Pressure IQ Evolve Mattress Replacement System USER MANUAL

Similar documents
BariMaxx Active Therapy System

Citadel Bed Frame System

Bed Rail & Inspection Policy and Procedure Checklist

9/17/2015. Bed Rail Safety A Clinical Process Guideline. Background. Federal Nursing Home Reform Act

Bed Rail Safety A Clinical Process Guideline. Laura Funsch, RN, BSN, MS, Director of Regulatory Strategy

Bed Rail Entrapment Risk Notification Guide

Oregon Health & Science University Department of Surgery Standard Precautions Policy

BED RAIL SAFETY 9/15/2015. A Clinical Process Guideline. Background. Federal Nursing Home Reform Act

User-Service Manual Joerns Assist Handle Model F025

SPECIFICATIONS FOR TENDER # SUPPLY OF HOSPITAL CRITICAL CARE BED FOR WESTERN HEALTH

Instruction for use and trouble shooting guide

Lift Repositioning and Turning Accessory Operating Instructions

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

INTRODUCTION. AUTHORIzATION A Word of Caution

Access to the laboratory is restricted when work is being conducted; and

Of Critical Importance: Infection Prevention Strategies for Environmental Management of the CSSD. Study Points

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

Simply Practical. The Hill-Rom CareAssist ES Hospital Bed

Propad MATTRESS OVERLAYS, CUSHIONS AND ACCESSORIES MSS. Distributed by:

EXPOSURE CONTROL PLAN

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

ISOLATION TABLE OF CONTENTS STANDARD PRECAUTIONS... 2 CONTACT PRECAUTIONS... 4 DROPLET PRECAUTIONS... 6 ISOLATION PROCEDURES... 7

There were 40 residents on 28/07/2007. The Nursing Home is currently fully registered for 50 residents.

Linen Services Policy

Medication Aide Skills Assessment Review Guide

Infection Control and Prevention On-site Review Tool Hospitals

SMP 385MT. Solutions Start Here... Solutions Start Here USER & MAINTENANCE MANUAL

Citadel Plus Bariatric Care System

PERSONAL PROTECTIVE EQUIPMENT (PPE) Standard Operating Guidance

Simply Intuitive. The Hill-Rom Advanta 2 Bed

BLOODBORNE PATHOGENS EXPOSURE PREVENTION POLICY AND PROCEDURE BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

C: Safety. Alberta Licensed Practical Nurses Competency Profile 23

OPERATING ROOM ORIENTATION

Infection Control Checklist for Dental Settings Using Mobile Vans or Portable Dental Equipment. Guiding Principles of Infection Control:

Bed Rail Provision Guidance for Assessment and Provision. Clinical & Prescriber Support Special Interest Group

Check List Putting On (Donning) PPE Removing (Doffing) PPE. Sources: Victorian Ebola Virus Disease Plan Version 2: 12 November 2014.

MODULE 22: Contingency Planning and Emergency Response to Healthcare Waste Spills

ENTERPRISE with people in mind

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

2016 School District of Pittsburgh

Understand nurse aide skills needed to promote skin integrity.

& ADDITIONAL PRECAUTIONS:

A Health and Safety Tip Sheet for School Custodians. Did you know? Step 1. Identify job hazards. Step 2. Work towards solutions

3.03 Functions of support services personnel Name

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

FIRST AID POLICY. (to be read in conjunction with Administration of Medicines Policy) CONTENTS

Best Practice Guidelines - Storing and Handling Clean Linen in Healthcare Facilities

Ebola guidance package

Eleganza 3XC. Designed for ICU

FlexoStretch. Product Description. Instruction Guide

Infection Prevention, Control & Immunizations

Shetland NHS Board Standard Operating Procedure for Cleaning, Maintenance, Audit and Replacement of Mattresses

NJ Dept of Health Central Service Standards SUBCHAPTER 8. CENTRAL SERVICE. 8:43G-8.1 Central service policies and procedures

Worksheet: Friend, Foe or Both?

