DEFINITIONS GOOD SAMARITAN LEGISLATURE:

Similar documents
EARLY DEFIBRILLATION PROGRAM REGULATIONS

STUDENTS First Aid/Emergency Medical Care. Use of Automatic External Defibrillators (AEDs)

ENFIELD BOARD OF EDUCATION ENFIELD, CONNECTICUT. USE OF AUTOMATIC EXTERNAL DEFIBRILLATORS (AED s) BY SCHOOL PERSONNEL

AUTOMATED EXTERNAL DEFIBRILLATOR (AED) PROGRAM

P.L.2012, CHAPTER 6, approved May 2, 2012 Senate, No. 852

AUTOMATED EXTERNAL DEFIBRILLATOR Policy Code: 5028/6130/7267

CUMBERLAND PUBLIC SCHOOLS

a. is used to administer an electric shock through the chest wall to the heart;

PUBLIC ACCESS DEFIBRILLATION

PUBLIC ACCESS OF DEFIBRILLATION AND AUTOMATED EXTERNAL DEFIBRILLATOR POLICY

Emergency Treatment (AED)

4. In most schools the plan should be that a witness calls the front office ASAP, and staff there will:

TECUMSEH PUBLIC SCHOOLS Medical Emergency Response Team (MERT)

Policies Middletown Public Schools No AED School-Based Public Access Defibrillation Program

Automated External Defibrillator (AED) Policy and Procedure 2017

Public Access Defibrillation

IMPLEMENTATION PACKET

SAMPLE AED PROCEDURE

TAMPA ELECTRIC COMPANY ENERGY SUPPLY AUTOMATIC EXTERNAL DEFIBRILLATOR (AED) PROGRAM

3-28 Physical Fitness Facility Medical Emergency Preparedness

SPRAGUE SCHOOL DISTRICT Baltic, Connecticut ADMINISTRATIVE REGULATIONS REGARDING AUTOMATIC EXTERNAL DEFIBRILLATORS

Early Defibrillation Program Registration Guidelines

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

AUTOMATED EXTERNAL DEFIBRILLATOR IN THE SCHOOL SETTING

HEALTH AND SAFETY CODE SECTION

ACCIDENT AND ILLNESS PREVENTION PROGRAM (AIPP)

105 CMR is adopted under the authority of M.G.L. c. 111, 3 and 201, and St c. 324.

Automatic External Defibrillator (AED) And Training Grant Program. For Community and Recreation Facilities 2015

Fennville Public Schools Emergency Response Program GUIDELINES

Draft Defibrillator Information and Support Procedures. Work Health and Safety Directorate

105 CMR: DEPARTMENT OF PUBLIC HEALTH

Supercedes/Updates: 98-10, 06-03, 07-04

AUTOMATED EXTERNAL DEFIBRILLATOR PROGRAM

Use of Automated External Defibrillators (AEDs) Procedure Page 1 of 5

HEART SAFE SCHOOLS Project ADAM Wisconsin 1

Resuscitation Council (UK) Guidelines for the use of Automated External Defibrillators SUPERSEDED

Illinois Compiled Statutes Civil Immunities Good Samaritan Act 745 ILCS 49/

Wade Gordon Director of Safety and Security

American College of Surgeons Bleeding Control Legislative Toolkit

FIRST AID GUIDELINES UOW

Workplace Emergency Preparedness Seminar. Trained. Empowered. Prepared.

Basic Life Support (BLS)

BP U.S. Pipelines & Logistics (USPL) Safety Manual Page 1 of 7

Bench. Deacon s MEDICAL RESPONSE. the. I For America s Churches and Related Ministries from Brotherhood Mutual and Its Agents

The Newcastle upon Tyne Hospitals NHS Foundation Trust. First Aid Policy

First Aid, CPR and AED

Is Your Company in Compliance with OSHA Standards for First Aid Training and Emergency Preparedness?

Program Planning and Implementation Guide EMS

2.1 This procedure is applicable from 1st August 2015 and applies across all of the University s campuses.

FLORIDA DEPARTMENT OF CORRECTIONS OFFICE OF HEALTH SERVICES HEALTH SERVICES BULLETIN NO Page 1 of 8

Toolkit. Minnesota Department of Health and American Heart Association

Basic Life Support and Safe Use of an Automated External Defibrillator

CORPORATE SAFETY MANUAL

Orientation Instructions 1. Please read through the slides. 2. Click on the survey monkey and complete survey with all demographic info and questions

RIVER EDGE BOARD OF EDUCATION FILE CODE: 5141 River Edge, NJ 07661

ADMINISTRATION OF FIRST AID POLICY

SAMPLE: Environmental Rounds and Safety Assessment Tool

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

First Aid in the Workplace Procedure

Fort Bend County Office of Emergency Management COMMUNITY PREPAREDNESS NEWSLETTER

EXPOSURE CONTROL PLAN

Section: TABLE OF CONTENTS Medical and First Aid. 03.A General B First Aid Kits C First Aid Stations and Health Clinics...

