Tracking No.: 92562 Status: Submitted RAILROAD COMMISSION OF TEAS Oil and Gas Division API No. 42- Oil Well Potential Test, Completion or Recompletion Report, and Log 1. FIELD NAME (as per RRC Records or Wildcat) LIN (WOLFCAMP) 2. LEASE NAME UNIVERSITY EAST 3. OPERATOR'S NAME (Exactly as shown on Form P-5, Organization Report) RRC Operator No. EP ENERGY E&P COMPANY, L.P. 253385 4. ADDRESS ATTN CHELSEA CHAPMAN PO BO 4660 HOUSTON, T 77210-4660 5. If Operator has changed within last 60 days, name former operator This facsimile W-2 was generated electronically from data submitted to the RRC. 6a. Location (Section, Block, and Survey) 6b. Distance and direction to nearest town in this county. 17, 44, UNIVERSITY LAND 18.9 MILES NW DIRECTION FROM OZONA 12. If workover or reclass, give former field (with reservoir) & Gas ID or oil lease no. FIELD & RESERVOIR N/A GAS ID or OIL LEASE # 105-41837 13. Type of electric or other log run 14. Completion or recompletion date Gamma Ray (MWD) 11/01/2013 Oil-0 Gas-G 7. RRC District No. 7C 8. RRC Lease No. 17576 9. Well No. 4417HH 10. County of well site CROCKETT 11. Purpose of filing Initial Potential Retest Reclass Well record only (Explain In remarks) Well # SECTION I- POTENTIAL TEST DATA IMPORTANT: Test should be for 24 hours unless otherwise specified infield rules. 15. Date of test 16. No. of hours tested 17. Production method (Flowing, Gas Lift, Jetting, Pumping- Size & Type of pump) 18. Choke size 12/01/2013 24 Gas Lift 76/128 19. Production during Test Period 20. Calculated 24- Hour Rate Oil - BBLS Gas - MCF Water - BBLS Gas - Oil Ratio Flowing Tubing Pressure 564.0 413 1929 732 225.0 Oil - BBLS Gas - MCF Water - BBLS Oil Gravity-API-60 o Casing Pressure 564.0 413 1929 44.2 915.0 21. Was swab used during this test? 22. Oil produced prior to test (New & Reworked wells) 23. Injection Gas-Oil Ratio Yes No 3497.0 573.0 REMARKS: N/A PSI PSI INSTRUCTIONS: File an original and one copy of the completed FormW-2 in the appropriate RRC District Office within 30 days after completing a well and within 10 days after a potential test. If an operator does not properly report the results of a potential test within the 10-day period, the effective date of the allowable assigned to the well will not extend back more than 10 days before the W-2 was received in the District Office. (Statewide Rules 16 and 51) To report a completion or recompletion, fill in both sides of this form. To report a retest, fill in only the front side. WELL TESTERS CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I conducted or supervised this test by observation of (a) meter readings or (b) the top and bottom gauges of each tank into which production was run during the test. I further certify that the potential test data shown above is true, correct, and complete, to the best of my knowledge. Signature: Well Tester Name of Company RRC Representative OPERATOR'S CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was prepared by me or under my supervision and direction, and that data and facts stated therein are true, correct and complete, to the best of my knowledge. EP ENERGY E&P COMPANY, L.P. Regulatory Analyst Type or printed name of operator's representative Title of Person (713) 997-5138 12/23/2013 LINDA RENKEN Telephone: Area Code Number Month Day Year Signature
SECTION III 24. Type of Completion DATA ON WELL COMPLETION AND LOG (Not Required on Retest) New Well Deepening Plug Back Other 26. Notice of Intention to Drill this well was filed in Name of EP ENERGY E&P COMPANY, L.P. 25. Permit to Drill, Plug Back or Deepen Rule 37 Exception Water Injection Permit DATE 07/30/2013 PERMIT NO. 767122 CASE NO. PERMIT NO. 27. Number of producing wells on this lease in this field (reservoir) including this well 71 50579.0 29. Date Plug Back, Deepening, Workover or Drilling Operations: Commenced Completed 31. Location of well, relative to nearest lease boundaries 8306.0 Feet From South Line and 31113.0 East Line of the UNIVERSITY EAST 32. Elevation (DF. RKB, RT. GR ETC.) 33. Was directional survey made other than inclination (Form W-12)? Yes 2702 GL No 34. Top of Pay 35. Total Depth 36. P. B. Depth 6783 MD:6848 6992 MD:15147 MD:15104 38. Is well multiple completion? Yes No 28. Total number of acres in this lease 08/06/2013 10/05/2013 767.0 30. Distance to nearest well, Same Lease &Reservoir 37. Surface Casing Determined by 39. If multiple completion, list all reservoir names (completions in this well) and Oil Lease or Gas ID No. FIELD & RESERVOIR N/A 40. Intervals Drilled by: 43. Rotary Cable 41. Name of Drilling Contractor Tools Tools NORAM #21 Field Rules CASING RECORD (Report All Strings Set in Well) Salt Water Disposal Permit Other Recommendation of T.D.W.R. Railroad Commission (Special) GAS ID or OIL LEASE # Oil-0 Gas-G PERMIT NO. PERMIT NO. Feet from Lease Dt. of Letter 08/01/2013 Dt. of Letter Well # 42. Is Cementing Affidavit Attached? Yes CASING SIZE WT #/FT. DEPTH SET MULTISTAGE TYPE & AMOUNT HOLE SIZE TOP OF SLURRY VOL. TOOL DEPTH CEMENT (sacks) CEMENT cu. ft. 9 5/8 40.0 985 CLASS C 460 12 1/4 0 825.6 5 1/2 17.0 15147 CLASS H 2365 8 3/4 985 3861.0 No 44. N/A LINER RECORD Size Top Bottom Sacks Cement Screen 45. TUBING RECORD 46. Producing Interval (this completion) Indicate depth of perforation or open hole Size Depth Set Packer Set From L1 7326 To 15054 2 7/8 7016 7005 From To From To From To 47. ACID, SHOT, FRACTURE, CEMENT SQUEEZE. ETC. Depth Interval Amount and Kind of Material Used 7326.0 15054.0 ADD PERFS W/3-1/8" GUN, 6 SPF, 60 DEGREE PHASE (30 STAGES). FRAC SAME 30 STAGES (SEE FRACFOCUS FOR DETAILS). 