CONTRA COSTA COUNTY OPERATIONAL AREA POLICY POLICY#2

Similar documents
Fireground Safety System

San Mateo County Fire Service POLICIES AND STANDARDS MANUAL

LAKEWOOD FIRE DEPARTMENT STANDARD OPERATING GUIDELINES

Essex County Fire. Standard Operating Guideline

HORRY COUNTY FIRE RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING GUIDELINE. SOG 607 Live Fire Training in Acquired Structures

Cumberland County Standard Operating Guideline Order of Apparatus Arrival - Structural Fire Assignment

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING PROCEDURE

Monroe Fire Department

ESCAMBIA COUNTY FIRE-RESCUE Rules, Policies, and Guidelines Implemented: 02/23/2018 Revised: Paul Williams, Fire Chief Page 1 of 5

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL SAFETY

Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

INCIDENT COMMAND SYSTEM. Position Manual RAPID INTERVENTION GROUP SUPERVISOR HIGH RISE INCIDENT ICS-1006

FAUQUIER COUNTY FIRE RESCUE AND EMERGENCY MANAGEMENT

CONTRACOSTACOUNTY OPERATIONAL AREA POLICY #15

ACCOUNTABILITY. This guideline shall apply to all members of the Stoney Point Fire Department (SPFD) and shall be adhered to by all members.

San Mateo County Fire Service POLICIES AND STANDARDS MANUAL

MANDAN FIRE DEPARTMENT STANDARD OPERATION PROCEDURES

RAPID INTERVENTION TEAM (RIT) COMMAND AND OPERATIONAL PROCEDURES

Fire and Rescue Operations Chapter 20 Incident Management System (IMS) March 2009

COURSE OUTLINE Firefighting Tactics and Strategy

Active Shooter Guideline

Coldspring Excelsior Fire and Rescue Standard Operating Policies 6565 County Road 612 NE Kalkaska, MI Section 4.13 INCIDENT COMMAND MANAGEMENT

PROCEDURE MANUAL Code: Fire Services Command Procedures Original Date: 6/16/11 Revised Date: 8/24/11

PyroLance LLC. STANDARD OPERATING PROCEDURE

Sanoca Rural Fire District, Inc. STANDARD OPERATING PROCEDURES Emergency Operations

FIRE TACTICS AND PROCEDURES HAZARDOUS MATERIALS 12 October 19, 2005 TECHNICAL DECONTAMINATION TASK FORCES 1. INTRODUCTION

Niagara County Emergency Services

LIST OF EFFECTIVE PAGES. Cover Sheet 0 LEP 0 Table of Contents 0 4 thru 9 0. AG-009 Rev. 0 Page 2 of 19

Cumru Township Fire Department 4/27/2010 Standard Operating Guidelines Page: 1 of 13 Section 15.02

STANDARD OPERATING GUIDELINE Civil Disturbances

BURLINGTON COUNTY TECHNICAL RESCUE TASK FORCE OPERATING MANUAL

RIT Communications, Activities, and Deployments at Structural Fires

Westbrook Fire & Rescue Department Standard Operating Procedure

INCIDENT COMMAND STANDARD OPERATING GUIDELINE

Stillwater Fire District Stillwater, New York

CIVIL DISTURBANCE PROCEDURE

Model Policy. Active Shooter. Updated: April 2018 PURPOSE

Mosier Fire District

City of Folsom FY Final Budget

STANDARD OPERATING GUIDELINES

1.2 Ladder Companies in quarters with understaffed Engine Companies shall temporarily detail their 5th firefighter until arrival of ordered details.

Thank you for your interest in a career position with Anne Arundel County Fire Department.

Commack School District District-Wide. Emergency Response Plan

INCIDENT COMMAND SYSTEM HIGH RISE STRUCTURE FIRE OPERATIONAL SYSTEM DESCRIPTION ICS-HR-120-1

This replaces page, Section, Dated This is a new page

Big Sandy Fire Protection District/Simla Volunteer Fire Department Junior Firefighter Program Guidelines

Egg Harbor Fire Department and First Responders Standard Operating Guideline

Emergency Operations Plan

Vetting is defined as providing opportunities for examination, scrutinizing, testing and providing input.

