Low Dose Rate and Pulsed Dose Rate Afterloaders UT MDACC Perspective. John Horton, Ann Lawyer, Firas Mourtada

Similar documents
Clinical Implementation of a High Dose Rate Brachytherapy Program. Hania Al Hallaq, Ph.D. Jacqueline Esthappan, Ph.D. Joann Prisciandaro, Ph.D.

Brachytherapy-Radiopharmaceutical Therapy Quality Management Program. Rev Date: Feb

NRC INSPECTION MANUAL

RADIOACTIVE MATERIALS REGULATORY GUIDE

105 CMR: DEPARTMENT OF PUBLIC HEALTH

Republic of the Philippines Department of Science and Technology PHILIPPINE NUCLEAR RESEARCH INSTITUTE Commonwealth Avenue, Diliman, Quezon City

Radiotherapy Licence Application Form

APPENDIX K DEPARTMENTAL QUALITY ASSURANCE PROCEDURES RADIATION ONCOLOGY PROSTRATE BRACHYTHERAPY PRESCRIPTION

The Alphabet Soup of Regulatory Compliance: Being Prepared for Inspections. Objectives. Inspections are often unannounced, so DOCUMENTATION

Radiation Control Chapter Use of Radionuclides in the Healing Arts

Clinical Implementation of Electronic Charting

HOWARD UNIVERSITY Position Description. POSITION TITLE: Radiation Safety Officer SALARY GRADE: HU-13. DATE REVISED: December 01, 2014 EEO CODE: 02

NRC INFORMATION NOTICE 91-71: TRAINING AND SUPERVISION OF INDIVIDUALS SUPERVISED BY AN AUTHORIZED USER

QUALITY MANAGEMENT PROGRAM FOR HUMAN RESEARCH SUBJECT UNIVERSITY OF CINCINNATI

University of Maryland Baltimore. Radiation Safety Procedure

AAPM Responds to Follow up Questions from Congress after Hearing on Radiation in Medicine

Fifty Shades Of Gray A Medical Physicists Guide as RSO. Kevin Nelson, Ph.D, CHP Mayo Clinic Florida

APEx Program Standards

2 Quality Assurance In A Diagnostic Radiology Department. 1.1 Aim. 1.2 Introduction. 1.3 Key Elements of Quality assurance

The Practice Standards for Medical Imaging and Radiation Therapy. Radiation Therapy Practice Standards

Republic of the Philippines Department of Science and Technology PHILIPPINE NUCLEAR RESEARCH INSTITUTE Commonwealth Avenue, Diliman, Quezon City

10/8/12. Radiation Reduction and Monitoring Program: What the FDA and Other Regulatory Agencies Want. Disclosures. Two Principles of Radiation Safety

Medical Errors in Radiation Therapy

Mobile Positron Emission Tomography

Doing Business As name (if applicable): 2. Mailing Address: (Street Address/City/State/Zip) 3. Physical Location: (Street Address/City/State/Zip)

Dose estimation of the radiation workers in the Cyclotron and. PET/CT center

University of Maryland Baltimore. Radiation Safety Procedure

RADIOLOGICAL MONITORING AND SURVEYS

Chapter 4732 Modifications Summary SEPTEMBER 30, 2016

The Delivery of Brachytherapy for Cervical Cancer: Organizational and Technical Advice to Facilitate High-Quality Care in Ontario

Swedish Radiation Safety Authority Regulatory Code

The Practice Standards for Medical Imaging and Radiation Therapy. Medical Dosimetry Practice Standards

The ASRT is seeking public comment on proposed revisions to the Practice Standards for Medical Imaging and Radiation Therapy titled Medical Dosimetry.

Regulatory Issues Licensure by State Department of Nuclear Safety/Homeland Security or NRC Current License required or a "Timely Filed Notice"

RADIOACTIVE MATERIALS REGULATORY GUIDE DIAGNOSTIC AND THERAPEUTIC MEDICAL PROCEDURES

STANDARD ITEM. 1.1 Title: Prevention of Radiographic-Inspection Ionizing-Radiation Hazard; accomplish

NAVSEA STANDARD ITEM. 1.1 Title: Prevention of Radiographic-Inspection Ionizing-Radiation Hazards; accomplish

Jean St. Germain, CHP, DABMP, RMP Attending Physicist Radiation Safety Officer Memorial Sloan-Kettering Cancer Center

