Rotonivo. Series RN 3000 RN 4000 RN Instruction manual

Similar documents
Telergon DC Isolators. for Photovoltaic applications

TABLE OF CONTENTS FINAL ASSEMBLY (3 WIRE)... 1 FINAL ASSEMBLY (2 WIRE)... 2 DOOR ASSEMBLY (3 WIRE)... 4 DOOR ASSEMBLY (2 WIRE)...

66CF1005 Certificate lifting equipment with new delivery Pag. 64/03

TECHNICAL MANUAL OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Distribution Statement A: Approved for public release; distribution is unlimited.

TECHNICAL MANUAL OPERATOR'S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

ELECTRICAL INSPECTION ACT CANADIAN ELECTRICAL CODE REGULATIONS

Operating Manual for HEKA Incubators

Eleganza 3XC. Designed for ICU

Parts List. Commercial Series Refrigerated Kitchen Equipment

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

ARMY TM AIR FORCE TO 35C MARINE CORPS TM 10155A-13/1

Approved for public release. Distribution is unlimited.

Medical Grade Power Strips

The Plug-In Coupling System.

GBH 24 VFR GBH 24 VRE

medical and commercial f ields.

PC-1600 Mech 230/460v PC v BL PC v BL PC-1300 Mech 230/460v

Amphenol Heavy Duty Cylindrical Connectors

Easylink to Square D Module

Medical furniture OPTIMA OBSTETRIC BED

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE 2A & 2B Raja S.C.Mullick Road Jadavpur, Kolkata

Smoke Control BACnet PTEC Unit Vent Controller. Control Applications. Product Description. Product Numbers

Thank you for purchasing the Actuator Systems NextBolt fingerprint deadbolt.

Siemens TEC Unit Vent 0-10V Output Controller. Accessories. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

1. Perform maintenance tasks associated with L120 and SMB actuators: 3. Evaluate L120 and SMB actuators for correct operation.

AIR CONDITIONER HORIZONTAL, COMPACT, 9,000 BTU/HR, 115 VOLT SINGLE PHASE 50/60 HERTZ PART NO. S8450-9KC-1H (NSN ) (EIC: N/A)

PSA 2017 Paper Improved Tornado Missile Risk Analysis Using Nonlinear Finite Element Analysis of Nuclear Power Plant Structures.

Isolette TI500 Neonatal Transport

AMC 30% 40% 10% 20% Electric power(kw) kw 25,44. Rotation speed (rpm) rpm 40,00. Got the Cochlea to reach the maximum availability of water

More comfortable childbirth

smart technologies Neonatal incubator from standard to intensive care

A. General provisions and other electrical systems are specified in other Sections of Division 26.

TECHNICAL MANUAL. DISTRIBUTION STATEMENT A : Approved for public release; distribution is unlimite.

Specifications, Performance & Submittal

Perform Primary Voltage Live-Line Testing Status: Approved

Document source:

VERTICAL TURBINE. PUMPS Repair Parts Table

... Top Quality Assurance Bizerba CWE Checkweigher

Image 3. exclusive design to meet all your needs

MCC. SMBJP6KE6.8(C)A THRU SMBJP6KE550(C)A. Features. Transient Voltage Suppressor 6.8 to 550 Volts 600 Watt.

KANOPY INTRODUCTION PRODUCT SPECIFICATION

Lodestar. Series. Specification Sheet. Application. Features. Floodlight. Tunnel Lighting. Parking Applications. Canopy Lighting Wash Lighting.

OPERATOR S MANUAL GENERATOR SET, SKID MOUNTED, TACTICAL QUIET

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

CARRIER, PERSONNEL, FULL TRACKED, ARMORED, M113A CARRIER, COMMAND POST, LIGHT TRACKED, M577A

NOTE ON PERFORMANCE TESTING

CERTIFICATES OF ELECTRICAL SAFETY RESPONSIBILITY OF RECs AND ELECTRICIANS

RETAIL PRICELIST. Effective from May Unit 3, 10 Achievement Way Wangara WA 6065 Ph: Fax:

Catalogue. Surge protective devices UL range OVR NE12 and OVR T2

TARGUS NOTEBOOK SECURITY DEFCON SCL SERIALIZED COMBINATION CABLE LOCK

TECHNICAL MANUAL OPERATOR'S, UNIT AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

