IN HEALTHCARE, FOLLOWING BEST PRACTICES PROVIDES THE

Similar documents
INSTRUMENT CLEANING HAS BECOME A TOPIC OF INTEREST IN

Legal Implications Recommended Practices

CENTRAL SERVICE (CS) PERSONNEL AND THEIR HEALTHCARE

PROCESS IMPROVEMENT AND ENHANCED QUALITY CARE ARE THE

CENTRAL SERVICE (CS) PROFESSIONALS REQUIRE SIGNIFICANT

2016 Sterilization Standards Update

CENTRAL SERVICE (CS) TECHNICIANS PERFORM MANY IMPORTANT

HAVING THE CORRECT KNOWLEDGE TO ASK THE RIGHT

9/14/2017. Best Practices in Instrument Cleaning. Objectives. Healthcare-associated Infections

CENTRAL SERVICE (CS) IS A VITAL DEPARTMENT IN ANY HOSPITAL

CRCST Self-Study Lesson Plan Lesson No. CRCST 136 (Technical Continuing Education - TCE)

Reprocessing of Flexible Endoscopic Instruments

THE BEGINNING OF THE END OF THE FLASH DANCE, WHICH

Of Critical Importance: Infection Prevention Strategies for Environmental Management of the CSSD. Study Points

Endoscope Reprocessing

MANY ORGANIZATIONS ARE TAKING A CLOSER LOOK AT THE

3M Sterile U Network 3M Sterile U Web Meeting January 16, 2014

CLEANING Reusable Medical Devices. AAMI/FDA Medical Device Reprocessing Summit October 11-12, 2011 Silver Spring, MD

EVEN THOUGH THE ACCREDITATION PROCESS HAS BEEN IN PLACE

Charles Hughes. Instrument Reprocessing Update: What s New?

Surgical Instrumentation: Eliminating Chaos. The Complex Process of Surgical Instrument Maintenance and Improving the Healthcare Environment

Challenges in the US Approach to Disinfection and Sterilization

3M Sterile U Sterilization Assurance Continuing Education

Sterile Processing in Healthcare Facilities

Infection Control Policy and Procedure Manual. Post-Anesthesia Care Unit (Recovery Room) Page 1 of 6

BRIGHT EYES SESSION. Bridging the gap through collaboration:

May 9, Leslie Kux Associate Commissioner for Policy U.S. Food and Drug Administration 5630 Fishers Lane, Rm Rockville, MD 20852

HEALTHCARE FACILITIES ARE FACING INCREASING PRESSURE

Infection Prevention Checklist Section I: Policies and Practices I.1 Administrative Measures

Infection Control Checklist for Dental Settings Using Mobile Vans or Portable Dental Equipment. Guiding Principles of Infection Control:

Clinical staff undertaking Endoscopy and Nasendoscope interventions

Access to the laboratory is restricted when work is being conducted; and

STANDARD PRECAUTIONS POLICY Page 1 of 8 Reviewed: May 2017

Infection Control and Prevention On-site Review Tool Hospitals

NJ Dept of Health Central Service Standards SUBCHAPTER 8. CENTRAL SERVICE. 8:43G-8.1 Central service policies and procedures

Ambulatory Surgical Center (ASC) INFECTION CONTROL SURVEYOR WORKSHEET

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Pharmacy Sterile Compounding Areas

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

RESEARCH LABORATORIES CONDUCTING HIV/HBV RESEARCH AND PRODUCTION

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Guidelines for the Management of C. difficile Infections in. Healthcare Settings. Saskatchewan Infection Prevention and Control Program November 2015

INFECTION PREVENTION & CONTROL, INCLUDING PROCESSING ITEMS FOR REUSE, IN GENERAL PRACTICE

Guidance for the Selection and Use of Personal Protective Equipment (PPE) in Healthcare Settings

Policy - Infection Control, Safety and Personal Security

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Comply with infection control policies and procedures in health work

INFECTION CONTROL SURVEYOR WORKSHEET

Compounded Sterile Preparations Pharmacy Content Outline May 2018

ENDOSCOPY MICROBIOLOGY ALERTS PROCEDURE STANDARD OPERATING PROCEDURE

Infection Control in General Practice

Oregon Health & Science University Department of Surgery Standard Precautions Policy

Policy - Infection Control, Safety and Personal Security

RESPIRATORY PROTECTION PROGRAM

Duodenoscope Culture Methods Update

1.2 billion ambulatory care visits in US: physician offices, outpatient hospital and ED

