Hill-Rom Advanta 2 Bed Tips Simply Intuitive FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE ADVANTA 2 BED, SEE USER S MANUAL.

Similar documents
Simply Intuitive. The Hill-Rom Advanta 2 Bed

Simply Practical. The Hill-Rom CareAssist ES Hospital Bed

Affinity Four Birthing bed Delivering Safety

ENTERPRISE with people in mind

Ave 2 Birthing Bed. Welcome to the world

Centrella Smart+ Bed Because life-altering moments deserve elevated care

Centrella Smart+ Bed. Because life-altering moments deserve elevated care

AvantGuard bed Safety by design. Information

Mechanical Ceiling/Floor Transfer (Hoyer)

Instruction for use and trouble shooting guide

Birthing Bed AVE 2. Welcome to this world child

Ampera bed. Trusted performance for all care environments

SMP 385MT. Solutions Start Here... Solutions Start Here USER & MAINTENANCE MANUAL

Eleganza 3XC. Designed for ICU

InTouch Critical Care Bed. Basic needs. Simplified care. Exceptional outcomes.

Introduction. Welcome to Human Care.

The Hill-Rom 900 bed Simply efficient

Protection and Convenience For You and Your Patient

Medical furniture OPTIMA OBSTETRIC BED

MMO

EasyCare Maximizing Care, Comfort and Safety

Citadel Bed Frame System

Medical. InTouch. Basic Needs. Simplified Care. Exceptional Outcomes. Stryker InTouch Critical Care Bed

LikoGuard Overhead Lift System Enhancing patient safety

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

Velino. by Haelvoet HOSPITAL - NURSING HOME FURNITURE

Image 3. exclusive design to meet all your needs

R E C L I N E R S E A T I N G

Völker Long Term Care beds Providing a range of care options

Wissner-Bosserhoff Aged Care Furniture

User Manual for Spirit Beds

Lift Repositioning and Turning Accessory Operating Instructions

User Guide (0108) Barton Ceiling Track Lift

More comfortable childbirth

BariMaxx Active Therapy System

HSC 360b Move and position the individual

Ceremonial Bugle Operation Manual and Military Funeral Honors Guide

Opera. With people in mind

Prime TC. Transport Chair. Patient Transport Redefined.

Module 6: Client Moving Techniques * Terms marked by an asterisk are defined in the Glossary

CARENDO ERGONOMIC HYGIENE CHAIR WITH UNIQUE CARE RAISER

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

*Before instructing class carefully review Transfer Sheet User Guide*

PURPOSE: POLICY: FACTS:

Eleganza 5. art of nursing

Citadel Plus Bariatric Care System

Microprocessor Nurse Call System In-Service Training

Redefining Patient Handling. prevention

Park Nicollet Health Services

Activity 3: TRANSFER TO A WHEELCHAIR Future tense

LF1090 BARIATRIC PATIENT LIFT

LF1090 BARIATRIc. USeR MANUAL. LF1090-INS-LAB-RevD GF Health Products, Inc.

Caution! triangles are used to warn of situations that demand extra care and attention.

Solutions to Challenges Associated with Bariatric Patients

Guidelines. Homes. Ergonomics. Musculoskeletal Disorders. for Nursing. for the Prevention of

ATTENTION ALL C.N.A S

VAN WERT COUNTY HOSPITAL. Policy/Procedure: Interdepartmental No.: N Issue Date: 6-90 By: Nursing No. of Pages: 9

2016 School District of Pittsburgh

Streamline. IV Suspension System. Reliabilit y Versatilit y Cost Savings. Reliability Versatility Cost Savings

2010 Innovative Uses and Tips for Safe Patient Moving Equipment: Safe Patient Moving: the Keys to the Kingdom: Learning Objectives

VHA Safe Patient Handling and Mobility Algorithms (2014 revision) Algorithm 4: Reposition in Chair: Wheelchair, Dependency Chair or Other Chair

Introduction. Welcome to Human Care.

CARINO. with people in mind

User-Service Manual Joerns Assist Handle Model F025

Pressure IQ Evolve Mattress Replacement System USER MANUAL

CArEnDO ElECtrIC HyGIEnE CHAIr

To provide the appropriate way of carrying and/or moving of a patient ensuring the patient's safety

Functional Abilities / Core Performance Standards

Understand nurse aide skills needed to promote skin integrity.

The Ergonomics of Patient Handling

OR Positioning and Pressure Injury Prevention. September 13, Ann N. Tescher, APRN CNS, PhD, CCRN, CWCN Debra L.

Redefining Patient Handling. prevention

mobilia The Sitting and Rising Bed

GUIDELINES FOR THE USE OF ASSISTIVE TECHNOLOGY EQUIPMENT IN COMMUNITY INPATIENT UNITS

Purpose and Objectives

CLINICAL CARE SEATING Comfort Functionality Durability

Isolette TI500 Neonatal Transport

STUDENT NURSE POSITION DESCRIPTION

NHS Training for Physiotherapy Support Workers. Workbook 15 Transfers

See the Pressure you re up against...

