S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * *

Size: px
Start display at page:

Download "S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * *"

Transcription

1 S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * * In the matter of the application of Michigan Electric Transmission Company, LLC ) for a certificate of public convenience and ) Case No. U necessity for the construction of a transmission ) line in Almena Township, Van Buren County, and ) Oshtemo Township, Kalamazoo County, Michigan ) ) QUALIFICATIONS AND DIRECT TESTIMONY OF LYNN M BECK MICHIGAN PUBLIC SERVICE COMMISSION November 30, 2012

2 QUALIFICATIONS OF LYNN M BECK CASE NUMBER U PART I Q. Please state your full name and business address for the record. A. My name is Lynn M. Beck, and my business address is the Michigan Public Service Commission s (Commission) temporary work site at 4300 West Saginaw Highway, Lansing, Michigan Q. By whom are you employed and what is your position? A. I am employed by the Commission as an Analyst for the Generation and Certificate of Need Section in the Electric Reliability Division. Q. Would you please outline your educational background? A. I obtained a Bachelor of Applied Science degree with a major in Environmental Technology from Sienna Heights University in Since joining the Commission, I have attended training programs sponsored by the National Association of Regulatory Utility Commissioners and Michigan State University including the Annual Regulatory Studies Program (August 2012) and the Advanced Regulatory Program: Ratemaking, Accounting, and Economics (October 2012). Q. Would you please outline your professional experience? A. From April 2005 to September 2007, I worked as a student assistant with the Michigan Department of Environmental Quality, Environmental Science and Services Division. My responsibilities included working with Section 313 (Title III) of the Superfund Amendments and Reauthorization Act, processing Toxic Chemical Release Inventory (TRI) reports, and processing 40 CFR 370 hazardous chemical inventory (Tier II) reports. I also assisted in reviewing and processing Annual Wastewater Reports for the Annual Wastewater Reporting Program. 1

3 QUALIFICATIONS OF LYNN M BECK CASE NUMBER U PART I In January 2011, I began working full time for the Department of Energy, Labor and Economic Growth, Bureau of Energy Systems as a Grant Administrator for the Energy Efficiency and Conservation Block Grant Program (EECBG), funded by the American Recovery and Reinvestment Act of 2009 (ARRA). During my employment at the Bureau of Energy Systems, now called the Michigan Energy Office, I was responsible for the oversight of the EECBG grant recipients, which included local units of government in Michigan, to ensure that their grant and all grant requirements were carried out successfully. I was also responsible for the development of the management timeline for the closeout of the federal ARRA grant between the US Department of Energy and the Michigan Energy Office In March 2012, I began working for the Generation and Certificate of Need Section within the Electric Reliability Division of the Michigan Public Service Commission. This Section handles utility applications for Certificate of Necessity cases under 2008 Public Act 286, Expedited Siting Certificates for transmission lines under 2008 Public Act 295, and Certificates of Public Convenience and Necessity for transmission lines under 1995 Public Act 30. In addition to these responsibilities, we also participate in the Midwest Independent System Operator (MISO) Transmission Expansion Plan (MTEP). MTEP is an annual process involving stakeholder reviews of proposed transmission projects submitted by Transmission Owners (TO) and utilities to MISO. This Section also conducts special assignments as directed by the Commission. 23 2

4 QUALIFICATIONS OF LYNN M BECK CASE NUMBER U PART I 1 2 Q. Have you previously presented testimony? A. No. 3

5 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II Q. What is the purpose of your testimony? A. The purpose of my testimony is to present the Michigan Public Service Commission Staff s (Staff) position in the matter of Michigan Electric Transmission Company s (METC) request for a Certificate of Public Convenience and Necessity (CPCN) pursuant to 1995 Public Act 30 (Act 30), MCL et seq. Q. What specific guidance was available to Staff in its review of METC s application for a CPCN in connection with METC s proposed Weeds Lake substation and transmission line installation? A. Staff relied upon Act 30, specifically MCL et seq. Q. What specific elements of METC s application will be covered by your testimony? A. My testimony will cover the application filing requirements outlined in MCL , MCL (2)(j), and MCL (1). Q. Are you sponsoring any exhibits in this proceeding? A. Yes. I am sponsoring Exhibits S-1 through S-3, and S Exhibit No. Exhibit S-1 Exhibit S-2 Exhibit S-3 Exhibit S-10 Description METC s response to question 41 of Staff s First Discovery Request The Kalamazoo Gazette distribution map The Courier-Leader distribution information METC s response to questions 1 through 3 of Staff s Fourth Discovery Request 4

6 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II Q. Did METC host a public meeting in each municipality through which the proposed transmission line passes, as outlined in MCL (1) of Act 30? A. Yes. According to testimony submitted by METC witness Mr. Gary R. Kirsh, METC held public meetings in both Almena and Oshtemo Townships on June 26 and 27, 2012, respectively. 1 Q. Did METC invite the chief elected official in each affected municipality to discuss the plans to construct the transmission line and potential routes prior to these public meetings, as outlined in MCL (2) of Act 30? A. Yes. On June 5, 2012, METC made two separate written offers to meet with the Almena Township Supervisor, Mr. Doug Stiles, and the Oshtemo Township Supervisor, Ms. Libby Heiny-Cogswell Q. What was the result of the written invitation to Almena Township Supervisor, Mr. Doug Stiles? A. According to METC witness Mr. Gary R. Kirsh s testimony, Almena Township declined to host such a meeting. 5 Q. What was the result of the written invitation to Oshtemo Township Supervisor, Ms. Libby Heiny-Cogswell? A. Oshtemo Township invited METC witness Mr. Gary R. Kirsh to attend the Oshtemo Township Board meeting on June 12, According to Mr. Kirsh s testimony, he did attend the meeting and presented the proposed and alternate 1 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, p 3. 2 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, p 5. 3 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, Exhibit A-13(GK-1). 4 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, Exhibit A-15(GK-3). 5 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, p 5. 5

7 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II transmission line routes, the Act 30 process, and informed the township board of the open house event on June 27, Q. Did METC include, in their application for a CPCN, a summary of all comments received at each public meeting, as outlined in MCL (2)(j)? A. Yes. The summaries are included in Exhibit A-18 (GK-6), attached to METC witness Mr. Gary R. Kirsh s testimony. 7 Q. Did METC include a summary of their responses to the comments mentioned above? A. Yes. The summaries of their responses are included in Exhibit A-18 (GK-6), attached to METC witness Mr. Gary R. Kirsh s testimony. 8 Q. Has METC submitted a full transcript from the aforementioned public meetings? A. Yes. In response to Staff s First Discovery Request, METC provided transcripts from both public meetings held on June 26 and June 27, 2012 in Almena and Oshtemo Townships respectively. The transcripts from both public meetings are included as Exhibit S-1. Q. Are you aware of any public outreach activities done by METC prior to the filing of the application? A. Yes. In addition to the aforementioned public meetings, METC held an open house at the Prairie Ridge Elementary School in Kalamazoo, MI on June 23, Maps and other relevant information were available for public review, and 6 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, p 5. 7 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, Exhibit A-18(GK-6). 8 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, Exhibit A-18(GK-6). 6

8 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II METC representatives were available to discuss issues and answer questions. Also, on November 7, 2011, METC held an informational meeting at the Kalamazoo Holiday Inn, in which all affected landowners along the potential routes were invited to attend Q. METC witness Mr. Gary R. Kirsh included the phrases open house and 6 7 informational meeting in his testimony. 11 two? Is there a difference between the A. No. According to METC s response to Staff s fourth discovery request, the terms open house and informational meeting have the same meaning. 12 Q. Act 30, MCL (1) specifies the requirements for posting a public notice for the opportunity to comment on the application for the CPCN. What media outlet(s) did METC use to publish the notice? A. METC published the Notice of Hearing and Notice of Opportunity to Comment in both The Kalamazoo Gazette and The Courier-Leader, both local newspapers in the greater Kalamazoo area. 13 Q. What dates were the notices published? A. Notice was published in The Kalamazoo Gazette on August 28, 2012, and in The Courier-Leader on August 24, Q. What is the distribution area of The Kalamazoo Gazette? 9 Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, pp See Staff Exhibit S Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, pp See Staff Exhibit S

9 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II A. The Kalamazoo Gazette covers all of Kalamazoo and St. Joseph counties, and parts of Van Buren, Allegan, and Barry counties in southwest Michigan. A map of the distribution area is included as Exhibit S-2. Q. What is the distribution area of The Courier-Leader? A. The Courier-Leader is distributed in parts of Van Buren and Kalamazoo counties, in southwest Michigan. Information regarding the distribution of the Courier- Leader is included as Exhibit S-3. Q. Does the distribution area of these publications include the entire geographic area of the proposed transmission project? A. Yes. Q. According to the guidance under Act 30, MCL (1), Notice shall be sent to each affected municipality and each affected landowner on whose property a portion of the proposed major transmission line will be constructed. Has METC provided a list of property owners which they sent the notice to? A. Yes. The list is included as MPSC Docket No for Case No. U-17041, dated 09/06/ Q. Has the Commission Staff validated the above list for accuracy? How was that validation performed? A. Yes. Staff submitted discovery to METC requesting a map identifying the proposed and alternate routes, all parcel lines, and any permanent structures located within either route s right-of-way. METC provided a map which included

10 DIRECT TESTIMONY OF LYNN M BECK CASE NUMBER U PART II 1 the proposed and alternate route, all affected parcels, and their respective 2 owners. 16 Staff then validated the list with the map which METC provided Q. What date did they send the notice? A. METC sent the notice to affected municipalities and landowners on August 22, However, one landowner was sent notice on August 23, Q. What is Staff s conclusion? A. Staff concludes that METC has satisfied the requirements as outlined by Act 30, MCL , MCL (2)(j), and MCL (1) in their CPCN application filing. Q. Does this complete your testimony? A. Yes, it does. 16 See Staff Exhibit S

