EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

Similar documents
1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

Declaration of Classification ValiSpore Incubator Manual

Personal Health Monitoring Services SM VITAL SIGNS TRANSMITTER MODEL: VST 3 TM. Instruction Manual

Setting a new standard for performance, safety and simplicity

Operating Manual for HEKA Incubators

TARGUS NOTEBOOK SECURITY DEFCON SCL SERIALIZED COMBINATION CABLE LOCK

Our Terms of Use and other areas of our Sites provide guidelines ("Guidelines") and rules and regulations ("Rules") in connection with OUEBB.

Pressure IQ Evolve Mattress Replacement System USER MANUAL

Feel at home. No matter where you stay. TECHNICAL MANUAL

Proposal for the Suicide Bomb Detector Model # RDS400

Medical Grade Power Strips

LF1090 BARIATRIc. USeR MANUAL. LF1090-INS-LAB-RevD GF Health Products, Inc.

DEFCON KL. Notebook Computer Key Lock

Blue Jeans Go Green UltraTouch Denim Insulation Grant Program OFFICIAL GRANT APPLICATION GUIDELINES

Key to BEDSIDE External Pulse Generator Controls and Features

DEFCON Authenticator. with Dual USB Port Hub

INTRODUCTION. AUTHORIzATION A Word of Caution

User-Service Manual Joerns Assist Handle Model F025

Product Introduction. Specification Sheet. Certificates. Application. Features. Street Light

Request for Proposal Hydraulic Rescue Tools. Date Issued: September 28 th, 2016

Isolette TI500 Neonatal Transport

2018 NEW HAMPSHIRE ELECTRIC COOPERATIVE (NHEC) COMMERCIAL WEATHERIZATION PROGRAM

ARMY TB

Oak Grove School District Respiratory Protection Program

LF1090 BARIATRIC PATIENT LIFT

SPECIAL SPECIFICATION 1849 ATM Switch Single-Mode OC-12 Module

RESPIRATORY PROTECTION PROGRAM

250- PERSONAL PROTECTIVE EQUIPMENT PROGRAM

VFD and Pump Incentive Application for Business Customers

TESTING APPLICATION STANDARD (TAS) IMPACT TEST PROCEDURES

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

TranSync Compliance Monitoring Manual. Homecare Provider/Authorized Monitors

Lodestar. Series. Specification Sheet. Application. Features. Floodlight. Tunnel Lighting. Parking Applications. Canopy Lighting Wash Lighting.

Carter Healthcare, Inc

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1041 ASPHALT CONCRETE QUALITY ASSURANCE PROGRAM ADMINISTRATION.

JERSEY COLLEGE RECOGNITION OF 5000 TH GRADUATE SCHOLARSHIP PROGRAM RULES FOR PARTICIPATION AND AWARDING

Medical furniture OPTIMA OBSTETRIC BED

Redevelopment Authority of Allegheny County

BUSINESS. New Construction. Save money on qualified construction projects. Read about rebates for your home and business at mid.

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

REVEAL. Patient Assistant 9538/9539. Clinician Manual. Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician.

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

Ceremonial Bugle Operation Manual and Military Funeral Honors Guide

Laboratory Accreditation Program CRITERIA

User Manual for Spirit Beds

STANDARDS Point-of-Care Testing

Specifications, Performance & Submittal

Buck & Boost Transformer Installation Instructions

Approved for public release. Distribution is unlimited.

DEPARTMENT OF THE ARMY SUPPLY BULLETIN

Automated License Plate Reader (ALPR) System. City of Coquitlam. Request for Proposals RFP No Issue Date: January 25, 2017

City of Jacksonville, Alabama Public Square Overlay District. Façade Improvement Program APPLICATION AND AGREEMENT

National Fenestration Rating Council. Incorporated. NFRC CAP-2007 Certification Agency Program 2007 NATIONAL FENESTRATION RATING COUNCIL, INC.

TECHNICAL MANUAL OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

MCC. SMBJP6KE6.8(C)A THRU SMBJP6KE550(C)A. Features. Transient Voltage Suppressor 6.8 to 550 Volts 600 Watt.

