AQUATIC HEALTH PROGRAM PLAN REVIEW SUBMISSION INSTRUCTIONS FOR MINOR REMODEL

Similar documents
FATS, OILS, & GREASE (F.O.G.) SPECIFICATIONS & DETAILS

Apprenticeship Curriculum Standard. Pool & Spa Hot Tub Installer. Level 2. Trade Code: 237T

2015 C&I PROCESS VFD APPLICATION FOR PRESCRIPTIVE REBATES

Environmental Standard Operating Procedure

VFD and Pump Incentive Application for Business Customers

WATER QUALITY MANAGEMENT PERMIT

1 Customer and Contact Information

2017 SOUTHEAST DESIGN AWARDS

ReWa Capacity Approval Process Public Main Extension Project

Regulatory Services Division Industrial Discharge Control Section

City of Provo, Utah Parks and Recreation Department. Request for Proposal (RFP) Architectural Services for a New Community Recreation Center

815 KAR 20:191. Minimum fixture requirements.

A Guide to. Starting a Business. Auburn, GA

Local Weatherization Guide

Belmar Business Partnership Inc.

Approved for public release. Distribution is unlimited.

LICENSING GUIDE FOR OPERATORS OF WASTEWATER FACILITIES. Licensing of Sewage Works Operators, O. Reg. 129/04

EXISTING CONDITIONS

CITY OF KYLE, TEXAS REQUESTS FOR PROPOSAL (RFP) RESURFACING OF CITY OF KYLE POOL AND SPA: RFP PARD

2016 Energy Efficiency Program Annual Report

16.01 FACILITIES SERVICES POLICY Cabinet Approval: 09/25/03 CHAPTER 2 Board of Trustees Approval: 10/08/03 POLICY 16.01

WarmWise Business Custom Rebates Program Manual

COMMERCIAL BUSINESS LICENSE REQUIREMENTS REQUIREMENTS FOR COMMERCIAL BUSNIESS. Fee

INSTRUMENTATION TECHNICIAN I/II/III

Ground Source Heat Pump - July 1, 2016 through June 30, 2017

Smart Energy New Homes Program

STATE OF ALASKA COMPETENCY SPECIFICATION

ADMINISTRATIVE VARIANCE APPLICATION PACKET

Play house - $30 (Westminster)

Revision #: 0 Prepared By: Beth Eckert, Industrial Chemist Revision Date: 1/10/00 Approved By: Larry Cummings, Asst. Superintendent of WWTD

B. All of the documents in this RFP form the Basis-of-Design for this project.

2015 REMODELING AWARD OF EXCELLENCE PROGRAM

City of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR

INSTITUTIONS REGULATION, 1981

ERASE REDEVELOPMENT GRANT

LAURENS COUNTY PARKS, RECREATION AND TOURISM. Accommodations Tax Grant Application

Northern Sonoma County Air Pollution Control District Burn Clean! Wood Appliance Replacement Program

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION DISTRICT II EXHIBIT D DISTRICT TWO BRIDGE TENDER QUALIFICATIONS MANUAL

2018 NEW HAMPSHIRE ELECTRIC COOPERATIVE (NHEC) COMMERCIAL WEATHERIZATION PROGRAM

1.5 to 5 Tons INDOOR COILS C33. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

REQUEST FOR PROPOSALS FOR REPLACEMENT OF GENERATOR AT LAKE HILLS 1860 BOOSTER PUMP STATION

HOME RENOVATION TAX CREDIT (HRTC)

REQUEST FOR QUALIFICATIONS PROFESSIONAL ENGINEERING SERVICES for CITY OF SHELBY, NORTH CAROLINA. Shelby Water Treatment Plant Plant Upgrades

Food Service and Pool Sanitation

Small Business Assistance Program Guidelines

CITY OF PITTSFIELD SPECIAL EVENT CHECKLIST & APPLICATION PACKET

Glenview School District Greenwood Rd Glenview IL Request for Qualifications For Architect Services

CHAPTER 08 - ENGINEERING AND BUILDING CODES DIVISION SECTION GENERAL PROVISIONS SECTION NORTH CAROLINA STATE BUILDING CODE

PPL s Business Energy Efficiency Program Direct Discount for Small Commercial & Industrial