11 S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * * In the matter of the application of ) Michigan Electric Transmission Company, LLC ) for a certificate of public convenience and ) Case No. U necessity for the construction of a transmission ) line in Almena Township, Van Buren County, and ) Oshtemo Township, Kalamazoo County, Michigan. ) ) EXHIBITS OF LYNN M. BECK MICHIGAN PUBLIC SERVICE COMMISSION November 30, 2012

12 Exhibit No.: S-1 Page: 1 of 63

13 Exhibit No.: S-1 Page: 2 of 63

14 Exhibit No.: S-1 Page: 3 of 63

15 Exhibit No.: S-1 Page: 4 of 63

16 Exhibit No.: S-1 Page: 5 of 63

17 Exhibit No.: S-1 Page: 6 of 63

18 Exhibit No.: S-1 Page: 7 of 63

19 Exhibit No.: S-1 Page: 8 of 63

20 Exhibit No.: S-1 Page: 9 of 63

21 Exhibit No.: S-1 Page: 10 of 63

22 Exhibit No.: S-1 Page: 11 of 63

23 Exhibit No.: S-1 Page: 12 of 63

24 Exhibit No.: S-1 Page: 13 of 63

25 Exhibit No.: S-1 Page: 14 of 63

26 Exhibit No.: S-1 Page: 15 of 63

27 Exhibit No.: S-1 Page: 16 of 63

28 Exhibit No.: S-1 Page: 17 of 63

29 Exhibit No.: S-1 Page: 18 of 63

30 Exhibit No.: S-1 Page: 19 of 63

31 Exhibit No.: S-1 Page: 20 of 63

32 Exhibit No.: S-1 Page: 21 of 63

33 Exhibit No.: S-1 Page: 22 of 63

34 Exhibit No.: S-1 Page: 23 of 63

35 Exhibit No.: S-1 Page: 24 of 63

36 Exhibit No.: S-1 Page: 25 of 63

37 Exhibit No.: S-1 Page: 26 of 63

38 Exhibit No.: S-1 Page: 27 of 63

39 Exhibit No.: S-1 Page: 28 of 63

40 Exhibit No.: S-1 Page: 29 of 63

41 Exhibit No.: S-1 Page: 30 of 63

42 Exhibit No.: S-1 Page: 31 of 63

43 Exhibit No.: S-1 Page: 32 of 63

44 Exhibit No.: S-1 Page: 33 of 63

45 Exhibit No.: S-1 Page: 34 of 63

46 Exhibit No.: S-1 Page: 35 of 63

47 Exhibit No.: S-1 Page: 36 of 63

48 Exhibit No.: S-1 Page: 37 of 63

49 Exhibit No.: S-1 Page: 38 of 63

50 Exhibit No.: S-1 Page: 39 of 63

51 Exhibit No.: S-1 Page: 40 of 63

52 Exhibit No.: S-1 Page: 41 of 63

53 Exhibit No.: S-1 Page: 42 of 63

54 Exhibit No.: S-1 Page: 43 of 63

55 Exhibit No.: S-1 Page: 44 of 63

56 Exhibit No.: S-1 Page: 45 of 63

57 Exhibit No.: S-1 Page: 46 of 63

58 Exhibit No.: S-1 Page: 47 of 63

59 Exhibit No.: S-1 Page: 48 of 63

60 Exhibit No.: S-1 Page: 49 of 63

61 Exhibit No.: S-1 Page: 50 of 63

62 Exhibit No.: S-1 Page: 51 of 63

63 Exhibit No.: S-1 Page: 52 of 63

64 Exhibit No.: S-1 Page: 53 of 63

65 Exhibit No.: S-1 Page: 54 of 63

66 Exhibit No.: S-1 Page: 55 of 63

67 Exhibit No.: S-1 Page: 56 of 63

68 Exhibit No.: S-1 Page: 57 of 63

69 Exhibit No.: S-1 Page: 58 of 63

70 Exhibit No.: S-1 Page: 59 of 63

71 Exhibit No.: S-1 Page: 60 of 63

72 Exhibit No.: S-1 Page: 61 of 63

73 Exhibit No.: S-1 Page: 62 of 63

74 Exhibit No.: S-1 Page: 63 of 63

75 Exhibit No.: S-2 Page: 1 of 1

76 Exhibit No.: S-3 Page: 1 of 1 Vineyard Press, Inc E. Red Arrow Hwy, Paw Paw MI COURIER LEADER CIRCULATION ALL 490 LABELS ONLY 1091 NON 490 LABELS 160 LOCAL DROPS 725 COMPLIMENTARY 100 TOTAL CIRCULATION 2076 *(includes store drops as shown below) ********************************************************** BREAKDOWN BY ZIP CODES FOR 490 LABELS: Decatur Gobles plus*(50 store drops) Kalamazoo Lawrence plus*(140 store drops) Lawton plus*(120 store drops) Mattawan plus*(100 store drops) Paw Paw plus*(315 store drops) MISC 490 s 45 Total 490 Labels 1091 October 4, 2012

77 Exhibit No.: S-10 Page: 1 of 2

78 Exhibit No.: S-10 Page: 2 of 2

79 S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * * In the matter of the application of ) Michigan Electric Transmission Company, LLC ) for a certificate of public convenience and ) Case No. U necessity for the construction of a transmission ) line in Almena Township, Van Buren County, and ) Oshtemo Township, Kalamazoo County Michigan. ) ) QUALIFICATIONS AND DIRECT TESTIMONY OF NAOMI J. SIMPSON MICHIGAN PUBLIC SERVICE COMMISSION November 30, 2012

80 QUALIFICATIONS OF NAOMI J. SIMPSON CASE NUMBER U PART I Q. Please state your full name and business address for the record. A. My name is Naomi J. Simpson, and my business address is the Michigan Public Service Commission s (Commission) temporary work site at 4300 West Saginaw Highway, Lansing, Michigan Q. By whom are you employed and in what capacity? A. I am employed in the Electric Reliability Division (ERD) of the Michigan Public Service Commission. I am an engineer in the Generation and Certificate of Need Section which is responsible for evaluating generation and transmission expansion plans. Q. Would you please outline your educational background? A. I earned a Bachelor of Science degree in Engineering with a major in Industrial Design from Michigan State University in 1997 and a Master of Science in Education with a major in Secondary Education from the University of Phoenix in Since joining the Commission, I have also attended several training programs sponsored by the National Association of Regulatory Utility Commissioners and Michigan State University, including the Annual Regulatory Studies Program (August 2011, 2012), the Advanced Regulatory Studies Program (October 2011, 2012), and Introduction to Public Utility Regulation and Ratemaking (May 2012). I have also attended the Distribution Efficiency Planning and Voltage Optimization conference sponsored by Electric Utility Consultants, Inc. Q. Would you please outline your professional experience? 1

81 QUALIFICATIONS OF NAOMI J. SIMPSON CASE NUMBER U PART I In September 1994, I began working at General Motors Corporation as a student engineer where I evaluated systems and components related to meeting vehicle EPA emissions standards and fuel efficiency In February 1998, I began working for Delphi Automotive Corporation as a Design and Release Engineer for vehicle platform exhaust systems. My duties included design team management, production approval, and lean manufacturing implementation. Lean manufacturing of production systems included creating an optimization plan for manufacturing while taking into account material conservation and energy efficiency throughout the manufacturing process. In August 2000, I became the Change Management Coordinator for the Delphi Lansing Cockpit Plant with responsibility for plant wide change management, plant-wide SAP system coordination and training, lean manufacturing, and cost reduction. In November 2004, I was assigned the duties of Quality Manager with responsibility for plant wide first-time-quality goals, root cause analysis, supplier quality standards, and statistical defect analysis. In addition, I organized cost saving and lean manufacturing workshops which included energy conservation, material conservation, and energy efficiency throughout the manufacturing process In March 2011, I began working as a Public Utilities Engineer in the Smart Grid Section of the ERD for the Michigan Public Service Commission Staff (Staff). I was a member of the Smart Grid Collaborative as the co-chair of the Customer 2

82 QUALIFICATIONS OF NAOMI J. SIMPSON CASE NUMBER U PART I Programs and Communications workgroup. I was also a contributing member of the Regulatory Policy and Grid Applications workgroups. I have provided extensive assistance with the analysis of Consumers Energy Company s Advanced Metering Infrastructure/ Smart Grid proposal and request for recovery in Case No. U I have assisted in writing several portions of the U Staff report to the Commission. I have provided assistance to Staff witnesses in Case No. U-17026, Indiana Michigan Power Company s application for a certificate of necessity. Q. Have you previously presented testimony before the Commission? A. Yes. I prepared and filed testimony for Case No. U-16801, Indiana Michigan Power Company electric rate case. 3

83 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II Q. What is the purpose of your testimony? A. The purpose of my testimony is to present Staff s position in the matter of Michigan Electric Transmission Company s (METC) application for a Certificate of Public Convenience and Necessity (CPCN) pursuant to 1995 PA 30 (Act 30), MCL et seq. Q. What specific elements of METC s application will be covered in your testimony? A. My testimony will cover the application filing requirements outlined in MCL and MCL Q. What approach did Staff use in conducting its review of METC s application for a CPNC in this case? A. Staff conducted a review of the METC transmission project through the Midwest Independent System Operator (MISO) Transmission Expansion Plan (MTEP) process; conducted a detailed review of the application filing and related documents pursuant to the specific requirements in Act 30; issued discovery and follow-up discovery requests for supplemental information related to the application from all parties as needed. Q. Are you sponsoring any exhibits in this proceeding? A. Yes. I am sponsoring Staff Exhibits S-4 through S-9 and S Exhibit No. Description Exhibit S-4 METC response to Staff s third discovery request, question 1 Exhibit S-5 METC response to Staff s first discovery request, question 19 Exhibit S-6 METC response to Staff s first discovery request, question 4 4