The Quality Management Examination

API Qualification of Ultrasonic Examiners for Sizing Examination Program (QUSE) Candidate Orientation

Mandatory Licensure for Radiologic Personnel. Christopher Jason Tien

VANDERBILT Authorized User - Physician Application for: Date Submitted:

The Use of Checklists and Audit Tools for Safety and QA

Radiation Control Chapter RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS

RADIATION ONCOLOGY RESIDENCY SUPERVISION POLICY

SCOPE OF PRACTICE FOR CANADIAN CERTIFIED MEDICAL PHYSICISTS

OPERATIONAL RADIATION SAFETY

Radiation Protection Procedures for the Cincinnati Proton Therapy Center (CPTC)

Quality Products & Physics Services for Radiation Oncology. 1. Radiation Oncology Performance Enhancement (ROPE) Database. 2. TMA Web Portal Content

DRAFT REGULATORY GUIDE

HUMAN USE RADIATION SAFETY MANUAL

Michigan Department of Licensing and Regulatory Affairs Part 15 Computed Tomography Installations Guidance for CT Rules

Local Government Records Control Schedule

APPLICATION FOR RENEWAL OF A RADIOACTIVE MATERIAL LICENSE AUTHORIZING THE USE OFINDUSTRIAL RADIOGRAPHY

Patient Risk (Safety) in Radiation Therapy

2018 Hospital Outpatient Prospective Payment System Final Rule Summary

Licensing and Registration of Radiation Sources

Overview of TG262 on Electronic Record Keeping & Clinical Experience with ARIA. March 7, 2016 James Mechalakos Chair, TG-262

8/2/2012. ACR-ASTRO Radiation Oncology Practice Accreditation Program. Accreditation Program Goals

Radiation Licensure and Management (RS100) Course

DECONTAMINATION, AND REGISTRATION

REGULATORY GUIDE 4.3 TEXAS DEPARTMENT OF STATE HEALTH SERVICES RADIATION SAFETY LICENSING BRANCH (RSLB) P.O. Box Austin, Texas

An Update of Radiation Oncology Quality and Safety Initiatives

Fundamental Aspects of SBRT

Medical Errors and Medical Physics

NRC REGULATORY ISSUE SUMMARY CONTROL OF RADIATION DOSE TO VISITORS OF HOSPITAL PATIENTS

MARYLAND RADIATION CONTROL ADVISORY BOARD MINUTES December 4, 2017

Health Management Information Systems: Computerized Provider Order Entry

JOB DESCRIPTION Position: Registered Radiologic Technologist

RADIATION PROTECTION PROGRAM GUIDANCE

University of Maryland Baltimore. Radiation Safety Procedure

July April 2016 RAM NMED Events

Job Series Matrix. Effective/Revision Date: 04/01/2015. Job Purpose Job Purpose Job Purpose Job Purpose Job Purpose Job Purpose

RADIATION PROTECTION PROGRAM GUIDANCE

Rasmussen s s Performance-based Actions. Errors in Radiotherapy. One Example of Error Analysis in Radiotherapy. Errors. Bruce Thomadsen Shi-Woei Lin

SUP 08 Operational procedures for Medical Gas Pipeline Systems (MGPS) Unified procedures for use within NHS Scotland

Establishing a Radiation Safety Culture in Health Care

Steven Sutlief, PhD UC San Diego February 13 th, 2015

RADIATION SAFETY COMMITTEE

The Mammography Quality Standards Act Final Regulations Document #2

Diagnostic Imaging: Surveyor Education, Survey Experience, and Trends

Medicare Program: Hospital Outpatient Prospective Payment and Ambulatory Surgical Center Payment Systems and Quality Reporting Programs

RADIATION PROTECTION

RADIATION SAFETY PROGRAM

RADIATION CONTROL - REGISTRATION OF RADIATION MACHINES, FACILITIES AND SERVICES REGISTRATION OF RADIATION MACHINES, FACILITIES AND SERVICES

Medical Error Prevention

3D surface image guided based DIBH clinical implementation

RADIATION EXPOSURE CONTROL PLAN

Radiation Safety Initial Training Module 3 Policies and Procedures

University of Pennsylvania Environmental Health and Radiation Safety. Diagnostic Energized Equipment Radiation Safety Manual

DENOMINATOR: All final reports for patients, regardless of age, undergoing a CT procedure

UNIVERSITY OF VICTORIA X-RAY EQUIPMENT SAFETY POLICIES AND PROCEDURES

AMC 30% 40% 10% 20% Electric power(kw) kw 25,44. Rotation speed (rpm) rpm 40,00. Got the Cochlea to reach the maximum availability of water

Compliance with IR(ME)R in radiotherapy departments across England

Overview of TG262 on Electronic Record Keeping & Clinical Experience with ARIA. March 7, 2016 James Mechalakos Chair, TG-262

Radiologic technologists take x rays and administer nonradioactive materials into patients bloodstreams for diagnostic purposes.