NHS GREATER GLASGOW & CLYDE STANDARD OPERATING PROCEDURE (SOP)

AS/NZS 4187:2003 AS/NZS

Formaldehyde Program. For Compliance with Federal and State Regulated Carcinogen Regulations

INFECTION CONTROL POLICY DATE: 03/01/01 REVISED: 7/15/09 STATEMENT

10/11/2013. Immediate-Use Steam Sterilization in the OR. House Keeping. House Keeping. Questions. Martha Young, MS, BS,

Medical Equipment, Devices, & Supplies

8/9/2015. Fundamentals of Cleaning and Decontamination. Disclosure. Learning Objectives

26/04/2016. Welcome! House Keeping. From the GoToWebinar page:

Occupational safety in laboratories

Formaldehyde Exposure Control Plan

Australian/New Zealand Standard

Qmentum Program. Infection Prevention and Control Standards STANDARDS. For Surveys Starting After: January 01, Accredited by ISQua

Risk Assessment Tool for Infection Surveillance, Prevention and Control Programs In Ambulatory Healthcare Settings

Appendix AX: B Occupational Exposure to Bloodborne Pathogens Exposure Control Plan

Chapter 10. medical and Surgical Asepsis. safe, effective Care environment. Practices that Promote Medical Asepsis

Self-Assessment Summary Report 2017 Accreditation

DIRTY SCOPES: What You Need to Know About the New Reprocessing Guidelines and Infection Risk

: Hand. Hygiene Policy NAME. Author: Policy and procedure. Version: V 1.0. Date created: 11/15. Date for revision: 11/18

Hospital Acquired Infections and Prevention

Fall HOLLY ALEXANDER Academic Coordinator of Clinical Education MS157

Discussions and Activity at the Federal Level Regarding Management of Electronic Medical Equipment

Sterile Processing: Preparing for Accreditation Surveys. Monday, March 4, 2013, 8-9am & 9:30-10:30am

Infection Prevention and Control Assessment Tool for Outpatient Settings

Guidelines for Biosafety in Teaching Laboratories Using Microorganisms

ISOLATION TABLE OF CONTENTS STANDARD PRECAUTIONS... 2 CONTACT PRECAUTIONS... 4 DROPLET PRECAUTIONS... 6 ISOLATION PROCEDURES... 7

42 CFR Infection Control

Risk Assessment in the Sterile Processing Department: It s not what you know but what you don t

SPD Continuing Education Programs Last updated 4/23/2015

Ministry of Labour Occupational Health & Safety and Infection Prevention & Control

San Francisco General Hospital INFECTION CONTROL

Ebola guidance package

BLOODBORNE PATHOGENS EXPOSURE PREVENTION POLICY AND PROCEDURE BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Administrative Policies and Procedures. Policy No.: N/A Title: Medical Equipment Management Plan

Infection Prevention and Control in Ambulatory Care Settings: Minimum Expectations for Safe Care

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

CORPORATE SAFETY MANUAL

3M Sterilization Assurance Standards Practice. In Sterilization with the Core Four

Recommendation II. Recommendation I. Who s on Your Team? Recommendation III

Student Protocol for the Operating Room. Authored by: Vangie Dennis, RN, BSN, CNOR, CMLSO

PHYSICIAN PRACTICE ENHANCEMENT PROGRAM Assessment Standards. Infection Prevention and Control: Personal Protective Equipment

This course presents the applications of sterile processing theory in the clinical setting.

OR staffing supports the provision of safe perioperative patient care and promotes a safe perioperative environment

Allied institute of professional Studies N. Broadway. #340. Chicago, IL Page 1

Transcription:

