Humidity in Anesthetizing Locations Where Mechanical Systems and Compliance Collide

Similar documents
Guidelines for Best Practices for Humidity in the Operating Room

Quality Advisory THE ISSUE

Providing Quality Equipment and Services for Specialized Mechanical Air Systems. Serving Kentucky and Southern Indiana for over 70 years

Sterile Processing Department Design and HVAC Considerations

April 10, 2018 York Chan, CHFM, CHC, SASHE

Standard EC Elements of Performance for EC The hospital manages fire risks.

2016 Final CMS Rules vs. Joint Commission Requirements

4/7/15. ASC Regulatory Update and Survey Trends. Objectives. Disclosure. Describe recent changes to the CMS interpretive guidelines.

Byrd Barr Place Energy Assistance Program LIHEAP:

WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY. House as a System

Centerstone s PSE HELP Program:

Certified Healthcare Safety Professional (CHSP) Examination Blueprint/Outline

Healthcare-Associated Infections: State Plans

Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY. 1 WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM August 2010 eere.energy.

TOP 10 ASC COMPLIANCE FAQs

CSSD Vision on JCI Accreditation. Yaffa Raz, RN, BA, CSSD Manager Lady Davis Carmel Medical Center, Haifa, Israel

Certified Healthcare Safety Long Term Care (CHS-LTC) Examination Blueprint/Outline

2016 Sterilization Standards Update

Of Critical Importance: Infection Prevention Strategies for Environmental Management of the CSSD. Study Points

THE HEALTHCARE ENVIRONMENT

The Essentials of Maintaining Patient Normothermia

Update on Premarket Notification Requirements Concerning Gowns Intended for Use in Health Care

Observations will be made of the storage. knowledge of the hazardous materials. labeling the container to the use of. containers (which may range from

This course presents the applications of sterile processing theory in the clinical setting.

Department of Health Update

Environmental Controls and Monitoring of a DTRS - Comments and Responses

Certified Healthcare Safety Environmental Services (CHS-EVS) Examination Blueprint/Outline

QUESTIONS PERTINENT TO PRODUCT SELECTION:

Certified Healthcare Safety Nursing (CHSN) Examination Blueprint/Outline

Prepublication Requirements

Strategy/Driver Prevention Strategies Action Strategies

North East LHIN HELPING YOU HEAL. Your Guide to Wound Care. Surgical Wounds

CMS REQUIREMENTS: ESSENTIAL ELEMENTS FOR ASCS

North East LHIN HELPING YOU HEAL. Your Guide to Wound Care. Pilonidal Cysts

The Practice Transformation Support Hub. North Central ACH Regional Assessment and Technical Assistance

The Healthcare Environment Challenges and Update

Setting a new standard for performance, safety and simplicity

HEALTHCARE FACILITIES Planning, Design, Construction & Operations Healthcare Reform and the Implications to Our Industry What Lies Ahead?

PROCESS IMPROVEMENT AND ENHANCED QUALITY CARE ARE THE

The SIA: Overcoming Organizational Fear of Closure

The SIA: Overcoming Organizational Fear of Closure

Perioperative Learning Center Mission Statement: The mission of the Perioperative Learning Center is to provide excellence in the education and

PERIOPERATIVE CONSULTING SERVICES

MRI Device Compliance Martin Vogel, PhD Kimberley Poling Application Engineering Team Eastern USA

Certified Hazard Control Manager (CHCM) Certified Hazard Control Manager Security (CHCM-SEC) Examination Blueprint/Outline

Public Health Needs: Quality of Care and Sustainability an International Overview. Dr. David Jaimovich President

BRIGHT EYES SESSION. Bridging the gap through collaboration:

3.03 Functions of support services personnel Name

Mastectomy. Patient Education. What to expect, how to prepare, and planning for recovery after breast surgery. What is a mastectomy? How do I prepare?

Training Checklist - Veterinary Technician

Keeping Your ASC Survey Ready. Presenter Disclosures

ANSWERING TO A HIGHER CALLING

Charles Hughes. Instrument Reprocessing Update: What s New?

New Fire Safety Rules Summary Evvie Munley, LeadingAge

North East LHIN HELPING YOU HEAL. Your Guide to Wound Care. Negative Pressure

3M Sterile U Network 3M Sterile U Web Meeting January 16, 2014

EP20EO Clinical nurses are involved in the review, action planning, and evaluation of patient safety data at the unit level.

/ I N S T I T U T E t r a i n i n g c a t a l o g f a l l 2015

FACILITIES MANAGEMENT

REGULATORY & ACCREDITING AGENCIES

Health Care Construction Projects

Preparing for Life Safety Code Surveys with the Joint Commission - Part 2. Florida Hospital Association. Wednesday, May 2, 2018 WELCOME!

The How to Guide for Reducing Surgical Complications

An RN is circulating on a case when near the end, the surgeon hands the scrub

Rigid Containers for Immediate Use Steam Sterilization

Clinical guideline Published: 23 April 2008 nice.org.uk/guidance/cg65

Hospital-wide Lean Project:

No. 22 in In accordance to articles 152 & 108 / second of Labor Law no. (71) of 1987 we decided to issue the following instructions:

ROOM ATTENDANT. On completion of the Room Attendant Skills Programme, the learner will be able to:

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Teamwork, Communication, Briefing, Checklists, & O.R. Safety

Quality ID #424 (NQF 2681): Perioperative Temperature Management National Quality Strategy Domain: Patient Safety

Quality Assurance: Crisis to Control Linda L. Condon, MBA, BSN, RN Cynthia Spry, MSN, MA, RN, CNOR, CRCST

