NURSE CALLING SYSTEM

Similar documents
medical and commercial f ields.

MediCom. MediCom AUSTCO. State of the art Hospital Emergency Call System. The very best in nurse call and. care management solutions

Rauland Responder 4000

Personal Health Monitoring Services SM VITAL SIGNS TRANSMITTER MODEL: VST 3 TM. Instruction Manual

GIVES YOU A CHOICE OF NURSE CALL.

Microprocessor Nurse Call System In-Service Training

Medical Grade Power Strips

Instant results with a simple touch

TELLIGENCE. Ascom. Nurse Call System. The complete patient-staff communication solution. Ascom

INTERNET OF THINGS BASE REMOTE PATIENT MONITORING SYSTEM

Rauland Responder 4000

Specifications, Performance & Submittal

Tunstall telehealth solutions

Allworx Reach and Reach Link

econsult econsult Introduction & Training Manual

NCS Nurse Call System. Bridging Communications & Care Delivery Services

Automatic Patient Care System using ARM Processor Abirami.K 1 Abinaya.S 2 Sinduja.B 3 Vedhapriya.V.G 4 Dr. N. Suthanthira Vanitha 5

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

Thomas Built Buses Using ServiceLink TBB Institute

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

Redefining Patient Handling. prevention

Genesis Touch Video Conferencing Customer Training. Honeywell HomMed

Full IP. nursecall and notification

SPOK MESSENGER. Improving Staff Efficiency and Patient Care With Timely Communications and Critical Connectivity

SMART HEALTH MONITORING SYSTEM

Practical Design of Intelligent Reminder System of Having Medicine for Chronic Patients

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS FOR NC300 MICROPROCESSOR NURSE CALL SYSTEM

Advanced Planning Brief to Industry 01 May 2012 PM-Towed Artillery Systems

Utkarsha Kumbhar *, Vaidehi Gadkari, Rohan Waichal, Prashant Patil ABSTRACT I. INTRODUCTION

Server, Desktop, Mobile Platforms Working Group (SDMPWG) Dated

Easylink to Square D Module

PARTNER FOR PROFIT. Reap the Rewards of the Fieldprint Station Site Network Partner Program

Project Statement. Medicine Reminder Device & Shampoo/Conditioner Identification Device. Team #5 Sheldon Bish Karla Sittnick Kenta Umetsu

Case Study Hospital Integrates Remote, Real-Time Monitoring Data from Isolation Unit

HT1611C Timer with Dialer Interface

Telligence Nurse Call Communication System. Total solutions for patient-staff communications

WHITE PAPER HOSPITAL DESIGN AND HIPAA: The Changing Face of Patient Privacy

Safe & Sound Video and audio baby monitor User guide Models: BM3000/ BM3000 Twin

Nurse Call System. A Voice over IP Based Solution for Streamlined Communication, Alerting and Workflow

Telehealth. Putting the patient at the heart of the journey

Wireless Nurse Call System Designed with you in mind

Extreme Collaboration. Tim Price-Walker Enterprise Business Consultant, Steljes

Application Notes for IgeaCare ApoloDS with Avaya IP Office Issue 1.0

CSU STANISLAUS SCHOLARSHIPS REVIEWER S GUIDE

smart technologies Neonatal incubator from standard to intensive care

SOFTWARE REQUIREMENTS SPECIFICATION Hospital Management System

Connect Your Universe The complete solution for emergencies, events and every day

A Design and Implementation of a Smart Bed for Elderly Patients

Telergon DC Isolators. for Photovoltaic applications

smart technologies Neonatal incubator from standard to intensive care

CAP IP. ip intercom REFUGE CALL POINTS IP NETWORK SALES DEPARTMENT SECURITY DISPATCH SMARTPHONE SUPERVISION IP MAYLIS RANGE

... Top Quality Assurance Bizerba CWE Checkweigher

Le Moyne College. BEICKERT AUDIO 219 Arnold Ave, Syracuse, NY Thomas J. Niland Jr. Athletic Complex SOUND STUDY QUOTATION.