INCIDENT SAFETY OFFICER NFPA 1521, Chapter 5, 2015 Edition

Oswego County EMS. Multiple-Casualty Incident Plan

Page 1 of 7 YALE UNIVERSITY POLICE DEPARTMENT PURSUIT AND EMERGENCY DRIVING GENERAL ORDER JAN 2012 ANNUAL

YORK COUNTY FIRE SCHOOL STRUCTURAL BURN BUILDING USAGE MANUAL

OKALOOSA COUNTY EMERGENCY MEDICAL SERVICES STANDARD OPERATING PROCEDURE Medical Incident Command Policy:

COUNTY FIRE CHIEFS ASSOCIATION GUIDELINES

City of Tuscaloosa Human Resource Department Class Code: 6023 Classification Specification Grade: 17 FLSA: Non-Exempt

ACTIVE SHOOTER GUIDEBOOK

GALENA FIRE DEPARTMENT INCIDENT COMMAND PROCEDURE MANUAL

Mercer County Fire Department Junior Firefighter Program 200 Morris Drive Harrodsburg, KY Phone (859) Standard Operating Procedures

GREEN SHEET. SACRAMENTO FIRE DEPARTMENT Informational Summary Report of Serious SFD Injuries, Illnesses, Accidents and Near-Miss Incidents

Arvin Hart Fire Company SOGs as revised: September of Facilities. Equipment and Apparatus

LAKE VALLEY FIRE PROTECTION DISTRICT JOB DESCRIPTION Apprentice Firefighter/Paramedic

SANTA CLARA COUNTY HIGH-RISE INCIDENT PLAN November 2001

Chelan & Douglas County Mass Casualty Incident Management Plan

Santa Monica Police Department

Fire Captain (2142) Task List

Town Of Waterbury. Fire Department. Title: INTRODUCTION - PURPOSE, PHILOSOPHY, OBJECTIVES. Number: 100. Standard Operating Guideline

KING COUNTY FIRE MODEL PROCEDURE Section 10 Personnel Accountability

Mass Casualty Incident (MCI)

THE INCIDENT COMMAND SYSTEM ORGANIZATION

on the Sharonville Fire Department

Primary Classes Professional Development Series IS 100 Incident Command System IS 200 Single Resources and Initial Action Incidents

INCIDENT COMMAND SYSTEM. Position Manual STAGING AREA MANAGER- HIGH RISE INCIDENT ICS-1003

Read the scenario below, and refer to it to answer questions 1 through 13.

Chanhassen Fire Department

Teacher Assessment Blueprint

INCIDENT COMMMAND. B. Improve the use of resources and tactical effectiveness.

Respiratory Protection: What Employers and Supervisors Need to Know. December 6, 2016

Sacramento Fire Department. Shasta Burn. Incident Action Plan

ACTIVE SHOOTER HOW TO RESPOND

D E T R O I T P O L I C E D E PA R T M E N T

Emergency Operations Plan

ACTIVE SHOOTER HOW TO RESPOND. U.S. Department of Homeland Security. Washington, DC

Presentation to the Putnam County Fire Chiefs Association

UNIVERSITY OF TOLEDO

Incident Command-Incident Management Plan

EMERGENCY RESPONSE AND EVACUATION PROCEDURES STATEMENT

MEDICAL UNIVERSITY OF SOUTH CAROLINA DEPARTMENT OF PUBLIC SAFETY. EFFECTIVE DATE: 1 January 1999 PAGE 1 OF 10

Thurston County Technical Rescue Response Mobilization Plan and Operating Guidelines

2018 Volunteer Week at Florida State Fire College April 25-29, Course Descriptions

ESCAMBIA COUNTY FIRE-RESCUE

Staging Board Procedures. Supersedes: 8/27/01 (New) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