Simply Intuitive. The Hill-Rom Advanta 2 Bed

Position within the Organisation GP Research Lead

Administrative Policies and Procedures. Policy No.: N/A Title: Medical Equipment Management Plan

Redefining Patient Handling. prevention

SERVICE BULLETIN TRANSMITTAL SHEET HC-SB Blade - Secondary Windings on ( )7690 and ( )7890 Composite Blades

201 North Forest Avenue Independence, Missouri (816) [September 25, 2017] REQUEST FOR PROPOSAL GRADUATION CAPS AND GOWNS

The RYOBI COMMIT2IT Contest. Official Rules

1 Customer and Contact Information

Redefining Patient Handling. prevention

Compounded Sterile Preparations Pharmacy Content Outline May 2018

Laboratory Risk Assessment: IQCP and Beyond. Ron S. Quicho, MS Associate Project Director Standards and Survey Methods, Laboratory July 18, 2017

SURGICAL SERVICE SPECIALTY. Set Up and Safe Operation of Equipment

Authorized licensed use limited to: UNIVERSITA MODENA. Downloaded on November 10,2011 at 14:46:47 UTC from IEEE Xplore. Restrictions apply.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

SARASOTA MEMORIAL HOSPITAL

SUNY ONEONTA RESPIRATORY PROTECTION PROGRAM

M-COR Modular Hip System Surgical Technique Chart

Request for Proposal. Purchase of New Mobile Trailer Climbing Wall. No November 23, 2015

Academy Sports Football Scholarship Program Rules SPONSOR: ACADEMY SPORTS

A. General provisions and other electrical systems are specified in other Sections of Division 26.

Energy Efficiency Alberta Residential and Commercial Solar Program Guidebook

3M Sterilization Assurance Standards Practice. In Sterilization with the Core Four

City of Hays Request for Proposal. Wastewater Treatment Plant Fiber Connectivity

Enterprise On-Demand Attachment Last Revised 8/6/ Enterprise On-Demand

REQUEST FOR PROPOSALS FOR REPLACEMENT OF GENERATOR AT LAKE HILLS 1860 BOOSTER PUMP STATION

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE 2A & 2B Raja S.C.Mullick Road Jadavpur, Kolkata

NRC INSPECTION MANUAL

2.3. Any amendment to the present "Terms and Conditions" will only be valid if approved, in writing, by the Agency.

City of Gainesville State of Georgia

Energy Efficiency Alberta Residential and Commercial Solar Program Terms and Conditions

GREAT RIVER GIVES BACK DONATION PROGRAM

Abu Dhabi Occupational Safety and Health System Framework (OSHAD-SF) Code of Practice

VISITING SCIENTIST AGREEMENT. Between NORTH CAROLINA STATE UNIVERSITY. And

SERVICE BULLETIN TRANSMITTAL SHEET HC-SB Governor - Speeder Compression Spring

University of North Dakota Facilities Department Respiratory Protection Program. Table of Contents. 1.0 Introduction Purpose...

CMS REQUIREMENTS: ESSENTIAL ELEMENTS FOR ASCS

Letters.org. SCHOLARSHIP RECOMMENDATION LETTER. Included: Scholarship Recommendation letter

Organization for Economic Co-operation and Development

SmartStart Buildings Program Performance Lighting Application FY18 July 1, 2017 June 30, 2018

Health and Safety at Work (General Risk and Workplace Management) Regulations 2016 (LI 2016/13)

Quality Management Training for Blood Transfusion Services

EasyCare Maximizing Care, Comfort and Safety

Notre Dame College Website Terms of Use

Efficient Use of Valuable Space

Transcription:

EZTest Incubator OPERATION MANUAL 10 Evergreen Drive Bozeman, MT 59715 USA (303) 987-8000 www.mesalabs.com 16 1

This page intentionally blank. 2 15

This page intentionally blank. Table of Contents Introduction 3 Safety Information 4 Installation & Warm Up 5 Temperature Selection 6 Operation 7 Maintenance & Service 9 Warranty 11 Specifications 12 Introduction The Mesa Labs biological indicator incubator is designed for convenient and effective incubation of self contained biological indicators requiring incubation temperatures of 37 C, 57 C, or 60 C. The incubator features a built in thermometer with LED display, 13 incubation cavities, and an integrated activation (crushing) cavity. A self contained biological indicator consists of a capped thermoplastic culturing vial containing a glass media ampoule and a carrier inoculated with bacterial spores. Upon removal from the sterilizer, the indicator is activated by flexing the plastic culturing vial to crush the inner glass ampoule which allows the growth medium to contact the spore carrier. The activated indicator is then incubated for a specified length of time and observed for color change of the growth medium. If the medium turns yellow during incubation, the test is positive indicating growth and inadequate sterilization. 14 3

