Exelkn. PSLTR: # U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Similar documents
Request for Relief No. 20, Revision 0, for Units I and 2 3rd Ten Year Inservice Inspection Interval

CProgress Energy. Qk4~ May 21, F U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC

TRAINING ON BACKGROUND AND IMPLEMENTATION OF ASME OM CODE, APPENDIX III

ASME Nuclear Conformity Assessment. Bernard E. Hrubala Sr. Vice President Code and Standards October 7, 2008

Preservice Inspection (PSI) of Nuclear Power Plant Components

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C July 7, 2011

2. Classification of Nuclear Items Ability to identify nuclear components, parts, and appurtenances.

NRC INSPECTION MANUAL STSB

Qualifications for Authorized Inspection

Regulatory Approach for License Renewal for Commercial Nuclear Power Reactors in the USA

GUIDE FOR ASME REVIEW TEAMS FOR REVIEW OF APPLICANTS FOR ASME CERTIFICATES OF AUTHORIZATION (V, HV, UD, UV, UV3, UD3, TD, TV)

Outage dates (duration): September 5, 1996 to May 27, 1999 (2.7 years) Reactor age when outage began: 8.8 years

Nuclear Operating Company

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C

FENOC AOLVS. February 3, 2000 PY-CEI/NRR-2463L. United States Nuclear Regulatory Commission Document Control Desk Washington, D. C.

NUREG-0800 U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN ADMINISTRATIVE PROCEDURES - GENERAL REVIEW RESPONSIBILITIES

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF REACTOR REGULATION WASHINGTON, DC September 26, 2005

July 29, 2009 WATTS BAR NUCLEAR PLANT NRC PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION REPORT /

February 13, 2013 EA

Control Number: Item Number: 209. Addendum StartPage: 0

May 23, Docket No License No. DPR-12

license AUTHORITY FILE CC Apv il., 1982

GUIDE FOR ASME REVIEW TEAMS FOR REVIEW OF APPLICANTS FOR ASME CERTIFICATES OF AUTHORIZATION {A, M, PP, S, E, H, HLW, U, UM, U2, U3, PRT and T}

U.S. Nuclear Regulatory Commission

PHMSA Update. Kenneth Y. Lee API AGA Joint Committee Oil & Gas Pipeline Welding Practices. Engineering & Research Division

Fluorine Gas Mist Pot Fails

HUMBOLDT BAY INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE APPLICATION ENVIRONMENTAL REPORT SAFETY ANALYSIS REPORT

Exelton RS August 1, U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC

GUIDE FOR COMPLETING NATIONAL BOARD FORM NR-1, REPORT

Radiation Protection Program Updates

February 8, 2017 SUBJECT: GRAND GULF NUCLEAR STATION - NRC INTEGRATED INSPECTION REPORT /

NEI [Revision 0] Guidelines for a Certified Fuel Handler Training and Retraining Program

1. General. 2. Background

AnJEDISON 10 CFR CFR March 31, ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C.

DRAFT REGULATORY GUIDE

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.8 (Drafts were issued as DG-1084 and DG-1012)

In the Matter of )Docket No Tennessee Valley Authority ) BROWNS FERRY NUCLEAR PLANT (BFN) - STATUS OF UNIT 1 RESTART ISSUES, REVISION 3

NRC UPDATE EP REGULATORY ACTIVITIES. Glenn M. Tracy / Kathy Halvey Gibson Office of Nuclear Reactor Regulation

Coast Guard NVIC Oct 1992

U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN

U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN

Attachment J-8 Contractor / Supplier Submittal Register

ILLINOIS VALLEY COMMUNITY COLLEGE, DISTRICT #513 Bid # PR Purchasing Department 815 North Orlando Smith Road Oglesby, Illinois 61348

Religious Ministry Support REFERENCE / AUTHORITYSOURCE DOCUMENT Information Sheet

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD

NAVSEA STANDARD ITEMS FY-19 CH-2 (26 MAR 2018)