84 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II Exhibit S-7 METC response to Staff s first discovery request, question 21 Exhibit S-8 METC response to Staff s third discovery request, question 6 Exhibit S-9 METC response to Staff s first discovery request, question 39 Exhibit S-11 METC response to Staff s fourth discovery request, question 5 Q. Please generally describe the requirements outlined in Act 30, MCL A. MCL requires an applicant planning to construct a major transmission line in this state in the five (5) years after planning commences, the applicant shall submit a construction plan to the Commission. Further, MCL identifies specific required information that shall be contained within the construction plan upon submittal. Q. Based upon Act 30 MCL , is METC required to include a construction plan with their application for the proposed transmission project? A. No. METC is not required to include a construction plan with their application. As indicated by Staff witness Steven Kulesia, METC is not proposing a major transmission line. MCL establishes guidelines for a certificate other than a major transmission line. MCL (3) specifically states that Section 4 does not apply to a transmission line for which a certificate is sought under this section. 1 Q. During the review of METC s application for the proposed transmission line project, did Staff do any computer modeling? 1 5

85 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II A. No. Staff does not have sufficient personnel and resources to perform transmission system computer modeling at the present time, however, MISO performs computer modeling studies and analysis for transmission projects approved through the MTEP process. Q. Does Act 30 describe specific information that is to be required in an application for a certificate? A. Yes. MCL of Act 30 states the following: Sec. 7. (2) An application for a certificate shall contain all of the following: (a) The planned date for beginning construction. (b) A detailed description of the proposed major transmission line, its route, and its expected configuration and use. (c) A description and evaluation of 1 or more alternate major transmission line routes and a statement of why the proposed route was selected. (d) If a zoning ordinance prohibits or regulates the location or development of any portion of a proposed route, a description of the location and manner in which that zoning ordinance prohibits or regulates the location or construction of the proposed route. (e) The estimated overall cost of the proposed major transmission line. (f) Information supporting the need for the proposed major transmission line, including identification of known future wholesale users of the proposed major transmission line. 6

86 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II (g) Estimated quantifiable and nonquantifiable public benefits of the proposed major transmission line. (h) Estimated private benefits of the proposed major transmission line to the applicant or any legal entity that is affiliated with the applicant. (i) Information addressing potential effects of the proposed major transmission line on public health and safety. (j) A summary of all comments received at each public meeting and the applicant s response to those comments. (k) Information indicating that the proposed major transmission line will comply with all applicable state and federal environmental standards, laws, and rules. (l) Other information reasonably required by the commission pursuant to rule. Q. Can you explain the results of Staff s review of METC s compliance with each of these requirements outlined in MCL ? A. Yes. Staff will explain the results of its review of each of the MCL (2) requirements identified in Act 30 and their relationship to the specific elements of the application for certificate. Q. Did METC s application include a planned date for the beginning of construction? A. Yes. METC witness Jason Sutton states that construction will likely begin on or about April 1, 2014 pending the issuance of a certificate of public convenience and necessity from the Michigan Public Service Commission. 2 2 Prefiled Direct Testimony and Exhibits of Jason Sutton, p 7. 7

87 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II Q. Does Staff have a position with regards to METC s planned date for the beginning of construction as stated in its application? A. Yes. According to MCL (4) [t]he commission shall grant or deny the application for a certificate not later than 1 year after the application s filing 5 date. 3 Therefore, Staff maintains that the April 1, 2014 date is a reasonable date for the start of the proposed transmission project. Staff understands that there are project management activities such as planning, project design, and equipment procurement that precede the physical start of construction of the transmission project. Q. Has METC provided a detailed description of the proposed transmission line, its route, and its expected configuration and use? A. Yes. METC witness Carlo Capra describes the proposed transmission project as consisting of a new 345/138 kv substation and four 138 kv circuits on two double circuit transmission steel monopole lines. The new substation, identified as Weeds Lake Substation would be located on 41 acres in Almena Township. The substation will be designed to connect to the existing Argenta to Robinson Park 345 kv line. Power from the 345 kv line will flow down to the 138 kv system through one 345/138 kv transformer providing the Kalamazoo area a new power source from the south The two new double circuit pole lines will connect to the Weeds Lake substation and extend eastward in parallel approximately six miles. One double circuit pole 3 8

88 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II line will connect to an existing 138 kv circuit between Bronco and 12 th Street substation creating two new 138 kv circuits. The other double circuit pole line will connect to an existing 138 kv circuit between Drake Road and Milham substations creating another two new 138 kv circuits. Further description can be found in METC witness Carlo Capra s testimony 4 and METC witness Jason Sutton s testimony. 5 Q. Did METC provide a detailed description of the purpose for the proposed transmission project and why it is needed? A. Yes. METC has provided testimony and exhibits supporting the project based upon system reliability. As stated in Mr. Capra s testimony, this project addresses NERC criteria TPL-002a 6 for the shutdown of one transformer plus the 12 contingent loss of a second. 7 [T]he proposed transmission line was identified as the best solution to this planning criteria violation and submitted to the MISO for further evaluation in its 2009 MISO Transmission Expansion Plan (MTEP). 8 Q. Did METC consider other alternative transmission projects to address the above mentioned planning criteria violation? A. Yes. METC identified several other alternative solutions which were considered. Alternatives included different combinations of new substations, new transmission lines, and additional transformers. METC and MISO used transmission system data to evaluation alternatives. The proposed project was 4 Prefiled Direct Testimony and Exhibits of Carlo Capra, pp Prefiled Direct Testimony and Exhibits of Jason Sutton, pp Prefiled Direct Testimony and Exhibits of Carlo Capra, p 7. 8 Prefiled Direct Testimony and Exhibits of Carlo Capra, p 8. 9

89 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II found to be the most satisfactory solution to the planning criteria violation by providing for a balanced and reliable transmission system throughout the Kalamazoo area. The project was subsequently approved in MISO s MTEP 2009 process. Q. Has METC provided a detailed description of the preferred route? A. Yes. METC witness Stephen Thornhill describes the preferred route in detail. The routes are identified in Mr. Thornhill s testimony as R2 and R38. 9 Additionally, METC Exhibit A-11 (ST-2), Figure 4-2 contains an aerial map of 9 the preferred route. 10 METC also provided a more comprehensive aerial map in response to a Staff discovery request. This aerial map is included as Exhibit S This map illustrates the discrete parcels located along the proposed route. Q. Has METC provided a detailed description of at least one alternative route, and a statement of why the preferred route was selected? A. Yes, METC provided a detailed description of an alternative route in METC 15 witness Stephen Thornhill s testimony. 12 The alternative route is further 16 illustrated in Exhibit A-11 (ST-2), Figure 4-3 as an aerial map. 13 METC also 17 provided a more comprehensive aerial map in response to a Staff discovery request. Staff has included this aerial map as Exhibit S the discrete parcels located along the proposed route. This map illustrates 9 Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, pp Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, Exhibit A-11(ST-2). 11 See Exhibit S Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, pp Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, Exhibit A-11(ST-2). 14 See Exhibit S-4. 10

90 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II During the evaluation of the preferred route and the alternative route, METC witness Mr. Thornhill states that the Preferred Route takes a more northerly path, slightly longer but providing additional distance from homes and equestrian facilities on the Thousand Oaks farm, crossing at the back of a large parcel rather than crossing the entrance way to a home and equestrian facility, and requiring less woodland clearing than the Alternate Route Therefore, it is Staff s position that METC provided the rationale for selecting their preferred route, as well as a detailed description of one alternate route in their application. Q. Does Staff have any comments regarding the elimination of the southern route alternatives, originally identified in the routing study as route segments within the I-94 corridor, being dropped from consideration? A. METC has presented information addressing concerns with potential routes through the I-94 corridor. Several engineering challenges, construction and maintenance safety issues, and traffic flow concerns exist with a project in the I- 94 corridor. 16 METC s response to Staff s discovery request, included as Staff Exhibit S-4, 14 provides further insight to considerable obstacles along the I-94 corridor including existing water/sewer pipelines, adjacent residential and commercial development, communications facilities, road overpasses, and 15 Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, p Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, p

91 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II potential future Michigan Department of Transportation plans for I-94 expansion resulting in clearance conflicts with a transmission line. 17 Q. What is Staff s position regarding METC s decision to remove routes through the I-94 corridor from consideration for the proposed transmission project? A. Based upon the information provided, Staff agrees with METC s decision to remove routes along the I-94 corridor from further consideration. Q. Does Staff have any comments with regard to METC s route selection process? A. Yes. The route selection process considered many social, environmental, and engineering impacts of the proposed transmission project. METC witness Stephen Thornhill s testimony highlights a number of federal, state, and local agencies involved in providing information about resources, potential issues, and land use within the study area. Criteria weights were established through consultation with local, state and federal agencies, property owner comments, 16 METC staff, and Burns & McDonnell s professional judgment. 18 Given that there are potentially hundreds of routes that could suffice; the method of applying weighted criteria provides a systematic approach to the route screening process. Q. Is Staff aware of any zoning ordinance that prohibits or regulates the location or development of any portion of the proposed route? 17 See Exhibit S Prefiled Direct Testimony and Exhibits of Stephen G. Thornhill, Exhibit A-11(ST-2). 12

92 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II A. Yes, Staff is aware of Oshtemo Township Ordinance No This Township ordinance potentially impacts zoning relative to utility infrastructure location and development. Staff further notes that METC has addressed the impact of this ordinance through the testimony of METC witness Jason Sutton. As described in Mr. Sutton s testimony, Oshtemo Township amended its Utility Control ordinance, Number 114, with the adoption of Ordinance Number 525 on November 22, The Ordinance, as amended, contains specific requirements that would likely impact the location and development of the proposed transmission project. These requirements include: various plan submissions, Township Board approvals, Township Zoning Ordinance analysis, and undergrounding requirements In addition, Oshtemo Township witness Elizabeth Heiny-Cogswell s testimony identifies two ordinances that potentially impact the location and development of utility infrastructure by requiring development underground. The two ordinances are the Subdivision Site Condominium Ordinance No. 467 and the Cable System Regulatory Ordinance No Q. Has METC included an estimated overall cost of the proposed transmission project? A. Yes. METC has provided an overall cost estimate for the project totaling $45 million dollars. Staff notes that this is an increase over the original MTEP Prefiled Direct Testimony and Exhibits of Jason Sutton, pp Prefiled Direct Testimony and Exhibits of Elizabeth Heiny-Cogswell, pp