INFECTION CONTROL SURVEYOR WORKSHEET

COST SAVINGS AND EFFICIENCIES

Allied institute of professional Studies N. Broadway. #340. Chicago, IL Page 1

Weatherization Energy Auditor Single Family

1.5 to 5 Tons INDOOR COILS C33. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Overview. PPLHSL30 - SQA Unit Code HK6M 04. Ensure food safety practices are followed in the preparation and serving of food and drink

Joint Commission Intra Cycle Monitoring(ICM) Survey Results. Joint Conference Committee February 28,2017

Student Organization Housing. Project Initiation Request (PIR)

Minnesota Health Care Engineers Association. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

Expedition: Improving Safety and Reliability for Surgical Procedures

Visualizing the Patient Experience Using an Agile Framework

VAV-AHU Variable Static Pressure Control And Constant Static Pressure Control Comparison Test Report

Part I AAMI ST79 Recommended Practice

Ambulatory Surgical Center (ASC) INFECTION CONTROL SURVEYOR WORKSHEET

CMS Proposed Rule

Best Practices for MANAGING MEDICAL EQUIPMENT AND SUPPLIES

TABLE OF CONTENTS. iii

A. Air-Conditioned School A school with a central chilled water system designed to cool the major portions of the school.

Model Indoor Air Quality Management Plan

River Valley High School. Indoor Environmental Quality Management Plan. First Date Adopted January 10, 2013

Capital Projects Department. Denton City Council Department Presentation

The Evolution of a Successful Efficiency Program: Energy Savings Bid

Weatherization Inspector/Auditor Training

The Design Professional and Infection Prevention for Healthcare Facilities

New Maintenance Requirements from CMS. Intermountain Clinical Instrumentation Society

Sterile Processing in Healthcare Facilities

1 What is an AAAHC/Medicare Deemed Status survey? 2 What are the Medicare Conditions for Coverage (CfC)?

Transcription:

Humidity in Anesthetizing Locations Where Mechanical Systems and Compliance Collide Daniel Swanson Project Director Healthcare McKinstry Currently Acting Director of Facility Services & Construction UW-Northwest Hospital & Medical Center, Seattle, WA

Agenda Why is this a topic? Science! System Evaluation Why does this matter? What are the rules? How do you ensure compliance?

Why is this a topic? Lots of recent cases of hits on inspections Engineering and Clinical have different ways of measuring humidity Engineering has no good way to stay within standards mechanically There are no records of actions being taken Decisions being made aren t following the patient when a Tracer is done Staying in compliance is a waste of energy Operations are being affected / shut down Just to pass inspection? Patient Safety Risk reduction

Humidity. (h)yo oˈmidədē/ noun noun: humidity the state or quality of being humid. a quantity representing the amount of water vapor in the atmosphere or a gas

Science! Humidity vs Relative Humidity Air Water Warmer Air

Science! Latent Heat vs Sensible Heat Sensible Heat Changes Temperature Latent Heat Changes phase

Science! Dry Bulb Temp It s what you think of when you think of temp Wet Bulb Temp It s the temp you feel when you are wet

Science!

Science!

Science!

Science!

OK, that s some great theory. Can my systems even do that? Mechanical System Evaluation

Mechanical System Evaluation What systems are affected AHUs Cooling Coil Reheat Air flow Chiller Temp Capacity Flow From an FM perspective Can I meet my setpoints? How often? What are you doing?

Mechanical System Evaluation Iterative process Decide on a set of parameters for criteria Space temp, Design Day Evaluate current systems Coil performance (Using space temp, OAC, assumed load) Criteria met? Operational Evaluation Commissioning, cleaning, flow, controls system Redesign Coil size, static, Sensible vs latent, chw temp Cost? - Iterate Service Level Agreement / Budget

Mechanical System Evaluation

Mechanical System Evaluation

Mechanical System Evaluation

That s Great. Why do we care about humidity again? Why does humidity matter?

Why does this matter? High Humidity Infection Control Surgical Site Infections (SSI) Wound Care Supports Mold Growth Operating Room Comfort Low Humidity Tissue impact Static Discharge Fire Potential?

That sounds bad. Are there rules? Codes and guidelines.

Codes and Guidelines FGI 2010 ASHRAE 170 Table 7-1 Humidity and Temp Waiver AORN Perioperative Stds and Recommended Practices Safe Environment of Care - Recommendation V V.b and V.c NFPA-99 What s DOH say? FGI standards What do the docs say? COLDER!!

ASHRAE 170 Table 7-1

AORN Safe Environment of Care

NFPA 99 CMS currently adopts NFPA 101 2000 edition, which refers to an older version of NFPA-99 which has a 35% rh low limit References to OR humidity have been removed from newer versions of NFPA 99 CMS intends to adopt the 2012 edition of NFPA 101, which would eliminate the NFPA driven 35% low limit. CMS issued a waiver

Categorical Waiver

Seriously? How do I follow all those rules? Compliance tools and ideas

Waiver How to accept waiver Where to put waiver letter Example waiver letter

Service Level Agreement Get all stakeholders to the table Determine which codes/standards/guidelines you will follow Know how frequently you can or cannot stay in standards Know what it will cost to stay within standards Determine what standard to meet and how it will be met Compliance vs being in standard

Work Orders Work Order System Setup How to reorganize How to close the loop Flagging work orders Paperwork trail What do you do as the Engineering Department High side humidity vs low side humidity

OK, got it. I think. Can you summarize? Summary

Summary Science Codes Compliance Mechanical Evaluation

Questions?

Thank you! Daniel Swanson (206) 762-3311 dans@mckinstry.com