Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use

Similar documents
Using the Just Culture Method. Stacey Thomas, BSN, RNC Risk Analyst

Clinical Skills Validation: Alaris Pump System

To establish a consistent process for the activity of an independent double-check prior to medication administration, where appropriate.

VAN WERT COUNTY HOSPITAL. Policy/Procedure: Interdepartmental No.: N Issue Date: 6-90 By: Nursing No. of Pages: 9

Small-bore Connectors New Standards and Designs May 31, :15 4:30 pm

Alaris Products. Protecting patients at the point of care

WHAT are medication errors?

Hospital-wide Lean Project:

To describe the process for the management of an infusion pump involved in an adverse event or close call.

Bar Code Medication Administration and MAR Resource Manual

Patient Safety Case Study. Clara K. Terral. Angelo State University

Achieving safety in medication management through barcoding technology

Department Policy. Code: D: MM Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

Improving the Safe Use of Multiple IV Infusions

Launch Team Tool Kit

Adopting New Enteral Connectors

PROCESS FOR HANDLING ELASTOMERIC PAIN RELIEF BALLS (ON-Q PAINBUSTER AND OTHERS)

Alaris Guardrails Quick Overview for Staff Pharmacists

Patient Safety and Quality Measures for CRRT: The UAB Experience. Ashita Tolwani, M.D. University of Alabama at Birmingham CRRT 2012

Just Culture Toolkit Scenarios

Patient Safety. If you have any questions, contact: Sheila Henssler Performance Improvement/Patient Safety Coordinator Updated:

CRAIG HOSPITAL POLICY/PROCEDURE

POLICY. Clinician is any health care professional accepting responsibility for care of patients and their medications.

Policies and Procedures. Title:

10/9/2011. At the end of this program, the learner will be able to:

REVISED FIP BASEL STATEMENTS ON THE FUTURE OF HOSPITAL PHARMACY

Alaris System. Medication safety system focused at the point of care

CareFusion Overview Scott Bostick SVP/GM Pyxis Dispensing Technologies

To prevent harm to patients from adverse medication events involving high-alert medications.

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

Smart Pumps and Drug Libraries The Way Forward

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

PATIENT CARE MANUAL PROCEDURE

Accreditation Program: Long Term Care

Meeting the NEW RCN Standards for Infusion Therapy in practice

Electronic Medication Administration Process and Tips

STANDARDIZED PROCEDURE HEPATIC ARTERY INFUSION OF CHEMOTHERAPY (Adults, Peds)

Drug Events. Adverse R EDUCING MEDICATION ERRORS. Survey Adapted from Information Developed by HealthInsight, 2000.

Safe Medication Management Practices 2017/2018

Medication Safety & Electrolyte Administration. Objectives. High Alert Medications. *Med Safety Electrolyte Administration

Organizational Overview

Giving Intravenous (IV) Nutrition Through a Central Line with a CADD Pump

Recommendations from National Patient Safety Agency alerts that remain relevant to the Never Events list 2018

National Patient Safety Goals from The Joint Commission

INQUEST INTO THE DEATH OF: MARIE TANNER

Policies and Procedures. RNSP: RN Procedure. I.D. Number: 1067

Safe Medication Practices

Objectives. Demographics: Type and Services 1/22/2014. ICAHN Aggregate Results. ISMP Medication Safety Self Assessment for Hospitals

5th International Conference on Well-Being in the Information Society, WIS 2014, Turku, Finland, August 18-20, 2014

ABSTRACT. dose", all steps in the setup of the secondary infusion must be conducted correctly.

