STANDING OPERATING PROCEDURE (SOP) RANGE OPERATIONS HAND GRENADE RANGE IMSM-PLR 1 OCT 2016 TABLE OF CONTENTS

Similar documents
DOWN RANGE MOVEMENT INTO THE IMPACT AREA (BEYOND THE IMPACT BERM) IS PROHIBITED

RANGE 8A. Range 8A is an active; Light armor assault range located at Grid It is accessible from route 610.

RANGE 1. Primary Use: Individual small arms familiarization, qualification and short range (7-100 meters) shooting.

UNITED STATES MARINE CORPS MARINE CORPS AIR STATION POSTAL SERVICES CENTER BOX 8003 CHERRY POINT, NORTH CAROLINA

SOP RANGE 11 DESCRIPTION:

(b) All forms associated with this Order may be obtained from:

SMALL ARMS TACTICAL (SAT) RANGE RANGE DESCRIPTION

COMPETITION PISTOL RANGE RANGE DESCRIPTION

RANGE 10. Range 10 is an active; 81mm mortar firing position located at Grid It is accessible from OP 13 Road.

RANGE 12 RANGE DESCRIPTION. Range 12 is an active, small arms, live-fire range located at Grid It is accessible from MCB-1 and Rt 617.

REQUAL PISTOL RANGE DESCRIPTION

DEPARTMENT OF THE ARMY US ARMY ROTC CADET BATTALION UNIVERSITY OF PUERTO RICO-MAYAGUEZ PO BOX 9026 MAYAGUEZ, PUERTO RICO

LIVE FIRE CONVOY COURSE (LFCC)

GUN POSITION 44 RANGE DESCRIPTION

URBAN TRAINING CENTER (UTC) ZONE D

CHARLIE DEMOLITION RANGE. Charlie Demolition Range is an active Demolition Training Range located at Grid It is accessible from route MCB 2.

Range Safety Audio Script Module 3

CONVOY LIVE FIRE EXERCISE STANDARD OPERATING PROCEDURE

Marseilles Training Center 6 Sep Army Road Marseilles, IL PORTABLE LIVE FIRE SHOOT ROOM STANDARD OPERATING PROCEDURE

(1) Inspect Ammunition Supply Points (ASP) at least semi-annually.

Summary Report for Individual Task Supervise a CBRN Reconnaissance Status: Approved

GOETTGE DEMOLITION RANGE

TRAIN-THE-TRAINER PROGRAM

Example of an Instructor s Battle Drill Exercise Lesson Guide

DMAIL Regulation Sparta. Training. Area UNCLASSIFIED

Summary Report for Individual Task M-3335 Supervise Driver's Training Program Status: Approved

UTAH TRAINING CENTER RANGE SOP

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

EXAMPLE SQUAD OPERATION ORDER FORMAT. [Plans and orders normally contain a code name and are numbered consecutively within a calendar year.

Range Operating Instructions

STANDARD OPERATING PROCEDURE

RECRUIT SUSTAINMENT PROGRAM SOLDIER TRAINING READINESS MODULES Conduct Squad Attack 17 June 2011

* Appendix A Sample Tactical SOP for the Support Battalion and Support Squadron Command Post

Range Safety Audio Script Module 2

UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA

Army National Guard Range Safety Program, Policy, and Standards

RISK MANAGEMENT WORKSHEET

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

I. Situation. A. Enemy forces. (WHO) is (Activity) in grid their estimated size is with weapon capability. Their Morale is and their intent is to

32 Military Police Cadets RANGE SAFETY ORDERS

Impact Area: Zulu Impact Area. General Instructions

Depict the following operational terms and graphics. CO boundaries, Air and ground axis of advance for shaping and decisive Ops, unit symbols,

FORT KNOX REGULATION IS CURRENTLY UNDER REVISION. SOME OF ITS CONTENT IS OUTDATED.

