ABOUT REVEAL LINQ DURING

Similar documents
TIPS AND TRICKS FOR ALERT MANAGEMENT. Reveal LINQ Insertable Cardiac Monitoring System

GET STARTED WITH YOUR REVEAL LINQTM SYSTEM. Patient Setup Guide

REVEAL LINQ OPTIMIZING PATIENT EDUCATION

CARDIAC DEVICE MONITORING

REVEAL. Patient Assistant 9538/9539. Clinician Manual. Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician.

Standards for insertion, follow up and explant of implantable loop recorders [ILRs] by non-medical staff

CLINICAL MEDICAL POLICY

Personal Health Monitoring Services SM VITAL SIGNS TRANSMITTER MODEL: VST 3 TM. Instruction Manual

Initial Clinic Setup Reference Guide. Merlin.net Patient Care Network (PCN)

Policy :Department of Cardiology

CLINICIAN MANUAL. LATITUDE Patient Management System

MEDICAL ALERT SETUP GUIDE

Implantable Loop Recorder (ILR)

Eleganza 3XC. Designed for ICU

Patient Education Guide

GLOBALMEET FOR BLACKBERRY GLOBALMEET FOR BLACKBERRY USER GUIDE

Liver tumour ablation

Grant Module Guide For Clubs

Health Alliance. Utilization Management Changes Overview. Maxine Wallner Director Provider Services. February 2017

Mortara Holter. Patient Instruction Manual

Endoscopic Ultrasound (EUS) or Endosonography

Element(s) of Performance for DSPR.1

Department of Neurosciences Occipital Nerve Stimulation after your operation. Information for patients

CLINICIAN MANUAL LATITUDE NXT. LATITUDE NXT Patient Management System

TSWF Cardiovascular CPG AIM Form User Guide January 2018

econsult econsult Introduction & Training Manual

Manager. 2. To establish procedures for selecting and acquiring biomedical equipment.

For patients who need heart monitoring while in hospital

Navigating Grants.gov

Magellan Healthcare 1 Frequently Asked Questions (FAQ s) For Magellan Complete Care of Florida Providers

Patient Release and Reactivation Reference Guide. Merlin.net Patient Care Network (PCN)

Marsh and McLennan Companies 2018 Overview: Best Doctors, Health Advocate, Cigna and MSK Direct October 12, 2017

Getting Ready for Surgery

PATIENT SAFETY PART OF THE JOINT COMMISSION SPEAK UP PROGRAM

UW MEDICINE PATIENT EDUCATION. Angiography: Radiofrequency Ablation to Treat Solid Tumor. What to expect. What is radiofrequency ablation?

CPOE EVALUATION TOOL (V3.5) USER INSTRUCTIONS (FOR ADULT AND GENERAL HOSPITALS ONLY)

TSWF Pulmonary CPG AIM Form User Guide September 2018

Optima 101: PARTICIPANT GUIDE

Soarian Clinicals View Only

This booklet will help you understand and prepare for your colonoscopy. Please take your time to read it.

An Introduction to FirstNet for Nurses

Admit and Discharge Transient Patients

Soarian Clinicals Results Viewing Quick User Guide

HMSA s Interventional Pain Management and Spine Surgery Program

SURVEYOR CENTRAL MONITORING SYSTEM

Recommendations for Adoption

Dear ACLS-A Student, Feel free to contact us if we can be of any assistance. Founder Iridia Medical

Find & Apply. User Guide

Medical Department Employee Return to Work Information Sheet

Your Cardioversion Explained NHS. Information Booklet for Patients and their Families. The Leeds Teaching Hospitals NHS Trust

Running head: ROOT CAUSE ANALYSIS 1

A AIRWAY Open the Airway B BREATHING Deliver two (2) Breaths. Code Blue Policy. Indications for Calling A Code Blue

Medtronic CareLink Network :: PACE article: Remote monitoring of ICDs: A prospective analysis Abstract Introduction

Magellan Healthcare 1 Frequently Asked Questions (FAQ s) For Magellan Complete Care of Virginia Providers

Your Plan Explained. MetLife. UnitedHealthcare Group Medicare Advantage (PPO) Group Number: 12359

Chat with a Doctor: On-Demand, Asynchronous Physician Advice

Discharge a Patient. Goal: Learn to discharge a patient from your facility.

Optima POC PARTICIPANT GUIDE

STANDARDIZED PROCEDURE HEPATIC ARTERY INFUSION OF CHEMOTHERAPY (Adults, Peds)

HMO West Pennsylvania Employees Benefit Trust Fund Benefit Highlights Active Eligible Members. Providers None $6,850 single / $13,700 family

Magellan Healthcare 1 Medical Specialty Solutions

Follow-up guide for patients. Pacemakers. Follow-up guide for patients

Protection and Convenience For You and Your Patient

Advanced Imaging and Cardiac Procedures Prior Authorization Update

Genesis Touch Video Conferencing Customer Training. Honeywell HomMed

Psychological Specialist

TSWF Clinical Pharmacy AIM Form User Guide January 2018

UW MEDICINE PATIENT EDUCATION. Angiography: Percutaneous or Transjugular Liver Biopsy. How to prepare and what to expect. What is a liver biopsy?

