The CMC Process; Submission of CMCs. By Ian Veldman AFRIMET AUV Chairman

Similar documents
Meeting at BIPM, Paris Friday 15 June 2012 at 9: 00 till 13:00 Lunch: 13:00. NMI TC Representatives KEBS Mr Anderson Maina

RECOMMENDATIONS FOR ON-SITE VISITS BY PEERS AND SELECTION CRITERIA FOR ON-SITE VISIT PEER REVIEWERS

Measurement Units, Standards and Services Department (MUSSD)- National Metrology Institute Sri Lanka. Time and Frequency Related Activities

ACCREDITATION REQUIREMENTS

Presentation prepared by the BIML Director on BIML BIPM cooperation activities

EURAMET Report for 50th CIML meeting October 2015

Accreditation of Clinical Laboratories

APMP/TCFF Meeting. Sep , 2014 Yong Moon Choi, TCFF Chair 유동음향센터 : 최해만

MINUTES OF THE 13th SADCMET COMMITTEE MEETING HELD AT THE GRAND PALM HOTEL, GABORONE, BOTSWANA 22 APRIL 2009

For Client Labs Purpose This document specifies the general requirements for the calibrations performed on Test and Measurement Equipment.

Bureau International des Poids et Mesures Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV)

Calibration Certificate Analysis

supplementary criteria for GLP registration

Guide 2: Submitting a Potential Research Topic or Potential Network Topic

Frequently Asked Questions (FAQs) regarding ISO/IEC 17025:2017 and the transition of accreditation from the previous version of the Standard

PRACTICAL APPLICATION OF ISO BY ACCREDITATION BODIES - A comparison with ISO/IEC Page 128. ejifcc2004vol15no4pp

Looking to the Future of European Metrology

SIM Council Meeting Washington USA Administration Building (101) Room A200 - NIST March 12 th and 13 th, 2007

Practical application of ISO by accreditation bodies A comparison with ISO/IEC 17025

The route to signing the IAF/ILAC Arrangement. Good Practice Guidelines for Single Accreditation Bodies

DOD MANUAL DOD ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (ELAP)

Medical Supply Co. Ltd.

Slovenian legal metrology in the field of health

Accreditation Application Verification

CNAS-RL01. Rules for the Accreditation of Laboratories

SANAS Report. No 98, August/September PRESENTATION OF NEW LOGO s MPHO PHALOANE Senior Manager: Mechanical and Physical

Accreditation Procedure

Clinical Appropriateness Guidelines

MEDICAL LABORATORIES - REQUIREMENTS FOR ACCREDITATION ACCORDING TO SM SR EN ISO 15189:2014

SIM COUNCIL MEETING Thursday 2 nd, April, 2009 Organization of American States (OAS) Washington DC, USA ATTENDENCE LIST COUNCIL MEMBERS

CNAS-R01. Rules for the Use of Accreditation Symbols and Reference to Accreditation

Procedure for Joint and Concurrent Evaluations by APLAC and PAC

EA Cross Border Accreditation. Policy and Procedure for. Cross Border Cooperation. Between EA Members

PGDs are permitted for use only by registered health professionals (see enclosed link for full list

(Experience of BSN-Indonesia)

Test report no.: Plug and key - Salt spray test

DEPARTMENT OF LABOUR TR 84-03

RD SOP12 Research Passport Honorary Contracts / Letters of Access

NZS/ISO 15189:2007. Medical Laboratories Particular Requirements for Quality and Competence NZS/ISO 15189:2007

Implementing Metrology in the European Research Area the imera Project

IS YOUR QAPI COP READY?

Northern Ireland Practice and Education Council. for Nursing and Midwifery. Recording Care PACE Care Planning Spread Plan

IAF MLA Document. Policies and Procedures for a MLA on the Level of Single Accreditation Bodies and on the Level of Regional Accreditation Groups

Why do we credential practitioners?