Facilities Services Division

Nonprofit Facility Grant Program

Arizona Department of Health Services Rules. Nursing Care Institution Administrators

RULE DEFINITIONS RULE WATER CONSERVATION REBATES A. QUALIFYING DEVICES

#Creating a Career in Cleaning. Your Career Your Goals Our Training

Effective Date: September, 2007 Revision Date: May 9, FASA Handbook - Chapter 4 MEDICATION

Subdivision Presubmittal Conference Submittal Package Cover Page

Smart Energy New Homes Program

EPISCOPAL CHURCH OF OUR SAVIOUR REQUEST FOR PROPOSAL FOR JANITORIAL AND CLEANING SERVICES FOR CHURCH SANTUARY, CHURCH OFFICE AND UNDERCROFT

CITY OF MADISON HEIGHTS OFFICE OF THE CITY CLERK BUSINESS LICENSE INITIAL APPLICATION

Belmar Business Partnership, Inc. Business Development Committee

SECTION I Applicant/Project Information

Montgomery Housing Authority 525 South Lawrence Street Montgomery, Alabama 36104

SUNY ONEONTA RESPIRATORY PROTECTION PROGRAM

ADDENDUM NO. 1 CITY OF FREDERICK PURCHASING DEPARTMENT 111 Airport Drive East Frederick, MD (301)

Special Operations - Aerospace Pararescue and Recovery Facility (Guardian Angel Rescue Squadron [RQS]). FAC: 1444

Con Edison Commercial and Industrial Energy Efficiency Program

CHEMICAL HYGIENE PLAN

DRAFT. (Industry Name) (Industry Address) (Industry Address) (SIC NUMBER (S))

Request for Qualifications to Certify Qualified Providers for the Arkansas Energy Performance Contracting Program

LCB File No. T015-98

SEPTIC MAINTENANCE PROGRAM RULES (ARTICLE 10)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

RESTAURANT GRANT PROGRAM

7700 East First Place Denver, CO ph (303) fax (303)

REQUEST FOR PROPOSALS FOR COMMERICAL GENERATOR MAINTENANCE & REPAIR. Released February 3, 2017 Submissions Due February 28, 2017

Submission, Review, and Approval Procedures

REQUEST FOR PROPOSALS FOR PROFESSIONAL SERVICES

SmartStart Buildings Program Performance Lighting Application FY18 July 1, 2017 June 30, 2018

Pedernales Electric Cooperative. Comprehensive Commercial Rebate Program Manual

Ensure that the application is legible; please print in ink or type information onto form.

TRINIDAD AND TOBAGO BUREAU OF STANDARDS

MONTGOMERY COUNTY HEALTH DEPARTMENT

QRO Operator Certification Renewal Application

Approved for public release. Distribution is unlimited.

SOUTH HEIDELBERG TOWNSHIP - SUNOCO MARINER EAST II PIPELINE TALKING POINTS

Renewable Energy Bonus Scheme - solar hot water rebate. Guidelines and application form

Queensland Government Solar Hot Water Rebate Guideline and Application

Applicant Information Booklet

Request for Qualifications Fundraising Consultant

Outstanding Civil Engineering Achievement Award

Marlboro County School District

Incident Reporting, Notification, and Review Procedure

Design Build Services Lake Shawnee Junior Pond Improvements

FACILITIES MANAGEMENT

Incubator Policy and Procedures

POSITION DESCRIPTION

Request for Proposal. WEBSITE DESIGN and CONTENT MANAGEMENT SERVICES

LIVESMART BC: EFFICIENCY INCENTIVE PROGRAM TERMS AND CONDITIONS EFFECTIVE APRIL 1, 2013

ELECTRICAL INSPECTION ACT CANADIAN ELECTRICAL CODE REGULATIONS

Charter The Charter of the County of Suffolk. Commissioner The Commissioner of the Suffolk County Department of Health Services.