PRACTICE SELF-AUDIT TOOL FOR EXTERNAL FULL PORFOLIO (EFP) APPLICANTS

Ave 2 Birthing Bed. Welcome to the world

SOUTH DARLEY C of E PRIMARY SCHOOL INTIMATE AND PERSONAL CARE POLICY

INFECTION CONTROL CHECKLIST Nursing Department

Everyone Involved in providing healthcare should adhere to the principals of infection control.

SAMPLE: Environmental Rounds and Safety Assessment Tool

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

INSTITUTIONS REGULATION, 1981

MMO

Affinity Four Birthing bed Delivering Safety

Hygiene Policy. Arrangements for Review:

Infection Prevention Implementation and adherence to infection prevention practices are the keys to preventing the transmission of infectious diseases

BEREWOOD PRIMARY SCHOOL

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

Pharmacy Sterile Compounding Areas

Home+ Home+ Home Infusion. Home Infusion. regionalhealth.org/home

Burn Intensive Care Unit

Hill-Rom Advanta 2 Bed Tips Simply Intuitive FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE ADVANTA 2 BED, SEE USER S MANUAL.

Infection Control Care Plan. Patient Demographic / label. Hospital: Ward:

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings

WHEELING-OHIO COUNTY BOARD OF HEALTH WHEELING-OHIO COUNTY HEALTH DEPARTMENT

Health and Safety Policy

Caution! triangles are used to warn of situations that demand extra care and attention.

Bloodborne Pathogens Exposure Control Plan. Approved by The College at Brockport, Office of Environmental Health and Safety, February 2018

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Assessment Tool Environmental Services

The Lee Wiggins Childcare Centre OCCUPATIONAL HEALTH AND SAFETY POLICY

Some Exposure: There could be occupational exposure, but not as a part of their normal work routine.

ConCerto Shower trolley

The environment. We can all help to keep the patient rooms clean and sanitary. Clean rooms and a clean hospital or nursing home spread less germs.

Standard Precautions

How to Use Our Pillows

Routine Practices. Infection Prevention and Control

COMPETENCIES FOR FOOD AND NUTRITION SERVICES EMPLOYEES

Protection and Convenience For You and Your Patient

Home Care Aide Skills Checklist

Infection Control Policy EDITION 5

Continuing Care Health Service Standards Standard 11.0 Audit Readiness Checklist (ARC)

- E - COMMUNICABLE DISEASES AND INFECTIOUS DISEASE CONTROL

STANDARD OPERATING PROCEDURE (SOP) TERMINAL CLEAN OF ISOLATION ROOMS

Decontamination of equipment

AvantGuard bed Safety by design. Information

Equipment Cleaning Guidelines Template

West Virginia University

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Transcription:

Pressure IQ Evolve Mattress Replacement System USER MANUAL P/N 413657-AH Rev C 01/2015...with people in mind

IMPORTANT INFORMATION FOR USERS ARJOHUNTLEIGH HEREBY DISCLAIMS ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ON THE ARJOHUNTLEIGH PRODUCT AS DESCRIBED IN THIS PUBLICATION. ANY WRITTEN WARRANTY OFFERED BY ARJOHUNTLEIGH SHALL BE EXPRESSLY SET FORTH IN THIS PUBLICATION OR INCLUDED WITH THE PRODUCT. UNDER NO CIRCUMSTANCES SHALL ARJOHUNTLEIGH BE LIABLE FOR ANY INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES AND EXPENSES, INCLUDING DAMAGES OR INJURY TO PERSON OR PROPERTY, DUE IN WHOLE OR IN PART TO THE USE OF THE PRODUCT OTHER THAN THOSE FOR WHICH DISCLAIMER OF WARRANTY OR LIMITATION OF LIABILITY IS EXPRESSLY PROHIBITED BY SPECIFIC, APPLICABLE LAW. NO PERSON HAS THE AUTHORITY TO BIND ARJOHUNTLEIGH TO ANY REPRESENTATION OR WARRANTY EXCEPT AS SPECIFICALLY SET FORTH IN THIS PARAGRAPH. Descriptions or specifications in ArjoHuntleigh printed matter, including this publication, are meant solely to generally describe the product at the time of manufacture and do not constitute any express warranties, except as set forth in the written limited warranty included with this product. Information in this publication may be subject to change at any time. Contact ArjoHuntleigh for updates. In order for ArjoHuntleigh products to perform properly, ArjoHuntleigh recommends the following conditions. Failure to comply with these conditions will void any applicable warranties. Use this product only in accordance with these instructions and applicable product labeling. Assembly, operations, adjustments, extensions, modifications, technical maintenance or repairs must be performed only by qualified personnel authorized by ArjoHuntleigh. Contact ArjoHuntleigh for information regarding maintenance and repair. Specific indications, contraindications, warnings, precautions and safety information exist for ArjoHuntleigh s therapeutic support systems. It is important for users to read and familiarize themselves with these instructions and to consult the treating physician prior to patient placement and product use. Individual patient conditions may vary.