by Susan Klacik, BS, CRCST, CIS, ACE, FCS, IAHCSMM Clinical Educator Keeping up with Duodenoscope and High-level Disinfection Best Practices LEARNING OBJECTIVES 1. Discuss the highlights of the newlyreleased Association of perioperative Registered Nurses Guideline for Manual Chemical High-Level Disinfection 2. Describe the recommendations to implement a surveillance sampling and culturing protocol for duodenoscopes IN HEALTHCARE, FOLLOWING BEST PRACTICES PROVIDES THE foundation for quality patient care; best practices are based upon research. This lesson plan presents highlights from two of the recently-released documents developed to advance the quality of patient care. OBJECTIVE 1: DISCUSS THE HIGHLIGHTS OF THE NEWLY- RELEASED ASSOCIATION OF PERIOPERATIVE REGISTERED NURSES GUIDELINE FOR MANUAL CHEMICAL HIGH-LEVEL DISINFECTION In January 2018, the Association of perioperative Registered Nurses (AORN) released its Guideline for Manual Chemical High-level Disinfection. This guideline is based on a comprehensive, systematic review of research- and nonresearch-based evidence. The guideline contains recommended best practices for safe and effective high-level disinfection (HLD) performed manually when automated methods are not possible. Research for this guideline consisted of 148 full-text sources that were independently evaluated and appraised according to the strength and quality of the evidence. Twelve recommendations within the guideline address how to safely and effectively perform manual HLD, particularly by thoroughly cleaning and following manufacturer s instructions for This series of self-study lessons on CS topics was developed by the International Association of Healthcare Central Service Materiel Management (IAHCSMM), and can be used toward CRCST re-certification or toward nursing credits. Pfeidler Enterprises and IAHCSMM both offer grading opportunities. Earn Continuing Education Credits Online: Nursing Credit: Pfiedler Enterprises will award nursing credit for this Self-Study Lesson Plan. Pfiedler Enterprises is a provider approved by the California Board of Registered Nursing, Provider Number CEP 14944, for 1 contact hour. Obtaining full credit for this offering depends upon attendance, regardless of circumstances, from beginning to end. Licensees must provide their license numbers for record keeping purposes. The certificate of course completion issued at the conclusion of this course must be retained in the participant s records for at least four (4) years as proof of attendance. In order to receive credit you must go to www.pfiedlerenterprises.com/iahcsmm/628 and complete the test, evaluation and registration forms. Once completed, you will be directed to print your certificate of completion. Scoring: IAHCSMM will award credit for this Self- Study Lesson Plan toward the renewal of a CRCST certification. To receive IAHCSMM credit, please visit www.iahcsmm.org for online grading (nominal fees will apply). Each online quiz with a passing score of 70% or higher is worth two points (2 contact hours) toward CRCST re-certification of 12 CEs. For more information: For questions or problems about Nursing Credits available for this lesson plan, please contact tonia@pfiedlerenterprises.com. For questions about IAHCSMM Credit available for this lesson plan, please contact us at 312.440.0078 or mailbox@iahcsmm.org. www.iahcsmm.org JULY / AUGUST 2018 Communiqué 53

use (IFU). The preferred method of HLD is through an automatic process such as an automatic endoscope reprocessor (AER). Automated methods, such as AERs, improve cleaning effectiveness, increase efficiency and minimize personnel exposure to hazardous chemicals. Reusable semi-critical items that have been validated by the manufacturer for sterilization should be sterilized, if possible, because HLD poses a greater risk of disease transmission than items processed by sterilization. The purpose of this guideline is to provide direction for: Performing safe and effective manual chemical HLD of reusable semi-critical items; and Preventing patient and healthcare worker injury associated with handling and use of liquid chemical high-level disinfectants. The selection of HLD is very important, so it is necessary to review all available options. An interdisciplinary team should perform a risk assessment for HLD or sterilization to review semi-critical devices that secondarily enter sterile tissue or the vascular system. HLD should be performed on the clean side of the department, in a low-traffic area that is controlled and maintained to prevent environmental contamination, cross contamination and employee exposure, while also improving efficiency and enhancing process control and monitoring. Warning signs should be posted at the entrance to alert staff about the potential for exposure to hazardous chemicals. Physical separation of decontamination activities from HLD is preferred because it reduces the risk of contamination. If having two separate rooms is not possible, the area performing HLD should be separated from the decontamination area by a minimum of three feet and by a separating wall HLD should be performed on the clean side of the department, in a low traffic area that is controlled and maintained to prevent environmental contamination, cross contamination and employee exposure, while also improving efficiency and enhancing process control and monitoring. Warning signs should be posted at the entrance to alert staff about the potential for exposure to hazardous chemicals. or a barrier that extends at least four feet above the sink rim. A one-way directional flow should be used to prevent recontamination of the item, while improving efficiency. Point-of-use cleaning and proper transport must occur as medical devices are sent to the decontamination area for cleaning. All medical devices must be thoroughly cleaned because high-level disinfectants are inactivated or become less effective in the presence of organic material. In addition, some high-level disinfectants act as fixatives, meaning they may fix organic soil and blood to the surface of the item being disinfected. As with all processes, following the manufacturer s IFU for HLD helps ensure the effectiveness of the disinfection process. The medical device IFU must also be carefully followed; the manufacturer has validation performed to ensure the device can be effectively disinfected, and provides validated instructions for HLD. Personal protective equipment (PPE) used for performing disinfection differs slightly from the PPE worn in the decontamination area. Masks and eyewear are required. Gloves should be chemical resistant and their selection should be based upon the recommendation of the HLD manufacturer. For the correct type of impervious gown/apron, the manufacturer s safety data sheet (SDS) should be consulted. If a respirator is needed, that will also be listed in the SDS. Testing must be done to verify that the HLD is effective for use [e.g., use of a test strip or other testing device that is specific to the HLD and the active ingredient in the disinfectant, and cleared by the US Food and Drug Administration (FDA)]. A calibrated thermometer to verify the temperature and a timer to verify the exposure time should also be used. Multi-part instrumentation should be disassembled, and the items should be completely immersed in the HLD solution. Moving parts should be actuated while immersed to ensure all surfaces are exposed to the high-level disinfectant. Lumened items should be flushed and completely filled with the high-level disinfectant. After disinfection, the device should be safely and thoroughly rinsed with sterile water. Rinsing is an extremely important step to remove the high-level disinfectant. Thorough rinsing and flushing helps prevent patient injury associated with any disinfectant remaining on the device. Using sterile water reduces the potential for introducing microorganisms onto the disinfected device. Rinse sinks should be located as close as possible to the high-level disinfectant soaking container. After rinsing, if the device will be stored for future use, it should be dried using a clean, lint-free cloth, and lumens should be flushed with instrument air. Once the disinfection process is 54 Communiqué JULY / AUGUST 2018 www.iahcsmm.org

