NOTICE. Re: GD207: Guidance on the Content of ISO Quality Management System Certificates Issued by Health Canada Recognized Registrars

Similar documents
IAF Mandatory Document for the Application of ISO/IEC in Medical Device Quality Management Systems (ISO 13485)

Raad voor Accreditatie (Dutch Accreditation Council RvA) Specific Accreditation Protocol for Certification according to ISO/IEC 13485

CMDCAS Handbook Policies and Procedures for Sector Qualification under the Canadian Medical Devices Conformity Assessment System (CMDCAS)

European IVD Regulations and Risk Based Classification. An Overview for Global Quality Professionals

IAF Guidance on the Application of ISO/IEC Guide 61:1996

Guide to reporting drug shortages and discontinuations GUI-0120

Pediatric Medical Device Development and Safety. Jacqueline N. Francis, MD, MPH Medical Officer, PSRB, ODE, CDRH, FDA

MEDICAL DEVICES SECTOR

NBCP PO C Administration of injections

Law on Medical Devices

EMERGING TRENDS WHAT I WILL COVER INCREASED INTEREST DEVICES ARE MIGRATING SAFE AND RELIABLE DEVICES LEAD TO LIVING WELL

May 2015 Assistive Devices Program Ministry of Health and Long-Term Care

Life Extension of Nuclear Power Plants

Leading Intimate Healthcare

MAIMONIDES MEDICAL CENTER. SUBJECT: Medical Equipment Failures and Medical Device Reporting Program

ASSE International Seal Control Board Procedures

STANDAR D FORMA T FO R PROVID ER BILLS

STANDARDS Point-of-Care Testing

SJMHS SAFE MEDICAL DEVICE ACT (SMDA) 7/2017

Nuclear Emergency Management

EA Cross Border Accreditation. Policy and Procedure for. Cross Border Cooperation. Between EA Members

The Practice Standards for Medical Imaging and Radiation Therapy. Cardiac Interventional and Vascular Interventional Technology. Practice Standards

Bill 59 (2012, chapter 23) An Act respecting the sharing of certain health information

APPLICATION FORM FOR AN EXEMPTION TO USE A CONTROLLED SUBSTANCE FOR SCIENTIFIC PURPOSES

GOVERNMENT OF THE RUSSIAN FEDERATION. DECREE of December 27, 2012 N On the Rules STATE REGISTRATION OF MEDICAL PRODUCTS

Brussels, 12 June 2014 COUNCIL OF THE EUROPEAN UNION 10855/14. Interinstitutional File: 2012/0266 (COD) 2012/0267 (COD)

Licensing application guidance. For NHS-controlled providers

Department of Health and Wellness Emergency Care Standards April 2014

Australian Standard. Clinical investigations of medical devices for human subjects. Part 1: General requirements AS ISO ISO :2003

Hygienic Management of Medical Devices in/for Health Care Facilities. The Austrian Way. Wolfgang Ecker Fed. Min. of Health, Family and Youth

Skilled nursing facility visits

The Practice Standards for Medical Imaging and Radiation Therapy. Quality Management Practice Standards

POLICIES AND PROCEDURES

(2) A renewal certificate of registration as specified in Form 17 shall be valid for one year.

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2017 S 2 SENATE BILL 750* Health Care Committee Substitute Adopted 6/12/18

UNM SRMC NURSE PRACTITIONER (NP) & LICENSED INDEPENDENT PRACTITIONER (LIP) CLINICAL PRIVILEGES. Name: Effective Dates:

General Internal Medicine Clinical Privileges REAPPOINTMENT Effective from July 1, 2015 to June 30, 2016

Laboratory Services Policy, Professional

Changes in the Medical Device Legislation; the day after. Jan Bart Hak 1

ROLE OF THE PERFUSIONIST

Appendix A.1 SURGICAL TECHNOLOGIST WORK PROCESS SCHEDULE AND RELATED INSTRUCTION OUTLINE

Hospitals Administration of Medical Equipment

Medical Devices Policy

The Practice Standards for Medical Imaging and Radiation Therapy. Radiography Practice Standards

Provider Profile GENERAL DETAILS STATE/ PROVINCE: OTHERS (PLEASE SPECIFY): CONTACT DETAILS DESIGNATION NAME PHONE MOBILE

Certified PICC Ultrasound Inserter CPUI Renewal Application

AS/NZS :2014. Single-use medical examination gloves AS/NZS :2014

53. MASTER OF SCIENCE PROGRAM IN GENERAL MEDICINE, UNDIVIDED TRAINING PROGRAM. 1. Name of the Master of Science program: general medicine

ISO INTERNATIONAL STANDARD. Medical laboratories Requirements for safety. Laboratoires de médecine Exigences pour la sécurité

EUROPEAN PARLIAMENT Committee on the Environment, Public Health and Food Safety

Ch. 117 EMERGENCY SERVICES 28 CHAPTER 117. EMERGENCY SERVICES GENERAL PROVISIONS EMERGENCY SERVICES PLANNING ORGANIZATIONS

IAF MLA Document. Policies and Procedures for a MLA on the Level of Single Accreditation Bodies and on the Level of Regional Accreditation Groups

PROPOSED AMENDMENT - NURSES (REGISTERED) AND NURSE PRACTITIONERS REGULATION. Health Professions Act

Psychological Specialist

TITLE 114 MEDICAL IMAGING and RADIATION THERAPY BOARD ARTICLE GENERAL ADMINISTRATION CHAPTER ORGANIZATION OF THE BOARD

Descriptions: Provider Type and Specialty

Performance of Point-of-Care Testing in Unaccredited Settings:

24 (b) "Boards" means the Board of Medicine and the Board. 27 graduated from an approved program, who is licensed to perform

