Life Safety Code Update for Hospitals and Nursing Homes May 3, 2012

Similar documents
New Fire Safety Rules Summary Evvie Munley, LeadingAge

Department of Health Update

Facility Demographic Report

Prepublication Requirements

Adult Family Care Home Top Ten Health Deficiency Citations Statewide October 8, 2009 Year Date Range: January 1, 2008 through December 31, 2008

How to Submit Waivers and Equivalencies

Minnesota Health Care Engineers Association. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

SENIOR/ASSISTED LIVING FACILITY SPECIFIC QUESTIONNAIRE

F Physical Environment The facility must be designed, constructed, equipped, and maintained to protect the health and safety of residents,

The Healthcare Environment Challenges and Update

ND CAH Quality Pre-Conference

Report to the General Assembly: Nursing Home Inspection and Enforcement Activities. A Report to the 105 th Tennessee General Assembly

The Pre-Construction Risk Assessment

EXISTING CONDITIONS

Joint Commission Resources Quality & Safety Network (JCRQSN)

Center for Medicaid, CHIP, and Survey & Certification/Survey & Certification Group

CALIFORNIA STATE UNIVERSITY, OFFICE OF THE CHANCELLOR Telecommuting Policy and Guidelines For CSUEU Employees

Facility Information. Overview of Visit. Report Summary

245D-HCBS Community Residential Setting (CRS) Licensing Checklist

SUBCHAPTER 31. MANDATORY PHYSICAL ENVIRONMENT

1 What is an AAAHC/Medicare Deemed Status survey? 2 What are the Medicare Conditions for Coverage (CfC)?

M E M O R A N D U M. NFPA Technical Committee on Health Care Occupancies. Diane Matthews, Project Administrator

TOP 10 DEFICIENCIES, SECOND QUARTER FY 2015.xls

Agency for Health Care Administration. December 4, 2008

Standards. Successfully Preparing for Your Next AAAHC Accreditation Survey Annual Conference

Preparing for Life Safety Code Surveys with the Joint Commission - Part 2. Florida Hospital Association. Wednesday, May 2, 2018 WELCOME!

DHS 83 Question & Answer Document (related to revisions made effective ) SUBCHAPTER I LICENSING: DHS DHS 83.03

Health Care Construction Projects

2018 Program Review and Certification Standards J. Facilities

HOLLAND HOUSE SCHOOL 11 - HEALTH, SAFETY AND SECURITY POLICY

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE

RULES OF TENNESSEE DEPARTMENT OF MENTAL HEALTH AND MENTAL RETARDATION CHAPTER ADEQUACY OF FACILITY ENVIRONMENT AND ANCILLARY SERVICES

University of Akron College of Nursing 370-Care of Older Adult Home Safety Checklist

E63-09/ (IFC [B] )

Alabama Medicaid Adult Day Health Minimum Standards

Celebrating Aging in Arkansas

Overview of the CMS Emergency Preparedness Final Rule

Emergency Preparedness Requirements

GRILLS MODEL MWG-9501 MODEL MWGH-9501 MODEL MWGF-9501 MODEL MWGL-9501 MODEL MWGR-9501 WIRING DIAGRAMS

Navigating the Codes in Henry Kosarzycki, A.I.A. Architect/State Fire Authority September 12, 2013

Manhattan Fire Protection District

Rule R Nursing Facility Construction. Table of Contents. State Links: Utah.gov State Online Services Agency List Business.utah.gov Search.

HCBS Settings Evaluation Tool Module 3. Welcome

Agency for Health Care Administration

West Virginia. Phone. Agency (304)

Iowa. Phone. Web Site. Licensure Term

LIGATURE RISKS/MITIGATION STRATEGIES by Debra McGuire, MSN, RN Executive Director Psychiatry

Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY. 1 WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM August 2010 eere.energy.

District of Columbia. Phone. Agency. Department of Health, Health Regulation and Licensing Administration (202)

Niagara County Emergency Services

By now, everyone should be very familiar with the H&S Guidance contained in WPN For that reason, we won t review the entire WPN 17-7, but just

Department of Health and Human Services, Division of Public and Behavioral Health, Bureau of Health Care Quality and Compliance

Head Start Facilities and Safe Environments Checklist

4/3/2018. Nursing Facility Changes to Conditions of Participation (& Enforcement): What You Need to Know. Revisions to State Operations Manual

DODEA ADMINISTRATIVE INSTRUCTION DODEA SAFETY PROGRAM

Preparing for Life Safety Code Surveys with the Joint Commission - Part 1. Florida Hospital Association. Thursday, April 26, 2018 WELCOME!

