Eleganza 5. art of nursing

Similar documents
Eleganza 3XC. Designed for ICU

Image 3. exclusive design to meet all your needs

Safer mattresses. Effective and proven pressure ulcer prevention & therapy

Birthing Bed AVE 2. Welcome to this world child

Affinity Four Birthing bed Delivering Safety

Medical furniture OPTIMA OBSTETRIC BED

Simply Intuitive. The Hill-Rom Advanta 2 Bed

Simply Practical. The Hill-Rom CareAssist ES Hospital Bed

EasyCare Maximizing Care, Comfort and Safety

ENTERPRISE with people in mind

CArEnDO ElECtrIC HyGIEnE CHAIr

Ave 2 Birthing Bed. Welcome to the world

AvantGuard bed Safety by design. Information

Velino. by Haelvoet HOSPITAL - NURSING HOME FURNITURE

Hill-Rom Advanta 2 Bed Tips Simply Intuitive FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE ADVANTA 2 BED, SEE USER S MANUAL.

Instruction for use and trouble shooting guide

smart technologies Neonatal incubator from standard to intensive care

Ampera bed. Trusted performance for all care environments

The Hill-Rom 900 bed Simply efficient

CARINO. with people in mind

THE INTERVENTIONAL PATIENT HYGIENE COMPANY

ConCerto Shower trolley

Protection and Convenience For You and Your Patient

Opera. With people in mind

CARINO. with people in mind

Bariatric. Care Solutions

Centrella Smart+ Bed Because life-altering moments deserve elevated care

Centrella Smart+ Bed. Because life-altering moments deserve elevated care

Wissner-Bosserhoff Aged Care Furniture

showering solutions Create a safe, efficient and dignified care environment

Introduction. Welcome to Human Care.

CARINO HEIGHT ADJUSTABLE HYGIENE CHAIR

InTouch Critical Care Bed. Basic needs. Simplified care. Exceptional outcomes.

Propad MATTRESS OVERLAYS, CUSHIONS AND ACCESSORIES MSS. Distributed by:

smart technologies Neonatal incubator from standard to intensive care

Redefining Patient Handling. prevention

Völker Long Term Care beds Providing a range of care options

Medical. InTouch. Basic Needs. Simplified Care. Exceptional Outcomes. Stryker InTouch Critical Care Bed

Citadel Plus Bariatric Care System

Redefining Patient Handling. prevention

More comfortable childbirth

How effective is your pressure reducing surface?

Functional elegance in nursing care. movita movita casa Nursing home beds

MMO

LikoGuard Overhead Lift System Enhancing patient safety

What will be covered in this NAEP workshop?

CARMINA BARIAtRIC shower CoMMode ChAIR

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

CARENDO ERGONOMIC HYGIENE CHAIR WITH UNIQUE CARE RAISER

The birth of a new era Excellent neonatal respiratory support at your fingertips DRÄGER BABYLOG VN500

Understand nurse aide skills needed to promote skin integrity.

See the Pressure you re up against...

Primus. Your personal anesthesia assistant. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

GE Healthcare. B40 Patient Monitor Connecting intelligence and care

Olympia. Soft & XLow. by Haelvoet. T +33 (0) F + 33 (0)

Expand your possibilities

Functional elegance in nursing care. sentida Low nursing beds

Chapter 14. Body Mechanics and Safe Resident Handling, Positioning, and Transfers

This report summarizes the ergonomic risk assessment conducted at a Hospital August 2001.

FlexoStretch. Product Description. Instruction Guide

mobilia The Sitting and Rising Bed

Bed Rail & Inspection Policy and Procedure Checklist

Bedside cabinets and overbed tables

Solutions to Challenges Associated with Bariatric Patients

A Patient s Guide to Pressure Ulcer Prevention

XO 5800 Series SEATING COLLECTION.

... Top Quality Assurance Bizerba CWE Checkweigher

POLICY FOR THE USE OF BEDRAILS AND BEDRAIL COVERS

MySign S, the original setting new standards in pulse oximetry

9/17/2015. Bed Rail Safety A Clinical Process Guideline. Background. Federal Nursing Home Reform Act

Bed Rail Safety A Clinical Process Guideline. Laura Funsch, RN, BSN, MS, Director of Regulatory Strategy

Citadel Bed Frame System

GE Healthcare. Dash 3000, 4000 & High-acuity mobile patient monitoring

OR Positioning and Pressure Injury Prevention. September 13, Ann N. Tescher, APRN CNS, PhD, CCRN, CWCN Debra L.