Safety Information This page intentionally blank. Handle with caution. The surface of the incubator may become hot to the touch. The incubator has been designed with function, reliability, and safety in mind. It is the user s responsibility to install it in conformance with local electrical codes. For safe operation, please pay attention to the alert boxes throughout the manual. Warning! Caution Note Refer to manual. Cautions alert you to potential equipment damage and hazards. Notes alert you to pertinent facts and conditions. Use Only as Directed Indoor use only. Temperature 10 C to 35 C. Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 35 C. Main power supply voltage fluctuations not to exceed ±10% of the nominal voltage. Installation class II service. Polution Degree 2 environments. Altitude less than 2000m. 4 13

Specifications Incubator Catalog Number I1410 Overall Dimensions Width 3.5 in / 9 cm Height Depth Weight 2.0 in / 5.08 cm 4.0 in / 10.2 cm 0.89 lb / 0.4 kg Incubation Cavities Number 13 Diameter Depth.375 in /.94 cm 1 in / 2.54 cm Thermometer Accuracy + / 1ºC Electrical Ratings (for use with certified class 2 power supply) Volts 12VDC Watts 18.0 Amps 1500 ma Operating Range Temperature 37ºC / 57ºC / 60ºC Environmental Conditions Conformance Power Supply Ambient Temperature 10ºC 35ºC Relative Humidity 20% 80% Non condensing CSA/C/US, CE, RoHS, FCC Part 15 Class A, ICES 003 Class A Catalog Number P6 1000 Rated Input Voltage Input Voltage Range Rated Frequency 100 240VAC 90 264VAC 50 60Hz Rated Input Current 1.0A Output Voltage 12VDC Max Output Current 2.5A Max Output Wattage Safety Approvals EMC/EMI RoHS Compliant 30W UL/cUL, GS, CCC, RCM FCC class B, CE, VCC I class II Storage Temperature 10 C 70 C Storage Humidity 10 90% Operating Temperature 0 40 C Operating Relative Humidity 20 80% Yes Installation and Warm Up The incubator is designed for continuous operation and does not have a power switch. The incubator will power on when it is plugged into a power source. Note: the incubator must be installed in a location where temperature is maintained between 10 C (50 F) and 35 C (95 F). 1. Remove the incubator from its packaging. 2. Unpack the power supply. The power supply includes four interchangeable blades (plugs). Select the appropriate blades for your region and attach the blades to the power supply. 3. Plug the power supply into a power source. 4. Insert the small connector from the power supply into the matching receptical in the back of the incubator (see Figure 1). 5. The incubator will automatically power on and perform a selftest. Upon completion, the installed firmware revision will be displayed on the LED screen for two seconds. 6. The incubator will begin its warm up phase. During this time the configured temperature setpoint will fade in and out on the LED screen. 7. The incubator is ready to use when the configured setpoint is no longer fading in and out, and the LED screen displays the current operating temperature of the incubator. Note: it may take approximately 15 minutes for the incubator to warm up to operating temperature, depending on the selected incubation temperature and the temperature of the environment in which the incubator is installed. 12 5

Temperature Selection The incubator can be configured to operate at 37 C for biological indicators containing Bacillus atrophaeus, or 57 C or 60 C for biological indicators containing Geobacillus stearothermophilus. The incubator is initially configured to operate at 60 C. Caution: failure to set the correct incubation temperature will yield invalid test results. It is not possible to incubate at multiple temperatures simultaneously. Refer to the instructions for use for your biological indicators to select the appropriate incubation temperature. 1. With the incubator powered on, simultaneously press and hold the two small buttons on the rear of the incubator (see Figure 1) for ~2 seconds until the currently selected temperature setpoint blinks on the LED display. 2. Release the buttons, then press either button repeatedly to toggle between the available temperature setpoints (37 C, 57 C, or 60 C). 3. When the desired temperature setpoint is blinking on the display, press and hold both buttons for ~2 seconds. 4. The configured setpoint will fade in and out on the LED screen until the incubator has reached temperature, upon which the actual temperature of the incubator will be displayed. Figure 1 Rear of Incubator Warranty Mesa Labs expressly warrants the biological indicator incubator manufactured by it as set forth herein. Mesa Labs makes no other warranties, either express or implied. No warranty as to merchantability or fitness for a particular purpose shall apply. In addition, the following shall constitute the exclusive remedies of buyer for any breach by Mesa Labs of its warranty hereunder. Material and Workmanship: Mesa Labs warrants the incubator manufactured by Mesa Labs shall be free from defects in material and workmanship, under normal use and service, for a period of fifteen (15) months from the date the product shipped from Mesa Labs. If any part of the equipment is returned within this time and found by Mesa Labs to be defective in workmanship or material, it will be replaced or repaired, free of charge and returned F.O.B. your plant. Any equipment or part thereof so replaced or repaired shall be warranted by Mesa Labs for the remainder of the original warranty period. All replacements or repairs necessitated by inadequate preventive maintenance, or by normal wear and usage, or deterioration under unsuitable environmental conditions shall be at Buyer's expense. Buyer may incur service charge for evaluation of returned equipment not found to be defective. Mesa Labs shall not be obligated to pay any charges incurred by Buyer except as may be agreed upon in writing in advance by Mesa Labs. Limitation of Remedy: Mesa Labs shall not be liable for damages caused by delay in performance. The sole and exclusive remedy for breach of contract shall be limited to repair or replacement under the standard warranty clause. In no case shall Mesa Labs liability exceed the price to buyer of the specific goods manufactured by Mesa Labs giving rise to the cause of action. Buyer agrees that in no event shall Mesa Labs liability extend to include incidental or consequential damages. 6 11