The 123 Assessment Businesses and Organizations

Southern Illinois Regional EMS System

specialising in maths and computing Health, Safety and Environmental Policy Date March 2012 Review Date March 2014 Governor Committee Health & Safety

Ch. 117 EMERGENCY SERVICES 28 CHAPTER 117. EMERGENCY SERVICES GENERAL PROVISIONS EMERGENCY SERVICES PLANNING ORGANIZATIONS

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

Emergency Medical Services Regulation. Adopted October 1, 2009

Office of Human Resources

1.2 The Trust Health and Safety Policy Statement (contained in the Trust Policy on Health and Safety) supports the delivery of this responsibility.

Township of Haverford Department Of Emergency Medical Services Report. March 2, 2015

Advanced Cardiac Life Support Provider & Provider Renewal Courses 2018 (ACLS & ACLS-R)

TITLE: EMERGENCY MEDICAL TECHNICIAN I CERTIFICATION EMS Policy No. 2310

Issuing Letters of Compliance (December 2016)

HEART SAFE SCHOOLS Project ADAM Wisconsin 1

New York State E-Plan Implementation Guide for County Local Emergency Planning Committees

~_/~ H wood T. Edvalson, MMC, City Clerk ~ -~ RESOLUTION NO. 2374

THE EVIDENCED BASED 2015 CPR GUIDELINES

Policy Checklist. To ensure the Trust acknowledges and accepts its responsibility under the Health and Safety (First Aid) Regulations (NI) 1982.

Chatham Emergency Squad Annual Report for 2015

Child Care Center Licensing Manual (August 2016)

First Aid Policy. Key document details. Health and Safety Manager. Author: Approver: Owner: H&S Department Version no.: 1.0

Preparedness Guide & Deployment Tips

OVERVIEW OF THE QUICK RESPONSE SERVICE

VIRGINIA ACTS OF ASSEMBLY RECONVENED SESSION

Procedure: First Aid in the Workplace

Emergency Procedures at the Workplace

Cardiac First Response Advanced Level. Education and Training Standard

Richmond School District Policy Statement Policy #: 453.1

Agency for Health Care Administration

Duties of a Principal

Components of the Emergency Action Plan

This order was adopted by the Board at its meeting on.

Revised December 2016 Volunteers Building Strong, Healthy, and Prepared Communities

MEDICAL SERVICES & FIRST AID PROGRAM

LOCAL SPORT DEFIBRILLATOR GRANT PROGRAM GUIDELINES OPENING: 1 NOVEMBER 2017 CLOSING: 20 DECEMBER 2017

Attachment B ORDINANCE NO. 14-

Certified Armed Protection Specialist (CAPS) Program. Instructors: BSIS approved instructors with firearms, baton, taser instructor certification.

Member Handbook September 16, 2014

Defibrillators for Sporting Clubs and Facilities Program : Round 5. Application Guidelines

Transcription:

Title: Automated External Defibrillator (AED) Policy Original Issuance Date: July 2017 Last Revision Date: N/A Author: Jesse Decker, Risk Management Officer POLICY PURPOSE The University of Wisconsin Platteville is committed to providing a safe and healthy environment for all staff, students and visitors. The purpose of the Automated External Defibrillator (AED) program is to increase the rate of survival of people who have sudden cardiac arrests by providing equipment. The goal of this policy is to: Implement enhanced life safety response measures Meet regulatory compliance Provide consistency across UW-Platteville in AED installation, maintenance and use Establish AED user training requirements SCOPE These guidelines are for UW-Platteville facilities with an AED Program and onsite AED trained personnel. Training criteria, continuing education, roles and responsibilities, standing orders, documentation, and quality assurance have been approved by the UW-Platteville Office of Risk Management and University Police. DEFINITIONS GOOD SAMARITAN LEGISLATURE: UW-Platteville workplace responders fall under the protection of the Cardiac Arrest Survival Act and state Good Samaritan legislation. Responding to a workplace medical emergency is purely voluntary. AUTHORIZED AED USERS AND TRAINING REQUIREMENTS Individuals approved to use AEDs shall have current training in CPR and AED. The training at a minimum should include adult CPR and AED and shall be based on the American Heart Association or American Red Cross. 1