ELECTRONICS TECHNICIAN I ELECTRONICS TECHNICIAN II

10 Things To Know About

Happy patients, healthy patients. Solutions for interactive patient care

GLOBALMEET FOR iphone. GLOBALMEET FOR iphone USER GUIDE

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

HEALTH WORKFORCE SUPPLY AND REQUIREMENTS PROJECTION MODELS. World Health Organization Div. of Health Systems 1211 Geneva 27, Switzerland

IPiN SYSTEM DESCRIPTION.

Isolette TI500 Neonatal Transport

CDRL A006 Training Manual User's Guide for STAT! TM EMEDS ICU Serious Medical Game. Release v November 26, 2014

Integrated Nurse Call Solutions

FoodTech Calibration Software for Windows 98 and up

WELCOME TO THE INNOVATION UNIT Phase 2 Mobile Devices YOUR TRAINING GUIDE August 2015

ENTERPRISE with people in mind

PREMATURE INFANT INCUBATOR ALERT SYSTEM VIA SMS

Site Install Guide. Hardware Installation and Configuration

Raiser s Edge: How To Query Constituent Giving With A Cumulative Total Including Soft Credits

Feel at home. No matter where you stay. TECHNICAL MANUAL

Cabin Crew B787 SOP Cabin Layout Aircraft Configuration Special Seating Requirements Cabin Crew Stations Interphone Dimmable Window

GLOBALMEET GLOBALMEET WEB & AUDIO USER GUIDE

Improve response times, availability and decision making for better quality of care with pocket-sized mobile voice and data

Comprehensive Staff and Patient Communications: Emphasizing Patient-Centered Care

See the Pressure you re up against...

REQUEST FOR PROPOSAL INSTRUCTOR AUDIO-VISUAL PODIUMS FOR ILLINOIS VALLEY COMMUNITY COLLEGE PROPOSAL #RFP2013-P06

Sanilac County Community Mental Health Authority

NOTE ON PERFORMANCE TESTING

BASIC OPERATION OF L&L KILNS WITH A ONE-TOUCH

Copyright 2013 GE Multilin Inc. All rights reserved. Power Management Control System (PMCS) software revision EnerVista, Integrator, Digital

Enabling Safe Multi-Computer Usage with Flash Memory. Flash Memory Summit Session 101 Consumer Applications Panelist: Jay Elliot

SECTION NURSE CALL/CODE BLUE SYSTEM (JERON)

Hand-hygiene Systems Provide Compliance Help

Universal Armament Interface (UAI)

Purpose/Goal: This course introduces the purpose and use of Smart Chart as a means of legal documentation.

Department of Aerospace Engineering ROCKET COMPETITION SPOT LANDING

TELLIGENCE. Workflow Solutions. Integrated Workflow Intelligence. Ascom

Redefining Patient Handling. prevention

Getting Started: Creating a New Account and Logging In

SMS in Hospitals. Communicate with all your stakeholders to improve the efficiency and effectiveness of the care you provide

CareBase: A Reference Base for Nursing

GLOBALMEET GLOBALMEET USER GUIDE

InTouch Critical Care Bed. Basic needs. Simplified care. Exceptional outcomes.

Marine Corps Warfighting Laboratory. Dragon Fire II Experimental System NDIA Briefing

-For Residents of Kanagawa Prefecture- Make your own MY ME-BYO Record to manage your health and prepare for emergencies

Wissner-Bosserhoff Aged Care Furniture

GE Healthcare. B40 Patient Monitor Connecting intelligence and care

Alaris System. Medication safety system focused at the point of care

Operating Manual for HEKA Incubators

BTR-3E ARMOURED TROOP CARRIER CREW TRAINING COMPLEX

Transcription:

NURSE CALLING SYSTEM Patients' care is undoubtedly the main aim of all hospitals and Nursing Homes. Hence there is a need to provide one dedicated line of communication to every patient so that the patient can draw attention of a nurse from his bed whenever required. The resources that patients look for are good doctors, good medical equipments and timely care. Hence it is very much essential to have foolproof system by means of which patient can communicate with nurses/doctors to seek their help. In rapidly changing world, it is becoming essential for nurses only to take care of patients 24 hours without much help from kith & kin of patients. Nursing needs to focus on Quality care and extend utmost importance to the service of the patients and develop a sense of responsibility and accountability of total nursing with compassionate heart. Our Nurse Call System is designed keeping in view the relevance of quality nursing in today s context and gives topmost priority to it. Installing our NCS in the hospital enables efficient management of nursing staff.