Export-Controlled Technology at Contractor, University, and Federally Funded Research and Development Center Facilities (D )

REQUEST FOR PROPOSAL INDEPENDENT CONSULTANT EXPERT OYSTER CREEK SAFETY ADVISORY PANEL

Final Agenda. Motor-Operated Valve Users' Group Annual Meeting

PAULY ELEMENTARY SCHOOL RELOCATABLES P1-P5 & R23-R26

Subj: CORROSION PREVENTION AND CONTROL (CPAC) PROGRAM

NUCLEAR REGULATORY COMMISSION. [Docket Nos ; NRC ] Northern States Power Company - Minnesota; Prairie Island Nuclear Generating Plant

REGISTRATION FOR MAY 2013 CODE WEEK ATTENDEES

Gasket Failure Causes Leak

QUALIFICATION REVIEW REPORT FOR ACCREDITATION OF AUTHORIZED INSPECTION AGENCIES (INSERVICE)

NRC Public Meeting October 27, 2014

Research and Test Reactor Licensing Actions and Lessons Learned

REQUEST FOR PROPOSAL MARKETING PLAN FOR ILLINOIS VALLEY COMMUNITY COLLEGE PROPOSAL #RFP2015-P05

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C April 10, 2018

SUMMARY REPORT. OPERATIONS and MAINTENANCE PLANS and CRITERIA. HOUSATONIC RIVER and NAUGATUCK RIVER FLOOD PROTECTION PROJECTS SECTION 1

REQUEST FOR PROPOSALDevelopment of a Local

COMMONWEALTH OF KENTUCKY BEFORE THE PUBLIC SERVICE COMMISSION

ILLINOISVALLEY COMMUNITY COLLEGE

Telecommunications Advisors Since March 4, 2015 VIA ECFS

Multi-Purpose Paper Bid No. PR10-B14

AGENDA 3. GRP ITEMS FOR CONSIDERATION BY THE SJRA BOARD ON OCTOBER 31, 2013:

Request for Qualifications and Proposals (RFQ/P) #564. for. Program and Construction Management Services

November 18, Dear Ms. Vietti Cook:

Okeechobee Utility Authority Engineering Services for Water Treatment Plant Improvements

Oklahoma State University Policy and Procedures INSTITUTIONAL RADIATION SAFETY POLICY

Human Subject Regulations Decision Charts

APPENDIX A ENFORCEMENT GUIDANCE MEMORANDA

Life Extension of Nuclear Power Plants

NUCLEAR REGULATORY COMMISSION [NRC ] Preparation of Environmental Reports for Nuclear Power Stations

NRC INSPECTION MANUAL IRIB

REQUEST FOR BID SCHICK 33 SIZE 1 AND SIZE 2 DIGITAL SENSORS FOR ILLINOIS VALLEY COMMUNITY COLLEGE BID # BID2017-B01

ADDENDUM NUMBER 1. September 15, 2017

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE COMMISSION

SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is discontinuing a rulemaking

DRAFT REGULATORY GUIDE

NAVSEA STANDARD ITEM CFR Part 61, National Emission Standards for Hazardous Air Pollutants

REQUEST FOR INFORMATION Generating Alternative Energy from Philadelphia Waterways CITY OF PHILADELPHIA. Issued by: THE Philadelphia Energy Authority

REQUEST FOR PROPOSALS ACCOUNTING AND AUDITING SERVICES

NAVSEA STANDARD ITEM CFR Part 61, National Emission Standards for Hazardous Air Pollutants

1. Perform maintenance tasks associated with L120 and SMB actuators: 3. Evaluate L120 and SMB actuators for correct operation.