APPENDIX I HOSPICE INPATIENT FACILITY (HIF)

CALIFORNIA STATE UNIVERSITY, BAKERSFIELD Office of Human Resources

CMS Proposed Rule

Subpart E. RESIDENTIAL AGENCIES/FACILITIES/SERVICES I. LICENSING/APPROVAL ARTICLE I. LICENSING/APPROVAL

TRENDING IN THE JOINT COMMISSION

Emergency Preparedness

Choosing Choosing Choosing Guide to Choosing a Nursing Home Choosing Choosing Choosing

HORRY COUNTY FIRE RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING GUIDELINE. SOG 607 Live Fire Training in Acquired Structures

PyroLance LLC. STANDARD OPERATING PROCEDURE

Basic Personal and Environmental Safety Precautions

19 Mo. Code of State Regulations CSR Definitions

Medicare Conditions for Coverage 2009 Crosswalk

MINUTES HEALTHCARE INTERPRETATIONS TASK FORCE

VIRGINIA AVENUE PARK CAMPUS Meeting Room Policy

Audio Title: Revised and Clarified Place of Service (POS) Coding Instructions Audio Date: 6/3/2015 Run Time: 16:03 Minutes ICN:

Medicare and Medicaid Program; Regulatory Provisions to Promote Program Efficiency, Transparency, and Burden Reduction. Summary of Proposed Rule

HCBS Settings Rule and Minnesota s Transition Plan

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

Keio University Tsunashima SST International Dormitory Regulations. As of

Marion County Public Library System Policy # 4 Meeting Room Policy

Observations for all areas: What type of supervision is provided to the resident and by whom? How are care-planned interventions implemented?

Recommended Physical Plant Improvements to Existing Nursing Homes for Disaster Preparedness. Report to the Governor and to the Legislature

QUALITY ASSURANCE REVIEW CHECKLIST

LESSON ASSIGNMENT. Environmental Health and the Practical Nurse. After completing this lesson, you should be able to:

Health and Safety Policy

Cheryl Johnson, HFE NEII

MEDICARE/MEDICAID CERTIFICATION AND TRANSMITTAL. PART I - TO BE COMPLETED BY THE STATE SURVEY AGENCY Facility ID: 00940

Healthcare Life Safety Compliance

MEDICAL UNIVERSITY OF SOUTH CAROLINA DEPARTMENT OF PUBLIC SAFETY. EFFECTIVE DATE: 1 January 1999 PAGE 1 OF 10

Indiana Family and Social Services Administration Division of Aging Provider Approval Request For Agency Providers of Adult Day Services

THE HEALTHCARE ENVIRONMENT

HORRY COUNTY FIRE/RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING PROCEDURE SOP 202 SHIFT MANAGEMENT

BYRCHALL HIGH SCHOOL

Date: September 2, Assisted Living Facilities (ALFs) To:

THE HEALTHCARE ENVIRONMENT

GUILD LOUNGE RESERVATION POLICY

CHAPTER 3800 CHILD RESIDENTIAL AND DAY TREATMENT FACILITIES

Standard EC Elements of Performance for EC The hospital manages fire risks.

HOST HOME PROVIDER APPLICATION

Health and Safety general policy statement (Whole School including EYFS)

Michigan Statewide Home & Community Based Settings Transition Plan

Is your ward dementia-friendly? The EHE Environmental Assessment Tool

Wisconsin. Phone. Agency Department of Health Services, Division of Quality Assurance, Bureau of Assisted Living (608)

YORK COUNTY FIRE SCHOOL STRUCTURAL BURN BUILDING USAGE MANUAL

Transcription:

Life Safety Code Update for Hospitals and Nursing Homes May 3, 2012

James P. Loveland, P.E. Program Manager Minnesota Department of Health Engineering Services Section

The Centers for Medicare and Medicaid Services (CMS) has made the first significant move in adopting the 2012 edition of National Fire Protection Association (NFPA) Standard 101 (Life Safety Code, 2012 edition)

In response to pressure from some influential national organizations, CMS is permitting certified health care facilities to comply with the 2012 edition of the LSC in four (4) specific areas