WHAT IS AN EMERGENCY? WHY IT IS IMPORTANT TO PREPARE COMMUNICATIONS

Cortland County. Department of Fire and Emergency Management. Fire / EMS. Mass Casualty Incident MCI Plan

Integrated Safe School Plan. Emergency Team Duties and Supply Lists. Incident Command System

Niagara County Emergency Services

Mandatory School Safety Plans Practical Considerations

MINIMUM OPERATING SECURITY STANDARDS (MOSS) FOR UN AGENCIES IN THE DOMINICAN REPUBLIC JUNE 2010

GREY NUNS COMMUNITY HOSPITAL ACTIVE ASSAILANT EMERGENCY RESPONSE PLAN

Evendale Fire Department Procedures Manual

Transcription:

CONTRA COSTA COUNTY OPERATIONAL AREA POLICY POLICY#2 TOPIC: Rapid Intervention Crew (RIC) Revision Date February 2011 Replaces July 2008 DISPOSITION: Operational Area Policy Manual Approved By County Chiefs Pages 5 INTRODUCTION: Firefighters, who are lost, trapped, or missing, may have only minutes to receive help before their chances for survival drop dramatically. The failure to pre-plan and preposition personnel and equipment prior to a fireground emergency may delay or prevent a successful outcome. A Rapid Intervention Crew (RIC) is a resource immediately available to the Incident Commander (IC) for the primary purpose of firefighter rescue. The establishment of a RIC is a critical step toward increasing the survivability of a firefighter who becomes lost, trapped, or incapacitated. The purpose of this policy is to identify the role, responsibilities, and requirements for the establishment and use of a Rapid Intervention Crew (RIC) by County fire service agencies. POLICY: A. Establishing a Rapid Intervention Crew 1. A RIC shall be established whenever personnel are operating in a hazardous area, an Immediately Dangerous to Life and Health (IDLH) atmosphere, or anytime the Incident Commander deems it appropriate. 2. The IC shall be responsible for establishing a RIC. 3. On incidents where a Two-Out Team is established, the IC or designee shall transition from the Two-Out Team to a RIC as soon as possible and practical. 4. When adequate resources are available and conditions warrant the assignment, a RIC should be established immediately, and this will satisfy the requirement for Two-in/Two-out.

5. The factors that determine when multiple RIC s are assigned or deployed are incident-driven. As the incident expands in size or complexity, the IC may opt to assign multiple companies to rapid intervention by establishing a RIC Group. 6. Once a company has been assigned as a RIC, the IC should avoid reassigning them to other tasks that restrict their ability to respond to a fireground emergency. 7. The IC should avoid transferring the assignment of RIC from the initially assigned company to other companies whenever possible to avoid any loss of critical safety information. 8. The RIC function shall continue until the incident has concluded or the IC determines, that based on a hazard assessment, the RIC is no longer needed. Consideration shall be given to keeping the RIC operational in cases where active fire suppression operations have ceased, yet overhaul operations or other activities are being conducted in areas with potential hazards. B. Rapid Intervention Crew Operations 1. The RIC shall don full protective equipment with SCBA, handlights, and portable radios. 2. The RIC Officer shall report to the IC or designated supervisor for a briefing on the incident. The briefing should include; Incident objectives, strategy, and tactics Current assignment of crews and their probable location Building information Known hazards Designation of the initial RIC staging area 3. If a Two-Out Team has been established prior to the RIC, the RIC Officer shall contact the Two-Out Team for a briefing and transfer of responsibilities. 4. The RIC shall conduct a size-up of the structure/incident, to identify construction features and potential hazards. Immediate or subsequent actions may include: Requesting additional resources Providing ladders needed for emergency egress from windows, and/or roof Coordinating the opening of doors and windows, security bars/devices Illuminating entrances and exits. 2