Table Of Contents Introduction... 2 Indications...2 Contraindications...2 Risks and Precautions...2 Safety Information...2 Preparation for Use... 4 Patient Placement and Nursing Care... 4 Skin Care...4 Incontinence / Drainage...4 Product Characteristics... 5 Care and Cleaning... 6 General Instructions...6 Cleaning Mattress During Patient Use...6 Cleaning Mattress After Patient Use...6 Recommended Wipe-Down Procedure...6 Recommended Laundering Procedure...7 Preventive Maintenance Schedule... 8 Daily Cleaning...8 Inspection / System Check-Out...8 Troubleshooting... 8 Replacement Parts... 9 Specifications... 10 Customer Contact Information... 10 Symbols Used... 11 1

Introduction It is recommended that all sections of this user manual be read prior to product use. Carefully review the Indications, Contraindications, Risks and Precautions and Safety Information prior to placing a patient on any Pressure IQ Evolve Mattress Replacement System (MRS). Caregivers should discuss Safety Information, Risks and Precautions and Contraindications with the patient, the patient s family and / or legal guardians. Save this manual in an easily accessible place for future reference. The Pressure IQ Evolve MRS is a non-powered pressure redistribution mattress replacement system which uses Self Adjusting Technology (SAT) to provide pressure redistribution therapy. The SAT system is composed of 45 inter-connected air pods contained within a foam shell. The system is designed for patients weighing up to 500 lb (227 kg). Indications The Pressure IQ Evolve MRS is intended to treat and prevent stage I through IV pressure ulcers. Contraindications The Pressure IQ Evolve MRS is contraindicated for patients with the following conditions: unstable vertebral fracture cervical and skeletal traction Risks and Precautions Transfer - Standard precautions should be taken during patient transfer. Side Rails and Restraints - WARNING: Use or non-use of restraints, including side rails, can be critical to patient safety. Serious injury or death can result from the use (potential entrapment) or non-use (potential patient falls) of side rails or other restraints. See related Safety Information. Patient Migration - Specialty surfaces have different shear and support characteristics than conventional surfaces and may increase the risk of patient movement, sinking and / or migration into hazardous positions of entrapment and / or inadvertent bed exit. Monitor patients frequently to guard against patient entrapment. Safety Information Skin Care - Monitor skin conditions regularly and consider adjunct or alternative therapies for high acuity patients. Give extra attention to any possible pressure points and locations where moisture or incontinence may occur or collect. Early intervention may be essential to preventing skin breakdown. Patient Weight - The maximum patient weight for this device is 500 lb (227 kg). In addition, consult the specifications for the bed frame being used. Additional weight limitations may apply. Patient Entrance / Exit - Caregiver should always aid patient in exiting the bed. Make sure a capable patient knows how to get out of bed safely (and, if necessary, how to release the side rails) in case of fire or other emergency. 2

