintain medical records for at least 30 years. A medical surveillance record will be established and maintained as an accurate record for each employee subject to medical surveillance. The record shall include as a minimum: 1. The name, social security number and description of the employee s duties. 2. A copy of the Physicians written opinions. 3. The results of any exposure monitoring done for the employee and the representative exposure levels supplied. 4. Any employee medical complaints related to exposure to cadmium. 5. A copy of the medical examination results including medical and work history 6. A copy of the information provided to the physician as required by 1926.1127(l) (9). Q. Emergency Situations: In emergency situations, which involve a substantial release of cadmium, Maul Electric, Inc. shall ensure workers are protected by following all aspects of this program. This will include

limiting access to authorized employees, provision and use of PPE, exposure monitoring, medical surveillance, hygiene facilities, work practices, fugitive emission controls, and proper disposal. R. Maintenance of Ventilation Systems: If performing maintenance on ventilation systems, Maul Electric, Inc. will utilize dust suppression techniques and safe work practices to minimize exposure to cadmium. If engineering controls fail to reduce cadmium levels below the action level, appropriate PPE including gloves, coveralls, boots, head coverings, goggles, and respirators will be utilized. S. Program Review: This program will be evaluated at least every six months. All facets of the program will be included in the evaluation. The program will be reviewed to ensure it meets the requirements of 29 CFR 1926.1127.