CNAS-R01. Rules for the Use of Accreditation Symbols and Reference to Accreditation

NY EPO OA 1-09 v Page 1

Z: Perioperative Nursing Specialty

Health Canada Safety Codes

HSQF Scheme HUMAN SERVICES SCHEME PART 2 ADDITIONAL REQUIREMENTS FOR BODIES CERTIFYING HUMAN SERVICES IN QUEENSLAND. Issue 6, 21 November 2017

Review Process. Introduction. Reference materials. InterQual Procedures Criteria

GAO MEDICAL DEVICES. Status of FDA s Program for Inspections by Accredited Organizations. Report to Congressional Committees

Standards of Practice, College of Medical Radiation Technologists of Ontario

78th OREGON LEGISLATIVE ASSEMBLY Regular Session. House Bill 2028 SUMMARY

Health Facility Guidelines

Prerequisite Knowledge and Skills for Clinical Placements at SickKids

Establishment Registration and Device Listing. Michelle C. Jackson, Esq. Partner Venable LLP

general criteria New Zealand Code of Radiology Management Practice for accreditation

MEDICAL DEVICE GUIDANCE

IVDD revision changes to the European regulation of in-vitro diagnostic (IVD) Medical Devices. Med-Info. TÜV SÜD Product Service GmbH

RULES OF ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH CHAPTER FREESTANDING EMERGENCY DEPARTMENTS

April 17, Edition of the Joint Commission International Accreditation. SUBJECT: MITA Feedback on the 5 th Standards for Hospitals

Access to medical devices for Universal Health Coverage and achievement of SDGs

Payment Policy: Visits On Same Day As Surgery Reference Number: CC.PP.040 Product Types: ALL Effective Date: 03/01/2018

NHS RESEARCH PASSPORT POLICY AND PROCEDURE

Position Paper on Anesthesia Assistants: An Official Position Paper of the Canadian Anesthesiologists Society

Guidelines for Student Placements The Hospital for Sick Children

Placement Location Application Form. Diploma in Veterinary Nursing (DipVN)

2017 Summary of Benefits

Brachytherapy-Radiopharmaceutical Therapy Quality Management Program. Rev Date: Feb

Draft Regulation. 2. This Regulation comes into force on the fifteenth GAZETTE OFFICIELLE DU QUÉBEC, May 25, 2005, Vol. 137, No.

25/02/18 THE SOCIAL CARE WALES (REGISTRATION) RULES 2018

Permit. for nurses from outside Canada. Guide to obtaining a. from the Ordre des infirmières et infirmiers du Québec

PATIENT INFORMATION: CONTACT INFORMATION: EMERGENCY CONTACT: EMERGENCY PHONE: RESPONSIBLE PARTY (IF OTHER THAN PATIENT)

FAMILY HEALTH GROUP LETTER OF AGREEMENT. - among-

Facility Name: Patient Registration. Name: Address: Home: Work: Mobile: Race: Gender: Marital Status: Emergency Contact Information

ATI Annual Report

REGULATORY DOCUMENTS. The main classes of regulatory documents developed by the CNSC are:

COMMISSION IMPLEMENTING REGULATION (EU)

Notice. Update: Increased Scope of Submissions being accepted in Electronic Common Technical Document (ectd) electronic-only filing format

Official Journal of the European Union

Telemedicine services $0 copay Not applicable Primary care provider (PCP) CYD/Coinsurance CYD/Coinsurance CYD/Coinsurance CYD/Coinsurance

MEDICAL ON-CALL / AVAILABILITY PROGRAM (MOCAP) POLICY FRAMEWORK FOR HEALTH AUTHORITIES

National Accreditation Board for Certification Bodies. Accreditation Procedure. for. Energy Management Systems Certification Bodies

MEDICINES CONTROL COUNCIL

STATEMENT OF PURPOSE

The Newcastle upon Tyne Hospitals NHS Foundation Trust. Decontamination of Healthcare Equipment following Patient Use and Prior to Service or Repair

Transcription:

November 13, 2007 NOTICE Our file number: 07-126340-821 To: All Stakeholders Re: GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada is pleased to announce the release of the revised guidance document GD207: Guidance on the content of ISO 13485 quality management system certificates issued by Health Canada recognized Registrars. This guidance document supersedes the February 18, 2002 version (GD207/Rev0-MDB) of the same document. By way of transition, Rev0 will coexist with Rev1 until January 2, 2008 the date that Rev1 becomes effective. GD207 provides guidance to Manufacturers of Class II, III or IV medical devices and Registrars recognized by Health Canada on the essential information that Health Canada requires to be displayed on ISO 13485:2003 quality management system (QMS) certificates. This document has been revised to reflect CAN/CSA-ISO 13485:03, Medical devices Quality management systems Requirements for regulatory purposes, and other new or updated international standards. The most significant changes include: Several references to quality system have been replaced with "quality management system" (QMS). References to ISO 13485:2003 have been added and references to 13485:1996/8 have been removed. Most references to CMDCAS recognized Registrar have been replaced with Health Canada recognized Registrar. A new section, Supporting Documents has been added. The Definitions section has been renamed to Terms, definitions, and acronyms and has been revised and expanded. A new section, Revised certificates has been added. A new section, Implementation has been added. Certificate number has been renamed to Unique identification code, consistent with ISO 17021:2006. The section on Effective date and term of registration has been revised. Manufacturer s name has been revised and expanded. Manufacturer s address has been clarified. New guidance has been added on multi-site quality management systems. Guidance on the certificate s scope statement has been expanded. A new section, Format has been added. A new section, Language has been added. Certificate scope statement templates have been added under Appendix 1. Example certificate scope statements have been added under Appendix 2..../2