93 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II 1 estimate of $39,800,002. METC sites several reasons for the revised cost 2 estimate presented in their application. 21 The substation estimates decreased with the refined scope of work. However this was countered by an increased scope of work at the Argenta and Milham sites. In addition, overhead line costs have been further refined as to the overall number and cost of structures, wires, fiber optic communications wire, and related labor. METC was also able to incorporate new information from the routing study which further refined the cost estimates. Q. Has METC provided information supporting the need for the proposed transmission project, including identification of known future wholesale users of the proposed transmission line? A. Yes. METC has provided information supporting the project need based upon system reliability. The proposed transmission line allows METC to be compliant 13 with NERC s mandatory reliability standards. 22 METC s witness Mr. Capra has provided Exhibit A-2 (CC-2) illustrating the potential overload scenarios of the current system. Additionally, METC has provided an estimated amount of time 16 required to conduct the replacement of a transformer. 23 This also provides insight 17 about the time required to replace a transformer if one should fail METC witness Mr. Capra s testimony also identifies a concern for other connection losses: the 345 kv sources into the Argenta station, the 138 kv facilities that bring the power down to the Kalamazoo area or the connection 21 See Exhibit S Prefiled Direct Testimony and Exhibits of Carlo Capra, p See Exhibit S-7. 14

94 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II 1 between these two sets of facilities. 24 The Weeds Lake project would help to reduce the risk of a widespread outage across the Kalamazoo area by providing an alternate source of power on the 138 kv system that services the Kalamazoo area METC identified Consumers Energy Company as the most likely wholesale user of the proposed transmission line, however, METC noted that all transmission customers taking service under the MISO open access transmission tariff are potential users of the proposed line. 26 Q. Has METC included an estimate of quantifiable and nonquantifiable public benefits of the proposed transmission line affiliated with its application? A. Yes, METC has included estimated quantifiable and nonquantifiable public benefits. According to METC witness Carlo Capra, The proposed transmission line allows METC to fully meet NERC s mandatory reliability standards. 27 Additionally, the proposed transmission project largely benefits the customers in the greater Kalamazoo and Battle Creek area by reducing the risk of rolling brownouts or blackouts 2829 and increasing the transfer capacity in the area at least MW. 30 The line will also benefit all METC customers by reducing system 24 Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Carlo Capra, p See Exhibit S See Exhibit S-8. 15

95 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II loses during peak loading conditions therefore reducing the amount of power generation needed to meet demand. 31 Q. Has METC included an estimate of private benefits of the proposed major transmission line affiliated with its application? A. Yes. A discussion about private benefits of the proposed transmission project is 6 included in METC witness Carlo Capra s testimony. 32 The investment in the proposed transmission project would be included in FERC-jurisdictional transmission rates. The investment would earn a rate of return set by FERC formula rates. Q. Has METC included information addressing potential effects of the proposed transmission project on public health and safety? A. Yes. METC has provided information addressing public health and safety. METC s witness Jason Sutton has indicated that METC s design and construction specifications meet or exceed the Institute of Electrical and Electronics 15 Engineers/NESC requirements. 33 According to Mr. Sutton, all of METC s contractors are also required to meet all NESC and OSHA/MIOSHA standards. METC s field supervisors and engineers will monitor contractor compliance. Q. Did METC provide any other information that may relate to public health and safety beyond the physical design and construction of the transmission project? 31 Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Carlo Capra, p Prefiled Direct Testimony and Exhibits of Jason Sutton, p

96 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II 1 2 A. Yes. METC witnesses J. Michael Silva, Dr. Mark Israel and Dr. H. Dwight Mercer provided testimony related to electric and magnetic fields (EMF) Mr. Silva conducted measurements of magnetic fields in the area of the proposed transmission project and evaluated the EMF levels for the proposed lines. Mr. Silva concluded that [t]he EMF levels from the proposed transmission lines are below the levels recommended by credible international expert organizations for public exposures and the magnetic field levels from the line are within the range of EMF that people can experience every day in their normal living and working environments Dr. Israel conducted an evaluation of EMF research with a focus on laboratory studies on animals and cells relevant to cancer causation and development. Dr. Israel concluded that there is no reliable scientific basis to conclude that exposure to power frequency EMF from the proposed transmission line project will cause or contribute to the development of cancer in children or adults along the proposed project s route Dr. Mercer reviewed studies related to EMF and animal health. Dr. Mercer stated that in his opinion, there is no reliable scientific basis to conclude that the power frequency EMF from the proposed Weeds Lake 138 kv transmission line project 34 Prefiled Direct Testimony of J. Michael Silva, P.E., p Prefiled Direct Testimony of Mark A. Israel, M.D., p

97 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II will cause or contribute to adverse health effects in animals living along the route of the transmission lines. 36 Q. Has METC provided Staff with a summary of all comments received at each public meeting and the applicant s response to those comments? A. Yes. As Staff witness Lynn Beck noted in her direct testimony, METC provided a summary of all comments received during the public meetings held in Almena Township on June 26, 2012 and Oshtemo Township on June 27, METC also provided Staff with a complete transcript of both public meetings in METC s response to Staff Discovery ST-METC Q. What is Staff s position with regards to the quality of the public comments summary provided in METC s application? A. After comparing the summary 38 to the transcript, 39 Staff notes that METC s summaries were over simplified or abbreviated, such that METC s summary of the questions and comments lost their originally intended meanings. Q. Does Staff offer any position regarding METC s responses to the public comments received during the public meetings? A. Although Act 30 does not require METC to respond to public comments, Staff s position is that METC should make every attempt to address commenter concerns in the interest of open and transparent communication. As noted in the public meeting summary and transcript, METC did not attempt to provide a response to several comments. Staff notes that METC did address many of these topics 36 Prefiled Direct Testimony of H. Dwight Mercer, PHD, DVM, p See Exhibit S Prefiled Direct Testimony and Exhibits of Gary R. Kirsh, Exhibit A-18 (GK-6). 39 See Exhibit S-1. 18

98 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II within their application, however the affected landowners would have benefited from complete responses to the questions posed during the public meeting process. Q. Has METC included information indicating that the proposed transmission project will comply with all applicable state and federal environmental standards, laws, and rules? A. Yes. METC has included a discussion of applicable environmental standards, 8 9 laws and rules as part of METC witness Steven Koster s Testimony. 40 goes on to explain METC s plan for complying with all environmental Mr. Koster 10 requirements. 41 METC also indicated in response to Staff discovery ST-METC that METC plans to coordinate with the Michigan Department of Natural Resources to develop the project in a manner compatible with a No Effect determination. 42 Q. Does Staff request any specific documentation of environmental regulations or associated permits and statements for the proposed transmission project? A. In the interest of transparency, Staff requests that METC electronically file all environmental permits and statements associated with the construction of the proposed transmission project on Docket No. U Electronically posting this information will provide assurance to the affected residents that METC has considered and adhered to environmental regulations within the construction area. 40 Prefiled Direct Testimony of Steven J. Koster, P.E., pp Prefiled Direct Testimony of Steven J. Koster, P.E., pp See Exhibit S-9. 19

99 DIRECT TESTIMONY OF NAOMI J. SIMPSON CASE NUMBER U PART II Q. What is Staff s conclusion about METC s application pursuant to CPCN for the proposed transmission project? A. After conducting a comprehensive review and analysis of all information contained within METC s application and information provided by METC through discovery responses to all parties, Staff concludes that METC s application meets all requirements set forth in MCL , and MCL given the provisions for proposed transmission lines other than major transmission lines as identified in MCL (3). Q. Does this conclude your testimony? A. Yes

100 S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * * In the matter of the application of ) Michigan Electric Transmission Company, LLC ) for a certificate of public convenience and ) Case No. U necessity for the construction of a transmission ) line in Almena Township, Van Buren County, and ) Oshtemo Township, Kalamazoo County Michigan. ) ) EXHIBITS OF NAOMI J. SIMPSON MICHIGAN PUBLIC SERVICE COMMISSION November 30, 2012

101 Exhibit No.: S-4 Witness: Naomi J. Simpson Page No.: 1 of 4

102 Exhibit No.: S-4 Witness: Naomi J. Simpson Page No.: 2 of 4

103 Exhibit No.: S-4 Witness: Naomi J. Simpson Page No.: 3 of 4

104 Exhibit No.: S-4 Witness: Naomi J. Simpson Page No.: 4 of 4

105 Exhibit No.: S-5 Witness: Naomi J. Simpson Page No.: 1 of 1

106 Exhibit No.: S-6 Witness: Naomi J. Simpson Page No.: 1 of 2

107 Exhibit No.: S-6 Witness: Naomi J. Simpson Page No.:2 of 2

108 Exhibit No.: S-7 Witness: Naomi J. Simpson Page No.:1 of 2

109 Exhibit No.: S-7 Witness: Naomi J. Simpson Page No.:2 of 2

110 Exhibit No.: S-8 Witness: Naomi J. Simpson Page No.:1 of 1

111 Exhibit No.: S-9 Witness: Naomi J. Simpson Page No.:1 of 1

112 Exhibit No.: S-11 Witness: Naomi J. Simpson Page No.:1 of 1

113 S T A T E OF M I C H I G A N BEFORE THE MICHIGAN PUBLIC SERVICE COMMISSION * * * * In the matter of the application of ) Michigan Electric Transmission Company, LLC ) for a certificate of public convenience and ) Case No. U necessity for the construction of a transmission ) line in Almena Township, Van Buren County, and ) Oshtemo Township, Kalamazoo County, Michigan. ) ) QUALIFICATIONS AND DIRECT TESTIMONY OF STEVEN E. KULESIA MICHIGAN PUBLIC SERVICE COMMISSION November 30, 2012