POLICY STATEMENT UW PLATTEVILLE AED LOCATIONS 2 1 Art Building: Entry 22 Ottensman Hall: 3rd floor stockroom 2 Boebel Hall: 2 nd floor hallway 23 Pickard Hall: Main lobby 3 Bridgeway Commons: Entry 24 Pioneer Farm: Dairy housing facility entry 4 Bridgeway Stations: Checkout 25 Pioneer Student Center: Dining entrance 5 Brockert Hall: Main lobby 26 Pioneer Student Center: Help desk 6 Center for the Arts: lobby 27 Pioneer Tower: Main lobby 7 Children's Center* 28 Porter Hall: Main lobby 8 Cooper LLC: Main lobby 29 Royce Hall: Student health services 9 Dobson Hall: Main lobby 30 Russel Hall 1st floor hallway 10 Doudna: Main entrance 31 Southwest Hall: Main lobby 11 Doudna: Music study lounge 32 Ullrich: Main entrance 12 Engineering Hall: 1 st floor lobby 33 Ullsvik Hall: 2 nd floor elevator lobby 13 Engineering Hall: 2 nd floor entrance 34 Ullsvik: Admissions office 14 Gardner: LAE library hallway 35 University Police squad* 15 Greenway Avenue Market: Checkout 36 University Police SUV* 16 Hugunin Hall: Main lobby 37 Warner Hall: Main lobby 17 Library: Checkout desk 38 Wilgus Hall: Main lobby 18 McGregor Hall: Main lobby 39 Williams Fieldhouse: Pool 19 Melcher Hall: Main lobby 40 Williams Fieldhouse: East entry 20 Morrow Hall: Main lobby 41 Williams Fieldhouse: PAC desk 21 Ottensman Hall: 1st floor stairway 42 Williams Fieldhouse: Track control * Two sets of paddles (adult and pediatric) at Police Vehicles and Children s Center ITEMS THAT SHOULD BE PLACED WITH AEDs 2 pairs of non-latex gloves CPR barrier mask Scissors to easily remove clothing Disposable razor Cloth/towel/gauze EMERGENCY MEDICAL SERVICE NOTIFICATION Notification of the placement of a semiautomatic defibrillator must be made to the nearest emergency medical services program and must include the following: Type of semiautomatic defibrillator (manufacturer, make, model, etc.) Location of the defibrillator on the premises Intended usage area for the defibrillator Owner of the defibrillator For this reason, UW-Platteville has notified Southwest Health, City of Platteville Police Department, and City of Platteville Fire Department.

PROGRAM MANAGEMENT The AED program manager is responsible for scheduling and tracking ongoing training, ensuring equipment is properly maintained, tracking medical supplies, and all other documentation. The UW-Platteville Risk Management Officer is designated as the AED program manager. Responsibilities of the AED program manager: 1. Establish and document policies and procedures to ensure compliance. 2. Document and monitor compliance regulations and Good Samaritan requirements. 3. Be informed of federal, state and local legislation to track changes in laws and notifying all employees, especially the responder teams, of any changes. 4. Determine the number and location of AEDs within every facility. 5. Ensure that employees who may operate an AED are trained in CPR and AED. 6. Assist with coordinating or scheduling training for all trained responders and tracking certification expiration. 7. Post readily visible signs at appropriate building locations that specify AED location. 8. Maintain the equipment at each building where an AED is located; inspect all equipment and ensure it is in working order and replace supplies as needed. 9. Ensure event data is documented and evaluated in compliance with regulations following an incident. 10. Assign departmental maintenance funding in conjunction with Budget Office. VOLUNTEER AED RESPONDERS Responding to a workplace medical emergency is purely voluntary. Therefore, UW-Platteville staff who possess current CPR/AED training are in no way obligated nor required to respond to a sudden cardiac arrest or other workplace medical emergency. Each responder will receive instruction and maintain certification in CPR and receive appropriate training in the use of an AED presented by a certified American Heart Association/American Red Cross trainer. After initial training, each responder will receive refresher training every two years to review the response guidelines, use of the AED and receipt of current updates on protocols. Trained personnel may possess various amounts of training in emergency medical response and their training may be supplied by sources outside of UW-Platteville. Anyone wishing to potentially use one of the AED deployed should have successfully completed a state approved AED course including CPR within the last two years. Responder Duties Anyone can, at their discretion, provide assistance to victims of medical emergencies. The extent to which these individuals respond shall be appropriate to their training and experience. These responders are encouraged to contribute to emergency response on to the extent that they are comfortable. The emergency medical response to individuals may include CPR, AED or medical first aid. 3