-2- Please direct any questions or comments regarding the content of this guidance document to the following: Quality Systems Section Medical Devices Bureau 150 Tunney s Pasture Driveway Main Statistics Canada Building, Room 1605 Address Locator: 0301H1 Ottawa, Ontario K1A 0K9 Phone: (613) 948-4370 Fax: (613) 946-6758 E-mail: ISO13485_CMDCAS_SCECIM@hc-sc.gc.ca

GUIDANCE DOCUMENT GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued by Health Canada Recognized Registrars Published by authority of the Minister of Health Date Adopted 2002/02/18 Revised Date 2007/10/29 Effective Date 2008/01/02 Health Products and Food Branch

Our mission is to help the people of Canada maintain and improve their health. Health Canada The Health Products and Food Branch s mandate is to take an integrated approach to the management of the risks and benefits to health related products and food by: minimizing health risk factors to Canadians while maximizing the safety provided by the regulatory system for health products and food; and, promoting conditions that enable Canadians to make healthy choices and providing information so that they can make informed decisions about their health. Health Products and Food Branch Minister of Public Works and Government Services Canada 2007 Également disponible en français sous le titre : GD207 : Directive sur les certificats de systèmes de management de la qualité ISO 13485:2003 délivrés par des Registraires reconnus par Santé Canada

Foreword Guidance documents are meant to provide assistance to industry and health care professionals on how to comply with governing statutes and regulations. Guidance documents also provide assistance to staff on how Health Canada mandates and objectives should be implemented in a manner that is fair, consistent and effective. Guidance documents are administrative instruments not having force of law and, as such, allow for flexibility in approach. Alternate approaches to the principles and practices described in this document may be acceptable provided they are supported by adequate justification. Alternate approaches should be discussed in advance with the relevant program area to avoid the possible finding that applicable statutory or regulatory requirements have not been met. As a corollary to the above, it is equally important to note that Health Canada reserves the right to request information or material, or define conditions not specifically described in this document, in order to allow the Department to adequately assess the safety, efficacy or quality of a therapeutic product. Health Canada is committed to ensuring that such requests are justifiable and that decisions are clearly documented. This document should be read in conjunction with the accompanying notice and the relevant sections of other applicable guidance documents. Revised Date: 2007/10/29; Effective Date: 2008/01/02 i

Document Change Log Document Number GD207/Rev1-MDB Replaces GD207/Rev0-MDB File name gd207_guidance_e.wpd Replaces cmdcas_scecim_certi134 85_e.wpd Version 1 Replaces 0 Date 2008-01-02 Date 2002-02-18 Change Location (section, paragraph) Nature of and/or Reason for Change 1 Overall document "quality system" replaced with "quality management system" (QMS) 2 Overall document References to ISO 13485:2003 added. References to 13485:1996/8 removed. 3 Overall document Most references to CMDCAS recognized/qualified Registrar changed to Health Canada recognized Registrar. 4 1.3 Supporting documents New section added. References several related and supporting documents. 5 1.7 Revised certificates New section added to address revised certificates. 6 1.8 Terms, definitions, acronyms Definitions section renamed, revised, and expanded. 7 1.9 Implementation New section added to specify the effective date of this guidance. 8 2.1 Unique Identification Code Certificate number renamed for consistency with ISO 17021:2006. 9 2.2 Certificate dates Effective date and term of registration has been clarified. 10 2.3 Manufacturer s name. Revised and expanded to address more complex situations. 11 2.4 Manufacturer s address Clarifications have been made. 12 2.5 Multi-site QMS New guidance added to address multi-site quality management systems. 13 2.6 Scope statement Guidance has been clarified and expanded. Revised Date: 2007/10/29; Effective Date: 2008/01/02 ii

14 2.12 Format New section added to address hard and electronic copy submission. 15 2.13 Language New section added to address official languages and multi-lingual certificates. 16 Appendix 1 Certificate scope statement templates added to facilitate their construction. 17 Appendix 2 Example certificate scope statements added to facilitate their construction. Revised Date: 2007/10/29; Effective Date: 2008/01/02 iii

TABLE OF CONTENTS 1.0 Introduction...1 1.1 Purpose...1 1.2 Scope...1 1.3 Supporting Documents...1 1.4 Background...2 1.5 Quality Management System Standard...3 1.6 Class I Manufacturers, Importers, Distributors, and Private Labelling...3 1.7 Revised Certificates...3 1.8 Terms, Definitions, Acronyms...3 1.9 Implementation...6 2.0 Content of a Certificate...6 2.1 Unique Identification Code...6 2.2 Certificate Dates...7 2.2.1 Effective Date...7 2.2.2 Expiry Date or Recertification Due Date...7 2.2.3 Period of Validity...7 2.3 Manufacturer s Name...8 2.3.1 Business Units of a Parent Company...8 2.3.2 Two or More Manufacturer s Names on a Certificate...9 2.4 Manufacturer s Address...9 2.5 Multi-Site QMS...9 2.6 Scope Statement...10 2.6.1 QMS Processes, Including Related Services...10 2.6.2 Device Listing...11 2.7 Signing Authority...12 2.8 Registrar s Name and Address...12 2.9 QMS Standard Audited Against...12 2.10 Record of Registrar s Recognition...12 2.11 Mark of Accreditation...12 2.12 Format...13 2.13 Language...13 Appendix 1: Scope Statement Templates...14 Appendix 2: Example Scope Statements...16 Revised Date: 2007/10/29; Effective Date: 2008/01/02 iv