Code of Practice for Radiation Therapy. Draft for consultation

MRI Device Compliance Martin Vogel, PhD Kimberley Poling Application Engineering Team Eastern USA

Disclosures/COI. Outline 8/2/2012. Quality and Safety In Modern Brachytherapy an AAPM Educational Symposium. None

Effective dose to patients and staff when using a mobile PET/SPECT system

Transcription:

Low Dose Rate and Pulsed Dose Rate Afterloaders UT MDACC Perspective John Horton, Ann Lawyer, Firas Mourtada

Collaborators Patricia Eifel, MD Anuja Jhingran, MD Paula Berner, BS, CMD Mandy Cunningham, BS Teresa Bruno, BS, CMD Mitch Price, MS Kent Gifford, PhD

Conflicts of Interest Nucletron sponsored research agreement supports a portion of this research Transpire sponsored research agreement supports a portion of this research

Course Objectives After this lecture, the participant should be able to discuss LDR and PDR remote afterloading units Issues to address when changing to a new radioisotopes, e.g., 137 Cs to 192 Ir, to treat a disease Issues to address when changing afterloading techniques, e.g., manual to LDR or LDR to PDR

LDR Afterloaders UTMDACC 4 Selectron LDR 137 Cs afterloaders for gynecological cases Average 3 cases per week Principal replacement for 226 Ra Manually afterloaded 137 Cs sources for small number of cases

Selectron LDR Afterloader 4 channels 1 for tandem 1 for each ovoid 1 spare 48 pellets, 2.5 mm dia. 20 active 5mgRaeq (36.135 U) nominal 137 Cs on surface of 1.5mm ceramic (borosilicate) bead, 0.5mm SS encapsulation 28 inactive pellets Ferromagnetic, 304 stainless steel

Selectron LDR Afterloaders Pellets sorted magnetically Active pellets stored in radiation protection safe Program active and inactive pellets in each channel Programmed pellets, in intermediate safe Compressed air transfer of pellets

Radium to Cesium 226 Ra tube sources, 22 mm PL, 14 mm AL Sources spaced uniformly tip to flange 3 mm spacers used, if required Loadings w/o spacers, sources loading Loadings w spacers, inches loading 137 Cs tube sources, 20 mm PL, 13.5 mm AL 2 mm spacers, sources loading 5 mm spacers, inches loading No spacers, short sources loading

Radium Tube Sources to Cesium Selectron Pellets in the Tandem 25.0 mm = Ra-226 tube source with 3mm spacer 22.0 mm = Ra-226 tube 2.5 mm tip screw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4 mm 2.5 mm Center of 1st tube source Note: each active pellet has a nominal activity of 5 mgraeq

226 Ra to Selectron LDR 226 Ra treatment plans historical tandem and ovoids treatments Selectron loadings for same dose distribution Tables translate 226 Ra to Selectron, sources and inches tandem loadings MDACC ovoids - 33mm Afterloaders

LDR Afterloader Advantages Reduction of radiation exposure to personnel Reduction in rectal dose Optimization variable geometry of active/inactive pellets

LDR Afterloaders Disadvantages Machine failure during pellet transfer Air pressure Power sags and surges out of round pellets Visitors interrupt treatment, increase time patient in hospital

Facility Considerations Shielding Maximum air kerma strength per hour Maximum total air kerma strength per week Uncontrolled areas - 1.0 msv per year, no more than.02 msv in any one hour, T = 1 Radiation workers,.05 Sv per year Location Multiple shielded rooms adjacent Near nurses station, surveillance

Facility Considerations Ancillary services Emergency power Compressed air Door interlock Area radiation monitors Emergency equipment, bail out pig Radiation signs, instructions Audio-visual communications Equipment arrangement in room and outside Afterloader, TCS, nurses console, etc.