Summary Report for Individual Task Plan Fixed-Site Decontamination Status: Approved

17895 Infantry Squad Battle Course (ISBC) RANGE DESIGN GUIDE

Summary Report for Individual Task H-3527 Determine Compatibility of Dangerous or Hazardous Cargo Status: Approved

Summary Report for Individual Task H-3511 Direct Lashing Containers on the Deck of a Landing Craft Status: Approved

Commanding Officer, Marine Corps Air Station, Cherry Point Distribution List

CITY OF MADISON POLICE DEPARTMENT STANDARD OPERATING PROCEDURE. Police Weaponry

Platoon. 10 o clock. 1 S d. 3rd Squad. PL moves forward with Recon Element (2) Recon Element clears ORP (3) o clock

Certification Course

Summary Report for Individual Task A-0048 Borescope the 120 MM Main Gun on the M1A1/M1A2 Series Track Vehicle Status: Approved

Special Instructions Continued on Next page

CHAPTER 8. Range Training Facilities. Section I. LIVE-FIRE RANGES

Government of Azerbaijan

Environment: Some iterations of this task should be performed in MOPP 4. This task should be trained under IED Threat conditions.

TACTICAL ROAD MARCHES AND ASSEMBLY AREAS

EXECUTIVE MEMBERSHIP APPLICATION AND AGREEMENT

Niagara County Emergency Services

GREY NUNS COMMUNITY HOSPITAL ACTIVE ASSAILANT EMERGENCY RESPONSE PLAN

Staff Coordination and Control of CA Operations

UNCLASSIFIED. Range and Training Facilities. NE ARNG Regulation Safety

Eighth United States Army Korea Regulation United States Army Installation Management Agency Korea Region Office. 10 October 2006.

17897 Infantry Platoon Battle Course (IPBC) RANGE DESIGN GUIDE

150-MC-0006 Validate the Protection Warfighting Function Staff (Battalion through Corps) Status: Approved

Respond to an Active Shooter

Standards in Weapons Training

Summary Report for Individual Task 805P-COM-1108 Perform the Ability Group Run (AGR) Status: Approved

Patrols and Patrolling

Summary Report for Individual Task 805B-79R-3402 Conduct a Future Soldier Orientation (FSL) Status: Approved

Driver Training Assessment Checklist

1. Officers carrying weapons on or off duty must meet the below listed requirements. 1) Be commissioned as a State Constable

Virginia Commonwealth University Police Department

Training and Evaluation Outline Report

Sample Tactical SOP for the DISCOM Command Post

Summary Report for Individual Task H-4501 Monitor External Sling Load Operation Status: Approved

Summary Report for Individual Task H-3501 Manage Helicopter External Sling Load Operations Status: Approved

LAKEWOOD FIRE DEPARTMENT STANDARD OPERATING GUIDELINES

CAMP RUDDER JROTC CADET LEADERSHIP CHALLENGE SAFETY SOP

Summary Report for Individual Task 805C-42A-4023 Review the Awards and Decorations Program Status: Approved

805C-COM-6004 Supervise Unit Postal Services Status: Approved

PART TWO INTERIOR GUARD CHAPTER 4 ORDERS

FLW Regulation 16 June 2003 No Installations RANGES AND TRAINING AREAS

DRILLS FOR THE SMOKE/DECONTAMINATION PLATOON

Perform remedial action for a squad automatic weapon (B)

Summary Report for Individual Task H-2306 Conduct Rail Loading Operations Status: Approved

Emergency Operations Plan

Training and Evaluation Outline Report

Training and Evaluation Outline Report

Summary Report for Individual Task H-1532 Operate 5K Light Capacity Rough Terrain Forklift (LCRTF) Without a Load Status: Approved

RECRUIT SUSTAINMENT PROGRAM SOLDIER TRAINING READINESS MODULES React to Contact 17 June 2011

RANGE AND TRAINING REGULATIONS R217 must be schedule In Order To Use Mortar Option

Mobilizing Safety Guide

Summary Report for Individual Task M-2408 Implement Defensive Procedures When Under Attack/Ambush in a Truck Convoy Status: Approved

Chapter 7 Battle Drills

ACTIVE SHOOTER GUIDEBOOK

Boy Scouts of America Indianhead Council

PATROL RIFLE PROGRAM

PRACTICE SELF-AUDIT TOOL FOR EXTERNAL FULL PORFOLIO (EFP) APPLICANTS

SAN DIEGO POLICE DEPARTMENT PROCEDURES

Transcription:

STANDING OPERATING PROCEDURE (SOP) RANGE OPERATIONS HAND GRENADE RANGE IMSM-PLR 1 OCT 2016 TABLE OF CONTENTS 1. References. 2 2. Purpose.. 2 3. Organization.. 2 4. Scope. 2 5. Certification.. 2 6. Descriptions.. 2 7. Direction of Fire 3 8. Right and Left Limits 3 9. Maximum Elevation. 3 10. Targets.. 3 11. Medical Requirements.. 3 12. Equipment Requirements.. 3 13. Personnel Requirements... 3 14. Personnel Responsibilities 4 15. Communications... 4 16. Safety 4 17. Conduct of Training.. 5 18. Clearing Procedures.. 5 19. Restricted Areas 5 Appendix A Duties of the Officer in Charge. 6 Appendix B Duties of the Range Safety Officer... 8 Appendix C Medical Evacuation Support. 10 Appendix D Troop Briefing.. 12 1

1. References a. AR 385-63, 30 January 2012, Range Safety b. DA PAM 385-63, 16 April 2014, Range Safety c. TC 25-8, 22 July 2016, Training Ranges d. TC 3-23.30, 22 Nov 2013, Grenades and Pyrotechnic Signals e. ASA Regulation 350-1, 1 October 2016 2. Purpose: To establish guidelines and procedures for the operation of the Hand Grenade Range. 3. Organization: Camp Bullis Range Operations falls under the operational control of Army Support Activity (ASA) Joint Base San Antonio (JBSA). The Range Officer is responsible for overall Range Operations and safety. Range Operations consists of Operations, Safety, Range Maintenance, Integrated Training Area Maintenance (ITAM) and Supply. 4. Scope: This SOP applies to all Active, Reserve, National Guard and other agencies that utilize Camp Bullis Range Complex. 5. Certification: Battalion Commanders (or above) will appoint and certify, in writing, that the Officer-in-Charge (OIC) and Range Safety Officer (RSO) are competent in the weapons systems being used. 6. Descriptions a. Hand Grenade Familiarization (1) Primary use: This range is used for familiarization of the employment of live hand grenades. (2) Ammunition authorized: M67 Hand Grenade and M18A1 Claymore Mines (3) Range has five (5) throwing bays, a ready bunker, and an ammunition breakdown area. b. Hand Grenade Qualification Course (1) Primary use: This is used for training for tactical employment of hand grenades and qualification. (2) Ammunition authorized: Training Practice Grenades with or without M228 Fuse 2

(3) Range has seven (7) qualification stations. 7. Direction of Fire: All target holders are fixed and not to be removed or adjusted from their locations on fixed positions. 8. Left and Right Limit: Left and right designated limit markers are indicated by Red and White markings during daylight hours and a red beam of light during hours of limited visibility. 9. Maximum Elevation: Loaded weapons will be pointed down range at the designated Berm/Impact area in such a manner as to ensure that rounds are trapped by the Berm/Impact area (below the designated fixed target position for each firing position). 10. Targets: fixed Stationary E Type Silhouettes and Qualification Stations. 11. Medical Requirements: Follow guidance in accordance with (IAW) ASA Regulation 350-1 12. Equipment Requirements: Item Description ASA Regulation 350-1 Hand Grenade Range SOP Range Flag and/or Beam Light (night operations) Hearing Protection Brooms Brass Deflectors for M16A1 Rifles Emergency Signaling Devices Radio Communications and Fire Extinguishers Dedicated Evacuation Vehicle Additional Equipment IAW unit's TACSOP Issuing Facility Range Operations Range Operations Range Operations 13. Personnel Requirements a. Officer-in-Charge (OIC) must be an E-6 or above and certified in writing by the Battalion Commander in live fire training for weapon(s) used. The OIC must have attended the Range Safety briefing. b. The RSO must be E-5 or above and certified by the Battalion Commander to be proficient in live fire training for weapon(s) used and must be weapons qualified. The RSO will not have other duties assigned. The RSO must have attended the Range Safety briefing. c. Line Safeties as required by Range Operations (on average one Line Safety is required for every four firers). d. Ammunition Supply Point (ASP) personnel as appropriate. 3