1.0 Introduction 1.1 Purpose The purpose of this document is to provide guidance to Manufacturers of Class II, III or IV devices; and, Health Canada recognized Registrars on the essential information that Health Canada requires to be displayed on ISO 13485:2003 quality management system (QMS) certificates. 1.2 Scope The scope of this guidance document is limited to the essential information and format Health Canada requires displayed on a QMS certificate. 1.3 Supporting Documents This guidance document contains undated references. In these cases, the following documents apply: CAN-P-10B (ISO/IEC Guide 62:1996) - Criteria for Accreditation of Organizations Registering Quality Systems CAN-P-16 (ISO 17021:2006) - Conformity assessment Requirements for bodies providing audit and certification of management systems Food and Drugs Act ( R.S., 1985, c. F-27 ) http://laws.justice.gc.ca/en/f-27/ GD013/Rev00-MDB - Guidance on How to Complete the Application for a New Medical Device Licence Guidance for Industry - Private Label Medical Devices IAF GD2:2005 - IAF Guidance on the Application of ISO/IEC Guide 62:1996, General Requirements for Bodies Operating Assessment and Certification/registration of Quality Systems, Issue 4 http://www.iaf.nu/ Revised Date: 2007/10/29; Effective Date: 2008/01/02 1

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document ISO 9000:2005 - Quality management systems - Fundamentals and vocabulary ISO 13485:2003 (CAN/CSA- ISO 13485-03) Medical Devices -- Quality management systems -- Requirements for regulatory purposes ISO 15225:2000 Nomenclature -- Specification for a nomenclature system for medical devices for the purpose of regulatory data exchange ISO 17011:2004 - Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies Medical Devices Regulations SOR/98-282 (latest consolidated version) http://laws.justice.gc.ca/en/f-27/sor-98-282/ Q90R0e : 2000-04-19, Policy on the Canadian Medical Devices Conformity Assessment System (CMDCAS) 1.4 Background A Manufacturer will provide a valid certificate to Health Canada: to comply with sections 32(2)(f), 32(3)(j), 32(4)(p), and as applicable, 34 or 43.1 of the Medical Devices Regulations (MDR); as evidence of conformity with ISO 13485:2003; as evidence of having documented and effectively implemented applicable sections of the MDR into their QMS; and, to indicate those devices that are designed and/or manufactured under the certified QMS. ISO 17021:2006 states in the introduction, The form of attestation of conformity of an organization s management system to a specific management system standard or other normative requirements is normally a certification document or a certificate...the overall aim of certification is to give confidence to all parties that a management system fulfils specified requirements. Only valid certificates (see below) issued by Heath Canada recognized Registrars will be accepted as objective evidence of compliance with sections 32(2)(f), 32(3)(j), 32(4)(p), 34 (in some cases), or 43.1 of the MDR. No other form of documentation will be accepted by Health Canada as a substitute (for example [e.g.,] other certificates types, audit reports, letters, or attestations). Despite this guidance, any certificate which contains ambiguous or conflicting information may be subject to a request for additional information or may be refused by Health Canada. 2 Revised Date: 2007/10/29; Effective Date: 2008/01/02

1.5 Quality Management System Standard The MDR require the QMS under which Class II, III or IV medical devices are designed and/or manufactured satisfy the National Standard of Canada CAN/CSA-ISO 13485:03. There are no regulatory QMS requirements for Class I medical devices. Health Canada considers CAN/CSA-ISO 13485:03 and ISO 13485:2003 to be equivalent. 1.6 Class I Manufacturers, Importers, Distributors, and Private Labelling Organizations that exclusively design, manufacture, and sell Class I medical devices for Canada shall not receive certification under the Canadian Medical Devices Conformity Assessment System (CMDCAS). However, Manufacturers of Class I devices that also design, manufacture and sell Class II, III or IV devices for the Canadian market are eligible for certification under CMDCAS and may voluntarily include Class I devices and other medical devices not sold in Canada in the audit process and in their QMS certificate scope statement. The MDR do not require importers or distributors of medical devices to have a certified QMS. However, any importer or distributor of a Class II, III or IV devices that choses to become the Manufacturer by labelling and selling the device with their own name, trade-mark, design, trade name or other name or mark owned or controlled by them (see definition of a Manufacturer) shall comply with the QMS sections of the MDR and other applicable sections. A Manufacturer who will obtain medical device licences exclusively through Health Canada s Private Label process is not required to obtain a QMS certificate. See Health Canada s Website for additional details. 1.7 Revised Certificates Revised certificates shall be valid and be based on any supplementary audit and approvals by the Health Canada recognized Registrar, as appropriate (ISO 17021:2006 9.5.1, CAN-P-10B 3.5.4). Revised certificates will supercede and be clearly distinguished from any previously issued versions (ISO 17021:2006 8.2.3i)). 1.8 Terms, Definitions, Acronyms Accreditation Third-party attestation related to a conformity assessment body [that is (i.e.,) Registrar] conveying formal demonstration of its competence to carry out specific conformity assessment tasks (ISO 17011:2004). Revised Date: 2007/10/29; Effective Date: 2008/01/02 3

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document Certificate For the purposes of this document, an ISO 13485:2003 or CAN/CSA-ISO 13485:03 quality management system certification document, issued by a Health Canada recognized Registrar to be used by a Manufacturer for obtaining, maintaining, or amending a Health Canada medical device licence. Certificates issued by a CMDCAS recognized Registrar will bear the SCC s mark of accreditation. CMDCAS Canadian Medical Devices Conformity Assessment System CMDCAS Recognized Register Registrars that are recognized by Health Canada through the accreditation and sector qualification by the Standards Council of Canada (SCC). A list of CMDCAS recognized Registrars is on the Health Canada Website. Distributor Any person, partnership, corporation, association, or other legal relationship which stands between the Manufacturer and the retail seller in purchases, consignments, or contracts for sale of consumer goods. Generic Device Group Refers to sets of devices having the same or similar intended uses or commonality of technology. (ISO 15225:2000) Health Canada Recognized Register Includes both CMDCAS recognized Registrars and Registrars that are directly recognized under section 32.1 of the MDR. IAF International Accreditation Forum (www.iaf.nu) Importer For the purposes of this document, an importer is a person, other than the Manufacturer of a medical device, who causes the medical device to be brought into Canada for sale. ISO International Organization for Standardization (www.iso.org) 4 Revised Date: 2007/10/29; Effective Date: 2008/01/02