Licensing Issues Licensed by USNRC or State Agency Registry of Sealed Sources and Devices Verify vendor registration before purchase of unit Say what you mean, do what you say Whatever you state you will do in license, you must do You can always do more, but never less

License Application Description of source and registry number Manufacturer and model # of afterloader Authorized users and qualifications Authorized medical physicist and qualifications Planned use of device Location of planned use

License Application Adequacy of shielding Floor plan Area radiation monitors Radiation detection devices survey meters Audiovisual equipment Machine operation indicators Security of the area and the sources Maximum activity of specified isotope in the facility at any time

License Application Training of operators Personnel monitoring Details of Quality Control Program Calibration techniques and frequency Routine QC procedures and frequency Leak tests procedures and frequency Qualifications of individuals performing procedures

License Application Emergency procedures, location Manuals, location Disposal of decayed sources Records Fee for application Signature of executive level administrator

Training Physicists/dosimetrists operation, programming, emergency procedures, radiation safety Nursing staff start/stop, emergency procedures, radiation safety Physicians emergency procedures, radiation safety

Afterloader Commissioning Source calibration Source positioning Timer accuracy Room and treatment unit surveys Interlock & indicator light checks Audiovisual device checks Accuracy of printouts Applicator tests

Treatment Planning System Commissioning Data input devices Data output devices Image reconstruction algorithms Dose calculation algorithms

Afterloader Quality Control Interlock checks Audiovisual device checks Area radiation monitor Accuracy of printouts Printer paper supply Door lights Indicator lights & audible alarms

Afterloader Quality Control Warning signs Manuals Air compressors Emergency power Timer accuracy Room and treatment unit surveys

Afterloader Quality Control Source calibration Source positioning Applicator tests

Problem Desire an intracavitary LDR brachytherapy program with remote afterloader. After 2009 Nucletron will not support the Selectron LDR remote afterloader. Manual 137 Cs sources are more difficult to obtain. PDR remote afterloader, potential solution

Nucletron PDR Afterloader Physical construction identical to Nucletron unit (mhdrv2) 192 Ir stepping source Source activity 18.5 74 GBq at installation Treatment Control Station software specific for PDR

PDR Remote Afterloader Simulates LDR with higher activity source exposed a fraction of each hour PDR source steps through the implant during irradiation pulse

PDR Afterloader Advantages Radiobiological models and measurements indicate PDR provides capability to simulate LDR Nursing care provided between pulses Patient has more certainty when treatment finishes Visitors between pulses Computerized optimization 3D imaging, planning, volumetric information required for true optimization

PDR Afterloader Disadvantages Potential for failure to retract source Low probability, never occurred AMC Amsterdam 5117 delivered pulses 272 obstruction during check cable insertion 5 obstruction during active source insertion 417 treatments 5 (1.2%) required adjustment 5 (1.2%) discontinued, medical reasons

AMC Amsterdam PDR Conclusions Errors occur and on rare occasion require treatment adjustment Errors don t always occur on first pulse Flexible catheters more problem than rigid applicators Check cable proven effective system to prevent problems with active source

Questions When do treatment interruptions that require treatment adjustment become a reportable event in US? Patient intervention No Catheter kinked during treatment - depends??? If can adjust to original prescription - perhaps??? If can t adjust to original prescription - probably??? If reportable, to whom??? FDA for machine -??? NRC/State for dosage -???

Facility Considerations Shielding Maximum air kerma strength per hour Maximum total air kerma strength per week Uncontrolled areas - 1.0 msv per year, no more than.02 msv in any one hour, T = 1 Radiation workers,.05 Sv per year Shielding adequate for 137 Cs LDR, should be adequate for same (cgy in any one hour) treatments with 192 Ir PDR Location Multiple shielded rooms adjacent Near nurses station, surveillance

Facility Considerations Ancillary services Emergency power Door interlock Area radiation monitors Emergency equipment, bail out pig Radiation signs, instructions Audio-visual communications Equipment arrangement in room and outside Afterloader, TCS, nurses console, etc.