e. Required medical support must be a Combat Life Saver (CLS) or higher. An evacuation vehicle with an aid bag and litter is required. 14. Personnel Responsibilities: The responsibilities of the OIC and RSO can be found in Appendix A and B respectively. 15. Communications a. Primary means of communications with Range Operation is Frequency 34-20. Hand held radios will be issued by Range Operations when available. b. Secondary means of communications with Range Operation is via telephone located in the Range Towers. Range Operations Fire Desk telephone number is (210) 295-7510. c. The Range Tower is set-up with an electrical Public Announcement (PA) system to facilitate troop movement on the range. d. Units must make hourly contact with Range Operations during training. 16. Safety a. The OIC or RSO must give a troop briefing prior to conducting any training. The briefing will include, at a minimum, the items listed in Appendix D. b. Users are required to utilize a signal clearly heard and understood by all to "Cease Fire/Training". c. No targets or frames will be moved from designated target areas. Deviation from standard target type and location requires approval from Range Operations. d. Muzzle awareness must be emphasized. e. Before any weapons leave the firing line, they must be cleared. f. If an electrical storm occurs, the RSO will have all weapons locked and cleared and all personnel directed to a safe area. g. All personnel will be inspected for brass and ammo prior to leaving the range. NOTE Only the OIC, RSO, firers, coaches, and safeties are authorized on the firing line when live fire is in progress. All other personnel must remain in the administrative area(s) designated by the OIC until the live fire exercise has been completed and weapons have been cleared. 4

17. Conduct of Training a. No alterations to the firing range configuration are authorized unless coordinated with the Range Officer. b. All vehicles will use designated roads and parking areas. Vehicles are not permitted on the grass. c. Risk management must be integrated into the exercise plans and be part of the unit Operations Order (OPORD) for all live fire exercise. 18. Clearing Procedures: Units utilizing the firing range have the inherent responsibility for ensuring the facilities are policed and returned to their original sterile condition upon completion of training. Leaders will ensure that the range complex and any used areas have been inspected and cleared by Range Operations staff before leaving the premises. 19. Restricted Areas: All range and impact areas are restricted. 5

APPENDIX A DUTIES OF THE RANGE OFFICER IN CHARGE (OIC) 1. Prior to training/firing the OIC will ensure that: a. He/she is appointed and certified in writing by the Battalion Commander to perform the duties as OIC in a live fire training. b. The firing range is scheduled for unit use. c. An authorized RSO has been designated. d. Both OIC and RSO have received a Range Safety Briefing from Range Operations. e. Both OIC and RSO have read and understand the range SOP. f. A Deliberate Risk Assessment Worksheet has been completed and approved by the appropriate residual risk authority. g. The correct training facility occupied. h. A red range flag is flown from the flag pole. For night training/firing, a beam light will be used in place of a flag. i. Communications have been established with Range Operations. Land line number to Range Operations is (210) 295-7510. j. All personnel are given a Safety Briefing by the ROIC or RSO. k. All equipment required by this SOP and/or other regulations are present on the site. l. All personnel have received a safe handling of ammunition and weapons briefing. m. Road guards, barriers, and/or signs have been posted, if required. n. An approved surface danger zone (SDZ) overlay is on hand, if applicable. o. All personnel are aware of the following: (1) The identity and location of OIC, RSO, Radio/Telephone Operator (RTO), medic, evacuation vehicle, ammo guards, and others as required. (2) The requirement to wear authorized hearing protection. (3) The firing limits of the facility being used. 6