Bed Frame - Bed frame precautions should be considered when used in conjunction with the Pressure IQ Evolve surface. Always use a standard healthcare frame with safeguards or protocols that may be appropriate. Bed frame and side rails (if used) must be properly sized relative to the mattress to help minimize any gaps that might entrap a patient s head or body. It is recommended that bed and side rails (if used) comply with all applicable regulations and protocols. Side Rails / Patient Restraints - Whether and how to use side rails or restraints is a decision that should be based on each patient's needs and should be made by the patient and the patient's family, physician and caregivers, with facility protocols in mind. Caregivers should assess risks and benefits of side rail / restraint use (including entrapment and patient falls from bed) in conjunction with individual patient needs, and should discuss use or non-use with patient and / or family. Consider not only the clinical and other needs of the patient but also the risks of fatal or serious injury from falling out of bed and from patient entrapment in or around the side rails, restraints or other accessories. In the US, for a description of entrapment hazards, vulnerable patient profile and guidance to further reduce entrapment risks, refer to FDA's Hospital Bed System Dimensional and Assessment Guidance To Reduce Entrapment. Outside the US, consult the local Competent Authority or Government Agency for Medical Device Safety for specific local guidance. Consult a caregiver and carefully consider the use of bolsters, positioning aids or floor pads, especially with confused, restless or agitated patients. It is recommended that side rails (if used) be locked in the full upright position when the patient is unattended. Make sure a capable patient knows how to get out of bed safely (and, if necessary, how to release the side rails) in case of fire or other emergency. Monitor patients frequently to guard against patient entrapment. When selecting a standard mattress, ensure the distance between top of side rails (if used) and top of mattress (without compression) is at least 8.66 in (220mm) to help prevent inadvertent bed exit or falls. Consider individual patient size, position (relative to the top of the side rail) and patient condition in assessing fall risk. Bed Height - To minimize risk of falls or injury, the bed should always be in the lowest practical position when the patient is unattended. Brakes - Caster brakes should always be locked once the bed is in position. Verify wheels are locked before any patient transfer to or from the bed. Head of Bed Elevation - Keep head of bed as low as possible to help prevent patient migration. No Smoking in Bed - Smoking in bed can be dangerous. To avoid the risk of fire, smoking in bed should never be allowed. General Protocols Avoid contact of sharp instruments with the Pressure IQ Evolve MRS. Punctures, cuts and tears will prevent proper operation. Follow all applicable safety rules and institution protocols concerning patient and caregiver safety. Disposal - At the end of useful life, dispose of waste according to local requirements or contact the manufacturer for advice. 3

Preparation for Use 1. Open shipping container(s). Do not use sharp instruments to open boxes. Damage to mattress could result. 2. Remove Pressure IQ Evolve MRS from plastic protective cover. The MRS cover may appear wrinkled when unpacked. To remove wrinkles, allow MRS up to 24 hours to adjust; see Troubleshooting table for more information. Wrinkles will not affect inflation or function, so MRS may be used immediately if needed. 3. Check MRS surface for tears or cracking; do not use if tears or cracks are present. 4. If re-installing MRS onto a new frame or for a new patient, check surface for staining and soiling; clean and / or disinfect as required (see Care and Cleaning). 5. Level bed and lock brakes. 6. Remove existing mattress from bed frame. 7. Position MRS on bed frame with logo facing up and product information tags at foot end of bed. Ensure there are no gaps between MRS and bed frame or side rails. Always use a standard health care bed frame with safeguards or protocols that may be appropriate. Frame and side rails must be properly sized relative to the mattress to help minimize any gaps that might entrap a patient s head or body. Patient Placement and Nursing Care It is recommended that all sections of this manual be read prior to patient placement and nursing care. Carefully review the Contraindications, Safety Information, and Risks and Precautions sections prior to placing a patient on the Pressure IQ Evolve MRS. 1. Transfer patient following all applicable safety rules and institution protocols. 2. Center patient side-to-side and head-to-foot on Pressure IQ Evolve MRS surface. 3. Ensure all sections of the MRS fully support the patient. Skin Care Remove excess moisture and keep skin dry and clean. Check patient s skin regularly, particularly in area where incontinence and drainage occur. Ensure linens under patient are not wrinkled. Incontinence / Drainage Use moisture-impermeable underpads for incontinent patients. Wipe surface clean and replace bed linens as required (see Care and Cleaning). 4