Manufacturer Means a person who sells a medical device under their own name, or under a trade-mark, design, trade name or other name or mark owned or controlled by the person, and who is responsible for designing, manufacturing, assembling, processing, labelling, packaging, refurbishing or modifying the device, or for assigning to it a purpose, whether those tasks are performed by that person or on their behalf. (SOR/98-282) MDR Medical Devices Regulations (laws.justice.gc.ca/en/f-27/sor-98-282/) Multi-Site (Organization) A multi-site organization is defined as an organization having an identified central function (normally, and hereafter referred to as a central office) at which certain activities are planned, controlled or managed and a network of local offices or branches (sites) at which such activities are fully or partially carried out. (IAF GD2:2005 Annex 3, 1.1.1) Private Label Manufacturer Means a person who sells a private label medical device under their own name or trademark. (Guidance for Industry - Private Label Medical Devices) Private Label Medical Device Means a medical device that is identical in every respect to a medical device manufactured by an original Manufacturer and licensed by Health Canada, except that the device is labelled with the private label Manufacturer's name, address and product name and identifier. (Guidance for Industry - Private Label Medical Devices) Quality Management System Management system to direct and control an organization with regard to quality. (ISO 9000:2005). Recognized Registrar The Minister shall recognize a person as a Registrar for the purpose of issuing quality management system certificates if the person: (a) has sufficient training, experience and technical knowledge in the design and manufacture of medical devices and in the effective implementation of quality management systems to determine whether a quality management system satisfies a standard referred to in paragraph 32(2)(f), 3(j) or 4(p); and (b) conducts quality management system audits in accordance with the applicable guidelines and practices established by the International Organization for Standardization. (SOR/2003-173, s. 3; SOR/2006-197, s. 3.) Revised Date: 2007/10/29; Effective Date: 2008/01/02 5

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document Registrar Organization that assesses and registers or certifies the quality management systems of Manufacturers with respect to published standards. NB1: Certification/Registration Body: A third party that assesses and certifies/registers the quality system of suppliers with respect to published quality system standards and any supplementary documentation required under the system. (CAN-P-10B). NB2: A Registrar may be called Certification Body (CB), Registration Body (RB) or Certification/Registration Body (CRB). NB3: In Europe, QMS assessment and registration can also be performed by Notified Bodies that have been found competent to do so by an accreditation body. NB4: Conformity Assessment Body (CAB): body that performs conformity assessment services and that can be the object of accreditation (ISO 17011:2004 3.10) SCC Standards Council of Canada (www.scc.ca). The national accreditation body of Canada. Valid Certification A certificate indicating conformity to all certification requirements and all the content requirements as defined herewith. 1.9 Implementation As of 2008/01/02, all newly issued and re-issued/revised certificates will be subject to this guidance. 2.0 Content of a Certificate 2.1 Unique Identification Code The certificate shall bear a unique identification code (ISO 17021:2006 8.2.3 d)). The code is assigned by the Health Canada recognized Registrar to reference a unique certification/ registration or a unique certificate document. Either practice is acceptable provided that it is consistent and maintains adequate traceability for the users of the certificate. Health Canada will use this code for administrative purposes. Registrars may choose a format that suits their operational needs, including embedding version control and other information in the code. However, the code is limited to 30 characters (without spaces). 6 Revised Date: 2007/10/29; Effective Date: 2008/01/02

2.2 Certificate Dates Based on section 32.2 of the MDR, Health Canada requires two dates to be displayed on a certificate: effective date; and, expiry date or recertification due date. Registrars may use a date format that suits their needs so long as it is unambiguous and consistent. To meet accreditation requirements (ISO 17021:2006 8.2.3b)), other dates will be displayed, but they must not confuse the dates required by Health Canada. 2.2.1 Effective Date Certificates shall bear an effective date. The field will be labelled Effective date and denote the commencement of the certificate s validity period. The effective date shall not precede the date of the certification decision (ISO 17021:2006 8.2.2). Device licences, licence applications, and applications to amend the name or address on a licence must always be supported by a valid certificate. A certificate whose effective date occurs in the future (post-dated) is not in effect, for the purposes of licensing. Consequently, a certificate received by Health Canada prior to the effective date will not be accepted. Date of Certification Decision # Effective Date # Date Received by Health Canada 2.2.2 Expiry Date or Recertification Due Date Certificates shall bear an expiry date or a recertification due date (ISO 17021:2006 8.2.3 c)) or both. The field(s) will be labelled expiry or expiry date or recertification due date and will denote the end of the certificate s validity period. 2.2.3 Period of Validity The period specified by the effective date and the expiry or the recertification due date shall not exceed three years (MDR section 32.2). If both expiry and recertification due dates appear on the certificate, the expiry date will be recorded by Health Canada. Revised Date: 2007/10/29; Effective Date: 2008/01/02 7

