Guidelines for Operating the Ventilation System in Negative Pressure Isolation Rooms

Similar documents
July 10, reduce the risk of staff or patient airborne exposure to communicable diseases during surgical procedures (See Appendix A) and

Frequently Asked Questions about TB Protocols at Duke Hospital and Clinics ( Revision)

Isolation Precaution (Part 2) Protective Environment (PE) Room. Combined AII/PE Rooms. Contact Isolation 5/22/2017

Transmission Based Precautions (Isolation Guidelines)

Standard Precautions must always be used in addition to Transmission Based Precautions.

Objectives. Clinic Scenario. Addressing TB in Our Communities November 19, 2015 Curry International Tuberculosis Center

APPENDIX F SPUTUM INDUCTION

Number: Ratio of the airflow to the space volume per unit time, usually expressed as the number of air changes per hour.

WARD ISOLATION SUITE BASIC CONCEPTS and RESEARCH PROGRAMME. Malcolm Thomas Consulting Engineer March 2006

TUBERCULOSIS INFECTION CONTROL

A PRINTED copy of this guideline may not be the most recent version. The OFFICIAL version is located on IHNET at the Policies & Procedures Home Page

Communicable Disease Control Manual Chapter 4: Tuberculosis

Infection Control Care Plan for a patient with confirmed/ suspected Active Pulmonary Tuberculosis. Patient Demographic / Label

Replaces: 08/11/16. Formulated: 1/2000 TRANSMISSION-BASED PRECAUTIONS

Procedure for Control of Aspergillosis During Construction/Renovation Activities. Procedure No. 209

TB in the Correctional Setting Florence, Arizona October 7, 2014

Facility Tuberculosis (TB) Risk Assessment for Correctional Facilities

Single room with negative pressure ventilation in relation to surrounding areas

Infection Prevention Implementation and adherence to infection prevention practices are the keys to preventing the transmission of infectious diseases

AIRBORNE PATHOGENS. Airborne Pathogens: Microorganisms that may be present in the air and can cause diseases in exposed humans.

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

Duke Hospital and Clinics Hazard Specific Respiratory Protection Policy

Infection Prevention Control Team

Infection Prevention and Control for Phlebotomy

Lightning Overview: Infection Control

OH&ESD. Technical Data Bulletin

Infection Prevention and Control

Formal Interpretations Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014 edition

Developed in response to: Best Practice Infection Prevention and Control

Access to the laboratory is restricted when work is being conducted; and

NA REVIEWED/REVISED: DATE TO BE REVIEWED: 01/31/2016 EMERGENCY MEDICAL SERVICES

Isolation Care of Patients in Isolation due to Infection or Disease

Tuberculosis (TB) risk assessment worksheet

Self-Instructional Packet (SIP)

PRECAUTIONS IN INFECTION CONTROL

THE INFECTION CONTROL STAFF

To provide a comprehensive, integrated written policy to prevent or minimize employee exposures to tuberculosis (TB).

2014-OCT-15 TORONTO WESTERN HOSPITAL: MAIN BUILDING 399 BATHURST STREET, TORONTO, ON, CANADA M5T 2S8

Principles of Infection Prevention and Control

Practical Aspects of TB Infection Control

CARING FOR PATIENTS WITH SUSPECTED OR CONFIRMED PULMONARY TUBERCULOSIS POLICY

PRESENTORS Cyndi McCullough Andrew Yosten

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings

IC CONTACT and CONTACT PLUS PRECAUTIONS REV. JULY 2017

Standard Precautions

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

Infection Control Manual. Table of Contents

SECTION: PATIENT RELATED INFECTION CONTROL NUMBER: 2.1 TRANSMISSION BASED PRECAUTIONS

Outbreak Management 2015

Infection Control Readiness Checklist

Mask and Respirator Use in the Health Care Setting Sept 30/05 Customer Answers to Problem Solving Questions

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

NHS GREATER GLASGOW & CLYDE STANDARD OPERATING PROCEDURE (SOP)

NORTHERN ZONE SAN MATEO COUNTY FIRE AGENCIES (Brisbane, Colma, Daly City, Pacifica and San Bruno) EMS - POLICY MANUAL

Infection Control Prevention Strategies. For Clinical Personnel

INFECTION C ONTROL CONTROL CONTROL EDUCATION PROGRAM

Administrative Without, TB control fails. TB Infection Control What s New? Early disease prevention Modern cough etiquette

Infection Prevention and Control Annual Education Authored by: Infection Prevention and Control Department