Pressure IQ Evolve Mattress Replacement System USER MANUAL

SMP 385MT. Solutions Start Here... Solutions Start Here USER & MAINTENANCE MANUAL

MySign S, the original setting new standards in pulse oximetry

Setting a new standard for performance, safety and simplicity

Guidelines. Homes. Ergonomics. Musculoskeletal Disorders. for Nursing. for the Prevention of

Taking Care Of Your Back Manual Handling. Clinical Skills

Always at Hand for Smooth Transfers

Information For Patients

Bed Rail Entrapment Risk Notification Guide

GE Healthcare. Timeless exc ellence. CARESCAPE * V100 - Vital Signs Monitor

Guidelines for the Prevention of Pressure Ulcers

At your side in intensive care

THE MODERN WORKSPACE BY ENTRAWOOD

PURPOSE: POLICY: FACTS:

Information on How to Prevent Pressure Ulcers ( Bedsores ) for Patients, Relatives and Carers in Hospital and in the Community

Alaina Tellson, PhD, RN-BC, NE-BC

BED RAIL SAFETY 9/15/2015. A Clinical Process Guideline. Background. Federal Nursing Home Reform Act

Safe Patient Handling:

Lateral Transfers Boosting Turning Positioning Proning

PRESSURE ULCER PREVENTION SIMPLIFIED

Safe moving and handling guidance

VHA Safe Patient Handling and Mobility Algorithms (2014 revision) Algorithm 4: Reposition in Chair: Wheelchair, Dependency Chair or Other Chair

latera thema Furniture for an ambience worth living in

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

Isolette TI500 Neonatal Transport

GE Healthcare. B20 Patient Monitor 1 Connecting intelligence and care.

Transcription:

Eleganza 5 OŘEZ OŘEZ art of nursing

Art of safety Art of mobilization Art of turning 2 LINET Eleganza 5

Art of positioning Art of communication LINET Eleganza 5 3

Art of turning HANDLE YOUR PATIENT WITH GENTLE CARE AND SAVE YOUR BACK! Innovative tilting technology with smooth columns helps to turn the patient gently with less physical effort. The nurse will carry out routine nursing procedures ergonomically and effortlessly. Improves pressure ulcer prevention regular patient positioning is therefore easy. New technology: smooth bed tilting for even more sensitive care. Tested in practice Empirical measurement showed that the lateral tilt works and helps reduce the effort exerted when changing bedding on hospital beds by an average of 30%. LINET, CASRI certified procedure $ 7 billion annual cost of back problems among nursing staff* 4 * blog.nurserecruiter.com, Bureau of Labor Statistics USA

15 LEFT, 15 RIGHT, DONE! 35,000 reported musculoskeletal injuries of nursing staff in the USA in 2013.* The Eleganza 5 brings change! To positioning To bed making To bed changing To hygiene The lateral tilt for ergonomically correct care The traditional way of turning the patient can lead to back injury HANDS-FREE TILT The hands-free operation using the foot controls increases the efficiency of the atraumatic patient turn method. Both of the nurse s hands are free to devote full attention to the patient without any effort whatsoever. LESS SKIN DAMAGE AND ROUGH HANDLING MINIMUM PHYSICAL EFFORT, BACK INJURIES AND MENTAL STRESS FEWER WORK INJURIES AND WORK DISABILITY = COST SAVING LINET Eleganza 5 5

Art of safety MULTIPLE SAFETY: SOPHISTICATED SAFETY FEATURES CONTROLLED BY THE MONITORING SYSTEM. Siderails Concept Multizone Bed Exit Alarm Lowest Bed Height SAFETY UNDER CONTROL The BedMonitor system continuously monitors the main safety features of all beds in the department. Staff monitor the information on the display device (PC, tablet or mobile phone). 6 LINET Eleganza 5

30 Degree Autostop SIDERAILS CONCEPT Reduced side space needed for siderails release. Smooth release by Soft Drop. Minimum entrapment risk. Siderails down sensors. I-BRAKE The automatic brake prevents falls caused by the unstable bed, especially during bed exit. SAFESTOP Prevention of injuries due to crushing by the lowered mattress platform. SafeStop i-brake 65% of falls in hospital are bed related* MULTIZONE BED EXIT ALARM Fall prevention by monitoring the patient s motion activity and presence in the bed. Two modes are used to set up the monitoring depending on the risk level assessment. 30 DEGREE AUTOSTOP The automatic backrest stop at 30 degrees helps to improve respiration. LOWEST HEIGHT The lowest bed height helps to minimize the severity of fall consequences. * Thomayer Faculty Hospital, Prague, Czech Republic, 2005 7