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document 2.3 Manufacturer s Name The certificate s main page shall identify the name of the Manufacturer to whom the certification applies (ISO 17021:2006 8.2.3 a)). The Manufacturer s name shall be the same as that used on the medical device licence and medical device label. An organization that sells a medical device under their own name, or under a trade-mark, design, trade name or other name or mark owned or controlled by them is defined as the Manufacturer (MDR Section 1). Health Canada will not accept certificates from a Manufacturer s subcontractor as evidence of compliance to MDR sections 32(2)(f), 32(3)(j), 32(4)(p), 34, or 43.1. Name on the Certificate = Name on the Licence = Name on the Device Label Some organizations have a complex structure, with multiple names, sites, and ownership. However, the identified Manufacturer shall bear the responsibility of complying with the MDR. In all situations, QMS documentation and certification agreements (ISO 17021:2006 5.1.2) between the entity(s) and the Health Canada recognized Registrar shall reflect the name(s) of the Manufacturer. 2.3.1 Business Units of a Parent Company Health Canada will recognize a portion of a legal entity that is empowered to sign a device application, to be a legal entity for the purposes of obtaining a licence. Therefore, Registrars shall engage such entities, whether they be business units, subsidiaries, or divisions, as distinct legal entities for the purpose of certification under CMDCAS. The applicability of certificates issued to a division shall be limited to that division. The name and address of parent companies or ownership groups may not appear on certificates, except where necessary to identify the legal name associated with the certified QMS. The following is an acceptable format: ABC, a division of XYZ - a wholly owned subsidiary of 123 Address or Company ABC, Medical Device Division Address 8 Revised Date: 2007/10/29; Effective Date: 2008/01/02

2.3.2 Two or More Manufacturer s Names on a Certificate In a situation where there is a singly defined QMS, associated with two or more names, the certificate may bear the additional names, subject to any verifications and/or certification requirements by the Registrar, including verifying the Manufacturer s intention to use all such names in Canada. The names will be listed in the following manner: Company X also trading as Company Y also trading as Company Z...etc. Address 2.4 Manufacturer s Address The certificate s main page, beneath the Manufacturer s name, shall identify the address to whom the certification applies (ISO 17021:2006 8.2.3 a); GD013/Rev00-MDB Item 4). The Manufacturer s address shall be the same as that used on the device licence and device label. A complete address would include a street name and number, city, province or state (where applicable), postal or zip code, and country. A post office box number may be added to the complete address. Address on the Certificate = Address on the Licence = Address on the Device Label 2.5 Multi-Site QMS Manufacturers are required to define the scope (extent and boundaries) of the QMS in their quality manual (ISO 13485:2003, 4.2.2 a)). The scope generally includes a description of the physical locations, organizational units, and processes. If more than one physical location is defined within the scope of the QMS, i.e., a multi-site organization, then the names and street addresses of the branch offices shall also be listed and identified as additional sites on the certificate, provided they are covered by the certification (ISO 17021:2006 8.2.3 a)). Additional addresses shall not confuse the main address. Where certificates display more than one scope statement (see below), Health Canada will record the global scope statement for regulatory purposes. The global scope statement shall adequately cover any site-specific scope statements and all generic device categories. Revised Date: 2007/10/29; Effective Date: 2008/01/02 9

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document NB1: Separate entities, such as subcontractors, that provide product to the Manufacturer's specifications, are not under the direct control of the certified QMS and thus shall not be listed on the certificate. NB2: Health Canada will not issue a device licence to a branch office. Only the Manufacturer, the central office of a multi-site, can obtain a licence. 2.6 Scope Statement For regulatory purposes, the certificate s scope statement consists of two components: QMS processes, including related services; and device listing. It is incumbent upon the Manufacturer to draft the initial scope statement (ISO 17021:2006 9.2.1). The finalized scope statement will be subject to clarifications, audit findings, and the Registrar s certification decision. (ISO 17021:2006 9.2.3.1.1 d)) Manufacturers and Registrars are strongly encouraged to employ the scope templates found in Appendix 1. 2.6.1 QMS Processes, Including Related Services A Manufacturer of a Class II device complies with MDR section 32(2)(f) by providing to Health Canada a copy of the quality management system certificate certifying that the quality management system under which the device is manufactured... A Manufacturer of a Class III or IV device complies with MDR sections 32(3)(j) or 32(4)(p) respectively by providing to Health Canada a copy of the quality management system certificate certifying that the quality management system under which the device is designed and manufactured... Thus, depending on the class of the device(s) involved, the scope statement will contain manufacture or design and manufacture. A certificate which lacks design in the scope statement that is submitted in relation to a Class III or IV device will not be accepted by Health Canada. A certificate which lacks manufacture in the scope statement, regardless of the device class involved, will not be accepted by Health Canada (see notes below). Additional QMS processes and services pertaining to the device may also be listed in the scope statement, but in most situations should be limited to QMS processes per ISO 13485:2003 (see ISO 13485:2003, 0.1). All processes listed in the scope statement will 10 Revised Date: 2007/10/29; Effective Date: 2008/01/02

be supported by evidence of conformity (ISO 17021:2006 9.2.3.2 a). Any listed processes outside the scope of ISO 13485:2003 shall be auditable and will have been carried out by audit teams possessing the necessary competence (ISO 17021:2006 7.2.7). Additional audit time will have been allocated and justified. NB1: Health Canada will not accept development in place of design (ISO 9000:2005 3.4.4). Design and development is acceptable. NB2: Health Canada considers manufacture and production to be interchangeable and thus use of either term is acceptable. 2.6.2 Device Listing All medical devices that are: manufactured or designed and manufactured under an ISO 13485:2003 QMS; and, licenced for sale or will be licenced for sale in Canada, shall be listed in the certificate s scope statement using generic device groups. Despite the use of generic device groups, the device descriptions shall be of sufficient detail such that there can be little to no reasonable doubt that the devices listed in the scope statement refer to the same device(s) in a licence application, renewal or amendment (the term accessories is not a generic device group). The templates in Appendix 1 cover a broad range of generic device groups. Other generic device groups may also be listed, such as Class I devices or devices that fall outside of the Food and Drugs Act definition but meet an ISO, or other national, or regional definition. In addition to being accurate and complete, the scope statement should be robust; that is, it should not have to be modified every time devices are added or removed from the generic device groups covered by the scope, or that a design or manufacturing change is made to one of the specific devices included in the groups. Consequently, the listing of product names, trade names, catalogue numbers, device licence numbers, or device classes in the scope statement is not permitted. Certificates bearing such information will not be accepted by Health Canada. Separate quality management system certificates for each component or member of a device family, group, group family, system and test kit will not be accepted by Health Canada. Revised Date: 2007/10/29; Effective Date: 2008/01/02 11