p. Clearance to conduct training/firing has been granted by Range Operations. When requesting clearance to train/fire, the OIC/RSO will provide the information as required by Range Operations. The OIC/RSO must ensure that the Range Operations initials are recorded for authorization to commence training/firing. q. Range Operations is provided with unit's call sign and receive a "hot time". r. The evacuation vehicle driver knows the route to Medical Care Facility. 2. During use of the firing range, the OIC/RSO will ensure that: a. Weapons effects are observed to ensure projectiles land within the prescribed limits. b. Weapons are cleared and checked during temporary suspensions of firing. c. Records are maintained on the type (DODIC) of ammunition fired and number of rounds fired. d. A cease fire/training is ordered when: (1) Directed by Range Operations. (2) A safety violation, accident or incident occurs. If necessary, MEDEVAC will be requested. Range Operations must be notified. (3) A fire is started. Range Operations will be notified and the unit will fight the fire as long as troops are not endangered. e. While the range is in a hot status, both the OIC and RSO must be present on the site. 3. After use of the firing range, the OIC will ensure that: a. All weapons are cleared of ammunition and all ammunition and brass are removed from personnel before departing the range. b. Ammunition and brass are not abandoned, buried, or otherwise disposed of in an unauthorized manner. c. All expended brass and residue is collected for turn-in to the ASP. d. Range is policed and returned to its original condition. e. Coordination for inspection and final clearance from Range Operation is completed. 7

APPENDIX B DUTIES OF THE RANGE SAFETY OFFICER (RSO) 1. The RSO is responsible to the OIC for the safe operation of the range. Prior to training/firing the RSO will ensure that: a. He/she is appointed and certified in writing by the Battalion Commander to perform the duties as the RSO in live fire training for weapons used. b. The RSO will have no other duties. c. He/she has received a Range Safety Briefing from Range Operations. d. He/she is thoroughly familiar with the applicable portions of DA PAM 385-63, ASA Regulation 350-1. e. Additional safeties/controllers have been briefed on the conduct of training and are familiar with the specific requirements of this SOP. f. A red range flag is flown from the flag pole. g. Authorization has been granted by Range Operations for night firing. A blinking red light will be used in place of a flag. h. Communications have been established with Range Operations (CBOP 2). Land line number to Range Operations is (210) 295-7510. i. All equipment required by this directive and/or other regulations are present on the range. j. All personnel receive a safety briefing to include a safe handling of ammunition and weapons. k. Road guards, barriers, and/or signs have been posted, if required. l. An approved surface danger zone (SDZ) overlay is on hand, if applicable. m. All personnel are aware of the following: (1) The identity and location of the OIC, RSO, controllers, RTO, medic, evacuation vehicle driver, ammo guards, and others as required. (2) The requirement to wear authorized hearing protection. (3) The firing limits of the facility being used. n. Clearance to train/fire has been granted by Range Operations. 8

o. Range Operations initials and "hot time" is noted as record of clearance to commence training/firing. p. The evacuation vehicle driver knows the route to Medical Care Facility. 2. During use of Ranges, the RSO will ensure that: a. Weapon effects are observed to ensure projectiles land within the prescribed limits. b. Weapons are cleared and checked during temporary suspensions of firing. c. A cease fire/training is ordered when: (1) Directed by Range Operations. (2) A safety violation, accident or incident occurs. If necessary, MEDEVAC will be requested. Range Operations must be notified. (3) A fire is started. Range Operations will be notified and the unit will fight the fire as long as troops are not endangered. d. While the site is in a hot status, both the RSO and OIC must be present on the site. 3. After use of the firing range, the RSO will ensure that: a. All weapons are cleared of ammunition and all ammunition and brass are removed from personnel before departing the site. b. Ammunition and brass are not abandoned, buried, or otherwise disposed of in an unauthorized manner. c. All expended brass and residue is collected for turn-in to the ASP. 9

