COMMUNICAT COMMUNICA ION SYSTEM HCC-07.2 TION SYSTEM HCC-07.2

Similar documents
NCS Nurse Call System. Bridging Communications & Care Delivery Services

Telligence Nurse Call Communication System. Total solutions for patient-staff communications

TELLIGENCE. Ascom. Nurse Call System. The complete patient-staff communication solution. Ascom

Allworx Reach and Reach Link

Eleganza 3XC. Designed for ICU

GIVES YOU A CHOICE OF NURSE CALL.

CAP IP. ip intercom REFUGE CALL POINTS IP NETWORK SALES DEPARTMENT SECURITY DISPATCH SMARTPHONE SUPERVISION IP MAYLIS RANGE

MediCom. MediCom AUSTCO. State of the art Hospital Emergency Call System. The very best in nurse call and. care management solutions

Integrated Nurse Call Solutions

Thopaz. Einführung. Welcome to the age of digital thoracic drainage therapy! «What I want... is a safe and efficient drainage therapy»

Full IP. nursecall and notification

Nurse Call System. A Voice over IP Based Solution for Streamlined Communication, Alerting and Workflow

NURSE CALLING SYSTEM

Introducing a new class of fire detection

Simply Intuitive. The Hill-Rom Advanta 2 Bed

smart technologies Neonatal incubator from standard to intensive care

smart technologies Neonatal incubator from standard to intensive care

Wireless Nurse Call System Designed with you in mind

Clinical Pendants. starkstrom. Enhancing Safety at the Bedside. Powering Healthcare. a Progility company

(800) Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

MEDICAL ALERT SETUP GUIDE

Greening the Blue Reducing UN s Climate Footprint with ICT. Niclas Svenningsen Head, Sustainable United nations UNEP

Protection and Convenience For You and Your Patient

City of Waterbury Safety & Security Assessment

The provision of FirstNet s NeoVoice access service is subject to network availability, distance and line sync speed limitations.

CONFERENCE ROOMS THAT DRIVE BUSINESS

The Med/Surg Noise Reduction

EXECUTIVE SUMMARY. Telemedicine: It s Role in Medical Monitoring & Diagnostics

MMO

Kaba TouchGo opens doors with just a touch. The convenient locking system for care and nursing homes with dementia patients.

School Safety Audit Checklist

medical and commercial f ields.

Rauland Responder 4000

Rauland Responder 4000

Image 3. exclusive design to meet all your needs

WIRING DIAGRAM KITCHEN OUTLETS

Young Healthwatch Northamptonshire visit to Northampton General Hospital

PATIENT SAFETY IN A MENTAL HEALTH ENVIROMENT. 9 November 2016

Examination Centre Handbook 2014/2015

JABRA + LYNC FOR OFFICE 365 Enabling the power of conversation

Ascom MEDSTAR FRANKLIN SQUARE MEDICAL CENTER ASCOM COMMUNICATIONS STREAMLINE WORKFLOW THROUGH CLINICAL INTEGRATION. Introduction

10 Things To Know About

Comments by TeliaSonera on the VoIP consultation document

Monnal T75. Tailor-made breathing.

IPiN SYSTEM DESCRIPTION.

User-Service Manual Joerns Assist Handle Model F025

Tunstall telehealth solutions

GE Medical Systems Information Technologies. ApexPro FH Enterprise-Wide Telemetry

WELCOME TO THE INNOVATION UNIT Phase 2 Mobile Devices YOUR TRAINING GUIDE August 2015

iward SRP Innovating Nursing Care and Patient Experience

Comprehensive Staff and Patient Communications: Emphasizing Patient-Centered Care

ENTERPRISE with people in mind

Personal Health Monitoring Services SM VITAL SIGNS TRANSMITTER MODEL: VST 3 TM. Instruction Manual

econsult econsult Introduction & Training Manual

SONG FOR LINCOLNSHIRE 2018 ENTRY FORM

Element D Services Electrical

Wissner-Bosserhoff Aged Care Furniture

Happy patients, healthy patients. Solutions for interactive patient care

At your side in intensive care

VISOCALL IP. ALL IN ONE, ONE FOR ALL Communications in the healthcare sector HEALTH CARE

D Pure possibilities. Dräger perseus A500

GE Healthcare. Timeless exc ellence. CARESCAPE * V100 - Vital Signs Monitor

Prepublication Requirements

The Concept of C2 Communication and Information Support

Microprocessor Nurse Call System In-Service Training

Macfeat Early Childhood Lab School Emergency Plan Withers Building Room 41 Rock Hill, SC (803)

Sensor Assisted Care. Medical Automation Conference December 12, 2008

Element D Services Electrical

ORIENTATION HANDBOOK FOR AGENCY STAFF

Beechmount Care Home Service Adults 14 Ulundi Road Johnstone PA5 8TE Telephone:

The birth of a new era Excellent neonatal respiratory support at your fingertips DRÄGER BABYLOG VN500

Is your ward dementia-friendly? The EHE Environmental Assessment Tool

Application Notes for IgeaCare ApoloDS with Avaya IP Office Issue 1.0

Cisco Connected Real Estate for Healthcare: Changing How Hospital Real Estate is Developed, Used, and Managed