SPECIAL SPECIFICATION 1849 ATM Switch Single-Mode OC-12 Module

4 qwer. Angle Body Piston Valves 2/2 SERIES. Air Operated. Auxiliary Piloted. Bronze or 316L Stainless Steel Bodies 1/2" to 2" NPT

NZQA Expiring unit standard version 3 Page 1 of 6

NEMA LAY-IN WIREWAY

*TM &P INTRODUCTION PAGE 1-1

Silver Plus. Manual Guns. Airless. Features and Benefits. Typical Applications. Typical Fluids Handled

CONVENIENCE METAL FABRICATION ABRASIVES VENDING SOLUTIONS CORNER STORE RIGHT ON THE FLOOR

VAN WERT COUNTY HOSPITAL. Policy/Procedure: Interdepartmental No.: N Issue Date: 6-90 By: Nursing No. of Pages: 9

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

Audio. Distribution. Network ADN C1/ADN D1. Quick guide

EZTest Incubator OPERATION MANUAL. 10 Evergreen Drive Bozeman, MT USA (303) Model

PRICE LIST MOTORS & FANS

j. Billing procedure k. Periodical Inspections Page 1

CONVENIENCE CORNER STORE RIGHT ON THE FLOOR

TECHNICAL MANUAL OPERATOR, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

MVCC A&P Test Preparation Course Contacts and Study Material

1510 Self-Contained Biological Indicator Incubator OPERATION MANUAL

Automotive unit test specification breakdown

ENTERPRISE with people in mind

Product Introduction. Specification Sheet. Certificates. Application. Features. Street Light

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1041 ASPHALT CONCRETE QUALITY ASSURANCE PROGRAM ADMINISTRATION.

OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING LASER: M83 (NSN ) FOR

www MK-Electronic de 5 Parts List 8. Xerographic PL 8.1 Xerographic (1 of 2) PL 8.2 Xerographic (2 of 2)

Easylink to Liebert Sitelink Module

L1-CHE-SPE-305 SIGNAL IDENTIFICATION AND GENERAL INFORMATION

Sub : Guidelines for Procurement from Micro and Small Enterprises (MSEs)

ARMY TM AIR FORCE TO-35C NAVY NAVFAC P

Caution! triangles are used to warn of situations that demand extra care and attention.

13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Electrosurgery. For theatre nurses. Basic proficiency requirements for the safe use of electrosurgery

F60CET 06 (6C52) 1E6C5-280E /3/31 NEWS NO. DATE COMMENT PE0-OM March,2,2009 MOD:FIG.24 PTT(6C D) P/No.

Chapter 6 MANHATTAN COLLEGE

Kimberly Shea, Administrator, Technical Projects. SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

What will be covered in this NAEP workshop?

Lightweight Multi-Role Missile Integrated SAFU & Lethal Payload L.J.Turner - Thales LAND DEFENCE

Metal mesh protection

MULTMED MODULAR MEDICAL BED LIGHT

MMO

SECTION NURSE CALL/CODE BLUE SYSTEM (JERON)

Eleganza 5. art of nursing

EASYLINE SYSTEM OVERVIEW

Bed Rail Provision Guidance for Assessment and Provision. Clinical & Prescriber Support Special Interest Group

ESSENTIAL SAFETY RESOURCES

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

COMPANY PROFILE. Company Profile YOUR STRATEGIC PARTNER IN PRECISION ENGINEERING

smart technologies Neonatal incubator from standard to intensive care

BUILDING OFFICIALS ASSOCIATION OF FLORIDA CROSS TRAINING PROGRAM SYLLABUS. Electrical Plans Examiner Training Program

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST GENERATOR SET, TACTICAL QUIET

Transcription:

Rotonivo Series RN 3000 RN 4000 RN 6000 Instruction manual 010516 1

UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction manual: Types RN 3001 / 3002 / 3003 / 3004 / 3005 RN 4001 RN 6001 / 6002 / 6003 / 6004 Approvals CE /TR-CU ATEX 1/2D / IEC-Ex t IIIC 2

