Multi-Link. X2 ECG System. Choose flexibility and quality for your reusable and disposable single-patient-use leadwires

Similar documents
BUGS BE GONE: Reducing HAIs and Streamlining Care!

Transmission Based Precautions Literature Review: Management of Patient Care Equipment

The Role of Isolation and Contact Precautions in the Elimination of Transmission of MRSA

Infection Control and Prevention On-site Review Tool Hospitals

SBAR: Use of gloves for environmental cleaning

Healthcare-Associated Infections

CENTRAL SERVICE (CS) IS A VITAL DEPARTMENT IN ANY HOSPITAL

Implementing Technologies for the Reduction of Hospital Acquired Infections. AHCA 2015 October 12, 2015 / 1:00 2:00 pm

Isolation Gowns That Provide AAMI Level 1, 2 and 3 Protection

NOSOCOMIAL INFECTION : NURSES ROLE IN MINIMIZING TRANSMISSION

Environmental Cleaning. August 14, 2013

Healthcare Associated Infections Know No Boundaries: A View Across the Continuum of Care

Kristi Felix RN, BSN, CRRN, CIC, FAPIC Infection Prevention Coordinator Madonna Rehabilitation Hospitals

Infection Prevention Implementation and adherence to infection prevention practices are the keys to preventing the transmission of infectious diseases

LPN 8 Hour Didactic IV Education

Comply with infection control policies and procedures in health work

Infection Prevention, Control & Immunizations

Replaces: 08/11/16. Formulated: 1/2000 TRANSMISSION-BASED PRECAUTIONS

MHA/OHA HIIN Antibiotic Stewardship/MDRO Collaborative

A REVIEW OF ENVIRONMENTAL HYGIENE REQUIREMENTS

2014 Annual Continuing Education Module. Contents

Your Act! MRSA, C. diff, other harmful bacteria lurk in unexpected places

SOFT SURFACE BACTERIAL MANAGEMENT:

Taking Action to Prevent and Manage Multidrug-resistant Organisms and C. difficile in the Nursing Home: Part 3 Strategies to prevent

Infection Prevention and Control in Ambulatory Care Settings: Minimum Expectations for Safe Care

Proactively prevent HAIs with infection surveillance software

Babies, and Biofilms: An Outbreak of Pseudomonas aeruginosa in a neonatal intensive care unit

9/14/2017. Best Practices in Instrument Cleaning. Objectives. Healthcare-associated Infections

Infection Control Update for Nursing Homes. Survey and Certification Group Centers for Medicare & Medicaid Services

INFECTION C ONTROL CONTROL CONTROL EDUCATION PROGRAM

POLICY & PROCEDURE POLICY NO: IPAC 3.2

Minimum Criteria for Common Infections Toolkit. [Name] [Organization]

a. Goggles b. Gowns c. Gloves d. Masks

Infection Control in the Hearing Aid Clinic What is infection control & why should we care?

Cleaning and disinfecting patient care equipment is an important infection prevention strategy for patients receiving care in the home.

Identify patients with Active Surveillance Cultures (ASC)

Technical Bulletin. Summary...5. Background...2. Study Commissioned...2. Methodology...2. Results...3. Discussion...3. Cost Comparison...

Presented by: Mary McGoldrick, MS, RN, CRNI

Infection Control and Prevention On-site Review Tool Hospitals

ACG GI Practice Toolbox. Developing an Infection Control Plan for Your Office

(MRSA) De-isolation Procedure

May 9, Leslie Kux Associate Commissioner for Policy U.S. Food and Drug Administration 5630 Fishers Lane, Rm Rockville, MD 20852

TITLE: Double Gloves for Prevention of Transmission of Blood Borne Pathogens to Patients: A Review of the Clinical Evidence

Clostridium difficile

we ve got you COVERED.

Title: Length of use guidelines for oxygen tubing and face mask equipment

QUESTIONS PERTINENT TO PRODUCT SELECTION:

Objectives. Hot Topics in Infection Prevention and Control in Post Acute Care Settings. NADONA Infection Prevention and Control Webinar Series

Infection Prevention and Control and Antibiotic Stewardship: More than Counting Beans

Personal Hygiene & Protective Equipment. NEO111 M. Jorgenson, RN BSN

Infection prevention & control

An economic - quality business case for infection control & Prof. dr. Dominique Vandijck