POLCIE, AMBULANCE, FIRE DEPARTMENT DIAL FIRE, DISASTER, EVACUATE 3 BELLS

Ontario School District 8C

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS FOR NC300 MICROPROCESSOR NURSE CALL SYSTEM

Anita Madden. Assignment White Paper ITEC 495 V1WW. Professor Wayne Smith

Extreme Collaboration. Tim Price-Walker Enterprise Business Consultant, Steljes

Using Electronic Surveillance Systems in. Why and How

@ncepod #tracheostomy

Centrella Smart+ Bed Because life-altering moments deserve elevated care

Centrella Smart+ Bed. Because life-altering moments deserve elevated care

Le Moyne College. BEICKERT AUDIO 219 Arnold Ave, Syracuse, NY Thomas J. Niland Jr. Athletic Complex SOUND STUDY QUOTATION.

SUDDEN DEATH POLICY Includes notification form for Sudden Unexplained Death in Infancy

COMMISSION DIRECTIVE 2011/18/EU

6-3 [D5A0] WIRING DIAGRAM. 5. Wiring Diagram. 5. Wiring Diagram A: POWER SUPPLY ROUTING

Diagram 1. Starting, charging and ignition (except fuel injection). Models up to Wiring diagrams

Kidz First Children s Hospital Information Booklet for Parent and Caregivers

Cabin Crew B787 SOP Cabin Layout Aircraft Configuration Special Seating Requirements Cabin Crew Stations Interphone Dimmable Window

operator-assisted conferencing when your event really matters

University College London Hospital

9 WAYS TO BOOST YOUR HCAHPS PATIENT SATISFACTION SCORES

Greencities offers news, tendencies, solutions and tools for the sustainable, efficient and intelligent management of cities.

InTouch Critical Care Bed. Basic needs. Simplified care. Exceptional outcomes.

28TH November - 1ST DECEmber PrICE LIST

SECURITY, EFFICIENCY AND ACCOUNTABILITY OF CONTROLLED DRUGS

MySign S, the original setting new standards in pulse oximetry

Welcome to Level 11 Gynaecology Ward

C4I System Solutions.

Transcription:

COMMUNICATION SYSTEM HCC-07.2 COMMUNICATION SYSTEM HCC-07.2 Nurse Call

COMMUNICATION SYSTEM HCC-07.2 Nurse Call The system offers a highly comfortable and clearly organised graphical user environment combined with simplicity of operation and control by function keys directly on the touch screen. The system is designed primarily for health care and for social care facilities hospital inpatient departments, medical institutions and sanatoria. This up-to-date communications equipment complies, in its basic principles, with all the European standards that are required of similar devices used in hospital-type environments. THE NEW MODEL SERIES WITH A TOUCH SCREEN INITIATES AN ENTIRELY NEW TREND IN HOSPITAL COMMUNICATIONS SYSTEMS This new system provides patients with high-quality, convenient voice communication with attending staff, connection of calls from the public telephone network to their bedside, and access to entertainment programs by the use of a bedside unit. Recording the history of all types of calls, precise localisation of the calling site and the operator s response time are a matter of course. The systems installed in individual departments can be connected as an integrated operational whole, which facilitates the creation of larger functional units with centralised management, e.g. during night hours. Main terminal MT-07.2 Clearly organised service panel with direct touch-screen control Clearly legible colour LCD display Unlimited number of calling sites Calling a subscriber by speed dial Option of discrete or speaker-on voice communication between medical staff and patients Speaker-on transmission of information to all rooms within one department (central announcements) Visual representation and localisation of staff presence on the terminal display Connecting of calls coming through a public network to an in-patient s bed Records of the history of all types of calls Recording the user s name Night operation THE MAJOR ADVANTAGES OF THE MAIN TERMINAL MT-07.2 55 MT-07D.2 NEW FEATURES Communication with the main terminal by means of LAN through the use of up-to-date VoIP technology 10.4 LCD panel (main terminal) with direct control on the touch screen Ergonomic positioning of the terminal Variable positions on the table or on the wall LAN interface for connection to the computer network USB port for data backup and SW upgrade Visual representation of the location of registered personnel (NURSE PRESENCE) Transferring operation to another department support for joining departments into larger units with centralised management of up to 10 departments (WARD COUPLING) Time filters for displaying calls (TIME ZONE NURSING) Extended records of the history of calls (times of call activation and of call processing) PHP server, on-line visual representation of the current status of main terminal, displaying the history of calls directly on the PC ERGONOMIC DESIGN TOUCH SCREEN WALL INSTALLATION SPEED DIAL USB - INTERFACE VoIP - LAN