Table of Contents Safety / Warning Notes Page 4 Fields of application Page 4 Technical Data Page 5 Application Page 19 Installation Page 26 Electrical connection Page 29 Switching logic Page 34 Settings Page 38 Maintenance Page 38 ATEX / IEC-Ex - Notes Page 39 3

Safety /warning notes Installation, maintenance and commissioning may be accomplished only by qualified technical personnel. For terminal connection of the device, the local regulations or VDE 0100 (Regulations of German electrotechnical Engineers) must be observed. Switch off the supply voltage before opening the device. All field wirings must have insulation suitable for at least 250V AC. The temperature rating must be at least 90 C (194 F). In the case of handling by untrained personnel or handling malpractice, the safety of the device cannot be guaranteed. Fields of application Level limit switch for point level limit detection in bulk materials. Applicable as full -, demand - and empty detector. 4

Technical Data Housing RN 3000 82mm (3.22 ) 97mm (3.82 ) 36mm (1.41 ) 104mm (4.1") RN 4000 RN 6000 Ø120mm (Ø 4.72 ) 135mm (5.31 ) 125mm (4.92 ) 5

Temperature extended shaft RN 3001 RN 3002 RN 3004 RN 6001 RN 6002 RN 6004 Ø 33mm (Ø 1.3 ) A Dimension A A = 0mm (0 ) A = 200mm (7.87 ) A = 300mm (11.8 ) A = 400mm (15.7 ) C 80 C (176 F) 150/250 C (302/482 F) 350 C (662 F) 600 C (1112 F) 6

Temperature extended shaft RN 3003 RN 6003 Ø55/60mm (Ø2.16/2.36 ) A Dimension A A = 10mm (0.39 ) A = 75mm (2.95 ) A = 210mm (8.26 ) C 80 C (176 F) 80 C (176 F) 150/250 C (302/482 F) 0,8bar (11.6psi) 5/10bar (73/145psi) 0,8/5/10bar (11.6/73/145psi) 7

Extension RN 3001 RN 4001 RN 6001 Material according to order data Ø10mm (Ø0.39 ) L Material according to order data L = 70mm 1500mm (2.75 59 ) 1.4301 (304) / 1.4305 (303) Ø8mm (Ø0.31 ) 2.000mm (78.7 ) 1.4301 (304) / 1.4305 (303) 300... 1.000mm (11.8... 39.37 ) Rope extension Pendulum shaft 8

Extension RN 3002 RN 6002 Material according to order data Ø33mm (Ø1.3 ) L Ø10mm (Ø0.39 ) Material according to order data L = 250mm 4000mm (9.84 158 ) 9

Extension RN 3002-Rope RN 6002-Rope Material according to order data Ø8mm (Ø0.31 ) Ø10mm (Ø0.39 ) L = 500mm 10.000mm (19.68...393.7 ) Ø10mm (Ø0.39 ) Ø8mm (Ø0.31 ) L = 1.000mm 10.000mm (39.37...393.7 ) max. 4 kn max. 28 kn 10

Extension RN 3003 RN 6003 Material according to order data L Ø55/60mm (Ø2,16/2.36 ) 1.4305 (303) B A L = 125mm 300mm (4.92...11.81 ) A 139mm (5.47") 187mm (7.28") B 50mm (1.97") 98mm (3.9") 11

Extension RN 3004 RN 6004 Material according to order data Ø33mm (Ø1.3 ) Ø10mm (Ø0.39 ) L Material according to order data RN 3005 L = 150mm 600mm (5.9...23.6 ) 97x82mm (3.82x3.22 ) Material according to order data 90mm (3.5 ) 87mm (3.43 ) 1.4305 (303) 1.4301 (304) 200mm (7.87 ) 12

Measuring vane Rectangular vane 1.4301 (304) / 1.4404 (316L) A B 50mm (1.97 ) 98mm (3.86 ) 50mm (1.97 ) 150mm (5.9 ) 50mm (1.97 ) 250mm (9.84 ) 98mm (3.86 ) 98mm (3.86 ) 98mm (3.86 ) 150mm (5.9 ) 98mm (3.86 ) 250mm (9.84 ) Notched 1.4301 (304) / 1.4404 (316L) 13