Final Rule Material: Overview

First Annual RCRA CCR Unit Inspection Report January 2016 WASTE DISPOSAL AREA SURFACE IMPOUNDMENT

SEALED PROPOSAL REQUEST FOR PROPOSAL. Professional Archaelogical Services

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT WATER DIVISION - WATER SUPPLY PROGRAM ADMINISTRATIVE CODE

Subj: CHANGE OR EXCHANGE OF COMMAND OF NUCLEAR POWERED SHIPS. Encl: (1) Engineering Department Change of Command Inspection List

X STANDARD REVIEW PLAN

NB-263, RCI-1, RULES FOR COMMISSIONED INSPECTORS (RCI-1)

City of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR

BASIN CITY WATER AND SEWER DISTRICT Request for Qualifications

Functions important to nuclear power plant safety, and training and qualification of personnel

Chapter 11. Cultural Districts

REQUEST FOR PROPOSAL INFORMATION SECURITY CONSULTANT FOR ILLINOIS VALLEY COMMUNITY COLLEGE PROPOSAL #RFP2013-P03

BELTON INDEPENDENT SCHOOL DISTRICT

DEPARTMENT OF DEFENSE STANDARD PRACTICE

Emergency Preparedness Final Rule Implementation

Transcription:

Exelkn. Exelon Generation Company, LLC www.exeloncorp.com Nuclear Dresden Nuclear Power Station 6500 North Dresden Road Morris, IL 60450-9765 February 2, 2001 1OCFR50.12 PSLTR: #01-0018 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Dresden Nuclear Power Station, Unit 2 Facility Operating License No. DPR-19 NRC Docket No. 50-237 Subject: Reference: Supplemental Information for Request for Schedular Exemption 10 CFR 50.55a(g)(6)(ii)(B) Expedited Examination of Containment Letter from Preston Swafford (Exelon) to U.S. NRC, "Request for Schedular Exemption 10 CFR 50.55a(g)(6)(ii)(B) Expedited Examination of Containment," dated December 8, 2000 In the referenced letter, Exelon Nuclear requested a schedular exemption for Dresden Nuclear Power Station (DNPS), Unit 2, from implementation of inservice examinations of the containment by September 9, 2001, as required by 10 CFR 50.55a(g)(6)(ii)(B), "Expedited examination of containment." This schedular exemption was requested to extend the implementation date by 90 days to allow completion of first period examinations during the next Unit 2 refueling outage, currently scheduled to begin in October 2001. A teleconference with the NRC was held on December 20, 2000, to discuss our submittal. The NRC requested additional information in order to complete its review. Our response is included as an attachment to this letter. Should you have any questions concerning this letter, please contact Mr. D. F. Ambler at (815) 942-2920, extension 3800. Respectfully, Preston Swafford Site Vice President Dresden Nuclear Power Station Attachment: Request for Schedular Exemption Questions cc: Regional Administrator - NRC Region III NRC Senior Resident Inspector- Dresden Nuclear Power Station Office of Nuclear Facility Safety - Illinois Department Nuclear Station

References: (1) Letter from R.M. Krich (ComEd) to U.S. NRC, "Request for Inservice Inspection Program Relief Regarding Containment Inspections by Approved Alternate Means," dated May 8, 2000 (2) Letter from A.J. Mendiola (U.S. NRC) to O.D. Kingsley (ComEd), "Byron, Dresden and LaSalle - Evaluation of Relief Requests: Use of 1998 Edition of Subsections IWE and IWL of the ASME Code for Containment Inspection," dated September 18, 2000 Question: Why did Dresden Nuclear Power Station (DNPS) wait to request the use of the ASME B&PV Code Xl, Subsection IWE 1998 Edition until after the last available refueling outage (D2R16)? Response: Due to a lack of planning and oversight prior to the last refueling outage (D2R16) and without any relief requests submitted, a work scope was developed that would meet the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code Xl, "Rules for Inservice Inspection of Nuclear Plant Components," Subsection IWE, "Requirements for Class MC and Metallic Liners of Class CC Components of Light-Water Cooled Plants," 1992 Edition with 1992 Addenda, except for those requirements where relief was to be requested. It was believed at the time that these actions, with approval of a relief request submitted after the refueling outage, would satisfy the Period 1 inspection requirements. However, due to a lack of understanding of the ASME Code requirements and incomplete ISI program documents, a number of the examinations performed during D2R16 did not meet the requirements of the ASME B&PV Code Xl, Subsection IWE 1992 Edition with 1992 Addenda. In addition, it was subsequently determined that those examinations in compliance with the ASME B&PV Code Xl, Subsection IWE 1992 Edition with 1992 Addenda did not meet the requirements of the planned relief request, which utilizes the 1998 Edition of ASME B&PV Code Xl, Subsection IWE. Therefore, after the refueling outage, it was determined that all Period 1 examinations needed to be re-done, in accordance with the 1998 Edition. Exelon then decided to make a three station submittal, noted in Reference (1), requesting approval to use ASME B&PV Code Xl, Subsection IWE, 1998 Edition in lieu of the 1992 Edition with 1992 Addenda. In that submittal the need for a schedular exemption was identified and it was noted that it would be submitted separately. Given the multi-station submittal, it was decided by DNPS that the schedular submittal should wait until use of the 1998 Edition was approved.