Product Characteristics The Pressure IQ Evolve MRS is a non-powered air mattress providing high immersion for the patient to maximize pressure relief and redistribution. The helix design of the Pressure IQ Evolve MRS air pods results in product characteristics that can be identified by the following: As a non-powered air mattress, a certain amount of indentation in the therapeutic section can be expected. Mattress indentation may make it challenging for the caregiver to perform some tasks, such as patient repositioning. After normal use, it is typical for the Pressure IQ Evolve MRS to have up to 2.5 in (6.3 cm) indentation in the therapeutic section. ArjoHuntleigh has confirmed that the Pressure IQ Evolve MRS continues to provide patient pressure redistribution and performs as intended. The image below illustrates how the measurement is performed: An ArjoHuntleigh Representative can confirm with the following steps that the Pressure IQ Evolve MRS is operating within product specifications: 1. Ensure the mattress is resting on a flat, stable surface (do not perform this procedure on a bedframe with a curved deck or in an articulated position; do not remove the cover for this process). 2. Use a light straight edge a few inches longer than the width of the mattress to aid in measurement. 3. Place the straight edge 33 in (84 cm) to 39 in (99 cm) from the head edge of the mattress perpendicular to the mattress length (this should be the mattress center point). 4. Use a scale, tape measure or straight ruler to measure from the bottom of the straight edge to the center of the mattress surface, taking care not to push the end of the measurement tool into the foam. 5. The mattress should have an indentation of less than 2.5 in (6.3 cm); if the measurement is equal to or greater than 2.5 in (6.3 cm), further investigation and warranty replacement may be necessary. For additional questions regarding the Pressure IQ Evolve MRS or these evaluation steps, please contact an ArjoHuntleigh representative. 5

Care and Cleaning General Instructions Do not clean with solvents. To disinfect, use only approved disinfectants diluted in accordance with manufacturer s instructions. When body fluids, including blood, are present, use the following throughout all cleaning procedures: disposable, powder-free latex or latex-free gloves protective clothing, including disposable or reusable impervious apron or gown protective eyewear and face shield, as necessary SOAP SOLVENT Cleaning Mattress During Patient Use The Pressure IQ Evolve MRS should be wiped daily with a mild soap and water solution. Always use standard precautions, treating all used equipment as contaminated. Institutions should follow local protocols for cleaning and disinfection. 1. Remove or push bed linens to center of mattress. 2. Wipe and rinse any soiling from the mattress surface. 3. Dry surface with towel. 4. Ensure bed linens are refitted and not wrinkled under patient. Cleaning Mattress After Patient Use The Pressure IQ Evolve MRS must be disinfected after each patient use. It may be disinfected by wipe-down and cover may be laundered. Always use standard precautions, treating all used equipment as contaminated. Institutions should follow local protocols for cleaning and disinfection. Recommended Wipe-Down Procedure 1. Wash entire mattress surface with a coarse cloth using an approved disinfectant germicide mixed to manufacturer s instructions. 2. Wipe and rinse surface. 3. Disinfect clean surface with a chlorine solution mixed to proper concentration, 1:100 (two ounces of chlorine bleach to one gallon of water). Using a clean cloth, wring out excess chlorine solution until cloth is damp. Wipe entire surface with damp cloth. 4. Allow to air dry. 6

Recommended Laundering Procedure 1. Remove mattress from frame and set on a hard smooth surface with logo side facing down. 2. Unzip all three sides of cover and remove from foam shell. 3. Hand or machine wash cover (gentle cycle, 120 F / 49 C) in mild detergent. 4. Tumble dry at low heat setting. Do not use bleach. 5. Place the laundered cover over the foam shell ensuring that the tags are located at the foot end where the foam shell slopes and the zipper pull ends. 6. Carefully flip mattress over and zip all three sides closed. 7

