Airborne Infectious Disease:

Similar documents
Isolation Precaution (Part 2) Protective Environment (PE) Room. Combined AII/PE Rooms. Contact Isolation 5/22/2017

PRESENTORS Cyndi McCullough Andrew Yosten

Formal Interpretations Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014 edition

July 10, reduce the risk of staff or patient airborne exposure to communicable diseases during surgical procedures (See Appendix A) and

Hospital Construction, Renovation, and Demolition

Facility Tuberculosis (TB) Risk Assessment for Correctional Facilities

Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY. 1 WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM August 2010 eere.energy.

HEALTHCARE GUIDELINES AND STANDARDS

Tuberculosis (TB) risk assessment worksheet

Replaces: 08/11/16. Formulated: 1/2000 TRANSMISSION-BASED PRECAUTIONS

Infection Control Risk Assessment (ICRA): Construction Trades Best Practices Awareness Training

Providing Quality Equipment and Services for Specialized Mechanical Air Systems. Serving Kentucky and Southern Indiana for over 70 years

Objectives. Clinic Scenario. Addressing TB in Our Communities November 19, 2015 Curry International Tuberculosis Center

Procedure for Control of Aspergillosis During Construction/Renovation Activities. Procedure No. 209

Risk Assessment for the TB Laboratory

RESEARCH LABORATORIES CONDUCTING HIV/HBV RESEARCH AND PRODUCTION

Guidelines for Operating the Ventilation System in Negative Pressure Isolation Rooms

Pharmacy Sterile Compounding Areas

Office of Emergency Preparedness

Standard EC Elements of Performance for EC The hospital manages fire risks.

WARD ISOLATION SUITE BASIC CONCEPTS and RESEARCH PROGRAMME. Malcolm Thomas Consulting Engineer March 2006

INFECTION C ONTROL CONTROL CONTROL EDUCATION PROGRAM

OH&ESD. Technical Data Bulletin

Building a tutorial on safe use of personal protective equipment

A PRINTED copy of this guideline may not be the most recent version. The OFFICIAL version is located on IHNET at the Policies & Procedures Home Page

The Joint Commission and Facility Design: A Partnership for Patient Safety and Quality Care

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Frequently Asked Questions about TB Protocols at Duke Hospital and Clinics ( Revision)

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Compounded Sterile Preparations Pharmacy Content Outline May 2018

EQUIPMENT MANAGEMENT MEDICAL EQUIPMENT: EC , EC UTILITY SYSTEMS: EC , EC

ISOLATION TABLE OF CONTENTS STANDARD PRECAUTIONS... 2 CONTACT PRECAUTIONS... 4 DROPLET PRECAUTIONS... 6 ISOLATION PROCEDURES... 7

Access to the laboratory is restricted when work is being conducted; and

Standard Precautions must always be used in addition to Transmission Based Precautions.

Observations will be made of the storage. knowledge of the hazardous materials. labeling the container to the use of. containers (which may range from

DISEASE TRANSMISSION PRECAUTIONS AND PERSONAL PROTECTIVE EQUIPMENT (PPE)

Part D Infection Control

Evolution of a Team-Run BSL-3 Facility Maintenance Program

NORTHERN ZONE SAN MATEO COUNTY FIRE AGENCIES (Brisbane, Colma, Daly City, Pacifica and San Bruno) EMS - POLICY MANUAL

Infection Control in Healthcare. Facilities

Planning and Designing an Isolation Facility in Hospitals: Need of the Hour

SANTA BARBARA SHERIFF-CORONER S BUREAU Still an Unhealthy Environment

Duke Hospital and Clinics Hazard Specific Respiratory Protection Policy

Infection Control and Prevention On-site Review Tool Hospitals

Of Critical Importance: Infection Prevention Strategies for Environmental Management of the CSSD. Study Points

SAMPLE: Environmental Rounds and Safety Assessment Tool

April 10, 2018 York Chan, CHFM, CHC, SASHE

Copyright 2007 Fiberlock Technologies

MODEL PLAN. (Name of School) INDOOR ENVIRONMENTAL QUALITY MANAGEMENT PLAN

Infection Prevention and Control for Phlebotomy

Tuberculosis Infection Control

Recommended Physical Plant Improvements to Existing Nursing Homes for Disaster Preparedness. Report to the Governor and to the Legislature

Infection Prevention Control Team

Assessment Tool Environmental Services

NYC DOHMH Guidance Document for Development of Protocols for Management of Patients Presenting to Hospital Emergency Departments and Clinics with

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157

Indoor Environmental Quality Management Plan

PRECAUTIONS IN INFECTION CONTROL

Infection Prevention and Control

Formal Interpretations Guidelines for Design and Construction of Health Care Facilities, 2010 edition

Occupational safety in laboratories

Safety and Health Movement: An Overview p. 1 Developments Before the Industrial Revolution p. 2 Milestones in the Safety Movement p.