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

All about Your Implanted Venous Access Device (IVAD, Port )

Medication Administration Using the Home Pump (Eclipse)

(10+ years since IOM)

Adverse Drug Events: A Focus on Anticoagulation Steve Meisel, Pharm.D., CPPS Director of Patient Safety Fairview Health Services, Minneapolis, MN

Supplementary Appendix

Constant Pursuit of Medication Safety. Geraldine Koh Chief Pharmacist

Nurse Orientation. Medication Management

MEDICATION ASSISTANCE GUIDELINES: TEACHING PLAN

Medication Safety Dashboard

Case Study from Parallon

U: Medication Administration

Thanks to Anne C. Byrne, RN, Medical Monitor at Northwest Georgia Regional Hospital. This presentation was developed from one she designed for that

Medication Safety Action Bundle Adverse Drug Events (ADE) All High-Risk Medication Safety

Required Organizational Practices Resources for 2016

Plum 360 TM Infusion System with Full IV-EHR Interoperability

NHSGGC CME T34 SYRINGE PUMP COMPETENCY FRAMEWORK for PALLIATIVE CARE in ADULTS PRIMARY CARE

Infusion Therapy Learning Exercise: Infusion Documentation

INPATIENT UNIT MEDICATIONS. Best Practice Guidelines

DISCIPLINE COMMITTEE OF THE COLLEGE OF NURSES OF ONTARIO. PANEL: Joanne Furletti, RN Chairperson Rosalie Woods, RPN Member

PURPOSE To establish a standardized process for the activity of an independent double check for medication administration.

Using Clinical Data Categories with the Pyxis MedStation

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

Student name: Section: Date: Patient initials: Time began: Time ended: Points: Faculty: Points deducted due to:

DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES Medication Administration Observation

Objectives MEDICATION SAFETY & TECHNOLOGY. Disclosure. How has technology improved the way we dispense and compound medications AdminRx AcuDose Rx

Human Factors. Frank Federico, RPh. This presenter has nothing to disclose.

MEDICATION ADMINISTRATION: BELOW THE DRIP CHAMBER

RNSP: Advanced RN Intervention

Intravenous Infusion Practices and Patient Safety: Insights from ECLIPSE

Policy Statement Medication Order Legibility Medication orders will be written in a manner that provides a clearly legible prescription.

Alert. Patient safety alert. Promoting safer measurement and administration of liquid medicines via oral and other enteral routes.

ADMINISTRATION OF BLOOD PRODUCTS (RED CELLS, PLATELETS, PLASMA, & CRYOPRECIPITATE) NICU SYRINGE METHOD

Post-operative "Fast-Track" pathways for lung resection. Dennis A. Wigle Division of Thoracic Surgery Mayo Clinic

Administration of IV Medication in the Community by the Children s Community Nursing Team Standard Operating Procedure

1. Infection Control, Centers for Disease Control and Prevention (CDC). (2002). Guideline for hand hygiene in health-care settings

3/9/2010. Objectives. Pharmacist Role in Medication Safety and Regulatory Compliance

Maryland Patient Safety Center s Annual MEDSAFE Conference: Taking Charge of Your Medication Safety Challenges November 3, 2011 The Conference Center

Care of Patients Receiving Analgesia by Catheter Techniques Position Statement and Policy Considerations

Medication Errors in Chemotherapy PORSCHA L. JOHNSON, PHARM.D. CLINICAL PHARMACIST II MEDSTAR WASHINGTON HOSPITAL CENTER SATURDAY, SEPTEMBER 17, 2016

Human Milk. Neonatal Nursery Policy & Procedures Manual Policy Group: GI/GU Date Approved August 2012 Next Review August Approved by: Purpose

SARASOTA MEMORIAL HOSPITAL

Medication Safety Technology The Good, the Bad and the Unintended Consequences

Assessing and improving the use of near-miss reporting to prevent adverse events and errors in rural hospitals

Considerations for Sterile Compounding of Parenteral Products for Pediatric Use: Part 2 PharMEDium Lunch and Learn Series LUNCH AND LEARN

The Impact of CPOE and CDS on the Medication Use Process and Pharmacist Workflow

Storage, Labeling, Controlled Medications Instructor s Guide CFR (b)(2)(3)(d)(e) F431