EL_07_04_07_218

APLAC. contents. Accreditation body news. NEWS NOTES No. 94 MARCH APLAC News Notes

CONTINUING EDUCATION AGREEMENT. OPTION A Agency will pay an annual Program Review Fee to the College of Nursing in the amount of $250.

Guide 1: Admissibility and Eligibility for EMPIR Calls

Trauma Verification Q&A Web Conference

Request for Proposals (US DOT FY 2016) Mid-America Transportation Center. United States Department of Transportation

December 2003-APL. All activities of BLQS, DMSc and the accredited laboratory directory are available on the website

SIM MWG- 9 Mee*ng. held at INMETRO 10 th November 2017

Le Moyne College. BEICKERT AUDIO 219 Arnold Ave, Syracuse, NY Thomas J. Niland Jr. Athletic Complex SOUND STUDY QUOTATION.

10 th European Development Fund (EDF) Programme. Technical Barriers to Trade

Local Care Planning Roles and Responsibilities

AC291 Special Inspection Agencies ACCREDITATION CRITERIA FOR IBC SPECIAL INSPECTION AGENCIES AC291

IECEx OPERATIONAL DOCUMENT

Professional Experience Placement Risk Management Procedure

American Horticultural Therapy Strategic Plan Association March 2015-March , 2, and 3 year plan

OA08 ACCREDITED BODIES' REPORTING. Table of contents

PATHWAYS FOR STANDARDS DEVELOPMENT. Developing internationally aligned Australian Standards in the national interest

SADCMET/MEL LM Report 19 June Presented by: Victor R Mundembe

NATA procedures for accreditation

Review Date: 6/22/17. Page 1 of 5

Construction Manager Qualifications Supplement (CMQS)

South Yorkshire and Bassetlaw NHS Footprint. Divert Policy July 2013

CONTINUING PROFESSIONAL DEVELOPMENT (CPD) FOR DENTAL CARE PROFESSIONALS GENERAL DENTAL COUNCIL

Information Technology Procurement Guidelines

Specific Accreditation Criteria Human Pathology. NATA/RCPA accreditation surveillance model for Human Pathology

Instructions: Please tick an appropriate response for each assessment criteria using the following scale below:

GUIDELINES ON CAEP PROGRAM REVIEW WITH FEEDBACK [2018] INITIAL LICENSURE PROGRAMS

TRUST CORPORATE POLICY RESPONDING TO DEATHS

POLICIES & PROCEDURES

NATIONAL LOTTERY DISTRIBUTION TRUST FUND (NLDTF) SPORT AND RECREATION SECTOR 2010 GUIDELINES AND INFORMATION REQUIRED

EFFECTIVE DATE: 10/04. SUBJECT: Primary Care Nurse Practitioners SECTION: CREDENTIALING POLICY NUMBER: CR-31

Instructions for Submission: Pilot Grant Applications National Multiple Sclerosis Society 2018

British Society for Surgery of the Hand. (BSSH) Evidence for Surgical

All areas of the Trust All Trust staff All Patients Deputy Chief Nurse & Chief Pharmacist Final

The Critical Reagents Program s Quality Initiatives. Critical Reagents Program (CRP)

POLICY & PROCEDURES FOR SUPERVISION IN NURSING. February Using Bedrails Safely and Effectively Policy Page 1 of 21

Department of Defense INSTRUCTION. SUBJECT: Implementation of Data Collection, Development, and Management for Strategic Analyses

Applicable Standards and Improvement Efforts. Preconference Workshop June 1, State Hygienic Laboratory, University of Iowa b

TC 100 Guidelines and Procedures

NEW MEXICO DEPARTMENT OF HEALTH DEVELOPMENTAL DISABILITIES SUPPORTS DIVISION MEDICALLY FRAGILE WAIVER (MFW)

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

Appendix L: Economic modelling for Parkinson s disease nurse specialist care

Standard INAB. The. World Accreditation Day Accreditation - Delivering a Safer World