DNPS has since taken actions to correct the deficiencies in the Containment ISI program. Period 1 inspections were successfully completed for Unit 3 during the last refueling outage, completed on October 3, 2000. The Unit 2 portion of the program is being developed to support completion of Period 1 examinations on Unit 2 by the end of the upcoming refueling outage. These actions will result in performance of all Period 1 examinations for Unit 2 and 3 in accordance with Relief Request MCR-02 (1998 Edition). Question: What ASME Subsection IWE components were inspected during the last refueling outage (D2R16)? Response: The following Table summarizes the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code Xl, "Rules for Inservice Inspection of Nuclear Plant Components," Subsection IWE, "Requirements for Class MC and Metallic Liners of Class CC Components of Light-Water Cooled Plants" components that were inspected during the first inspection period.

ASME Section XI, Subsection IWE, First Period Inspection Requirements Applicable to Dresden Nuclear Power Station Unit 2 Category Item Description Components Inspected Conditions Found Compliance with 92 Edition E-A E.1 1 General Visual examination General Visual examination Examination revealed no with 92 Addenda General Visual examination E-D of accessible surface areas. was performed during degradation of accessible was in compliance with 92 D2R16. containment surfaces. Edition with 92 Addenda. E5.1 0 VT-3 of Seals Gaskets associated with the Two shear lugs failed their Examination requirements E5.20 VT-3 of Gaskets following disassembled LLRTs. Connections were for Item Numbers E5.10 connections were inspected disassembled and gaskets and E5.20 were not met. (VT-3): were visually examined. Intended to request relief * Two suppression The gaskets were found from the requirements of chamber access hatches. degraded from age and these item numbers. A relief * Two shear lug hatches were replaced. request was prepared to * Two equalizing valves Remaining gaskets were credit App. J in lieu of the acceptable. VT-3 of seals and gaskets. This relief request was canceled in lieu of Relief Request MCR-02 (Reference 1), which exempts gaskets and seals. E5.30 VT-3 of Moisture Barriers 25% (1 of 4) of the moisture Inspection of the drywell to VT-3 examinations were in barriers were inspected. basemat moisture barrier compliance with 92 Edition revealed degradation due with 92 Addenda. to age. Based on visual inspection of the liner adjacent to the moisture barrier, the degradation was not significant enough to permit corrosion of the liner. Replacement of the moisture barrier is scheduled during D2R17.

ASME Section XI, Subsection IWE, First Period Inspection Requirements Applicable to Dresden Nuclear Power Station Unit 2 Category Item Description Components Inspected. Conditions Found Compliance E-G E8.10 VT-1 of Bolted Connections Bolting associated with the No recordable degradation Examination Requirements (All disassembled following disassembled of the bolted connections were not met since all connections must be connections were inspected was observed, disassembled connections inspected) (VT-1): were not inspected during * Two suppression D2R16. chamber access hatches * Two shear lug hatches * Two equalizing valves * Five additional shear lug hatches were inspected in place