Moving and Handling. Study guide

Indications for Calling A Code Blue or Pediatric Medical Emergency

Bariatric. Care Solutions

CARINO. with people in mind

In Person: Anthropometric Measures and Functioning

Chapter 11. Preventing Falls. Copyright 2019 by Elsevier, Inc. All rights reserved.

This report summarizes the ergonomic risk assessment conducted at a Hospital August 2001.

Introduction. Welcome to Human Care.

Introduction to Technology in the Penobscot Pavilion

EarlySense InSight. Integrating Acute and Community Care

Chapter 14. Body Mechanics and Safe Resident Handling, Positioning, and Transfers

Olympia. Soft & XLow. by Haelvoet. T +33 (0) F + 33 (0)

Quality Care is. Partners in. In-Home Aides. Assisting with ambulation and using assistive devices: - March

Safe Patient Handling:

! "#"!$%&'()*%!+!,-)$(!.%/0%&1! $2345!67!869:59:;!!!! )/%1A""#$%&'()$"%&*"+,(-".'')''/)&-"0)12)'-" 3"

Bariatric Bed Shown with options

Home Care Aide Skills Checklist

Taking Care Of Your Back Manual Handling. Clinical Skills

Handling the Bariatric Patient: Ergonomic Issues HoverTech International All Rights Reserved

NEVADA MOCK SKILLS: February 15, 2018 Page 2

Transcription:

Hill-Rom Advanta 2 Bed Tips Simply Intuitive FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE ADVANTA 2 BED, SEE USER S MANUAL. 1

Three-Mode Bed Exit System (Patient Position Monitor) The Bed Exit Alarm will notify the caregiver when: + + Patient Position: patient moves toward either siderail or moves away from the head section, such as sitting up in bed. + + Exiting: patient moves away from the center of the bed towards an egress point. + + Out of Bed: patient s weight shifts significantly off the frame of the bed. To Activate: Make sure the patient is centered in the bed and aligned with the hip locator. Press the Enable control until the indicator comes on. Press the applicable mode control. When the system beeps one time and the indicator stays on solid, the system is armed. 2 To Reset or Deactivate: Press the Enable control until the indicator comes on. Press any mode control until the indicator goes off. To Adjust the Alarm Volume: Make sure the patient is on the bed and the system is armed. Press the Enable control until the indicator comes on. Press and release the Volume control until the applicable volume indicator comes on.

SafeView System The SafeView Alerts show a steady green when the Bed Exit Alarm System is active and all of the conditions below are met: + + The bed is in the low position. + + The siderails are up: at least the two head siderails and possibly one or both foot siderails. + + The brake is set. If one or more of these conditions are not met, the Alerts flash yellow. The 30 Head Angle Alarm will cause the lights to flash yellow even if the SafeView Alerts are not active. A technical problem may cause the lights to flash yellow and green; in which case, call your facility authorized maintenance person. 3 To Deactivate Alerts only: Make sure the Bed Exit Alarm System is not active. Press and release the Enable control. Press and hold the applicable Bed Exit Mode control. Continue to press the Bed Exit Mode control, and press the Volume control for approximately three seconds. The Alerts will flash green for three seconds to let you know the configuration is set. The Bed Exit Alarm System will be active, and the Alerts will be off.

Head Angle Alarm The angle of the head section is continuously displayed on the caregiver pod. When set, the Head Angle Alarm control notifies caregivers if the head section goes below 30 with these indicators: + + The alarm display will flash continuously. + + An audible alarm will come on. + + The alarm indicator will flash. + + If installed, the SafeView Alerts lights will flash yellow. + + The caregiver pod display flashes five times. 4 To Set the Alarm: Raise the head section to the applicable position above 30. Press the Enable control. Press the Alarm control. The alarm indicator will come on. To Turn Off the Alarm: Raise the head section above 30. To Deactivate the Alarm: Press the Enable control. Press the Alarm control. The alarm indicator will go off. NOTE: When the bed operates on battery power, the display will be off and the alarm will not work.

Lockout Controls Located on the caregiver siderail control panel, the lockout controls allow the caregiver to disable the bed articulating functions to prevent patient positioning features from being used. Features that can be locked out: + + The Bed Up/Down lockout also locks out the Trendelenburg and Reverse Trendelenburg controls. + + The Head or Knee lockout also locks out the Chair and Bed Flat controls. + + The Knee lockout also locks out the Foot controls. To Activate: Press and hold the Lockout control, and then press the applicable control. Both patient and caregiver controls are locked out. An audible alarm sounds when a lockout is activated. An LED on the control panel comes on when a lockout is activated. To Deactivate: Press and hold the Lockout control, and then press the applicable locked out control. 5

Bed Flat Control The Bed Flat control allows a caregiver to easily return the sleep deck to a flat position (head and knee section down and foot section up) from any articulated position. The Bed Flat control only returns the sleep deck to a flat position; it does not change the angle of the bed. To Activate: Press and hold the Bed Flat control. When all sections are flat, the system stops. 6