Art of mobilization NEW PROGRESSIVE FEATURES WORK IN SYMBIOSIS FOR EARLY PATIENT MOBILIZATION. reduces bed exit effort by 50% 3 2 1 QUICKER RECOVERY IN A SAFE WAY REDUCED PHYSICAL EFFORT FOR STAFF DURING MOBILIZATION LOWER TREATMENT COSTS DUE TO SHORTER HOSPITALIZATION 8 LINET Eleganza 5

SYMBIOSIS OF 3 ELEMENTS When exiting the bed the patient has 3 big aids to put him back on his feet. Mobilization can begin soon so the patient can gain in self-confidence. This also removes the physical strain on staff. 1 2 3 Mobi-Lift UNIQUE! The patient controls the bed height using the Mobi-Lift handle. MobiRails Ergonomically shaped handles in the siderails. Lateral Tilt The height setting and side tilt will assist the patient s bed exit. STANDARD BED VERSUS MOBILIZATION FUNCTION Tested in practice The measurement of active mobilization using vibration belts ( a motion capture posture assessment harness ) on a standard bed and on a bed equipped with the lateral tilt or Mobi-Lift handle*. Number of advers movements 50 40 30 20 10 The number of adverse movements a patient needs to make when standing up on a standard bed is more than 50% greater when compared with a bed equipped with a lateral tilt or Mobi-Lift handle. 0 Standard bed Lateral tilt Mobi-Lift LINET Eleganza 5 * CENTRE OF EXCELLENCE IN POSTURE, MOVEMENT & HANDLING; Postural risk reduction and the electric profiling bed; Birmingham City University 9

Art of positioning MULTI-SECTION FRAME DESIGN: ALLOWS UNLIMITED PATIENT COMFORT AND IMPROVES NURSING EFFICIENCY. CARDIAC CHAIR POSITION Provides relief during respiratory problems and is very pleasant for the patient when reading, eating or watching television. a nurse lifts 1.8 tons during a typical 8-hour shift* FOWLER POSITION 30/30 WITH ERGOFRAME Equal pressure distribution for skin damage prevention. Minimized friction and shear effect during thighrest and backrest elevation. Less pressure load on the tissue due to the extended pelvic area space. 10 * Nelson, A., Baptiste, A., Evidence-based practices for safe patient handling and movement. Online Journal of Issues in Nursing, 2004

TILTABLE POSITION Improves the patient s breathing and maintains arterial blood pressure at a more stable range. VASCULAR POSITION A position with legs at heart level: optimized venous return and positive impact on swelling (oedema) reduction. Help in back ache relief. FULL VASCULAR POSITION Full access for skin inspection & wound care in the heel area. Passive Leg Raise (PLR) a clinical technique only used when ordered by a physician to assess fluid status without the use of a central line. LINET Eleganza 5 11

Art of communication SMART TECHNOLOGY AND BED CONNECTIVITY FOR A NEW WAY OF COMMUNICATION. Logical display of all information Nurse close to the patient Preselected functions and safety features Intuitive and single-level controls Display visible from all angles Ergonomics operating the bed and further equipment from one point iboard 1 control point for the staff 12 LINET Eleganza 5

BEDMONITOR SYSTEM Using sensors built into the bed, the system monitors the settings of the safety parameters. Allows long-term monitoring of the bed settings and adjustment to the individual needs of patients. The relevant information can be assessed and the effectiveness increased. An effective risk management tool in departments. CONNECTIVITY Using the integration module the bed sends the necessary data to the hospital information system. Wifi or LAN connection. Safety parameters (bed settings) Technical information (component status and history) Monitoring of bed function use (effectiveness) ibed DIAGNOSTICS Service Easy detection of the defects Sends data to LINET service Stores data from bed Future evolution Fast routine maintenance Routine maintenance check lists Spare parts on-line ERGONOMIC AND SIMPLE CONTROLS HIGH TECHNOLOGICAL LEVEL, EFFECTIVE MANAGEMENT EQUIPMENT, COST SAVING LINET Eleganza 5 13

Eleganza 5 14 LINET Eleganza 5

Innovation with human touch LINET Eleganza 5 15

Art of nursing Daily, 9,000 healthcare workers sustain a disabling injury while performing work-related tasks. Deborah Brown RN, BSN* i-drive Power = ZERO effort 16 * America Journal of Critical Care LINET Eleganza 5

i-drive POWER The intelligent accelerator optimizes the drive speed in different drive situations. Safety Sense Control This unique feature avoids the risk of accidental activation or misuse. In principle, the bed cannot be driven without the user s hand on the Safety Sense drive area designed also as a driving handle. X-RAY Thanks to the X-ray transparent mattress platform and special bed construction, lung X-rays can be taken without any need for physical handling of the patient. Lateral insertion of the cassette facilitates an optimum approach. SCALES The integrated scales display the actual patient weight and record the selected weight values. The system allows items to be removed or added without affecting the weight data. LINET Eleganza 5 17