This includes both hospitals and nursing homes

On March 9, 2012, CMS issued S&C-12-21-LSC. This memorandum allows: 1) previously restricted items to be placed in exit corridors; 2) the recognition that a kitchen is not a hazardous area and can be open to an exit corridor under certain circumstances;

3) changes allowing the installation of direct-vent gas fireplaces and solid fuel-burning fireplaces; and 4) changes to the requirements allowing the installation of combustible decorations

These changes include 1) permitting permanent seating groupings of furniture in corridors; 2) allowing kitchens, serving less than 30 residents, to be open to the corridors provided they are contained within smoke compartments;

3) permitting gas fireplaces in common areas, and; 4) increasing the amount of wall space that may be covered by combustible decorations

This memorandum is effective immediately. CMS will allow providers to implement these four changes by considering waivers of the current LSC requirements found in the 2000 edition of the LSC

In requesting the waiver(s), the provider is not required to demonstrate unreasonable hardship

CMS will consider a waiver to allow uses that meet the following requirements found in the 2012 edition of the LSC: Sections 18/19.2.3 Capacity of Means of Egress Sections 18/19.3.2.5 Cooking Facilities

Sections 18/19.5.2 Heating, Ventilating, and Air Conditioning Sections 18/19.7.5 Furnishings, Mattresses, and Decorations

All further references to the Life Safety Code are references to the 2012 edition of that Code.

FURNITURE AND WHEELED EQUIPMENT IN THE CORRIDOR

No changes were made to the Corridor Access provisions at 18/19.2.5.6.1 that requires every habitable room shall have an exit access door leading directly to an exit access corridor, unless otherwise provided

Also, previous guidance concerning not in use criteria found in S&C-10-18-LSC is still applicable According to S&C-10-18-LSC, an item is considered not in use if it is left unattended or is not moved for more than 30 minutes

It is recommended that each facility that is considering using the applicable provisions of this newer edition of the LSC purchase a copy of the 2012 edition The list of requirements under the Sections previously noted is, in some cases, extensive

CMS has advised MDH that the requirements of the health care Data Tags (F-Tags and A-Tags) have not changed THIS IS EXTREMELY IMPORTANT TO REMEMBER WHEN CONSIDERING USE OF THESE NEW PROVISIONS OF THE LSC

Regardless of having an approved waiver for provisions of the LSC, the provider is still required to meet all of the needs of their residents or patients

For example, Data Tag 468 requires handrails securely mounted on both sides of the corridors. Data Tag F323 addresses access to these handrails

Data Tag F-323 requires the facility to ensure that the resident environment remains as free from accident hazards as is possible and that each resident receives adequate supervision and assistance devices to prevent accidents. Handrails are assistive devices

Obviously, the furniture clusters in the corridors, now permitted by a LSC waiver, can still result in the facility being cited at Data Tag F-323

This approach is very similar to the gasfired fireplace. Although permitted by the LSC, the facility maintains responsibility for assuring that residents are not injured by having access to these very hot appliances

When considering the permanent placement of furniture in the corridor, the provider may want to consider how they will meet the needs of all of their residents (e.g. mobility, etc.)

Please keep in mind that the positive side of placing furniture in the corridor can help residents achieve the highest practicable level of health and well being.

DIRECT-VENT GAS AND SOLID FUEL-BURNING FIREPLACES (LSC 18/19.5.2)

Direct-vent gas fireplaces, as defined in NFPA 54, National Fuel Gas Code, are permitted inside smoke compartments containing sleeping areas provided that all of six (6) criteria are met

Solid fuel-burning fire places are permitted and can be used only in areas other than patient sleeping areas provided that all of four (4) conditions are met

The exact location of smoke partitions has a great deal of influence regarding where these fireplaces can be located relative to resident or patient sleeping rooms. Each installation must be reviewed on an individual basis

Much like the furniture in the corridor issue, the requirements of the health care Data tags (F-tags and A-tags) have not changed

In this case, there is anecdotal evidence that health care deficiencies have been cited at the immediate jeopardy level These deficiencies are related to resident or patient safety

Generally, a protective barrier is required at the front of these fireplaces to prevent access to any of the hot surfaces

FURNISHINGS, MATTRESSES, AND DECORATIONS (LSC 18/19.7.5)

18/19.7.5 through 18/19.7.5.6 details requirements that relate to draperies, curtains, loosely hanging fabrics, upholstered furniture, mattresses, and decorations