Preventive Maintenance Schedule Preventive Maintenance for the Pressure IQ Evolve MRS consists of regular cleaning (see Care and Cleaning) and an overall system check-out to be performed at the intervals described below. All components must be cleaned, disinfected and inspected after each patient s use and before use by a new patient. Always use standard precautions, treating all used equipment as contaminated. Institutions should follow local protocols for cleaning and disinfection. Daily Cleaning The MRS should be wiped daily with a mild soap and water solution. Inspection / System Check-Out Check each of the following before placing the Pressure IQ Evolve MRS with a new patient: 1. Check MRS for tears or cracking; do not use if tears or cracks are present. 2. Ensure MRS is free of stains and is not overly faded. Troubleshooting Do not attempt troubleshooting outside this manual or where the solution recommends to contact ArjoHuntleigh. Any unauthorized service, modification, alteration, or misuse may lead to serious injury and / or product damage and will void all applicable warranties. Symptom Possible Cause Solution Mattress too firm upon arrival. Difference in altitude not sufficient to open valves. Apply weight to mattress to open valves. Mattress cover too wrinkled upon removal from shipping container. Internal components have not adjusted to environment. This does not affect inflation or function. Let mattress adjust for 24 hours. If problem continues, contact ArjoHuntleigh for assistance. 8

Replacement Parts Do not attempt troubleshooting, maintenance, or parts replacement outside this manual or where the solution recommends contacting ArjoHuntleigh. Any unauthorized service, modification, alteration or misuse may lead to serious injury and / or product damage and will void all applicable warranties. Replaceable Pressure IQ Evolve MRS components are listed below. For more information such as pricing or additional spare parts that are not on this list, please contact your local ArjoHuntleigh representative. Replacement Part Cover - Navy SOFlux Top, Black Non-Skid Bottom Cover - Navy SOFlux Top, Grey Vinyl Bottom Cover - Navy DermaPlush Top, Black Non-Skid Bottom Cover - Grey DermaPlush Top, Black Non-Skid Bottom Cover - Navy DermaPlush Top, Grey Vinyl Bottom Cover - Grey DermaPlush Top, Grey Vinyl Bottom User Manual Foam Shell SAT System EVCSONB(SIZE)N* EVCSOVG(SIZE)N* EVCDPNB(SIZE)N* EVCDPNB(SIZE)G* EVCDPVG(SIZE)N* EVCDPVG(SIZE)G* 413657-AH PIQ-EV-FS-(SIZE)* PIQ-EV-SAT Reorder Number Cover Foam Shell SAT System * Width and length size should be specified when ordered. See specifications section for range of available widths and lengths. 9

Specifications Specifications subject to change without notice. Maximum Weight Capacity...500 lb (227 kg) Mattress: Mattress Weight...36 lb (16.33 kg) Mattress Length... 76-84 in (193.04-213.36 cm) Mattress Width... 32-38 in (81.28-96.52 cm) Mattress Height...8 in (20.32 cm) Storage / Operating Conditions: Temperature Range...57.2 F (14 C) to 95 F (35 C) Shipping Conditions: Temperature Range... -20.2 F (-29 C) to 140 F (60 C) Customer Contact Information For questions regarding this product, supplies, maintenance or additional information about ArjoHuntleigh products and services, please contact ArjoHuntleigh or an ArjoHuntleigh authorized representative. 10

Symbols Used Warning of possible hazard to system, patient or staff Important operational information Foot End Conforms to the Medical Devices Directive (93/42/EEC) and has been subject to the conformity procedures laid down in the council directive Consult Instructions for Use Manufacturer 500 lb 227 kg Safe Working Load Machine Wash, Gentle ( 120 F / 49 C) Tumble Dry, Normal Low Heat Do Not Dryclean Date of Manufacture 11