NURSING LESSON PLAN complete, the item should be protected from contamination and clearly identified as processed and ready for use; this will help prevent confusion and the accidental use of a contaminated device. Methods to protect the disinfected item from contamination are discussed. Guidance is also provided for transferring a medical device that has undergone HLD onto a sterile field. A quality medical device processing program incorporates education and training. This new guideline states: The healthcare organization should provide initial and ongoing education and competency verification activities. It is the responsibility of the healthcare organization to provide initial and ongoing education and to verify the competency of its personnel; however, the primary responsibility for maintaining ongoing competency remains with the individual. 1 Providing patients with high-quality medical devices is the goal of this new AORN guideline. The recommendations, which are intended to be achievable, represent what is believed to be the best possible level of practice. OBJECTIVE 2: DESCRIBE THE RECOMMENDATIONS TO IMPLEMENT A SURVEILLANCE SAMPLING AND CULTURING PROTOCOL FOR DUODENOSCOPES. The FDA, Centers for Disease Control and Prevention (CDC) and the American Society for Microbiology (ASM), along with other endoscope culturing experts, have released a protocol for standardized duodenoscope surveillance sampling and culturing protocols titled Culturing Reducing the Risks of Infection. 2 This document provides protocols for surveillance sampling and culturing of reprocessed duodenoscopes. The International Association of Healthcare Central Service Materiel Management (IAHCSMM) also participated in the development of this document. This multi-agency document provides recommendations for healthcare facilities that choose to implement duodenoscope microbiological surveillance sampling and culturing. It was developed to detect organisms of concern, some of which have been associated with infectious outbreaks. These protocols are not intended to be used during a suspected outbreak linked to inadequately reprocessed endoscopes, and the results from following this protocol cannot be used to certify that an endoscope is sterile. Instead, it is intended as a quality control measure to demonstrate the effectiveness of reprocessing. Culturing information may be collected to monitor the facility specific procedures for reprocessing duodenoscopes and could be used to identify systematic errors in reprocessing or damaged endoscopes and equipment. The document is divided into three sections. The first section provides an overview and introduction to the sampling and culturing protocols. The second section identifies the materials and methods for duodenoscope sampling and recommends that it be conducted by appropriate personnel who are familiar with handling duodenoscopes (e.g., Central Service/Sterile Processing (CS/ SP) technicians or endoscopy staff). The third section provides four different methods to culture duodenoscopes, which are performed by appropriate microbiology laboratory staff; it also includes suggested initial limits for microbiological cutoffs based on expert opinion. Additionally, two appendices are included in the document: Appendix 1 includes suggested volumes for endoscope channels of various sizes. Appendix 2 incorporates photographs of duodenoscope sampling to illustrate duodenoscope design features and sampling equipment. Tables are also provided for examples of establishing microbial limits for endoscope culturing by healthcare facilities and are presented as limits low- to moderate-concern organisms and high-concern organisms. Guidance is provided on how to interpret the culture results for high-concern organisms and low- to moderate-concern concern organisms. Suggested responses for a healthcare facility to follow are based on the culture results, with results classified into four categories: action, alert, modified action and no action. Note: Except in areas where endoscope surveillance sampling and culturing is specifically required or regulated by state or local authorities, use of this protocol is not a mandatory component of a duodenoscope reprocessing program. Healthcare facilities that adopt endoscope surveillance sampling and culturing as a required policy should develop and follow their own written procedures, including any necessary remediation activities outlined in their policy. Samples from endoscopes are not considered clinical specimens from patients; they are being sampled for microbial culturing as a quality indicator. The decision to implement a duodenoscope surveillance sampling and culturing program should be made by a multidisciplinary task group that includes leadership from Endoscopy, CS/ SP, Infection Prevention and Control, Risk Management, Clinical Microbiology or Laboratory Medicine, Gastroenterology/ Gastrointestinal Surgery, and management within a healthcare facility. It is not recommended to transport the duodenoscopes to an offsite laboratory; such transport can allow for proliferation of microbes on the endoscope and increase the potential for environmental contamination of the endoscope. www.iahcsmm.org JULY / AUGUST 2018 Communiqué 55