114 QUALIFICATIONS OF STEVEN E. KULESIA CASE NUMBER U PART I Q. Please state your full name and business address for the record. A. My name is Steven E. Kulesia, and my business address is the Michigan Public Service Commission s (Commission) temporary work site at 4300 West Saginaw, Lansing, Michigan Q. By whom are you employed and what is your position? A. I am employed by the Commission as Manager of the Generation and Certificate of Need Section in the Electric Reliability Division (ERD). The primary responsibility of the ERD is implementation and on-going management of Public Acts 295 and 286 of 2008, which require electric and gas providers to file plans to meet renewable energy and energy efficiency standards, and also covers provisions for application to the Commission for Certificates of Necessity for new electric generation construction, acquisition or purchase capacity by utilities. The ERD also handles applications for Certificates of Public Necessity and Convenience (CPNC) to construct transmission lines pursuant to 1995 PA 30. Q. Would you please outline your educational background? A. I obtained a Bachelor of Science degree in Resource Development from the College of Agriculture and Natural Resources at Michigan State University in Since joining the Commission, I have also attended utility training programs sponsored by the National Association of Regulatory Utility Commissioners and the Institute of Public Utilities Regulatory Research and Education at Michigan State University. Q. Would you please outline your professional experience? 1

107 FERC 61,053 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

107 FERC 61,053 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION 107 FERC 61,053 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION Before Commissioners: Pat Wood, III, Chairman; Nora Mead Brownell, Joseph T. Kelliher, and Suedeen G. Kelly. Reporting By Transmission

More information

STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 ) ) ) ) ) )

STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 ) ) ) ) ) ) STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION In the Matter of Application of Duke Energy Progress, LLC, for a Certificate

More information

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2013 SESSION LAW HOUSE BILL 484

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2013 SESSION LAW HOUSE BILL 484 GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2013 SESSION LAW 2013-51 HOUSE BILL 484 AN ACT TO ESTABLISH A PERMITTING PROGRAM FOR THE SITING AND OPERATION OF WIND ENERGY FACILITIES. The General Assembly

More information

The Narragansett Electric Company d/b/a National Grid

The Narragansett Electric Company d/b/a National Grid The Narragansett Electric Company d/b/a National Grid Rhode Island Renewable Energy Growth Program Solicitation and Enrollment Process Rules for Solar (Greater than 25 kw), Wind, Hydro and Anaerobic Digester

More information

ADMINISTRATIVE CODE BOARD OF COUNTY COMMISSIONERS

ADMINISTRATIVE CODE BOARD OF COUNTY COMMISSIONERS ADMINISTRATIVE CODE BOARD OF COUNTY COMMISSIONERS CATEGORY: DEVELOPMENT/PLANNING/ZONING TITLE: TRANSPORTATION PROPORTIONATE SHARE CALCULATIONS FOR NEW DEVELOPMENT PROJECTS CODE NUMBER: AC-13-16 ADOPTED:

More information

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) ) UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION Coordination of Protection Systems for Performance During Faults and Specific Training for Personnel Reliability Standards ) ) )

More information

Title 35-A: PUBLIC UTILITIES

Title 35-A: PUBLIC UTILITIES Maine Revised Statutes Title 35-A: PUBLIC UTILITIES Chapter 97: EFFICIENCY MAINE TRUST ACT 10104. DUTIES 1. Generally. In accordance with this section and other applicable law, the trust administers and

More information

Request for Proposals and Specifications for a Community Solar Project

Request for Proposals and Specifications for a Community Solar Project Request for Proposals and Specifications for a Community Solar Project CPS Energy P.O. Box 1771 San Antonio, TX 78296-1771 October 9, 2014 PR # 10452716 INVITATION TO SUBMIT PROPOSALS 1. Introduction CPS

More information

MAINE STATE LEGISLATURE

MAINE STATE LEGISLATURE MAINE STATE LEGISLATURE The following document is provided by the LAW AND LEGISLATIVE DIGITAL LIBRARY at the Maine State Law and Legislative Reference Library http://legislature.maine.gov/lawlib Reproduced

More information

Comprehensive Plan 2009

Comprehensive Plan 2009 Comprehensive Plan 2009 2.14 PUBLIC SCHOOLS FACILITIES Goal: Coordinate and maintain a high quality education system. Collaborate and coordinate with the Okaloosa County School Board (School Board) to

More information

IC Chapter 14. Small Business Set-Aside Purchases

IC Chapter 14. Small Business Set-Aside Purchases IC 5-22-14 Chapter 14. Small Business Set-Aside Purchases IC 5-22-14-1 "Small business" Sec. 1. As used in this chapter, "small business" means a business that: (1) is independently owned and operated;

More information

PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR ELECTRIC EFFICIENCY PROJECTS PON EM

PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR ELECTRIC EFFICIENCY PROJECTS PON EM PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR ELECTRIC EFFICIENCY PROJECTS PON Opening: July 1, 2017 Closing: June 30, 2018 Revised: February 6, 2018 {P1472575.1} CONTENTS

More information

STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION

STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. E-2, SUB 1089 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION In the Matter of ) Application of Duke Energy Progress, LLC for a ) ADDITIONAL

More information

TRANSMISSION TRANSMISSION SYSTEM OPERATIONS DIVISION

TRANSMISSION TRANSMISSION SYSTEM OPERATIONS DIVISION TRANSMISSION TRANSMISSION SYSTEM OPERATIONS DIVISION Vice-President of Transmission Reporting to the President and Chief Executive Officer, the Vice-President of Transmission, is responsible for the overall

More information

MICHAEL N. FEUER CITY ATTORNEY REPORT RE:

MICHAEL N. FEUER CITY ATTORNEY REPORT RE: MICHAEL N. FEUER CITY ATTORNEY REPORT RE: R13-0351 REPORTNO.~~ ~ DEC 0 9 2013 DRAFT ORDINANCE FOR THE HAIWEE POWER PLANT PENSTOCK REPLACEMENT PROJECT REQUESTING THE LOS ANGELES CITY COUNCIL TO ESTABLISH

More information

CONNECTED CITY FREQUENTLY ASKED QUESTIONS

CONNECTED CITY FREQUENTLY ASKED QUESTIONS 1) What is the Connected City project? CONNECTED CITY FREQUENTLY ASKED QUESTIONS The Connected City Corridor is a State-initiated pilot program that is unique to Pasco County, and will be the first planned

More information

CHAPTER House Bill No. 5013

CHAPTER House Bill No. 5013 CHAPTER 2009-89 House Bill No. 5013 An act relating to transportation; amending s. 334.044, F.S.; revising the powers and duties of the Department of Transportation to provide for certain environmental

More information

NOW THEREFORE, the parties enter into the following Agreement:

NOW THEREFORE, the parties enter into the following Agreement: Interlocal Agreement Between the Board of County Commissioners of St. Johns County, Florida, City of St. Augustine, City of St. Augustine Beach, Town of Hastings and the School Board of St. Johns County,

More information

City and County of San Francisco LIFELINES COUNCIL. MEETING NOTES Meeting #9 Developing the Lifelines Council Work Program

City and County of San Francisco LIFELINES COUNCIL. MEETING NOTES Meeting #9 Developing the Lifelines Council Work Program Edwin Lee, Mayor City and County of San Francisco LIFELINES COUNCIL Thursday, September 6, 2012 2:00 PM 4:00 PM San Francisco City Hall, Room 201 Naomi Kelly, City Administrator Lifelines are the systems

More information

PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR DISTRIBUTED GENERATION PROJECTS PON EM

PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR DISTRIBUTED GENERATION PROJECTS PON EM PROGRAM OPPORTUNITY NOTICE EFFICIENCY MAINE TRUST CUSTOM INCENTIVE PROGRAM FOR DISTRIBUTED GENERATION PROJECTS PON Opening: July 1, 2017 Closing: June 30, 2018 Updated: July 1, 2017 CONTENTS SECTION 1:

More information

REQUEST FOR PROPOSAL. The City of Oneida, NY

REQUEST FOR PROPOSAL. The City of Oneida, NY REQUEST FOR PROPOSAL FOR A PERFORMANCE BASED ENERGY EFFICIENCY IMPROVEMENT PROJECT STREET LIGHTING TRANSFER TO OWNERSHIP AND LED CONVERSION For The City of Oneida, NY Letter of Public Notice The City of

More information

AGENDA REPORT. Meeting Date: December 21, 2010 Item Number: F 23

AGENDA REPORT. Meeting Date: December 21, 2010 Item Number: F 23 Meeting Date: December 21, 2010 Item Number: F 23 To: From: AGENDA REPORT Honorable Mayor & City Council Alan Schneider, Director of Project Administration Subject: APPROVAL OF THE AWARD OF A CONTRACT

More information

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION North American Electric Reliability Corporation ) ) Docket No. PETITION OF THE NORTH AMERICAN ELECTRIC RELIABILITY CORPORATION FOR

More information

The State of Interconnection in NYS:

The State of Interconnection in NYS: The State of Interconnection in NYS: Understanding the Current Situation, Navigating the New Interconnection Requirements in NY, and What s Next Melissa Kemp, NYSEIA Policy Co-Chair About NYSEIA NYSEIA

More information

Route 58 PPTA Project Finance Plan Annual Update Hillsville to Stuart Corridor. Submitted By:

Route 58 PPTA Project Finance Plan Annual Update Hillsville to Stuart Corridor. Submitted By: Route 58 PPTA Project Finance Plan Annual Update Hillsville to Stuart Corridor Submitted By: Robert P. Williams District Construction Engineer Salem District Virginia Department of Transportation Submitted

More information

VILLAGE OF VERSAILLES An Equal Opportunity Employer POSITION DESCRIPTION. Reports To: Electric Foreman FLSA Status: Non-Exempt

VILLAGE OF VERSAILLES An Equal Opportunity Employer POSITION DESCRIPTION. Reports To: Electric Foreman FLSA Status: Non-Exempt Dept./Division: Electric Employment Status: Full-Time Reports To: Electric Foreman FLSA Status: Non-Exempt QUALIFICATIONS: Any combination of training and work experience which indicates possession of

More information

205 CMR: MASSACHUSETTS GAMING COMMISSION

205 CMR: MASSACHUSETTS GAMING COMMISSION 205 CMR 119.00: PHASE 2 APPLICATION Section 119.01: Contents of the Application 119.02: Completing the Application 119.03: Evaluation of the Application by the Commission 119.01: Contents of the Application

More information

Standard Development Timeline

Standard Development Timeline FAC-001-23 Interconnection Requirements Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes

More information

Standard FAC Assessment of Transfer Capability for the Near-term Transmission Planning Horizon

Standard FAC Assessment of Transfer Capability for the Near-term Transmission Planning Horizon Standard FAC-013-2 Assessment of for the Near-term A. Introduction 1. Title: Assessment of for the Near-Term Transmission Planning Horizon 2. Number: FAC-013-2 3. Purpose: To ensure that Planning Coordinators

More information

CONSUMERS ENERGY COMPANY REQUEST FOR PROPOSALS SOLAR GENERATION PROJECTS. Bids Due: July 28, :00 noon EPT (Jackson, MI) Issued.