Management of Negative Pressure Wound Therapy (NPWT) Guideline

DEPARTMENTAL POLICY. Northwestern Memorial Hospital

Infection Control Prevention Strategies. For Clinical Personnel

a. Goggles b. Gowns c. Gloves d. Masks

Objectives. IPC Open calls - bi-weekly series. Introduction to Infection Prevention & Control (IPC) Open Call Series

What You Need to Know

TUBERCULOSIS AND MULTI DRUG RESISTANT TUBERCULOSIS POLICY

Health Building Note Supplement 1 Isolation facilities for infectious patients in acute settings

Infection prevention & control

Australasian Health Facility Guidelines. Part D - Infection Prevention and Control D Building Elements

Briefing for providers in relation to service development for inpatient service for Airborne High Consequence Infectious Diseases.

Checklist for Office Infection Prevention and Control

HEALTHCARE GUIDELINES AND STANDARDS

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control

INFECTION CONTROL ORIENTATION TRAINING 2004

TRUST POLICY AND PROCEDURE FOR THE MANAGEMENT AND CONTROL OF DIARRHOEA AND VOMITING (NOROVIRUS) INFECTIONS

NEW EMPLOYEE ORIENTATION INFECTION PREVENTION AND CONTROL

II. HIERARCHY OF CONTROL MEASURES

INFECTION CONTROL ORIENTATION TRAINING 2006

Pulmonary Tuberculosis Policy

SANTA BARBARA SHERIFF-CORONER S BUREAU Still an Unhealthy Environment

WORKER PROTECTION AGAINST M. TUBERCULOSIS IN PATIENT CARE, DIAGNOSIS AND PATHOLOGY

Infection Prevention and Control and Isolation Authored by: Infection Prevention and Control Department

Infection Control Manual. Table of Contents

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

CORPORATE POLICY, STANDARDS and PROCEDURE NUMBER TBA POLICY TITLE RESPIRATORY PROTECTION

Risk Assessment for the TB Laboratory

ISOLATION TABLE OF CONTENTS STANDARD PRECAUTIONS... 2 CONTACT PRECAUTIONS... 4 DROPLET PRECAUTIONS... 6 ISOLATION PROCEDURES... 7

Pharmacy Sterile Compounding Areas

Personal Hygiene & Protective Equipment. NEO111 M. Jorgenson, RN BSN

Tuberculosis (TB) Procedure

Guideline for the Management of Patients with Known or Suspected Diarrhoea / Viral Gastroenteritis

DISEASE TRANSMISSION PRECAUTIONS AND PERSONAL PROTECTIVE EQUIPMENT (PPE)

ISOLATION PRECAUTIONS INTRODUCTION. Standard Precautions are used for all patient care situations, but they

Lincolnshire Partnership NHS Foundation Trust (LPFT) Title of Policy

SAMPLE: Environmental Rounds and Safety Assessment Tool

2014 Annual Continuing Education Module. Contents

Guidelines on Infection Prevention and Control for Cork Kerry Community Healthcare 06: Transmission Based Precautions

Department of Public Health Infection Control Survey

Compounded Sterile Preparations Pharmacy Content Outline May 2018

Examination Centre Handbook 2014/2015

Infection Prevention and Control Guidelines for Cystic Fibrosis Patients

Transcription:

s Guidelines for Operating the Ventilation System in Pressure Isolation s Contents Purpose... 1 Scope/Audience... 1 Definitions... 2 Associated Documents... 2 1. Procedures... 2 1.1 Equipment... 2 1.2 Setting up for negative pressure Isolation... 2 1.2.1 Check the status of the room pressure... 3 1.3 Accessing negative pressure isolation rooms... 4 1.4 Discontinuing negative pressure isolation... 4 1.5 Using negative pressure rooms for induced sputum procedures (suspected or confirmed infectious pulmonary tuberculosis cases)... 5 2. General notes... 6 Measurement/Evaluation... 6 References... 6 Appendix: CDHB patient rooms with negative or positive pressure air handling... 7 Purpose To ensure that the negative pressure isolation room is d appropriately and safely by staff caring for patients known or suspected to be infected with micro-organisms transmitted by the airborne route These guidelines provide information on the utilisation of the ventilation system in the negative pressure isolation rooms located in the Canterbury District Health Board hospitals. These instructions must be available in areas with negative pressure isolation rooms. Scope/Audience All CDHB and contracted staff Ref: 4813 Page 1 of 8 Be reviewed by: February 2020