Adverse Drug Events: A Collaborative Approach for Improvement. Mary Kathryn Cone, PGY-2

To provide protocol for medication and solution labeling to ensure safe medication administration. Unofficial Copy

Preventing Medical Errors

Transcription:

Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use Our vision is to create a culture where patients and those who care for them are free from harm. National Patient Safety Foundation (NPSF)

Learning Objectives Identify the importance of following standard processes to provide safe, highly reliable care. Discuss the elements required in the standard process for line reconciliation. Describe the importance of the new ENFit enteral system connectors to preventing dangerous misconnections. State when Alaris Guardrails should be used. Commit to performing these safe practices for every patient, every time.

Sharp s Key Safety Programs, Skills and Tools Just Culture Workforce Competence / Orientation / Annual Competency Programs TeamSTEPPS Patient and Care Partner Engagement Programs Learning and Reporting Systems to Identify Risks: RL Solutions Medication Safety Programs and Tools Always Events Program and Tools Lean Six Sigma (Robust Process Improvement) Change Acceleration Process (CAP) Tools Safe Use of Technology Tools Environmental Safety Programs

Always Events Every Patient, Every Time Sharp HealthCare has identified 7 critical patient safety practices that we expect to happen for every patient, every time. Our goal is to be a high reliability organization that habitually performs these 7 practices, which we refer to as Always Events. This module addresses Line Reconciliation and Guardrails Use. 1. Patient Identification 2. Treatment/Procedure Verification 3. Six rights of medication administration 4. Alaris Guardrails 5. Line Reconciliation 6. Universal Protocol 7. Hand Hygiene

Infusion Errors IV Infusion errors have occurred at every Sharp entity. These errors, harmful or not, are considered serious events because of their potential to cause patient harm. Through review of our adverse events and near misses several common themes emerged: Errors occurred with hanging the correct solution/medication Errors occurred during pump programming Error occurred in connection of the line

Infusion Errors Examples include: A laboring patient was bolused with pitocin instead of LR A 20mEq KCl IVPB was infused wide-open because it was connected to a port below the pump rather than above it A wrong dose of chemotherapy was administered because an incorrect weight was entered on the patient Neosynephrine was changed from single-strength to double-strength, but the Alaris pump was not reprogrammed accordingly, delivering twice the intended dose

Dangerous Misconnection Errors Examples include: An epidural set was inadvertently connected to IV tubing, resulting in patient death A non-invasive automatic B/P cuff tubing was erroneously connected to a saline-locked IV port by a family member after the patient ambulated to the bathroom. The patient received a fatal air embolism and died. An night shift RN inadvertently connected a small bore feeding tube to a central line port. The RN did not want to turn on the light to awaken the patient, and the line and tube were in next to one another. The patient died as a result of this error. These errors are enabled because the connectors for many lines and tubes are compatible, enabling potentially deadly misconnections. Incompatible connectors would have prevented these errors.

The Solution: Standard Work Standard work is a written description of the safest, highest quality, and most efficient way to perform a process or task* and benefits include: Clearly defines specific steps Captures best, safest practice Reduces variation Increases consistency Applies to all settings Easy to recognize deviation from the norm Allows for cross-monitoring A Standard process for performing Line Reconciliation has been established, which includes the following 3 steps. *Adapted from The Lean Handbook

Line Reconciliation: It s for More Than IVs What Needs to be Reconciled? All solutions being administered to the patient through a line or tube. This includes, but is not limited to: IV drips, IVPB, IV Fluids, IV Contrast PCA Epidural Bladder/Rectal Medication Instillation Tube Feedings Peripheral Nerve Blocks It is important to reconcile ALL lines and tubes to prevent a potentially harmful tubing misconnection. A dangerous misconnection is enabled because many medical lines and tubes have a luer connection, enabling tubes and lines to be accidentally connected.