GENERAL HOSPITAL ORIENTATION Revised: January 2013 EE Intl Hosp Ort

Scaling Up TB Infection Control Infrastructure Considerations

By now, everyone should be very familiar with the H&S Guidance contained in WPN For that reason, we won t review the entire WPN 17-7, but just

Correctional Tuberculosis Screening Plan Instructions

REGULATORY & ACCREDITING AGENCIES

AORN Recommended Practices for Environmental Cleaning (2014) APIC Chapter San Diego and Imperial County

The Healthcare Environment Challenges and Update

University of North Dakota Facilities Department Respiratory Protection Program. Table of Contents. 1.0 Introduction Purpose...

Briefing for providers in relation to service development for inpatient service for Airborne High Consequence Infectious Diseases.

Regulations that Govern the Disposal of Medical Waste

WHO policy on TB infection control in health care facilities, congregate settings and households.

Comply with infection control policies and procedures in health work

Health Building Note Supplement 1 Isolation facilities for infectious patients in acute settings

SUBCHAPTER 31. MANDATORY PHYSICAL ENVIRONMENT

[Type here] RESPIRATORY PROTECTION PROGRAM

SECTION 11.4 VANCOMYCIN RESISTANT ENTERCOCCUS (VRE)

Infection Prevention Implementation and adherence to infection prevention practices are the keys to preventing the transmission of infectious diseases

Patient Safety Course Descriptions

Infection prevention & control

SHERIFF-CORONER S BUREAU The Manner of Death A Final Diagnosis SUMMARY

Subchapter 7. General Industry Safety Orders Group 16. Control of Hazardous Substances Article 109. Hazardous Substances and Processes

Model Indoor Air Quality Management Plan

Guidelines on Infection Prevention and Control for Cork Kerry Community Healthcare 06: Transmission Based Precautions

STANDARDS FOR INFECTION CONTROL

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control

Joint ASHRAE Hong Kong/Macao Chapters Half-Day Technical Seminar 2018 on High Performing Healthcare HVAC Systems

Emergency Planning: The Galveston National Laboratory. Joan E. Nichols PhD University of Texas Medical Branch Associate Director GNL Galveston, Texas

IC CONTACT and CONTACT PLUS PRECAUTIONS REV. JULY 2017

DEPARTMENTAL POLICY. Northwestern Memorial Hospital

Face Masks and Respirators: Protection Factors, Selection, Fit Testing, and Respirator Demonstrations

Contamination control: part 2 a vet nurse s critical role

INFECTION PREVENTION & CONTROL, INCLUDING PROCESSING ITEMS FOR REUSE, IN GENERAL PRACTICE

TB in the Correctional Setting Florence, Arizona October 7, 2014

Infection Control Manual. Table of Contents

Critical Care Design The Good, The Bad and The Alternatives Karen Iverson, MHSc CIC A Webber Training Teleclass

Code of Practice Controlling access to hazardous or sensitive areas

Urinalysis and Body Fluids

Ebola Virus Disease (EVD)

Transcription:

Airborne Infectious Disease: Best Practices for Industrial for Ventilation Applications Management The latest guidance and advice for emerging infectious disease preparedness and control. Photograph provided by HDR Architecture, Inc. all rights reserved. Photography by Jeffrey Jacobs, Jeffrey Jacobs Architectural Photography, Inc. Control measures for airborne infectious diseases are invaluable in health-care facilities that treat patients with these afflictions. These hospitals may also need to treat immunocompromised patients, such as solid organ transplant recipients, or those being treated for blood cancers. Verification of these special ventilation conditions requires a thorough understanding of the design and maintenance of the requisite specifications in order to provide the appropriate ventilation parameters for protective environment patient rooms (See Table 1). VENTILATION REQUIREMENTS The initial cost of ventilation equipment versus future maintenance requirements is just one factor of what cost should be considered for hospital facility management. Sustainability of health-care buildings is maintaining the building to the specification to which it was designed. Today s patient care challenges include emerging infectious diseases, some of which are airborne. Some of these diseases, such as aspergillosis, only affect patient populations, but others, such as tuberculosis, prey on heath-care workers, as well. The management of the mechanical systems in healthcare becomes critical for the safe environment of care. Issues relating to the building envelope are critical to proper infection control. For example, maintaining the window seal and the management of the pressure relationships of a building are both essential in the management of infectious diseases. Construction and maintenance of ventilation systems should be designed to provide consistent air exchanges for dilution ventilation and the exhaust of airborne hazards. The pressure relationships between inside and outside the building or between different interior spaces is needed to mitigate the migration of airborne hazards. Filtration with greater than 90 percent efficiency (>MERV14) will physically remove the airborne particles at greater than 99 percent efficiency if the particles are greater than 1.0 µm in diameter. Ultraviolet (UV) light is an air disinfectant, By ANDREW J. STREIFEL Hospital Environment Specialist. Minneapolis, MN. A member of HPAC Engineering s Editorial Advisory Board, Andrew J. Streifel, MPH, is a hospital-environment specialist for the University of Minnesota. Over the past 25 years, he has assisted more than 300 hospitals worldwide with environmental infection-control issues pertaining to air and water. He has published numerous articles in HPAC Engineering, including Health-Care IAQ: Guidance for Infection Control in October, 2000, and Assessment of Health Risks Related to Construction, in February 2002. He can be reached at strei001@umn.edu. HPAC Engineering September 2003 97

A I R B O R N E I N F E C T I O N which may have application as supplemental engineering controls under certain conditions. However, suggestive clinical or epidemiological studies do not totally support the use of UV in healthcare facilities, therefore the recommendation is marginal as a category II rating by the Centers for Disease Control and Prevention (CDC) in its recent Guidelines on Environmental Infection Control. 1 Such options must be carefully considered for the long term safety in healthcare facilities. Source control is the essence of managing infections. Therefore the principal of source management as it pertains to the potential sources of the infectious agent must be understood and should be applied as an analysis for Ventilation parameters Airborne infection Protective environment Air changes per hour More than 12 More than 12 Filtration Supply Return Toilet Supply versus exhaust offset Air-flow direction Pressure differential Minimum room leakage 90% dust spot 99.97% at 0.3 m 100% exhaust More than 125 cfm Into room Over 0.01-in WG Less than 0.5 sq ft. hazard reduction. Another relatively new consideration is bioterrorism. A hospital that protects its 99.97% at 0.3 m Back through filter or 100% exhaust 100% exhaust More than 125 cfm Out of room Over 0.01-in. WG Less than 0.5 sq ft. TABLE 1. Commissioning guidelines for special-ventilation rooms in health-care settings. patients from common biological agents should be able to protect patients from bioterror activity. Two New Hospital Ventilation Guidelines Two recent guidelines have been made available to help hospitals manage ventilation for infectious disease control. The Centers for Disease Control and Prevention (CDC) published Guidelines for Environmental Infection Control in Health- Care Facilities. 1 These guidelines provide the recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). The contents of this document include the rationale for recommendations and rating for issues relating to air, water, environmental services, environmental sampling, laundry and bedding, animals in healthcare facilities and regulated medical wastes. The document is quite specific in the performance measurements that need to be established to assure ventilation control of airborne infectious diseases. It emphasizes the risks involved with immunocompromised patients, a diverse patient population that is growing rapidly. Because of this fact,the CDC felt that the guidelines should include recommendations for cleaning, maintenance, water quality and ventilation. The documents discusses the need to provide immediate response to water intrusion to avoid mold growth. Such contamination can lead to infection in immunocompromised patients. The CDC Environmental Infection Control is free for download from www.cdc.gov. This document took three- plus years to compile due to the massive volume of information that needed to be gathered and verified. At the same time, the ASHRAE SP-91 team was compiling a the "HVAC Design Manual for Hospitals & Clinics" which is now available for purchase from ASHRAE (www.ashrae.org). The manual provides best practice design considerations for operators of mechanical systems. The intent of the book was to gather experienced writers and reviewers to compile the design considerations for a variety of operational considerations Topics include essential terminology, HVAC design criteria, design for existing facilities, cooling and heating plants, controls for mechanical systems, life safety considerations, room design, operation and maintenance, commissioning guidelines, and energy conservation. This book provides one of the most comprehensive overviews of mechanical system management in a health-care facility ever published. With these two documents, a building manager will have some of the most timely, state-of-the-art information available to manage the ever-changing climate in dynamic health-care world. The challenges of building management are formidable: disaster planning, biodefense, and infectious disease management. 98 September 2003r HPAC Engineering