s Definitions A Pressure Isolation incorporates a ventilation system designed so that air flows from the corridor into the negative pressure room, ensuring that contaminated air cannot escape from the negative pressure room to other parts of the ward. Air naturally moves from areas of higher pressure to areas of lower pressure. When negative pressure exists, a continuous air current enters the room under the door, which prevents airborne particles generated in the room from escaping into the corridor. Associated Documents CDHB IPC Policy Care of Patients with Pulmonary Tuberculosis CDHB IPC Policy Transmission Based Precautions Isolation Guidelines Burwood Hospital Policies and Procedures - Instructions to Enable / Disable Isolation s Flowchart 1. Procedures 1.1 Equipment Burwood Hospital- Key/manual operated switch & Siemens electronic keypad - contact IPC service OR afterhours contact the Duty Nurse Manager/ Clinical Team Co-ordinator Christchurch Hospital Key/manual operated switch & Siemens electronic keypad (refer to location manual) Particulate respirator/n95 mask available in a variety of sizes Door signage indicating Airborne Precautions 1.2 Setting up for negative pressure Isolation There are a number of different types of negative pressure airflow systems in within the CDHB and not all are switched off between patients. Please check which type of negative pressure system is in place before using the room. For rooms that have doors and windows that open to the outside of the building, ensure windows are closed and remove key for door lock, window winder and lock door bolt for as long as the room is d for negative pressure isolation. Ref: 4813 Page 2 of 8 Be reviewed by: February 2020

s Ensure the door between the corridor and the ante room is closed. 1.2.1 Check the status of the room pressure Siemens electronic key pad Check Siemens display panel. If green and is displayed, put room into isolation mode before admitting patient into the room. Burwood Hospital- contact IPC service OR Duty Nurse Manager/ Clinical Team Coordinator to access key pad Before admitting patient into the negative pressure room, check that the Siemens display panel is green and is displayed. It will take approximately 2 minutes to get to negative 15pa Key/manual operated negative pressure air flow system Check if the negative pressure airflow system is running. If not start the negative pressure airflow system. Turn the key/switch from off to on. Christchurch Hospital - Allow at least 5 minutes for the light indicator to turn green and for the pressure differential needle (if installed) to reach 10-15 pascals. Burwood Hospital -wait for light indicator to turn red and pressure differential needle to reach 2-6 Pascals. If this does not occur contact maintenance and engineering (out of hours via duty management). Once the negative airflow is established remove the key and place the key in the key storage area. The airflow must be running at negative pressure BEFORE the patient is admitted to the room. Ref: 4813 Page 3 of 8 Be reviewed by: February 2020

s 1.3 Accessing negative pressure isolation rooms Before every entry check that there is a negative pressure operating in the room. Siemens electronic key pad Check that the display panel is green and there is a negative pressure of between - 10 & - 15pa. If room alarms, and display panel is red check that all doors are closed properly. If room is still alarming immediately contact Maintenance & Engineering via the Charge Nurse Manager or out of hours contact the Duty Nurse Manager/ Clinical Team Co-ordinator. Please DO NOT adjust the alarm at the keypad or at the nurse s station. Key operated negative pressure air flow system Check the green light indicator/pressure reading is between - 10 & - 15 Pascals. N.B. A red light indicates there is a malfunction of the ventilation contact maintenance and engineering. Once the patient is in the room, access should be via the anteroom door whenever possible. Ensure both main door and anteroom door remain closed at all times. N.B. The anteroom doors are designed to allow only one door to be opened at any one time. Put on an N95 particulate respirator/mask in the anteroom before entering the patient s room. 1.4 Discontinuing negative pressure isolation Refer specific disease guidance for clinical indications to discontinue negative pressure isolation. Siemens electronic key pad When the room is no longer required for negative pressure isolation put the room into normal mode : Burwood Hospital - contact IPC service or Duty Nurse Manger/Clinical Team Co-ordinator to access keypad Check Siemens display panel. When green and is displayed, room can be cleaned before for next patient admission. Ref: 4813 Page 4 of 8 Be reviewed by: February 2020