Transcription:

l AQUATIC HEALTH PROGRAM PLAN REVIEW SUBMISSION INSTRUCTIONS FOR MINOR REMODEL Nevada State Law, NRS 444.080, requires that properly prepared plans and specification be submitted to the Health Authority for review and approval when construction or remodeling of a public pool, spa, bathhouse or nudist colony is anticipated, prior to the start of such work. 1. Application Submittal/Appointments: Direct Line: (702) 759-0571 Email: aquatichealth@snhdmail.org Applications for minor remodel may be submitted in person or via email. For applications submitted in person, an appointment must be made prior to plan submission. For applications submitted via email, an appointment must be made if the plan review inspector determines that one is necessary. Appointments cannot be honored unless the minimum required paperwork has been submitted and all required fees have been paid. Failure to provide the minimum documentation upon arrival for an appointment constitutes a MISSED APPOINTMENT, and a fee will be assessed. As an option, an applicant may pay for a preliminary (office) plan review and meeting with staff, but this does not constitute a formal Plan Submission. THE MINIMUM REQUIREMENTS FOR AN APPOINTMENT: a. A representative qualified to answer staff questions and empowered to make corrections, additions, or deletions at the meeting. b. A signed copy of this Plan Review Submission Instructions for Minor Remodel sheet. c. A Plan Review Minor Remodel Worksheet signed by a professional engineer or architect registered in the State of Nevada, or by a licensed contractor who holds a classification A license with an A-10 subclassification issued by the State Contractor s Board. d. A copy of the Certification of Contracted Services sheet signed by the legal owner of the establishment or the owner s representative. e. Any required equipment specification sheets as outlined on the Plan Review Minor Remodel Worksheet. f. Ability to pay all applicable fees (Cash, Visa/MasterCard [credit card and valid I.D. must match exactly] or Business Check [pre-printed address, no started checks, no alterations]) Revised 2/23/2015 jh Page 1 of 8

2. Fees: A plan review application must be made and all applicable fees paid at the time of appointment and plan submission. If applications are submitted via email, all required fees must be paid in full at the time of plan submission. Plan review fees are only valid for one year from the date of the original submission. 3. Approval of Plans: Payment of fees does not constitute approval of plans. A signed voucher will be provided following your meeting to inform you of the approval status of your plans, to provide specific corrections and/or stipulations, to list any permit conditions or limitations, and to request any additional information needed to complete your application. If the application is submitted via email, the plan review inspector will email or fax a signed voucher to inform you of the approval status of your plans, to provide specific corrections and/or stipulations, to list any permit conditions or limitations, and to request any additional information needed to complete your application. If the plan review inspector deems necessary, a meeting may be required prior to plan approval. The inspector will contact you to schedule the meeting. Applicants may be required to submit corrected plans. Failure to comply with required corrections may result in a failed inspection of the remodel project, resulting in additional fees and delayed approval to open. 4. Once Work Begins: After approval has been granted to begin remodel work, the body of water must remain closed from the start of work until the final inspection has been performed and remodel work has been approved. 5. Final Inspection: A final field inspection is required on all remodels. Arrangements for final inspections must be made at least 72 hours (three business days) in advance of the final inspections. There will be a re-inspection fee for each permit if the establishment is not ready for a final inspection after you have requested one. The body of water must pass a complete operational inspection at the time of the final inspection. Cancellations must be made prior to staff arrival at the facility or a re-inspection fee will be assessed. The re-inspection fee must be paid prior to scheduling another final inspection. Revised 2/23/2015 jh Page 2 of 8

6. Inspection Appointments: Appointments will be on a first-come, first-served basis and will depend on the assigned inspector workloads. After hours inspections may be offered, at the discretion and availability of the assigned staff member and a fee will be assessed for this service. 7. Revised Plans: After plans have been reviewed and approved, if it becomes necessary or you wish to submit revised plans, contact your assigned Plan Reviewer. Each submittal of revised plans will be charged an additional fee. 8. Mistakes or Omissions: Plan approval does not constitute approval of any mistake or omission. Proper development of a project is the responsibility of the contractor, engineer, architect and/or the various parties concerned. I have been made aware of the regulatory requirements and I understand the proper development of this project is my responsibility: (initial) Name, Print: Signature: Title: Company: Date: Name of Facility: Revised 2/23/2015 jh Page 3 of 8