A I R B O R N E I N F E C T I O N INFECTION CONTROL GUIDELINES Pressure should be the key factor for ventilation-control of infectious agents However, pressure management in health care is focused on fire and smoke control. Infectious disease management has often ignored pressure management especially as it pertains to consistent airflow. Too often, fan belts slip, windows are left open or doors not closed all of which prevent consistent pressure management. When such breeches occur, it means that pressure management for airborne infectious diseases will not work. For example, a renovation job several years ago at a patient-care hospital required that walls be opened for the construction of an elevator. In this case, one of the only control measures was to close the outside doors at the construction site, but not even this was done. As a result, there was a cluster of infections at a major hospital. 2 GENERAL ADVICE In order to achieve the desired pressure relationships in rooms, common mistakes should be avoided. Air volume offsets between supply and exhaust/return are designed too low to achieve the recommended pressure relationship of greater than 0.01 in. wg for airborne infection isolation and protective environments. The offset of supply versus exhaust/return air volume should be greater than 125cfm in a standard 1,200 sq ft room. The rooms should be designed with that offset and the room leakage points should be sealed to less than 0.5 sq ft total leakage area. Once the room ventilation is functioning as designed, the monitoring of the rooms can be activated, according to the Architectural Institute of America guidelines. 3 According to this guide, special ventilation rooms for isolating airborne infectious patients (AII) and protecting patients should have a permanently installed visual monitoring system of the airflow direction. These monitoring systems can be mechanical or electronic but do not need to be alarmed. If alarms are installed, allowances should be made to prevent nuisance alarms of the monitoring system. The rooms,if properly designed with the appropriate air volume offset should not have nuisance alarms, but allowances for a time delay before alarm activation is necessary to allow for the opening of doors in the special ventilation rooms. Room leakage is an important factor because the offset between supply and exhaust/return will if the leakage area is too large decrease the pressure due to inflow or outflow of air to paths of air with less resistance, such as through improperly sealed windows.. Excessive infiltration would not allow for adequate depressurization of the airborne infectionisolation room for isolating patients in that room who may have active tuberculosis. With other conditions, such as during construction, risk assessments for excavation or demolition next to a hospital with immunocompromised patients may be at risk due to the pressurization of the critical care buildings. For example, if Circle 160 100 September 2003 HPAC Engineering

A I R B O R N E I N F E C T I O N more air is exhausted in the building than is supplied, a pressure imbalance will occur. This will happen in high rise ( greater than 6 stories) building because of the stack effect when warm air rises in a building. Such conditions can bring air into the critical-care hospital that does not get filtered or dehumidified by the air handling system. Such conditions can create condensation water on cool surfaces providing ideal mold growth conditions. The depressurization of the building can also allow unfiltered air into the building, which probably contains Aspergillous spores, which are opportunistic pathogens to certain patients. When pressure management is needed, operable windows, open doors and building connections can cause building pressure problems. During a recent evaluation, the source of irritating particles in patient-care areas was from a boiler room, due to a building ventilation imbalance. That building required an immediate air balance analysis to correct what was found to be an extreme building pressure imbalance. The hospital on the day of that evaluation was depressurized to 6 Pascal s (0.025-in. wg), which represents air velocity into the building through openings in excess of 500 linear ft per min. Maintenance priorities are always an issue for any system, but an absolute must for infection control management. 4 In some emergency rooms, a single switch was designed to exhaust the ER area to provide for immediate isolation of the ventilation in waiting areas and rooms. Such switches are not recommended for the all-purpose isolation rooms,such areas would allow for switching from protective to airborne infections rooms. The AIA does not recommend this practice due to the sophisticated controls needed and the number of nonfunctioning rooms which were discovered when tested. In some hospital ERs, it is possible to create airborne-infection bays to provide the appropriate ventila- tion airflow by simply closing the door. According to the National Bioterrorism Hospital Preparedness Program 2003, it is desirable for the hospital to have at least one airborne infection room per hospital participating in the program. 5 The facility selected should have the capability to treat 10 adult and pediatric patients. With such a request, it will be necessary for selected hospitals to have negativepressure environments which include isolation wards. Many hospitals have isolation rooms due to the resurgence of tuberculosis in the early 1990s. These rooms should meet the AII room criteria, which is listed above. MONITORING Monitoring devices are intended to maintain awareness changes that might affect critical features of the ventilation system. Such critical areas include AII and protective environments (PE). These rooms are required to be monitored. The use of smoke sticks is recommended as a visual check, but a mechanical monitoring systems, such as flutter strip or ball in a tube system, are capable of demonstrating appropriate airflow direction when the door is closed.testing of such visual equipment can be accomplished simply by opening and closing the door of the room. Such visual systems will show that the ball moves across the opening during the door movement just like smoke movement when the door is closed. Likewise, electronic systems should zero under the same test method and digitally demonstrate zero when to door is open or a level of pressure greater than 2.5 Pascals (0.01-in. wg) when the door is closed. Some electronic systems can plug with lint after some time, therefore they should be routinely checked for accuracy with another calibrated pressure-testing device. The AII rooms should be checked at least monthly and if infectious patients are housed in the AII rooms they should be checked daily. A visual monitor would be assuring because of the simple test validating movement of a flutter strip or ball. Maintenance cost must be included if the utilization of electronic monitoring devices is considered. 102 Circle 207 September 2003 HPAC Engineering