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document 2.7 Signing Authority A certificate shall be signed by an officer who is employed and authorized by the Health Canada recognized Registrar to perform that function (ISO 17021:2006, 5.1.3). The authorized person s name and position shall appear below or beside the signature. 2.8 Registrar s Name and Address The Registrar s name and address shall appear on the certificate and shall be the same as that of the accredited entity (ISO 17021:2006 5.1.1) or the directly recognized entity (MDR section 32.1). 2.9 QMS Standard Audited Against A certificate shall either reference ISO 13485:2003 or CAN/CSA-ISO 13485:03. Additional references to other QMS standards or other normative documents are permitted (ISO 17021:2006 8.2.3 e)) but not recommended. Additional scope statements arising from other standards shall not detract from the information required by Health Canada (see 2.6). 2.10 Record of Registrar s Recognition Registrars who are recognized by Health Canada through the accreditation and sector qualification process of the SCC shall make a claim on their certificates that they are CMDCAS recognized. The Registrar could use the phrase, Canadian Medical Devices Conformity Assessment System recognized Registrar or CMDCAS recognized Registrar. The statement of CMDCAS recognition is restricted to certificates intended for current Class II, III, or IV licence holders or Manufacturers intending to obtain licences. Registrars and Manufacturers shall not use any logos or symbols associated with the Canadian Federal Identity Program (http://www.tbs-sct.gc.ca/fip-pcim/index_e.asp) on their certificates (or other documentation). 2.11 Mark of Accreditation CMDCAS recognized Registrars shall display the SCC s mark of accreditation (ISO 17021:2006 8.2.3 g)). Additional marks from other accreditation bodies may also be displayed, where permitted. The use of such marks shall not be misleading and are subject to applicable laws, standards, agreements, etc. Registrars that are directly recognized by Health Canada under section 32.1 of the MDR will not display the SCC s mark of accreditation. 12 Revised Date: 2007/10/29; Effective Date: 2008/01/02

2.12 Format Manufacturers may be issued certificates in printed hard copy, faxed or electronic formats. For regulatory submissions, printed hard copy is the default format. Electronic format or fax submission is acceptable where Health Canada has specifically permitted or requested it. Where a certificate exceeds one North American letter size (8.5 11") or ISO A4 (210 297mm) page, additional pages may be utilized, but shall display the Registrar s name or logo, and any appropriate traceability information such as the certificate s unique identification code and page numbers. 2.13 Language As a minimum, the information Health Canada requires displayed on or attached to a certificate shall be in English or French. English-French bilingual format is acceptable. Although not recommended, information in languages other than English or French are permitted on the certificate. Multilingual certificates shall not confuse or contradict the essential information required by Health Canada. Revised Date: 2007/10/29; Effective Date: 2008/01/02 13

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document Appendix 1: Scope Statement Templates The MDR, which applies to all products that meet the definition of a medical device that is found in the Food and Drugs Act (R.S., C. F-27, S.1), categorizes medical devices as either in vitro diagnostic devices or devices other than in vitro diagnostics. There is a template for each type. i) Determine if the product is an in vitro diagnostic device or not, as this will dictate which of the two generic device group templates to use. If a Manufacturer will licence both types of devices, then they may use both templates and formulate a hybrid scope statement. ii) iii) Delete the QMS processes, generic device groups, and medical areas that do not apply. The list of generic device group descriptions provided in each template is not comprehensive. Other generic device group descriptions can be added if the ones provided are not adequate. Health Canada s Device Licensing Services Division may be contacted for assistance if a generic device group is not represented in the templates and a suitable one cannot be determined. 1. Template for in vitro Diagnostic Devices The (design and development,) manufacture, (installation, service) of (in-vitro diagnostic analyzers/software, in-vitro diagnostic medical devices, in-vitro diagnostic reagents, in-vitro diagnostic test kits) used in the (diagnosis, management, detection) of (autoimmune status, blood analytes, blood components, blood gases, blood grouping, cancer, cardiac markers, coagulation, compatibility testing, disease status, donor screening, drugs of abuse, endocrine disorders, fertility testing, genetic testing, immune status, pregnancy testing, prenatal screening, protein metabolism, sexually transmissible agents, tissue typing, transmissible agents, immunological typing, therapeutic drug monitoring, other... ) including (home use, near patient/point of care) in-vitro diagnostic devices. 2. Template for Devices other than in vitro Diagnostic Devices The (design and development,) manufacture, (installation, service) of (anaesthesia systems, anaesthetic and/or breathing adaptors, biliary stents, bone prostheses, breathing circuits, cardiovascular stents, catheters, cochlear implants, computed tomography scanners, condoms, contact lenses, cryosurgical instruments, defibrillators, dental amalgams, dental implants, dental etchants, dermatological lasers, diagnostic ultrasound systems, dilatation catheters, disposable surgical instruments, ECG monitors, ECG leads, EEG recorder, elastomeric pumps, electrosurgical instruments and generators, endoscopes, examination gloves, guide wires, hearing aids, hemodialysis water purification systems, imaging and monitoring workstations, 14 Revised Date: 2007/10/29; Effective Date: 2008/01/02

infusion pumps, intraocular lenses, intravenous infusion sets, irrigation/drainage sets, mechanical and tissue heart valves, nebulizers, needles, ophthalmic lasers, orthopaedic implants, pacemakers, patient monitors, Picture Archiving Computer Systems (PACS), powered dental instruments, pulse generators, resorbable material implants, slit lamps, software, surgical gloves, surgical sponges, surgical lasers, surgical trays, sutures, syringes, therapeutic ultrasound devices, tonometers, vascular introducers, ventilators, wound dressings, x-ray equipment, other...) for the area of (anaesthesiology, cardiovascular, dentistry, electrosurgical applications, ENT, gastroenterology, neurology, obstetrics & gynaecology, ophthalmology, orthopaedics, plastic surgery, radiology, urology). Revised Date: 2007/10/29; Effective Date: 2008/01/02 15