Time Span Codes Policy

POLICY AND PROCEDURE FOR SUPERVISION IN NURSING IN [ORGANISATION]

Whatsup CONTENTS. Newsletter of the South African National Accreditation System. December 2017

Information Note for Training Incentives: IBF Standards Training Scheme (IBF-STS) & Financial Training Scheme (FTS)

Improving Quality in Physiological Services, IQIPS. Delivering quality physiological services. in Healthcare

THE MAIN DISCUSSED TOPICS:

Instructions for Application Submission Sylvia Lawry Physician Fellowship

RULES OF PROCEDURE FOR CALIBRATION LABORATORY ACCREDITATION

Tissue Viability Society. Strategy A future plan for the Tissue Viability Society (TVS) where we are going and how we will get there...

Social Media for the workplace & progression

Time Span Codes. Approved By 5/11/2016

Maintenance Review Board PR.MRB

Richard Haggas Blood Transfusion Quality Manager Leeds Teaching Hospitals NHS Trust

Transcription:

The CMC Process; Submission of CMCs By Ian Veldman AFRIMET AUV Chairman

Outline What are CMCs? CMC life cycle CMC preparation CMC submission, review & approval CMC maintenance

Calibration & Measurement Ca In the context of the CIPM MRA and ILAC Arrangement, and in relation to the CIPM-ILAC Common Statement, the following shared definition was agreed upon: A CMC is a calibration and measurement capability available to customers under normal conditions: (a) as published in the BIPM key comparison database (KCDB) of the CIPM MRA; or (b) as described in the laboratory s scope of accreditation granted by a signatory to the ILAC Arrangement. Where the term NMI is used it is intended to include Designated Institutes within the framework of the CIPM MRA.

Calibration & Measurement Ca For calibration and measurement certificates, the quantities, ranges of calibration and measurement capabilities are expressed as an uncertainty and listed in Appendix C of the MRA. The recognition of the calibration and measurement capabilities (CMCs) is done through peer review and inter regional approval. CMCs must be consistent with the results given in Appendix B, derived from the key comparisons. The CMCs listed in Appendix C are those that are ordinarily available to the customers of an institute through its calibration and measurement services. http://www.bipm.org/utils/common/cipm_mra/cipm_mra-d-04.pdf

CMC life cycle CMC preparation BIPM guide lines on CMC preparation; http://www.bipm.org/en/cipm-mra/documents/ CMC are submitted as per technical field service category; http://kcdb.bipm.org/appendixc/auv/auv_services.pdf Use the BIPM Excel template & instructions; http://www.bipm.org/en/cipm-mra/documents/cmc_excel_files.html RMO can already be involved in this process to assist.

CMC Excel Example Calibration or Measurement Service Measurand Level or Range Measurement Conditions/Independent Variable Expanded Uncertainty Reference Standard used in calibration List of Comparisons supporting this measurement/calibr ation service Quantity Instrument or Artifact Instrument Type or Method Minimu m value Maximu m value Units Parameter Specifications Valu e Units Coverag e Factor Level of Confiden ce Is the expanded uncertainty a relative one? Standard Source of traceabilit y Pressure sensitivity level Measurement IEC 61094- microphone 2:1992 type LS1P db (reference: 1 V/Pa) Frequency 63 Hz to 2 khz 0.04 db 2 95% No Reciprocity method NMISA CCAUV.A-K1, NPL 1990 ITRI-CMS 1990, 1991, 1995 Pressure sensitivity level Measurement IEC 61094- microphone 2:1992 type LS1P db (reference: 1 V/Pa) Frequency 2.5 khz to 3.15 khz 0.05 db 2 95% No Reciprocity method NMISA CCAUV.A-K1, NPL 1990 ITRI-CMS 1990, 1991, 1995 Pressure sensitivity level Measurement IEC 61094- microphone 2:1992 type LS1P db (reference: 1 V/Pa) Frequency 4 khz to 8 khz 0.06 db 2 95% No Reciprocity method NMISA CCAUV.A-K1, NPL 1990 ITRI-CMS 1990, 1991, 1995 Pressure sensitivity level Measurement IEC 61094- microphone 2:1992 type LS1P db (reference: 1 V/Pa) Frequency 10 khz 0.1 db 2 95% No Reciprocity method NMISA CCAUV.A-K1, NPL 1990 ITRI-CMS 1990, 1991, 1995