A I R B O R N E I N F E C T I O N USING EXISTING ISOLATION SYSTEMS As previously stated there should be a cost effective way to establish zones for airborne isolation of many patients in one place in a hospital. With modern hospital ventilation units, we need to look to existing systems to provide such management of multiple cases of infectious patients. There are smoke zones already mandated to manage fire and smoke within the health-care structure. These zones are set up to evacuate the smoke if fires occur. The zone is fire stopped to prevent smoke movement between zones. These barriers are air tight enough to allow for potential isolation of many beds within the hospital. The individual rooms within that zone might not be capable of being depressurized but with closed doors and zone exhaust capability, this space could be effectively isolated from the other parts of the healthcare facility Such zones exist and are tested for fire management routinely. These natural zones are also used to isolate construction projects in order to manage the aerosols generated by construction and renovation. We do this by using the balance dampers to help depressurize the area by reducing the supply air. The complete exhaust of that zone becomes a challenge but can be accomplished. SAFE STORAGE OF PROTECTIVE GEAR Providing areas for the storage of infectious-disease personal protective equipment (PPE) is important. These storage areas will be required due to potential super shedder concerns for environmental contamination during the recent SARS outbbreak. The mode of transmission of SARS is not certain especially whether the SARS virus is airborne or droplet/contact spread. Emerging infectious diseases, like SARS, will require thoughtful, cost-effective preparedness for the environment. EMERGENCY PREP AREAS ER triage and waiting areas are needed to quickly identify patient problems as they arrive in the hospital. Such areas should have isolation capability for chemical decontamination or infectious disease control. The triage indication of airborne infectious disease should dictate the immediate isolation of that patient in an airborne-isolation condition with appropriate ventilation parameters to contain any release of infectious droplet nuclei. Many ERs are equipped to handle one or two such patients. But what happens if many patients show up with suspicious symptoms? Enlightened architects are providing ERs with waiting areas that can be separated with simple room dividers having exhaust ducts on one side of the divider and a supply air duct on the other. Larger numbers of contaminated patients may be housed on the side with the exhaust with airflow into that area exhausting to the outside. Some of these ERs have a switch on the wall to create a complete depressurization of the ER if Circle 195 Circle 193 HPAC Engineering September 2003 103

AIRBORNE INFECTION needed. CONCLUSION Anticipation of the problems associated with infection control should focus on the existing issues for controlling airborne spread diseases such as aspergillosis and tuberculosis. These are two examples of the problems which realistically could plague a facility if they are not prepared. In preparation the principals of infectious disease management must be focused on the condition of the mechanical systems and where the risk is expected. The preparation must consider what can be accomplished for minimizing the risk to patients and employees. The National Bioterrorism Hospital Preparedness Program is developing the cooperative agreement with states to develop a plan for management of terrorist associated disease. The current exposure problems with know infectious agents if handled with basic of principals of ventilation management will help to prepare for the unthinkable. REFERENCES 1) CDC (June 6, 2003). Morbidity and Mortality Weekly Report. Centers for Disease Control and Prevention, Atlanta, Ga. Vol 52/RR-10. 2)Transplant Infectious Diseases (1999). Vol 2:22-28.Blackwell Publishing Inc.,Malden, MA 02148 3 )AIA (2001). Guidelines for Design and Construction of Hospitals and Healthcare Facilities 2001 American Institute of Architects. Washington, DC. 4) Streifel, A. (2000). APIC Text of Infection and Epidemiology, Association for Professionals in Infection Control and Epidemiolgoy Inc, Washington, DC. 5. HRSA (2003). National Bioterrorism Hospital Preparedness Program 2003, The Health Resources and Services Administration, U.S. Dept. of Health and Human Services. For HPAC Engineering feature articles dating back to January 1992, visit www.hpac.com. 104 September 2003 HPAC Engineering