Neysa Ernst RN, MSN and Mallory Reimers RN, MSN, ACCNS-AG

Accreditation Program: Hospital

Name of Assessor Unit Date. Element Yes No Action Needed

HOW CLEAN IS CLEAN? STRATEGIES FOR ENVIRONMENTAL CLEANLINESS IN THE AMBULATORY SETTING

Infection Control Prevention Strategies. For Clinical Personnel

Discussions and Activity at the Federal Level Regarding Management of Electronic Medical Equipment

Vancomycin-Resistant Enterococcus (VRE)

Key Scientific Publications

Clostridium difficile Infection (CDI) in children (3-16 years ) Transmission Based Precautions

HealthStream Ambulatory Regulatory Course Descriptions

New SGNA Standards Call for Expanded Infection Prevention Efforts in GI Endoscopy

BEHAVIORAL HEALTH & LTC. Mary Ann Kellar, RN, MA, CHES, IC March 2011

USING PROCESS EVALUATION TO INFORM PROGRAM DESIGN. A CASE STUDY OF THE EBOLA RESPONSE IN THE U.S. HEALTHCARE SYSTEM Monica LaBelle, PhD

RISK CONTROL SOLUTIONS

8. Droplet/Contact Precautions. 8.1 Introduction

Decreasing Nosocomial C. diff

Infection Control Prevention Strategies. For Clinical Personnel

AS/NZS 4187:2003 AS/NZS

Incident Annex 9 Biological. Coordinating Departments Accidental and Isolated Incidents. Department of Public Safety (Emergency Management)

Guidelines for the Management of C. difficile Infections in. Healthcare Settings. Saskatchewan Infection Prevention and Control Program November 2015

Counting the cost and value of hospital cleaning and disinfection

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

Infection Control in General Practice

Literature Review and Recommendations EMS Equipment and Transport Vehicle Cleaning and Disinfection EMS Bureau Protocol Review Steering Committee

Infection Prevention and Control Training

[] PERSONAL PROTECTIVE EQUIPMENT Vol. 13, No. 8 August 2009

08/09/ elements required for Infection to occur. Chain of Infection. Evolution of Standard & Transmission Based Precautions

Expand your possibilities

D Bringing you closer to your patients PATIENT MONITORING AND IT SOLUTIONS

PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards. Infection Prevention and Control: Personal Protective Equipment

5/9/17. Healthcare-Associated Infections Cultural Shift. Background. Disclosures and Disclaimers

Personal Protective Equipment Use for Patients with Clostridium difficile

Objectives. IPC Open calls - bi-weekly series. Introduction to Infection Prevention & Control (IPC) Open Call Series

An act to add Sections and to the Health and Safety Code, relating to health.

Enterobacteriaceae. Preventing the Spread of Carbapenemresistant. in LTCFs. Nimalie D. Sto ne, MD, MS CDC Division of Healthcare Quality Promotion

75,000 Approxiamte amount of deaths ,000 Number of patients who contract HAIs each year 1. HAIs: Costing Everyone Too Much

Dr. Schumacher Safety made simple

SECTION: PATIENT RELATED INFECTION CONTROL NUMBER: 2.1 TRANSMISSION BASED PRECAUTIONS

More Pathways To More Value

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings

Infection Control (F441) F Cindy Deporter DHSR

Why Does Hand Hygiene Matter? 1/26/2015 1

Engaging Patients in Hand Hygiene

Introduction to Infection Prevention and Control (IPC) Open Call Series #1 Surveillance

Navigating through Frontline Competencies, Training and Audits

Assessing Evidence of Transmission and End of Transmission of Carbapenemase Producing Enterobacterales 1 (CPE)

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157

HOSPITAL EPIDEMIOLOGY AND INFECTION CONTROL: SURGICAL SITE INFECTION REPORTING TO CALIFORNIA DEPARTMENT OF PUBLIC HEALTH

Transcription:

Multi-Link X2 ECG System Choose flexibility and quality for your reusable and disposable single-patient-use leadwires For more than a decade, our engineers have designed the only official, validated ECG supplies and accessories for GE Healthcare patient monitoring systems. Now, with our Multi-Link X2 ECG System, finding the right connection in your healthcare facility is no longer a concern. We are extending this expertise, knowledge, and focus on quality to several other major bedside monitoring platforms, by now offering ECG capital accessories and solutions for the following brands: GE Healthcare Our new Multi-Link X2 universally compatible trunk cables allow you to use the same leadwires throughout your facility, no matter which of these brands is in the room. Leadwires that move with the patient can help lower the rate of hospital acquired infections (HAI) by reducing cross-contamination. 1 Multi-Link X2 ECG System: your single-source solution for all ECG needs Unlike most other ECG solution providers, we offer both reusable and single-patient-use portfolios. Healthcare facilities, which have not yet transitioned to fully disposable ECG leadwires, can use our single-patient-use sets in high-risk patient care areas while continuing to utilize reusable sets throughout the rest of the facility. The Multi-Link X2 ECG System is your single-source solution for all ECG needs.