CLEAR ARRANGEMENT AND EASE OF OPERATION Listening unit PB-07.2 Centralised listening to an entertainment program heard by all users through their communication units Entrance-door voice communication unit HV-07.2 Two-way speaker-on voice communication A full substitute for a so-called electronic doorkeeper at the entrance door; with the possibility of activation of an electric lock LED signal light SS-07L Optical indication whereby types of calls are differentiated In-room control box CB-07.2 Emergency call activation button BLUE CODE activation to summon a doctor or another helper Detecting the presence of a staff person in a room Receiving all types of calls from other rooms In-room control communication box CB-07H.2 BLUE CODE activation to summon a doctor or another helper Detecting the presence of a staff person in a room Receiving all type of calls from other rooms Two-way speaker-on voice communication Communication with any calling subscriber Listening to the central announcements transmitted from the main terminal In-room control box with a display CB-07D.2 BLUE CODE activation to summon a doctor or another helper Detecting the presence of a staff person in a room Receiving all type of calls from other rooms Two-way speaker-on voice communication Communication with any calling subscriber Displaying the type of call and the caller s localisation Listening to the central announcements transmitted from the main terminal

Calling cord with a microphone VS-07M.2 Speaker-on call and listening to entertainment programmes through a speaker by means of a socket Volume control for entertainment programmes Receiving phone calls from the public telephone network Easy identification of the call activation button during night hours (NIGHT BUTTON) Calling cord with a light control VS-07L.2 Speaker-on call through a speaker by means of a socket Receiving phone calls from the public telephone network Control of two lighting fixtures Easy identification of the call activation button during night hours (NIGHT BUTTON) NIGHT BUTTON Bedside communication unit with a light control SL-07L.2 Pneumatic switch PS-01.2 Emergency call activation by means of a pneumatic switch socket Acoustic switch AS-07.2 Emergency call acoustic activation Discrete voice communication and listening to entertainment programmes Speaker-on call and listening to an entertainment programmes through a speaker by means of a socket Volume control for entertainment programmes Receiving phone calls from the public telephone network Control of two lighting fixtures Easy identification of the call activation button during night hours (NIGHT BUTTON) Night mode

RELIABLE OPERATION Bedside socket with a speaker ZP-07R.2 Bedside socket ZP-07.2 Pneumatic switch socket ZS-07.2 Bedside socket with a holder for a receiver and/or button and with speaker ZP-07DR Bedside socket with a holder for a receiver and/or button ZP-07D Speaker unit RJ-07 Connection of bedside voice communication and signalisation components Discrete or speaker-on voice communication Speaker-on function for entertainment programmes and central announcements Usually installed on a lighting and installation panel above the patient s bed Connection of bedside voice communication and signalisation components (variant without a speaker) Usually installed on a lighting and installation panel above the patient s bed Connection of a pneumatic switch for the activation of emergency calls Connection and suspension of bedside voice-communication and signalisation components Discrete or speaker-on voice communication Speaker-on function for entertainment programmes and for central announcements Connection and suspension of bedside voice-communication and signalisation components (variant without a speaker) Holder for a receiver and/or button DS-07 Suspension of bedside voice-communication and signalisation components Listening to central announcements transmitted from the main terminal

Light and installation panel GREATER USER COMFORT Socket ZP-07.2 Socket ZP-07R.2 Socket with a holder ZP-07D Socket with a holder ZP-07DR Socket with a holder ZP-07DR Holder DS-07 installed on the wall Information display DI-07 Date and time display Identification of all types of calls and localisation of origin of call Emergency call button TK-07.2 Emergency call button and drawstring TH-07.2 Cordless portable button BT-07.2 Emergency call activation button Emergency call activation button and drawstring Cordless activation of emergency calls Worn suspended round the neck or attached to the arm in connection with either ZP-07.2 or ZP-07R.2

3 4 5 3 4 MODEL LOCATION OF COMPONENTS Nurse station 3 4 Examination room 7 9 9 13 12 7 3 4 Corridor 11 Doctor s room 7 6 Entrance 1 Bedside socket with a holder for a receiver and/or button ZP-07D Bedside communication unit with light control SL-07L.2 4 In-room control box with a display CB-07D.2 2 Bedside socket with a holder for a receiver and/ or button and with speaker ZP-07DR Calling cord with a microphone VS-07M.2 5 Listening unit PB-07.2 3 In-room control communication box CB-07H.2 6 Entrance-door voice communication unit HV-07.2 1 2 Patient room 8 8 Patient room 1 2 9 8 7 LED signal light SS-07L 8 Emergency call button and drawstring TH-07.2 9 Emergency call button TK-07.2 Ward bathroom 8 10 10 Pneumatic switch socket ZS-07.2 Pneumatic switch PS-01.2 11 Room control box CB-07.2 12 Main terminal MT-07.2 VARIANTS 1 2 3 4 8 10 13 Information display DI-07

BUSINESS DIVISION DATACOM Systems, s.r.o. Křížkovského 112, 757 01 Valašské Meziříčí Czech Republic tel.: +420 571 615 910, fax: +420 571 615 920 cell phone: +420 777 555 655, (Petr Nachtigal, Ph.D) e-mail: export@dcs-cz.eu, petr.nachtigal@gmail.com www.dcs-cz.eu w w w. c o d a c o. c z PR 0007 2010/03 CREATORS OF ELECTRONIC SYSTEMS ISO 9001:2008