Service The incubator is not field servicable. In the event of an incubator malfunction, please contact your dealer immediately. When requesting service, please have ready the model and serial number of the incubator. The model and serial number are located on the bottom of the unit. Prior to returning any materials, a Return Goods Authorization (RGA) must be obtained from your dealer. Any materials returned without an RGA will be refused. Operation Note: refer to the instructions for use supplied with your biological indicators for information on processing, incubation, interpretation of results, and using positive controls. When the incubator has reached the configured temperature, the actual temperature of the incubator will be shown on the LED display, indicating that the unit is ready to accept biological indicators. Verify that the temperature displayed is within the allowable range for your biological indicator before proceeding (see the instructions for use supplied with your biological indicators). Biological Indicator Activation Prior to incubation, the biological indicator must be activated by crushing its internal glass medium ampoule. This allows the colorchange medium from the ampoule to contact the spore carrier.! WARNING: allow a processed BI to cool for at least 10 minutes upon removal from the sterilizer. Failure to do so may cause the glass medium ampoule to burst during activation, resulting in injury from hot liquid or flying debris. The incubator contains an activation (crushing) cavity to simplify activation (see Figure 2). Place the processed or positive control biological indicator into the left side of the activation cavity and flex the indicator to the right until the glass ampoule breaks. Note: you may have to grip the incubator by the base while activating a BI so that it does not tip over. Incubation To confirm adequate sterilization (negative result), self contained biological indicators must be incubated for the appropriate length of time ( incubation time ). Please refer to the instructions for use that came with your biological indicators for the proper incubation time. 10 7

Immediately upon activation, place the indicator into one of the thirteen numbered incubation cavities (see Figure 2). Record the incubation start time and cavity number. Observe the color of the growth medium in the BI at regular intervals during incubation. A color change to yellow during the incubation time indicates bacterial growth (positive test). If the incubation time expires and no color change to yellow is observed, this indicates a negative test. Caution: if a positive control does not grow, do not use the remaining units from the box and contact your dealer immediately. A positive control that does not turn yellow is a serious problem. Fortunately, the causes are few: a grossly malfunctioning incubator, inadvertent sterilization of the control vial, inadvertent sterilization of the box of indicators, or improper storage. If the control is negative because of one of the latter two causes, do not use any of the other biological indicators from the same box. Dispose of positive or negative BIs immediately per the instructions for use that accompany each box of indicators, or per your organization s policy. Figure 2 Top of Incubator Maintenance & Service The incubator requires no maintenance other than cleaning as necessary. Cleaning 1. Unplug the incubator before cleaning. 2. To clean the exterior, use a cloth dampened with isopropyl alcohol. 3. To clean the incubation and activation cavities, use a cotton swab dampened with isopropyl alcohol.! WARNING: DO NOT IMMERSE THE UNIT IN ANY LIQUID AND DO NOT SPRAY OR POUR LIQUID DIRECTLY ONTO THE UNIT. DOING SO MAY DAMAGE THE INCUBATOR AND VOID YOUR WARRANTY. Replacement Parts Description Quantity Required Part Number Power Supply 1 P6 1000 Temperature Verification The incubator, including the LED temperature display, is factory calibrated using a NIST traceable temperature standard and does not require user calibration. Incubation temperature can be verified by placing an NIST traceable thermometer into one of the incubation cavities and allowing 30 minutes for temperature stabilization. The temperature reading should be within +/ 2 C of the incubator set point temperature. 8 9