APHERESIS UNIT ORIENTATION

Online Application Help

The Changing Role CUSTOM MEDIA

Radiofrequency Ablation to Treat Solid Tumors

Pharmacy Technician Reference Guide. Written by Emily Moore

RISK EVALUATION AND MITIGATION STRATEGY (REMS)

SURGICAL SERVICE SPECIALTY. Set Up and Safe Operation of Equipment

Connect HF Solution. Case Study. Reducing 30-Day Heart Failure. How Process Optimization and Peer-to-Peer Connections Standardized HF Care

Sleep Solution for Magellan Complete Care of Virginia Members. Provider Training Program for Sleep Management Presented By:

Unit 4 Safety, First Aid, Disease

STANDARDIZED PROCEDURE LUMBAR DRAIN INSERTION (Adults, Peds)

V.A.C. Therapy Patient Information Booklet. Brought to you by KCI, an Acelity company

TTNI Safety Policy. d. Controlled Drugs: Controlled substances are NOT allowed at this time.

Patient Care. Medical Knowledge

Using PowerChart: Organizer View

REVIEW OF PROVIDENCE ALASKA MEDICAL CENTER CERTIFICATE OF NEED APPLICATION FOR CONSTRUCTION OF AN ELECTROPHYSIOLOGY LABORATORY

Mandatory Licensure for Radiologic Personnel. Christopher Jason Tien

NIA Magellan 1 Medical Specialty Solutions

Provider s Frequently Asked Questions Availity in California

Position within the Organisation GP Research Lead

9/29/2014. Disclosure: I, Amber Sanders have no financial relationship to disclose. Objectives. Medication Safety in Pediatric Populations

Accreditation Program: Long Term Care

PATIENT EDUCATION GUIDE

Meaningful Use Roadmap

Quality Assurance Peer and Practice Assessment. Multi-Source Feedback Assessment Handbook

LATITUDE. Patient Management System

THANK YOU FOR JOINING

We re Tufts Health Plan, and our goal is better health and wellness for you.

On 4Culture s website, located at 4Culture.org, you will find our grant opportunities on our Grants and Artist Calls Page.

PHYSICIAN QUALITY REPORTING SYSTEM (PQRS) and e-prescribing Update James R. Christina, DPM Director Scientific Affairs APMA

DEFCON Authenticator. with Dual USB Port Hub

Summary Report for Individual Task E-1069 Maintain the KVG-72(*) Status: Approved

Transcription:

TALKING ABOUT REVEAL LINQ DURING CONSULT INTRODUCE THE SYSTEM o Help patients understand how the components work together Two primary components: Reveal LINQ ICM a small device that is inserted just under the skin during a minimally-invasive outpatient procedure MyCareLink Monitor a bedside unit that collects heart rhythm data from the ICM and makes it available to your doctor Optional component provided to some patients: Patient Assistant a small device used to manually mark symptoms in the Reveal LINQ ICM SET EXPECTATIONS o Ensure patients understand why long-term monitoring is recommended and how it will support informed treatment decisions o Set an expectation for how long patients will be monitored and how quickly they can expect to hear from a clinician o Point out that, once set up, the system is mostly automatic. The doctor will have access to heart data and will contact patients when necessary o Alert patients to possible insurance co-pays for monthly summary report review

lets your physician learn about your heart while you live your life. WORKING TOGETHER TO ANSWER QUESTIONS o Provide the Unlock the Answer Brochure Order additional brochures for free by logging on to MyOrders.medtronic.com. From the Quick Links menu select Order Patient Literature UNLOCK THE ANSWER The Reveal LINQ TM System o Encourage patients to sign up for Educational emails from Medtronic Patients can provide permission by returning the tear-off form in brochure or online at MonitorYourHeart.com/LINQsignup We ll help proactively answer common questions: What should I expect the day of insertion? (1 week before insertion) Did I get everything set up properly? (2 weeks post-insertion) Why am I being monitored again? (6 weeks post-insertion) How do I know everything is working? (3 months post-insertion)

TALKING ABOUT REVEAL LINQ FOLLOWING INSERTION GET PATIENTS STARTED o Review requirements for at-home setup of the MyCareLink Monitor o Perform the initial manual transmission before discharge and remind them that additional manual transmissions are not needed unless requested by clinician o Review how and when to use the Patient Assistant if prescribed SET EXPECTATIONS o Confirm with the managing physician that a follow-up appointment has been scheduled o Let patients know when they can expect to hear from a clinician