Licensing Issues Licensed by USNRC or State Agency Registry of Sealed Sources and Devices Have copy of vendor registration before purchase of unit Say what you mean, do what you say Whatever you state you will do in license, you must do You can always do more, but never less

License Application Description of source and registry number Manufacturer and model # of afterloader Authorized users and qualifications Authorized medical physicist and qualifications Planned use of Device Location of planned use

License Application Adequacy of shielding Floor plan Radiation area monitors Radiation detection devices Audiovisual equipment Security of the area and the sources Maximum activity of specified isotope in the facility at any time

License Application Training of operators Personnel monitoring Details of Quality Control Program Calibration techniques and frequency Routine QC procedures and frequency Leak tests procedures and frequency Qualifications of individuals performing procedures

License Application Emergency procedures, location Manuals, location Disposal of decayed sources Records Fee for application Signature of executive level administrator

TRAINING Higher activity source training even more important Physicists/dosimetrists operation, programming, emergency procedures, radiation safety Nursing staff operation, emergency procedures, radiation safety, nurses buy-in essential Physicians emergency procedures, radiation safety

Afterloader Commissioning Source calibration Source positioning Room and treatment head surveys Interlock checks Audiovisual device checks Accuracy of printouts Applicator tests

Afterloader Commissioning Transit dose, high number of source transfers Machine reliability, number of transfers Nucletron specs 25,000, tested to 100,000 Transfer tubes, what radius of curvature results in failure

Treatment Planning System Data input devices Commissioning Data output devices Data transfer from TPS to Treatment Control Station Image reconstruction algorithms Dose calculation algorithms

Afterloader Quality Control Interlock checks Audiovisual device checks Area radiation monitor Accuracy of printouts Printer paper supply Door lights Indicator lights & audible alarms

Afterloader Quality Control Warning signs Manuals Emergency power Timer accuracy Source positioning Source calibrations Room and treatment unit surveys

LDR to PDR Prescriptions Geometry based Point A dose 3D planning

LDR to PDR Dose Distribution Radial dose function 137 Cs vs. 192 Ir 1.06 1.04 1.02 g( r) Ir-192 g( r) Cs-137 Ratio (Ir/Cs) Cs-137 vs. Ir-192 g(r) comparison 1 Anisotropy effect g(r), ratio of g(r) 0.98 0.96 0.94 0.92 g(r) for 137 Cs, 192 Ir, ratio Ovoid shielding 0.9 0.88 0.86 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5 Radial distance (cm)

LDR to PDR Activity Distribution Tube sources, fixed geometry, fixed activity Selectron pellets, fixed activity, variable geometry active/inactive pellets PDR stepping source, variable geometry, variable dwell times MCNPX2.5.e calculation Price, et al., AAPM, Annual Meeting 2005, TU-D-T-617-1

Selectron LDR Fletcher-Suit-Delclos Ovoids small ovoids - one ovoid with medium cap mini ovoids 30 degree short small ovoid ovoid - 33 mm long large cap short ovoid - 28 mm long medium cap 15 degree small ovoid short large cap 15 degree mini ovoid 30 degree small ovoid

FSD Selectron Ovoid Gifford

FSD Selectron Ovoid Bladder shield Gifford Rectal Shield

Fletcher Williamson Tandem and Ovoids Polysulfone ovoid body bladder shield solid on laterally cavity for shields medially set screw Nucletron catalogue

Rectal shield Dose plane 2 cm dia. Ovoid cap Fletcher Williamson Ovoid Screw inside cap Bladder shield Moritz display of ovoid geometry Price

LDR to PDR Ovoid Comparison % Difference map Small ovoid PDR Fletcher Williamson compared to LDR FSD 20 mgraeq, same active dwell positions for FW and FSD Dwell time same at each dwell position MCNPX2.5.e calculation Price, et al., AAPM, Annual Meeting 2005, TU-D-T-617-1

FSD (LDR) Rectal Shield FW (PDR) Bladder Shield

Rectal Shield Geometry Rectal Rectal FW FSD ID, mm 4 8 OD, mm 18 18 thickness, mm 2.1 5 Total surface, mm 2 344 458 largest face surface, mm 2 191 102 total shield volume, mm 3 254 510 Shield material for both FW and FSD is Densimet 17 (17 g/cm 3 )

MCNPX2.5.e calculation Price, et al., AAPM Annual Meeting, 2005, TU-D-T-617-1

LDR to PDR UTMDACC Schedule First treatment in mid-october 05 18.5 GBq (0.5 Ci) source Change source every two months No weekend treatments Evaluate program in January 06

end

Bladder Shield Geometry Bladder Bladder FW FSD Height, mm 7 5 OD, mm 18 18 thickness, mm 2 5 Total surface, mm 2 267 296 largest face surface, mm 2 91 58 total shield volume, mm 3 191 288 * Material for both FW and FSD is Densimet 17 (17 g/cm 3 )

FSD (LDR) FW (PDR) h h