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document Appendix 2: Example Scope Statements The following are examples of acceptable and unacceptable scopes statements for in vitro diagnostic devices. Example A1 Manufacturer sells, or intends to sell, hand held chemistry and coagulation analysers. Unacceptable Scope Statement The development and commercialization of biosensor-based analytical systems. Reason for Unacceptability Design and manufacture are missing and the device description is too broad. Commercialization refers to the management of a for-profit entity, which is too generic to be associated with a QMS process. Acceptable Scope Statement The design and development, manufacture, service of in vitro diagnostic cartridges, controls, analyzers/software, used in the diagnosis and management of blood analytes, blood components, and coagulation including near patient in vitro diagnostic devices. Example A2 Manufacturer sells, or intends to sell, home pregnancy test kits and ovulation detection kits. Unacceptable Scope Statement The design and manufacture of IVDD's. Reason for Unacceptability The scope statement is too broad and ambiguous and does not specify the type of product or its intended use. Acceptable Scope Statement The design and manufacture of in vitro diagnostic test kits, used for the detection of pregnancy and ovulation including home use in vitro diagnostic devices. Example A3 Manufacturer sells, or intends to sell, the following Class II devices: anti-gbm (Glomerular Basement Membrane), Antibodies (ELISA) kit, Anti-PR3 Antibodies (ELISA) kit (Serine Protease-3), HP-G Screen H Pylori (IgG) Antibodies (ELISA), MPO Antibodies (ELISA) kit (Myelperoxidase). 16 Revised Date: 2007/10/29; Effective Date: 2008/01/02

Unacceptable Scope Statement The design and development, and manufacture of Class II "We-Test-It" in vitro diagnostic kits, Canadian Licence #'s 134567, 134568, 134569, 134570, 134571 for the detection of infectious and autoimmune disease. Reason for Unacceptability Scope statement includes the class of device, its brand name, and Health Canada assigned licence numbers. The scope statement does not include immune response to food tests. Acceptable Scope Statement The design and development, and manufacture of in vitro diagnostic kits for the detection of infectious and autoimmune disease, including immune responses to food. Example A4 The Manufacturer sells, or intends to sell, insulin dosers, lancets, lancing devices, consumer and hospital blood glucose monitoring systems, insulin delivery and blood glucose monitoring systems, control solutions, and test strips. Unacceptable Scope Statement Design and development, and manufacture of glucose monitors, test strips, and lancets. Reason for Unacceptability Scope statement does not cover all products presently licensed for sale in Canada or that are intended to be licensed for sale in Canada. Scope statement does not specify home and/or point of care use. Acceptable Scope Statement Design and development, manufacture and service of in vitro diagnostic devices used in the monitoring of blood glucose including lancets, lancing devices, control solutions and test strips including point of care and home use. The following are examples of acceptable and unacceptable scopes statements for devices that are not in vitro diagnostic devices. Example B1 Manufacturer sells, or intends to sell, synthetic surgical mesh, irrigation pumps, carbon dioxide pumps, electrosurgical electrodes, wound dressings, and infusion sets in Canada. Unacceptable Scope Statement The design and development and manufacture of electrosurgical electrodes, irrigation sets, infusion devices, and wound dressings. Revised Date: 2007/10/29; Effective Date: 2008/01/02 17

GD207: Guidance on the Content of ISO 13485 Quality Management System Certificates Issued Health Canada Guidance Document Reason for Unacceptability Scope statement does not cover synthetic surgical mesh or pumps Acceptable Scope Statement The design and development and manufacture of synthetic surgical mesh, powered irrigation sets, carbon dioxide and irrigation pumps, infusion sets, electrosurgical instruments, hemostatic and wound dressings. Example B2 Manufacturer sells, or intends to sell, install and service ultrasound systems, probes, Picture Archiving Computer Systems (PACS), and workstations. Unacceptable Scope Statement Design and development, manufacture of ultrasound systems. Reason for Unacceptability Scope statement does not cover probes, Picture Archiving Computer Systems (PACS) or workstations. Acceptable Scope Statement Design and development, manufacture, installation and service of ultrasound systems, probes, Picture Archiving Computer Systems (PACS), and ultrasound workstations. Example B3 Manufacturer sells, or intends to sell, sterile surgical gloves. Unacceptable Scope Statement The distribution of medical examination gloves. Reason for Unacceptability Scope statement does not include "manufacture" and uses incorrect generic device group medical examination gloves instead of sterile surgical gloves. Acceptable Scope Statement The manufacture of sterile surgical gloves. Example B4 Manufacturer is design responsible and sells, or intends to sell in Canada dental surface conditioners, dental cement, varnishes, restoration materials and implants. 18 Revised Date: 2007/10/29; Effective Date: 2008/01/02

Unacceptable Scope Statement The manufacture of dental restoration materials. Reason for Unacceptability Scope does not indicate design and it does not include all generic device groups. Acceptable Scope Statement The design and development and manufacture of dental restoration materials, dental implants and materials for restoring and protecting teeth in the area of dentistry. Revised Date: 2007/10/29; Effective Date: 2008/01/02 19