Why convert to disposable leadwires? Negative link between HAIs and reusable leadwires Bacterial contamination: 77% 2 Clinical studies focusing on disposable leadwires Growing evidence demonstrates that, even when appropriate cleaning protocols are in place, antibiotic resistant bacteria can survive on a large portion of a facility s reusable ECG leadwires. The University of Wisconsin cultured 100 clean, reprocessed leadwires and discovered 77% of them still showed signs of bacteria growth. 2 Some bacteria can survive for at least 5 weeks on surfaces of medical equipment, making them very difficult to kill. At the Bon Secours Cancer Institute at St. Francis Medical Center in Midlothian, VA, a 2-month zero infection rate was achieved when they added single-patient-use leadwires to their infection control bundle. 4 The Centers for Disease Control and Prevention (CDC) recommends healthcare facilities consider implementing patient-dedicated noncritical equipment, such as blood pressure cuffs or leadwires, to help manage the spread of multidrug-resistant organisms. 5 77% 0% 0% In a University of Wisconsin study, antibiotic-resistant bacteria were found on 77% of cultured ECG leadwires after they were cleaned and reprocessed. Bacteria strength: 5 weeks Some bacteria can survive for at least 5 weeks on surfaces of medical equipment after the initial outbreak has been eradicated. Impact of infection control bundle: 0% infection rate for 2 months and 5 months 4 When two hospitals implemented an infection control bundle, including disposable leadwires, one reported zero infection rate for 2 months and the other reported a 5-month zero infection rate as a result. Because they stay with the patient until hospital discharge, single-patient-use leadwires help mitigate patient cross-contamination. Removing the opportunity for bacteria to interact with multiple patients from the same leadwire can result in a reduction in cross-contamination in your healthcare facility.

Which option is best for your healthcare facility? Every healthcare facility is unique. That s why the Multi-Link X2 ECG System provides a robust offering of lengths, grabbers and snaps for both reusable and disposable configurations. Our unique system allows you to fully utilize either reusable or disposable leadwires, or use a mixture of both throughout your facility without experiencing compatibility concerns. Our bedside offering eliminates the need for pesky adapters, which are often misplaced or accidentally transferred with the patient. Our gray, reusable ECG trunk cables remain with the bedside monitoring system, eliminating the need for adapters.

Whole-house disposable leadwires Utilizing a disposable system throughout your entire healthcare facility can help you eliminate the possibility of cross-contamination from the reuse of ECG leadwires. Our versatile single-patient-use leadwires remain with the patient throughout their stay, even when transferred between departments with different monitoring solution brands no compatibility issues. Two different configurations for whole-house disposable leadwires Traditional configuration Bedside Extra-long leadwire configuration 12' 29" or 9" 9" 12' The traditional configuration utilizes a 12' ECG cable and 9" or shorter leadwire. This configuration features the same length cables and leads in a typical reusable set-up. Unlike a traditional configuration, the extra-long leadwire style utilizes a 9" trunk cable and 12' leadwire. This extra short, reusable trunk cable provides peace of mind knowing it is out of the patient s reach. short 9 trunk cable with a 5-lead extra-long disposable leadwire set

Partial-house disposable leadwires Unlike most other universal ECG systems, the Multi-Link X2 ECG System was designed with flexibility in mind, allowing healthcare facilities to use both reusable and disposable leadwires in different departments throughout their system. This helps healthcare facilities focus on single-patient-use leadwire solutions for the departments that need it most, while gaining support for a whole-house disposable solution in the future. Two different configurations for patrial-house disposable leadwires Reusable leadwire configuration Disposable leadwire configuration 12' 51" or less 12' 29" or 9" By utilizing 12' reusable Multi-Link X2 ECG trunk cables throughout your healthcare facility, you can use disposable* or reusable Multi-Link leadwires in every room. If a patient transfers from a department utilizing disposable leadwires, the leads can remain with them for the rest of their stay. *Extra-long disposable leadwires are not recommended for use with 12' trunk cables. Did you know? The back of all Multi-Link X2 Trunk Cables have easy-to-read laser printing, which includes the reorder number, lot number and, in some instances, lead configurations. The lot number is in a MMYYYY format to easily discern the age of your trunk cables.