Keeping current on best practices is very important, especially in rapidly-changing areas like endoscope processing and HLD. Carefully following the most current information may require some effort, but it is critically important for patient safety. CONCLUSION Keeping current on best practices is very important, especially in rapidly-changing areas like endoscope processing and HLD. Carefully following the most current information may require some effort, but it is critically important for patient safety. The duodenoscope multidisciplinary task group will need to determine the following matters as they relate to endoscope surveillance sampling and culturing in their institution: Frequency of sampling and culturing (including the choice of periodic sampling and culturing based on a period of time or number of procedures, or the option to sample and culture after every use of the device); Clinical use of duodenoscopes while awaiting culture results; Endoscopes to be sampled; Additional endoscope channels to be sampled; Endoscope handling after processing; How samples should be sent and received to the laboratory; Culture reporting format, identification of staff receiving culture results; Training and competency assessment for sampling and culturing staff; Duration of time to maintain endoscope culturing records; Threshold limits for low- to moderateconcern organisms; Frequency of review of this protocol; and Procedures to respond to endoscope culturing results, including when results exceed the predetermined microbial limits. Obtaining samples is complex and will require two trained individuals one to perform the sampling, maintain aseptic handling and perform brushing steps; the other to assist with opening packages and handling the unsampled portions of the endoscope. At least two samples should be collected and combined; an instrument channel sample (biopsy port to distal end) should be taken using a flush, brush, flush method, and an elevator recess sample should be taken by flushing and brushing of the elevator recess. For duodenoscopes with an open (unsealed) elevator wire channel, a third sample should be collected from the elevator wire channel by flushing that channel and combining the sample with the other two samples. Personnel should wear the appropriate PPE when handling the endoscopes for sampling. As a facility develops its plan for endoscope surveillance sampling and culturing, it is recommended to include responses to the culturing results when results exceed the predetermined microbial limits. It is also recommended that healthcare facilities have a plan to include a risk/ safety management response when high-concern organisms are cultured from reprocessed endoscopes. Examples of responses may include quarantine of endoscopes, retraining reprocessing staff on endoscope reprocessing protocols, conducting a risk/safety management response, and patient notification. Endoscope surveillance sampling and culturing records should be maintained by the healthcare facility s Infection Prevention and Control staff or other designated personnel, in accordance with the healthcare facilities record storage and retention policy. RESOURCES 1. Association of perioperative Registered Nurses. Guideline for Manual Chemical Highlevel Disinfection. In: Guidelines for Perioperative Practice. 2018. pp. 883-906. For additional information or to purchase the guideline, visit www.aorn.org. 2. Centers for Disease Control and Prevention. Culturing: Reducing the Risks of Infection. 3. US Food and Drug Administration. Culturing Reducing the Risks of Infection. Accessed May 8, 2018. 56 Communiqué JULY / AUGUST 2018 www.iahcsmm.org