ENFit: Enteral System Design Changes are Coming! International standards for unique connectors are being developed to prevent the potential for deadly misconnections. The first standards are for Enteral Systems, which we will begin to implement in early 2015. Look for information as to when products with these new connectors will be coming to your site. Until then, we must rely on human vigilance to prevent these errors.

Line and Tubing Tracing Trace ALL tubes and lines from the patient to the point of origin: before connecting or reconnecting any device or infusion at any transition, such as to a new setting or service as part of the hand-off process The process for reconciling IV lines is more specifically defined in the next several slides.

Line Reconciliation Process: When to Perform Line Reconciliation is performed when: Starting an infusion Replacing an empty infusion (bag, syringe, etc.) Changing concentration (e.g. single to double strength) Receiving a patient from another care area Patient is not responding to treatment as expected There is uncertainty about any element of the process Jointly during any RN-RN handoff (not for breaks) Note: Side by side & independent verification are still required on select high-risk medications.

Line Reconciliation Standard Work Step 1 A. Using your hand, physically trace the line from the solution through the pump, ensuring correct cartridge placement, on down to the patient. B. Verify fluids, medications & blood and enteral products against the order (e.g. IV drip, IVPB, IV fluid, PCA, Epidural, enteral) a) Name of infusion/ medication b) Concentration c) Dose / rate

Examples of Risk When Medications / Fluids are Not Verified Correctly Example #1: A wrong medication was hung because the RN did not verify the bag that the pharmacy tech delivered to the RN before it was hung. The infusion that was delivered was not the expected infusion, but rather a medication for a patient who was previously in the room but had transferred out of the unit. Example #2: D5.45NS was hung instead of D5.9NS because the IV bag had been mis-stocked in the wrong box.

Line Reconciliation Standard Work Step 2 Verify correct pump settings a. Correct profile on Alaris pumps b. Med/ fluid Guardrail selection (Guardrails are required for all fluids run on an Alaris pump) c. Concentration d. Patient weight for weightbased medications e. Dose/ rate

Examples of Risk When the Pump Programming is Not Verified Example #1: Milrinone was programmed at twice the ordered rate because the RN assumed that the concentration was single-strength rather than double-strength. Example #2: A double dose of magnesium was administered due to an error in pump programming that was not detected.

Line Reconciliation Process Step 3 Verify that the connection is secured to the correct port. Perform this process for each infusion, even those run on pumps other than Alaris.

Examples of Risk When the Connection is Not Confirmed A cardizem infusion was properly programmed and started but not delivered because the RN did not connect the infusion to the patient. A pre-op antibiotic was not delivered to the patient because the clamp was not opened. An infusion can be connected to the wrong line, resulting in a dangerous misconnection, such as connecting an epidural to an IV line.

Use of Alaris Guardrails Alaris pumps support patient safety through: Standardized drug libraries Standardized profiles for different care levels Soft and Hard stop alerts Using Guardrails for every patient, every time for solutions that are run on Alaris pumps, even for fluids without additives (e.g. NS, LR), reduces errors in pump programming.

Use Guardrails for Every Infusion, Every Time Why is it necessary to use Guardrails with IV fluids? How does it improve safety? Using Guardrails for every infusion run on an Alaris pump allows the practice to be hardwired. It takes the guess work out of deciding if an infusion requires Guardrails or if it doesn t. It allows units that use medication infusions infrequently to become comfortable with using Guardrails.

Example of Risk Created When Guardrails are Not Used A patient received a larger dose than ordered of heparin because of an error in the rate of the infusion. The error was not caught because the infusion was not programmed using Alaris Guardrails.

Summary Line / Tube Reconciliation is a process that requires: A. Placing your hand on each infusion and physically tracing the line from the solution, through the pump and into the patient. (it is a tactile and visual process) B. Reconciling the accuracy of the solution and pump settings against a primary source (e.g. MAR, order). 1. Verify fluids, meds & blood and enteral products against order 2. Verify correct pump settings 3. Verify the connection is secured to the correct route Line Reconciliation and Guardrails are Always Events, every patient, every time!