Trendelenburg and Reverse Trendelenburg Controls The Trendelenburg control raises the foot end of the bed relative to the head end while Reverse Trendelenburg raises the head end of the bed relative to the foot end. The controls are on the head siderails and can be activated at any bed height. The Trendelenburg and Reverse Trendelenburg Line-of-Site Angle indicators are in the footend siderails. A cardiac arrest board (or the headboard in its place) is required. To Activate: Press and hold the Trendelenburg or Reverse Trendelenburg control to go into the applicable position. To Deactivate: Press the opposite control to return to the level position or raise or lower the bed fully. 7

Emergency CPR Control The CPR release allows the head section to lower and is gas assisted to cushion the movement and can be used when power is not available. The Emergency CPR control handles are located at the head end of the bed, under each corner of the sleep deck. To Activate: Pull and hold the CPR control handle with one hand. Let the head section come to a stop in the flat position. Release the CPR control handle when the head section is flat. The head section actuator is automatically re-enabled after the CPR control handle is released. 8

Vascular Position The Vascular Position allows for the patient s legs to be placed above the level of their sternum without placing the bed in the Trendelenburg position. To Activate: Press the Foot Up control. To Deactivate: Press the Foot Down control to return to flat position. 9

Foot Extension (Bed Extender) This foot or bed extender allows the foot section to extend 3" (7.6 cm). To Extend: Grasp the control bar located under the bed frame, below the footboard. Push up on the control bar. Pull the foot section out, then release the control bar. Continue to pull on the foot section until it locks into position. When the foot section is extended, insert the mattress foot extender pad between the mattress and the footboard. To Retract: Remove the mattress foot extender pad. Grasp the control bar located under the bed frame, below the footboard. Push up on the control bar. Push the foot section in, then release the control bar. Continue to push the foot section in until it locks into position. 10

Dining Chair Position The Dining Chair Position control allows the caregiver to put the bed in an upright position. The controls are located on the head siderails. When activated, the bed will articulate to a maximum of 65 for the head section, 19 for the knee section, and -12 for the foot section. To Activate: Set the brake. Press the Dining Chair Position control. The patient deck moves to the chair position. To Return to Flat Position: Press the Bed Flat control to return the sleep deck to the flat position. WARNING: Check at regular times to make sure the patient remains correctly positioned. The use of pillows can help maintain side-to-side positioning. Injury to the patient may result from improper positioning. 11

FullChair Patient Positioning Mechanism The FullChair Patient Positioning Mechanism allows the caregiver to place the patient in a fully seated position without having to remove the patient from the bed. To Activate: Set the brake. Press the Dining Chair Position control. The patient deck transitions to the chair position. Once the bed has finished traveling, press the Reverse Trendelenburg control until the applicable position is reached. To Return to Flat Position: Press the Bed Flat control to return the sleep deck to the flat position. Press the Trendelenburg control to return the bed frame to the level position or fully lower the bed. WARNING: Check at regular times to make sure the patient remains correctly positioned. The use of pillows can help maintain side-to-side positioning. Injury to the patient may result from improper positioning. 12

Automatic Contour Feature The automatic contour feature is designed to help keep the patient from sliding down in bed and to provide automatic comfort level positioning by raising the head section and the knee section simultaneously. To Activate: Press the patient Head Up/Down control. The automatic contour feature is active only when both the head section and knee section are not locked out. When the head section is locked out, the knee section can be raised or lowered by using the Knee Up/ Down control. 13

Zeroing the Scale The scale should be zeroed prior to placing a patient on the bed. + + Be sure to put ALL linens, pillows, and equipment on the bed prior to zeroing the scale. How to Zero the Scale: Press and hold the Zero control until the Hands Off indicator flashes. Release the button. The display will show CALC or ---- until the zero sequence is complete. Then, the display will show 0.0. 14

Weighing the Patient Be sure the scale has been zeroed with linens, pillows, and other equipment on the bed prior to weighing the patient. How to Weigh a Patient: Make sure the patient is centered on the bed. Ensure the bed is clear of all obstructions (lines, tubing, walls, etc). Press the weigh button until the Hands Off indicator flashes, then release the button. The weight will show in either pounds (lb.) or kilograms (kg). 15

Line Manager The Line Manager helps to keep lines (such as IV fusion lines, suction lines, oxygen lines, etc.) together and away from the articulating frame. A Line Manager is on each head siderail. Observe lines closely during articulations. Always use good line management techniques, particularly as the head section rises. 16

Care Grip Hand Hold The ergonomically designed Care Grip Hand Hold helps assist the patient during ingress and egress and to help a patient position themself in bed. The Care Grip Hand Hold is located on both head siderails. 17

Hill-Rom Advanta 2 Bed Tips Simply Intuitive TO USE OUR TIPS ON YOUR SMART PHONE, SCAN THE QR CODE BELOW. Hill-Rom reserves the right to make changes without notice in design, specifications and models. The only warranty Hill-Rom makes is the express written warranty extended on the sale or rental of its products. 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. ORDER NUMBER 187021 rev 1 27-MAY-2014 ENG US Zinc Number US-AC-0414-0181 www.hill-rom.com USA 800-445-3730 CANADA 800-267-2337