5. The size-up shall include consulting with firefighters, occupants, and property owners to determine what is occurring at the incident. The RIC shall attempt to identify: Areas of involvement and fire conditions Specific hazards Location of personnel Other pertinent information 6. To clearly identify the RIC staging area and prevent use by other firefighters, the RIC shall deploy their equipment on a readily identifiable RIC Tarp. 7. The following equipment (at a minimum) should be assembled and ready for immediate use by the RIC: Flathead axe Halligan tool Bolt cutters 10 lb. sledgehammer Trauma scissors Wire cutters Chain saw 100 3/8 inch RIC rope bag Thermal imaging camera and spare battery (if available) RIC Bag (or spare SCBA, facepiece, and regulator) (4) Door chocks Any other equipment deemed necessary 8. The RIC size-up should include an evaluation of whether or not deploying a charged or uncharged hoseline for RIC operations is appropriate for the situation. 9. Following the RIC size-up, initial rescue concerns should be identified and an incident specific rapid intervention plan shall be developed. Additional and/or specialized equipment shall be considered based on information gathered; the list of tools is limited only by your situational needs. 10. The primary objective of the RIC is to standby as a team in a state of constant readiness, maintaining situational awareness, ready to react to any firefighter emergencies. Stay focused on the assignment the most important one on the fireground. C. Accountability 1. All RIC members shall have a portable radio and will carefully monitor the assigned tactical channel(s) and dispatch channel. 2. At least one member of the RIC shall be responsible for maintaining a constant awareness of the Entry Teams operating in an IDLH atmosphere or hazard area, their location, and function. 3

D. Activation of the RIC 1. The IC or designee should clear the tactical channel by announcing Emergency Traffic. 2. The IC or designee and the RIC Officer shall obtain as much information as possible about the fireground emergency, including the location, type of problem, and number of firefighters involved. 3. The IC shall request an additional tactical channel(s) from the Communications Center and move the incident operations to the new channel. 4. The RIC shall utilize the original tactical channel to conduct rapid intervention operations and communicate with personnel needing rescue. 5. The IC shall ensure that a PAR is conducted as soon as possible after moving the operations to the new tactical channel. 6. The IC will ensure that all tactical channels utilized at the incident are monitored at the Incident Command Post. 7. The IC shall evaluate the need for additional resources to mitigate both the fireground emergency and the initial incident. Consideration should be given to requesting (1) ALS ambulance for each firefighter who is lost, trapped, or missing. 8. Additional RIC(s) should be established to assemble necessary tools and equipment to support the operation and to relieve the initial RIC as needed. These additional RIC(s) may be assigned to initiate rescue operations from a secondary access point. E. Incident Review and Documentation 1. All circumstances related to RIC assignments shall be documented. 2. The Incident Commander shall conduct a post incident analysis with personnel involved when a RIC is activated. F. Definitions 1. Emergency Traffic A term used to clear the designated radio channel(s) used at an incident to make way for critical radio traffic. It is used for Firefighter Emergencies, Imminent Hazard Notification, and Operational Retreat procedures. It is standard terminology used by the fire service in the State of California. 2. Entry Team A team of two or more firefighters who enter an IDLH environment to conduct firefighting operations. 4

3. IDLH (Immediately Dangerous to Life and Health) Environment An atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual s ability to escape from a dangerous atmosphere. Any structural fire beyond the incipient stage is considered by OSHA to be an IDLH atmosphere. 4. Incipient Fire The initial or beginning stage of a fire which can be controlled by portable fire extinguishers, Class II standpipe, or small hose systems without the need for protective clothing or SCBA. 5. PAR A roll call procedure initiated by Command to confirm that all personnel assigned to an emergency incident are physically accounted for. 6. Rapid Intervention Crew (RIC) A dedicated company of three or more firefighters who are assigned for rapid deployment to rescue firefighters. 7. Two-Out Team (Two-Out) A team of two firefighters present outside the IDLH atmosphere in the initial stage of a structural fire attack; required to be established prior to interior operations by the Entry Team in an IDLH atmosphere. The Two-Out Team shall be properly equipped to initiate rescue. 5