DATE RECEIVED: (FOR OFFICE USE ONLY) POOL SPA (FOR OFFICE USE ONLY) FACILITY ID: PR#: SR#: PLAN REVIEW MINOR REMODEL WORKSHEET TYPE OF APPLICATION (CHECK ALL THAT APPLY) INDOOR OUTDOOR POOL/SPA WITH LIVING UNITS YES NO PARTY POOL YES NO BODY OF WATER TYPE SWIMMING POOL SPA WADING POOL SPECIAL PURPOSE POOL WATER RECREATION ATTRACTION ACTIVITY POOL TYPE: TYPE: CHILD AMUSEMENT LAGOON WATER SLIDE WATERCOURSE RIDE WAVE POOL OTHER TYPE: FACILITY INFORMATION FACILITY NAME: FACILITY ADDRESS: ASSESSOR S PARCEL NUMBER: SECTION: TOWNSHIP: RANGE: TYPE OF FACILITY: HOME OWNER ASSOCIATION APARTMENT MOTEL/HOTEL HEALTH CLUB OTHER OWNER: OWNER ADDRESS: CONTRACTOR/ENGINEER INFORMATION (FILL IN ALL APPROPRIATE BOXES) POOL CONTRACTOR: ADDRESS: LICENSE NUMBER: ENGINEER/ARCHITECT: ADDRESS: LICENSE NUMBER: NAME, PRINT DATE SEAL SIGNATURE OF: ENGINEER A-10 A-10E ARCHITECT OTHER SOUTHERN NEVADA HEALTH DISTRICT APPROVAL BY: SIGNATURE DATE APPROVAL IS NOT INTENDED TO CONVEY APPROVAL FOR ANY MISTAKES OR OMISSIONS CONTAINED HEREIN. PROPER DEVELOPMENT IS THE RESPONSIBILITY OF THE VARIOUS PARTIES CONCERNED AND ALL APPLICABLE LAWS, RULES, AND REGULATIONS SHALL BE STRICTLY ADHERED TO. Revised 2/23/2015 jh Page 4 of 8

INFORMATION REGARDING REMODEL WORK TO BE DONE DESCRIBE SCOPE OF WORK IN DETAIL: MATERIALS USED (INCLUDE ALL PERTINENT INFORMATION INCLUDING MANUFACTURER, MODEL, COLOR ): SHEETS INCLUDED: YES NO PUMP CURVE AND FILTER/HEATER HEAD LOSS CURVES INCLUDED: YES NO IF ANY PART OF THE CIRCULATION EQUIPMENT OR SUCTION OUTLET COVERS WILL BE REMODELED, COMPLETE ALL CATEGORIES ON THE FOLLOWING TWO PAGES: Revised 2/23/2015 jh Page 5 of 8

TYPE: SPLIT DRAIN CHANNEL / UNBLOCKABLE SVRS OTHER CIRCULATION SUCTION OUTLET COVER(S): AUXILIARY SUCTION OUTLET COVER(S): CIRCULATION PUMP: AUXILIARY PUMP: COVER SIZE: INCH OPEN AREA: SQ. INCH QUANTITY: LOCATION: FLOOR WALL BOTH MINIMUM SPACING: 3 FT (SPA) 4 FT (POOL) CHANNEL OTHER COVER IS CERTIFIED BY: NSF IAPMO UL ENGINEER OTHER MAX VELOCITY FLOOR FPS MAX VELOCITY WALL FPS MAX FLOW RATE FLOOR GPM MAX FLOW RATE WALL GPM COVER IS SHARED WITH AUXILIARY SYSTEM: YES NO IDENTIFY: SUMP: MANUFACTURER FIELD FABRICATED OTHER FUNCTION: HYDROTHERAPY JET WATER FEATURE SOLAR HEATER WEIR FIRE SUPPRESSION SLIDE OTHER TYPE: SPLIT DRAIN CHANNEL / UNBLOCKABLE SVRS OTHER HYDROTHERAPY JET QUANTITY: OTHER DRAIN QUANTITY: COVER SIZE: INCH OPEN AREA: SQ. INCH SPACING: FT LOCATION: FLOOR WALL BOTH COVER IS CERTIFIED BY: NSF IAPMO UL HYDROSTATIC RELIEF VALVE INSTALLED: ENGINEER OTHER YES NO MAX VELOCITY FLOOR FPS MAX VELOCITY WALL FPS MAX FLOW RATE FLOOR GPM MAX FLOW RATE WALL GPM SUMP: MANUFACTURER FIELD FABRICATED OTHER FUNCTION: CIRCULATION HYDROTHERAPY JET WATER FEATURE SOLAR HEATER WEIR FIRE SUPPRESSION SLIDE OTHER QUANTITY: HP: RPM: MEETS NSF STD 50: YES NO PHASE: GPM: AT TDH GFCI PROTECTED: YES NO VARIABLE FREQUENCY DRIVE (VFD): YES NO VFD FUNCTION: CIRCULATION HYDROTHERAPY JET WATER FEATURE SOLAR HEATER WEIR FIRE SUPPRESSION SLIDE OTHER QUANTITY: HP: RPM: MEETS NSF STD 50: YES NO PHASE: GPM: AT TDH GFCI PROTECTED: YES NO VARIABLE FREQUENCY DRIVE (VFD): YES NO VFD Revised 2/23/2015 jh Page 6 of 8