Responder duties may include: 1. Retrieving the AED and accompanying emergency medical supplies 2. Providing prompt basic life support and first aid according to training and experience 3. Going to the site and assessing the victim 4. Beginning treatment that may include prepping the victim, CPR, and delivering a lifesaving shock 5. Documentation of incident reports 6. Maintaining certifications POST INCIDENT PROCEDURES Post Event Reporting and Review Following each deployment of an AED response, a review of the incident should be documented. The administrative unit responsible for the AED and the AED program manager will conduct and document the post event review and report. All key participants in the event will participate in the review. Included in the review shall be: 1. Administrative unit name 2. Date and time the AED was used 3. Location 4. Manufacturer, model number and serial number of AED used 5. Name of AED operator 6. Name of person on whom the AED was used 7. Brief description of circumstances under which the AED was used 8. EMS unit receiving the patient 9. Hospital the person was transported to, if known. 10. Name, email address, and telephone number of the person making the report If the incident involved an employee of UW-Platteville, a copy of the completed AED incident report will be submitted to the worker s compensation coordinator following the incident. An additional copy of the AED incident report will be submitted to the UW System s Director of Risk Management within five days after the incident occurred. A copy of the UW-Platteville AED incident report will be kept on file with the AED program manager. Documentation The AED program manager will do the following after any AED use: 1. Notify appropriate University Police and City of Platteville Response Units. 2. Complete an incident report 3. Maintain a copy of the incident report 4. Document all equipment serviced, inspected, and maintained Restocking Equipment and Supplies 1. Return the AED to a state of readiness 2. Replace used defibrillator pads, batteries, razors, gloves. Inspect all supplies for any damage, expiration dates, and required replacement 3. Inspect the exterior and connector for dirt or contamination. 4

EQUIPMENT AND SUPPLIES With the goal of putting UW-Platteville in a position of readiness, responders should have equipment and supplies available to treat the highest percentage of emergencies possible. The AED and other equipment and supplies shall be located and readily accessible so responders do not have to search for them. TRAINING REQUIREMENTS Individuals approved to use AEDs shall be trained in CPR and AED usage. The training should be based on the American Heart Association or American Red Cross and taught by an authorized instructor. Courses at a minimum must include adult CPR and AED. These individuals must remain current with their certifications. MAINTAINING EQUIPMENT AND SUPPLIES All equipment and supplies, including AEDs must be serviced, inspected and maintained so that it is in constant state of readiness. Though AEDs are self-servicing in many ways, the adhesive on their pads and their batteries have limited life spans. The AED program manager is responsible for having regular equipment maintenance performed. All maintenance tasks shall be performed according to equipment maintenance procedures as outlined in the operating instructions. After every incident, trained personnel shall service all supplies and equipment. The program manager shall ensure the re-supplying of emergency medical response equipment. Expiration dates on all supplies and equipment must be tracked and maintenance records kept. Document all equipment serviced, inspected, and maintained. Consistent maintenance ensures equipment will be ready in an emergency. SYSTEM VERIFICATION AND SUPPLIES An AED response is ultimately successful if necessary medical assistance is provided to victims in a timely manner. Since actual use of this system procedure is expected to be very infrequent, other measures of effectiveness are required. Periodic Testing of AEDs The AED program manager or designee(s) will conduct periodic checks on the AEDs. These checks shall include review of the following elements: Emergency kit supplies AED battery life AED operation and status Other AED Equipment readiness DOCUMENTATION AND RECORDKEEPING Maintaining both an AED program and the ability to effectively respond to a sudden cardiac arrest is an ongoing process that will need to be reviewed and updated on a regular basis. 5