Whole-house reusable leadwires The Multi-Link X2 ECG system is designed to also function fully independent of disposable leadwires. Our reusable platform is perfect for healthcare facilities that need a single-source supplier of ECG capital accessories without sacrificing value, quality or reliability. Plus, we offer an industry-best Double-Life warranty for all of our ECG capital accessories. After converting to reusable leadwires with the Multi-Link X2 ECG system, healthcare facilities are ready to convert to disposable leadwires when ready. Bedside reusable leadwires Did you know? 12' 51" or less Our reusable and disposable Multi-Link leadwires are stamped with the manufacturing date. The traditional configuration utilizes a 12' ECG cable and 51" or shorter leadwire. This configuration uses the same length cables and leads typically used in a reusable set-up. Month Year Now configure the right set-up for your facility Vital Signs ECG Configurator tool Want a snapshot of which leadwires to use with what trunk cables for the GE,,, and monitors throughout your healthcare facility? Access our handy ECG Configurator tool at carefusion.com/vscatalog and follow the easy, 5-step process to get the answers for your specific needs.

Multi-Link X2 ECG System SKUs, AHA Extra-long leadwire configuration Monitor input SKU Monitor Brand Leads Cable Length 2090100-041 or 5 2090100-04 GE 6 2090100-045 12 2090100-051 or 5 2090100-05 6 2090100-055 12 2090100-077 2090100-071 5 2090100-075 12 2090100-081 2090100-08 6 2090100-061 or 5 2090100-065 12 9 in/2 cm 9 in/2 cm 9 in/2 cm 9 in/2 cm 9 in/2 cm SKU Connection Style Leads Lead Length 20521-405 20521-406 5 Grabber 20521-408 V 208667-006 6 2052104-405 2052104-406 5 Snap 2052104-408 V 208649-006 6 12 ft/.6 m 12 ft/.6 m Extra-long disposable leadwires are only intended for use with the short, 9 in/2 cm reusable trunk cables listed on this page. For additional information please reach out to your Vital Signs Sales Representative. Traditional Configuration Monitor input SKU Monitor Brand Leads Cable Length 201700-001 or 5 2017005-001 GE 6 12 ft/.6 m 2017006-001 12 2090100-052 or 5 2090100-054 6 12 ft/.6 m 2090100-056 12 2090100-078 2090100-072 5 12 ft/.6 m 2090100-076 12 2090100-082 2090100-084 6 12 ft/.6 m 2090100-062 or 5 2090100-066 12 12 ft/.6 m SKU Connection Style Leads Lead Length 20521-005 20521-006 5 208667-00 6 9 in/100 cm 20521-008 Grabber V 20521-027 20521-007 5 29 in/75 cm 20521-006 208667-004 6 2052104-005 2052104-006 5 208649-00 6 9 in/100 cm 2052104-008 Snap V 2052104-027 2052104-007 5 29 in/75 cm 2052104-006 208649-004 6 For reusable ECG leadwire options please reach out to your Vital Signs Sales Representative.

References 1 Kelley LM, et al. Reusable Electrocardiography Lead Wires: A Potential Source of Infection. Cadence Health Delnor Hospital. 2 Jancin, B. Antibiotic resistant pathogens found on 77% of ECG lead wires. Cardiol News, March 2004, 2:14. Otter, J, French, G. Survival of Nosocomial Bacteria and Spores on Surfaces and Inactivation by Hydrogen Peroxide Vapor. J Clin Microbiol. January 2009; 47(1): 205 207. Published online 2008 Oct 29. doi: 10.1128/JCM.02004-08. 4 Brown, D. Disposable vs reusable electrocardiography leads in development of and cross-contamination by resistant bacteria. Crit Care Nurse, June 2011, 1():62-68. 5 Siegel JD, Rhinehart E, Jackson M, Chiarello L, and the Healthcare Infection Control Practices Advisory Committee. Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Healthcare Settings. https://www.cdc.gov/mrsa/healthcare/clinicians/ precautions.html. Published December 2007. Accessed March 14, 2017. CareFusion Vernon Hills, IL carefusion.com 2017 CareFusion Corporation or one of its subsidiaries. All rights reserved. Multi-Link, Vital Signs, CareFusion and the CareFusion logo are trademarks or registered trademarks of CareFusion Corporation or one of its subsidiaries. All other trademarks are property of their respective owners. VS804 (017/PDF)