s Terminal clean is not required unless d with other transmission based precautions (refer specific disease requirements) Key operated negative pressure air flow system ONLY The following steps must be undertaken if the negative airflow is no longer required in the key operated negative pressure airflow rooms ONLY (i.e. patient is deemed to be non-infectious) or following discharge of an infectious patient. NB The room CAN NOT BE USED FOR NEW ADMISSIONS until the steps have been undertaken in the following order. Maintain negative pressure airflow in the room for at least 60 minutes before switching to Normal/Off mode. If ward/unit staff or contracted staff enter the room during this period they must wear a N95 particulate respirator/ mask After 60 minutes, turn the key on the panel to normal/off. The green light will go off and the red light switch on. The pressure gauge will move to zero. There will still be some ventilation coming into the room while turned off but it will no longer be negative pressure. Remove the key and return to the key storage area. Terminal clean is not required unless d with other transmission based precautions (refer specific disease requirements). Refer also to CDHB IPC Policy, Transmission-based precautions, Airborne Precautions 1.5 Using negative pressure rooms for induced sputum procedures (suspected or confirmed infectious pulmonary tuberculosis cases) Induced sputum procedures generate aerosolised particles. For patients suspected or confirmed with infectious pulmonary tuberculosis, induced sputum procedures shall be undertaken in a room that operates negative pressure ventilation. The physiotherapy department is responsible for locating a suitable room and undertaking the procedure using airborne precautions. At the end of the procedure, after the patient has left the room, the physiotherapist will wipe down surfaces and place a sign on the exterior or the room door, indicating the down-time when the room cannot be d. The down time is dependent on the number of air changes that the ventilation system is set at and may differ between rooms d. Ref: 4813 Page 5 of 8 Be reviewed by: February 2020

s The following down-times are applicable for induced sputum procedures: Bronchoscopy Suite (Endoscopy Unit, Christchurch Hospital) 30 minutes after end of procedure Ward 25 s 1 & 2-30 minutes after end of procedure All other negative pressure rooms including those in AMAU -60 minutes after the end of the procedure 2. General notes Measurement/Evaluation The exhaust grills and filters are changed when required as monitored by Maintenance and Engineering. Maintenance and Engineering staff will make contact with ward staff when this is due. An alarm will appear on the Building Management System (BMS) if there are any problems with the negative pressure mode. Staff in the area will be alerted to this by Maintenance and Engineering staff and again when the problem has been resolved. If negative pressure is compromised or if staff are informed of problem by maintenance staff, consider moving patient to an alternative room within 30 minutes and place surgical mask on the patient in the interim. Staff awareness of procedure during environmental audits. Maintenance dept. records of work carried out according to schedules. When in rooms are monitored by BMS in engineering and are verified every 12 months by an external independent audit company. References 1. Centres for Disease Control and Prevention. Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Healthcare Settings 2007. 2. Occupational Safety and Health Services of the Department of Labour 2000. Managing Health and Safety Risks in New Zealand. 3. Ministry of Health. Guidelines for Tuberculosis Control in New Zealand 2010 Ref: 4813 Page 6 of 8 Be reviewed by: February 2020

s Appendix: CDHB patient rooms with negative or positive pressure air handling function Ward/ Unit number ID number e.g. E533 Type of pressure* Type of controls Ante room Christchurch Hospital Ward 25 1, 2 (gauge) Key switch ED CHOC All unit N/A Positive N/A N/A CHOC 1 LGE112 CHOC 4,5,9,10 LGE 27, 29, 37 & Positive No 39 Ward 21 14, 15 None Positive None visible shared BMTU All unit N/A Positive N/A N/A BMTU 7 LGE14 Both None visible ICU 11, 12 AMAU 11,12,13 G369, G339, (gauge) Key switch x3 G343 Ward 10 8 2.145 Ward 11 8 3.143 Bronchoscopy Suite Procedure 2 2/220 Over-ride switch only Christchurch Women s Hospital Level 5 511, 510?/5010 Key switch Level 4 Rm 2 4004 Key switch Level 2 216, 217 2101B/2102B Key switch Burwood Hospital Ward AG Ward BG Ward CG Ward DG 23 G442 11 G370 3 23 G370 G253 No Other information Shared open ante area Also humidified air units x 2 No visible pressure recording Ref: 4813 Page 7 of 8 Be reviewed by: February 2020

Ward B1 Ward C1 Ward D1 Ward B2 Ward C2 Ward D2 Infection Prevention & Control s 2 1297 21 1139 23 2 2287 21 23 2028 1035 2128 Ward FG 14a & 14b G64, G65 None visible Ward GG s 4 & 5 yes G21 G26 (gauge) Key switch Ward HG s 12a & 12b Ashburton Hospital AAU Bed 7 Fan-assisted air extraction only. Not officially classed as either a negative or positive pressure room Other CDHB facility G10, G20 None visible No Ref: 4813 Page 8 of 8 Be reviewed by: February 2020