PRODUCT FEATURES Designed by highly experienced engineers. Room Number Display tailor made to customer requirements. Working successfully since past 5 Years. Cost effective, efficient, compact and highly reliable. Maintenance free. Makes use of super bright 7segment LEDs to enhance the life of indicators and reduce power consumption. Voice module with Standard voice patient wants you Please Assist instead of buzzer makes it distinguished. Very low working voltage to ensure patient's safety. Very simple design to make it easily installable and Maintenance free. Call from a patient remains registered till the nurse attends the patient and clears the call from his room.

SPECIFICATIONS 1. MAIN MICRO CONTROLLER BASED NURSE CALLING DISPLAY UNIT. This is a Microcontroller based device placed in the nurse station with static windows which displays the room number of the calling patient and also it has a voice module to announce the call. There are two buttons on it, Power Button: Press switch turns the device ON.. Mute Button: It is for acknowledging a call from patient. It will make the window steady and It will silences the voice module until a call is cleared. Fuse protection:. Protection against high AC Mains Voltage & Protection for call units Volume control : Volume To adjust the volume of Voice Message No. of Windows : Maximum 12 Dimension : 400(H X 345W X 100D mm Light Source : Super Bright 7 segmsent LEDs Operating Voltage : 12V DC Current : 50 MA Maximum Visual Indication : Through RED LED. Dimensions : 345mm (L) x 400mm (W) x 100mm (D) Operating Temperature : 0 to 50 degree Celsius

2. MICRO CONTROLLER BASED REMOTE NURSE CALLING DISPLAY UNIT (LCD). 4 X 20 LCD used to display the bed numbers. This Unit can be placed remotely from Main Nurse Station MAIN FEATURES Built in Power Supply. Built in Voice Message. Mute Switch-To silence Voice Message. User friendly display-back lit LCD (Liquid Crystal Display (4x20)80 Characters. LCD gives Room number/ Bed Number. TECHNICAL SPECIFICATIONS Mains Input Voltage : 230V A.C, 50Hz+/-10V Secondary Voltage : 5V. DC Normal Current Consumption : 50mA @ 230V : And 100mA @ 5V D.C Maximum Current Consumption: 200mA @ 230V : And 500mA @ 5V Enclosure : CRCA Fabricated Wall mounting type Dimensions : 300(H)x340(L)x100(D)mm

3. MICRO CONTROLLER BASED CALL UNITS The unit is designed with soft touch key pad consisting of one key for call initiation and another for clearing call which is required to be done by the nurse after attending the patient. Additional push button switch is integrated to this unit by means of a coil cord to enable a patient to initiate a call from the bed itself. Operating Voltage Current Visual Indication Switch Operation Dimensions : 12V DC : 25 MA maximum. : RED LED : More than 100000 operations assured : 90mm(L) x 90mm(W) x 50mm(D)

4. MICRO CONTROLLER BASED GSM SMS UNIT FOR EMERGENCY INDICATION If any call is not attended for 5 Minutes/30 Minutes, SMS will be sent to configured mobile numbers through GSM / GPRS modem. MAIN FEATURES Built in Power Supply. User friendly unit. Built in high Sensitive antenna. Built in Sim Card Tray. 160 characters for each message. Unlimited cell phone numbers can be entered. TECHNICAL SPECIFICATIONS Mains Input Voltage : 230V A.C, 50Hz+/-10V Secondary Voltage : 5V. DC Normal Current Consumption : 50mA @ 250V : And 100mA @ 5V D.C Maximum Current Consumption: 200mA @ 230V : And 500mA @ 5V Enclosure : CRCA Fabricated Wall mounting type Dimensions : 240(H)x 255(L)x70(D)mm

5. PC BASED SOFTWARE TO LOG THE CALLS It is a DOS based software which is connected to COM port of the PC. All the call request and call attended for each bed will be logged and Date Wise report can be provided. Delay time will be provided between call requested and call attended.