FILTER: FILTER VALVE: FLOW REGULATING DEVICE: HEATER: DISINFECTANT FEEDERS: SECONDARY DISINFECTANT FEEDER: ph ADJUSTMENT FEEDER: SHEETS MUST BE AUTOMATED CONTROLLER: SHEETS MUST BE WASTE DISPOSAL: TYPE: SAND CARTRIDGE D.E. OTHER QUANTITY: TOTAL AREA: SQ.FT AIR RELIEF: AUTO MANUAL MEETS NSF STD 50: YES NO TYPE: MULTIPORT OTHER MEETS NSF STD 50: YES NO QUANTITY: SIZE: TYPE: GAS ELECTRIC SOLAR OTHER SIZE: BTU kw BYPASS YES NO INTERNAL YES NO MANUAL YES NO TYPE: LIQUID DRY CHEMICAL GAS IN-LINE ELECTROLYTIC CHLORINE GENERATOR QUANTITY: UL/ETL LISTED: YES NO MEETS NSF STD 50: YES NO MAXIMUM APPROVED TOTAL FEEDER CAPACITY: GALLONS FEEDER IS CERTIFIED BY: NSF IAPMO UL ENGINEER OTHER FEEDER IS ELECTRICALLY INTERLOCKED WITH PUMP: YES NO TYPE: OZONE ION UV/H 2 O 2 OTHER QUANTITY: UL/ETL LISTED: YES NO MEETS NSF STD 50: YES NO GFCI PROTECTED: YES NO OPERATED IN CONJUCTION WITH AN APPROVED DISINFECTANT FEEDER: YES NO FEEDER IS CERTIFIED BY: NSF IAPMO UL ENGINEER OTHER FEEDER IS ELECTRICALLY INTERLOCKED AS REQUIRED : YES NO TYPE: MURIATIC ACID SODIUM BISULFATE CO 2 SULFURIC ACID OTHER FEEDER IS CERTIFIED BY: NSF IAPMO UL ENGINEER OTHER FEEDER IS ELECTRICALLY INTERLOCKED AS REQUIRED : YES NO CONTROLLER IS CERTIFIED BY: NSF IAPMO UL ENGINEER OTHER TYPE: SUMP PIT D.E. SEPARATION TANK INCH AIR GAP TO SEWER CARTRIDGE RINSE TO: MOP SINK OTHER Revised 2/23/2015 jh Page 7 of 8

CERTIFICATION OF CONTRACTED SERVICES THIS FORM TO BE COMPLETED BY THE LEGAL OWNER OF FACILITY OR FACILITY REPRESENTATIVE FACILITY NAME: FACILITY INFORMATION FACILITY LOCATION: CONTRACTOR NAME: CONTRACTOR INFORMATION CONTRACTOR ADDRESS: CONTRACTOR CONTACT INFORMATION: CONTRACTING LICENCE TYPE: I hereby certify that I have contracted the services of the above listed person/company to complete the work required by this application and to assist in the preparation and submission of plans, applications, and calculations to the Southern Nevada Health District. I understand the following: 1. Remodel work cannot begin until written approval is obtained (Initial) 2. The body of water must close at the start of work until written approval of work and re-opening is obtained (Initial) 3. The body of water must pass a complete operational inspection at the time of the final remodel inspection (Initial) 4. Failure to pass either the final remodel or operational inspections will result in the body of water remaining closed and re-inspection fees being assessed (Initial) FACILITY REPRESENTATIVE NAME: (PRINT) TITLE: SIGNATURE: DATE: Revised 2/23/2015 jh Page 8 of 8