Measuring vane Boot shaped vane 1.4301 (304)/ 1.4404 (316L) 1.4301 (304)/ 1.4404 (316L) 40mm (1.57 ) 35mm (1.38 ) 98mm (3.86 ) 106mm (4.17 ) 1.4301 (304)/ 1.4404 (316L) 28mm (1.1 ) 1.4301 (304)/ 1.4404 (316L) 26mm (1.02 ) 98mm (3.86 ) 77mm (3.03 ) 14

Measuring vane Hinged vane double side 1.4301 (304)/ 1.4404 (316L) Hinged vane single side 1.4301 (304)/ 1.4404 (316L) b=28mm (1.1") / 37mm (1.46") 15

Measuring vane Rubber vane Universal vane Plastic PP 16

C T amb RN 3000 T process (1,2) (1) RN 4000 T amb 60 C (140 F) -40 C (-40 F) -20 C (-4 F) 80 C (176 F) T process (1,2) -20 C (-4 F) -40 C (-40 F) (1) See type plate (2) with internal heating 17

RN 6000 (1,2) (1) (1) See type plate (2) with internal heating RN 3000 / RN 6000 RN 4000 min. -0,9bar (-13.1psi) (1) max. 0,8 / 5 / 10bar (11.6 / 73 / 145psi) min. -0,9bar (-13.1psi) max. 0,8bar (11.6psi) (1) See type plate 18

Application RN 3001 RN 4001 RN 6001 L L max. 1 2 3 4 5 600mm (15.24 ) 300mm (7.62 ) 150mm (5.9 ) 150mm (5.9 ) (1) (1) Protective angle (canopy) in case of high mechanical load 19

RN 3001 RN 4001 RN 6001 max. 400N max.1,5kn Pendulum shaft Rope extension 20

RN 3002 RN 6002 max. 10 (2) L (1) 1 2 L max. 3.000mm (118.1 ) 4000mm (158 ) (1) (2) Mechanical support Incline installation with option 32 (bearing at tube end) 21

RN 3002-Rope RN 6002-Rope L (1) (1) 1 2 L min. 500mm (19.68 ) max. 10.000mm (394 ) (1) Max. pulling force 4kN / 28kN, see type plate 22

RN 3003 RN 6003 L L max. 300mm (11.81 ) 23

RN 3004 RN 6004 L L max. 300mm (11.81 ) 24

RN 3005 Loading bellow 25

Assembly Example: Insertion of the hinged vane in a long socket Fixing / Sealing Spring Teflon gasket or flat gasket Sealing 26

Fixing EHEDG 100Nm (1) (2) (3) (4) (1) (2) (3) (4) Certified welding sleeve prescribed Metal-metal support gap-free Teflon tape Welding (observe hygiene guidelines) 27

Alignment Ingress protection IP 66 Option: Weather protection cover for Ex only approved for Zone 22 28

Electrical connection RN 3000 RN 4000 8 7 6 5 1 1 2 PE RN 6000 8 9 10 7 6 5 4 1 2 Terminals according to selected version 29

Electrical connection - RN 3000 / RN 4000 Version - AC - DC - Universal voltage max. 1,5mm² (AWG16) max. 10A HBC 250V T/F (3) (2) max. 250V AC, 2A, 500VA (cosj = 1) max. 300V DC, 2A, 60W L N + - (1) PE Version (4) AC DC Universal voltage 24/48/115/230V ±10% (5), 50/60Hz max. 4VA 24V DC ±15% (5), max. 2,5W 24V DC ±15% (5), max. 4W 22...230V ±10% (5), 50/60Hz, max. 10VA (1) (2) (3) (4) (5) Supply Signal output Alarm outout see typeplate including 10% from EN 61010 30

Electrical connection - RN 3000 / RN 4000 Version - PNP + - PE 24V DC ±15% (1) max. 0,6A max. 0,4A (1) including 10% from EN 61010 31

Electrical connection - RN 6000 Version - AC - DC max. 4mm² (AWG12 max. 10A HBC 250V T/F (2) max. 250V AC, 5A (5) max. 30V DC, 4A (5) L N + - (1) PE Version (4) AC DC 24/48/115/230V ±10% (4), 50/60Hz max. 4VA 24V DC ±15% (4), max. 2,5W (1) (2) (3) (4) (5) Supply Signal output see typeplate including 10% from EN 61010 not inductive 32