CONSUMERS ENERGY COMPANY REQUEST FOR PROPOSALS SOLAR GENERATION PROJECTS. Bids Due: July 28, :00 noon EPT (Jackson, MI) Issued. CONSUMERS ENERGY COMPANY REQUEST FOR PROPOSALS SOLAR GENERATION PROJECTS Bids Due: July 28, 2017 12:00 noon EPT (Jackson, MI) Issued June 5, 2017 Web Address: https://www.consumersenergy.com/residential/renewable-energy/customergeneration/electricity-sales/electric-power-notices

More information

Michigan Department of Health and Human Services LOCAL HEALTH DEPARTMENT (LHD) PLAN OF ORGANIZATION INSTRUCTIONAL GUIDE

Michigan Department of Health and Human Services LOCAL HEALTH DEPARTMENT (LHD) PLAN OF ORGANIZATION INSTRUCTIONAL GUIDE A. Legal Basis Michigan Department of Health and Human Services LOCAL HEALTH DEPARTMENT (LHD) PLAN OF ORGANIZATION INSTRUCTIONAL GUIDE The following citations are the legal basis for the Michigan Department

More information

AUSTIN ENERGY REQUEST FOR PROPOSALS (RFP) FOR THE PURCHASE OF RENEWABLE CAPACITY & ENERGY FROM RENEWABLE ENERGY RESOURCES

AUSTIN ENERGY REQUEST FOR PROPOSALS (RFP) FOR THE PURCHASE OF RENEWABLE CAPACITY & ENERGY FROM RENEWABLE ENERGY RESOURCES AUSTIN ENERGY REQUEST FOR PROPOSALS (RFP) FOR THE PURCHASE OF RENEWABLE CAPACITY & ENERGY FROM RENEWABLE ENERGY RESOURCES 1. PURPOSE A. Statement of Intent The City of Austin, Texas d/b/a Austin Energy

More information

Standard NUC Nuclear Plant Interface Coordination

Standard NUC Nuclear Plant Interface Coordination A. Introduction 1. Title: Nuclear Plant Interface Coordination 2. Number: NUC-001-2.1 3. Purpose: This standard requires coordination between Nuclear Plant Generator Operators and Transmission Entities

More information

Energy Efficiency and Economic Recovery Initiative

Energy Efficiency and Economic Recovery Initiative Alliance to Save Energy * Edison Electric Institute * Energy Future Coalition Natural Resources Defense Council Energy Efficiency and Economic Recovery Initiative December 19, 2008 To put Americans back

More information

HOME Investment Partnerships Program

HOME Investment Partnerships Program HOME Investment Partnerships Program HOMEBUYER NEW CONSTRUCTION April 2017 NOFA I. OVERVIEW The Arkansas Development Finance Authority (ADFA) hereby notifies interested Applicants of the availability of

More information

RESUME OF GEORGE JOSEPH STRAND A, Pine Knoll Apartments E Mail

RESUME OF GEORGE JOSEPH STRAND A, Pine Knoll Apartments E Mail RESUME OF GEORGE JOSEPH STRAND 415 1A, Pine Knoll Apartments E Mail Battle Creek, Michigan 49014 georgestrand96@yahoo.com (269) 924 7154 SUMMARY OF QUALIFICATIONS I have more than twenty five years of

More information

CITY OF MASON 201 West Ash St. City Hall Mason, MI Fax

CITY OF MASON 201 West Ash St. City Hall Mason, MI Fax CITY OF MASON 201 West Ash St. City Hall 517-676-9155 Mason, MI 48854-0370 Fax 517-676-1330 1. Call to Order 2. Roll Call PLANNING COMMISSION MEETING - COUNCIL CHAMBER Tuesday, December 15, 2015 6:30 p.m.

More information

December Jobless Rates Stable Throughout Southern Lower Michigan

December Jobless Rates Stable Throughout Southern Lower Michigan Bureau of Labor Market Information and Strategic Initiatives Southern Lower Michigan 201 N. Washington Sq., 5 th Floor Lansing MI 48913 Phone: 517-241-6574 Counties: Allegan, Berrien, Branch, Calhoun,

More information

STATE OF MICHIGAN DEPARTMENT OF HEALTH AND HUMAN SERVICES LANSING

STATE OF MICHIGAN DEPARTMENT OF HEALTH AND HUMAN SERVICES LANSING RICK SNYDER GOVERNOR STATE OF MICHIGAN DEPARTMENT OF HEALTH AND HUMAN SERVICES LANSING NICK LYON DIRECTOR September 12, 2017 Dear Health Officer: We are pleased to share the enclosed information regarding

More information

PHILADELPHIA ENERGY AUTHORITY

PHILADELPHIA ENERGY AUTHORITY PHILADELPHIA ENERGY AUTHORITY REQUEST FOR QUALIFICATIONS for A Heating, Cooling and Power Supplier for the Public Safety Services Campus 2015 Issued by: Philadelphia Energy Authority Philadelphia Energy

More information

CITY OF MASON 201 West Ash St. City Hall Mason, MI Fax

CITY OF MASON 201 West Ash St. City Hall Mason, MI Fax CITY OF MASON 201 West Ash St. City Hall 517-676-9155 Mason, MI 48854-0370 Fax 517-676-1330 1. Call to Order 2. Roll Call PLANNING COMMISSION MEETING - COUNCIL CHAMBER Tuesday, January 12, 2016 6:30 p.m.

More information

Invitation to Submit Expression of Interest and Proposal

Invitation to Submit Expression of Interest and Proposal REPÚBLICA DEMOCRÁTICA DE TIMOR LESTE MINISTÉRIO DAS FINANCAS Invitation to Submit Expression of Interest and Proposal I. INTRODUCTION 1. The Government of Timor-Leste is inviting interested eligible Power

More information

SENATE, No. 876 STATE OF NEW JERSEY. 218th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2018 SESSION

SENATE, No. 876 STATE OF NEW JERSEY. 218th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2018 SESSION SENATE, No. STATE OF NEW JERSEY th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 0 SESSION Sponsored by: Senator STEPHEN M. SWEENEY District (Cumberland, Gloucester and Salem) Senator STEVEN V. OROHO District

More information

Office of Business and Financial Services Procurement and Contracts Division Section SUBJECT: PROCUREMENT OF CONSTRUCTION SERVICES

Office of Business and Financial Services Procurement and Contracts Division Section SUBJECT: PROCUREMENT OF CONSTRUCTION SERVICES 2510.8 SUBJECT: PROCUREMENT OF CONSTRUCTION SERVICES :1 OBJECTIVE: To establish a uniform policy and procedure for the acquisition of construction services for the City of Orlando (City), including, but

More information

July 1, 2006 Revision 2

July 1, 2006 Revision 2 Self-Generation Incentive Program Modification Guideline (PMG) July 1, 2006 Revision 2 TABLE OF CONTENTS TABLE OF CONTENTS...i 1. GUIDELINE BACKGROUND & PURPOSE...1 1.1. Background...1 1.2. Purpose...1

More information

Applications accepted through 9/15/2016 by 5:00 PM Eastern Time

Applications accepted through 9/15/2016 by 5:00 PM Eastern Time Fuel NY - Permanent Generator Initiative Program Opportunity Notice (PON) 3256 $ 12,000,000 available Applications accepted through 9/15/2016 by 5:00 PM Eastern Time INITIATIVE SUMMARY The New York State

More information

130 FERC 61,211 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

130 FERC 61,211 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION 130 FERC 61,211 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION Before Commissioners: Jon Wellinghoff, Chairman; Marc Spitzer, Philip D. Moeller, and John R. Norris. Mandatory Reliability

More information

Nassau County 2030 Comprehensive Plan. Public School Facilities Element (PSF) Goals, Objectives and Policies. Goal

Nassau County 2030 Comprehensive Plan. Public School Facilities Element (PSF) Goals, Objectives and Policies. Goal (PSF) Goal Work closely with the School District of Nassau County to ensure a high quality, fiscally sound public school system which meet the needs of Nassau County s population by providing and maintaining

More information

The University of Texas at San Antonio

The University of Texas at San Antonio The University of Texas at San Antonio Job Description Job Title: Electrician III Code: 15211 Salary Grade: 60 FLSA Status: Non-Exempt Department/Division: Office of Facilities Reports To: Maintenance

More information

Local Emergency Planning Committee Responsibilities

Local Emergency Planning Committee Responsibilities Local Emergency Planning Committee Responsibilities A. AUTHORITY FOR LOCAL EMERGENCY PLANNING COMMITTEES 42 U.S.C. 11001-11050 The Emergency Planning and Community-Right-to-Know Act require the establishment

More information

INFORMATION BULLETIN OPERATING PERMITS

INFORMATION BULLETIN OPERATING PERMITS OPERATING PERMITS This guide supplements Directive NO: D-E3 070801 7 revised on May 4, 2015. The following document provides guidance on the application of policy for BCSA. Please check with municipal