CMC Preparation Complete Excel spread sheet as per BIPM requirements Attach all supporting evidence Comparison results (Key/Supplementary) OR other supporting evidence; bilateral comparisons, pilot study results, publications, reports. Proof of CMC 3 rd party accreditation Or peer review through RMO, include peer review visit(s) and peer reviewer credentials. Submit through RMO with all supporting evidence, including quality system evidence.

CMC submission & review Intra-regional Intra-regional screening of CMC submissions from RMO member states. Is co-ordinated by the RMO relevant technical WG chair. This activity demand a lot of time and energy of the RMO relevant technical WG. Put in most of submission effort in here to ensure a speedy submission process.

CMC submission & review Intra-regional Technical WG review CMC submission for; Metrological soundness Compliance to BIPM Excel spread sheet requirements Proof of support by quality system/ 3 rd party accreditation Comparison support data Peer review information (where applicable) Comments and further information may be required from the WG chair and laboratory.

CMC submitted to BIPM for Inter-regional review by RMO relevant technical WG chair. Inter-regional evaluation of CMCs take place between RMOs: Submission is made electronically on restricted JCRB webb site. http://www.bipm.org/jcrbcmcs/ All RMO chairs are notified by e-mail. CMC submission & review Inter-regional All RMOs indicate if the will participate in the CMC review and by when. Report/Outcome of Inter-regional evaluation is communicated via JCRB webb site.

CMC submission & review

CMC submission & review Inter-regional Comments and requests for further information may be required from the RMOs via WG chair to the laboratory. Report/Outcome of Inter-regional evaluation is communicated via JCRB webb site. If all RMOs approve, then the CMCs are published on the KCDB by the BIPM.

CMC maintenance It is NMI responsibility to Internally review all CMC on a 4 to 5 year cycle. Need not be a specific exercise, it can be part of other quality procedures. Needs to be checked for: Metrological validity Technical support (supporting comparisons) Quality system support All non editorial changes need to go though full review process.

CMC maintenance Editorial changes can follow a fast track route. Essentially by-passing the inter-regional review. The NMI do not need to keep a copy of its CMC Excel spread sheet. This can be downloaded from the restricted access JCRB webb site and used for updates/changes. http://www.bipm.org/jcrbcmcs/publishedcmc.jsp?metarea=auv

END The CMC Process; Submission of CMCs

Summary of the role of the RMO The CMC review process CMC claim is prepared by laboratory Supporting evidence must be supplied Key or Supplementary comparison results Otherwise other supporting evidence, such as bilateral comparisons, pilot study results, publications, reports If third party accredited, submit through RMO If not, organise review through RMO. Includes peer review visit Submit through RMO with all supporting evidence, including peer review results

Summary of Intra Regional Review Intra Regional Review Submit to WG chair WG Chair organises review by technical experts in WG, may include experts from other RMOs WG chair collates comments and return to submitter Corrections are made, send back to RMO WG chair RMO WG chair do final check and send to the JCRB secretary, copied to the Regional Coordinator/JCRB representative

Summary of Inter Regional Review Inter Regional Review (CCQM) The files are published on the KCWG restricted site for review by other RMOs (inter regional review) Comments are send to the Regional coordinator and further information may be required from the WG chair and laboratory The files are updated and finally discussed at the Key Comparison WG of the CC Can require final corrections, then published on the restricted KCDB site for voting If all RMOs approve, published on the KCDB