Art of comfort MATTRESS TO MEET YOUR NEEDS Selecting a suitable mattress can prevent pressure ulcers or treat them effectively. The mattress can also significantly affect the patient s bed comfort. OPTICARE An integrated low air loss system with an automatic pressure setting, automatic foot extension and bottoming out detection. CLINICARE 100HF This reactive mattress combines the benefits of passive and active systems. It also offers microclimate management. VIRTUOSO The active mattress works on the principle of zero pressure alternation in air cells. It is fully compatible with the bed. CLINICARE 30 The thermoelastic foam mattress offers high reclining comfort. The Clima increases the anti-decubitus effect. CLINICARE 20 The top of the passive mattress surface is sculpted for air circulation and better pressure distribution. 90% of pressure ulcers can be avoided* 18 * EPUAP, Declaration of Rio, October 2011

EASY REPOSITIONING All you need you have: 1 2 3 Suitable anti-decubitus mattress Ergoframe Lateral tilt USB CHARGER The patient has a USB charger in the backrest for mobile phones and other devices. ELECTRIC EXTENDER An easily adjustable platform length for all patient categories. Provides enhanced patient well-being and possible help in the treatment of achilles tendon contracture. LINET Eleganza 5 19

Practical details 1 Foot controls Practical foot controls for the easy handling of patients. 2 Horizontal corner bumpers Protect the bed. 3 Mobi-Lift Helps patient to control bed hight. 4 Mechanical CPR Additional feature of electrical CPR for urgent use. 2 3 5 Integrated patient controls With illuminated keyboards. 6 Bed ends Ergonomically shaped bed ends for easy transport. SAFE BED EN 60601-2-52 COMPLIANT Certificates LINET is a company certified under European standards and quality systems: EN ISO 9001:2000, EN ISO 13485:2003. Products are manufactured in accordance with the European standards for medical technology and hospital beds: EN 60601-1, EN 60601-1-2, EN 60601-1-4, EN 60601-2-52, EN ISO 14971, 93/42/EEC, 90/384/EEC. 20 LINET Eleganza 5

6 5 4 1 Electric parameters Power supply Maximum input max. Protection against water and dust Type of protection against electrical current Level of protection against injury from electrical current Electric motor operation mode (load factor) 230 V AC, 50/60 Hz 370 VA IP X4 Class I Applied part type B max. 2 min ON /18 min OFF Technical parameters External dimensions Mattress dimensions Max. siderails height Height adjustment 219 100 cm (shortest position) 241 100 cm (longest position) 208 90 cm 45 cm Lateral tilt ±15 43.5 81.5 cm TR/ATR tilt 14 /14 Safe working load Maximum patient weight 250 kg 185 kg LINET Eleganza 5 21

Art of LINET BEFORE YOU DECIDE Your investment should be effective and respect your needs and options. Therefore we offer: A bed fund analysis and suitable bed configuration. Visualization, colour concept, design bed. Optimal funding solution. Bed and mattress rental service. SUPERIOR Choice of suitable mattress, accessories and further equipment. WARRANTY SUPERIOR WARRANTY SUPERIOR WARRANTY IT STARTS WITH THE BED PURCHASE We build long-term relationships and will help you to maximize profit from the bed purchase. Installation and training. Education for nurses. Quick service, regular maintenance. Superior guarantee service. 1,000,000 beds sold since 1952 22 LINET Eleganza 5

WHY CHOOSE A LINET BED LINET Group SE, with production plants in Germany and the Czech Republic, exports beds to healthcare and nursing facilities worldwide. The group is one of the biggest bed suppliers in Europe and ranks third in the US market. As well as bed quality, LINET Group SE also guarantees follow-up customer care. EXPERIENCE SPEAKS FOR US facebook.com/northwesternmedicine Northwestern Memorial Healthcare, Chicago, USA 499 Multicare LE beds, 2015 MOH Hospitals, Riyadh, Saudi Arabia 823 Eleganza 2 beds, 225 Eleganza Smart beds, 2015 LINET Eleganza 5 23

Eleganza 5 Quick and safe mobilization Improved work safety Maximum safety Saves valuable time Patient Ensures patient well-being Simple and easy work with the bed Staff Management An extremely acuity versatile bed, fully intelligent and compatible Major process improvement for hospital Effective management equipment = cost saving bed Members of LINET Group LINET spol. s r.o. Želevčice 5 274 01 Slaný Czech Republic tel.: +420 312 576 400 fax: +420 312 522 668 e-mail: info@linet.com www.linet.com LINET Art. nº 9601-1055_01 Edition 01/ 2018 Slight colour differences are possible. Change of technical parameters reserved.