More information

Northeast Power Coordinating Council, Inc. Regional Standards Process Manual (RSPM)

Northeast Power Coordinating Council, Inc. Regional Standards Process Manual (RSPM) DRAFT FOR REVIEW & COMMENT Last Updated 5/15/13 Note to reviewers: Links to NERC website and process flow charts will be finalized for the final review. Northeast Power Coordinating Council, Inc. Regional

More information

Washington Headquarters Services Military Construction, Defense-Wide FY 2010 Budget Estimates ($ in thousands)

Washington Headquarters Services Military Construction, Defense-Wide FY 2010 Budget Estimates ($ in thousands) Military Construction, Defense-Wide FY 2010 Budget Estimates ($ in thousands) New/ Authorization Approp. Current Page State/Installation/Project Request Request Mission No. Virginia Pentagon Reservation

More information

COUNTY OF SANTA BARBARA

COUNTY OF SANTA BARBARA COUNTY OF SANTA BARBARA REQUEST FOR PROPOSALS FOR STRATEGIC ENERGY PLANNING SERVICES Question Deadline: Contact Person: Submittal Deadline: Submittal Location: Friday, January 19, 2018, 5 pm PST Jennifer

More information

Florida Job Growth Grant Fund Public Infrastructure Grant Proposal

Florida Job Growth Grant Fund Public Infrastructure Grant Proposal Florida Job Growth Grant Fund Public Infrastructure Grant Proposal Proposal Instructions: The Florida Job Growth Grant Fund Proposal (this document) must be completed by the governmental entity applying

More information

Title 32: PROFESSIONS AND OCCUPATIONS

Title 32: PROFESSIONS AND OCCUPATIONS Title 32: PROFESSIONS AND OCCUPATIONS Chapter 17: ELECTRICIANS Table of Contents Subchapter 1. GENERAL PROVISIONS... 3 Section 1101. DEFINITIONS... 3 Section 1102. EXCEPTIONS... 4 Section 1102-A. EXCEPTIONS

More information

Commercial Scale. Direct Ownership-Application. Renewable Energy Projects over 10kW. Commercial Block program details can be found at:

Commercial Scale. Direct Ownership-Application. Renewable Energy Projects over 10kW. Commercial Block program details can be found at: Commercial Scale Direct Ownership-Application Renewable Energy Projects over 10kW Commercial Block program details can be found at: http://commerceri.com/finance-business/renewable-energy-fund/commercial-scale-projects/

More information

Request for Proposal NYISO SGIG DBA RFP #: 12-7 NYISO DOE Smart Grid Investment Grant - Database Administrator Issued: February 2, 2012

Request for Proposal NYISO SGIG DBA RFP #: 12-7 NYISO DOE Smart Grid Investment Grant - Database Administrator Issued: February 2, 2012 10 Krey Boulevard Rensselaer, NY 12144 Request for Proposal NYISO SGIG DBA RFP #: 12-7 NYISO DOE Smart Grid Investment Grant - Database Administrator Issued: February 2, 2012 I. INTRODUCTION A. Overview

More information

Program Plan For the Energy Efficiency and Renewable Energy Technology Account Under New York s Clean Air Interstate Rules (CAIR)

Program Plan For the Energy Efficiency and Renewable Energy Technology Account Under New York s Clean Air Interstate Rules (CAIR) Program Plan For the Energy Efficiency and Renewable Energy Technology Account Under New York s Clean Air Interstate Rules (CAIR) New York Battery and Energy Storage Technology Consortium Originally prepared

More information

Request for Proposals (RFP) for Electric Bicycle Manufacturers and Shops for the Intermountain Drives Electric Program and Live Electric Program

Request for Proposals (RFP) for Electric Bicycle Manufacturers and Shops for the Intermountain Drives Electric Program and Live Electric Program Request for Proposals (RFP) for Electric Bicycle Manufacturers and Shops for the Intermountain Drives Electric Program and Live Electric Program Administered by Utah Clean Energy Original Issue: August

More information

Florida Job Growth Grant Fund Public Infrastructure Grant Proposal

Florida Job Growth Grant Fund Public Infrastructure Grant Proposal Florida Job Growth Grant Fund Public Infrastructure Grant Proposal Proposal Instructions: The Florida Job Growth Grant Fund Proposal (this document) must be completed by the governmental entity applying

More information

REQUEST FOR PROPOSALS

REQUEST FOR PROPOSALS Community Development Department Planning & Zoning Division REQUEST FOR PROPOSALS COMBINED ACTIVE TRANSPORTATION/ SAFE ROUTES TO SCHOOL PLAN State Project No. ATPL-5169 (048) RELEASE DATE: SEPTEMBER 23,

More information

The Narragansett Electric Company d/b/a National Grid

The Narragansett Electric Company d/b/a National Grid The Narragansett Electric Company d/b/a National Grid Rhode Island Renewable Energy Growth Program Solicitation and Enrollment Process Rules for Small Scale Solar Projects Effective Date: April 1, 2018

More information

Appendix 5A. Organization Registration and Certification Manual

Appendix 5A. Organization Registration and Certification Manual Appendix 5A Organization Registration and Certification Manual Effective: October 4, 2013 www.nerc.com Table of Contents Section I Executive Summary... 1 Overview... 1 To Whom Does This Document Apply?...

More information

Wyoming Public Service Commission (WPSC) Biennium Strategic Plan

Wyoming Public Service Commission (WPSC) Biennium Strategic Plan Wyoming Public Service Commission (WPSC) 2017-2018 Biennium Strategic Plan Results Statement Wyoming state government is a responsible steward of State assets and effectively responds to the needs of residents

More information

PUBLIC SCHOOL FACILITIES ELEMENT:

PUBLIC SCHOOL FACILITIES ELEMENT: PUBLIC SCHOOL FACILITIES ELEMENT: Goals, Objectives and Policies Goal 1: Public School Concurrency. It is a GOAL of the Town of Jupiter to provide for future availability of public school facilities consistent

More information

Upper Darby Township 100 Garrett Rd. Upper Darby, PA 19082

Upper Darby Township 100 Garrett Rd. Upper Darby, PA 19082 Upper Darby Township 100 Garrett Rd. Upper Darby, PA 19082 REQUEST FOR PROPOSAL BACKGROUND The Aronimink Station area is a mixed use neighborhood commercial area located at the intersection of Ferne Blvd.

More information

Multifamily Affordable Solar Housing. Semi Annual Progress Report. July 31, 2013

Multifamily Affordable Solar Housing. Semi Annual Progress Report. July 31, 2013 Multifamily Affordable Solar Housing Semi Annual Progress Report July 31, 2013 Table of Contents 1. Executive Summary... 2 2. Background... 3 2.1. Incentive Types: Track 1 (A and B) and Track 2... 4 Table

More information

ISABELLA COUNTY REQUEST FOR PROPOSALS COMMISSION ON AGING CATV AND HEADEND EQUIPMENT

ISABELLA COUNTY REQUEST FOR PROPOSALS COMMISSION ON AGING CATV AND HEADEND EQUIPMENT ISABELLA COUNTY REQUEST FOR PROPOSALS COMMISSION ON AGING CATV AND HEADEND EQUIPMENT ISSUED BY ISABELLA COUNTY BOARD OF COMMISSIONERS ISSUE DATE: February 4, 2008 ISABELLA COUNTY REQUEST FOR PROPOSALS

More information

AN ORDINANCE TO AMEND CERTAIN PROVISIONS IN THE RAPID CITY ELECTRICAL CODE BY AMENDING SECTION OF THE RAPID CITY MUNICIPAL CODE

AN ORDINANCE TO AMEND CERTAIN PROVISIONS IN THE RAPID CITY ELECTRICAL CODE BY AMENDING SECTION OF THE RAPID CITY MUNICIPAL CODE Ordinance No. 6105 AN ORDINANCE TO AMEND CERTAIN PROVISIONS IN THE RAPID CITY ELECTRICAL CODE BY AMENDING SECTION 15.16.020 OF THE RAPID CITY MUNICIPAL CODE WHEREAS, the City of Rapid City has adopted

More information

REQUEST FOR QUALIFICATIONS MUNICIPAL ENGINEERING SERVICES

REQUEST FOR QUALIFICATIONS MUNICIPAL ENGINEERING SERVICES CITY OF CASTLE HILLS TEXAS REQUEST FOR QUALIFICATIONS MUNICIPAL ENGINEERING SERVICES PROPOSED AWARD SCHEDULE December 6, 2017 December 20, 2017 January 16, 2018 January 23, 2018 January 30, 2018 February

More information

Request for Proposals for Comprehensive Market Analysis & Strategies for Barry County, Michigan

Request for Proposals for Comprehensive Market Analysis & Strategies for Barry County, Michigan Request for Proposals for Comprehensive Market Analysis & Strategies for Barry County, Michigan Section One Introduction and Instructions 1.01 Purpose of the RFP This Request for Proposals (RFP) is issued

More information

DEP has three main regulatory chapters that relate to pipeline construction.

DEP has three main regulatory chapters that relate to pipeline construction. Testimony of Patrick McDonnell, Secretary Pennsylvania Department of Environmental Protection Hearing on Pipeline Safety and Development House Majority Policy Committee July 17, 2018 Good morning, Chairman

More information

Managing CDBG. A Guidebook for Grantees on Subrecipient Oversight. U.S. Department of Housing and Urban Development

Managing CDBG. A Guidebook for Grantees on Subrecipient Oversight. U.S. Department of Housing and Urban Development U.S. Department of Housing and Urban Development Office of Community Planning and Development Community Development Block Grant Program Managing CDBG A Guidebook for Grantees on Subrecipient Oversight

More information

SunZia Southwest Transmission Project. September. Project Update for the Board of Socorro County Commissioners February 28, 2017.