There are specific exemptions for upholstered furniture and mattresses that belong to the resident of a nursing home

COOKING FACILITIES (LSC, 18/19.3.2.5)

LSC 18/19.3.2.5.2 states; Where residential cooking equipment is used for food warming or limited cooking, the equipment shall not be required to be protected in accordance with 9.2.3, and the presence of the equipment shall not require the area to be protected as a hazardous area

9.2.3 states (in part); Commercial cooking equipment shall be in accordance with NFPA 96 (11), unless such installations are approved existing installations, which shall be permitted to be continued in service

If required to be protected as a hazardous area, this kitchen would require fire sprinkler protection and 1-hour fire resistive rated separation

The key words in 18/19.3.2.5.2 are for food warming or limited cooking

18/19.3.2.5.3 states; Within a smoke compartment, where residential or commercial cooking equipment is used to prepare meals for 30 or fewer persons, one cooking facility shall be permitted to be open to the corridor, provided that all of the following conditions are met:

18/19.3.2.5.4 states; Within a smoke compartment, residential or commercial cooking equipment that is used to prepare meals for 30 or fewer persons shall be permitted, provided that the cooking facility complies with all of the following conditions:

I read these two (2) sections to address multiple cooking facilities within one smoke compartment. This is not common in Minnesota. If there are multiple cooking facilities, only one is permitted to be open to the corridor

18/19.3.2.5.3 lists thirteen specific conditions including (but not limited to), smoke barrier separation, installation of a range hood (covering 100% of the range cooking surface, with baffles or equivalent, and minimum 500 cfm airflow), fire suppression system (UL300 or UL300A), range power deactivation switch, smoke detectors, and sprinkler protection

18/19.3.2.5.4 lists three specific conditions including (but not limited to), no cooking equipment in a sleeping room, separation IAW 18/19.3.6.2 through 18/19.3.6.5, and compliance with 18/19.3.2.5.3 (1) through (10) and (13)

Finally, 18/19.3.2.5.5 states; Where cooking facilities are protected IAW 9.2.3 (Commercial Cooking Equipment), the presence of the cooking equipment shall not cause the room or space housing the equipment to be classified as a hazardous area with respect to the requirement of 18/19.3.2.1 (Hazardous Areas) and the room or space shall NOT be permitted to be open to the corridor (emphasis added)

From a practical perspective, what does this all mean??

MDH believes that, 18/19.3.2.5.2 permits a facility to continue to follow the guidance in MDH Information Bulletin 11-06. Specifically, the cooking of the seven (7) food items listed in I.B. 11-06 with no production of grease laden vapors can be considered limited cooking

If a facility wants to expand cooking beyond that permitted by I.B. 11-06, 18/19.3.2.5.3 and 18/19.3.2.5.4 are applicable

Both 18/19.3.2.5.3 and 18/19.3.2.5.4 require a range hood with a UL 300 or UL 300A automatic fire extinguishment system. Given the additional requirements for the hood, it most likely will have to be a commercial grade Type I hood

If the cooking will result in the production of grease laden vapors, the State Building Code requires a commercial grade Type I hood (International Mechanical Code (06), 507.2)

MDH has been advised that conversion from a residential grade range hood to a commercial grade Type I hood with an automatic extinguishment system costs approximately $11,000 per location

It is critical to understand that the deficiency will not be cited until the range hood, automatic extinguishment system, and all other requirements listed in, 18/19.3.2.5.3 and 18/19.3.2.5.4 have been installed

Once the waiver has been approved by CMS, it is our belief that there are no restrictions regarding cooking various food items, including those that result in the production of grease laden vapors

For example, it would be acceptable to fry a raw hamburger or two for a resident who requests these food items for lunch rather than what is on the published menu

https://www.cms.gov/medicare/provider- Enrollment-and- Certification/SurveyCertificationGenInfo/Po licy-and-memos-to-states-and-regions.html

www.cms.gov MEDICARE (left side of home page) Under heading PROVIDER ENROLLMENT & CERTIFICATION (middle of right hand column), LT click on SURVEY & CERTIFICATION - GENERAL INFORMATION In the box on the left side of the page, click on POLICY & MEMOS TO STATES AND REGIONS Under MEMO #, search for 10-18-LSC and 12-21-LSC

Now for some FUN; ANY QUESTIONS???