Electrical connection - RN 6000 Version - Universal voltage max. 4mm² (AWG12 max. 10A HBC 250V T/F max. 10A HBC 250V T/F (2) (3) max. 250V AC, 5A (5) max. 30V DC, 4A (5) L N + - (1) PE 24V DC ±15% (4), max. 2,5W 22...230V ±10% (4) 50/60Hz, max. 10VA (1) (2) (3) (4) (5) Supply Signal output Alarm outout including 10% from EN 61010 not inductive 33

Switching logic Signal output without FSL/FSH 7 6 5 8 9 10 7 6 5 8 9 10 34

Signal output with FSL/FSH RN 3000/4000: FSL FSH (1) (2) RN 6000: FSL FSH (2) (1) (1) (2) yellow green 35

Signal output delay RN 3000 RN 4000 RN 6000 36

Alarm output Version with rotation control No error RN 3000/4000: RN 6000: 8 7 6 5 7 6 5 4 Error 8 7 6 5 7 6 5 4 red 37

Setting Setting of the spring force RN 3000 RN 4000 RN 6000 (1) (2) (3) (4) (1) (2) (3) (4) Spring light: central: strong: for light material universal for very sticky material Maintenance Normally not necessary 38

ATEX II 1/2D + IEC-Ex t IIIC Da/Db Notes Permitted relative pressure Zone borders -0,2...+0,1bar (-2.9 +1.45psi) RN 3000 RN 4000 RN 6000 (1) 2D (2) Db (3) 21 (1) 1D (2) Da (3) 20 (1) Category ATEX (2) EPL (IEC-Ex) (3) Zone 39

Ambient temperature Zone 21 Zone 20 30 C (86 F) 50 C (122 F) 40 C (104 F) 60 C (140 F) 50 C (122 F) 70 C (158 F) 50 C (122 F)/ 60 C (140 F) 50 C (122 F)/ 60 C (140 F) 90 C (194 F) 120 C (248 F) (1) 100 C (212 F) 120 C (248 F) (1) 110 C (230 F) 120 C (248 F) (1) 80 C (176 F) 120 C (248 F) 90 C (194 F) 100 C (212 F) 110 C (230 F) 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) 160 C (320 F) 170 C (338 F) 180 C (356 F) 190 C (374 F) 200 C (392 F) 210 C (410 F) 220 C (428 F) 230 C (446 F) 240 C (464 F) 250 C (482 F) Max. surface temperature 120 C (248 F) 120 C (248 F) 120 C (248 F) 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) 160 C (320 F) 170 C (338 F) 180 C (356 F) 190 C (374 F) 200 C (392 F) 210 C (410 F) 220 C (428 F) 230 C (446 F) 240 C (464 F) 250 C (482 F) T Zone 21 Zone 20 Zone 21 Zone 20 (1) When using the electronic "universal voltage". 40

Installation RN 3000 RN 4000 RN 6000 (1) (1) (2) (2) (1) A mech. pull relief must be provided (2) Connect to plant ground 41

ATEX / IEC-Ex: Further Remarks For installation and field wiring the respectively valid installation regulations of the respective country must be observed. Commissioning only with closed lid. Do not remove the lid (cover) while circuits are alive. Before opening the lid take care, that no dust deposits or whirlings are present. The installation has to be done in a way, that mechanical friction or impact does not cause sparks between the aluminium enclosure and steel. For process temperatures over 230 C the delivered sealings of the flanges and of the sliding sleeve must be checked regulary for good order and condition. Cable Glands: Installation according to the regulations of the country, where the product is installed. Not used entries have to be closed with blanking elements certified for this purpose. Where applicable the factory provided parts must be used. A strain relief must be provided for the field wiring cables, when the device is installed with the factory provided cable glands. The diameter of the field wiring cable must match to the clamping range of the cable clamp. If other than the factory provided parts are used, following must be ensured: The parts must have an approval adequate to the approval of the level sensor (certificate and type of protection). The approved temperature range must be from the min. ambient temperature of the level sensor to the max. ambient temperature of the level sensor increased by 10Kelvin. The parts must be mounted according to the instructions of the supplier. 42