SunZia Southwest Transmission Project. September. Project Update for the Board of Socorro County Commissioners February 28, 2017. SunZia Southwest Transmission Project SunZia Southwest Transmission Project Project Update for the Board of Socorro County Commissioners February 28, 2017 SUNZIA SOUTHWEST TRANSMISSION PROJECT FEBRUARY

More information

CENTRAL MUNICIPAL POWER AGENCY/SERVICES

CENTRAL MUNICIPAL POWER AGENCY/SERVICES CENTRAL MUNICIPAL POWER AGENCY/SERVICES 2017 Request for Solar Proposals August 4, 2017 On Behalf of Springfield Public Utilities Contact: Kyle Haemig, Resource Planner/Economist kyleh@cmpasgroup.org 763-710-3934

More information

N.J.A.C. 5: New Jersey Register, Vol. 49 No. 12, June 19, 2017

N.J.A.C. 5: New Jersey Register, Vol. 49 No. 12, June 19, 2017 -1.1 SUBCHAPTER 1. GENERAL PROVISIONS 5:12-1.1 Title and citation This regulation shall be known and may be cited as N.J.A.C. 5:12, Ski Lifts. Page 2 of 30 N.J.A.C. 5:12-1.2 SUBCHAPTER 1. GENERAL PROVISIONS

More information

LAND PARTNERSHIPS GRANT PROGRAM. PROGRAM GUIDELINES April 2018

LAND PARTNERSHIPS GRANT PROGRAM. PROGRAM GUIDELINES April 2018 LAND PARTNERSHIPS GRANT PROGRAM PROGRAM GUIDELINES April 2018 Cumberland County Planning Department 310 Allen Road, Suite 101 Carlisle, PA 17013 (717) 240-5362 www.ccpa.net/landpartnerships TABLE OF CONTENTS

More information

Brooke County Access I, L.L.C., Brooke County Access Project Monthly Pre-filing Status Report #5 Docket No. PF

Brooke County Access I, L.L.C., Brooke County Access Project Monthly Pre-filing Status Report #5 Docket No. PF April 26, 2018 Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426 Re: Brooke County Access I, L.L.C., Brooke County Access Project Monthly Pre-filing

More information

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 865

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 865 CHAPTER 2017-42 Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 865 An act relating to the Department of Transportation; creating s. 316.0898, F.S.; requiring

More information

Synopsis of Revised Changes to DCA s Rules for Developments of Regional Impact

Synopsis of Revised Changes to DCA s Rules for Developments of Regional Impact The Georgia Planning Act, passed by the General Assembly in 1989, charged the Georgia Department of Community Affairs with administering the State s comprehensive planning program. 1 That legislation assigned

More information

SOUTH HEIDELBERG TOWNSHIP - SUNOCO MARINER EAST II PIPELINE TALKING POINTS

SOUTH HEIDELBERG TOWNSHIP - SUNOCO MARINER EAST II PIPELINE TALKING POINTS SOUTH HEIDELBERG TOWNSHIP - SUNOCO MARINER EAST II PIPELINE TALKING POINTS WHAT The overall pipeline project involves construction of two new, larger pipelines to convey natural gas liquids. Since the

More information

Summary of AV START Act (S.1885)

Summary of AV START Act (S.1885) Summary of AV START Act (S.1885) Section 2: Definitions Defines terms automated driving system, dedicated highly automated driving system, and highly automated vehicle, but definitions fail to include

More information

Energy Optimization Plan

Energy Optimization Plan City of Stephenson Department of Public Works In cooperation with the Michigan Electric Cooperative Association Energy Optimization Plan 2012-2015 Descriptions Energy Efficiency Optimization Plan 2012-2015

More information

DECISION OF THE CAPE COD COMMISSION

DECISION OF THE CAPE COD COMMISSION Date: To: From: Re: Applicant: Michael D. Ford, Esq. P.O. Box 665 Harwich, MA 02671 Cape Cod Commission Development of Regional Impact Hardship Exemption Cape Cod Commission Act, Section 23 Couto Management

More information

PIPES Act of 2006 Redline of 49 USC CHAPTER SAFETY 49 USC CHAPTER SAFETY 01/19/04 CHAPTER SAFETY

PIPES Act of 2006 Redline of 49 USC CHAPTER SAFETY 49 USC CHAPTER SAFETY 01/19/04 CHAPTER SAFETY 49 USC CHAPTER 601 - SAFETY 01/19/04 CHAPTER 601 - SAFETY Sec. 60101. Definitions. 60102. Purpose and general authority. 60103. Standards for liquefied natural gas pipeline facilities. 60104. Requirements

More information

Generator Interconnection Impact Study Report Bladen County, NC 75.0 MW Solar Farm Queue #377

Generator Interconnection Impact Study Report Bladen County, NC 75.0 MW Solar Farm Queue #377 Generator Impact Study Report Bladen County, NC 75.0 Solar Farm Queue #377 Table of Contents 1 PURPOSE... 3 2 ASSUMPTIONS... 3 3 RESULTS... 4 3.1 Power-flow Analysis Results... 4 3.2 Stability Analysis

More information

RECOVERY ACT FINANCIAL ASSISTANCE FUNDING OPPORTUNITY ANNOUNCEMENT. U. S. Department of Energy Office of Electricity Delivery and Energy Reliability

RECOVERY ACT FINANCIAL ASSISTANCE FUNDING OPPORTUNITY ANNOUNCEMENT. U. S. Department of Energy Office of Electricity Delivery and Energy Reliability RECOVERY ACT FINANCIAL ASSISTANCE FUNDING OPPORTUNITY ANNOUNCEMENT U. S. Department of Energy Office of Electricity Delivery and Energy Reliability Smart Grid Investment Grant Program Funding Opportunity

More information

RULES OF THE TENNESSEE DEPARTMENT OF HUMAN SERVICES ADMINISTRATIVE PROCEDURES DIVISION CHAPTER CHILD CARE AGENCY BOARD OF REVIEW

RULES OF THE TENNESSEE DEPARTMENT OF HUMAN SERVICES ADMINISTRATIVE PROCEDURES DIVISION CHAPTER CHILD CARE AGENCY BOARD OF REVIEW RULES OF THE TENNESSEE DEPARTMENT OF HUMAN SERVICES ADMINISTRATIVE PROCEDURES DIVISION CHAPTER 1240-5-13 CHILD CARE AGENCY BOARD OF REVIEW TABLE OF CONTENTS 1240-5-13-.01 Purpose and Scope 1240-5-13-.05

More information

Northline Solar Project

Northline Solar Project Date: June 11, 2015 Qualified Applicant: Invenergy LLC 120 Front Street East, Suite 201 Toronto, ON M5A 4L9 Registered Proponent: Northline Solar Energy Partnership Email: northlineinfo@invenergyllc.com

More information

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION Tennessee Gas Pipeline Company, L.L.C. Docket No. PF14-22-000 NOTICE OF INTENT TO PREPARE AN ENVIRONMENTAL IMPACT STATEMENT FOR THE PLANNED

More information

Alert. Changes to Licensed Scope of Practice of Physician s Assistants in Michigan. msms.org. Participating Physician. Practice Agreement

Alert. Changes to Licensed Scope of Practice of Physician s Assistants in Michigan. msms.org. Participating Physician. Practice Agreement Alert Changes to Licensed Scope of Practice of Physician s Assistants in Michigan By Patrick J. Haddad, JD, Kerr, Russell and Weber, PLC, MSMS Legal Counsel FEBRUARY 24, 2017 Public Act 379 of 2016, effective

More information

REVISOR RSI/BR RSI-ENERGY

REVISOR RSI/BR RSI-ENERGY 1.1 Section 1. Minnesota Statutes 2017 Supplement, section 116C.779, subdivision 1, is 1.2 amended to read: 1.3 Subdivision 1. Renewable development account. (a) The renewable development 1.4 account is

More information

History. Acts 1985, No. 876, 2; Acts 1993, No. 322, 1; 1993, No. 440, 1. A.S.A. 1947,

History. Acts 1985, No. 876, 2; Acts 1993, No. 322, 1; 1993, No. 440, 1. A.S.A. 1947, Arkansas Code 8-2-201. Title. April 7, 1998 8-2-201. Title. This subchapter may be called the "State Environmental Laboratory Certification Program Act." History. Acts 1985, No. 876, 1; A.S.A. 1947, 82-1993.

More information

Proposals. For funding to create new affordable housing units in Westport, MA SEED HOUSING PROGRAM. 3/28/2018 Request for

Proposals. For funding to create new affordable housing units in Westport, MA SEED HOUSING PROGRAM. 3/28/2018 Request for 3/28/2018 Request for Proposals For funding to create new affordable housing units in Westport, MA SEED HOUSING PROGRAM TOWN OF WESTPORT SEED HOUSING PROGRAM WESTPORT, MA TABLE OF CONTENTS 1 General Information

More information

Richland County Local Emergency Planning Committee (LEPC) By-Laws

Richland County Local Emergency Planning Committee (LEPC) By-Laws Richland County Local Emergency Planning Committee (LEPC) By-Laws ARTICLE I: Section 1: General Provisions/Rules of Operation Preamble The Local Emergency Planning Committee (LEPC) serves Richland County,

More information

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION Tennessee Gas Pipeline Company, L.L.C. National Fuel Gas Supply Corporation Docket No. CP14-88-000 Docket No. NOTICE OF INTENT TO PREPARE AN

More information

NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS METROPOLITAN PLANNING ORGANIZATION REQUEST FOR PROPOSALS

NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS METROPOLITAN PLANNING ORGANIZATION REQUEST FOR PROPOSALS NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS METROPOLITAN PLANNING ORGANIZATION REQUEST FOR PROPOSALS CITY OF CEDAR HILL CITY CENTER TRANSIT-ORIENTED DEVELOPMENT PLAN August 19, 2011 REQUEST FOR PROPOSALS

More information

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION Adelphia Gateway, LLC Docket No. CP18-46-000 NOTICE OF INTENT TO PREPARE AN ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ADELPHIA GATEWAY PROJECT,

More information