WORKING TOGETHER TO ANSWER QUESTIONS o Provide each patient with a Patient Information Kit Order additional kits for free by logging on to MyOrders.medtronic.com. From the Quick Links menu select Order Patient Literature o Attach sticker from inside this folder to the patient s MyCareLink reader for key reminders WELCOME Be confident using your Reveal LINQ System by starting with these SIMPLE STEPS: 1 2 Read the enclosed Setup Guide Visit MonitorYourHeart.com/LINQsetup Watch the Getting Started video Sign up to receive instructional emails REMEMBER Sleep near this monitor Don t push any buttons unless instructed Questions? Visit: MonitorYourHeart.com/ LINQhelp o Encourage patients to sign up for Educational emails from Medtronic Patients can provide permission by returning the form in the kit or online at MonitorYourHeart.com/LINQsignup o Remind patients to visit MonitorYourHeart.com/LINQhelp an ongoing resource for: Information on setup and use of system Answers to FAQs

TALKING ABOUT REVEAL LINQ DURING FOLLOW-UP TROUBLESHOOTING MISSING TRANSMISSIONS P Is the monitor located within 6.5 ft (2 m) of where the patient sleeps? P Is the monitor facing the foot of the bed? P Does the monitor receive constant power? P Is the monitor receiving adequate cellular signal? FREQUENTLY ASKED QUESTIONS How can I tell if my transmissions are being sent? Check the MyCareLink Monitor to see date of last successful transmission. (If the screen is dark, push the gray button just once.) Even if a day or two is missed, the system will try to send that data again for 14 days. Can I get an MRI? Yes, the Reveal LINQ ICM is safe for use in an MRI setting. Provide your device identification card to your imaging technician so he or she can access more information about specific MRI settings.

ERROR MESSAGES Error 5704 No cellular signal Your monitor does not have an adequate cellular signal Change the orientation of the monitor Change the location so it s near a window or outside wall If you can t find an adequate signal, contact Medtronic Patient Services at 1 (800) 551-5544, 7 am-7 pm CST System errors Your MyCareLink Monitor has encountered an internal error that does not mean there is a problem with your Reveal LINQ ICM Restart the monitor by disconnecting then reconnecting the monitor s power supply If the error image is still showing, contact Medtronic Patient Services at 1 (800) 551-5544, 7 am-7 pm CST. Refer to the error code to help Medtronic identify the problem. WORKING TOGETHER TO ANSWER QUESTIONS o Encourage Patients to Visit MonitorYourHeart.com/LINQhelp for answers to a comprehensive list of FAQs.

Brief Statement Indications Reveal LINQ LNQ11 Insertable Cardiac Monitor and Patient Assistant The Reveal LINQ Insertable Cardiac Monitor is an implantable patient-activated and automaticallyactivated monitoring system that records subcutaneous ECG and is indicated in the following cases: Patients with clinical syndromes or situations at increased risk of cardiac arrhythmias Patients who experience transient symptoms such as dizziness, palpitation, syncope, and chest pain, that may suggest a cardiac arrhythmia This device has not specifically been tested for pediatric use. Patient Assistant The Patient Assistant is intended for unsupervised patient use away from a hospital or clinic. The Patient Assistant activates the data management feature in the Reveal Insertable Cardiac Monitor to initiate recording of cardiac event data in the implanted device memory. Contraindications There are no known contraindications for the implant of the Reveal LINQ Insertable Cardiac Monitor. However, the patient s particular medical condition may dictate whether or not a subcutaneous, chronically implanted device can be tolerated. Warnings/Precautions Reveal LINQ LNQ11 Insertable Cardiac Monitor Patients with the Reveal LINQ Insertable Cardiac Monitor should avoid sources of diathermy, high sources of radiation, electrosurgical cautery, external defibrillation, lithotripsy, therapeutic ultrasound, and radiofrequency ablation to avoid electrical reset of the device, and/or inappropriate sensing as described in the Medical procedure and EMI precautions manual. MRI scans should be performed only in a specified MR environment under specified conditions as described in the Reveal LINQ MRI Technical Manual. Patient Assistant Operation of the Patient Assistant near sources of electromagnetic interference, such as cellular phones, computer monitors, etc., may adversely affect the performance of this device. Potential Complications Potential complications include, but are not limited to, device rejection phenomena (including local tissue reaction), device migration, infection, and erosion through the skin. Medtronic MyCareLink Patient Monitor, Medtronic CareLink Network and CareLink Mobile Application Intended Use The Medtronic MyCareLink Patient Monitor and CareLink Network are indicated for use in the transfer of patient data from some Medtronic implantable cardiac devices based on physician instructions and as described in the product manual. The CareLink Mobile Application is intended to provide current CareLink Network customers access to CareLink Network data via a mobile device for their convenience. The CareLink Mobile Application is not replacing the full workstation, but can be used to review patient data when a physician does not have access to a workstation. These products are not a substitute for appropriate medical attention in the event of an emergency and should only be used as directed by a physician. CareLink Network availability and mobile device accessibility may be unavailable at times due to maintenance or updates, or due to coverage being unavailable in your area. Mobile device access to the Internet is required and subject to coverage availability. Standard text message rates apply. Contraindications There are no known contraindications. Warnings and Precautions The MyCareLink Patient Monitor must only be used for interrogating compatible Medtronic implantable devices. See the device manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com. Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician.

Medtronic 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 medtronic.com Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals) UC201602400 EN Medtronic 2015. Minneapolis, MN. All Rights Reserved. Printed in USA. 11/2015