APPENDIX C MEDICAL EVACUATION SUPPORT TO FIRING RANGES SOP 1. REQUEST FOR MEDEVAC SUPPORT. In the event of serious injury or illness where time may be a factor in saving life, limb, sight, or to prevent undue suffering, aero medical evacuation will be used. The following procedures will be followed: a. Upon determination of MEDEVAC requirements by the Medic on site, immediately contact Range Operations. b. Provide the following information to Range Operations in this format: LINE ONE LINE TWO LINE THREE Location of Pickup Site Call Sign Number of patients by precedence: #1 URGENT: Emergency cases which must be evacuated immediate to save life or limb. #2 PRIORITY: Patients requiring prompt medical care not locally available. This precedence will be used when it is anticipated that the patient must be evacuated within four hours or his/her medical condition will deteriorate to the degree that he/she will become an URGENT case. #3 ROUTINE: Patients requiring evacuation but whose condition is not expected to deteriorate significantly during the first several hours or longer. LINE FOUR LINE FIVE LINE SIX LINE SEVEN LINE EIGHT LINE NINE LINE TEN Special Equipment required: None, hoist, semi-rigid litter, forest/jungle penetrator Number of patients by type of wound, injury or illness: Litter, ambulatory (sitting) Security of Pickup Site (N/A while in training) Method of marking Pickup Site: Panels, pyrotechnic/smoke signal, signal person, strips of fabric, tree branches, pieces of wood or stones placed together, signal lamp/flashlight, vehicle lights, open flame Patient Nationality and Status: US Military, US Civilian, Non-US Military, Non-US Civilian NBC Contamination (N/A while in training) Terrain Description NOTE At no time will the name or social security number of injured personnel be transmitted over the radio. 10

c. After initial call to Range Operations, switch to frequency 34.20 ONLY WHEN INSTRUCTED TO DO SO BY RANGE OPERATIONS. d. Stay on radio throughout medevac situation. e. Be prepared to provide SMOKE for DAYLIGHT or LIGHTS for NIGHT at MEDEVAC s request. MEDEVAC will not land to white smoke. 2. After Range Operations has been notified of MEDEVAC departure, Range Operations will resume normal operations unless unusual circumstances exist. 11

APPENDIX D TROOP BRIEFING M A N D A T O R Y TROOP BRIEFING: The OIC or RSO will brief all soldiers on the following items prior to requesting occupation time from Range Operations. This is a general list and does not preclude the unit from emphasizing other areas of concern. Identification of OIC and RSO and their responsibilities. Location of range cadre, including range OIC, RSO, Safety/Controller personnel, RTO, medic, evacuation vehicle and driver, ammo personnel, and others as required. Prescribed uniform while at Firing Range. No pushing, shoving or horseplay at anytime while on the site. Ammunition holding area/issue point procedures. Procedures taken in the event of a fire. Medical emergency procedures. Vehicles larger than 2 1/2 ton and all tracked vehicles operating administratively within the range require ground guides front and rear. Anyone observing an unsafe situation will call CEASE FIRE/TRAINING. The exercise will not be resumed until the OIC or RSO has investigated the situation and declared it safe to resume training. Animals that have wandered on the site are to be left alone. Personal hygiene and use of facilities. Designated chow and break area. Soldiers must maintain "muzzle awareness" at all times. Firers must not engage targets that have not been designated as targets. In case of malfunction - The firer having the malfunction will attempt to correct the malfunction by applying immediate action. 12

- If the malfunction cannot be corrected by immediate action, cease fire, clear the weapon, and notify your Range Safety. The firer will maintain positive control of any weapon system while handling or employing it. - Firers will not hand a weapon to another person until it has been properly unloaded/cleared and the bolt or slide locked to the rear, unless instructed to do otherwise by Range Safety. - All weapons will be oriented downrange during loading, unloading, and clearing procedures. The use of hearing protection is mandatory The following extract is from FM 23-9: - The RSO points out the left and right limits of the range. Firers never fire or point their weapons outside the limits of these poles. - When not on the firing line, the selector lever is on SAFE and the bolt locked to the rear. - Consider the weapon loaded at all times, even in the break areas. Never point the weapon at anyone. - Firers will always enter and exit the firing line at the base of the tower. - Before occupying the firing positions, inspect the positions for harmful animals and insects. - Firers will always point the muzzle of the weapon downrange whenever on the firing line. The firing finger is not placed within the trigger housing area. - When on the firing, the selector lever is on SAFE, the bolt locked to the rear, and the dust is open. - Never touch your weapon while personnel are downrange or in front of the firing line. - Load the magazine into the weapon only on the command from the tower. - Before leaving the firing line, a Safety NCO must clear the weapon. - Once cleared off the firing line, firers report immediately to the ammunition point and turn in all ammunition and expended brass. - No one will leave the range until he/she has been inspected for ammunition and brass. 13