Consistent documentation and record keeping provides data required to accomplish this. From a legal standpoint, documentation and record keeping are necessary to ensure that regulatory guidelines have been met. Recording training, protocols, equipment maintenance and emergency response outcomes helps to monitor policies, procedures and training for consistency. By tracking this information, it is easier to schedule workplace responder coverage; account for vacations, retirements and job changes; know when new responders need to be recruited and trained; and ensure that trained responders maintain their certifications. Important documentation in an AED program includes: 1. Locations of all AEDs and equipment 2. Who has been trained, when they were trained, type of training (i.e., AED, CPR, Bloodborne Pathogens) and who conducted the training 3. Training card expiration dates 4. Dates of training re-certifications 5. Dates of practice drills (voluntary) 6. Communications to employees on the emergency notification and response procedures 7. Maintenance logs of equipment and supplies 8. Incident log with outcomes RELATED DOCUMENTS STATE OF WISCONSIN AED REGULATIONS 2007 Wisconsin Act 104 (Senate Bill 142) Senate Bill 142 requires many occupations within Wisconsin to successfully complete cardiopulmonary resuscitation (CPR) training, and to demonstrate current proficiency in the use of an automatic external defibrillator (AED). This requirement applies to employees of day care centers, shelter care facilities, residential care facilities, medical transport drivers, fitness centers, lifeguards and many others. This policy provides procedures for the selection, placement, purchase and maintenance of AEDs in all University facilities and vehicles. The use of an AED is one step in the process of improving survival rates for victims of sudden cardiac arrest. According to the American Red Cross, each year in the United States over 250,000 people die of sudden cardiac arrest before reaching a hospital. A person s chance of survival can be increased by establishing a Chain of Survival system that includes early recognition (calling 911), early cardiopulmonary resuscitation (CPR), early defibrillation, and access to advanced cardiac life support by emergency medical services (EMS) and medical facilities. 2009 Wisconsin Assembly Bill 725 Beginning in the 2010 11 school year, each school board operating high school grades, the operator of each charter school established under s. 118.40 (2r) that operates high school grades, and the governing body of each private school that operates high school grades shall offer instruction in cardiopulmonary resuscitation, cardiocerebral resuscitation, and the use of an AED to pupils enrolled in the high school grades in the school district, charter school, or private school. 6

2008 Wisconsin Statues Chapter 146 Wisconsin Statutes, Section 50.36(5) Instructions and Proficiency in the Use of AED (April 24, 2009), Wisconsin Department of Health Services. Wisconsin Statutes Chapter 146 AED owners must provide written notification to the EMS program and make sure that the AED is maintained and tested according to the manufacturer s guidelines. Prospective AED users must complete a training course approved by the Department of Health and Family Services. An ACT to create 118.076 of the statutes; relating to providing instruction in cardiopulmonary resuscitation, cardiocerebral resuscitation, and the use of an automated external defibrillator to high school pupils. This bill requires operators of high school grades, including school boards, operators of independent charter schools, and the governing bodies of private schools, to offer enrolled high school students instruction in cardiopulmonary and cardiocerebral resuscitation and the use of an AED. The instruction must be based on an instructional program established by the American Red Cross or the American Heart Association. 2006 Wisconsin Senate Bill 186 Senate Bill 186 extends immunity protection for users, owners, and providers of AEDs for acts or omissions in rendering emergency care in good faith. 2000 Wisconsin Assembly Bill 521 Redefines the term first responder, and establishes criteria for the certification and recertification of first responders. 1999 Wisconsin Assembly Bill 239 Provides immunity protection and establishes guidelines for AED use. Requirements: o EMS Notification A person who provides an automatic defibrillator or a semiautomatic defibrillator shall provide written notification to the nearest emergency medical services program. o Maintenance Program Must ensure that the automatic defibrillator or semiautomatic defibrillator is maintained and tested in accordance with any operational guidelines of the manufacturer. Good Samaritan Protection Rescuer, Purchaser, Property Owner, Trainer The person who in good faith renders emergency care by use of an AED to an individual who appears to be in cardiac arrest is immune from civil liability for the acts or omissions resulting from the use of the AED as long as the act or omission does not constitute gross negligence. The owner of the AED is immune from civil liability for the acts or omissions of a person rendering emergency care by use of an AED as long as the act or omission does not constitute gross negligence. 7

Any person who provides training in the use of an AED to the person who renders care is immune from civil liability for the acts or omissions of the person rendering emergency care as long as the act or omission does not constitute gross negligence. The person who provides the AED for use is immune from civil liability for the acts or omissions of a person who in good faith renders emergency care by use of an AED to an individual who appears to be in cardiac arrest, if the person who provides the AED ensures that the AED is maintained and tested in accordance with any operational guidelines of the manufacturer and if the act or omission resulting from the use or provision for use of the AED does not constitutes gross negligence. POLICY HISTORY The initial approval for this policy is July 2017. SCHEDULED REVIEW Annual Inspection Once each calendar year, the AED program manager shall conduct an annual inspection and review the AED s and AED program. This review shall include review of the following elements: Training records Equipment operation and maintenance records 8