48. FORMATION RECORD (LIST DEPTHS OF PRINCIPAL GEOLOGICAL MARKERS AND FORMATION TOPS) Formations Depth Formations WFMPB1 (UPPER WOLFCAMP) 6587.0 MD: 6644.0 WFMPC (MIDDLE WOLFCAMP) 6783.0 MD: 6848.0 WFMPC1 (LOWER WOLFCAMP) 6921.0 MD: 7020.0 REMARKS: UNIVERSITY EAST #4417HH. KOP = 6622. THE AS DRILLED PLAT HAS BEEN REQUESTED AND WILL BE SUBMITTED ONCE RECEIVED. Depth
RAILROAD COMMISSION OF TEAS Oil and Gas Division Tracking No.: 92562 ELECTRIC LOG STATUS REPORT This facsimile L-1 was generated electronically from data submitted to the RRC. Instructions FORM L-1 When to File Form L-1: 0 with Forms G-1, W-2, and GT-1 for new and deepened gas, oil, and geothermal wells 0 with Form W-3 for plugged dry holes 0 when sending in a log which was held under a request for confidentiality and the period for confidentiality has not yet expired. When is Form L-1 NOT required: 0 with Forms W-2, G-1, and GT-1 filed for injection wells, disposal wells, water supply wells, service wells, re-test wells, reclassifications, and plugbacks of oil, gas or geothermal wells 0 with Form W-3 for plugging of other than a dry hole Where to File Form L-1: 0 with the appropriate Commission district office Filling out Form L-1: 0 Section I and the signature section must be filled out for all wells 0 complete only the appropriate part of Section II Type of log required: 0 any wireline survey run for the purpose of obtaining lithology, porosity, or resistivity information 0 no more than one such log is required but it must be of the subject well 0 if such log is NOT run on the subject well, do NOT substitute any other type of log; just select Section II, Part A below Operator Name: EP ENERGY E&P COMPANY, L.P. Field Name Lease Name LIN (WOLFCAMP) County CROCKETT SECTION I. IDENTIFICATION District No. Drilling Permit No. Completion 7C Date: 11/01/2013 767122 Lease/ID Well UNIVERSITY EAST No. 17576 No. 4417HH A. BASIC ELECTRIC LOG NOT RUN API No. 42-105-41837 SECTION II. LOG STATUS (Complete either A or B) B. BASIC ELECTRIC LOG RUN. (Select one) 1. Confidentiality is requested and a copy of the header for each log that has been run on the well is attached. 2. Confidentiality already granted on basic electric log covering this interval (applicable to deepened wells only). 3. Basic electric log covering this interval already on file with Commission (applicable to deepened wells only). 4. Log attached to (select one): (a) Form L-1 (this form). If the company/lease name on log is different from that shown in Section I, please enter name on log here: Check here if attached log is being submitted after being held confidential. (b) Form P-7, Application for Discovery Allowable and New Field Designation. (c) Form W-4, Application for Multiple Completion: Lease or ID No(s). Well No(s). LINDA RENKEN Regulatory Analyst Signature Title EP ENERGY E&P COMPANY, L.P. (713) 997-5138 12/05/2013 Name (print) Phone Date -FOR RAILROAD COMMISSION USE ONLY-
Tracking No.: 92562 STATEMENT OF PRODUCTIVITY OF ACREAGE ASSIGNED TO PRORATION UNITS Form P-15 This facsimile P-15 was generated electronically from data submitted to the RRC. The undersigned states that he is authorized to make this statement; that he has knowledge of the facts concerning the UNIVERSITY EAST LEASE EP ENERGY E&P COMPANY, L.P. OPERATOR, No. 4417HH WELL ; that such well is, completed in the LIN (WOLFCAMP) Field, CROCKETT County, Texas and that the acreage claimed, and assigned to such well for proration purposes as authorized by special rule and as shown on the attached certified plat embraces 260.0 acres which can reasonably be considered to be productive of hydrocarbons. - CERTIFICATE - I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was prepared by me or under my supervision and direction, and that data and facts stated therein are true, correct, and complete, to the best of my knowledge, Date 12/05/2013 Signature LINDA RENKEN Telephone (713) 997-5138 AREA CODE Title Regulatory Analyst
August 1, 2013 15291 JULIE WARD ***** EPEDITED APPLICATION ***** SC_253385_10541837_000000_15291.pdf 10541837 000000 --Measured-- 1299 ft FWL 1714805 EP ENERGY E&P CO LP 1001 LOUISIANA ST 2574 ft FNL 494162 RM 2628A HOUSTON T 77002 MRL:SECTION 83 C P-5# 253385 CROCKETT UNIVERSITY EAST #4417HH&RAD ND SUR-UL,BLK-44,SEC-17,--[TD=7600],[RRC 7C], The interval from the land surface to a depth of 900 feet must be protected. This recommendation is applicable to all wells within a radius of 200 feet of this location. Jack M. Oswalt, P.G. 8/1/2013